Installation Of Jci 03 Ac Compressors- In Ship, NAVAL DOCKYARD VISAKHAPATNAM-Andhra Pradesh

Indian Navy-IN has published Installation Of Jci 03 Ac Compressors- In Ship. Submission Date for this Tender is 18-02-2021. Pressure Switches Tenders in NAVAL DOCKYARD VISAKHAPATNAM Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

26883461
Installation Of Jci 03 Ac Compressors- In Ship
Open Tender
Indian
Andhra Pradesh
NAVAL DOCKYARD VISAKHAPATNAM
18-02-2021

Tender Details

Installation Of Jci 03 Ac Compressors- In Ship , Installation And Commissioning Of Jci Make Ac Compressorsjoint Inspection Of Plant Supplied By Mo ( V ) , Installation And Commissioning Of Jci Make Ac Compressorssupply Of New Foundation Drawing For Manufacturing , Installation And Commissioning Of Jci Make Ac Compressorsshifting And Installation Of New Foundation Onboard Ship , Installation And Commissioning Of Jci Make Ac Compressorsfitment Of Shock Mounts , Installation And Commissioning Of Jci Make Ac Compressorsshifting Of Ac Plants To Foundation , Installation And Commissioning Of Jci Make Ac Compressorsconnecterisation Of Plants To Electrical Supply , Installation And Commissioning Of Jci Make Ac Compressorsprovisioning Of Necessary Sockets On Sea Water And Chilled Water Pipe Lines , Installation And Commissioning Of Jci Make Ac Compressorspt , Vt , Oil Charging And Gas Charging , Installation And Commissioning Of Jci Make Ac Compressorsstw & Mtu Trials , Installation And Commissioning Of Jci Make Ac Compressorssubmit Operating And Manufacturing Manual For Reference , Installation And Commissioning Of Jci Make Ac Compressorstraining For Operations , Mandatory Spare:- . Suction Line Piping With Necessary Valves And Fittings . , Mandatory Spare:- . Discharge Line Piping With Necessary Valves And Fittings . , Mandatory Spare:- . Liquid Injection Line With Necessary Valves And Fittings . , Mandatory Spare:- . Vibration Eliminator For Suction Line . , Mandatory Spare:- . Vibration Eliminator For Discharge Line . , Mandatory Spare:- . Base Frame . , Mandatory Spare:- . Refrigerant R134a . , Mandatory Spare:- . Poe Oil . , Mandatory Spare:- . Press Switch , 1/4 Npt ( M ) , Suction Pressure . , Mandatory Spare:- . Press Switch , 1/4 Npt ( M ) , Discharge Pressure . , Mandatory Spare:- . Oil Pressure Switch , 1/4 Npt ( M ) . , Mandatory Spare:- . Temperature Switch , Suction Temperature . , Mandatory Spare:- . Temperature Switch , Discharge Temperature . , Mandatory Spare:- . Press Trans 1/4 Npt ( M ) , Suction Pressure . , Mandatory Spare:- . Press Trans 1/4 Npt ( M ) , Discharge Pressure . , Mandatory Spare:- . Temperature Probe , ( -50 ) To 100 Degc , Suction , Dicharge , Chilled Water . , Mandatory Spare:- . Pg Bourden Type 0 To 25 Kg/Cm2 ( G ) , 1/4 Npt ( M ) . , Mandatory Spare:- . Dpg For Oil 0 To 10 Kg/Cm2 ( G ) , 1/4Npt ( M ) . , Mandatory Spare:- . Pg Bourden Type 0 To 10 Kg/Cm2 ( G ) , 1/4 Npt ( M ) . , Mandatory Spare:- . Pg Glycerine ( - ) 1 To 9 Kg/Cm2 ( G ) , 1/4 Npt ( M ) . , Mandatory Spare:- . Temperature Guage ( Machine Glass ) ( - ) 30 To 50 Degc . , Mandatory Spare:- . Temperature Guage ( Machine Glass ) 0 To 100 Degc . , Mandatory Spare:- . Liquid Injection Solenoid Valve . , Mandatory Spare:- . Liquid Injection Tcv . , Mandatory Spare:- . Flow Switch - Chilled Water And Sea Water . , Mandatory Spare:- . Thermostatic Expansion Valve . , Mandatory Spare:- . Solenoid Valve With Strainer . , Mandatory Spare:- . Filter Drier Core . , Mandatory Spare:- . Filter Drier Housing .

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: <Installation of JCI 03 AC compressors IN SHIP >
Sl.No (A) Item Description (B) Item Code / Make Quantity (C) Units (D)
1 1.01 Installation and commissioning of JCI make AC compressorsJoint inspection of plant supplied by MO(V) Item no 1 3 Nos
2 1.02 Installation and commissioning of JCI make AC compressorsSupply of new foundation drawing for manufacturing Item no 2 3 Nos
3 1.03 Installation and commissioning of JCI make AC compressorsShifting and installation of new foundation onboard ship Item no 3 3 Nos
4 1.04 Installation and commissioning of JCI make AC compressorsFitment of shock mounts Item no 4 3 Nos
5 1.05 Installation and commissioning of JCI make AC compressorsShifting of AC plants to foundation Item no 5 3 Nos
6 1.06 Installation and commissioning of JCI make AC compressorsConnecterisation of plants to electrical supply Item no 6 3 Nos
7 1.07 Installation and commissioning of JCI make AC compressorsProvisioning of necessary sockets on sea water and chilled water pipe lines Item no 7 3 Nos
8 1.08 Installation and commissioning of JCI make AC compressorsPT, VT, oil charging and gas charging Item no 8 3 Nos
9 1.09 Installation and commissioning of JCI make AC compressorsSTW & MTU trials Item no 9 3 Nos
10 1.1 Installation and commissioning of JCI make AC compressorsSubmit operating and manufacturing manual for reference Item no 10 3 Nos
11 1.11 Installation and commissioning of JCI make AC compressorsTraining for operations Item no 11 3 Nos
12 2.01 Mandatory spare:-.Suction line piping with necessary valves and fittings. Item no 12 3 Nos
13 2.02 Mandatory spare:-.Discharge line piping with necessary valves and fittings. Item no 13 3 Nos
14 2.03 Mandatory spare:-.Liquid injection line with necessary valves and fittings. Item no 14 3 Nos
15 2.04 Mandatory spare:-.Vibration eliminator for suction line. Item no 15 3 Nos
16 2.05 Mandatory spare:-.Vibration eliminator for discharge line. Item no 16 3 Nos
17 2.06 Mandatory spare:-.Base frame. Item no 17 3 Nos
18 2.07 Mandatory spare:-.Refrigerant R134A. Item no 18 540 kg
19 2.08 Mandatory spare:-.POE oil. Item no 19 60 Litres
20 2.09 Mandatory spare:-.Press switch, 1/4" NPT(M), Suction pressure. Item no 20 3 Pcs
21 2.1 Mandatory spare:-.Press switch, 1/4" NPT(M), Discharge pressure. Item no 21 3 Pcs
22 2.11 Mandatory spare:-.Oil pressure switch, 1/4" NPT(M). Item no 22 3 Pcs
23 2.12 Mandatory spare:-.Temperature switch, Suction temperature. Item no 23 6 Pcs
24 2.13 Mandatory spare:-.Temperature switch, Discharge temperature. Item no 24 6 Pcs
25 2.14 Mandatory spare:-.Press trans 1/4" NPT(M), Suction pressure. Item no 25 3 Pcs
26 2.15 Mandatory spare:-.Press trans 1/4" NPT(M), Discharge pressure. Item no 26 12 Pcs
27 2.16 Mandatory spare:-.Temperature probe, (-50) to 100 Degc, suction, dicharge, chilled water. Item no 27 12 Pcs
28 2.17 Mandatory spare:-.PG bourden type 0 to 25 kg/cm2 (G), 1/4" NPT (M). Item no 28 6 pcs
29 2.18 Mandatory spare:-.DPG for oil 0 to 10 kg/cm2 (G), 1/4"NPT(M). Item no 29 3 pcs
30 2.19 Mandatory spare:-.PG bourden type 0 to 10 kg/cm2 (G), 1/4" NPT (M). Item no 30 12 Pcs
31 2.2 Mandatory spare:-.PG Glycerine(-) 1 to 9 kg/cm2 (G), 1/4" NPT (M). Item no 31 3 pcs
32 2.21 Mandatory spare:-.Temperature guage (machine glass) (-) 30 to 50 degc. Item no 32 9 Pcs
33 2.22 Mandatory spare:-.Temperature guage (machine glass) 0 to 100 degc. Item no 33 6 Pcs
34 2.23 Mandatory spare:-.Liquid injection solenoid valve. Item no 34 6 Pcs
35 2.24 Mandatory spare:-.Liquid injection TCV. Item no 35 3 Pcs
36 2.25 Mandatory spare:-.Flow switch - chilled water and sea water. Item no 36 6 Pcs
37 2.26 Mandatory spare:-.Thermostatic Expansion Valve. Item no 37 6 Pcs
38 2.27 Mandatory spare:-.Solenoid valve with strainer. Item no 38 6 Pcs
39 2.28 Mandatory spare:-.Filter drier core. Item no 39 12 Pcs
40 2.29 Mandatory spare:-.Filter drier housing. Item no 40 3 Pcs
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail