West Bengal Power Development Corporation Limited has published Railway In Plant Railway Signaling System At Sgtpp , Murshidabad. Submission Date for this Tender is 03-03-2021. Bolts Tenders in Sagardighi Thermal Power Project West Bengal. Bidders can get complete Tender details and download the document.
Name of Work: Railway in plant Signaling Signal at SgTPP, Murshidabad | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Scope of work and price bid | |||
2 | 1.01 | Railway in plant Signaling Signal at SgTPP, Murshidabad | item1 | 24 | Months |
3 | 1.02 | End termination cable alongwith kits.\nEnd termination of 3CX95Sq.mm 11KV grade Al Cable along\nwith supply of Jointing Kits(Heat shrinkable of\nMake:3M/Raychem)complete with all accessories including lugs. | item2 | 27 | Number |
4 | 1.03 | Laying of HT Cable on Existing\nCable Tray/Trestle. | item3 | 500 | Meter |
5 | 1.04 | Boring along with supply & laying\nBoring along with supply & laying of HDPE pipe(110MM\ndia.)towards passage of 3Cx95Sq.mm ,Al XLPE armoured Cable.. | item4 | 150 | Meter |
6 | 1.05 | Fitting ,fixing & fabrication\nof Cable Riser Suitable for 3cx95 Sq.mm Al Armoured Cable\nalong with supply of GI Pipe (100mm dia G.I. angle, flat\n,Nuts,bolts as per requirements.. | item5 | 78 | Number |
7 | 1.06 | Fixing of Cast Iron Cable route marker on concrete foundation along with supply. | item6 | 50 | Number |
8 | 1.07 | Fitting & fixing of 12KV gapless LA\nalong with supply of LA and other accessories required for the\nJob. | item7 | 3 | Number |
9 | 1.08 | Fitting & fixing of 900mm CD Polymer\nComposite Pin Insulator along with supply of same and other\naccessories required for the job. | item8 | 48 | Number |
10 | 1.09 | Erection of DP Structure with 9M PCC\nPole including Cement Concrete along with supply of PCC\npoles(10nos of 9Mtr),G.I nuts, bolts, Angles, Flats etc.as per\nrequirements. The excavated earth pit shall be filled with shifted\nsoil and rammed properly. Pole structure should be double earthed\nwith 6x50mm GI strip and earth pipe. | item9 | 5 | Number |
11 | 1.1 | Erection of 4P Structure with 9M PCC\nPole including Cement Concrete along with supply of PCC\npoles(4nos of 9Mtr),G.I nuts, bolts, Angles, Flats etc.as per\nrequirements. The excavated earth pit shall be filled with shifted\nsoil and rammed properly. Pole structure should be double earthed\nwith 6x50mm GI strip and earth pipe. | item10 | 2 | Number |
12 | 1.11 | Erection of 400A,11KV TPGO Isolator\nalong with supply of isolator,GI angle/Channel/Flats/Bolts/Nuts etc.\nas per requirements | item11 | 3 | Number |
13 | 1.12 | Eathing of 4P,DP Strutcres by Suitable\nearth by using GI earth pipe (50mm dia,3mtr.long) including\nconnection with structures through 50x6mm GI Flat along with\nsupply of GI Pipe, flats & all others accessories as per\nrequirement. | item12 | 15 | Number |
14 | 1.13 | Jumpering /Busbar formation at 4P/DP\nStructures as Per requirements through ACSR\n100sq.mm(DOG)along with supply of same. | item13 | 400 | Meter |
15 | 1.14 | Fitting & fixing of P.G clamp\nfor DOG along with supply of same. | item14 | 60 | Number |
16 | 1.15 | Fitting & fixing of danger board. | item15 | 14 | Number |
17 | 1.16 | Telephone cable joint upto 20 pairs (underground) with jointing kits. | item16 | 60 | Number |
18 | 1.17 | Telephone cable joint upto 50 pairs (underground) with jointing kits. | item17 | 60 | Number |
19 | 1.18 | Telephone cable joint upto 100 pairs (underground) with jointing kits. | item18 | 20 | Number |
20 | 1.19 | OFC cable laying including boring of earth below 1.5 Mtr and laying of 6 core optical fiber through 50 mm hose pipe and backfilling of earth after cable laying. | item19 | 1500 | meter |
21 | 1.2 | CAT6 Cable Laying. Over Cable Tray/Floor/Wall etc. | item20 | 7500 | meter |
22 | 1.21 | IO box mount, crimping and dismantling for CAT6 & Telephone Cable. | item21 | 400 | Number |
23 | 1.22 | Underground telephone cable laying under bricks and 0.75 mtr below the surface.(For new line at SgTPP Township and Plant area.) | item22 | 6000 | meter |
24 | 1.23 | Road boring for lay of Telephone cable with 75 mm GI Pipe | item23 | 160 | Meter |
25 | 1.24 | Installation/shifting wireless communication device at 9 mtrs/21 mtrs/24 mtrs/ GBT Tower. | item24 | 50 | Number |
26 | 1.25 | Telephone cable jointing overhead up to 10 pairs with jointing kits | item25 | 40 | Number |
27 | 1.26 | Telephone cable jointing underground up to 10 pairs with jointing kits | item26 | 20 | Number |
28 | 1.27 | Electrical casing/PVC pipe wiring with cable | item27 | 1300 | Meter |
29 | 1.28 | Erection of Power board comprises of 3 nos switch, 3 nos plug, 1no. Fuse & 1 no. indication lamp. | item28 | 40 | Number |
30 | 1.29 | 3X2.5 Sq. mm pwer cable laying over the earth surface/cable tray/ wall/using saddle | item29 | 5500 | Meter |
31 | 1.3 | Line checking of intercom connection | item30 | 2500 | Number |
32 | 1.31 | Telephone exchange room cleaning. | item31 | 48 | Number |
33 | 1.32 | Paging handset checking /replacement /shifting(Unit#1,2,3,4) | item32 | 300 | Number |
34 | 1.33 | Paging Line checking / trouble shooting of Paging set(Unit#1,2,3,4) | item33 | 300 | Number |
35 | 1.34 | Loud speaker/Paging set installation at Power House and Conference Rooms. | item34 | 200 | Number |
36 | 1.35 | Caping casing fixing with supply of material Caping, casing material supplied must be of standard quality. | item36 | 1500 | Meter |
37 | 1.36 | Rate for supply of 50 mm PLB pipe (For OFC cable laying/CAT 6 cable laying.) | item37 | 3000 | Meter |
38 | 1.37 | 4U/6U Rack erection | item38 | 40 | Number |
39 | 1.38 | Fitting of 3/8 inch dia Copper tube per meter for Split/Window/Standing type AC m/c including supply of Copper Tube & Insulation. | item39 | 50 | Nos |
40 | 1.39 | Fitting of Copper tube Insulation per meter with supply. | item40 | 200 | Nos |
41 | 1.4 | Replacement of Suction Valve for Split/Window/Standing type AC m/c including supply. | item41 | 2 | Nos |
42 | 1.41 | Replacement of Discharge Valve for Split/Window/Standing/Ductable type AC m/c including supply. | item42 | 2 | Nos |
43 | 1.42 | Replacement of Thermostat Switch for 1 T / 1.5 T / 2 T capacity Window/Split type AC m/c including supply. | item43 | 2 | Nos |
44 | 1.43 | Replacement of Thermostat Switch for 3 T capacity Split type AC m/c including supply. | item44 | 1 | Nos |
45 | 1.44 | Replacement of Thermostat Switch for 3 T capacity ductable type AC m/c including supply. | item45 | 1 | Nos |
46 | 1.45 | Replacement of Thermostat Switch for 2 T capacity Standing type AC m/c including supply. | item46 | 1 | Nos |
47 | 1.46 | Replacement of Thermostat Switch for 4 T capacity Standing type AC m/c including supply. | item47 | 1 | Nos |
48 | 1.47 | Replacement of Thermostat Switch for 3 T capacity Standing type AC m/c including supply. | item48 | 1 | Nos |
49 | 1.48 | Fabrication of Frame with MS Flat, Angles, nut-bolts and then Erection & Mounting the Frame on wall for protection of 1 T / 1.5 T / 2 T capacity Window type AC m/c, with supply of materials. | item49 | 6 | Nos |
50 | 1.49 | Fabrication of Frame with MS Flat, Angles, Erection & Mounting on wall for protection of 1 T / 1.5 T / 2 T capacity Split type AC Outdoor Unit with supply of materials. | item50 | 12 | Nos |
51 | 1.5 | Replacement of Total Copper Condenser coil for I T / 1.5T Window type AC with supply. | item51 | 3 | No |
52 | 1.51 | Replacement of Total Copper Condenser coil for 1 T / 1.5T split type AC with supply. | item52 | 3 | No |
53 | 1.52 | Replacement of Total Copper Condenser coil for 2 T window type AC with supply. | item53 | 3 | No |
54 | 1.53 | Replacement of Total Copper Condenser coil for 2 T split type AC with supply. | item54 | 3 | No |
55 | 1.54 | Replacement of Total Copper Condenser coil for 3 T split type AC with supply. | item56 | 1 | No |
56 | 1.55 | Replacement of Total Copper Condenser coil for 3 T Ductable type AC with supply. | item57 | 1 | No |
57 | 1.56 | Replacement of Total Copper Condenser coil for 4 T split type AC with supply. | item58 | 1 | No |
58 | 1.57 | Replacement of Total Copper Cooling coil for 1 T/ 1.5T Window type AC with supply. | item59 | 1 | No |
59 | 1.58 | Replacement of Total Copper Cooling coil for 1 T / 1.5T split type AC with supply. | item60 | 2 | No |
60 | 1.59 | Replacement of Total Copper Cooling coil for 2 T window type AC with supply. | item61 | 1 | No |
61 | 1.6 | Replacement of Total Copper Cooling coil for 4T Standing type AC with supply. | item62 | 1 | No |
62 | 1.61 | Replacement of Total Copper Cooling coil for 2 T split type AC with supply. | item63 | 1 | No |
63 | 1.62 | Replacement of Total Copper Cooling coil for 3 T split type AC with supply. | item64 | 1 | No |
64 | 1.63 | Replacement of Total Copper Cooling coil for 3 T ductable type AC with supply. | item65 | 1 | No |
65 | 1.64 | Repair of Copper Condenser coil for 1T / 1.5 T / 2 T Window type AC. | item66 | 1 | No |
66 | 1.65 | Repair of Copper cooling coil for 1T / 1.5 T / 2 T / 3 T split type AC. | item67 | 1 | No |
67 | 1.66 | Replacement of Runner of 4 T stading type AC with supply. | item68 | 1 | Nos |
68 | 1.67 | Replacement of Runner of 1T / 1.5 T / 2 T Split type AC with supply. | item69 | 2 | Nos |
69 | 1.68 | Replacement of Runner of 3 T Split type AC with supply. | item70 | 1 | Nos |
70 | 1.69 | Replacement of Runner of 3 T Ductable type AC with supply. | item71 | 1 | Nos |
71 | 1.7 | Replacement of Runner of 1 T / 1.5 T / 2 T Window type AC with supply. | item72 | 2 | Nos |
72 | 1.71 | Replacement of Runner for 7.5 T Ductable type AC with supply. | item73 | 1 | No |
73 | 1.72 | Replacement of Fan/Blower Motor for window type AC 1 T Capacity with supply. | item74 | 2 | Nos |
74 | 1.73 | Replacement of Fan/Blower Motor for window AC 1.5 T / 2 T Capacity with supply. | item75 | 10 | Nos |
75 | 1.74 | Replacement of Fan/Blower Motor for Split AC 1 T Capacity with supply. | item76 | 5 | Nos |
76 | 1.75 | Replacement of Fan/Blower Motor for Split AC 1.5 T / 2 T Capacity with supply. | item77 | 10 | Nos |
77 | 1.76 | Replacement of Fan/Blower Motor for Standing AC 2 T Capacity with supply. | item78 | 2 | Nos |
78 | 1.77 | Replacement of Fan/Blower Motor for Standing AC 4 T Capacity with supply. | item79 | 2 | Nos |
79 | 1.78 | Replacement of Fan/Blower Motor for Split AC 3 T Capacity with supply. | item80 | 1 | No |
80 | 1.79 | Replacement of Fan/Blower Motor for Ductable AC 3 T Capacity with supply. | item81 | 1 | No |
81 | 1.8 | Replacement of cooling Motor (3 phase, 3 HP) for Ductable AC of 7.5 T Capacity with supply. | item83 | 1 | No |
82 | 1.81 | Replacement of Starting Relay for 1 T / 1.5 T / 2 T Split/Window AC with supply. | item85 | 6 | Nos |
83 | 1.82 | Replacement of Selector Switch of Split/Window AC with supply. | item86 | 2 | Nos |
84 | 1.83 | Installation/Replacement of 1 POLE MCB at AC power line without supply of MCB. | item87 | 5 | Nos |
85 | 1.84 | Installation/Replacement of 2 pole MCB at AC power line with supply of MCB, Make Siemens, Rating 25 Amp | item88 | 5 | Nos |
86 | 1.85 | Installation/Replacement of 3 pole MCB at AC power line with supply of MCB, Make Siemens, Rating 25 Amp | item89 | 2 | Nos |
87 | 1.86 | Extension of Electrical wiring for AC machine with 4 sq mm Copper wire with earthing in PVC casing / pipe per meter with supply of the wire, casing etc. wiring materials per meter. | item90 | 20 | Nos |
88 | 1.87 | Replacement of Starting/Running Capacitor with supply for 1 T Window/Split type AC. | item91 | 10 | Nos |
89 | 1.88 | Replacement of Starting/Running Capacitor without supply for 1T Window/Split type AC. | item92 | 5 | Nos |
90 | 1.89 | Replacement of Starting/Running Capacitor with supply for 1.5 T Window/Split type AC. | item93 | 30 | Nos |
91 | 1.9 | Replacement of Starting/Running Capacitor without supply for 1.5 T Window/Split type AC. | item94 | 10 | Nos |
92 | 1.91 | Replacement of Starting/Running Capacitor with supply for 2 T Window/Split type AC. | item95 | 30 | Nos |
93 | 1.92 | Replacement of Starting/Running Capacitor without supply for 2 T Window/Split type AC. | item96 | 10 | Nos |
94 | 1.93 | Replacement of Strainer Capillary with supply for 1 T / 1.5 T / 2T / 3 T Split/Window Type AC machine. | item97 | 2 | Nos |
95 | 1.94 | Connection with supply of Drain pipe per meter for Split/Window/Standing type AC m/c of capacity 1 T /1.5 T /2 T /3 T. | item98 | 200 | Nos |
96 | 1.95 | AC machine Split / Window compressor repairing capacity 1 T. | item99 | 1 | No |
97 | 1.96 | AC machine Split / Window compressor repairing capacity 1.5 T / 2 T. | item100 | 4 | Nos |
98 | 1.97 | AC machine Split compressor repairing capacity 3 T. | item101 | 1 | No |
99 | 1.98 | AC machine Ductable compressor repairing capacity 3 T. | item102 | 1 | No |
100 | 1.99 | AC machine standing A.C compressor repairing capacity 3T. | item103 | 1 | No |
101 | 2 | AC machine standing A.C compressor repairing capacity 4T. | item104 | 1 | No |
102 | 2.01 | Partial Gas top up /partial gas filling of 1T/1.5T/2.0/2.5/3T/4T Capacity AC m/c including supply of gas. | item105 | 70 | Nos |
103 | 2.02 | Supply & Filling of gas (Full gas charging)R-22/ R- 410a for Window Type AC machine Capacity 1 T. | item106 | 6 | Nos |
104 | 2.03 | Supply & Filling of gas (Full gas charging)R-22/ R- 410a for Window Type AC machine Capacity 1.5 T. | item107 | 12 | Nos |
105 | 2.04 | Supply & Filling of gas (Full gas charging)R-22/ R- 410a for Window Type AC machine Capacity 2 T. | item108 | 6 | Nos |
106 | 2.05 | Supply & Filling of gas (Full gas charging)R-22/ R- 410a for Split Type AC machine Capacity 1 T. | item109 | 6 | Nos |
107 | 2.06 | Supply & Filling of gas(Full gas charging) R-22/ R- 410a for Split Type AC machine Capacity 1.5 T | item110 | 48 | Nos |
108 | 2.07 | Supply & Filling of gas (Full gas charging)R-22/ R- 410a for Split Type AC machine Capacity 2 T | item111 | 24 | Nos |
109 | 2.08 | Supply & Filling of gas(Full gas charging) R-22/ R- 410a for Standing Type AC machine Capacity 4T | item112 | 6 | Nos |
110 | 2.09 | Supply & Filling of gas (Full gas charging)R-22/ R- 410a for Split Type AC machine Capacity 3 T | item113 | 2 | Nos |
111 | 2.1 | Supply & Filling of gas(Full gas charging) R-22/ R- 410a for Ductable Type AC machine Capacity 3 T | item114 | 2 | Nos |
112 | 2.11 | Supply & Filling of gas(Full gas charging) R-22/ R- 410a for Standing Type AC machine Capacity 2 T | item115 | 2 | Nos |
113 | 2.12 | Supply & Filling of gas R-22/ R- 410a for Ductable Type AC machine Capacity 7.5T | item116 | 1 | No |
114 | 2.13 | Repairing/Rewinding of Blower Motor/Cooling Motor for Split/Window/Standing type AC Machine of capacity 1 T /1.5 T /2 T /3 T. | item117 | 2 | Nos |
115 | 2.14 | Repairing/Rewinding of Cooling Motor (3 phase, 3 HP) for Ductabler type AC Machine of capacity 7.5 T. | item118 | 1 | No |
116 | 2.15 | Repairing/Rewinding of Condensor Motor (Single phase, 0.5 HP) for Ductable type AC Machine of capacity 7.5 T. | item119 | 1 | No |
117 | 2.16 | Overhauling of Window. machine which includes Servicing and cleaning of Window A.C . Servicing includes cleaning of filter pads and condenser /evaporator coils by c shine alkane coil cleaner or other cleaner materials. Capacity 1 T. | item120 | 12 | Nos |
118 | 2.17 | Overhauling of Window machine which includes Servicing and cleaning of Window A.C . Servicing includes cleaning of filter pads and condenser /evaporator coils by c shine alkane coil cleaner or other cleaner materials. Capacity 1.5 T. | item121 | 50 | Nos |
119 | 2.18 | Overhauling of Window machine which includes Servicing and cleaning of Window A.C . Servicing includes cleaning of filter pads and condenser /evaporator coils by c shine alkane coil cleaner or other cleaner materials.Capacity 2 T | item122 | 50 | Nos |
120 | 2.19 | Overhauling of Split AC machine which includes Servicing and cleaning of Spit AC indoor/outdoor unit . Servicing includes cleaning of filter pads and condenser /evaporator coils by c shine alkane coil cleaner or other cleaner materials Capacity 1.5 T | item123 | 200 | Nos |
121 | 2.2 | Overhauling of Split AC machine which includes Servicing and cleaning of Spit AC indoor/outdoor unit . Servicing includes cleaning of filter pads and condenser /evaporator coils by c shine alkane coil cleaner or other cleaner materials Capacity 2 T | item124 | 200 | Nos |
122 | 2.21 | Overhauling of Standing A.C. machine Capacity 3 T | item125 | 10 | Nos |
123 | 2.22 | Overhauling of Standing A.C. machine Capacity 2 T/2.5T | item126 | 8 | Nos |
124 | 2.23 | Overhauling of Standing A.C. machine Capacity 4 T | item127 | 4 | Nos |
125 | 2.24 | Filter pad replacement of 1 T / 1.5 T/2T Split/Window type AC Machine with supply | item128 | 4 | Nos |
126 | 2.25 | Filter pad replacement of 2 T / 3 T Split/Window/Standing/Ductable type AC Machine with supply | item129 | 4 | Nos |
127 | 2.26 | Filter pad replacement of 7.5 T Ductable type AC Machine with supply | item130 | 1 | No |
128 | 2.27 | Fan Blade replacement for Split / Window AC M/c of capacity 1T /1.5T /2 T/4T. | item131 | 5 | Nos |
129 | 2.28 | Fan Blade replacement for Split AC Machine of capacity 3 T | item132 | 1 | Nos |
130 | 2.29 | Fan Blade replacement for Standing AC Machine of capacity 3T | item133 | 1 | No |
131 | 2.3 | Fan Blade replacement for Ductable type AC Machine of capacity 7.5 T | item134 | 1 | No |
132 | 2.31 | Air filter checking and cleaning for Split / Window AC M/c of capacity 1 T /1.5 T /2 T /3 T/4T. | item135 | 30 | Nos |
133 | 2.32 | Condenser coil, cooling coil cleaning& tit-bit jobs as required including cleaning of area of A.C machines | item136 | 20 | Nos |
134 | 2.33 | Electrical connection checking & rectification of minor Tit-Bit jobs regarding electric supply line. | item137 | 20 | Nos |
135 | 2.34 | Replacement of Front Grille for 1 T /1.5 T /2 T window type AC m/c | item138 | 2 | Nos |
136 | 2.35 | Replacement of Flapper for 1 T /1.5 T /2 T window/split type AC m/c | item139 | 2 | Nos |
137 | 2.36 | Replacement of Flapper motor/air swing motor for 1 T /1.5 T /2 T window/split type AC m/c | item140 | 1 | No |
138 | 2.37 | V-Belt Replacement For 7.5 T capacity Ductable type A.C. | item141 | 1 | No |
139 | 2.38 | Total Duct Cleaning For 7.5 TR capacity Ductable type A.C. | item142 | 1 | No |
140 | 2.39 | Per point Identification of gas leakage & rectification in Split / Window AC/Ductable/standing A.C of capacity 1 T /1.5 T /2 T /3 T/4T .( Leakage is subject to realisation by testing) | item143 | 50 | Nos |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail