Supply Of Digital Electronic Balance , Uv-Vis Spectrophotometer , Digital Turbidity Meter , Hot Air Oven , Auto Burette , Digital Micropipette , Autoclave Etc . Complete In All Respect .
Tender Value
9.95 Lakhs
Estimated cost
Bid Submission
15 Feb 2021
0 days left
EMD
19900
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
District Laboratory, Rewari → Haryana
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Supply Of Digital Electronic Balance , Uv-Vis Spectrophotometer , Digital Turbidity Meter , Hot Air Oven , Auto Burette , Digital Micropipette , Autoclave Etc . Complete In All Respect .
BOQ
| Name of Work: Supply of Digital Electronic Balance, UV-VIS Spectrophotometer, Digital Turbidity Meter, Hot Air Oven, Auto Burette, Digital Micropipette, Autoclave etc. complete in all respect. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Digital Electronic Balance Make Make: Ohaus/Shimazo/ Mettler Toledo Capacity 220gm., Readability 0.1mg, Pan Size(mm) : 85-91 mm dia High Contrast, Large Backlite LCD display for easy viewing with A.E.P. (Advanced Eye Protection) Standard RS 232 C interface. Automatic Internal calibration Various weighing units like gm, mg, ct, oz, dwt, mom, GN User selectable stability and filter level. \n Calibration: Calibration certificate from any NABL certified Laboratory required with validity of at least 1 Year. \n | 1 | No. | |
| 2 | 2 | Digital Turbidity Meter: Hach Specifications • Turbidity Range 0 to 1000 NTU • Resolution & Accuracy 0.01 NTU (0 to 9.99 NTU); 0.1 NTU (10 to 99.9 NTU); 1 NTU (100 to 1000 NTU) & ± 2% of measured range + 0.01 NTU • No. of Calibration Points Up to 3 points • Calibration Options 4 points (0.02, 10, 100, 1000) • Light Source White light (tungsten) • Response Time < 6 seconds • Power 12 VDC, using AC adapters 110 VAC or 220 VAC, 50/60 Hz\n | 1 | No. | |
| 3 | 3 | HOT AIR OVEN -Make Iso certified Company (Specifications)\n• Inner Chamber SIZE:18”X18”X18”inch(LxWxD)\n• Double walled inner chamber available in stainless steel with grade304. \n• Outer chamber made of Stainless Steeel\n• Glass wool/ PUF insulation to prevent temperature loss. \n• Outer double wall door is provided with gas kit.\n• Stainless steel removable & adjustable shelves .\n• No. of Shelves-3nos\n• Digital display with mains ON/OFF, switch indicating lamps & Fuse \n• Digital microprocessor based PID Temp controller with LED Display \n• accuracy of temperature +/- 0.5 degree\n• Temperature range adjustable from Room Temp. to2600C (resolution 0.10C)\n• Air flow systems providing Blower for even distribution of temperature.tt\n• Safety thermostat to prevent over heat. \n• Electric Supply:220/230V AC,50/60 Hz,2500watt\nCalibration Certifiate From NABL Certified Lab Required\n | 1 | No. | |
| 4 | 4 | Digital Micro Pipette\nVariable Volume 0.05 ml to 5 ml\nMake : Mettler Toledo/ Borosil | 2 | No. | |
| 5 | 5 | Digital Micro Pipette\nVariable Volume 10 ml to 20 ml\nMake : Mettler Toledo/ Borosil\n | 2 | No. | |
| 6 | 6 | Spectrophotometer - Pre-programmed Water AnalyzerMake - HACH (DR 6000) With 1 No. Hachpack (Nitrate,Iron,Sulphate,Flouride)\n1. Operating Mode= Transmittance (%), absorbance and concentration (wavelength, time) 2. Source Lamp= Tungsten (visible range), deuterium\n3. Display= TFT 7 inch WVGA color touch 4. Data Logger= 5000 data points (result, date, time, sample-ID, user-ID) (UV range) 5. Wavelength Range= 190 - 1100 nm 6. Preprogrammed Methods= > 250\n7. Wavelength A+C79ccuracy= ± 1 nm User Programs 200\n8. Wavelength Reproducibility= < 0.1 nm nm 9. Sample Cell Compatibility= Rectangular: 10, 20, 30, 50 mm, 1 inch; round: 13 mm, 16 mm, 1 inch 10. Wavelength Resolution= 0.1 nm 11. Wavelength Selection= Automatic, based on method selection 12. Spectral Bandwidth= 2 nm 13. Dimensions (H x W x D)= Optional 100 mm rectangular cell with additional adapter 8.5 in x 19.7 in x 18.1 in (215 mm x 500 mm x 460 mm) 14. Scanning Speed= 900 nm/min (in 1 nm steps)\n15. Weight= 24.25 lbs. (11 kg) 16. Photometric Measuring Range= ± 3 Abs 17. Operating Conditions= 10 at 40 °C, max. 80% relative humidity (non-condensing) 18. Photometric Accuracy= 5 m Abs at 0.0-0.5 Abs <1% at 0.5-2.0 Abs at 546 nm 19. Photometric Linearity= 0.005 - 2 Abs ? 0.01 at > 2 Abs with neutral glass at 546 nm\n20. Stray Light= KI-solution at 220 nm < 3.3 Abs/ < 0.05%\n21. Storage Conditions= -25 to 60 °C max. 80% relative humidity (non-condensing) 22. Enclosure Rating= IP20 with closed lid\n23. Interfaces= USB type A (2), USB type B, Ethernet, RFID module\n24. Warranty= 1 year\n | 1 | No. | |
| 7 | 7 | Autoclave\n1-Horizontal Rectangular High Pressure High Vacuum steam Sterilizer.\n2-Chamber size shall be minimum of 2 feet width x 2 feet height x 4 feet length.3-Should be operated on 400-440V, 3 phasewith neutral, ACpowersupply.4-Chamber volume shall be minimum of 420 liters. 5-Steam generator volume shall be minimum of 60 liters and should be fitted with suitable electrical heater load of 18KW, to produce steam to sterilizer. 6-The sterilizer shall have single door (Hinge type ) with radial lockingusing shooting bolts having high pressure locking safety facility and made of good quality stainless steel304quality. Should provide heat resistant SILICON door gasket withstand upto 140 Deg. C. 7-The sterilizer shall have to draw the water, automatically, when needed in the inbuilt boiler. 8-Thickness of chamber of sterilizer shall be minimum 6mm and to be made of stainless steel 316 qualityis capable to withstand the negative pressure (vaccum) of 24-26’’Hg created by the vaccum pump. 9-Thickness of door of sterilizer shall be minimum of 12mm and to be made of stainless steel 316 quality. 10-Sterilizerjacket shall be made of Boiler quality steel plate with a material thickness of 6-8mm. 11-Glass wool insulation thickness shall be 50mm. Insulation cover shall be made of good quality stainless steel 304 quality. 12-All connecting pipes shall be made of good quality stainless steel. 13-Stand shall be made of Mild steel with anticorrosion paint. 14-The unit shallbe fitted with suitable water ring Vacuum pump. 15-Pressure gauge range shall be 0 to 6 Kg./cm2 . 16-Compound gauge range shall be –1 to 6 Kg/cm2. 17-Safety valve range shall be 0.3 to 3.5kg/cm2. 18-The unit shall be capable of being stored continuously in ambient temperature of 0-50 Deg.C and relative humidity of 15-90%. 19-Suitable validation port shall be provided. 20-Working temperature of sterilizer is 121-134 Deg. C and the corresponding pressure is 1.2-2.1 kg/cm2. 21-Safety features of sterilizers: Doorlocking facility, Low water protection system, Pressure cut off facility and all other necessary safety features. 22-Equipment shall have no sharp edges, will be securely mounted and would provide adequate protection against movingand electrically energizedparts. 23-Controls (e.g.switches, knobs) shall be visible and clearly identified. 24-Labels and markings shall be clear and visible.\n | 1 | No. | |
| 8 | 8 | Digital Auto Burette ( Bottle top Burette) \nCap. 10 ml \nSelf Zero \nDiscription\n• Precision titrations within the error limits of Class A\n• Large, easy-grip hand wheels for sensitive, drop-wise titration\n• Titrating tube can be adjusted horizontally and vertically - providing flexibility when positioning the instrument\n• No switching needed when changing between filling and titration\n• Calibration scheduler saves a date for the next calibration, Auto-Power-Off, Change decimal place settings\n• Easy cleaning, maintenance and part replacement\nCalibration: Calibration certificate from any NABL certified Laboratory required with validity of at least 1 Year. | 3 | No. | |
| 9 | 9 | Benchtop Ion meter (ISE) along with Fluoride,Nitrate Electrode - Make- Hach\nSpecifications PH • Range -2.000 to 20.000 • Resolution 0.1, 0.01, 0.001 • Relative Accuracy ±0.002 Calibration Points Up to 5 • Calibration Editing Yes mV/RmV • Range ±2000.0 • mV Resolution 0.1 \n• Relative Accuracy ±0.2 mV or ±0.05 % of reading whichever is greater • EH ORP Mode Yes \nISE • Range 0 to 19999 • Resolution Up to 3 significant digits • Relative Accuracy ±0.2 mV or ±0.05 % of reading whichever is greater • Units ppm, M, mg/L, %, ppb, none • Calibration Points Up to 5\n• Calibration Editing Yes • Calibration Features Timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability \nTemperature \n• Range -5 to 105 °C, 23 to 221 ºF • Resolution 0.1 • Relative Accuracy ±0.1 • Offset Calibration 1 point \nDatalogging \n• Memory 2000 with time and date stamp • Log Function Manual, ready (include AUTO-READ™), timed • Log Edit Delete individual points, group of points or all I Inputs • pH Electrode BNC, reference pin • ATC Probe 8-pin mini-DIN Output • RS232, USB \nPower \n• AC Adapter Included – universal, 100-240 VAC • Battery Power Optional – 4 AAs • Battery Life 800 hrs Inputs Ph Electrode BNC,reference pin ATC Probe 9-pin mini-DIN Output RS232,USB\n | 1 | No. |
AI Tender Summary
Tender Timeline
Feb 05, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 15, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 16, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer