Tender For Civil Works - Bridge Construction Work -L030-T03 To Oya Hazi Tola ( Track6 ) Local River
Tender Value
3.49 Crore
Estimated cost
Bid Submission
08 Feb 2021
0 days left
EMD
6.98 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
MANIHARI → Bihar
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
tender for Civil Works - Bridge Construction work -L030-T03 To Oya Hazi Tola ( Track6 ) Local River
BOQ
| Name of Work: L030-T03 TO OYA HAZI TOLA (TRACK6)Local River 1ST CUT , Bridge Length - 63.27 M , Block-Amdabad , District - Katihar | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. | |||
| 2 | 2 | i) Upto 3m depth | 702.704 | cum | |
| 3 | 3 | ii) 3m to 6m depth | 287.194 | cum | |
| 4 | 4 | Providing and laying of PCC M15 levelling course 100mm thick below the pile cap. | 21.283 | cum | |
| 5 | 5 | R.C.C. grade M 35 in Pile Foundation complete as per Dwg & Tech Specification. II. PCC Grade M-15 (Levelling Course) | 253.368 | cum | |
| 6 | 6 | Bored cast-in-situ M35 grade R.C.C. Pile excluding Reinforcement complete as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m. Note:- All Necessary test have to be performed by the contractor during construction activity & after construction as per engineer incharge. Dynamic Load Test , Static Load Test , Pile Integrity Test etc. II. 1200 mm Dia | 436 | mtr | |
| 7 | 7 | Carrying out load test on any pile as per standard procedure laid down in the IS:2911 specification including construction of test cap, dismantling the cap after test and cleaning the site and maintaining complete records of load. Note:- All Necessary test have to be performed by the contractor during construction activity & after construction as per engineer incharge. Dynamic Load Test , Static Load Test , Pile Integrity Test etc. Pile Cap in RCC M-35 | |||
| 8 | 8 | a) Initial Load Test on test pile for 2.5 times the design load specified in Drawings 1.2 m Dia Pile | 1 | nos | |
| 9 | 9 | b) Routine pile load test on pile for 1.5 times the design load specified in Drawing 1.2 m Dia Pile (2% of piles in total). | 1 | nos | |
| 10 | 10 | c) Horizontal pile load test on pile for 1.5 times the design load specified in Drawings 1.2 m Dia Pile (2% of piles in total) . | 1 | nos | |
| 11 | 11 | Supplying, fitting and placing TMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 | 61.961 | tonne | |
| 12 | 12 | R.C.C. grade M-35 in Substructure complete as per Dwg & Tech Specification | |||
| 13 | 13 | i) Upto 5m height (Using Concrete Mixer) | 231.834 | cum | |
| 14 | 14 | ii) From 5m upto 10m height (Using Concrete Mixer) | 20.095 | cum | |
| 15 | 15 | Supplying, fitting and placing TMT bar reinforcement (Fe 500) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 | 23.861 | tonne | |
| 16 | 16 | Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, completre assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per IRC: 83 part-I & II respectively and other parts conforming to BS: 5400, section 9.1 & 9.2 and clause 2006 of MoRTH Specifications complete asper drawing and approved technical specifications. | 18 | nos | |
| 17 | 17 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 | 82 | nos | |
| 18 | 18 | Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 I) Sandy Material | 316.558 | cum | |
| 19 | 19 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8 | 130.967 | cum | |
| 20 | 20 | Providing and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 II. RCC M-35 (Height 5m to 10m) | 259.076 | cum | |
| 21 | 21 | Construction of Ralling Kerb Providing and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 | 16.88 | cum | |
| 22 | 22 | Supplying, fitting and placing HYSD bar reinforcement (Fe 500) in superstructrue complete as per drawings and technical specification Clauses 1002, 1010 & 1202 | 50.274 | tonne | |
| 23 | 23 | Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 | 25.74 | cum | |
| 24 | 24 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 | 139.04 | mtr | |
| 25 | 25 | Drainage Spouts complete as per drawing and technical specifications Clause 1209 | 25 | nos | |
| 26 | 26 | P.C.C. M-15 ordinary grade (1:2.5:5) levelling course below approach slab complete as per drawing and technical specificatios Clauses 800 & 1211. | 5.528 | cum | |
| 27 | 27 | Reinforced Cement Concrete M-25 grade approach slab including reinforcement and formwork complete as per drawing and technical specifications Clauses 800 and 1211 | 11.55 | cum | |
| 28 | 28 | Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.) | 25.6 | mtr | |
| 29 | 29 | White Washing of Parapet Walls\nWhite washing two coats on parapet walls and tree trunks including preparation of surface by cleaning, scapping, etc. as pre technical specification Clause 1915 | 152.944 | SQM | |
| 30 | 30 | Providing and laying boulder pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 | 653.967 | cum | |
| 31 | 31 | Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302 | 326.984 | cum | |
| 32 | 32 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. | 103.546 | cum | |
| 33 | 33 | Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing not less than 25 Kg, laid dry complete as per drawing and technical specifications Clause 1301. I. Rubble stone laid in cement mortar 1:3 | 103.114 | cum | |
| 34 | 34 | Clearing and Grubbing Road Land (By manual means) including uprooting wild vegetation , grass ,bushes ,shrubs , saplings and trees of girth upto 300mm , removals of stumps of such trees cut earlier & disposal of unserviceable materials & stacking of serviceable materials to be used or auctioned upto a lead of 1000 m including removal and disposal of top organic soil not exeeding 150mm in thickness as per technical specification - clause 201.1 and direction of E/I | 0.16 | ha | |
| 35 | 35 | Construction of embankment with approved material deposited from road way cutting and excavation from drain and foundation of other structures and excavated with an average lead of 50 m graded and compacted to meet requirement of tables 300.1 and 300.2 as per technical specification clause 301.5 | 593.939 | cum | |
| 36 | 36 | Construction of Embankment with material obtained from borrow pits with a lift upto 1.5 m , transporting to the site spreading , grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 . | 17499.1 | cum | |
| 37 | 37 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. | 652.5 | cum | |
| 38 | 38 | Granular Sub-base with Well Graded Material (Table 400.1) For Grading II Material Construction of granular sub-base by providing well graded material, spreading in uniform layers with tractor mounted grader arrangement on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. | 162 | cum | |
| 39 | 39 | Road Marking With Hot Applied Thermoplastic Compound With Reflectorising Glass Beads On Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. | 40 | SQM | |
| 40 | 40 | WBM Grading 3 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. | 56.25 | cum | |
| 41 | 41 | Prime Coat (Low porosity) Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. | 750 | SQM | |
| 42 | 42 | Providing and applying tack coat with bitumen emulsion (RS ) using emulsion distributor @ 0.2 to 0.25 kg per sq m on the prepared bituminous surface cleaned with hydraulic broom as per technical specification clause 503. | 750 | SQM | |
| 43 | 43 | Mix Seal Surfacing Type B Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509 Type B | 750 | SQM | |
| 44 | 44 | Providing and fixing of semi reflective cautionary , mandatory and informatory sign board as per IRC :67 made of 1.5 mm thick MS steel duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per clause 1701.3.9 of MORD for rural road of required shade and colour supported and welded on 47mmx47mmx12swg sheet tube firmly fixed to the ground by mean of properly designed foundation with M15 grade cement concrete 450x450x600 mm ,600mm below ground level as per approved drawing clause 1701.2.2. | 2 | nos | |
| 45 | 45 | (I)Providing and Fixing 'Logo' of PMGSY Project | 1 | nos | |
| 46 | 46 | ( III ) Providing & Fixing of LOGO of \"Citizen Information Board\" | 1 | nos | |
| 47 | 47 | GST @ 12 % = | 1 | nos | |
| 48 | 48 | LABOUR CESS @ 1 % = | 1 | nos | |
| 49 | 49 | SEIGNIORAGE FEE 10% ON CONSTRUCTION = | 1 | nos | |
| 50 | 50 | 1st Year Maintenance cost | 1 | year | |
| 51 | 51 | 2nd Year Maintenance cost | 1 | year | |
| 52 | 52 | 3rd Year Maintenance cost | 1 | year | |
| 53 | 53 | 4th Year Maintenance cost | 1 | year | |
| 54 | 54 | 5th Year Maintenance cost | 1 | year | |
| 55 | 55 | GST @ 12 % = | 1 | nos | |
| 56 | 56 | LABOUR CESS @ 1 % = | 1 | nos | |
| 57 | 57 | SEIGNIORAGE FEE 10% ON MAINTENANCE = | 1 | nos |
AI Tender Summary
Tender Timeline
Feb 02, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 08, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 10, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender