Construction Of Ramanattukara Municipal Office Building - Retender Building Including Civil , Plumbing , Electrical Works , Etc, Ramanattukara-Kerala

IMPACT Kerala Limited has published Construction Of Ramanattukara Municipal Office Building - Retender Building Including Civil , Plumbing , Electrical Works , Etc. Submission Date for this Tender is 12-03-2021. Electrical Maintenance Tenders in Ramanattukara Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

26815890
Construction Of Ramanattukara Municipal Office Building - Retender Building Including Civil , Plumbing , Electrical Works , Etc
Open Tender
Indian
Kerala
Ramanattukara
12-03-2021

Tender Details

Construction Of Ramanattukara Municipal Office Building - Retender Building Including Civil , Plumbing , Electrical Works , Etc

Key Value

Document Fees
INR 17700 /-
EMD
INR 500000.0 /-
Tender Value
Refer document

BOQ Items

Work Name : Construction of Office Building for Ramanattukara Municipality
Sl. No. Item Description Item Code / Make Quantity Units
1 1 NEW OFFICE BUILDING - CIVIL BI01010001010000000000000515BI0100001113
2 1.01 2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared BI01010001010000000000000515BI0100001114 1836 sqm
3 1.02 od197044/2020_2021 : Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by rolling with power roller of minimum 8 tonnes, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge. BI01010001010000000000000515BI0100001115 3900.1 cum
4 1.03 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil BI01010001010000000000000515BI0100001116 107.052 cum
5 1.04 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) BI01010001010000000000000515BI0100001117 110.346 cum
6 1.05 od187229/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. All work upto plinth level BI01010001010000000000000515BI0100001118 145.996 cum
7 1.06 od187257/2020_2021 : Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. BI01010001010000000000000515BI0100001119 1150.83 cum
8 1.07 od187280/2020_2021 : Extra for providing richer mixes at all floor levels. Providing M-35 grade concrete instead of M-25 grade BMC/RMC. BI01010001010000000000000515BI0100001120 711.294 cum
9 1.08 od187300/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. All work above plinth level upto floor V level BI01010001010000000000000515BI0100001121 1055.39 cum
10 1.09 5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers BI01010001010000000000000515BI0100001122 3819.66 sqm
11 1.1 5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts BI01010001010000000000000515BI0100001123 1419.96 sqm
12 1.11 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform BI01010001010000000000000515BI0100001124 3719.05 sqm
13 1.12 5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) BI01010001010000000000000515BI0100001125 214.377 sqm
14 1.13 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete BI01010001010000000000000515BI0100001126 316.051 sqm
15 1.14 20.2.4 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).500 mm dia piles BI01010001010000000000000515BI0100001127 837 metre
16 1.15 20.2.5 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).600 mm dia piles BI01010001010000000000000515BI0100001128 1026 metre
17 1.16 od184175/2020_2021 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap). 700 mm dia piles BI01010001010000000000000515BI0100001129 540 metre
18 1.17 od197057/2020_2021 : Boring by mechanical means including diamond core cutting in hard rock for pile socketing, including getting out the excavated material and disposal of surplus excavated material as directed, within a lead of 50 m. (For 500mm, 600mm, 700mm piles) BI01010001010000000000000515BI0100001130 50.5 metre
19 1.18 od199665/2020_2021 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single pile above 50 tonne and upto 200 tonne capacity Initial test BI01010001010000000000000515BI0100001131 3 per test
20 1.19 od199672/2020_2021 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single pile above 50 tonne and upto 200 tonne capacity Routine test BI01010001010000000000000515BI0100001132 3 per test
21 1.2 15.2.1 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) BI01010001010000000000000515BI0100001133 14.511 cum
22 1.21 5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more BI01010001010000000000000515BI0100001134 228792 kg
23 1.22 50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 (1 cement: 6 coarse sand) etc complete. BI01010001010000000000000515BI0100001135 397.04 cum
24 1.23 50.6.1.3 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM 1:6 (1 cement :6 coarse sand) etc complete BI01010001010000000000000515BI0100001136 383.911 cum
25 1.24 6.27.2 : Brick work with common burnt clay modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand). Above plinth level and upto floor V level BI01010001010000000000000515BI0100001137 129.186 cum
26 1.25 od149727/2020_2021 : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:6 (1 cement : 6 coarse sand) BI01010001010000000000000515BI0100001138 54.958 sqm
27 1.26 13.1.1 : 12 mm cement plaster of mix:1:4 (1 cement : 4 fine sand) BI01010001010000000000000515BI0100001139 9217.99 sqm
28 1.27 13.16.1 : 6 mm cement plaster of mix:1:3 (1 cement : 3 fine sand) BI01010001010000000000000515BI0100001140 5158.72 sqm
29 1.28 od147534/2020_2021 : Providing and laying LEPPATO FINISHED Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Architect. BI01010001010000000000000515BI0100001141 344.079 sqm
30 1.29 od147536/2020_2021 : Labour for fixing, edge rounding and final polishing of Granite edges for steps an etc BI01010001010000000000000515BI0100001142 792.401 metre
31 1.3 8.13.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as\nper the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with\ncement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as\nspecified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent. BI01010001010000000000000515BI0100001143 706.114 sqm
32 1.31 od197193/2020_2021 : Providing and laying full body vitrified matt floor tiles in different sizes (10-15mm thickness) with water absorption less than 0.08% and conforming to IS : 15622, of approved make like Johnson/ Kajaria/ Rak/ Nitco/ Equivalent with a basic price of not less than Rs.1100/sqm in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm. BI01010001010000000000000515BI0100001144 1990.16 sqm
33 1.32 od197195/2020_2021 : Providing and laying full body Vitrified matt tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make like Johnson/ Kajaria/ Rak/ Nitco/ equivalent with a basic price not less than Rs.1100/sqm, in all colours & shade, in skirting, recessed into wall, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm BI01010001010000000000000515BI0100001145 213.199 sqm
34 1.33 od197197/2020_2021 : Providing and laying full body vitrified matt floor tiles in different sizes (10-15mm thickness) with water absorption less than 0.08% and conforming to IS : 15622, of approved make like Johnson/ Kajaria/ Rak/ Nitco/ Equivalent with a basic price of not less than Rs.1500/sqm in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm BI01010001010000000000000515BI0100001146 273.388 sqm
35 1.34 od197201/2020_2021 : Providing and laying full body Vitrified matt tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make like Johnson/ Kajaria/ Rak/ Nitco/ equivalent with a basic price not less than Rs.1350/sqm, in all colours & shade, in skirting, recessed into wall, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm BI01010001010000000000000515BI0100001147 14.497 sqm
36 1.35 od197203/2020_2021 : Providing and laying full body vitrified matt floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make like Johnson/ Kajaria/ Rak/ Nitco/ Equivalent with a basic price of not less than Rs.680/sqm in all colours and shades except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm. BI01010001010000000000000515BI0100001148 251.528 sqm
37 1.36 od197204/2020_2021 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make like Johnson/ Kajaria/ Rak/ Nitco/ equivalent with a basic price not less than Rs.300/sqm, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. BI01010001010000000000000515BI0100001149 914.206 sqm
38 1.37 od197206/2020_2021 : Providing and laying matt finished heavy duty vitrified tile of size 450x450x12mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make like Johnson/ Kajaria/ equivalent with a basic price not less than Rs.645/sqm in all colours and shades in for outdoor floors such as court yard etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. BI01010001010000000000000515BI0100001150 121.68 sqm
39 1.38 od183310/2020_2021 : Providing and paving baby chips around the building BI01010001010000000000000515BI0100001151 128 sqm
40 1.39 od147554/2020_2021 : Providing and fixing of 15cm height platform making with 16mm marine plywood IS710.Grd top panel placed on proper reinforced double thick same grade plywood structures BI01010001010000000000000515BI0100001152 69.92 sqm
41 1.4 2.35.3.1 : Diluting and injecting chemical emulsion for POST -CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration BI01010001010000000000000515BI0100001153 1092.83 sqm
42 1.41 od197207/2020_2021 : Providing and laying semi polished, flamed Cerastone or equivalent (4inch thick) of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, with Buffalo grass in the gap of 2cm including all labour, material, etc. all complete as per the direction of Engineer-in-charge. BI01010001010000000000000515BI0100001154 1420 sqm
43 1.42 8.2.1.1 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Raj Nagar Plain white marble/ Udaipur green marble/Zebra black marbleArea of slab upto 0.50 sqm BI01010001010000000000000515BI0100001155 112.369 sqm
44 1.43 13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. BI01010001010000000000000515BI0100001156 9217.99 sqm
45 1.44 13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) BI01010001010000000000000515BI0100001157 4140.55 sqm
46 1.45 13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm BI01010001010000000000000515BI0100001158 6382.02 sqm
47 1.46 12.20 : Providing and laying pressed clay tiles ( as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete BI01010001010000000000000515BI0100001159 111.671 sqm
48 1.47 9.117.1 : Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm BI01010001010000000000000515BI0100001160 653.35 metre
49 1.48 9.118.2 : Providing and fixing to existing door frames30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. BI01010001010000000000000515BI0100001161 237.705 sqm
50 1.49 od197208/2020_2021 : Providing and fixing factory made uPVC white colour casement / casement cum fixed louvre window uPVC frame along with louvres. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. BI01010001010000000000000515BI0100001162 1.2 sqm
51 1.5 od194725/2020_2021 : Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door with 6mm thick toughened glass comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. BI01010001010000000000000515BI0100001163 15.18 sqm
52 1.51 od197219/2020_2021 : Providing and fixing factory made uPVC white colour sliding glazed door with 6mm toughened glass comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm) BI01010001010000000000000515BI0100001164 12.54 sqm
53 1.52 9.147A.1 : Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required\nlength (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and\nnecessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance\nin dimension i.e. in depth & width of profile shall be acceptable.Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 +/- 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.) BI01010001010000000000000515BI0100001165 9.96 sqm
54 1.53 9.147A.3 : Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required\nlength (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and\nnecessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance\nin dimension i.e. in depth & width of profile shall be acceptable. Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazingbead of appropriate dimension. ( Area of window upto 2.50 sqm). BI01010001010000000000000515BI0100001166 267.283 sqm
55 1.54 9.147B.1 : 543 SUB HEAD : 9 - WOOD & PVC WORK\n9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized\nmild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and\nsilicon sealant shall be paid separately).\nNote: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) BI01010001010000000000000515BI0100001167 47.386 sqm
56 1.55 od147566/2020_2021 : Providing and fixing in position wall panelling at all heights with Saint gobain approved by the Architect, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be in-serted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer's specification as per direction of Engineer-in-Charge all complete. With 15 mm thick fully perforated square/butt edge light weight calcium silicatepanels/ tiles BI01010001010000000000000515BI0100001168 522.789 sqm
57 1.56 od178886/2020_2021 : Providing and fixing Fibre (high impact poly propelene reinforced) cement sheet of good quality in all colours with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete: BI01010001010000000000000515BI0100001169 113.81 sqm
58 1.57 od147569/2020_2021 : Providing & fixing false ceiling at all heights with with 40mm thick Alfaa sandwich panel grey coloured be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. BI01010001010000000000000515BI0100001170 500.514 sqm
59 1.58 10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. BI01010001010000000000000515BI0100001171 10767.8 kg
60 1.59 13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work BI01010001010000000000000515BI0100001172 534.101 sqm
61 1.6 od147570/2020_2021 : Providing & fixing on decorativetile paving of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately) BI01010001010000000000000515BI0100001173 96.382 sqm
62 1.61 od194803/2020_2021: Providing at all heights, levels and locations powder coated Aluminium trafford sheet 0.50mm thick (Jindal/ Oralium/ Hindalco/ Everlast/ Equivalent). The sheet shall be fixed using self drilling/self tapping SS screws of size 5.5x65 mm with EPDM seal complete upto required pitch in horizontal, vertical or curved surfaces i/c cutting to size and shape whereever required as per specifications, detail drawings and direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealent wherever required etc. but excluding the cost of purlins, rafters and trusses. BI01010001010000000000000515BI0100001174 468.752 sqm
63 1.62 od194805/2020_2021 : Providing at all heights, levels and locations powder coated Aluminium Corrugated sheet 0.46mm thick (Jindal/ Oralium/ Hindalco/ Everlast/ Equivalent). The sheet shall be fixed using self drilling/ self tapping SS screws of size 5.5x65 mm with EPDM seal complete upto required pitch in horizontal, vertical or curved surfaces i/c cutting to size and shape whereever required as per specifications, detail drawings and direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealent wherever required etc. but excluding the cost of purlins, rafters and trusses. BI01010001010000000000000515BI0100001175 96.382 sqm
64 1.63 od194806/2020_2021 : Providing and fixing M.S. round or square bars with M.S. flats at required spacing in frames of windows by welding including priming coat with approved steel primer, all complete as per directions of Engineer-in-charge BI01010001010000000000000515BI0100001176 1959.12 kg
65 1.64 od178568/2020_2021 : Providing and fixing stainless steel Brushed mat finish (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) Weight of steel should check in site and measurement taken in kg. BI01010001010000000000000515BI0100001177 1275.58 kg
66 1.65 10.26.1 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube BI01010001010000000000000515BI0100001178 1478.47 kg
67 1.66 12.51.6 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Gutter (600 mm over all girth) BI01010001010000000000000515BI0100001179 68.74 metre
68 1.67 21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) BI01010001010000000000000515BI0100001180 2835.07 kg
69 1.68 od197225/2020_2021 : Providing and fixing 8mm thick toughened glass panes (Saint Gobain/ Borosil/ La-Opala/ Equivalent) in aluminium partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. (Cost of aluminium snap beading and aluminium structure shall be paid separately) BI01010001010000000000000515BI0100001181 119.538 sqm
70 1.69 od197226/2020_2021 : Providing and fixing 6mm thick toughened glass panes (Saint Gobain/ Borosil/ La-Opala/ Equivalent) in uPVC doors with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. (Cost of shutters paid separately) BI01010001010000000000000515BI0100001182 47.205 sqm
71 1.7 21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness BI01010001010000000000000515BI0100001183 431.419 sqm
72 1.71 od195096/2020_2021 : Providing & fixing coloured float glass panes with putty and glazing clips in uPVC Ventillators all complete as per the drawings and directions of the Engineer-in-charge. 5.5 mm thick glass panes BI01010001010000000000000515BI0100001184 6.48 sqm
73 1.72 22.6 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) BI01010001010000000000000515BI0100001185 998.106 sqm
74 1.73 16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-Charge) BI01010001010000000000000515BI0100001186 4.049 cum
75 1.74 od178633/2020_2021 : Providing and Planting of Buffalo grass for Lawn in Ordinary soil including Breaking clods, Watering, Ramming and Sectioning of spoil bank etc., including all labour charges, etc., complete BI01010001010000000000000515BI0100001187 143.27 sqm
76 1.75 od147572/2020_2021 : WATER CUTTING Providing and casting water cutting with Cement mortar 1:4 with specified measurement according to the direction of the engineer in site and as per the architectural drawing BI01010001010000000000000515BI0100001188 446.131 metre
77 1.76 od195102/2020_2021 : Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing as per the directions of the Engineer-in-charge BI01010001010000000000000515BI0100001189 26.65 sqm
78 1.77 od195117/2020_2021 : Providing and fixing Glass Reinforced Jali works in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 White cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. BI01010001010000000000000515BI0100001190 85.789 sqm
79 1.78 od195129/2020_2021 : Providing cement plastering of 12 mm cement plaster of mix 1:4 (1 cement : 4 fine sand) with chicken mesh in column-wall and beam-wall joints as per the directions of the Engineer-in-charge BI01010001010000000000000515BI0100001191 300.481 sqm
80 1.79 od147578/2020_2021 : Exposed concrete BI01010001010000000000000515BI0100001192 150.378 sqm
81 1.8 od178881/2020_2021 : Providing & fixing Stainless steel lettering for nameboard as per the size mentioned in drawing and quality approved by the Architect including labour charges etc complete - Size of the lettering is 20cm width, 25cm height, 3.3cm thickness each on granite slab fixed in the compound wall BI01010001010000000000000515BI0100001193 1 L.S
82 1.81 od195131/2020_2021 : LANDSCAPING TREES - Digging pits in all kinds of soil and refilling the same with good quality fertile and earth, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead lift etc as directed by engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all complete BI01010001010000000000000515BI0100001194 20 holes
83 1.82 od147580/2020_2021 : SHRUBS: Digging pits in all kinds of soil and refilling the same with good quality fertile and earth, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead lift etc as directed by engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all conveyance, transported without any damage to the root. BI01010001010000000000000515BI0100001195 150 each
84 1.83 od147581/2020_2021 : CREEPERS: Planting creepers 60cm center (type of creeper specified below) by excavating trenches of size 30x30x30cm and refilling with good quality fertile red earth, river sand, dried cow dung manure and leaf mould mixed in the ratio 1:1:1:1, removal of rubbish and surplus earth if any, including leaf lift etc. as directed by engineer in-charge and supplying good healthy cuttings of creepers free of all pests and deseases from source of availability including all conveyance caring and protecting the creeper etc. complete cutting of minimum 60cm length. BI01010001010000000000000515BI0100001196 100 each
85 1.84 od147583/2020_2021 : DUST BIN: Providing and fixing Dust bin inside of park and parking area. including cost of all items. as per design drawings including all necessary labour, lead, lift, etc. complete. BI01010001010000000000000515BI0100001197 3 each
86 1.85 od147584/2020_2021 : ADVERTISEMENT BOARD: Providing and fixing advertisement board. as per design and drawings including all necessary labour, lead, lift, etc. complete - Board with GI Sheet of 1.2mm thickness having a dimension of 2x2.5m fixed on 2” GI pipes of 3mm thickness painted with epoxy paint and lettering BI01010001010000000000000515BI0100001198 1 each
87 2 RETAINING WALL and COMPOUND WALL BI01010001010000000000000515BI0100001199
88 2.01 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) BI01010001010000000000000515BI0100001200 18.828 cum
89 2.02 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size BI01010001010000000000000515BI0100001201 87.032 cum
90 2.03 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete BI01010001010000000000000515BI0100001202 4.4 sqm
91 2.04 5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers BI01010001010000000000000515BI0100001203 234.207 sqm
92 2.05 7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) BI01010001010000000000000515BI0100001204 214.651 cum
93 2.06 5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more BI01010001010000000000000515BI0100001205 8690.3 kg
94 2.07 50.6.1.1 : Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete BI01010001010000000000000515BI0100001206 47.609 cum
95 2.08 6.27.1 : Brick work with common burnt clay modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand).From ground level upto plinth level BI01010001010000000000000515BI0100001207 25.92 cum
96 2.09 13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) BI01010001010000000000000515BI0100001208 385.668 sqm
97 2.1 13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) BI01010001010000000000000515BI0100001209 386.309 sqm
98 2.11 10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. BI01010001010000000000000515BI0100001210 3277.06 kilogram
99 2.12 13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work BI01010001010000000000000515BI0100001211 166.72 sqm
100 3 OPEN WELL BI01010001010000000000000515BI0100001212
101 3.01 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil BI01010001010000000000000515BI0100001213 105.976 cum
102 3.02 od147435/2020_2021 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials. All kinds of soil BI01010001010000000000000515BI0100001214 10.598 cum
103 3.03 od147439/2020_2021 : Extra for open well excavation in all classes of soil from 3 - 4.5m BI01010001010000000000000515BI0100001215 10.598 cum
104 3.04 od147443/2020_2021 : 4 Extra for open well excavation in all classes of soil from 4.5-6m BI01010001010000000000000515BI0100001216 10.598 cum
105 3.05 od147447/2020_2021 : 5 Extra for open well excavation in all classes of soil from 6-7.5m BI01010001010000000000000515BI0100001217 10.598 cum
106 3.06 od147453/2020_2021 : Extra for open well excavation in all classes of soil from 7.50 - 9.00 m BI01010001010000000000000515BI0100001218 10.598 cum
107 3.07 od147457/2020_2021 : Extra for open well excavation in all classes of soil from 9.00 - 10.5 m BI01010001010000000000000515BI0100001219 10.598 cum
108 3.08 od147462/2020_2021 : Extra for open well excavation in all classes of soil from 10.5 - 12.00 m BI01010001010000000000000515BI0100001220 10.598 cum
109 3.09 od147467/2020_2021 : Extra for open well excavation in all classes of soil from 12 - 13.5m BI01010001010000000000000515BI0100001221 10.598 cum
110 3.1 od147474/2020_2021 : Extra for open well excavation in all classes of soil from 13.5 - 15.00 m BI01010001010000000000000515BI0100001222 10.598 cum
111 3.11 60.2.2 : Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete BI01010001010000000000000515BI0100001223 12 hour
112 3.12 50.5.7 : Reinforced cement concrete work in well-staining excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1. 5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) BI01010001010000000000000515BI0100001224 25.106 cum
113 3.13 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more BI01010001010000000000000515BI0100001225 1757.42 kilogram
114 3.14 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) BI01010001010000000000000515BI0100001226 2.208 cum
115 3.15 5.9.12 : Centering and shuttering including strutting, etc. and removal of form for:Well steining BI01010001010000000000000515BI0100001227 244.921 sqm
116 3.16 13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) BI01010001010000000000000515BI0100001228 40.821 sqm
117 4 Gate & Car Park BI01010001010000000000000515BI0100001229
118 4.01 10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works BI01010001010000000000000515BI0100001230 2052.01 kg
119 4.02 50.12.2.1 : Providing & fixing Poly carbonate corrugated sheet 0.8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling / self tapping screw of size (5.5x55 mm) with EPDM seal complete upto any pitch in horizontal/ vertical/ curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size shapes where ever required. BI01010001010000000000000515BI0100001231 77.238 sqm
120 5 PLUMBING ESTIMATE BI01010001010000000000000515BI0100001232
121 5.01 od199921/2020_2021 : Providing and fixing white vitreous china extended wall mounted European water closet of size 780x370x690 mm of approved shape and of superior quality with a price not less than Rs.7000/each, including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre /8 litres), including seat cover, angle cock and health faucet (all of make Jaquar/ equivalent), 15mm dia flexible water inlet pipe, 32mm dia pvc flush pipe, and cistern fittings, nuts bolts and gasket, connection to the soil line core cutting, refinishing etc complete as per the directions of the Engineer-in-charge BI01010001010000000000000515BI0100001233 42 each
122 5.02 od199923/2020_2021 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar and angle cocks of approved make (Jaquar/ equivalent), 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin half pedestal of size 630x450 mm (price not less than Rs.1500/each) with a pair of 15 mm C.P. brass pillar taps BI01010001010000000000000515BI0100001234 35 each
123 5.03 od200635/2020_2021 : Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, angle cock and health faucet (all of superior quality like Jaquar/ equivalent) with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required: Single half stall urinal (price not less than Rs.1600/each) with 5 litre PVC. automatic flushing cistern BI01010001010000000000000515BI0100001235 12 each
124 5.04 od147448/2020_2021 : Supply and Installation of Counter Mount Kitchen sink , PVC Extension pipe and Flange, Standard waste coupling,wall chasing, refinishing etc.including the following :- BI01010001010000000000000515BI0100001236 7 each
125 5.05 od147454/2020_2021 : Supply and Installation of site 15mm dia C.P brass Bib tap with wall flange including cutting and making good the wall wherever required(Jaquar ARI-39037/ equivalent) BI01010001010000000000000515BI0100001237 52 each
126 5.06 od147463/2020_2021 : 6.Supply and Installation of 65mm Dia Butterfly valve including Wall cutting and making good in open terrace complete as required. (Supreme/Finolex/Astral or equivalent) BI01010001010000000000000515BI0100001238 2 no
127 5.07 od147468/2020_2021 : Supply and Installation of 20mm Dia ss stop cock and allied including Wall cutting and making good in bathroom complete as required. (Jaquar Stopcock-Fus-29083k & Allied-Ald089/ equivalent) BI01010001010000000000000515BI0100001239 35 no
128 5.08 od147475/2020_2021 : 9.Supply and Installation of 25mm Dia Brass valve including Wall cutting and making good in bathroom complete as required. (Supreme/Finolex/Astral or equivalent) BI01010001010000000000000515BI0100001240 10 no
129 5.09 od147480/2020_2021 : Supply and Installation of 40mm Dia Brass valve including Wall cutting and making good in open terrace complete as required. (Supreme/Finolex/Astral or equivalent) BI01010001010000000000000515BI0100001241 4 no
130 5.1 od147482/2020_2021 : 7.Supply and Installation of 50mm Dia Brass valve including Wall cutting and making good in open terrace complete as required. (Supreme/Finolex/Astral or equivalent) BI01010001010000000000000515BI0100001242 8 no
131 5.11 od147489/2020_2021 : 1.Supply and Installation of Lead free PVC-U SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.chasing the walls,floor,concrete etc. as required , replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand ). Testing of the system for leakage and Air tightness (Supreme/Finolex/Astral or equivalent) - 50mm OD 6kg/sqcm Waste Piping BI01010001010000000000000515BI0100001243 275 metre
132 5.12 od147493/2020_2021 : Supply and Installation of Lead free PVC-U SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.chasing the walls, floor, concrete etc. as required, replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand). Testing of the system for leakage and Air tightness (Supreme/Finolex/Astral or equivalent) - 75mm OD Type-B Soil Piping BI01010001010000000000000515BI0100001244 24 metre
133 5.13 od147499/2020_2021 : 11.2.Supply and Installation of Lead free PVC-U SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.chasing the walls, floor, concrete etc. as required, replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand ). Testing of the system for leakage and Air tightness (Supreme/Finolex/Astral or equivalent) - 75mm OD Type-B Waste Piping BI01010001010000000000000515BI0100001245 130 metre
134 5.14 od147504/2020_2021 : 12.4.110mm OD 6kg/sqcm Rain Water Piping BI01010001010000000000000515BI0100001246 200 metre
135 5.15 od147509/2020_2021 : 12.3.Supply and Installation of Lead free PVC-U SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings. Ts, Elbows, Bends, Ys etc. Adapters, Air vents, Clamping with GI UClamps /supports, as required for firmliy installing the pipes and adjesent to the building/ chasing the walls, concrete etc. as required , replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand ). Testing of the system for leakage and Air tightness (Supreme/Finolex/Astral or equivalent) - 110mm OD Air vent pipe BI01010001010000000000000515BI0100001247 180 metre
136 5.16 od147513/2020_2021 : 12.2. Supply and Installation of Lead free PVC-U SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings. Ts, Elbows, Bends, Ys etc.. Adapters, Air vents, Clamping with GI UClamps /supports, as required for firmliy installing the pipes and adjesent to the building/ chasing the walls, concrete etc. as required, replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand). Testing of the system for leakage and Air tightness (Supreme/Finolex/Astral or equivalent) - 110mm OD Type-B waste Piping BI01010001010000000000000515BI0100001248 260 metre
137 5.17 od147517/2020_2021 : 12.1.Supply and Installation of Lead free PVC-U SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings. Ts, Elbows, Bends, Ys etc.. Adapters, Air vents, Clamping with GI UClamps /supports, as required for firmliy installing the pipes and adjesent to the building/ chasing the walls, concrete etc. as required, replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand). Testing of the system for leakage and Air tightness (Supreme/Finolex/Astral or equivalent) - 110mm OD Type-B soil Piping BI01010001010000000000000515BI0100001249 425 metre
138 5.18 od147521/2020_2021 : Supply and Installation of Lead free UPVC SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings through trench having 60cm depth /as per site conditionand to make corresponding slope hence complete. [Excavation will be in the scope of contractor]. Testing of the system for leakage and Air tightness (Supreme/Finolex/Astral or equivalent) - 110mmOD Type-B soil piping BI01010001010000000000000515BI0100001250 200 metre
139 5.19 od147524/2020_2021 : Supply and Installation of Lead free UPVC SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings through trench having 60cm depth /as per site condition and to make corresponding slope hence complete.[Excavation will be in the scope of contractor]. Testing of the system for leakage and Air tightness (Supreme/Finolex/Astral or equivalent) - 160mmOD Type-B soil piping BI01010001010000000000000515BI0100001251 60 metre
140 5.2 od147527/2020_2021 : Supply and Installation of Lead free UPVC SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings through trench having 60cm depth /as per site conditionand to make corresponding slope hence complete.[Excavation will be in the scope of contractor]. Testing of the system for leakage and Air tightness (Supreme/Finolex/Astral or equivalent) - 200mmOD Type-B rain water piping BI01010001010000000000000515BI0100001252 170 metre
141 5.21 od147529/2020_2021 : Supply and Installation of 125x125mm CP Stainless Steel Gratings with Cockroach Protection for multi inlet floor trap. BI01010001010000000000000515BI0100001253 90 no
142 5.22 od147531/2020_2021 : Multi Inlet floor trap 110x75x50mm. BI01010001010000000000000515BI0100001254 90 no
143 5.23 od147533/2020_2021 : Supply and Installing at site Open UPVC Lead Free ASTM Schedule 40 Pipes (Equivalent Standard Size) with all accessories like bends, y's etc for Water supply Joined using Solvent Cement fittings suitable for the working pressure. Supporting exposed pipes using cement mortar at 60 cm intervals above terrace floor. Hydrostatic Testing of the Pipes using 10KG/cm2 test pressure for specified time period (Supreme/Finolex/Astral or equivalent) - 50mm Nominal Dia BI01010001010000000000000515BI0100001255 40 metre
144 5.24 od147535/2020_2021 : Supply and Installing at site Open UPVC Lead Free ASTM Schedule 40 Pipes (Equivalent Standard Size) with all accessories like bends, y's etc for Water supply Joined using Solvent Cement fittings suitable for the working pressure. Supporting exposed pipes using cement mortar at 60 cm intervals above terrace floor. Hydrostatic Testing of the Pipes using 10KG/cm2 test pressure for specified time period (Supreme/Finolex/Astral or equivalent) - 63mm Nominal Dia BI01010001010000000000000515BI0100001256 60 metre
145 5.25 od147537/2020_2021 : Supply and Installing at site Concealed UPVC ASTM Schedule 40 Pipes of Equivalent Standard Size with all accessories like bends, y's etc for Water supply Joined using Solvent Cement fittings with metal in-serts suitable for the working pressure. Chasing of the walls, concrete etc. as required, replastering and refinishing using Cement Plaster 1:3 mix [Cement : Coarse sand]. Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period (Supreme/Finolex/Astral or equivalent) - 25mm Nominal Dia BI01010001010000000000000515BI0100001257 190 metre
146 5.26 od147538/2020_2021 : Supply and Installing at site Concealed UPVC ASTM Schedule 40 Pipes of Equivalent Standard Size with all accessories like bends,y's etc for Water supply Joined using Solvent Cement fittings with metal in-serts suitable for the working pressure. Chasing of the walls, concrete etc. as required, replastering and refinishing using Cement Plaster 1:3 mix [Cement : Coarse sand]. Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period (Supreme/Finolex/Astral or equivalent) - 20mm Nominal Dia BI01010001010000000000000515BI0100001258 460 metre
147 5.27 od147540/2020_2021 : Supply and Installing at site Concealed UPVC ASTM Schedule 40 Pipes of Equivalent Standard Size with all accessories like bends, y's etc for Water supply Joined using Solvent Cement fittings with metal in-serts suitable for the working pressure. Through open walls, concrete etc. using GI clamps/supports as required, Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period (Supreme/Finolex/Astral or equivalent) - 50mm Nominal Dia BI01010001010000000000000515BI0100001259 160 metre
148 5.28 od147542/2020_2021 : Supply and Installing at site Concealed UPVC ASTM Schedule 40 Pipes of Equivalent Standard Size with all accessories like bends,y's etc for Water supply Joined using Solvent Cement fittings with metal in-serts suitable for the working pressure. Through open walls, concrete etc. using GI clamps/supports as required, Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period (Supreme/Finolex/Astral or equivalent) - 32mm Nominal Dia BI01010001010000000000000515BI0100001260 55 metre
149 5.29 od147543/2020_2021 : Supply and Installing at site Concealed UPVC ASTM Schedule 40 Pipes of Equivalent Standard Size with all accessories like bends,y's etc for Water supply Joined using Solvent Cement fittings with metal in-serts suitable for the working pressure. Through open walls, concrete etc. using GI clamps/supports as required, Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period (Supreme/Finolex/Astral or equivalent) - 25mm Nominal Dia BI01010001010000000000000515BI0100001261 35 metre
150 5.3 od147546/2020_2021 : Supply, Installing and Leveling Pipe Supports Fabricated from GI Slotted Rails / Channels of corresponding as per the site condition width suitable for carrying the operating weight of pipe and the fluids, 8mm Dia GI Adjustable Threaded Rods and Anchor Fasteners on wall, U clamps etc.as appropriate. BI01010001010000000000000515BI0100001262 400 no
151 5.31 od147548/2020_2021 : Labour charges for core cutting of slabs/beam for pipes of following sizes - 110mm dia BI01010001010000000000000515BI0100001263 108 no
152 5.32 od147550/2020_2021 : Labour charges for core cutting of slabs/beam for pipes of following sizes - 50mm dia BI01010001010000000000000515BI0100001264 26 no
153 5.33 od147552/2020_2021 : Labour charges for core cutting of slabs/beam for pipes of following sizes - 40mm dia BI01010001010000000000000515BI0100001265 15 no
154 5.34 od147553/2020_2021 : Labour charges for core cutting of slabs/beam for pipes of following sizes - 25mm dia BI01010001010000000000000515BI0100001266 8 no
155 5.35 od147556/2020_2021 : Labour charges for core cutting of slabs/beam for pipes of following sizes - 75mm dia BI01010001010000000000000515BI0100001267 4 no
156 5.36 od147557/2020_2021 : Supply and Installation of Towel Ring (Jaquar ACN-1121BN/ equivalent) BI01010001010000000000000515BI0100001268 15 no
157 5.37 od147558/2020_2021 : Supply and Installation of Towel Rod (Jaquar ACN-1111NM/ equivalent) BI01010001010000000000000515BI0100001269 50 no
158 5.38 od147559/2020_2021 : Supply and installation of rob hook (Jaquar AEC-CHR-1161/ equivalent) BI01010001010000000000000515BI0100001270 150 no
159 5.39 od147560/2020_2021 : Supply and Installation of 40mm Non-returning valves (Supreme/Finolex/Astral or equivalent) BI01010001010000000000000515BI0100001271 4 no
160 5.4 od147561/2020_2021 : Supply and Installation of 40mm Air releasing valve (Supreme/Finolex/Astral or equivalent) BI01010001010000000000000515BI0100001272 4 no
161 5.41 od147562/2020_2021 : Supply and Installation of flow switch system for water level controling (sontay/system sensor) BI01010001010000000000000515BI0100001273 2 no
162 5.42 od147563/2020_2021 : Supply and laying of 40mm nomial dia scheduled40 astm from well to tank (Supreme/Finolex/Astral or equivalent) BI01010001010000000000000515BI0100001274 110 metre
163 5.43 od147564/2020_2021 : Supply and Labour for installation of motor pump having minimum of 150 LPM discharge at 25m head including all required accessories like foot valve etc Make : 1.5HP crompton greaves/grundfos or equivalent BI01010001010000000000000515BI0100001275 4 no
164 5.44 od147565/2020_2021 : Supply and installation of uPVC LH & RH 45° junction in ground having 600 mm base, 110mm dia inlet/outlet and 160 mm dia branch inlet with riser, heavy duty CI cover, frame and all accessories (Supreme or equivalent) BI01010001010000000000000515BI0100001276 10 no
165 5.45 od147568/2020_2021 : Supply and installation of uPVC 90° / LH & RH 45° junction in ground having 315 mm base, 110mm dia inlet/outlet and 110 mm dia branch inlet with riser, heavy duty CI cover, frame and all accessories (Supreme or equivalent) BI01010001010000000000000515BI0100001277 14 no
166 6 SUMP BI01010001010000000000000515BI0100001278
167 6.01 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil BI01010001010000000000000515BI0100001279 398.821 cum
168 6.02 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size BI01010001010000000000000515BI0100001280 45.752 cum
169 6.03 od187229/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All work upto plinth level BI01010001010000000000000515BI0100001281 39.902 cum
170 6.04 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concrete BI01010001010000000000000515BI0100001282 516.53 sqm
171 6.05 5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more BI01010001010000000000000515BI0100001283 8565.4 kg
172 6.06 od147459/2020_2021 : providing and fixing cast iron manhole cover including material and labour charges complete BI01010001010000000000000515BI0100001284 960 each
173 6.07 od147465/2020_2021 : Providing glass for opening grill work BI01010001010000000000000515BI0100001285 4.41 sqm
174 6.08 10.25.1 : Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete BI01010001010000000000000515BI0100001286 129.2 kg
175 6.09 10.25.2 : Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works BI01010001010000000000000515BI0100001287 135.24 kg
176 7 SEPTIC TANK and SOAK PIT BI01010001010000000000000515BI0100001288
177 7.01 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil BI01010001010000000000000515BI0100001289 38.5 cum
178 7.02 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) BI01010001010000000000000515BI0100001290 1.3 cum
179 7.03 60.7.1 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site BI01010001010000000000000515BI0100001291 6 cum
180 7.04 5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size BI01010001010000000000000515BI0100001292 13.802 cum
181 7.05 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete BI01010001010000000000000515BI0100001293 95.651 sqm
182 7.06 5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more BI01010001010000000000000515BI0100001294 1380.2 kg
183 7.07 13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 (1 cement : 3 fine sand) BI01010001010000000000000515BI0100001295 94.741 sqm
184 7.08 23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges BI01010001010000000000000515BI0100001296 3.125 cum
185 7.09 23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge BI01010001010000000000000515BI0100001297 3.125 cum
186 7.1 23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001298 3.125 cum
187 7.11 od147470/2020_2021 : Manhole using Cast iron 60x60cm size BI01010001010000000000000515BI0100001299 480 kg
188 8 Fire Estimation BI01010001010000000000000515BI0100001300
189 8.01 od110248/2020_2021 : MS pipe 100 mm dia BI01010001010000000000000515BI0100001301 95 metre
190 8.02 od110253/2020_2021 : MS pipe 80 mm dia BI01010001010000000000000515BI0100001302 81 metre
191 8.03 od110254/2020_2021 : MS pipe 65 mm dia BI01010001010000000000000515BI0100001303 47 metre
192 8.04 od110258/2020_2021 : MS pipe 50 mm dia BI01010001010000000000000515BI0100001304 18 metre
193 8.05 od110264/2020_2021 : MS pipe 40 mm dia BI01010001010000000000000515BI0100001305 79 metre
194 8.06 od110266/2020_2021 : MS pipe 32 mm dia 1 m /31.1kg/m BI01010001010000000000000515BI0100001306 124 metre
195 8.07 od110300/2020_2021 : MS pipe 32 mm dia 1 m /2.41kg/m BI01010001010000000000000515BI0100001307 435 metre
196 8.08 od110353/2020_2021 : Under ground piping -100mm dia BI01010001010000000000000515BI0100001308 30 metre
197 8.09 od110377/2020_2021 : Hydraulic Hose Reel drum BI01010001010000000000000515BI0100001309 8 each
198 8.1 od110452/2020_2021 : Ball valve BI01010001010000000000000515BI0100001310 8 each
199 8.11 od110465/2020_2021 : GM Single Headed Hydrant Valve 63 mm dia BI01010001010000000000000515BI0100001311 8 each
200 8.12 od110481/2020_2021 : Single Door Hose Cabinet BI01010001010000000000000515BI0100001312 8 each
201 8.13 od110493/2020_2021 : GM Branch pipe, ISI marked 63 mm Female Instantaneous inlet BI01010001010000000000000515BI0100001313 8 each
202 8.14 od110500/2020_2021 : Controlled Percolated Hose Conforming to IS: 636, 63 mm dia 15 mtrs. BI01010001010000000000000515BI0100001314 8 each
203 8.15 od110532/2020_2021 : Single Acting Release valve with screwed inlet 20 mm dia BI01010001010000000000000515BI0100001315 2 each
204 8.16 od110544/2020_2021 : Fire Brigade with inlet connection with 3 Nos of 63 mm dia. BI01010001010000000000000515BI0100001316 1 each
205 8.17 od110551/2020_2021 : Electrically Driven Mono Block Terrace pump of capacity 900 LPM BI01010001010000000000000515BI0100001317 1 each
206 8.18 od110560/2020_2021 : Electrically Driven Mono Block pump of capacity 2280 LPM BI01010001010000000000000515BI0100001318 1 each
207 8.19 od110579/2020_2021 : Electrically Driven Mono Block pump of capacity 180 LPM BI01010001010000000000000515BI0100001319 1 each
208 8.2 od110590/2020_2021 : Diesel operated Mono block pump of capacity 2280 LPM BI01010001010000000000000515BI0100001320 1 each
209 8.21 od110726/2020_2021 : Pressure Gauge BI01010001010000000000000515BI0100001321 1 each
210 8.22 od110732/2020_2021 : CI Butterfly valve slim seal standard lever operates type 100 mm dia BI01010001010000000000000515BI0100001322 12 each
211 8.23 od110743/2020_2021 : CI Butterfly valve slim seal standard lever operates type 80 mm dia BI01010001010000000000000515BI0100001323 8 each
212 8.24 od110750/2020_2021 : CI Non Return Valve slim seal type with required flanges BI01010001010000000000000515BI0100001324 6 each
213 8.25 od110773/2020_2021 : Sprinkled heads designed to operate at 68 deg celcious ets BI01010001010000000000000515BI0100001325 304 each
214 8.26 od110799/2020_2021 : Sign boards made out of 3 mm thick "Opaque" PVC foam board with computer cut BI01010001010000000000000515BI0100001326 12 each
215 8.27 od110843/2020_2021 : Indoor type Exit board with LED Lamps reflector indicating arrows with exit recess mounted type BI01010001010000000000000515BI0100001327 8 each
216 8.28 od110850/2020_2021 : Manuel call point break glass type BI01010001010000000000000515BI0100001328 8 each
217 8.29 od110860/2020_2021 : Electronic dual tone Hooter BI01010001010000000000000515BI0100001329 8 each
218 8.3 od110863/2020_2021 : Main Fire alarm control panel of 4 Zones capacity with visual Led indication for fire BI01010001010000000000000515BI0100001330 1 each
219 8.31 od110869/2020_2021 : PVC conduit 20 mm dia BI01010001010000000000000515BI0100001331 187 metre
220 8.32 od110883/2020_2021 : 1 sq.mm Cross section PVC insulated copper wires BI01010001010000000000000515BI0100001332 364 metre
221 8.33 od110886/2020_2021 : Fire Extinguishers BI01010001010000000000000515BI0100001333 8 no
222 9 ELECTRICAL ESTIMATE BI01010001010000000000000515BI0100001334
223 9.01 90.12.7.12 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3 core 4 sq mm with factory made clamp. BI01010001010000000000000515BI0100001335 95 metre
224 9.02 90.12.7.28 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 35 sq mm with factory made clamp BI01010001010000000000000515BI0100001336 75 metre
225 9.03 90.12.7.29 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 50 sq mm with factory made clamp BI01010001010000000000000515BI0100001337 120 metre
226 9.04 90.12.7.31 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 95 sq mm. BI01010001010000000000000515BI0100001338 20 metre
227 9.05 90.12.7.38 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 4 sq mm with factory made clamp BI01010001010000000000000515BI0100001339 40 metre
228 9.06 90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 10 sq mm with factory made clamp BI01010001010000000000000515BI0100001340 135 metre
229 9.07 90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 16 sq mm with factory made clamp BI01010001010000000000000515BI0100001341 75 metre
230 9.08 90.12.7.42 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 25 sq mm with factory made clamp BI01010001010000000000000515BI0100001342 65 metre
231 9.09 9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 10 sq. mm (25mm) BI01010001010000000000000515BI0100001343 12 set
232 9.1 9.2.18 : Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 35 sq. mm BI01010001010000000000000515BI0100001344 2 each
233 9.11 9.2.19 : Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm BI01010001010000000000000515BI0100001345 4 each
234 9.12 9.2.21 : Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 95 sq. mm BI01010001010000000000000515BI0100001346 4 each
235 9.13 9.2.29 : Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm BI01010001010000000000000515BI0100001347 12 each
236 9.14 9.2.30 : Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm BI01010001010000000000000515BI0100001348 4 each
237 9.15 5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required BI01010001010000000000000515BI0100001349 12 set
238 9.16 5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) BI01010001010000000000000515BI0100001350 155 metre
239 9.17 1.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC\ninsulated copper conductor single core cable in surface / recessed medium class PVC conduit,\nwith modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS\nPVC insulated copper conductor single core cable etc as required.Group B BI01010001010000000000000515BI0100001351 330 point
240 9.18 1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. BI01010001010000000000000515BI0100001352 30 point
241 9.19 1.17.9 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm BI01010001010000000000000515BI0100001353 45 metre
242 9.2 1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm BI01010001010000000000000515BI0100001354 250 metre
243 9.21 1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire BI01010001010000000000000515BI0100001355 4000 metre
244 9.22 1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire BI01010001010000000000000515BI0100001356 1200 metre
245 9.23 1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire BI01010001010000000000000515BI0100001357 400 metre
246 9.24 4.1.14 : Supplying and installing following size of perforated pre-painted M.S. cable trays with\nperforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 75 mm depth X 2.0 mm thickness BI01010001010000000000000515BI0100001358 395 metre
247 9.25 4.2.13 : Supplying and installing following size of perforated pre-painted M.S. cable trays bends with\nperforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.900 mm width X 62.5 mm depth X 2.0 mm thickness BI01010001010000000000000515BI0100001359 25 no
248 9.26 2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door BI01010001010000000000000515BI0100001360 4 each
249 9.27 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole BI01010001010000000000000515BI0100001361 164 each
250 9.28 2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole BI01010001010000000000000515BI0100001362 10 each
251 9.29 2.12.2 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps BI01010001010000000000000515BI0100001363 1 each
252 9.3 2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps BI01010001010000000000000515BI0100001364 3 each
253 9.31 2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps BI01010001010000000000000515BI0100001365 4 each
254 9.32 1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings). BI01010001010000000000000515BI0100001366 63 each
255 9.33 1.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. BI01010001010000000000000515BI0100001367 30 each
256 9.34 1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). BI01010001010000000000000515BI0100001368 88 each
257 9.35 od115309/2020_2021 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator), 6 way (4+18), Double door BI01010001010000000000000515BI0100001369 2 each
258 9.36 od115357/2020_2021 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4+12), Double door BI01010001010000000000000515BI0100001370 6 each
259 9.37 od115886/2020_2021 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But with out MCB/RCCB/Isolator), 4 way (4+12), Double door BI01010001010000000000000515BI0100001371 6 each
260 9.38 2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps BI01010001010000000000000515BI0100001372 2 each
261 9.39 od161561/2020_2021 : "MSB WITH METERING" Supply, Installation, Testing and commissioning of 125 A MV Cubicle panel board. front opening type, wall mounted free standing on 3" MS channel directly bolted to wall using nuts and bolts stenciling all identification etc.. confirming to IS1863, IE rules. Incomer 125A TP 36kA MCCB variable setting with inbuit EF release - 1 No. Class B&C Surge arrestor Type 1, Type 2 Outgoings 100A TP 25ka MCCB with all isolation duty and 3 Nos.125A cut out fuse unit and provision for CT net metering -1nos. 63A TPN 25ka MCCB with all isolation duty and 3 Nos.63A cut out fuse unit and provision for KWH meter-1nos. 63A 4P ACCL without Current limiter. All MCCBs are with rotary operating handle for door interlock. Busbar :125A TPN Al busbar BI01010001010000000000000515BI0100001373 1 each
262 9.4 od161562/2020_2021 : "LCP Supply, Installation, Testing and commissioning of 40A MV Cubicle panel. Fabricated out of 16 swg CR CA sheet, powder coated dust and vermin tight proof, front opening type, flush and floor mounted free standing on 3" MS channel directly bolted to floor using nuts and bolts stenciling all identification etc.. confirming to IS1863, IE rules; INCOMER: 40A TPN MCB isolator - 1NOS; RYB Pilolet lamp - 1NOS; OUTGOING: 40A 4P 30MA RCCB - 1NOS; 25A DP 30MA RCCB with 4nos of 6A SP MCB - 1nos; Busbar: 40A TPN Al busbar" BI01010001010000000000000515BI0100001374 1 each
263 9.41 od161564/2020_2021 : "SSB Supply, Installation, Testing and commissioning of 100A MV Cubicle panel. Fabricated out of 16 swg CR CA sheet, powder coated dust and vermin tight proof, front opening type, flush and floor mounted free standing on 3" MS channel directly bolted to floor using nuts and bolts stenciling all identification etc.. confirming to IS1863, IE rules; Incomer:100A TPN ISO - 1Nos.; 100A TPN ISO - 1Nos.; 100A 4P AC-1 Duty Contactor - 2Nos; RYB Piolet Lamps-2Set; Multifunction Meter-1No.; Outgoings 63A TP 18KA MCCB - 6 Nos; 40A TP 18KA MCCB - 3 Nos.; 80A TPN MCCB-1Nos [solar]; 63A 4P Isolator-1Nos; Electrical and mechanical interlocking shall be done. Microprocessor based AMF relay; All MCCBs are with rotary operating handle for door interlock. Busbar :100A TPN Al busbar" BI01010001010000000000000515BI0100001375 1 each
264 9.42 2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps BI01010001010000000000000515BI0100001376 6 each
265 9.43 1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. BI01010001010000000000000515BI0100001377 100 each
266 9.44 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch BI01010001010000000000000515BI0100001378 26 each
267 9.45 1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet BI01010001010000000000000515BI0100001379 26 each
268 9.46 1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet BI01010001010000000000000515BI0100001380 50 each
269 9.47 90.16.3.8 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required (for horizontal run) 20 x 3 mm copper strip BI01010001010000000000000515BI0100001381 334 metre
270 9.48 90.16.4.7 : Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required (for vertical run). 20 x 3 mm copper strip BI01010001010000000000000515BI0100001382 141 metre
271 9.49 90.16.1.5 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required. 75mm copper conductor (6 SWG) BI01010001010000000000000515BI0100001383 125 metre
272 9.5 od162126/2020_2021 : Supply and Fixing of laminated schematic drawings. BI01010001010000000000000515BI0100001384 1 each
273 9.51 od162127/2020_2021 : Supply and Fixing of 2Nos. 9 litres red colour fire bucket on stands BI01010001010000000000000515BI0100001385 2 each
274 9.52 od162128/2020_2021 : Supply and Fixing of 5kg dry powder fire extinguishers on clamp. BI01010001010000000000000515BI0100001386 2 each
275 9.53 od162129/2020_2021 : supply and fixing of 440 V grade synthetic insulated mat 2 meter x 1 meter x 6mm conforming to IS:15652:2006 BI01010001010000000000000515BI0100001387 4 each
276 9.54 od162130/2020_2021 : Supply and fixing of shock treatment chart in glass with frame BI01010001010000000000000515BI0100001388 1 each
277 9.55 od162131/2020_2021 : Supply and fixing of LT danger boards BI01010001010000000000000515BI0100001389 1 each
278 9.56 od162274/2020_2021 : "GSB; Supply, Installation, Testing and commissioning of 125A MV Cubicle panel. Fabricated out of 16 swg CR CA sheet, powder coated dust and vermin tight proof, front opening type, flush and floor mounted free standing on 3" MS channel directly bolted to floor using nuts and bolts stenciling all identification etc.. confirming to IS1863, IE rules; Incomer 125A TPN isolator - 1nos; RYB piolet lamp - 1nos; Reverse Power Relay 415V AC -1nos; Outgoing100A TPN 25KA MCCB - 1 nos; 63A TPN 25KA MCCB -1No; All MCCBs are with rotary operating handle for door interlock; Busbar:125A TPN Al busbar BI01010001010000000000000515BI0100001390 1 each
279 9.57 1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) BI01010001010000000000000515BI0100001391 74 each
280 9.58 od162345/2020_2021 : Supply and fixing of DOL starter for 1.5Hp in open enclosure with required capacitor with on/off push button BI01010001010000000000000515BI0100001392 4 each
281 9.59 od162346/2020_2021 : Supply and installation of IP-65 junction box suitable for connecting 3x2.5 sqmm cu cable BI01010001010000000000000515BI0100001393 15 each
282 9.6 od162347/2020_2021 : Supply and installation of 63A 4P cubical isolator with open enclosure IP based<br> BI01010001010000000000000515BI0100001394 4 each
283 9.61 od162348/2020_2021 : Supply and Installation of V25 B+C/3+NPE 320V BI01010001010000000000000515BI0100001395 5 each
284 9.62 od162349/2020_2021 : Supply and installation of RJ 45 socket With Shutter BI01010001010000000000000515BI0100001396 74 each
285 9.63 14.4 : Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres. BI01010001010000000000000515BI0100001397 54 cum
286 9.64 14.9 : Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required. BI01010001010000000000000515BI0100001398 5 cum
287 9.65 14.11 : Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels. BI01010001010000000000000515BI0100001399 40 cum
288 9.66 od162549/2020_2021 : Supply and labour charges for Fixing of 40W post top light with 3mtr pole BI01010001010000000000000515BI0100001400 15 each
289 9.67 od162550/2020_2021 : Supply and labour charges for Fixing of 20w tube light 1200mm BI01010001010000000000000515BI0100001401 14 each
290 9.68 od162551/2020_2021 : Supply and labour charges for Fixing of Mirror Light 10W 2feet battern light BI01010001010000000000000515BI0100001402 28 each
291 9.69 od162552/2020_2021 : Supply and labour charges for Fixing of Ceiling exhaust fan 28w ceiling mounting white vent air sweep 130 mm BI01010001010000000000000515BI0100001403 27 each
292 9.7 od162553/2020_2021 : Supply and labour charges for Fixing of Wall Fan 60W 450mm sweep BI01010001010000000000000515BI0100001404 10 each
293 9.71 od162554/2020_2021 : Supply and labour charges for Fixing of Wall Exhaust Fan 9 Inch BI01010001010000000000000515BI0100001405 27 each
294 9.72 od162555/2020_2021 : Supply and labour charges for Fixing of Ceiling fan 1200 mm BI01010001010000000000000515BI0100001406 100 each
295 9.73 od162556/2020_2021 : Supply and labour charges for Fixing of 9w Square LED Panel Ceiling Light BI01010001010000000000000515BI0100001407 421 each
296 9.74 od162557/2020_2021 : Supply and labour charges for Fixing of 12W Round LED Panel Ceiling Light BI01010001010000000000000515BI0100001408 18 each
297 9.75 od162558/2020_2021 : Supply and labour charges for Fixing of 18w Round LED Panel Ceiling Light BI01010001010000000000000515BI0100001409 52 each
298 9.76 od162559/2020_2021 : Supply and labour charges for Fixing of 6W Round LED Panel Ceiling Light BI01010001010000000000000515BI0100001410 66 each
299 9.77 od162561/2020_2021 : Supply and labour charges for Fixing of 18W Exterior Wall light - Bulk Head BI01010001010000000000000515BI0100001411 10 each
300 9.78 od162562/2020_2021 : Supply and labour charges for Fixing of 12w Wall light(wall washer) BI01010001010000000000000515BI0100001412 10 each
301 9.79 6.3 : Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. BI01010001010000000000000515BI0100001413 2 each
302 9.8 od162574/2020_2021 : Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, copper tube,having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc.complete as required. BI01010001010000000000000515BI0100001414 2 each
303 9.81 od162662/2020_2021 : Preparation of necessary drawing and getting all necessary approvals/sanction, inspection,supervision charges etc.from EI/EB including all sundries expenses except statutory charges. Statutory charges shall be reimbursed only after producing valid proof BI01010001010000000000000515BI0100001415 1 L.S
304 9.82 od162663/2020_2021 : Supply and labour charges for Fixing of 12W T bulb with holder BI01010001010000000000000515BI0100001416 10 each
305 9.83 8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm BI01010001010000000000000515BI0100001417 100 metre
306 9.84 10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm BI01010001010000000000000515BI0100001418 2 each
307 9.85 od190007/2020_2021 : Supply of following 11 KV XLPE UG cable in existing open trench/ open tray 3cx300sq mm BI01010001010000000000000515BI0100001419 100 metre
308 10 AC ESTIMATE BI01010001010000000000000515BI0100001420
309 10.01 od116004/2020_2021 : Supply, Installation, Testing & Commissioining of Armoured control cum transmission wiring between ODU & IDU of required size with pvc conduit and other accessories as per specification and relavent standards, and all other electrical connections from isolator to the units BI01010001010000000000000515BI0100001421 280 metre
310 10.02 od116043/2020_2021 : Condensate Piping Supply and erection of the condensate UPVC pipes with all joints, reducers, necessary elbows and tees, supporting arrangements etc. Rate shall inclusive of thermal insulation with 13mm thickness FM approved closed cell nitrile rubber insulation covering with fire resistant fibre cloth fabric as a resistant to scracth and mechanical impacts 25mm Dia UPVC BI01010001010000000000000515BI0100001422 230 metre
311 10.03 od116051/2020_2021 : Supply and labour for installation of Refnut Y joints BI01010001010000000000000515BI0100001423 10 each
312 10.04 od116146/2020_2021 : Supply and labour for Refrigerant gas charging R410 gas BI01010001010000000000000515BI0100001424 30 kg
313 10.05 od116305/2020_2021 : "Refrigerant Piping- Supply and errection of 16gauge hard drawn refrigerant copper pipe to integrate out door/ indoor units. The rate shall inclusive of closed cell nitrile rubber insulation for copper pipes and fiber glass cloth covering. The FRP/poly shield coating shall be applied over the insulation for exposed application. Pipe size and insulation thickness as follows" 9.5mm with 6.35mm thick insulation BI01010001010000000000000515BI0100001425 6 metre
314 10.06 od116312/2020_2021 : "Refrigerant Piping- Supply and errection of 16gauge hard drawn refrigerant copper pipe to integrate out door/ indoor units. The rate shall inclusive of closed cell nitrile rubber insulation for copper pipes and fiber glass cloth covering. The FRP/poly shield coating shall be applied over the insulation for exposed application. Pipe size and insulation thickness as follows" 12.7 mm with 6.35 mm thick insulation BI01010001010000000000000515BI0100001426 58 metre
315 10.07 od116329/2020_2021 : "Refrigerant Piping- Supply and errection of 16gauge hard drawn refrigerant copper pipe to integrate out door/ indoor units. The rate shall inclusive of closed cell nitrile rubber insulation for copper pipes and fiber glass cloth covering. The FRP/poly shield coating shall be applied over the insulation for exposed application. Pipe size and insulation thickness as follows" 15.9mm with 9.5mm thick insulation BI01010001010000000000000515BI0100001427 25 metre
316 10.08 od116342/2020_2021 : "Refrigerant Piping- Supply and errection of 16gauge hard drawn refrigerant copper pipe to integrate out door/ indoor units. The rate shall inclusive of closed cell nitrile rubber insulation for copper pipes and fiber glass cloth covering. The FRP/poly shield coating shall be applied over the insulation for exposed application. Pipe size and insulation thickness as follows" 19.1mm with 9.5 mm thick insulation BI01010001010000000000000515BI0100001428 65 metre
317 10.09 od116374/2020_2021 : "Refrigerant Piping- Supply and errection of 16gauge hard drawn refrigerant copper pipe to integrate out door/ indoor units. The rate shall inclusive of closed cell nitrile rubber insulation for copper pipes and fiber glass cloth covering. The FRP/poly shield coating shall be applied over the insulation for exposed application. Pipe size and insulation thickness as follows" 28.6 mm with 12.7 mm thick insulation BI01010001010000000000000515BI0100001429 70 metre
318 10.1 od116379/2020_2021 : "Refrigerant Piping - Supply and errection of 16gauge hard drawn refrigerant copper pipe to integrate out door/ indoor units. The rate shall inclusive of closed cell nitrile rubber insulation for copper pipes and fiber glass cloth covering. The FRP/poly shield coating shall be applied over the insulation for exposed application. Pipe size and insulation thickness as follows" 22.2 mm with 9.5 mm thick insulation BI01010001010000000000000515BI0100001430 6 metre
319 10.11 od116384/2020_2021 : "OUT DOOR UNITS Supply, Installation, testing and commissioning of out door units consist of 100% inverter scroll compressor/twin rotary compressors, Dc fan Motor with aero-spiral fan blade, e-pass heat exchangers, safety valves, solenoid valves, receiver, capillary tubes, check valve, electronic expansion valve, High pressure switch, low pressure sensor, pressure regulating valve, refrigerant filter, stop valve, accumulator and refnet kits. Rate inclusive of R-410A refrigerant and oil pre charging, power cable from nearest isolator, vibration isolators, supports, necessary foundation/ pedestal works etc..(High COP Models)" 14HP BI01010001010000000000000515BI0100001431 2 each
320 10.12 od116389/2020_2021 : "INDOOR UNITS Design, Supply, Installation, testing and Commissioning of VRF indoor air conditioning units with direct driven fan, high efficient filter, Inbulit micro controller thermostat, electronic expansion valve, Remote controller including cables, neccessory supports and vibratrion isolators, Refrigerant charging, refnet joints for both liquid and gas lines branch kits, control wiring, power cables form nearest socket including plug, drain connections etc.. Capacities as mensioned below" FOUR-WAY CASSETTE AC(VRF) a) Cooling capacity-3TR BI01010001010000000000000515BI0100001432 4 each
321 10.13 od116392/2020_2021 : "INDOOR UNITS Design, Supply, Installation, testing and Commissioning of VRF indoor air conditioning units with direct driven fan, high efficient filter, Inbulit micro controller thermostat, electronic expansion valve, Remote controller including cables, neccessory supports and vibratrion isolators, Refrigerant charging, refnet joints for both liquid and gas lines branch kits, control wiring, power cables form nearest socket including plug, drain connections etc.. Capacities as mensioned below" HI-WALL SPLIT AC(VRF) d) Cooling capacity-0.8TR BI01010001010000000000000515BI0100001433 1 each
322 10.14 od116445/2020_2021 : "INDOOR UNITS Design, Supply, Installation, testing and Commissioning of VRF indoor air conditioning units with direct driven fan, high efficient filter, Inbulit micro controller thermostat, electronic expansion valve, Remote controller including cables, neccessory supports and vibratrion isolators, Refrigerant charging, refnet joints for both liquid and gas lines branch kits, control wiring, power cables form nearest socket including plug, drain connections etc.. Capacities as mensioned below" HI-WALL SPLIT AC(VRF) c) Cooling capacity-1.5TR BI01010001010000000000000515BI0100001434 6 each
323 10.15 od116450/2020_2021 : "INDOOR UNITS Design, Supply, Installation, testing and Commissioning of VRF indoor air conditioning units with direct driven fan, high efficient filter, Inbulit micro controller thermostat, electronic expansion valve, Remote controller including cables, neccessory supports and vibratrion isolators, Refrigerant charging, refnet joints for both liquid and gas lines branch kits, control wiring, power cables form nearest socket including plug, drain connections etc.. Capacities as mensioned below" HI-WALL SPLIT AC(VRF) b)Cooling capacity-2TR BI01010001010000000000000515BI0100001435 1 each
324 10.16 od116452/2020_2021 : "INDOOR UNITS Design, Supply, Installation, testing and Commissioning of VRF indoor air conditioning units with direct driven fan, high efficient filter, Inbulit micro controller thermostat, electronic expansion valve, Remote controller including cables, neccessory supports and vibratrion isolators, Refrigerant charging, refnet joints for both liquid and gas lines branch kits, control wiring, power cables form nearest socket including plug, drain connections etc.. Capacities as mensioned below" HI-WALL SPLIT AC(VRF) a) Cooling capacity-2.5TR BI01010001010000000000000515BI0100001436 2 each
325 11 DIESEL GENERATOR BI01010001010000000000000515BI0100001437
326 11.01 od162195/2020_2021 : Supply and Labour charges for erection of additional length of MS[B class medium grade]exhaust pipe line of suitable sizes, with heat resistant Al painting to building top for 82.5 KVA DG. BI01010001010000000000000515BI0100001438 20 metre
327 11.02 od162196/2020_2021 : "Diesel generator; Supply and Labour for Installation, testing & commissioning of 3 phase 82.5 KVA Diesel generator, including required earthing, power/control cabling, terminations including getting the necessary clearance/approval of generator from electrical inspectorate, testing of neutral CT, relays, meters etc.. as required[statutory charges shall be borne by the clients on production of valid proof][ Mechanical erection of packaged generator will be done by the generator supplier]" BI01010001010000000000000515BI0100001439 1 each
328 12 UPS BI01010001010000000000000515BI0100001440
329 12.01 od162234/2020_2021 : "UPS; Supply and Labour for installation of 3 phase in single phase out 20kVA UPS with battery bank SMF type having 20 minutes back up" BI01010001010000000000000515BI0100001441 1 each
330 13 LIFT BI01010001010000000000000515BI0100001442
331 13.11 One lift passenger MRL 8 passenger 544 kgs of V3f Gearless with Automatic centre opening doors in stainless steel hairline finish upto 5 stops without machine room BI01010001010000000000000515BI0100001443 1 each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail