Repair To Point Wiring And Connected Works At Dgrr In Rpso Complex And Repair/Maintenance Of Summer Appliances And Connected Items In The Area Of Age E/M Under Ge East Delhi Cantt-10 ( Ge/De-74/2020-21 ) Repair To Point Wiring And Connected Works At Dg, GE (East) Delhi Cantt-10-Delhi

Military Engineer Services-MES has published Repair To Point Wiring And Connected Works At Dgrr In Rpso Complex And Repair/Maintenance Of Summer Appliances And Connected Items In The Area Of Age E/M Under Ge East Delhi Cantt-10 ( Ge/De-74/2020-21 ) Repair To Point Wiring And Connected Works At Dg. Submission Date for this Tender is 02-03-2021. Electrical Maintenance Tenders in GE (East) Delhi Cantt-10 Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

26824248
Corrigendum : Repair To Point Wiring And Connected Works At Dgrr In Rpso Complex And Repair/Maintenance Of Summer Appliances And Connected Items In The Area Of Age E/M Under Ge East Delhi Cantt-10 ( Ge/De-74/2020-21 ) Repair To Point Wiring And Connected Works At Dg
Open Tender
Indian
Delhi
GE (East) Delhi Cantt-10
02-03-2021

Tender Details

Repair To Point Wiring And Connected Works At Dgrr In Rpso Complex And Repair/Maintenance Of Summer Appliances And Connected Items In The Area Of Age E/M Under Ge East Delhi Cantt-10 ( Ge/De-74/2020-21 ) Repair To Point Wiring And Connected Works At Dgrr In Rpso Complex And Repair/Maintenance Of Summer Appliances And Connected Items In The Area Of Age E/M Under Ge East Delhi Cantt-10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Feb-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-03-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 78800.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIR TO POINT WIRING AND CONNECTED WORKS AT DGRR IN RPSO COMPLEX AND REPAIR/MAINTENANCE OF SUMMER APPLIANCES AND CONNECTED ITEMS IN THE AREA OF AGE E/M UNDER GE EAST DELHI CANTT-10
Sl. No. Item Code / Make Quantity Units
1 1 Taking down unserviceable ceiling/exhaust fan any sweep from the site for repair/replacement and refixing at the same site after cleaning/greasing/oiling. (Note : Rewinding and other item of the fan will be measured and paid separetely) 4000 Each
2 2 Rewinding of ceiling fan 1200/1400mm with super enamelled copper winding wire of required size duly varnishing including greasing/oiling, replacement of unsv bearing commissioning and testing to the entire satisfaction of Engr-in-Charge, complete all as specified and as directed. 3400 Each
3 3 Rewinding of exhaust fan/Fresh air/Wall Fan/ Pedastal fan of any size and make (225mm to 300mm sweep) with super enamelled copper winding wire of required size duly varnishing including greasing/oiling, replacement of unsv bearing commissioning and testing to the entire satisfaction of Engr-in-Charge, complete all as specified and as directed. 500 Each
4 4 All as per description of Srl item No. 3 here-in-before but 375mm sweep. 50 Each
5 5 All as per description of Srl item No. 3 here-in-before but 450mm sweep. 50 Each
6 6 S&F in replacement ball bearing No 6201/6202 or other size suitable for ceiling/Exhaust fan, complete all as specified and as directed. 200 Each
7 7 Replacement of motor with PVC blades suitable for any type fresh air/ventilating fan with copper wound motor, complete all as specified and as directed. 100 Each
8 8 Replacement of motor with GI blade suitable for 225/250/300mm sweep exhaust fan with copper wound motor, complete all as specified and as directed. 50 Each
9 9 Replacement down rod of size 150 to 300mm long for hanging ceiling fan, complete all as specified and as directed. 200 Each
10 10 Ceiling fan 1200mm sweep, 240 V, DB, 5 star rating, 50 Hz, single phase, with step type electronic regulator having 5 step speed control, complete all as specified and as directed. 414 Each
11 11 Ceiling fan 1400mm sweep, 240 V, DB, 5 star rating, 50 Hz, single phase, with step type electronic regulator having 5 step speed control, complete all as specified and as directed. 100 Each
12 12 Ventilating fan 250 mm sweep plastic body type including self closing louver and making all electric connections complete all as specified and as directed. 130 Each
13 13 Ventilating fan 200 mm sweep plastic body type including self closing louver and making all electric connections complete all as specified and as directed. 104 Each
14 14 Exhaust fan 300mm sweep, single phase, DB, 240 volts, metallic body including suitable size self closing louver and making all electric connections complete all as specified and as directed. 100 Each
15 15 Pedestal fan 450 mm sweep (faratta type) metallic body including and making all electric connections complete all as specified and as directed. 10 Each
16 16 Wall mounted fan 400 mm sweep metallic body including and making all electric connections complete all as specified and as directed. 60 Each
17 17 Desert cooler grass suitable for desert coolers of any size and type complete all as specified and as approved by Engr-in-Charge. 10 Each Set of Three
18 18 Replacement Desert cooler water pump, 240 volts, 50Hz suitable for desert coolers of any size and type, complete all as specified and as directed.\n 5 Each
19 19 Replacement Desert cooler fan motor, 240 volts, 50Hz suitable for desert coolers of any size and type, complete all as specified and as directed.\n 5 Each
20 20 Replacement Desert cooler regulator three steps type, 240 volts, 50Hz suitable for desert coolers of any size and type, complete all as specified and as directed.\n 5 Each
21 21 Replacement Desert cooler fan blades, 240 volts, 50Hz suitable for desert coolers of any size and type, complete all as specified and as directed.\n 5 Each
22 22 Replacement plastic body capacitor of cap 2.5/3.15 mfd with wire suitable for ceiling fan 1200/1400mm and making connection complete all as specified and as directed. 3000 Each
23 23 All as per description of Srl item No. 22 here-in-before but of 4.0 mfd capacity. 50 Each
24 24 Replacement of MS clamps of fan rod including bolts, nuts, washers and split pin etc., suitable for 1200/1400mm sweep ceiling fan, complete all as specified and as directed. 300 Each
25 25 Replacement of PVC canopy of fan rod suitable of 1200/1400mm sweep fan, complete all as specified and as directed. 200 Each
26 26 Replacement of twin twisted flexible, PVC insulated, unsheathed, multistranded copper conductor wire of size 0.75Sqmm, complete all as specified and as directed. 3000 RM
27 27 Taking down Window/Split Type Air Conditioner of any make, size of 1.5/2 Ton capacity from existing site including provisioning of dismantling all electrical items/connected parts such as relay capacitor, compressors grills etc and spray cleaning by means of electric air blower and water descaling by using acid on both side of cooling coil and condenser cleaning with nylon brush and washing with clean water to ensure proper cleaning before reassembling complete unit and refixing at site including testing and commissioning complete all as specified & as directed at site to the entire satisfaction of GE. Note :- (a) Parts found defective after dismantling of ACs requiring replacement will be measured and paid separately under relevant items described here in after however refilling of refrigerant gas and other parts required for dismantling/reassembling of the ACs will be deemed to be included in the quoted rate. 15 Each Job
28 28 Replacement of rotary type compressor for window type AC cap 1.5 TR Make and type as per existing compressor making suction pipe and discharge pipe connections with copper welding/brazing making it leak proof. Pressure testing vacuuming and charging of refrigerant, complete all as specified and as directed. 2 Each
29 29 Replacement of rotary type compressor for Split AC cap 1.5 TR Make- and type as per existing compressor making suction pipe and discharge pipe connections with copper welding/brazing making it leak proof. Pressure testing vacuuming and charging of refrigerant, complete all as specified and as directed. 2 Each
30 30 Replacement of rotary type compressor for Split AC cap 2 TR make and type as per existing compressor making suction pipe and discharge pipe connections with copper welding/brazing making it leak proof. Pressure testing vacuuming and charging of refrigerant, complete all as specified and as directed. 2 Each
31 31 Replacement of starting relay SR-1622, complete all as specified and as directed. 2 Each
32 32 Replacement of starting relay 3 or 4 terminal with connecting leads suitable for any type and make of window air conditioner of 1.5 Ton capacity, complete all as specified and as directed. 2 Each
33 33 Replacement of 1.5 TR window type AC Kit having (a) Condenser (b) evaporator (c) Condenser motor with blower but without compressor complete all as specified & directed. MAKE : RENUTRAL / GODREJ / WHIRLPOOL/LG/VOLTAS. 2 Each
34 34 Rectification of leakage in window type/Split AC’s cap 1.5/2 TR by pressure testing making it leak proof by copper welding/brazing vacuming and charging of refrigerant R-22 complete all as specified & directed 2 Each
35 35 Replacement of front grill suitable for any type and make of window air conditioner 1.5 T R capacity having good aesthetic look good quality as per sample/at site of any make/model approved by GE, complete all as specified and as directed. 2 Each
36 36 Outdoor unit for split type AC 1.5 TR complete with compressor condenser coil condenser Motor fan etc., complete all as specified and as directed. 2 Each
37 37 Replacement of double shaft fan motor 1/5 HP Make and type as per existing motor, complete all as specified and as directed. 2 Each
38 38 Replacement of capacitor Running Cap 36 to 45 Mfd suitable for operating voltage 240 Volt, 50 HZ, complete all as specified and as directed. 2 Each
39 39 Replacement of capacitor Running Cap 55-60 Mfd suitable for operating voltage 240 Volt, 50 HZ, complete all as specified and as directed. 2 Each
40 40 Replacement of starting capacitor 80-100 Mfd, complete all as specified and as directed. 2 Each
41 41 Replacement of starting capacitor 120 Mfd, complete all as specified and as directed. 2 Each
42 42 Replacement of air filter element for 1.5 ton window type air conditioner of any make and type as per sample, complete all as specified and as directed. 2 Each
43 43 Replacement of thermostat suitable for any type and make of window Air conditioner 1.5 ton capacity, complete all as specified and as directed. 2 Each
44 44 Replacement of blower motor 0.5 HP with blower blade assembly complete in all respect for operating voltage 240 volts, 50 HZ and for any type or make of window air conditioner of 1.5/2 ton capacity, complete all as specified and as directed. 2 Each
45 45 Replacement of swing motor complete in all respect for operating voltage 240 volts 50 HZ and for any type and Make of window /Split type air conditioner of 1.5/2 Ton capacity, complete all as specified and as directed. 2 Each
46 46 Replacement of blower of blower motor for split type AC 1.5 /2 TR Make and type as per existing motor, complete all as specified and as directed. 2 Each
47 47 Replacement of blower motor capacitor 6 mfd suitable for operating voltage 240 volt, 50 HZ, complete all as specified and as directed. 2 Each
48 48 Replacement of gun metal bush suitable for blower motor of any type and make of window type AC of 1.5/2 Ton capacity, complete all as specified and as directed. 2 Each
49 49 Rewinding for blower fan motor of window / Split type AC 1.5 TR capacity with proper gauge super enammelled of copper wire not less than 300 gm/unit including testing etc., complete all as specified and as directed 2 Each
50 50 Disconnecting electrical connection and taking down/removing unserviceable single phase voltage stabilizer 4 KVA or 5 KVA capacity of any make and transporting same to MES Yard for annual repair /servicing /cleaning /maintenance. Dismantling the stabilizer segregating unserviceable/wornout parts, carryout repair including replacement of worn out parts, rewinding burnt out transformer as per existing reassembling all components and transporting the same upto its original location, fitting/fixing and testing for effective working complete all as specified and as directed. Note: New spares shall be measured and paid as supply only here-in-after separately. However spare not mentioned in this schedule and required for smooth functioning of stabilizers are deemed to be included in the quoted rate under this item. 10 Each Job
51 51 Replacement cut off relay for any type of make voltage stabilizer 4/5 KVA of any type and make, complete all as specified and as directed. 2 Each
52 52 Replacement of electronic (PCB) for circuit plate for voltage stabilizer 4 KVA or 5 KVA capacity of any make and type, complete all as specified and as directed. 2 Each
53 53 Replacement Volt meter for voltage stabilizer 4 KVA or 5 KVA capacity of any make and type, complete all as specified and as directed. 2 Each
54 54 Replacement Fuse grip for voltage stabilizer 4 KVA or 5 KVA capacity of any make and type, complete all as specified and as directed. 2 Each
55 55 Replacement Control transformer for voltage stabilizer 4 KVA or 5 KVA capacity of any make and type, complete all as specified and as directed. 2 Each
56 56 Low/High Voltage Cut off Switch, complete all as specified and as directed. 2 Each
57 57 Brass bushes suitable for 3 to 5 KVA voltate stabilizer, complete all as specified and as directed. 2 Each
58 58 Thimbles for cable connection of size suitable for Voltage Stabilizer 3 to 5 KVA, complete all as specified and as directed. 20 Each
59 59 Replacement of MCB SP C Curve type, 10 kA, 10 to 32 Amp, with over load and short circuit protection, complete all as specified and as directed. 168 Each
60 60 Replacement of MCB SPN C Curve type, 10 kA, 40 to 63 Amp, with over load and short circuit protection, complete all as specified and as directed. 24 Each
61 61 Single pole and netural enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps, ccomplete all as specified and as directed. 28 Each
62 62 Replacement Voltage stablizer 4KVA Capacity, 240 Volts, 50 HZ, complete all as specified and as directed. 2 Each
63 63 Taking down old unserviceable point wiring from existing conduit / batten type (light, fan, socket or power point) such as switches, ceiling rose, pendent holder, regulator and socket etc and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, complete all as specified and as directed. 681 Per point
64 64 Point wiring with 1.5Sqmm (nominal area) FRLS PVC insulated un-sheathed and multistranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers including cutting in chases and FRLS PVC insulated unsheathed 1.5Sqmm copper conductor mulistranded earth wire, connecting to common earth dolly with and including metal flush box of suitable size for fixing switches/sockets etc complete all as specified and as directed for the following:-\n(Note : The cost of Metal boxes and cover plates etc shall be deemed to be included in quoted rate.)\n(a) One light point / fan point controlled by one 1-way switch/ bell push 340 Per point
65 65 (b) One socket outet point 5 amps on the same board. 55 Per point
66 66 (c) One socket outet point 5 amps on the independent board. 146 Per point
67 67 All as per description of Srl item No. 64 here-in-before but with 2.5Sqmm FRLS copper wire with 1.5Sqmm FRLS copper earth wire for 15 Amp power point. 140 Per point
68 68 Replacement of Switch piano flush type, single pole, one way, 5/6 Amps complete all as specified and as directed. 541 Each
69 69 Replacement of socket two-in-one, 5 pin, 5/6 Amp universal type complete all as specified and as directed. 201 Each
70 70 Replacement of switch 16 Amp,single pole one way complete all as specified and as directed. 140 Each
71 71 Replacement of socket out let 6 pin, two-in-one type with 6 Amp & 16 Amp, flush type complete all as specified and as directed. 140 Each
72 72 Replacement of Modular switch 6 Amp, 1 way, 1 module size, complete all as specified and as directed. 361 Each
73 73 Replacement of Modular switch 16 Amp, 1 way, 1 module size with indicator lamp, complete all as specified and as directed. 120 Each
74 74 Replacement of Modular socket 6 Amp, 2/3 pin, universal type, 2 module size, complete all as specified and as directed. 120 Each
75 75 Replacement of Modular socket 16 Amp multipurpose shuttered type, 2 module size with indicator lamp, complete all as specified and as directed. 120 Each
76 76 Replacement of Modular Fan regulator step type, 120 watts, 2 Module size, complete all as specified and as directed. 14 Each
77 77 Replacement of Modular Bell push switch 6 Amp 1 module size, complete all as specified and as directed. 4 Each
78 78 Replacement of Modular TV socket (RJ 11 Socket Jack) 01 Module size socket as per site requirement, complete all as specified and as directed. 5 Each
79 79 Replacement of Modular Telephone socket Jack 01 Module size socket, complete all as specified and as directed. 15 Each
80 80 Replacement of Bell DINGDONG type, 6 Amp, 240 volts, SP, complete all as specified and as directed. 4 Each
81 81 Replacement of Ceiling rose, insulated body, 3 terminal, 240 volts, 5 Amps and making good surface as original by plastering and whitewash/ colour/ distemper etc., complete all as specified and as directed. 98 Each
82 82 Replacement of MCCB Incommer Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, VTPN 08 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc and making all necessary connections, complete all as specified and as directed. \n 2 Each
83 83 Replacement of MCCB Incommer Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, VTPN 04 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc and making all necessary connections, complete all as specified and as directed. \n 4 Each
84 84 Replacement of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 12 way, 240 volts with bus bar rating 200 Amps including dust and vermin proof and making all necessary connections, complete all as specified and as directed. \n 3 Each
85 85 Replacement of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 04 way, 240 volts with bus bar rating 200 Amps including dust and vermin proof and making all necessary connections, complete all as specified and as directed. \n 1 Each
86 86 Replacement of MCCB triple pole, 415 Volt adjustable type 160 Amp with breaking cap 36 KA with over load and short circuit protection, complete all as specified and as directed. 2 Each
87 87 Replacement of MCCB triple pole, 415 Volt adjustable type 125 Amp with breaking cap 36 KA with over load and short circuit protection, complete all as specified and as directed. 4 Each
88 88 Replacement of LED tube light fitting 22 watt, wall mounting type with and including all electric connections with two core PVC insulated, PVC sheathed copper conductor flexible cable, complete all as specified and as directed. 70 Each
89 89 Replacement of 12 watt LED mirror light fitting and making all electric connections, complete all as specified and as directed. 4 Each
90 90 Replacement of Energy efficient wall mounted LED Bulk Head luminaire 10W made of die cast Aluminium with Opal diffuser IP-65, complete all as specified and as directed. 10 Each
91 91 Replacement of LED security light luminaire 45 watt (white) pressure die cast aluminium housing with heat resistance toughned glass & IP- 66 protection with and including driver/transformer, complete all as specified and as directed. \n 20 Each
92 92 Replacement of security light fitting bracket, 1.5 mtr long made out of galvanized iron pipe light grade suitable size of security light fitting complete with nut, bolts, washer etc inclusive of one primer coat, one under coat and one finishing coat of silver paint, complete all as specified and as directed. 20 Each
93 93 Replacement of recess mounting 2x2 square flat panel ultra slim scoop LED light 36/42 W cool white 5600-6000K, input voltage 50HZ with driver/transformer ect suitable for AS/GB/POP ceiling including making electric connection, complete all as specified and as directed. 84 Each
94 94 Replacement of change over switch off load type AC 415 Volt , TPN 250 Amp with side handle operation heavy duty in sheet metal enclosure, complete all as specified and as directed. 4 Each
95 95 Replacement of earthing complete with GI earth plate electrode 600 mm x 600mm x 6mm thick burried directly in ground not less than 2.25 mtrs below ground level, with top edge of the plate not less than 1.5 mtrs deep below normal ground level, connected to galvanised earth wire 4mm by means of bolts, nuts check nuts to earth test point including necessary PCC 1:2:4 type B-1 pit, cover frame, GI pipe 15mm dia light grade for protection of earthing lead and GI pipe 20 mm dia for watering pipe with funnel, wire mesh, salt, charcoal dust and excavation, complete all as specified and as directed. 6 Each Set
96 96 Replacement of TV Wiring with Co axial RG-6 heavy duty PVC insulated, PVC sheathed cable having single strand of 0.7 mm dia taped suitable for telephone wiring and making all necessary connections from terminal box to TV socket, drawn in separate concealed PVC conduit, complete all as specified and as directed. 130 RM
97 97 Replacement of telephone Wiring with twin core PVC insulated, PVC sheathed cable having single strand of 0.7 mm dia taped suitable for telephone wiring and making all necessary connections from terminal box to telephone socket, drawn in separate concealed PVC conduit, complete all as specified and as directed. 430 RM
98 98 Replacement of submain wiring complete with 2 x 4.0Sqmm (nominal area) FRLS, PVC insulated, unsheathed and multistandard copper conductor cable ISI marked, and 1 x 2.5 sqmm as earth wire in and including PVC conduit of size 20 mm dia, medium grade and conduit fitting such as tees, bends, elbow, reducers etc. complete all as specified and as directed. 300 RM
99 99 All as per description of srl item No. 98 here-in-before but with 2 run of 6.0 Sqmm FRLS copper wire with 4.0 Sqmm FRLS copper cable as earth wire, complete all as specified and as directed. 750 RM
100 100 All as per description of srl item No. 98 here-in-before but with 2 run of 10.0 Sqmm FRLS copper wire with 6.0 Sqmm FRLS copper cable as earth wire, complete all as specified and as directed. 55 RM
101 101 Rewinding of motor of shutter door upto 5 HP with super enamelled copper winding wire of required size duly varnishing including greasing/oiling, replacement of unsv bearing, including taking down the motor and refixing after rewinding, commissioning and testing to the entire satisfaction of Engr-in-Charge, complete all as specified and as directed. 10 Each
102 102 Replacement High pressure booster pump with 8 ltr capacity pressure tank, coupled with electric motor of capacity 0.50 HP, 230 volts, single phase, 50 Hz incl connecting accessories of GI i.e bend, nipple, socket, tee of requisite size etc incl cutting of existing pipe, complete all as specified and as directed. 6 Each
103 103 Replacement High pressure booster pump with 24 ltr capacity pressure tank, coupled with electric motor of capacity 1 HP, 230 volts, single phase, 50 Hz incl connecting accessories of GI i.e bend, nipple, socket, tee of requisite size etc incl cutting of existing pipe, complete all as specified and as directed. 1 Each
104 104 Replacement electric motor of capacity 0.50 HP, 230 volts, single phase, 50 Hz for booster pump, complete all as specified and as directed. 10 Each
105 105 Replacement electric motor of capacity 1 HP, 230 volts, single phase, 50 Hz for booster pump, complete all as specified and as directed. 2 Each
106 106 Replacement Cylinder 8 ltr capacity for booster pump, complete all as specified and as directed. 10 Each
107 107 Replacement Cylinder 24 ltr capacity for booster pump, complete all as specified and as directed. 2 Each
108 108 Replacement pressure guage dial type for booster pump 0.5/1 HP, complete all as specified and as directed. 5 Each
109 109 Replacement of starting relay for booster pump 0.5/1 HP, complete all as specified and as directed. 5 Each
110 110 NOTE :- For minimum fair wages ,EPF and payment to labour employed, refer Sch A Note No-16,17 and Special Condition 22 of this tender. Contractor must produce all the relevent record such as payment made to labour, EPF etc at the time of payment of RARs/Final bill. No payment will be released to contrator without producing the proper record. \n
Disclaimer :