Provision Of Open Shed For Armoured Vehicle , Provn Of Stone Pitched Paving For A Vehicle And Provn Of Air Circulator Fan Under Age Br-Iii And Age Em-V Office Of Ge North Bathinda At Bathinda Mil Stn, Bathinda Mil Stn-Punjab

Military Engineer Services-MES has published Provision Of Open Shed For Armoured Vehicle , Provn Of Stone Pitched Paving For A Vehicle And Provn Of Air Circulator Fan Under Age Br-Iii And Age Em-V Office Of Ge North Bathinda At Bathinda Mil Stn. Submission Date for this Tender is 02-03-2021. Air Circulators Tenders in Bathinda Mil Stn Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

26897147
Corrigendum : Provision Of Open Shed For Armoured Vehicle , Provn Of Stone Pitched Paving For A Vehicle And Provn Of Air Circulator Fan Under Age Br-Iii And Age Em-V Office Of Ge North Bathinda At Bathinda Mil Stn
National Competitive Bid
Indian
Punjab
Bathinda Mil Stn
02-03-2021

Tender Details

Provision Of Open Shed For Armoured Vehicle , Provn Of Stone Pitched Paving For A Vehicle And Provn Of Air Circulator Fan Under Age Br-Iii And Age Em-V Office Of Ge North Bathinda At Bathinda Mil Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Feb-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-03-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
INR 20 Lakhs /-

BOQ Items

Name of Work : PROVN OF OPEN SHED FOR ARMOURED VEHICLE, PROVN OF STONE PITCHED PAVING FOR A VEHICLE AND PROVN OF AIR CIRCULATOR FAN UNDER AGE BR-III AND AGE EM-V OFFICE OF GE NORTH BATHINDA AT BATHINDA MIL STN
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in post holes in soft/loose soil n. exc 0.50 cum each, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25 cm including removing of surplus spoil to a distance n exc 50 mtr and making good the disturbed surfaces all as specified and directed by Engineer-in-Charge. 18 Each
2 2 Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil including cutting of grass, roots, bushes if any and filling of lower portion with soil obtained from cutting and dressing complete all as specified and as directed by Engineer-in-charge. 825 Sqm
3 3 Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cess pits, manholes, for taking out old pipe and laying new pipe line, for laying cable etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge. 20.5 Cum
4 4 Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge. 8.24 Cum
5 5 Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge. 12.26 Cum
6 6 Material and labour for 150mm thick (spread thickness) soling (or sub base) with broken boulders or quarried stone, interstices filled, watered and rolled with 8 to 12 tonne power roller, filling in hollows and depressions which occurs during the process of rolling and made up to form true surface and consolidated to required gradient and camber etc complete all as specified and directed by Engineer-in-Charge. 82.5 X Sqm
7 7 Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. 160 Sqm
8 8 Material and labour for 100mm thick cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and as directed by Engineer-in-charge. 665 Sqm
9 9 Material and labour for PCC ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge. 6.5 Cum
10 10 Material and labour for PCC (1:2:4), type B-1 using 20 mm graded stone aggregate as in foundation filling and mass concrete, bed block, for embedded posts & similar work etc complete all as specified and as directed by Engineer-in-charge. 2.25 Cum
11 11 Material and labour for Stone sett flooring (stone sett road) with stone setts of size 200 to 250mm long, 150 to 200mm wide and 150mm deep and sides dressed bedded in cement mortar (1:3), 20mm thick joints grouted in cement mortar (1:2) with an admixture of metallic floor hardner (Iron) 5% by weight of cement and struck flush complete all as speccified and as direccted by Engineer-in-charge. NOTE : (i) Matellic hardner shall be measured and paid separately under appropriate item of BOQ as supply only. 665 Sqm
12 12 Supply only matellic hardner complete all as specified and as directed by the Engineer-in-Charge. 135 Kg
13 13 Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.\n 5 Cum
14 14 Material and labour for rendering/plastering 15mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. 100 Sqm
15 15 Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge. 527 Sqm
16 16 Supply and fixing Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick including ridge of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge. 18.6 Sqm
17 17 Material and labour for mild steel framed work, framed/truss work for fixing GI sheets (design for framing as directed by Engineer-in-charge) and using hollow square/rectangular pipe, or other section like angle, tee, plate, distance pieces, cleats etc. and cut to shape, drilled and counter sunk for screw, as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and fixed with angle cleats or other connecting plates, gusset plates, brackets, bending and welding, riveting etc, conforming to Gde Fe-410-W (Gde E-250 quality A) complete all as specified and as directed by the Engineer-in-Charge. 2484 Kg
18 18 Material and labour for mild steel work tubular poles/post including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to latest relevant IS grade St-240 complete all as specified & directed by Engineer-in- charge. 1806 Kg
19 19 Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down or by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified and as directed by Engineer-in-Charge. 100 Sqm
20 20 Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in- charge. 200 Sqm
21 21 Material and labour for concealed Point wiring complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC rigid conduit 20mm dia (heavy duty) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and 1.2mm thick) concealed in wall, 3mm thick bakelite plastic laminated hylem sheet for mounting of switches/socket/regulator with brass screws & cup washers and covering with and including frame, wiring for light /fan/ bell point controlled by one switch (on indipendent board), including provn of 1.5 Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ). 46 Per Point
22 22 All as per above Srl item No. 21 but for one socket out let 5/6 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge. (switches, sockets etc. shall be measured and paid separately under appropriate item of BOQ). 2 Per Point
23 23 All as per above Srl item No. 21 but for one socket out let 5/6 Amps point controlled by one switch (on indipendent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ). 4 Per Point
24 24 Material and labour for concealed Point wiring complete with 2.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC rigid conduit 20mm dia (heavy duty) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and 1.2mm thick), 3mm thick bakelite plastic laminated hylem sheet for mounting of switches/socket with brass screws & cup washers and covering with and including frame, wiring for one socket out let 15/16 Amps point controlled by one switch (on indipendent board), including provn of 2.5 Sqmm FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ). 4 Per Point
25 25 Supply and fixing switch piano flush type (ISI marked) semi modular, 5/6Amps, single pole, one way fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet and covering frame shall be measured and paid in point wiring item of BOQ). 52 Each
26 26 Supply and fixing Socket outlet multipurpose type (ISI marked) semi modular, 2 in 1, 3/5 pin 5/6 Amp, flush type fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet and covering frame shall be measured and paid in point wiring item of BOQ). 6 Each
27 27 Supply and fixing switch piano flush type (ISI marked) semi modular, 15/16Amps, single pole, one way complete all as specified and as directed by Engineer-in-charge. (laminated sheet and covering frame shall be measured and paid in point wiring item of BOQ). 4 Each
28 28 Supply and fixing Socket outlet multipurpose type (ISI marked) semi modular, 2 in 1, 3/5 pin 15/16 Amp, flush type fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet and covering frame shall be measured and paid in point wiring item of BOQ). 4 Each
29 29 Supply and fixing ceiling rose (ISI marked) surface type polycarbonate isolated body two to three terminal, topline series 20x50mm, 6 Amp, 250 volts, complete all as specified and as directed by Engineer-in-Charge. 46 Each
30 30 Material and labour for concealed sub main wiring with 2.5 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 2.5 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge.\nNote :-Three run of 2.5 sqmm copper wire and one run conduit shall be measured as one RM length for payment. 40 RM
31 31 Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 12 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.\nNote :- MCB’s shall be measured and paid separately under appropriate item of BOQ. 1 Each
32 32 Supply and fixing MCB ‘C’ curve suitable for 240 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge. 10 Each
33 33 Supply and fixing isolator ‘C’ curve suitable for 230 volts AC supply, 63 Amps, SPN and rupturing capacity not less than 10 KA, complete all as specified and as directed by Engineer-in-charge. 1 Each
34 34 Supply and fixing wall mounted LED Batten T-8 Retro LED 18/20 watt (100 lumens per watt), appx 4 feet long, pre wired including LED tube light with in built driver, not less than 6000K, complete fitting and all other accessories fitting arrangements including electric connection complete all as specified and as directed by Engineer-in-Charge. \nMake - Cat part No BLRB 18W CWc and BLRB-DB 118 of Bajaj / LT8-20-865-2 and DMLN1LT8-16 of Crompton / PHOTONULTRA 1213T8SSTL 18W LED865SPC and REGALBATTENT 8UPTO1X22 WSSBSWH of Havells 12 Each
35 35 Supply and fixing Sleek Pressure die cast aluminium housing/body, heat resistant clear glass, LED lens for wide beam, energy saving, IP65/66 protection, not less than 5700K, better optics for uniform distribution street/Roadway luminaire with high power LED 25 watt complete fitting with driver, LED strip and all other accessories etc, suitable for 40/32mm OD entry for direct mounting on pipe bracket, fixing on poles/along wall with and including brackets made out of GI tubing light grade 40mm dia, 2 metre long bent to shape at 120 degree angle at half metre from bottom (as per sample), fixing with MS clamp (02 Nos) and nut bolts, including before fixing applying two coats of aluminium paint on bracket and clamp over a coat of red oxide primer, including making electric connection with using twin core copper cable of suitable size complete all as specified and as directed by Engineer-in-charge.\nMake - Cat part No LSTS-25-CDL of Crompton/ BRLEP 25W LED WH of Bajaj / ENDURA PEARL SL25W LED757SASYTOPC of Havells 2 Each
36 36 Supply and fixing energy saving IP65 flood light luminaire, high pressure die cast LED light fitting (100 lumens per watt) not less than 5700K, complete fitting with LED strips and all other accessories and fitting arrangements including connecting electric connection, complete all as specified and directed by Engineer-in-Charge. Note : Light Fitting fixing at any height of shed on roof/along pole /along wall and cost for arrangement shall be included in the unit rate nothing shall be paid extra on this account.\nMake : Cat part No. LFL-60-CDL/60 of Crompton / BJFL 60W LED I of Bajaj / PCGLF T102 6057 of Polycab /JETA COMPECT OFL50WLED 757LTG of Havells 8 Each
37 37 Supply and laying XLPE LT Cable of size 25 Sqmm, 2 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-charge. \nNote :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.) 60 RM
38 38 Supply and filling Local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and as directed by Engineer-in-Charge. (Note :- For measurement purpose puned thickness shall be measured and paid i.e 18cm.) 4.05 Cum
39 39 Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge. 0.43 Per 1000 Nos
40 40 Supply and fixing/laying GI tubing, light grade, 40 mm bore for protection of cable or earthing lead wire under hardstanding/fixed along poles/wall, laid in in trenches etc complete all as specified and as directed by Engineer-in-Charge. 8 RM
41 41 Supply and fixing Air Circulator Wall Mounted Fan 600 mm sweep single phase, 230 volts 50 Hz double ball bearing energy efficiant, three curvy metal blades / Aerodynamically designed blades with fine finishing, Rigid frame for protection from foreign matters /Sturdy close-mesh guards and Highly powerful motor for high air thrust including fixing material including electrical connection complete all as specified and directed by Engineer-in-Charge\nMake - AC600WALL 1 of Crompton / Supreme Plus 600mm of Bajaj / Dominaire 600 mm Industrial of USHA / FHACWSTSCL24 600 mm Turboforce of Havells 8 Each
42 42 Supply and fixing Air Circulator Wall Mounted Fan 450 mm sweep single phase, 230 volts 50 Hz double ball bearing energy efficiant, three curvy metal blades / Aerodynamically designed blades with fine finishing, Rigid frame for protection from foreign matters /Sturdy close-mesh guards and Highly powerful motor for high air thrust including fixing material including electrical connection complete all as specified and directed by Engineer-in-Charge\nMake - AC450WALL 1 of Crompton / Supreme Plus 450mm of Bajaj / Dominaire 450 mm Industrial of USHA / FHACWSTSCL18 450 mm Turboforce of Havells 16 Each
43 43 Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos- 8mm dia 25mm long hex head screw. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover 10mm thick hanged to CFI frame, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate), including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and and as directed by Engineer-in-charge.\nNote:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. 2 Each Job