Provision Of Storage Accn At Bso Nw Kochi, KOCHI-Kerala

Military Engineer Services-MES has published Provision Of Storage Accn At Bso Nw Kochi. Submission Date for this Tender is 19-02-2021. Storage Chests and Cabinets and Trunks Tenders in KOCHI Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

26854023
Corrigendum : Provision Of Storage Accn At Bso Nw Kochi
Open Tender
Indian
Kerala
KOCHI
19-02-2021

Tender Details

Provision Of Storage Accn At Bso Nw Kochi - 1 Excavating In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth; For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. N Exc 10 Sqm On Plan And N Exc 1.5 M In Depth And Getting Out In Soft / Loose Soil Complete All As Specified And As Directed By Engineer-In-Charge. 2 Returning / Filling In Layers And Ramming In Layers Around Pile Cap, Plinth Beam Etc Using Excavated Soil Incl Sprading, Levelling, Well Ramming In Layers Not Less Than 25Cm Thickcomplete All As Specified And As Directed By Engineer-In-Charge. 3 Removing Excavated Material Exc 1.5Km N.Exc 5Km And Depositing Where Directed At A Level N.Exc 1.5M Above Starting Point Complete All As Specified And As Directed By Engineer-In-Charge. 4 M&L For Pcc ( 1:4:8 ) Type D-2 ( Using 40Mm Graded Stone Aggregate ) In Foundation Filling And Mass Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 5 M&L For Pcc ( 1:2:4 ) Type B-0 Using 12.50Mm Graded Aggregate As In Dpc ( Damp Proof Course ) Complete All As Specified And As Directed By Engineer-In-Charge. 6 M&L For Rcc M-30 Design Mix In Foundations, Including Rafts, Footings, Foundation Beams;Plinth Beams; Bases For Columns, Etc.; Basement Slabs, Under-Reamed Piles And Mass Concretecomplete All As Specified And As Directed By Engineer-In-Charge. 7 M&L For Rcc M-30 Design Mix In Beams, Cantilevers, Bressummers, Lintels Over 1.5M Span Complete All As Specified And As Directed By Engineer-In-Charge. 8 All As Per Item No 6 Here-In-Before But For Columns.. 9 All As Per Item No 6 Here-In-Before But For Roof Slab. 10 M&L For Rcc M-30 Design Mix For Chajjas Complete All As Specified And As Directed By Engineer-In-Charge. 11 M&L For Mild Steel Tmt Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips Complete All As Specified And As Directed By Engineer-In-Charge. 12 M&L For Crs Tmt Bars In Reinforcement 6 To 8Mm Dia And Over Including Cut To Length , Bend To Required Shape , Cranking / Hooking Ends If Necessary And Binding With 0.9Mm Dia Ms Wire Annealed Or Welding So As To Secure The Bar Firmly In Position / Required Shape Complete All As Specified And As Directed By Engineer-In-Charge. 13 M&L For Mild Steel Tmt Bars 5Mm Dia And Over Upto And Including 10Mm Dia In Stirrups, Spacers And Binders Complete All As Specified And As Directed By Engineer-In-Charge. 14 Use And Waste Formwork To Sides Of Concrete Rough Finished Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits ( If Any ) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter Complete All As Specified And As Directed By Engineer-In-Charge. 15 Use And Waste Formwork To Sides Of Column For Rough Finished Surfaces Of Concrete Complete All As Specified And As Directed By Engineer-In-Charge. 16 Use And Waste Formwork To Sides Fair Finished And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc.Complete All As Specified And As Directed By Engineer-In-Charge. 17 Use And Waste Formwork To Soffits Of Suspended Slabs Such As Roof Slabs, Floor Slabs, Landings And Similar Work; Not Exceeding 200Mm Thick For Rough Finished Surfaces Of Concrete ( Horizontal Or Sloping ) Complete All As Specified And As Directed By Engineer-In-Charge. 18 Use And Waste Of Formwork To Chullah Hoods, Chajjas, Troughs And Similar Items Including Edges Complete All As Specified And As Directed By Engineer-In-Charge. 19 M&Lfor Moorum / Red Bajri Filling In Floor Or Paving Laid In Layers N Exc 15 Cm Thick Spread Levelled And Rammed Including Watering Complete All As Specified And As Directed By Engineer-In-Charge. 20 M&L For Pre-Cast Cement Concrete Block Masonry With Solid Blocks Of Cement Concrete Exc. 10 Cm Width And Setting In Cement Mortar 1:6 Type C-1, 1:3:6 ( Using 20 Mm Graded Stone Aggregate ) Complete All As Specified And As Directed By Engineer-In-Charge. 21 M& L For 10Mmm Thick Cement Plaster In Cm 1:6 On Fair Surfaces Of Brick Work Or Concrete Surfaces, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 22 M&L For Rendering 5Mm Thick In Cm 1:4 Using Liquid Wpc Over 10Mmm Thick Rendering In Cm 1:6 On Fair Surfaces Of Brick Work Or Concrete Surfaces, Finished Even And Fair Without Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 23 M&L For 5 Mm Thick Rendering In Cement Mortar 1:3 On Fair Faces Of Of Ceiling Surfaces Complete All As Specified And As Directed By Engineer-In-Charge. 24 Supply Only Integral Water Proofing Compound Complete All As Specified And As Directed By Engineer-In-Charge. 25 M&L For Preparing New And Old Surfaces And Applying 3Mm Thick Wall Care Putty And Two Coat Of Acrylic Interior Emulsion Over A Coat Of Primer Complete All As Specified And As Directed By Engineer-In-Charge. 26 M&L For Preparation Of New Plastered Surfaces Of Wall And Applying Two Coat Of Apex Ultima Protek Top Coat Over A Coat Of Protek Base Coat Complete All As Specified And As Directed By Engineer-In-Charge. 27 M&L For Preparation Of New Decorated Surfaces Of Ceiling And Applying Three Coat Of White Wash Complete All As Specified And As Directed By Engr-In-Charge. 28 M&L For Hardcore Of Gauge N Exc. 63 Mm, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface Complete All As Specified And As Directed By Engineer-In-Charge. 29 M&L For 100 Mm Thick Pcc Type D-2, 1:4:8 ( 40Mm Graded Aggregate ) For Sub Base To Floor, Finished Even And Smooth With Out Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 30 M&L For 50 Mm Thick Pcc Type B-2, 1:2:4 ( 40Mm Graded Aggregate ) Hard Standing, Finished Even And Smooth With Out Using Extra Cement Complete All As Specified And As Directed By Engineer-In-Charge. 31 M&L For 15Mm Thick Screed Bed Or Beding Layer In Cement Mortar ( 1:4 ) On Floors For Laying Floor Finish Complete All As Specified And As Directed By Engineer-In-Charge. 32 M&L For Non Skid Coloured Ceramic Tiles 7 To 8 Mm Thick Square / Rectangular Area Of Each Tiles Exceeding 0.06 Sqm But Not Exceeding 0.11 Sqm In Floor Etc, Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match The Tiles Including Provision Of Cm Screed 15 Mm Thick In Cm ( 1:6 ) Complete All As Specified And As Directed By Engineer-In-Charge. 33 All As Per Item No. 32 Here-In-Before But In Vertical Surfaces As Dados / Skirting But Glazed Ceramic Tiles Of Size 300 X 200 Mm X 7 Mm Thick Including Provision Of Backing Coat 10 Mm Thick In Cm ( 1:4 ) . Complete All As Specified And As Directed By Engineer-In-Charge. 34 S&F Anodised Powder Coated Aluminium Frame For Doors, Windows, Ventilators Partitions With One Or More Rebates Including Joining Cleat For Fixing Etc.Complete All As Specified And As Directed By Engineer-In-Charge. 35 S&F In Repairs Anodised Aluminium Door Frame Without Sash Bar, Including All Necessary Jointing Cleats, Hold Fasts, Hinges With Fixing Clips, Rubber Gasket, Anodized Snap Beading, Anodized Aluminium Fittings, Locking Arrangement Etc. Based On Hindalco Catalogue No: N 1. 9258 - 50X44.50X1.80Mm = Door Vertical. N 2. 9286 - 50X45x1.50Mm = Door Top & Middle. N 3. 9246 - 100X44.50X1.85 = Door Bottom. N Complete All As Directed By The Enginner-In-Charge. 36 S&F Anodised Aluminium Sliding Window And Ventilator Frame Double Shutter ( Glass And Wire Mesh ) Without Sash Bar, Including All Necessary Jointing Cleats, Hold Fasts, Rubber Gasket, Anodised Snap Beading, Anodised Aluminium Fitting Such As Aluminium Fitting Such As F Channel If Required For Wire Mesh Or Aluminium Grill, Aluminium Handle, Locking Arrangement Tec Based On Hindalco Catalogue No: N 1. 4087 - 92.36X29.70X1.20Mm = 3 Track Bottom. N 2. 4099 - 92.36X29.70X1.20Mm = 3 Track Side & Top . N 2. 9395 - 39.00X20.00X1.10Mm = Shuter Vertical N 3. 3994 - 41.00X20.00X1.20 = Shutter Top & Botam. N 4. 9779 - 39.00X20.00X1.16Mm = Shutter Vertical Inter Lock Complete All As Specified And As Directed By Engineer-In-Charge. 37 S&F Anodised Aluminium Grill, Having Mesh Size 50X50mm Made Out Of 6Mm Wide, 3Mm Thickaluminium Section Including U Clips And All Assessory Complete All As Directed By Engr-In-Charge. 38 S&F 9Mm Thick Pre Laminated Praticle Board Interior Grade Prelaminated Both Sides Complete All As Specified And As Directed By Engineer-In-Charge. 39 S&F 5 Mm Thick Plain Sheet Glass Ordinary Quality Glazing With Oil Putty And Glazing Pins / Spring Clips In Square Not Exceeding 0.50 Sqm In Each Pane Complete All As Specified And As Directed By Engineer-In-Charge. 40 S&F Double Action Floor Spring Hydraulically Regulated Made Up Of Minimum 1.25 Mm Thick Aluminium Alloy Sheet Foundation Box, Main Body With Stainless Steel Cover, Governing Pivot Made Of Brass, Other Parts Made Of Mild Steel Heavy Duty With Making Sutaible Place For Fixing And Make Good To Match The Existing Surface Complete All As Specified And As Directed By Engineer-In-Charge. 41 S&F Stainless Steel Wire Cloth, 0.63Mm Nominal Dia Of Wire And Average Width Of Aperture 1.4Mm And Fixed With Stainless Steel Wire Staples To Wooden Shutters Or Steel Frames Including Wooden Beads Complete All As Specified And As Directed By Engineer-In-Charge. 42 M&L For 2Nd Class Hard Wood Palin , Solid , Straight Chowkats And Frames , Wrought, Framed Rebated On The Solid, Rounded Or Chamfered, Put Together With Glue Pinned At Joints, Complete All As Specified And As Directed By Engineer-In-Charge. 43 S&F 40Mm Thick, 2Nd Class Hw Plain, Framed, Panelled Shutters ( Any Number Of Panels ) , With Panels Of Timber Flat On Both Sides ( Feather Edged ) , Or Of Veneered Particle Board Medium Density, Wood Particle Board With Commercial Face Veneers Complete All As Specified And As Directed By Engineer-In-Charge. N 44 S&F 30Mm Thick, 2Nd Class Hw Glazed And Skeleton Shutters, Open Rebated And Prepared To Receive Glass, Gauze, Etc. Divided Into Squares, With Plain, Chamfered Or Rounded, Mitred And Rebated Sash Bars Any Numbers, Edges Of Framing Plain, Chamfered Or Rounded, Fitted With Cut And Mitred Beads For Securing Glass, Etc. Complete All As Specified And As Directed By Engineer-In-Charge. N 45 M&L For Att For Treating The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface 46 M& L For Att For Treating The Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface ( Area Of The Sub Structure In Contact With Backfill To Be Measured ) 47 M&L For Mild Steel Flat Iron Of Size 25 X 3Mm As In Hold Fast For Fixing Door Frame Etc And Other Similar Items Conforming To Fe-410-0 Or Fe-310-0 Complete All As Psecified And As Directed By Engr -In-Charge. 48 M&L For Pcc 1:2:4 Type B-1 ( Using 20Mm Graded Stone Aggregate ) For Iimbeding Of Hold Fast Etc.Including Necessary Form Work Complete All As Psecified And As Directed By Engr -In-Charge. 49 S&F 125Mm Butt Hinges, Cast Brass, With Mild Steel Hinge Pin, Bright Polished And Fixed, Type B-11 Complete All As Psecified And As Directed By Engr -In-Charge. N 50 S&F 150Mm Long Brass Handles, Cast Type, Polished Bright Complete All As Specified And As Directed By Engineer-In-Charge. 51 S&F 150Mm Long Brass Barrel Tower Bolts, With Cast Or Sheet Barrel And Rolled Or Cast Bolts Complete All As Specified And As Directed By Engineer-In-Charge. 52 S&F 250Mm Long Brass, Sliding Door Bolt With Sand Or Die-Cast Brass Hasp, Staple ( Bolt Type ) And Fixing Bolt With Rolled Or Drawn Brass Bolts Complete All As Specified And As Directed By Engineer-In-Charge. 53 M& L For Preparation Of New Wood Surface And Applying Two Coat Of P.U ( Polyurethane ) Wood Polish Complete All As Directed And As Directed By Engr-In-Charge. 54 M&L For Rendering 20 Mm Thick On Concrete / Brick Surfaces In Cm 1:3 Including Wpc As Per Manufacturers Instructions Complete All As Specified And As Directed By Engineer-In-Charge. 55 M&L For Seven Course Water Proofing Treatment Over Rcc Slab By Applying Oil Bound Bitumen Primer @ 0.20 Kg / Sqm Providing And Laying 4Mm Thick App Modified Water Proofing Membrane Of Make Basf / M / S Fosroc / Iwl / Stp Ltd Weighing Not Less Than 4.00 Kg / Sqm Reinforced With Non Woven Polyster Matt Weighing Not Less Than 160 Gm / Sqm Having Soften Point Not Less Than 140Oc Longitudinal Tensile Strength Not Less Than 650 N / 5 Cm Tearing Strength Of 180 N / Torque Application, Applying A Coat Of Blown Grade Hot Bitumen 90 / 15 Over The Membrane @ 1.20 Kg / Sqm Finished With Solar Reflective / Bituminus Aluminium Paint @ 0.10 Kg / Sqm, Keeping A Minimum Of 10 Cm Over Laps And 15 Cm End Lap ( 7 Course - Primer + Bonding Material+ App+Bonding Material+App+Bonding Material+Finishing Coat ) , Complete All As Specified And As Directed By Engineer-In-Charge. 56 S&F Anodized Aluminium Snap Grid Frame Work For False Ceiling All As Specified Including Gi Hangers 6 Mm Dia ( Upto 1200 Mm Length ) Adjusting Level Fixed To Roof Slab By Means Of Ceiling Cleats Made Out Of Gi Flat 40 X 3 Mm Size 60 Mm Long And Expansion Hold Fasterners 12.5Mm Dia 40Mm Longcomplete All As Specified And As Directed By Engineer-In-Charge. 57 S&F 4 Mm Thick Non Asbestos Fibre Cement Building Boards Fixed Or Laid / Inserted To Timber / Gi / Aluminium Framework With Screws Fixed To Ceiling Frame Complete All As Specified And As Directed By Engineer-In-Charge. 58 M&L For Washing Rubbing Old Distemberred Surfaces Of Walls And Applying One Coat Of Oil Bound Distember Complete All As Specified And As Directed By Engineer-In-Charge. 59 M&L For Preparation Of Old Painted Wooden Surfaces Of Any Description Exc 10Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And As Directed By Engineer-In-Charge. 60 Demoilition Of Brick Work Or Stone , Boulder, Pre Cast Pcc Block Masonry Etc Built In Cement Or Lime Mortar Complete All As Specified And As Directed By Engineer-In-Charge. 61 Grubbing Up Tree Trunk Exc. 30 Cm And Nexc 100 Cm Girth Including Cutting Of Trunk Portion Protruding Over Ground, Digging Out Roots, Filling Holes And Leveling Off Ground, Stacking Of Serviceable Material And Removing Of Unserviceable Material To A Distance N Exc. 50 M And Clearing Site Complete All As Specified And As Directed By Engineer-In-Charge. 62 Material And Labour For Point Wiring For One Light / Fan Point With 1.5 Sqmm Pvc Insulated ( Frlsh ) Unsheathed Copper Conductor Multistranded 1100 Volts Grade Controlled By One Way Switch Including 1.5 Sqmm Pvc ( Frlsh ) Insulated Unsheathed Copper Cable Multistrand Conductor 1100 Volts Grade For Continuity Conductor Including Connected To Common Earth Dolly Drawn Through And Including Rigid Pvc Conduit Medium Grade Isi Marked Concealed Of Suitable Size With All Accessories And Sunken Box Of 1.6Mm Thick Pressed Steel Box Factory Made For Mounting Of Switch, Socket And Fan Regulator With Modular Frames Covers Including Chase Cutting And Making Good To The Disturbed Surface And Matching To The Existing Finishes Specifications Complete All As Specified And As Directed 63 All As Per Item No.62 Here In Before But For One 5 Pin 5 Amp Socket Outlet Point On Independent Board Complete All As Specified And Directed. 64 All As Per Item No.62 Here In Before But For One 5 Pin 5 Amp Socket Outlet Point On Same Board Complete All As Specified And Directed. 65 All As Per Item No.62 Here In Before But Using With 2.5 Sqmm Copper Conductor Cables Multistranded ( Frlsh ) Pvc Insulated, Unsheathed Cable And Including 2.5 Sqmm Copper Conductor Cable Multistranded ( Frlsh ) Pvc Insulated And Unsheathed Cable As Earth Continuity Wire And Connecting To Common Earth Dolly For One 6 Pin 15 Amps Socket Outlet Point On Independent Board Complete All As Specified And Directed. 66 Material And Labour For Submain Wiring With 2 Runs 10 Sqmm Single Core, Pvc Insulated Unsheathed, Multistranded Copper Conductor Frlsh Cable 1100 Volts Grade Drawn Through Pvc Conduit With All Accessories On Surface, One Run Of 10 Sqmm Cable Single Core Pvc Insulated, Unsheathed, 1100 Volts Grade Multistranded Copper Conductor Frlsh Cable As Earth Continuity Conductor And Making Good The Disturbed Surface To Match With The Existing Complete All As Specified And Directed. Nnote :- Two Runs Of 10 Sqmm Size Pvc Copper Cable, One Run Of 10 Sqmm Size Pvc Copper Cable And One Run Of Pvc Conduit Shall Be Measured As One Unit Length. 67 S&F Mcb Spn 40 Amp, 240 Volts 50 Hz, 10 Ka Breaking Capacity, B Series With All Incoming And Outgoing Connections Withy Proper Size Of Lugs Complete All As Specified And Directed. Cat Part No. Au 10Ss0403b Of L&T Or Legrand. Abb. 68 S&F Mcb Sp 6 To 32 Amps, 240 Volts 50 Hz, 10 Ka Breaking Capacity, B Series With All Incoming And Outgoing Connections Withy Proper Size Of Lugs Complete All As Specified And Directed. Cat Part No. Au 10S100063b To Au 10S10323b Of L&T Or Legrand. Abb. 69 S&F Modular Type Sockets 6 Amp-2 / 3 Pin Combined 2 Module Complete All As Specified & Directed Of Make Of Legrand, L&T And Philips. 70 S&F Switch Modular Typr, Single Pole, 6 Amps, One Way All As Sper Specified And Directed Of Make Of Legrand, L&T And Philips. 71 S&F Modular Sockets 6 Amp / 16 Amps, 2 / 3 Pin Combined 2 Module Complete All As Specified Of Make Of Legrand, L&T And Philips. 72 S&F Switch Modular Type 1 Module, 16 Amps, One Way All As Per Specified And Directed Of Make Of Legrand, L&T And Philips. 73 S&F Ceiling Rose Surface Bakelite 65 X 50 Mm 3 Terminals 240 Volt 50 Hz Complete All As Specified And Directed Of Make Of Legrand, L&T And Philips. 74 S&F Mcb Spn Db 8 Ways Double Door Metal Door Ip 43 Protection Typoe Suitable For 200Amp 240 Volts 50 Hz Iuncluding All Electrical Connections Complete All As Specified And Directed Of Make Of Legrand, L&T And Philips. 75 S&F Modular Fan Step Regulator 120 W, 240 V, Complete Alll As Specified And As Directed Of Make Of Legrand, L&T And Philips. 76 S&F Ceiling Fan, Curved Blade, Colour Pearl White Silver Complete With Accessories 230 V, 1200 Mm Sweep, Bee 5 Star Rated Model - Troika Of Havells , Crompton, Bajaj, Orient, Complete Alll As Specified And As Directed. 77 S&F In Repair; 20W Led T-8 Tubular Lamp Extruded Aluminium / Polycorbonate Body And Diffuser And In Built Driver Including Mirrorlite Batten Suitable For T-8 Lamp Suitabl;E Connection Nfrom Ceiling Rose To Tube Lamp All As Specified And As Directed. Cat Part No. Ltt8-20 And Dmln1lt8-18 Of Crompton , Philips And Bajaj. 78 S&F In Repair; Led T-8 Stelllux-H-Recess Mounted Signature Series Premium Commercial Luminaire 36 W , 50Hz, 220 Volts, 5700 K Led Down Lighter 2X2 Complete All As Specified And As Directed. Cat Part No. Lctrh-36-Cdl Of Crompton , Philips And Bajaj.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Feb-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-02-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 52000.0 /-
Tender Value
INR 26 Lakhs /-

BOQ Items

Name of Work :- PROVISION OF STORAGE ACCN AT BSO (NW) KOCHI
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts,wells,cesspits,manholes,pier holes,etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-Charge. 60 Cum
2 2 Returning/filling in layers and ramming in layers around pile cap,plinth beam etc using excavated soil incl sprading,levelling,well ramming in layers not less than 25cm thickcomplete all as specified and as directed by Engineer-in-Charge. 32 Cum
3 3 Removing excavated material exc 1.5KM n.exc 5KM and depositing where directed at a level n.exc 1.5m above starting point complete all as specified and as directed by Engineer-in-Charge. 28 Cum
4 4 M&L for PCC (1:4:8) type 'D-2' (using 40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-Charge. 6.5 Cum
5 5 M&L for PCC (1:2:4) type B-0 using 12.50mm graded aggregate as in DPC (damp proof course)complete all as specified and as directed by Engineer-in-Charge. 0.45 Cum
6 6 M&L for RCC M-30 design mix in Foundations, including rafts,footings, foundation beams;plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concretecomplete all as specified and as directed by Engineer-in-Charge. 18.5 Cum
7 7 M&L for RCC M-30 design mix in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by Engineer-in-Charge. 10 Cum
8 8 All as per item No 6 here-in-before but for columns.. 6.5 Cum
9 9 All as per item No 6 here-in-before but for roof slab. 12.5 Cum
10 10 M&L for RCC M-30 design mix for Chajjas complete all as specified and as directed by Engineer-in-Charge. 0.8 Cum
11 11 M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. 2550 Kg
12 12 M&L for CRS TMT bars in reinforcement 6 to 8mm dia and over including cut to length , bend to required shape , cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and as directed by Engineer-in-Charge. 230 Kg
13 13 M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed by Engineer-in-Charge. 800 Kg
14 14 Use and waste formwork to sides of concrete rough finished foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed by Engineer-in-Charge. 50 Sqm
15 15 Use and waste formwork to sides of column for rough finished surfaces of concrete complete all as specified and as directed by Engineer-in-Charge. 108 Sqm
16 16 Use and waste formwork to sides fair finished and soffits of floor or roof beams, beam haunchings,girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.complete all as specified and as directed by Engineer-in-Charge. 60 Sqm
17 17 Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick for rough finished surfaces of concrete (Horizontal or sloping)complete all as specified and as directed by Engineer-in-Charge. 110 Sqm
18 18 Use and waste of Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed by Engineer-in-Charge. 9 Sqm
19 19 M&Lfor moorum/red bajri filling in floor or paving laid in layers n exc 15 cm thick spread levelled and rammed including watering complete all as specified and as directed by Engineer-in-Charge. 30 Cum
20 20 M&L for pre-cast cement concrete block masonry with solid blocks of cement concrete exc. 10 cm width and setting in cement mortar 1:6 type C-1, 1:3:6 (using 20 mm graded stone aggregate) complete all as specified and as directed by Engineer-in-Charge. 40 Cum
21 21 M& L for 10mmm thick cement plaster in CM 1:6 on fair surfaces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. 155 Sqm
22 22 M&L for rendering 5mm thick in CM 1:4 using liquid WPC over 10mmm thick rendering in CM 1:6 on fair surfaces of brick work or concrete surfaces, finished even and fair without using extra cement complete all as specified and as directed by Engineer-in-Charge. 140 Sqm
23 23 M&L for 5 mm thick rendering in cement mortar 1:3 on fair faces of of ceiling surfaces complete all as specified and as directed by Engineer-in-Charge. 120 Sqm
24 24 Supply only Integral water proofing compound complete all as specified and as directed by Engineer-in-Charge. 10 Kg
25 25 M&L for preparing new and old surfaces and applying 3mm thick wall care putty and two coat of acrylic interior emulsion over a coat of primer complete all as specified and as directed by Engineer-in-Charge. 155 Sqm
26 26 M&L for preparation of new plastered surfaces of wall and applying two coat of Apex ultima protek top coat over a coat of protek base coat complete all as specified and as directed by Engineer-in-Charge. 130 Sqm
27 27 M&L for preparation of new decorated surfaces of ceiling and applying three coat of white wash complete all as specified and as directed by Engr-in-Charge. 120 Sqm
28 28 M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer-in-Charge. 10 Cum
29 29 M&L for 100 mm thick PCC type D-2, 1:4:8 (40mm graded aggregate) for Sub base to floor, finished even and smooth with out using extra cement complete all as specified and as directed by Engineer-in-Charge. 96 Sqm
30 30 M&L for 50 mm thick PCC type B-2, 1:2:4 (40mm graded aggregate) hard standing, finished even and smooth with out using extra cement complete all as specified and as directed by Engineer-in-Charge. 96 Sqm
31 31 M&L for 15mm thick screed bed or beding layer in cement mortar (1:4) on floors for laying floor finish complete all as specified and as directed by Engineer-in-Charge. 96 Sqm
32 32 M&L for non skid coloured ceramic tiles 7 to 8 mm thick square/rectangular area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including provision of CM screed 15 mm thick in CM (1:6) complete all as specified and as directed by Engineer-in-Charge. 96 Sqm
33 33 All as per item No. 32 here-in-before but in vertical surfaces as dado's/skirting but glazed ceramic tiles of size 300 x 200 mm x 7 mm thick including provision of backing coat 10 mm thick in CM (1:4). complete all as specified and as directed by Engineer-in-Charge. 6 Sqm
34 34 S&F Anodised powder coated aluminium frame for doors, windows, ventilators partitions with one or more rebates including joining cleat for fixing etc.complete all as specified and as directed by Engineer-in-Charge. 20 Kg
35 35 S&F in repairs anodised aluminium door frame without sash bar, including all necessary jointing cleats, hold fasts, hinges with fixing clips, rubber gasket, anodized snap beading, anodized aluminium fittings, locking arrangement etc. based on Hindalco catalogue No: \n 1. 9258 - 50x44.50x1.80mm = Door Vertical.\n 2. 9286 - 50x45x1.50mm = Door top & middle.\n 3. 9246 - 100x44.50x1.85 = Door Bottom.\n complete all as directed by the Enginner-in-charge. 2 Sqm
36 36 S&F anodised aluminium sliding window and ventilator frame double shutter (Glass and wire mesh) without sash bar, including all necessary jointing cleats, hold fasts, rubber gasket, anodised snap beading, anodised aluminium fitting such as aluminium fitting such as 'F' channel if required for wire mesh or aluminium grill, aluminium handle, locking arrangement tec based on Hindalco catalogue No: \n 1. 4087 - 92.36x29.70x1.20mm = 3 Track Bottom. \n 2. 4099 - 92.36x29.70x1.20mm = 3 Track Side & Top .\n 2. 9395 - 39.00x20.00x1.10mm = Shuter Vertical\n 3. 3994 - 41.00x20.00x1.20 = Shutter Top & Botam.\n 4. 9779 - 39.00x20.00x1.16mm = Shutter Vertical Inter Lock complete all as specified and as directed by Engineer-in-Charge. 5 Sqm
37 37 S&F anodised aluminium grill, having mesh size 50x50mm made out of 6mm wide, 3mm thickaluminium section including 'U' clips and all assessory complete all as directed by Engr-in-Charge. 6 Sqm
38 38 S&F 9mm thick pre laminated praticle board interior grade prelaminated both sides complete all as specified and as directed by Engineer-in-Charge. 1 Sqm
39 39 S&F 5 mm thick plain sheet glass ordinary quality glazing with oil putty and glazing pins/spring clips in square not exceeding 0.50 Sqm in each pane complete all as specified and as directed by Engineer-in-Charge. 7 Sqm
40 40 S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty with making sutaible place for fixing and make good to match the existing surface complete all as specified and as directed by Engineer-in-Charge. 1 Each
41 41 S&F stainless steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.4mm and fixed with stainless steel wire staples to wooden shutters or steel frames including wooden beads complete all as specified and as directed by Engineer-in-Charge. 6 Sqm
42 42 M&L for 2nd class hard wood Palin , solid , straight chowkats and frames , wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed by Engineer-in-Charge. 0.2 Cum
43 43 S&F 40mm thick, 2nd class HW plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers complete all as specified and as directed by Engineer-in-Charge.\n 6 Sqm
44 44 S&F 30mm thick, 2nd class HW glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. complete all as specified and as directed by Engineer-in-Charge.\n 6 Sqm
45 45 M&L for ATT for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface 95 Sqm
46 46 M& L for ATT for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) 25 Sqm
47 47 M&L for mild steel flat iron of size 25 x 3mm as in hold fast for fixing door frame etc and other similar items conforming to Fe-410-0 or Fe-310-0 complete all as psecified and as directed by Engr -in-charge. 10 Kg
48 48 M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) for iimbeding of hold fast etc.including necessary form work complete all as psecified and as directed by Engr -in-charge. 0.7 Cum
49 49 S&F 125mm Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type B-11 complete all as psecified and as directed by Engr -in-charge.\n 12 Each
50 50 S&F 150mm long Brass handles, cast type, polished bright complete all as specified and as directed by Engineer-in-Charge. 8 Each
51 51 S&F 150mm long Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts complete all as specified and as directed by Engineer-in-Charge. 8 Each
52 52 S&F 250mm long Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts complete all as specified and as directed by Engineer-in-Charge. 4 Each
53 53 M& L for preparation of new wood surface and applying two coat of P.U (Polyurethane) Wood Polish complete all as directed and as directed by Engr-in-Charge. 15 Sqm
54 54 M&L for rendering 20 mm thick on concrete/ brick surfaces in CM 1:3 including WPC as per manufacturer's instructions complete all as specified and as directed by Engineer-in-Charge. 110 Sqm
55 55 M&L for Seven course water proofing treatment over RCC slab by applying oil bound bitumen primer @ 0.20 kg/Sqm providing and laying 4mm thick APP modified water proofing membrane of make BASF/M/S Fosroc/IWL/STP Ltd weighing not less than 4.00 kg/sqm reinforced with non woven polyster matt weighing not less than 160 gm/Sqm having soften point not less than 140oC longitudinal tensile strength not less than 650 N/ 5 cm tearing strength of 180 N/ Torque application, applying a coat of blown grade hot bitumen 90/15 over the membrane @ 1.20 kg/Sqm finished with solar reflective/ bituminus aluminium paint @ 0.10 kg/Sqm, keeping a minimum of 10 cm over laps and 15 cm end lap (7 course - Primer + Bonding Material+ APP+Bonding material+APP+Bonding material+Finishing coat), complete all as specified and as directed by Engineer-in-Charge. 110 Sqm
56 56 S&F Anodized aluminium snap grid frame work for false ceiling all as specified including GI hangers 6 mm dia (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasterners 12.5mm dia 40mm longcomplete all as specified and as directed by Engineer-in-Charge. 80 Sqm
57 57 S&F 4 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws fixed to ceiling frame complete all as specified and as directed by Engineer-in-Charge. 80 Sqm
58 58 M&L for washing rubbing old distemberred surfaces of walls and applying one coat of oil bound distember complete all as specified and as directed by Engineer-in-Charge. 140 Sqm
59 59 M&L for preparation of old painted wooden surfaces of any description exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge. 35 Sqm
60 60 Demoilition of brick work or stone , boulder, pre cast PCC block masonry etc built in cement or lime mortar complete all as specified and as directed by Engineer-in-Charge. 0.7 Cum
61 61 Grubbing up tree trunk exc. 30 cm and nexc 100 cm girth including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site complete all as specified and as directed by Engineer-in-Charge. 2 Each
62 62 Material and labour for point wiring for one light/fan point with 1.5 sqmm PVC insulated (FRLSH) unsheathed copper conductor multistranded 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FRLSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity conductor including connected to common earth dolly drawn through and including rigid PVC conduit medium grade ISI marked concealed of suitable size with all accessories and sunken box of 1.6mm thick pressed steel box factory made for mounting of switch, socket and fan regulator with modular frames covers including chase cutting and making good to the disturbed surface and matching to the existing finishes specifications complete all as specified and as directed 26 per point
63 63 All as per item No.62 here in before but for one 5 pin 5 Amp socket outlet point on independent board complete all as specified and directed. 8 per point
64 64 All as per item No.62 here in before but for one 5 pin 5 Amp socket outlet point on same board complete all as specified and directed. 4 per point
65 65 All as per item No.62 here in before but using with 2.5 sqmm copper conductor cables multistranded (FRLSH) PVC insulated, unsheathed cable and including 2.5 sqmm copper conductor cable multistranded (FRLSH) PVC insulated and unsheathed cable as earth continuity wire and connecting to common earth dolly for one 6 pin 15 Amps socket outlet point on independent board complete all as specified and directed. 4 per point
66 66 Material and labour for submain wiring with 2 runs 10 Sqmm single core, PVC insulated unsheathed, multistranded copper conductor FRLSH cable 1100 volts grade drawn through PVC conduit with all accessories on surface, one run of 10 sqmm cable single core PVC insulated, unsheathed, 1100 Volts grade multistranded copper conductor FRLSH cable as earth continuity conductor and making good the disturbed surface to match with the existing complete all as specified and directed.\nNote :- Two runs of 10 sqmm size PVC copper cable, One run of 10 sqmm size PVC copper cable and one run of PVC conduit shall be measured as one unit length. 30 RM
67 67 S&F MCB SPN 40 Amp, 240 Volts 50 Hz, 10 KA breaking capacity, 'B' series with all incoming and outgoing connections withy proper size of lugs complete all as specified and directed. Cat Part No. AU 10SS0403B of L&T or Legrand. ABB. 1 Each
68 68 S&F MCB SP 6 to 32 Amps, 240 Volts 50 Hz, 10 KA breaking capacity, 'B' series with all incoming and outgoing connections withy proper size of lugs complete all as specified and directed. Cat Part No. AU 10S100063B to AU 10S10323B of L&T or Legrand. ABB. 6 Each
69 69 S&F modular type sockets 6 amp-2/3 pin combined 2 module complete all as specified & directed of make of Legrand, L&T and Philips. 12 Each
70 70 S&F switch modular typr, single pole, 6 Amps, one way all as sper specified and directed of make of Legrand, L&T and Philips. 38 Each
71 71 S&F Modular sockets 6 Amp/16 Amps, 2/3 pin combined 2 module complete all as specified of make of Legrand, L&T and Philips. 4 Each
72 72 S&F switch modular type 1 module, 16 Amps, one way all as per specified and directed of make of Legrand, L&T and Philips. 4 Each
73 73 S&F ceiling rose surface bakelite 65 x 50 mm 3 terminals 240 Volt 50 Hz complete all as specified and directed of make of Legrand, L&T and Philips. 26 Each
74 74 S&F MCB SPN DB 8 ways double door metal door IP 43 protection typoe suitable for 200Amp 240 Volts 50 Hz iuncluding all electrical connections complete all as specified and directed of make of Legrand, L&T and Philips. 1 Each
75 75 S&F modular fan step regulator 120 W, 240 V, complete alll as specified and as directed of make of Legrand, L&T and Philips. 2 Each
76 76 S&F ceiling fan, curved blade, colour pearl white silver complete with accessories 230 V, 1200 mm sweep, BEE 5 star rated model - Troika of havells ,Crompton, Bajaj, Orient, complete alll as specified and as directed. 6 Each
77 77 S&F in repair; 20W LED T-8 tubular lamp extruded aluminium /polycorbonate body and diffuser and in built driver including mirrorlite batten suitable for T-8 lamp suitabl;e connection nfrom ceiling rose to tube lamp all as specified and as directed. Cat Part No. LTT8-20 and DMLN1Lt8-18 of Crompton , Philips and Bajaj. 4 Each
78 78 S&F in repair; LED T-8 Stelllux-H-recess mounted signature series premium commercial luminaire 36 W , 50Hz, 220 Volts, 5700 K LED down lighter 2'x2' complete all as specified and as directed. Cat Part No. LCTRH-36-CDL of Crompton , Philips and Bajaj. 16 Each
Disclaimer :