Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #26865432

Supply Of Digital Electronic Balance , Uv-Vis Spectrophotometer , Digital Turbidity Meter , Hot Air Oven , Auto Burette , Digital Micropipette , Autoclave Etc . Complete In All Respect .

Issued by Government Departments · District Laboratory, Rewari, Haryana
Tender Value
9.95 Lakhs
Estimated cost
Bid Submission
15 Feb 2021
0 days left
EMD
19900
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
District Laboratory, Rewari → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Of Digital Electronic Balance , Uv-Vis Spectrophotometer , Digital Turbidity Meter , Hot Air Oven , Auto Burette , Digital Micropipette , Autoclave Etc . Complete In All Respect .

BOQ

Name of Work: Supply of Digital Electronic Balance, UV-VIS Spectrophotometer, Digital Turbidity Meter, Hot Air Oven, Auto Burette, Digital Micropipette, Autoclave etc. complete in all respect.
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Digital Electronic Balance Make Make: Ohaus/Shimazo/ Mettler Toledo Capacity 220gm., Readability 0.1mg, Pan Size(mm) : 85-91 mm dia High Contrast, Large Backlite LCD display for easy viewing with A.E.P. (Advanced Eye Protection) Standard RS 232 C interface. Automatic Internal calibration Various weighing units like gm, mg, ct, oz, dwt, mom, GN User selectable stability and filter level. \n Calibration: Calibration certificate from any NABL certified Laboratory required with validity of at least 1 Year. \n1No.
22Digital Turbidity Meter: Hach Specifications • Turbidity Range 0 to 1000 NTU • Resolution & Accuracy 0.01 NTU (0 to 9.99 NTU); 0.1 NTU (10 to 99.9 NTU); 1 NTU (100 to 1000 NTU) & ± 2% of measured range + 0.01 NTU • No. of Calibration Points Up to 3 points • Calibration Options 4 points (0.02, 10, 100, 1000) • Light Source White light (tungsten) • Response Time < 6 seconds • Power 12 VDC, using AC adapters 110 VAC or 220 VAC, 50/60 Hz\n1No.
33HOT AIR OVEN -Make Iso certified Company (Specifications)\n• Inner Chamber SIZE:18”X18”X18”inch(LxWxD)\n• Double walled inner chamber available in stainless steel with grade304. \n• Outer chamber made of Stainless Steeel\n• Glass wool/ PUF insulation to prevent temperature loss. \n• Outer double wall door is provided with gas kit.\n• Stainless steel removable & adjustable shelves .\n• No. of Shelves-3nos\n• Digital display with mains ON/OFF, switch indicating lamps & Fuse \n• Digital microprocessor based PID Temp controller with LED Display \n• accuracy of temperature +/- 0.5 degree\n• Temperature range adjustable from Room Temp. to2600C (resolution 0.10C)\n• Air flow systems providing Blower for even distribution of temperature.tt\n• Safety thermostat to prevent over heat. \n• Electric Supply:220/230V AC,50/60 Hz,2500watt\nCalibration Certifiate From NABL Certified Lab Required\n1No.
44Digital Micro Pipette\nVariable Volume 0.05 ml to 5 ml\nMake : Mettler Toledo/ Borosil2No.
55Digital Micro Pipette\nVariable Volume 10 ml to 20 ml\nMake : Mettler Toledo/ Borosil\n2No.
66Spectrophotometer - Pre-programmed Water AnalyzerMake - HACH (DR 6000) With 1 No. Hachpack (Nitrate,Iron,Sulphate,Flouride)\n1. Operating Mode= Transmittance (%), absorbance and concentration (wavelength, time) 2. Source Lamp= Tungsten (visible range), deuterium\n3. Display= TFT 7 inch WVGA color touch 4. Data Logger= 5000 data points (result, date, time, sample-ID, user-ID) (UV range) 5. Wavelength Range= 190 - 1100 nm 6. Preprogrammed Methods= > 250\n7. Wavelength A+C79ccuracy= ± 1 nm User Programs 200\n8. Wavelength Reproducibility= < 0.1 nm nm 9. Sample Cell Compatibility= Rectangular: 10, 20, 30, 50 mm, 1 inch; round: 13 mm, 16 mm, 1 inch 10. Wavelength Resolution= 0.1 nm 11. Wavelength Selection= Automatic, based on method selection 12. Spectral Bandwidth= 2 nm 13. Dimensions (H x W x D)= Optional 100 mm rectangular cell with additional adapter 8.5 in x 19.7 in x 18.1 in (215 mm x 500 mm x 460 mm) 14. Scanning Speed= 900 nm/min (in 1 nm steps)\n15. Weight= 24.25 lbs. (11 kg) 16. Photometric Measuring Range= ± 3 Abs 17. Operating Conditions= 10 at 40 °C, max. 80% relative humidity (non-condensing) 18. Photometric Accuracy= 5 m Abs at 0.0-0.5 Abs <1% at 0.5-2.0 Abs at 546 nm 19. Photometric Linearity= 0.005 - 2 Abs ? 0.01 at > 2 Abs with neutral glass at 546 nm\n20. Stray Light= KI-solution at 220 nm < 3.3 Abs/ < 0.05%\n21. Storage Conditions= -25 to 60 °C max. 80% relative humidity (non-condensing) 22. Enclosure Rating= IP20 with closed lid\n23. Interfaces= USB type A (2), USB type B, Ethernet, RFID module\n24. Warranty= 1 year\n1No.
77Autoclave\n1-Horizontal Rectangular High Pressure High Vacuum steam Sterilizer.\n2-Chamber size shall be minimum of 2 feet width x 2 feet height x 4 feet length.3-Should be operated on 400-440V, 3 phasewith neutral, ACpowersupply.4-Chamber volume shall be minimum of 420 liters. 5-Steam generator volume shall be minimum of 60 liters and should be fitted with suitable electrical heater load of 18KW, to produce steam to sterilizer. 6-The sterilizer shall have single door (Hinge type ) with radial lockingusing shooting bolts having high pressure locking safety facility and made of good quality stainless steel304quality. Should provide heat resistant SILICON door gasket withstand upto 140 Deg. C. 7-The sterilizer shall have to draw the water, automatically, when needed in the inbuilt boiler. 8-Thickness of chamber of sterilizer shall be minimum 6mm and to be made of stainless steel 316 qualityis capable to withstand the negative pressure (vaccum) of 24-26’’Hg created by the vaccum pump. 9-Thickness of door of sterilizer shall be minimum of 12mm and to be made of stainless steel 316 quality. 10-Sterilizerjacket shall be made of Boiler quality steel plate with a material thickness of 6-8mm. 11-Glass wool insulation thickness shall be 50mm. Insulation cover shall be made of good quality stainless steel 304 quality. 12-All connecting pipes shall be made of good quality stainless steel. 13-Stand shall be made of Mild steel with anticorrosion paint. 14-The unit shallbe fitted with suitable water ring Vacuum pump. 15-Pressure gauge range shall be 0 to 6 Kg./cm2 . 16-Compound gauge range shall be –1 to 6 Kg/cm2. 17-Safety valve range shall be 0.3 to 3.5kg/cm2. 18-The unit shall be capable of being stored continuously in ambient temperature of 0-50 Deg.C and relative humidity of 15-90%. 19-Suitable validation port shall be provided. 20-Working temperature of sterilizer is 121-134 Deg. C and the corresponding pressure is 1.2-2.1 kg/cm2. 21-Safety features of sterilizers: Doorlocking facility, Low water protection system, Pressure cut off facility and all other necessary safety features. 22-Equipment shall have no sharp edges, will be securely mounted and would provide adequate protection against movingand electrically energizedparts. 23-Controls (e.g.switches, knobs) shall be visible and clearly identified. 24-Labels and markings shall be clear and visible.\n1No.
88Digital Auto Burette ( Bottle top Burette) \nCap. 10 ml \nSelf Zero \nDiscription\n• Precision titrations within the error limits of Class A\n• Large, easy-grip hand wheels for sensitive, drop-wise titration\n• Titrating tube can be adjusted horizontally and vertically - providing flexibility when positioning the instrument\n• No switching needed when changing between filling and titration\n• Calibration scheduler saves a date for the next calibration, Auto-Power-Off, Change decimal place settings\n• Easy cleaning, maintenance and part replacement\nCalibration: Calibration certificate from any NABL certified Laboratory required with validity of at least 1 Year.3No.
99Benchtop Ion meter (ISE) along with Fluoride,Nitrate Electrode - Make- Hach\nSpecifications PH • Range -2.000 to 20.000 • Resolution 0.1, 0.01, 0.001 • Relative Accuracy ±0.002 Calibration Points Up to 5 • Calibration Editing Yes mV/RmV • Range ±2000.0 • mV Resolution 0.1 \n• Relative Accuracy ±0.2 mV or ±0.05 % of reading whichever is greater • EH ORP Mode Yes \nISE • Range 0 to 19999 • Resolution Up to 3 significant digits • Relative Accuracy ±0.2 mV or ±0.05 % of reading whichever is greater • Units ppm, M, mg/L, %, ppb, none • Calibration Points Up to 5\n• Calibration Editing Yes • Calibration Features Timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability \nTemperature \n• Range -5 to 105 °C, 23 to 221 ºF • Resolution 0.1 • Relative Accuracy ±0.1 • Offset Calibration 1 point \nDatalogging \n• Memory 2000 with time and date stamp • Log Function Manual, ready (include AUTO-READ™), timed • Log Edit Delete individual points, group of points or all I Inputs • pH Electrode BNC, reference pin • ATC Probe 8-pin mini-DIN Output • RS232, USB \nPower \n• AC Adapter Included – universal, 100-240 VAC • Battery Power Optional – 4 AAs • Battery Life 800 hrs Inputs Ph Electrode BNC,reference pin ATC Probe 9-pin mini-DIN Output RS232,USB\n1No.

AI Tender Summary

OUR REF NO 26865432
AUTHORITY Government Departments
TENDER VALUE 9.95 Lakhs
LAST DATE 15-02-2021
Authority
Authority Name Public Health Engineering Department
Work Description Supply Of Digital Electronic Balance , Uv-Vis Spectrophotometer , Digital Turbidity Meter , Hot Air Oven , Auto Burette , Digital Micropipette , Autoclave Etc . Complete In All Respect .
Basic Detail
Tender No 6855 date 24.12.2020
Bidding Type Tender
Location
City District Laboratory, Rewari
State Haryana
Key Dates
Publish Date 05 Feb 2021
Submission Date 15 Feb 2021
Open Date 16 Feb 2021
Finance
Tender Value 9.95 Lakhs
Tender Fee 1000
EMD 19900
Exemption Not Available
Document List
Notice18.pdf
BOQ_212570.xls
EAD868B0-A6E9-49E6-A940-1C10150D8562.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 05, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 15, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 16, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Notice18.pdf

xls

BOQ_212570.xls

html

EAD868B0-A6E9-49E6-A940-1C10150D8562.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders