| 1 | 1 | SH-I :- Operation and Maintenance of E & M installations of NITB.\nOperation and Preventive Maintenance of Electrical / Mechanical Installations at NITB and associated ancillary buildings by attending complaints / faults / breakdown & ensuring serviceability, satisfactory working condition of all the systems, up keeping all records as per preventive maintenance schedule etc. by providing the adequate & suitable man power with tools & tackles in shifts as mentioned in the special conditions of contract complete as required on all days including sundays & holidays. | | 24 | Month |
|---|
| 2 | 2.1 | Provision of additional hour required for operations due to delay in flight, emergency, major maintenance works. Beyond the scope of item no. 1 on daily basis.\nHi-Skilled | | 100 | Hour |
|---|
| 3 | 2.2 | Skilled | | 100 | Hour |
|---|
| 4 | 2.3 | Un-skilled | | 100 | Hour |
|---|
| 5 | 3.1 | Rewinding of following Motors with original no.of turn and wire gauge i/c repairing of bush, replacement of bearing, termination of connecting lead, connection, testing & commissioning complete as required. (Dismantled copper wire need not to return).\na) 0.5 to 2HP Motor | | 10 | Each |
|---|
| 6 | 3.2 | b) 3 HP Motor | | 2 | Each |
|---|
| 7 | 3.3 | c) 7.5 HP Motor | | 4 | Each |
|---|
| 8 | 3.4 | d) 10HP Motor | | 4 | Each |
|---|
| 9 | 4 | Execution / carryout the work for items covered / listed in CPWD Scheduled of rates (Electrical)-2018 published by CPWD as per CPWD specifications for an amount of Rs.3,00,000/- [Excluding GST] as required. \n(Agency has to execute schedule item listed in CPWD S/R(Electrical) 2018 as and when required by AAI. May please refer NIT clause 23 (e) (ii), page no.NIT -4&5 for quoting of rate for this item no.4) | | 1 | Job |
|---|
| 10 | 5 | SH-II :- Operation and Maintenance of Water supply Pumps\nOperation of different type of water supply pumps, drainage pumps, mutigrade media filters, activated carbon filters, softeners, RO plant etc. including Backwash, Rinse & Clean-in-place (CIP) of the same as required with deployment of minimum manpower as per special conditions of contract. | | 24 | Month |
|---|
| 11 | 6 | Descaling of RO Plant with recommended chemical / desclaing treatment by using Acidic cleaner and Antiscalant of reputed make as approved by Engineer-in-charge and as per the recommendation of OEM.. | | 8 | Job |
|---|
| 12 | 7 | Regular Antiscalant dosing by TITAN ASD or equivelent Antiscalant to maintain performance of RO Plant as per OEM recommendation (0.3Kg x 31 day )= 10kg/month x 02 year | | 240 | Kg |
|---|
| 13 | 8 | Recharging (Regenerate) of softener by ion exchange method (minimum 250 KG common salt/ non iodised salt) including preparation of brine solution as and when required. | | 96 | Job |
|---|
| 14 | 9 | Supply & mixing of liquid Sodium Hypochlorite in water as and when required. | | 50 | Kg |
|---|
| 15 | 10 | Taking samples of drinking water from different locations and submit report of potability test from Govt. laboratory / Govt. Approved laboratory . | | 96 | Job |
|---|
| 16 | 11 | Supply of 20\" Spun Filter suitable for 1150 LPH RO plant installed at Vadodara Airport | | 24 | Each |
|---|
| 17 | 12 | Supply of 10\", 5 Micron, Pre Filter for RO outlet point at provided in NITB. | | 96 | Each |
|---|
| 18 | 13 | Supply of 8.5\", 900IV carbon Filter for RO outlet point at provided in NITB. | | 24 | Each |
|---|
| 19 | 14 | Supply of 40'' membrane for RO Plant (Make- Matrix /DOW/Permionics ) | | 4 | Each |
|---|
| 20 | 15 | SH:III:- AMC of Fire Alarm & Fire Fighting system \nOperation and preventive maintenance contract of Fire Alarm system, Fire hydrant system,Fire alarm with auto dialar system ,Sprinkler system and Aspiration system at different locations as detailed given below in three shifts involving attending to complaints/ faults/ breakdowns and taking rectification action with deployment of minimum man power as per special condition of contract, ensuring serviceability / satisfactory working conditions of the system and maintain records / documentation etc. Half yearly Inspection of the fire alarm and Aspiration system by OEM/ Authorised service dealer of OEM with submission of reports as per the detailed specifications, terms & conditions covered under this contract on all days including sunday and holidays. \na) For New Terminal Building :-Addressable fire alarm & fire hydrant system, Sprinkler system & Aspiration system\nb) For Old Terminal building :-Conventional fire alarm system & Fire hydrant system\nc) For ATC cum Technical block :-Conventional fire alarm system & Fire hydrant system\nd) For NAV-AIDS :-Fire alarm and auto dialer system.\n(Note :- This item does not include supply of spares, overhaluling/ servicing of diesel engine,rewinding of motors and repairing of pumps.) | | 24 | Month |
|---|
| 21 | 16 | Supply of addressable Photoelectric Smoke Detector (Make :Honeywell, Part no. 851 ) | | 10 | Each |
|---|
| 22 | 17 | Supply of addressable Control Module etc. for Directional Sounder, Sounder with Flasher etc complete as required.(Make : Notifire, Model FCM-1) | | 5 | Each |
|---|
| 23 | 18 | Supply of addressable Relay Module etc. for AHU, Fire dampars , Smoke ventilation etc complete as required.(Make : Notifire, Model FRM-1) | | 5 | Each |
|---|
| 24 | 19 | Supply of Addressable type manual call (Glass Break) Station complete with all accessories. (Make : Notifire, Model -F/MCC/GLASS-1) | | 5 | Each |
|---|
| 25 | 20 | Supply of Addressable type Monitor module to take signal from thirdparty device to fire panel can detect with all accessories. (Make : Notifire, Model FMM-1) | | 5 | Each |
|---|
| 26 | 21 | Painting, of fire alarm and fire fighting system installation, RO Plant installation including associated internal and exposed pipe lines, Motors, Pumps, associated valves, fittings and supports of all associated installations at service block, trench and NITB area with two coats of anti-rust paint etc.complete as per site requirement [ Approximate 300 sqmtr in 01 Job] | | 2 | Job |
|---|
| 27 | 22 | SH:IV:- Operation of Departure conveyor system (01 set) and Arrival carousals conveyor system (03 sets) \nOperation and preventive maintenance of Departure conveyor system (01 set) and Arrival carousals conveyor system (03 sets) in two shifts as by deploying adequate & suitable man power with tools & tackles in shifts as mentioned in the special conditions of contract complete as required on all days including sundays & holidays.\n | | 24 | Month |
|---|
| 28 | 23.1 | SH:V:- Supply of Electrical spares.\nSupply of following sizes (Nominal cross sectional area based on CR Value as per IS) FRLS insulated Stranded copper conductor, wiring cable of approved make and different colour (90 Mtr length of each Roll)\na) Single core,1.5Sqmm Wire | | 8 | Coil |
|---|
| 29 | 23.2 | b) Single core,2.5Sqmm Wire | | 6 | Coil |
|---|
| 30 | 23.3 | c) Single core,4Sqmm Wire | | 8 | Coil |
|---|
| 31 | 23.4 | d) Single core,6Sqmm Wire | | 4 | Coil |
|---|
| 32 | 24.1 | Supply of following Size Three Core Unsheathed Industrial Flexible FRLS Stranded copper conductor,insulated cable conforming IS 694:1990 with Flexible bright Annealed Copper conductor, for Voltage Grade upto 1100V.(Make - AAI approved make list) and (100 Mtr length of each Roll).\na) 3 core x 1.5 Sqmm | | 4 | Coil |
|---|
| 33 | 24.2 | b) 3 core x 2.5 Sqmm | | 2 | Coil |
|---|
| 34 | 24.3 | c) 3 core x 4 sqmm | | 4 | Coil |
|---|
| 35 | 25.01 | Supply of following types of Ballast, LED Driver & LED lamp as complete as per site requirement. (Make: AAI approved make)\nElectronic Ballast :-\na) 36W,Electronics ballast (Make : Philips, EB-T136TLD) | | 25 | Each |
|---|
| 36 | 25.02 | b) 1 x 54W,T5 Electronics ballast (Make : Philips) | | 50 | Each |
|---|
| 37 | 25.03 | LED Drivers:-\na) LED Strip Driver, 2A,12V,24W Output,220-240 Input,(Make: Philips, Model:LSD2A) | | 50 | Each |
|---|
| 38 | 25.04 | b) LED strip Driver, 5A,12V,24W Output,220-240 Input. | | 50 | Each |
|---|
| 39 | 25.05 | c) LED Driver, 24W,AC 180V to 280V, (Make: Osram, Model no.OTi DALI 50/220-240/24) | | 20 | Each |
|---|
| 40 | 25.06 | d) LED Driver 0.70A,16/26W for 25W LED Fitting (Make: Philips, Part no.25W/700mA) | | 100 | Each |
|---|
| 41 | 25.07 | e) LED Driver,160W for 300W LED Flood light fitting (Make: Bajaj, Model no.BRFLED 160W) | | 10 | Each |
|---|
| 42 | 25.08 | Lamps:-\na) 9W LED Lamp (Make: As per list of approved make of tender) | | 100 | Each |
|---|
| 43 | 25.09 | b) 150W MHN -TD Lamp (Make: As per list of approved make of tender) | | 70 | Each |
|---|
| 44 | 25.1 | c) GLS ,40W Threaded type (Make: As per list of approved make of tender) | | 100 | Each |
|---|
| 45 | 25.11 | d) 54W T5 Lamp (Make: As per list of approved make of tender) | | 50 | Each |
|---|
| 46 | 25.12 | e) LED Strip (Make: As per list of approved make of tender) | | 100 | Mtr |
|---|
| 47 | 25.13 | f) 1000W Halogen lamp (Make: As per list of approved make of tender) | | 100 | Each |
|---|
| 48 | 25.14 | g) 50W spot type halogen lamp (Make: Philips/ as per list of approved make of tender) | | 10 | Each |
|---|
| 49 | 26.1 | Supply of following type of MCCB (In Accordance with IS/IEC 60898-1) 240/415V, 50Hz, Suitable for motor & other Inductive loads etc. as required. \na) 630A,4P,50KA MCCB, 'C' Series, (DN3-630N) \n(Make: L&T, Cat no.CM94104OOT1OG ) | | 1 | Each |
|---|
| 50 | 26.2 | b) 400A,4P,50KA MCCB, 'C' Series, (DN3-400N) \n(Make: L&T, Cat no.CM94103OOr1OG ) | | 1 | Each |
|---|
| 51 | 26.3 | c) 250A,4P,36KA MCCB, 'C' Series, (DN2-250D) \n(Make: L&T, Cat no.CM92109OOP1OG ) | | 1 | Each |
|---|
| 52 | 26.4 | d) 160A,4P,36KA MCCB, 'C' Series, (DN2-250D)\n(Make: L&T, Cat no.CM92109OON1OG ) | | 1 | Each |
|---|
| 53 | 26.5 | e) 125A,4P,36KA MCCB, 'C' Series, (DN2-250D)\n(Make: L&T, Cat no.CM92108OOM1OG ) | | 1 | Each |
|---|
| 54 | 27.1 | Supply of following type of RCCB (In Accordance with IS12640-1 & IEC 61008-1) 240/415V,50Hz,10KA short circuit withstand capacity as required.\na) 63A,4P,300 mA RCCB (Make : Legrand) | | 40 | Each |
|---|
| 55 | 28.01 | Supply of Piano / modular type Switch / Socket / Plug Top of following type and rating suitable to operate on 240V,50Hz AC Supply (as per list of approved make of tender)\na) 6A,3pin,240V, Piano type Socket | | 100 | Each |
|---|
| 56 | 28.02 | b) 16A,5pin,240V,Piano type Socket | | 100 | Each |
|---|
| 57 | 28.03 | c) 15/16A,1way,240V Piano type Switch | | 100 | Each |
|---|
| 58 | 28.04 | d) 5/6A,1way,240V Piano type Switch | | 200 | Each |
|---|
| 59 | 28.05 | e) 10A,240V,Modular Switch | | 50 | Each |
|---|
| 60 | 28.06 | f) 20A,240V,Modular Switch | | 30 | Each |
|---|
| 61 | 28.07 | g) 15A,240V, Plug Top | | 75 | Each |
|---|
| 62 | 28.08 | h) 32A-6H/380-415V, 3P+N+E, 50Hz industrial socket with box | | 10 | Each |
|---|
| 63 | 28.09 | I) Supply of Ding dong bell | | 25 | Each |
|---|
| 64 | 28.1 | J) Supply of Remote bell | | 25 | Each |
|---|
| 65 | 29.1 | Supply of Following type Capacitor / Condenser for ceiling fan / exhaust fan, APFC Panel suitable for 240V,50Hz AC supply (Make-Epcos, Neptune)\na) 2.5 MFD for Ceiling Fan Capacitor | | 200 | Each |
|---|
| 66 | 29.2 | b) 5KVAR,415Volt,50Hz, Super Heavy Duty Cylinder Type capacitor | | 5 | Each |
|---|
| 67 | 29.3 | c) 10KVAR,415Volt,50Hz, Super Heavy Duty Cylinder Type capacitor | | 10 | Each |
|---|
| 68 | 30.1 | Supply of following size PVC casing capping as reqd. (Precision / AKG / AAI approved make)\na) Casing caping 25mm | | 120 | Mtr |
|---|
| 69 | 30.2 | b) Casing caping 20mm | | 200 | Mtr |
|---|
| 70 | 31 | Supply of 22.5 mm size flush mounted type LED indicators suitable for 240V,50Hz AC Supply .(Make:- AAI approved make List). | | 150 | Each |
|---|
| 71 | 32 | Supply of 4W,220-440Volt,50Hz Emergency Light(Make:-Philips / as per list of approved make of tender) | | 15 | Each |
|---|
| 72 | 33 | Supply of PVC Extention Board with 4way socket with individual switch (Make:Anchor/ or similar of Legrand / L&T/ Havells) | | 10 | Each |
|---|
| 73 | 34 | Supply of fuses (As per list of approved make of tender)\na) 100A,80KA,415V,Bolt type,HRC Fuse Links | | 2 | Each |
|---|
| 74 | 35.1 | Supply of following contactor\na) ML-3, 415V,50Hz Power Contactor (Make: L&T) | | 2 | Each |
|---|
| 75 | 35.2 | b) ML-4 , 415V,50Hz Power Contactor (Make: L&T) | | 2 | Each |
|---|
| 76 | 36 | 9W Aviation obstruction light Single dome (Make: Bajaj,Model no.BGAV 302 / as per list of approved make of tender) | | 5 | Each |
|---|
| 77 | 37 | Supply of 22W LED, 4 Feet, aluminium base batten Tube light fitting,suitable for operation on 230V, 50Hz, single phase AC Supply (Make: Philips / Bajaj/ Crompton / Halonix ) | | 60 | Each |
|---|
| 78 | 38 | Supply of Float switch sensor for vertical submersible pump | | 20 | Each |
|---|
| 79 | 39 | Supply of 6A Auto manual selector switch (AC23A,440V,3KW-3.8A) (Make : L&T) | | 20 | Each |
|---|
| 80 | 40 | Supply of 32A/660V AC/DC, Trip & close type TNC Control switch (Make: L&T ) | | 10 | Each |
|---|
| 81 | 41 | 360 degree, Surface mount, PIR sensor for auto control of light (Make :- MK Honeywell, Model- K5016 ) | | 15 | Each |
|---|
| 82 | 42 | Supply of 16A. 6 Pin male & Female connector for BAJAJ make high mast tower. | | 6 | Each |
|---|
| 83 | 43 | Supply of Glass for BARFEG 300W (Make: Bajaj) LED Fitting. | | 5 | Each |
|---|
| 84 | 44 | Supply of LED Chip, LED MCPCB 350 x 230MM (96 LED) for Bajaj make, Model:,BARFEG 300W LED) 300W LED Fitting | | 5 | Each |
|---|