Indian Navy-IN has published Installation Of Jci 03 Ac Compressors- In Ship. Submission Date for this Tender is 18-02-2021. Pressure Switches Tenders in NAVAL DOCKYARD VISAKHAPATNAM Andhra Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: <Installation of JCI 03 AC compressors IN SHIP > | |||||
---|---|---|---|---|---|
Sl.No (A) | Item Description (B) | Item Code / Make | Quantity (C) | Units (D) | |
1 | 1.01 | Installation and commissioning of JCI make AC compressorsJoint inspection of plant supplied by MO(V) | Item no 1 | 3 | Nos |
2 | 1.02 | Installation and commissioning of JCI make AC compressorsSupply of new foundation drawing for manufacturing | Item no 2 | 3 | Nos |
3 | 1.03 | Installation and commissioning of JCI make AC compressorsShifting and installation of new foundation onboard ship | Item no 3 | 3 | Nos |
4 | 1.04 | Installation and commissioning of JCI make AC compressorsFitment of shock mounts | Item no 4 | 3 | Nos |
5 | 1.05 | Installation and commissioning of JCI make AC compressorsShifting of AC plants to foundation | Item no 5 | 3 | Nos |
6 | 1.06 | Installation and commissioning of JCI make AC compressorsConnecterisation of plants to electrical supply | Item no 6 | 3 | Nos |
7 | 1.07 | Installation and commissioning of JCI make AC compressorsProvisioning of necessary sockets on sea water and chilled water pipe lines | Item no 7 | 3 | Nos |
8 | 1.08 | Installation and commissioning of JCI make AC compressorsPT, VT, oil charging and gas charging | Item no 8 | 3 | Nos |
9 | 1.09 | Installation and commissioning of JCI make AC compressorsSTW & MTU trials | Item no 9 | 3 | Nos |
10 | 1.1 | Installation and commissioning of JCI make AC compressorsSubmit operating and manufacturing manual for reference | Item no 10 | 3 | Nos |
11 | 1.11 | Installation and commissioning of JCI make AC compressorsTraining for operations | Item no 11 | 3 | Nos |
12 | 2.01 | Mandatory spare:-.Suction line piping with necessary valves and fittings. | Item no 12 | 3 | Nos |
13 | 2.02 | Mandatory spare:-.Discharge line piping with necessary valves and fittings. | Item no 13 | 3 | Nos |
14 | 2.03 | Mandatory spare:-.Liquid injection line with necessary valves and fittings. | Item no 14 | 3 | Nos |
15 | 2.04 | Mandatory spare:-.Vibration eliminator for suction line. | Item no 15 | 3 | Nos |
16 | 2.05 | Mandatory spare:-.Vibration eliminator for discharge line. | Item no 16 | 3 | Nos |
17 | 2.06 | Mandatory spare:-.Base frame. | Item no 17 | 3 | Nos |
18 | 2.07 | Mandatory spare:-.Refrigerant R134A. | Item no 18 | 540 | kg |
19 | 2.08 | Mandatory spare:-.POE oil. | Item no 19 | 60 | Litres |
20 | 2.09 | Mandatory spare:-.Press switch, 1/4" NPT(M), Suction pressure. | Item no 20 | 3 | Pcs |
21 | 2.1 | Mandatory spare:-.Press switch, 1/4" NPT(M), Discharge pressure. | Item no 21 | 3 | Pcs |
22 | 2.11 | Mandatory spare:-.Oil pressure switch, 1/4" NPT(M). | Item no 22 | 3 | Pcs |
23 | 2.12 | Mandatory spare:-.Temperature switch, Suction temperature. | Item no 23 | 6 | Pcs |
24 | 2.13 | Mandatory spare:-.Temperature switch, Discharge temperature. | Item no 24 | 6 | Pcs |
25 | 2.14 | Mandatory spare:-.Press trans 1/4" NPT(M), Suction pressure. | Item no 25 | 3 | Pcs |
26 | 2.15 | Mandatory spare:-.Press trans 1/4" NPT(M), Discharge pressure. | Item no 26 | 12 | Pcs |
27 | 2.16 | Mandatory spare:-.Temperature probe, (-50) to 100 Degc, suction, dicharge, chilled water. | Item no 27 | 12 | Pcs |
28 | 2.17 | Mandatory spare:-.PG bourden type 0 to 25 kg/cm2 (G), 1/4" NPT (M). | Item no 28 | 6 | pcs |
29 | 2.18 | Mandatory spare:-.DPG for oil 0 to 10 kg/cm2 (G), 1/4"NPT(M). | Item no 29 | 3 | pcs |
30 | 2.19 | Mandatory spare:-.PG bourden type 0 to 10 kg/cm2 (G), 1/4" NPT (M). | Item no 30 | 12 | Pcs |
31 | 2.2 | Mandatory spare:-.PG Glycerine(-) 1 to 9 kg/cm2 (G), 1/4" NPT (M). | Item no 31 | 3 | pcs |
32 | 2.21 | Mandatory spare:-.Temperature guage (machine glass) (-) 30 to 50 degc. | Item no 32 | 9 | Pcs |
33 | 2.22 | Mandatory spare:-.Temperature guage (machine glass) 0 to 100 degc. | Item no 33 | 6 | Pcs |
34 | 2.23 | Mandatory spare:-.Liquid injection solenoid valve. | Item no 34 | 6 | Pcs |
35 | 2.24 | Mandatory spare:-.Liquid injection TCV. | Item no 35 | 3 | Pcs |
36 | 2.25 | Mandatory spare:-.Flow switch - chilled water and sea water. | Item no 36 | 6 | Pcs |
37 | 2.26 | Mandatory spare:-.Thermostatic Expansion Valve. | Item no 37 | 6 | Pcs |
38 | 2.27 | Mandatory spare:-.Solenoid valve with strainer. | Item no 38 | 6 | Pcs |
39 | 2.28 | Mandatory spare:-.Filter drier core. | Item no 39 | 12 | Pcs |
40 | 2.29 | Mandatory spare:-.Filter drier housing. | Item no 40 | 3 | Pcs |