Energisation Of 6 Nos . Stw At Kashimpur Mouza Under Hemtabad Block Under Ridf-Xx
Tender Value
Ref. Documents
Estimated cost
Bid Submission
20 Feb 2021
0 days left
EMD
21310
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
HEMTABAD → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Energisation Of 6 Nos . Stw At Kashimpur Mouza Under Hemtabad Block Under Ridf-Xx
BOQ
| Name of Work: Energization of newly drilled 06 Nos. STW Schemes at Kashimpur Mouza of Hemtabad Block under the jurisdiction of Raiganj (A-I) Division under RIDF-XX programme. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | MATERIALS FOR LT LINE : ( PLOT NO. 124 ) | BI01010001010000000000000515BI0100001112 | ||
| 2 | 1.01 | PCC Pole 8m long | 1 | No. | |
| 3 | 1.02 | MS Flat 50 X 6 mm | 0.005 | MT | |
| 4 | 1.03 | MS Angle 50 X 50 X 6 mm | 0.015 | MT | |
| 5 | 1.04 | Stay set complete(LT) | 2 | Set | |
| 6 | 1.05 | Guy Insulator(LT) | 3 | No. | |
| 7 | 1.06 | Stay Wire 7/2.5mm (7 / 12) | 0.015 | MT | |
| 8 | 1.07 | GI Wire 5MM (6 SWG) | 0.005 | MT | |
| 9 | 1.08 | Earth Spike | 2 | Nos | |
| 10 | 1.09 | PVC Cable 4C (10 Sq. mm) | 0.036 | Km | |
| 11 | 1.1 | D Iron Clamp 75X90mm | 5 | No. | |
| 12 | 1.11 | Shackle Insulator 3\"x3.5\" | 5 | Nos. | |
| 13 | 1.12 | Sundries @ 5 % on sum of 1.01 to 1.11 | 1 | Nos. | |
| 14 | 2 | MATERIALS FOR HT LINE : ( PLOT NO. 124 ) | |||
| 15 | 2.01 | PCC Pole 8 m 8 m | 3 | No. | |
| 16 | 2.02 | MS Channel 75 X 40 X 6 mm | 0.045 | MT | |
| 17 | 2.03 | MS Angle 65 X 65 X 6 mm | 0.036 | MT | |
| 18 | 2.04 | MS Flat 65 X 6 mm | 0.052 | MT | |
| 19 | 2.05 | Pin Insulator 11 Kv | 6 | No. | |
| 20 | 2.06 | GI Pin for above 11 Kv | 6 | No. | |
| 21 | 2.07 | Disc Insulator 45 KN | 9 | No. | |
| 22 | 2.08 | Hardware Fittings 50 Sq. mm | 9 | Set | |
| 23 | 2.09 | Stay Set HT 1830 X 20 mm | 5 | Set | |
| 24 | 2.1 | Guy Insulator Set | 5 | No. | |
| 25 | 2.11 | Stay Wire 7 / 10 SWG 7 / 3.15 mm | 0.03 | MT | |
| 26 | 2.12 | GI Earth Spike 1822 X 20 mm | 4 | No. | |
| 27 | 2.13 | GI Wire SWG 6 SWG 5.00 mm | 0.012 | MT | |
| 28 | 2.14 | ACSR Conductor 30 Sq. mm | 0.52 | km | |
| 29 | 2.15 | Caution Board 11 kv | 2 | No. | |
| 30 | 2.16 | V Bracket 11 kv | 1 | No. | |
| 31 | 2.17 | Top Adaptor 11 kv | 1 | No. | |
| 32 | 2.18 | Barbed wire MT | 0.006 | No. | |
| 33 | 2.19 | Sundries @ 5 % on sum of 2.01 to 2.18 | 1 | No. | |
| 34 | 3 | MATERIALS FOR DTR : ( PLOT NO. 124 ) | |||
| 35 | 3.01 | PCC Pole 9 m | 2 | No. | |
| 36 | 3.02 | MS Channel 100 X 50 X 6 mm | 0.005 | MT | |
| 37 | 3.03 | MS Channel 75 X 40 X 6 mm | 0.21 | MT | |
| 38 | 3.04 | MS Angle 65 X 65 X 6 mm | 0.133 | MT | |
| 39 | 3.05 | MS Flat 65 X 6 mm | 0.108 | MT | |
| 40 | 3.06 | Pin Insulator 11 Kv | 16 | No. | |
| 41 | 3.07 | Pin for above 11 Kv | 15 | No. | |
| 42 | 3.08 | Disc Insulator 45 KN | 7 | No. | |
| 43 | 3.09 | Hardware Fittings 50 Sq. mm | 6 | Set | |
| 44 | 3.1 | Stay Set HT 1830 X 20 mm | 4 | Set | |
| 45 | 3.11 | Guy Insulator HT Set | 4 | No. | |
| 46 | 3.12 | Stay Wire 7 / 10 SWG 7 / 3.15 mm | 0.024 | MT | |
| 47 | 3.13 | GI Earth Spike 1822 X 20 mm | 6 | No. | |
| 48 | 3.14 | GI Wire 6 SWG 5.00 mm | 0.024 | MT | |
| 49 | 3.15 | ACSR Conductor | 0.03 | MT | |
| 50 | 3.16 | TPGO Isolator 11 Kv | 1 | Set | |
| 51 | 3.17 | DTR ( 11 X 0.433 Kv ) | 1 | No. | |
| 52 | 3.18 | 300 Amp porcelain fuse | 6 | No. | |
| 53 | 3.19 | PVC Cable 4 Core 1.1 Kv | 0.032 | km | |
| 54 | 3.2 | Caution Board 11 kV | 1 | No. | |
| 55 | 3.21 | Turn Buckle | 2 | No. | |
| 56 | 3.22 | Lighting Arrestor 12 Kv | 1 | Set | |
| 57 | 3.23 | Supply and fixing of GI 50 mm dia. Perforated pipe earthing for DTE LA HT | 1 | No. | |
| 58 | 3.24 | Kiosk Box LT | 1 | No. | |
| 59 | 3.25 | D Iron Clamp LT | 8 | No. | |
| 60 | 3.26 | Shackle Insulator LT | 8 | No. | |
| 61 | 3.27 | Sundries @ 5 % on sum of 3.01 to 3.27 | 1 | No. | |
| 62 | 4 | LABOUR CHARGES FOR LT LINE : ( PLOT NO. 124 ) | |||
| 63 | 4.01 | Erection of 8 m long PCC pole without fittings | 1 | No. | |
| 64 | 4.02 | Erection of LT stay set complete | 2 | Set | |
| 65 | 4.03 | Earthing Complete | 2 | No. | |
| 66 | 4.04 | Stringing and sagging of 4 core 6/10/16 sq.mm. PVC Cable inplace of ACSR 20 Sq.mm. | 0.03 | Km | |
| 67 | 4.05 | Stringing and sagging of 4 -5 mm GI 1 WIRE | 0.03 | Km | |
| 68 | 4.06 | Fixing LT Shackle insulator | 5 | No. | |
| 69 | 4.07 | Fixing of Angle Bracket on Meter room + LT Bracket on pole | 1 | No. | |
| 70 | 4.08 | Fixing of 3 phase meter | 1 | No. | |
| 71 | 4.09 | Binding of Stay wire between meter angle and any other fixer | 1 | No. | |
| 72 | 4.1 | Fixing of LT Bracket | 1 | No. | |
| 73 | 5 | LABOUR CHARGES FOR HT LINE : ( PLOT NO. 124 ) | |||
| 74 | 5.01 | Errection of 8 mt. PCC DP | 1 | unit | |
| 75 | 5.02 | Erection of 8 mt. PCC Pole SP with fittings, HT | 1 | unit | |
| 76 | 5.03 | Stringing and sagging of 30 sq.mm. , 3 wire conductor | 0.167 | unit | |
| 77 | 5.04 | Fixing of Insulator 11KV PIN INSULATOR with GI Pin | 6 | unit | |
| 78 | 5.05 | Fixing of Insulator 45KN DISC. INSULATOR with hardwire fittings.(for 30&50 sq.mm. conductor.) | 9 | unit | |
| 79 | 5.06 | Erection of Stay HT | 5 | unit | |
| 80 | 5.07 | Fixing of Earthing | 4 | unit | |
| 81 | 5.08 | Fixing of Tee - Off Bracket in single pole(with paint) | 1 | unit | |
| 82 | 5.09 | Fixing of anti-climbing device | 3 | unit | |
| 83 | 5.1 | Survey for HT -OH Line | 0.167 | unit | |
| 84 | 5.11 | Fixing of caution board | 2 | unit | |
| 85 | 6 | LABOUR CHARGES FOR DTR : ( PLOT NO. 124 ) | |||
| 86 | 6.01 | Erection of S / Stn. Struc. ( Paint ) 9 m | 1 | unit | |
| 87 | 6.02 | Fixing of TA / VB in SP | 4 | unit | |
| 88 | 6.03 | Fixing of Pin Insulator 11 Kv | 15 | unit | |
| 89 | 6.04 | Erection of Stay HT | 4 | unit | |
| 90 | 6.05 | Erection of Earthing | 6 | unit | |
| 91 | 6.06 | Fixing of Isolator ( 11 Kv TPGO ) | 1 | unit | |
| 92 | 6.07 | Erection of DTR ( 63 Kva ) ( 11 / 0.433 ) | 1 | unit | |
| 93 | 6.08 | Fixing of Caution Board | 1 | unit | |
| 94 | 6.09 | Fixing of 11 Kv Disc Isolator | 6 | unit | |
| 95 | 6.1 | Extn. Of PCC Pole upto 3 m paint | 2 | unit | |
| 96 | 6.11 | Fixing of Shackle Insulator | 8 | unit | |
| 97 | 6.12 | Fixing of Kiosk Box and Cut-out ( Paint ) | 1 | unit | |
| 98 | 6.13 | Fixing of C Out ( Double CKT ) with Cable Connection | 1 | unit | |
| 99 | 6.14 | Fixing of Box Bracket ( Paint ) | 2 | unit | |
| 100 | 6.15 | Fixing of LA ( Set ) | 1 | unit | |
| 101 | 6.16 | Labour for LA Earthing | 1 | unit | |
| 102 | 7 | MATERIALS FOR LT LINE : ( PLOT NO. 1552 ) | |||
| 103 | 7.01 | PCC Pole 8m long | 7 | No. | |
| 104 | 7.02 | MS Flat 50 X 6 mm | 0.05 | MT | |
| 105 | 7.03 | MS Angle 50 X 50 X 6 mm | 0.01 | MT | |
| 106 | 7.04 | Stay set complete(LT) | 4 | Set | |
| 107 | 7.05 | Guy Insulator(LT) | 5 | No. | |
| 108 | 7.06 | Stay Wire 7/2.5mm (7 / 12) | 0.025 | MT | |
| 109 | 7.07 | GI Wire 5MM (6 SWG) | 0.024 | MT | |
| 110 | 7.08 | Earth Spike | 8 | Nos | |
| 111 | 7.09 | PVC Cable 4C (10 Sq. mm) | 0.855 | Km | |
| 112 | 7.1 | D Iron Clamp 75X90mm | 22 | No. | |
| 113 | 7.11 | Shackle Insulator 3\"x3.5\" | 22 | Nos. | |
| 114 | 7.12 | ACSR 30 Sq. mm | 0.01 | km | |
| 115 | 7.13 | GI WIRE 4 mm (8SWG) | 0.096 | MT | |
| 116 | 7.14 | Sundries @ 5 % on sum of 7.01 to 7.13 | 1 | Nos | |
| 117 | 8 | LABOUR CHARGES FOR LT LINE : ( PLOT NO. 1552 ) | |||
| 118 | 8.01 | Survey (pre& final) for L&MV OH Line | 0.274 | Km | |
| 119 | 8.02 | Erection of 8 m long PCC pole without fittings | 7 | No. | |
| 120 | 8.03 | Erection of LT stay set complete | 4 | Set | |
| 121 | 8.04 | Earthing Complete | 8 | No. | |
| 122 | 8.05 | Stringing and sagging of 4 core 6/10/16 sq.mm. PVC Cable inplace of ACSR 20 Sq.mm. | 0.88 | Km | |
| 123 | 8.06 | Stringing and sagging of 4 -5 mm GI 1 WIRE | 0.88 | Km | |
| 124 | 8.07 | Fixing of pole clamp | 21 | PAA | |
| 125 | 8.08 | Fixing LT Shackle insulator | 22 | No. | |
| 126 | 8.09 | Fixing of Angle Bracket on Meter room | 1 | No. | |
| 127 | 8.1 | Binding of Stay wire between meter angle and any other fixer | 1 | No. | |
| 128 | 8.11 | Inspection Charge | 1 | No. | |
| 129 | 8.12 | Fixing of 3 phase meter | 1 | No. | |
| 130 | 9 | MATERIALS FOR LT LINE : ( PLOT NO. 48 ) | |||
| 131 | 9.01 | PCC Pole 8m long | 4 | No. | |
| 132 | 9.02 | MS Flat 50 X 6 mm | 0.036 | MT | |
| 133 | 9.03 | MS Angle 50 X 50 X 6 mm | 0.01 | MT | |
| 134 | 9.04 | Stay set complete(LT) | 4 | Set | |
| 135 | 9.05 | Guy Insulator(LT) | 5 | No. | |
| 136 | 9.06 | Stay Wire 7/2.5mm (7 / 12) | 0.025 | MT | |
| 137 | 9.07 | GI Wire 5MM (6 SWG) | 0.015 | MT | |
| 138 | 9.08 | Earth Spike | 5 | Nos | |
| 139 | 9.09 | PVC Cable 4C (10 Sq. mm) | 0.65 | Km | |
| 140 | 9.1 | D Iron Clamp 75X90mm | 16 | No. | |
| 141 | 9.11 | Shackle Insulator 3\"x3.5\" | 16 | Nos. | |
| 142 | 9.12 | ACSR 30 Sq. mm | 0.01 | km | |
| 143 | 9.13 | GI WIRE 4 mm (8SWG) | 0.096 | MT | |
| 144 | 9.14 | Sundries @ 5 % on sum of 9.01 to 9.13 | 1 | No. | |
| 145 | 10 | LABOUR CHARGES FOR LT LINE : ( PLOT NO. 48 ) | |||
| 146 | 10.01 | Survey (pre& final) for L&MV OH Line | 0.168 | Km | |
| 147 | 10.02 | Erection of 8 m long PCC pole without fittings | 4 | No. | |
| 148 | 10.03 | Erection of LT stay set complete | 4 | Set | |
| 149 | 10.04 | Earthing Complete | 5 | No. | |
| 150 | 10.05 | Stringing and sagging of 4 core 6/10/16 sq.mm. PVC Cable inplace of ACSR 20 Sq.mm. | 0.648 | Km | |
| 151 | 10.06 | Stringing and sagging of 4 -5 mm GI 1 WIRE | 0.648 | Km | |
| 152 | 10.07 | Fixing of pole clamp | 15 | PAA | |
| 153 | 10.08 | Fixing LT Shackle insulator | 16 | No. | |
| 154 | 10.09 | Fixing of Angle Bracket on Meter room | 1 | No. | |
| 155 | 10.1 | Binding of Stay wire between meter angle and any other fixer | 1 | No. | |
| 156 | 10.11 | Inspection Charge | 1 | No. | |
| 157 | 10.12 | Fixing of 3 phase meter | 1 | No. | |
| 158 | 11 | MATERIALS FOR LT LINE : ( PLOT NO. 101 ) | |||
| 159 | 11.01 | PCC Pole 8m long | 9 | No. | |
| 160 | 11.02 | MS Flat 50 X 6 mm | 0.036 | MT | |
| 161 | 11.03 | MS Angle 50 X 50 X 6 mm | 0.015 | MT | |
| 162 | 11.04 | Stay set complete(LT) | 4 | Set | |
| 163 | 11.05 | Guy Insulator(LT) | 5 | No. | |
| 164 | 11.06 | Stay Wire 7/2.5mm (7 / 12) | 0.025 | MT | |
| 165 | 11.07 | GI Wire 5MM (6 SWG) | 0.03 | MT | |
| 166 | 11.08 | Earth Spike | 10 | Nos | |
| 167 | 11.09 | PVC Cable 4C (10 Sq. mm) | 0.626 | Km | |
| 168 | 11.1 | D Iron Clamp 75X90mm | 16 | No. | |
| 169 | 11.11 | Shackle Insulator 3\"x3.5\" | 16 | Nos. | |
| 170 | 11.12 | ACSR 30 Sq. mm | 0.015 | km | |
| 171 | 11.13 | GI WIRE 4 mm (8SWG) | 0.09 | MT | |
| 172 | 11.14 | Sundries @ 5 % on sum of 11.01 to 11.13 | 1 | No. | |
| 173 | 12 | LABOUR CHARGES FOR LT LINE : ( PLOT NO. 101 ) | |||
| 174 | 12.01 | Survey (pre& final) for L&MV OH Line | 0.35 | Km | |
| 175 | 12.02 | Erection of 8 m long PCC pole without fittings | 9 | No. | |
| 176 | 12.03 | Erection of LT stay set complete | 4 | Set | |
| 177 | 12.04 | Earthing Complete | 10 | No. | |
| 178 | 12.05 | Stringing and sagging of 4 core 6/10/16 sq.mm. PVC Cable inplace of ACSR 20 Sq.mm. | 0.62 | Km | |
| 179 | 12.06 | Stringing and sagging of 4 -5 mm GI 1 WIRE | 0.62 | Km | |
| 180 | 12.07 | Fixing of pole clamp | 15 | PAA | |
| 181 | 12.08 | Fixing LT Shackle insulator | 16 | No. | |
| 182 | 12.09 | Fixing of Angle Bracket on Meter room | 1 | No. | |
| 183 | 12.1 | Binding of Stay wire between meter angle and any other fixer | 1 | No. | |
| 184 | 12.11 | Inspection Charge | 1 | No. | |
| 185 | 12.12 | Fixing of 3 phase meter | 1 | No. | |
| 186 | 13 | MATERIALS FOR LT LINE : ( PLOT NO. 86 / 133 ) | |||
| 187 | 13.01 | PCC Pole 8m long | 11 | No. | |
| 188 | 13.02 | MS Flat 50 X 6 mm | 0.029 | MT | |
| 189 | 13.03 | MS Angle 50 X 50 X 6 mm | 0.015 | MT | |
| 190 | 13.04 | Stay set complete(LT) | 6 | Set | |
| 191 | 13.05 | Guy Insulator(LT) | 7 | No. | |
| 192 | 13.06 | Stay Wire 7/2.5mm (7 / 12) | 0.035 | MT | |
| 193 | 13.07 | GI Wire 5MM (6 SWG) | 0.036 | MT | |
| 194 | 13.08 | Earth Spike | 12 | Nos | |
| 195 | 13.09 | PVC Cable 4C (10 Sq. mm) | 0.416 | Km | |
| 196 | 13.1 | D Iron Clamp 75X90mm | 15 | No. | |
| 197 | 13.11 | Shackle Insulator 3\"x3.5\" | 15 | Nos. | |
| 198 | 13.12 | ACSR 30 Sq. mm | 0.01 | km | |
| 199 | 13.13 | GI WIRE 4 mm (8SWG) | 0.059 | MT | |
| 200 | 13.14 | Sundries @ 5 % on sum of 13.01 to 13.13 | 1 | No. | |
| 201 | 14 | LABOUR CHARGES FOR LT LINE : ( PLOT NO. 86 / 133 ) | |||
| 202 | 14.01 | Survey (pre& final) for L&MV OH Line | 0.38 | Km | |
| 203 | 14.02 | Erection of 8 m long PCC pole without fittings | 11 | No. | |
| 204 | 14.03 | Erection of LT stay set complete | 6 | Set | |
| 205 | 14.04 | Earthing Complete | 12 | No. | |
| 206 | 14.05 | Stringing and sagging of 4 core 6/10/16 sq.mm. PVC Cable inplace of ACSR 20 Sq.mm. | 0.41 | Km | |
| 207 | 14.06 | Stringing and sagging of 4 -5 mm GI 1 WIRE | 0.41 | Km | |
| 208 | 14.07 | Fixing of pole clamp | 10 | PAA | |
| 209 | 14.08 | Fixing LT Shackle insulator | 15 | No. | |
| 210 | 14.09 | Fixing of Angle Bracket on Meter room | 1 | No. | |
| 211 | 14.1 | Binding of Stay wire between meter angle and any other fixer | 1 | No. | |
| 212 | 14.11 | Inspection Charge | 1 | No. | |
| 213 | 14.12 | Fixing of 3 phase meter | 1 | No. | |
| 214 | 14.13 | Fixing of LT Bracket | 1 | Km | |
| 215 | 15 | MATERIALS FOR LT LINE : ( PLOT NO. 319 ) | |||
| 216 | 15.01 | PCC Pole 8m long | 3 | No. | |
| 217 | 15.02 | MS Flat 50 X 6 mm | 0.008 | MT | |
| 218 | 15.03 | MS Angle 50 X 50 X 6 mm | 0.01 | MT | |
| 219 | 15.04 | Stay set complete(LT) | 2 | Set | |
| 220 | 15.05 | Guy Insulator(LT) | 3 | No. | |
| 221 | 15.06 | Stay Wire 7/2.5mm (7 / 12) | 0.015 | MT | |
| 222 | 15.07 | GI Wire 5MM (6 SWG) | 0.012 | MT | |
| 223 | 15.08 | Earth Spike | 4 | Nos | |
| 224 | 15.09 | PVC Cable 4C (10 Sq. mm) | 0.155 | Km | |
| 225 | 15.1 | D Iron Clamp 75X90mm | 4 | No. | |
| 226 | 15.11 | Shackle Insulator 3\"x3.5\" | 4 | Nos. | |
| 227 | 15.12 | ACSR 30 Sq. mm | 0.005 | km | |
| 228 | 15.13 | GI WIRE 4 mm (8SWG) | 0.022 | MT | |
| 229 | 15.14 | Sundries @ 5 % on sum of 15.01 to 15.13 | 1 | No. | |
| 230 | 16 | LABOUR CHARGES FOR LT LINE : ( PLOT NO. 319 ) | |||
| 231 | 16.01 | Survey (pre& final) for L&MV OH Line | 0.12 | Km | |
| 232 | 16.02 | Erection of 8 m long PCC pole without fittings | 3 | No. | |
| 233 | 16.03 | Erection of LT stay set complete | 2 | Set | |
| 234 | 16.04 | Earthing Complete | 4 | No. | |
| 235 | 16.05 | Stringing and sagging of 4 core 6/10/16 sq.mm. PVC Cable inplace of ACSR 20 Sq.mm. | 0.15 | Km | |
| 236 | 16.06 | Stringing and sagging of 4 -5 mm GI 1 WIRE | 0.15 | Km | |
| 237 | 16.07 | Fixing of pole clamp | 3 | PAA | |
| 238 | 16.08 | Fixing LT Shackle insulator | 4 | No. | |
| 239 | 16.09 | Fixing of Angle Bracket on Meter room | 1 | No. | |
| 240 | 16.1 | Binding of Stay wire between meter angle and any other fixer | 1 | No. | |
| 241 | 16.11 | Inspection Charge | 1 | No. | |
| 242 | 16.12 | Fixing of 3 phase meter | 1 | No. | |
| 243 | 17 | Supervision charges @15 % on sum of 1.01 to 16.12 | 1 | No. | |
| 244 | 18 | Cess @1 % on sum of 1.01 to 16.12 | 1 | No. |
AI Tender Summary
Tender Timeline
Feb 05, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 20, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 22, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender