Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ramanattukara → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Ramanattukara Municipal Office Building - Retender Building Including Civil , Plumbing , Electrical Works , Etc

BOQ

Work Name : Construction of Office Building for Ramanattukara Municipality
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11NEW OFFICE BUILDING - CIVILBI01010001010000000000000515BI0100001113
21.012.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area clearedBI01010001010000000000000515BI01000011141836sqm
31.02od197044/2020_2021 : Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by rolling with power roller of minimum 8 tonnes, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.BI01010001010000000000000515BI01000011153900.1cum
41.032.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soilBI01010001010000000000000515BI0100001116107.052cum
51.044.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)BI01010001010000000000000515BI0100001117110.346cum
61.05od187229/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. All work upto plinth levelBI01010001010000000000000515BI0100001118145.996cum
71.06od187257/2020_2021 : Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/RMC.BI01010001010000000000000515BI01000011191150.83cum
81.07od187280/2020_2021 : Extra for providing richer mixes at all floor levels. Providing M-35 grade concrete instead of M-25 grade BMC/RMC.BI01010001010000000000000515BI0100001120711.294cum
91.08od187300/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. All work above plinth level upto floor V levelBI01010001010000000000000515BI01000011211055.39cum
101.095.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantileversBI01010001010000000000000515BI01000011223819.66sqm
111.15.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and StrutsBI01010001010000000000000515BI01000011231419.96sqm
121.115.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platformBI01010001010000000000000515BI01000011243719.05sqm
131.125.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)BI01010001010000000000000515BI0100001125214.377sqm
141.135.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concreteBI01010001010000000000000515BI0100001126316.051sqm
151.1420.2.4 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).500 mm dia pilesBI01010001010000000000000515BI0100001127837metre
161.1520.2.5 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).600 mm dia pilesBI01010001010000000000000515BI01000011281026metre
171.16od184175/2020_2021 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap). 700 mm dia pilesBI01010001010000000000000515BI0100001129540metre
181.17od197057/2020_2021 : Boring by mechanical means including diamond core cutting in hard rock for pile socketing, including getting out the excavated material and disposal of surplus excavated material as directed, within a lead of 50 m. (For 500mm, 600mm, 700mm piles)BI01010001010000000000000515BI010000113050.5metre
191.18od199665/2020_2021 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single pile above 50 tonne and upto 200 tonne capacity Initial testBI01010001010000000000000515BI01000011313per test
201.19od199672/2020_2021 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single pile above 50 tonne and upto 200 tonne capacity Routine testBI01010001010000000000000515BI01000011323per test
211.215.2.1 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)BI01010001010000000000000515BI010000113314.511cum
221.215.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or moreBI01010001010000000000000515BI0100001134228792kg
231.2250.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 (1 cement: 6 coarse sand) etc complete.BI01010001010000000000000515BI0100001135397.04cum
241.2350.6.1.3 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM 1:6 (1 cement :6 coarse sand) etc completeBI01010001010000000000000515BI0100001136383.911cum
251.246.27.2 : Brick work with common burnt clay modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand). Above plinth level and upto floor V levelBI01010001010000000000000515BI0100001137129.186cum
261.25od149727/2020_2021 : Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:6 (1 cement : 6 coarse sand)BI01010001010000000000000515BI010000113854.958sqm
271.2613.1.1 : 12 mm cement plaster of mix:1:4 (1 cement : 4 fine sand)BI01010001010000000000000515BI01000011399217.99sqm
281.2713.16.1 : 6 mm cement plaster of mix:1:3 (1 cement : 3 fine sand)BI01010001010000000000000515BI01000011405158.72sqm
291.28od147534/2020_2021 : Providing and laying LEPPATO FINISHED Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Architect.BI01010001010000000000000515BI0100001141344.079sqm
301.29od147536/2020_2021 : Labour for fixing, edge rounding and final polishing of Granite edges for steps an etcBI01010001010000000000000515BI0100001142792.401metre
311.38.13.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as\nper the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with\ncement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as\nspecified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent.BI01010001010000000000000515BI0100001143706.114sqm
321.31od197193/2020_2021 : Providing and laying full body vitrified matt floor tiles in different sizes (10-15mm thickness) with water absorption less than 0.08% and conforming to IS : 15622, of approved make like Johnson/ Kajaria/ Rak/ Nitco/ Equivalent with a basic price of not less than Rs.1100/sqm in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm.BI01010001010000000000000515BI01000011441990.16sqm
331.32od197195/2020_2021 : Providing and laying full body Vitrified matt tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make like Johnson/ Kajaria/ Rak/ Nitco/ equivalent with a basic price not less than Rs.1100/sqm, in all colours & shade, in skirting, recessed into wall, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mmBI01010001010000000000000515BI0100001145213.199sqm
341.33od197197/2020_2021 : Providing and laying full body vitrified matt floor tiles in different sizes (10-15mm thickness) with water absorption less than 0.08% and conforming to IS : 15622, of approved make like Johnson/ Kajaria/ Rak/ Nitco/ Equivalent with a basic price of not less than Rs.1500/sqm in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mmBI01010001010000000000000515BI0100001146273.388sqm
351.34od197201/2020_2021 : Providing and laying full body Vitrified matt tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make like Johnson/ Kajaria/ Rak/ Nitco/ equivalent with a basic price not less than Rs.1350/sqm, in all colours & shade, in skirting, recessed into wall, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mmBI01010001010000000000000515BI010000114714.497sqm
361.35od197203/2020_2021 : Providing and laying full body vitrified matt floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make like Johnson/ Kajaria/ Rak/ Nitco/ Equivalent with a basic price of not less than Rs.680/sqm in all colours and shades except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm.BI01010001010000000000000515BI0100001148251.528sqm
371.36od197204/2020_2021 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make like Johnson/ Kajaria/ Rak/ Nitco/ equivalent with a basic price not less than Rs.300/sqm, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.BI01010001010000000000000515BI0100001149914.206sqm
381.37od197206/2020_2021 : Providing and laying matt finished heavy duty vitrified tile of size 450x450x12mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make like Johnson/ Kajaria/ equivalent with a basic price not less than Rs.645/sqm in all colours and shades in for outdoor floors such as court yard etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.BI01010001010000000000000515BI0100001150121.68sqm
391.38od183310/2020_2021 : Providing and paving baby chips around the buildingBI01010001010000000000000515BI0100001151128sqm
401.39od147554/2020_2021 : Providing and fixing of 15cm height platform making with 16mm marine plywood IS710.Grd top panel placed on proper reinforced double thick same grade plywood structuresBI01010001010000000000000515BI010000115269.92sqm
411.42.35.3.1 : Diluting and injecting chemical emulsion for POST -CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentrationBI01010001010000000000000515BI01000011531092.83sqm
421.41od197207/2020_2021 : Providing and laying semi polished, flamed Cerastone or equivalent (4inch thick) of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, with Buffalo grass in the gap of 2cm including all labour, material, etc. all complete as per the direction of Engineer-in-charge.BI01010001010000000000000515BI01000011541420sqm
431.428.2.1.1 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Raj Nagar Plain white marble/ Udaipur green marble/Zebra black marbleArea of slab upto 0.50 sqmBI01010001010000000000000515BI0100001155112.369sqm
441.4313.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.BI01010001010000000000000515BI01000011569217.99sqm
451.4413.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)BI01010001010000000000000515BI01000011574140.55sqm
461.4513.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqmBI01010001010000000000000515BI01000011586382.02sqm
471.4612.20 : Providing and laying pressed clay tiles ( as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat completeBI01010001010000000000000515BI0100001159111.671sqm
481.479.117.1 : Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mmBI01010001010000000000000515BI0100001160653.35metre
491.489.118.2 : Providing and fixing to existing door frames30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge.BI01010001010000000000000515BI0100001161237.705sqm
501.49od197208/2020_2021 : Providing and fixing factory made uPVC white colour casement / casement cum fixed louvre window uPVC frame along with louvres. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge.BI01010001010000000000000515BI01000011621.2sqm
511.5od194725/2020_2021 : Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door with 6mm thick toughened glass comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.BI01010001010000000000000515BI010000116315.18sqm
521.51od197219/2020_2021 : Providing and fixing factory made uPVC white colour sliding glazed door with 6mm toughened glass comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm)BI01010001010000000000000515BI010000116412.54sqm
531.529.147A.1 : Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required\nlength (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and\nnecessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance\nin dimension i.e. in depth & width of profile shall be acceptable.Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 +/- 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.)BI01010001010000000000000515BI01000011659.96sqm
541.539.147A.3 : Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required\nlength (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and\nnecessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance\nin dimension i.e. in depth & width of profile shall be acceptable. Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazingbead of appropriate dimension. ( Area of window upto 2.50 sqm).BI01010001010000000000000515BI0100001166267.283sqm
551.549.147B.1 : 543 SUB HEAD : 9 - WOOD & PVC WORK\n9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized\nmild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and\nsilicon sealant shall be paid separately).\nNote: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)BI01010001010000000000000515BI010000116747.386sqm
561.55od147566/2020_2021 : Providing and fixing in position wall panelling at all heights with Saint gobain approved by the Architect, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be in-serted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer's specification as per direction of Engineer-in-Charge all complete. With 15 mm thick fully perforated square/butt edge light weight calcium silicatepanels/ tilesBI01010001010000000000000515BI0100001168522.789sqm
571.56od178886/2020_2021 : Providing and fixing Fibre (high impact poly propelene reinforced) cement sheet of good quality in all colours with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete:BI01010001010000000000000515BI0100001169113.81sqm
581.57od147569/2020_2021 : Providing & fixing false ceiling at all heights with with 40mm thick Alfaa sandwich panel grey coloured be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.BI01010001010000000000000515BI0100001170500.514sqm
591.5810.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.BI01010001010000000000000515BI010000117110767.8kg
601.5913.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new workBI01010001010000000000000515BI0100001172534.101sqm
611.6od147570/2020_2021 : Providing & fixing on decorativetile paving of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)BI01010001010000000000000515BI010000117396.382sqm
621.61od194803/2020_2021: Providing at all heights, levels and locations powder coated Aluminium trafford sheet 0.50mm thick (Jindal/ Oralium/ Hindalco/ Everlast/ Equivalent). The sheet shall be fixed using self drilling/self tapping SS screws of size 5.5x65 mm with EPDM seal complete upto required pitch in horizontal, vertical or curved surfaces i/c cutting to size and shape whereever required as per specifications, detail drawings and direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealent wherever required etc. but excluding the cost of purlins, rafters and trusses.BI01010001010000000000000515BI0100001174468.752sqm
631.62od194805/2020_2021 : Providing at all heights, levels and locations powder coated Aluminium Corrugated sheet 0.46mm thick (Jindal/ Oralium/ Hindalco/ Everlast/ Equivalent). The sheet shall be fixed using self drilling/ self tapping SS screws of size 5.5x65 mm with EPDM seal complete upto required pitch in horizontal, vertical or curved surfaces i/c cutting to size and shape whereever required as per specifications, detail drawings and direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealent wherever required etc. but excluding the cost of purlins, rafters and trusses.BI01010001010000000000000515BI010000117596.382sqm
641.63od194806/2020_2021 : Providing and fixing M.S. round or square bars with M.S. flats at required spacing in frames of windows by welding including priming coat with approved steel primer, all complete as per directions of Engineer-in-chargeBI01010001010000000000000515BI01000011761959.12kg
651.64od178568/2020_2021 : Providing and fixing stainless steel Brushed mat finish (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) Weight of steel should check in site and measurement taken in kg.BI01010001010000000000000515BI01000011771275.58kg
661.6510.26.1 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tubeBI01010001010000000000000515BI01000011781478.47kg
671.6612.51.6 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Gutter (600 mm over all girth)BI01010001010000000000000515BI010000117968.74metre
681.6721.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)BI01010001010000000000000515BI01000011802835.07kg
691.68od197225/2020_2021 : Providing and fixing 8mm thick toughened glass panes (Saint Gobain/ Borosil/ La-Opala/ Equivalent) in aluminium partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. (Cost of aluminium snap beading and aluminium structure shall be paid separately)BI01010001010000000000000515BI0100001181119.538sqm
701.69od197226/2020_2021 : Providing and fixing 6mm thick toughened glass panes (Saint Gobain/ Borosil/ La-Opala/ Equivalent) in uPVC doors with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. (Cost of shutters paid separately)BI01010001010000000000000515BI010000118247.205sqm
711.721.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thicknessBI01010001010000000000000515BI0100001183431.419sqm
721.71od195096/2020_2021 : Providing & fixing coloured float glass panes with putty and glazing clips in uPVC Ventillators all complete as per the drawings and directions of the Engineer-in-charge. 5.5 mm thick glass panesBI01010001010000000000000515BI01000011846.48sqm
731.7222.6 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)BI01010001010000000000000515BI0100001185998.106sqm
741.7316.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-Charge)BI01010001010000000000000515BI01000011864.049cum
751.74od178633/2020_2021 : Providing and Planting of Buffalo grass for Lawn in Ordinary soil including Breaking clods, Watering, Ramming and Sectioning of spoil bank etc., including all labour charges, etc., completeBI01010001010000000000000515BI0100001187143.27sqm
761.75od147572/2020_2021 : WATER CUTTING Providing and casting water cutting with Cement mortar 1:4 with specified measurement according to the direction of the engineer in site and as per the architectural drawingBI01010001010000000000000515BI0100001188446.131metre
771.76od195102/2020_2021 : Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing as per the directions of the Engineer-in-chargeBI01010001010000000000000515BI010000118926.65sqm
781.77od195117/2020_2021 : Providing and fixing Glass Reinforced Jali works in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 White cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc.BI01010001010000000000000515BI010000119085.789sqm
791.78od195129/2020_2021 : Providing cement plastering of 12 mm cement plaster of mix 1:4 (1 cement : 4 fine sand) with chicken mesh in column-wall and beam-wall joints as per the directions of the Engineer-in-chargeBI01010001010000000000000515BI0100001191300.481sqm
801.79od147578/2020_2021 : Exposed concreteBI01010001010000000000000515BI0100001192150.378sqm
811.8od178881/2020_2021 : Providing & fixing Stainless steel lettering for nameboard as per the size mentioned in drawing and quality approved by the Architect including labour charges etc complete - Size of the lettering is 20cm width, 25cm height, 3.3cm thickness each on granite slab fixed in the compound wallBI01010001010000000000000515BI01000011931L.S
821.81od195131/2020_2021 : LANDSCAPING TREES - Digging pits in all kinds of soil and refilling the same with good quality fertile and earth, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead lift etc as directed by engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all completeBI01010001010000000000000515BI010000119420holes
831.82od147580/2020_2021 : SHRUBS: Digging pits in all kinds of soil and refilling the same with good quality fertile and earth, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead lift etc as directed by engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all conveyance, transported without any damage to the root.BI01010001010000000000000515BI0100001195150each
841.83od147581/2020_2021 : CREEPERS: Planting creepers 60cm center (type of creeper specified below) by excavating trenches of size 30x30x30cm and refilling with good quality fertile red earth, river sand, dried cow dung manure and leaf mould mixed in the ratio 1:1:1:1, removal of rubbish and surplus earth if any, including leaf lift etc. as directed by engineer in-charge and supplying good healthy cuttings of creepers free of all pests and deseases from source of availability including all conveyance caring and protecting the creeper etc. complete cutting of minimum 60cm length.BI01010001010000000000000515BI0100001196100each
851.84od147583/2020_2021 : DUST BIN: Providing and fixing Dust bin inside of park and parking area. including cost of all items. as per design drawings including all necessary labour, lead, lift, etc. complete.BI01010001010000000000000515BI01000011973each
861.85od147584/2020_2021 : ADVERTISEMENT BOARD: Providing and fixing advertisement board. as per design and drawings including all necessary labour, lead, lift, etc. complete - Board with GI Sheet of 1.2mm thickness having a dimension of 2x2.5m fixed on 2” GI pipes of 3mm thickness painted with epoxy paint and letteringBI01010001010000000000000515BI01000011981each
872RETAINING WALL and COMPOUND WALLBI01010001010000000000000515BI0100001199
882.014.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)BI01010001010000000000000515BI010000120018.828cum
892.025.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal sizeBI01010001010000000000000515BI010000120187.032cum
902.035.9.1 : Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concreteBI01010001010000000000000515BI01000012024.4sqm
912.045.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantileversBI01010001010000000000000515BI0100001203234.207sqm
922.057.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)BI01010001010000000000000515BI0100001204214.651cum
932.065.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or moreBI01010001010000000000000515BI01000012058690.3kg
942.0750.6.1.1 : Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc completeBI01010001010000000000000515BI010000120647.609cum
952.086.27.1 : Brick work with common burnt clay modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand).From ground level upto plinth levelBI01010001010000000000000515BI010000120725.92cum
962.0913.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)BI01010001010000000000000515BI0100001208385.668sqm
972.113.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)BI01010001010000000000000515BI0100001209386.309sqm
982.1110.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.BI01010001010000000000000515BI01000012103277.06kilogram
992.1213.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new workBI01010001010000000000000515BI0100001211166.72sqm
1003OPEN WELLBI01010001010000000000000515BI0100001212
1013.012.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soilBI01010001010000000000000515BI0100001213105.976cum
1023.02od147435/2020_2021 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials. All kinds of soilBI01010001010000000000000515BI010000121410.598cum
1033.03od147439/2020_2021 : Extra for open well excavation in all classes of soil from 3 - 4.5mBI01010001010000000000000515BI010000121510.598cum
1043.04od147443/2020_2021 : 4 Extra for open well excavation in all classes of soil from 4.5-6mBI01010001010000000000000515BI010000121610.598cum
1053.05od147447/2020_2021 : 5 Extra for open well excavation in all classes of soil from 6-7.5mBI01010001010000000000000515BI010000121710.598cum
1063.06od147453/2020_2021 : Extra for open well excavation in all classes of soil from 7.50 - 9.00 mBI01010001010000000000000515BI010000121810.598cum
1073.07od147457/2020_2021 : Extra for open well excavation in all classes of soil from 9.00 - 10.5 mBI01010001010000000000000515BI010000121910.598cum
1083.08od147462/2020_2021 : Extra for open well excavation in all classes of soil from 10.5 - 12.00 mBI01010001010000000000000515BI010000122010.598cum
1093.09od147467/2020_2021 : Extra for open well excavation in all classes of soil from 12 - 13.5mBI01010001010000000000000515BI010000122110.598cum
1103.1od147474/2020_2021 : Extra for open well excavation in all classes of soil from 13.5 - 15.00 mBI01010001010000000000000515BI010000122210.598cum
1113.1160.2.2 : Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc completeBI01010001010000000000000515BI010000122312hour
1123.1250.5.7 : Reinforced cement concrete work in well-staining excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1. 5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI010000122425.106cum
1133.135.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or moreBI01010001010000000000000515BI01000012251757.42kilogram
1143.144.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)BI01010001010000000000000515BI01000012262.208cum
1153.155.9.12 : Centering and shuttering including strutting, etc. and removal of form for:Well steiningBI01010001010000000000000515BI0100001227244.921sqm
1163.1613.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)BI01010001010000000000000515BI010000122840.821sqm
1174Gate & Car ParkBI01010001010000000000000515BI0100001229
1184.0110.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksBI01010001010000000000000515BI01000012302052.01kg
1194.0250.12.2.1 : Providing & fixing Poly carbonate corrugated sheet 0.8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling / self tapping screw of size (5.5x55 mm) with EPDM seal complete upto any pitch in horizontal/ vertical/ curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size shapes where ever required.BI01010001010000000000000515BI010000123177.238sqm
1205PLUMBING ESTIMATEBI01010001010000000000000515BI0100001232
1215.01od199921/2020_2021 : Providing and fixing white vitreous china extended wall mounted European water closet of size 780x370x690 mm of approved shape and of superior quality with a price not less than Rs.7000/each, including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre /8 litres), including seat cover, angle cock and health faucet (all of make Jaquar/ equivalent), 15mm dia flexible water inlet pipe, 32mm dia pvc flush pipe, and cistern fittings, nuts bolts and gasket, connection to the soil line core cutting, refinishing etc complete as per the directions of the Engineer-in-chargeBI01010001010000000000000515BI010000123342each
1225.02od199923/2020_2021 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar and angle cocks of approved make (Jaquar/ equivalent), 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin half pedestal of size 630x450 mm (price not less than Rs.1500/each) with a pair of 15 mm C.P. brass pillar tapsBI01010001010000000000000515BI010000123435each
1235.03od200635/2020_2021 : Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, angle cock and health faucet (all of superior quality like Jaquar/ equivalent) with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required: Single half stall urinal (price not less than Rs.1600/each) with 5 litre PVC. automatic flushing cisternBI01010001010000000000000515BI010000123512each
1245.04od147448/2020_2021 : Supply and Installation of Counter Mount Kitchen sink , PVC Extension pipe and Flange, Standard waste coupling,wall chasing, refinishing etc.including the following :-BI01010001010000000000000515BI01000012367each
1255.05od147454/2020_2021 : Supply and Installation of site 15mm dia C.P brass Bib tap with wall flange including cutting and making good the wall wherever required(Jaquar ARI-39037/ equivalent)BI01010001010000000000000515BI010000123752each
1265.06od147463/2020_2021 : 6.Supply and Installation of 65mm Dia Butterfly valve including Wall cutting and making good in open terrace complete as required. (Supreme/Finolex/Astral or equivalent)BI01010001010000000000000515BI01000012382no
1275.07od147468/2020_2021 : Supply and Installation of 20mm Dia ss stop cock and allied including Wall cutting and making good in bathroom complete as required. (Jaquar Stopcock-Fus-29083k & Allied-Ald089/ equivalent)BI01010001010000000000000515BI010000123935no
1285.08od147475/2020_2021 : 9.Supply and Installation of 25mm Dia Brass valve including Wall cutting and making good in bathroom complete as required. (Supreme/Finolex/Astral or equivalent)BI01010001010000000000000515BI010000124010no
1295.09od147480/2020_2021 : Supply and Installation of 40mm Dia Brass valve including Wall cutting and making good in open terrace complete as required. (Supreme/Finolex/Astral or equivalent)BI01010001010000000000000515BI01000012414no
1305.1od147482/2020_2021 : 7.Supply and Installation of 50mm Dia Brass valve including Wall cutting and making good in open terrace complete as required. (Supreme/Finolex/Astral or equivalent)BI01010001010000000000000515BI01000012428no
1315.11od147489/2020_2021 : 1.Supply and Installation of Lead free PVC-U SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.chasing the walls,floor,concrete etc. as required , replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand ). Testing of the system for leakage and Air tightness (Supreme/Finolex/Astral or equivalent) - 50mm OD 6kg/sqcm Waste PipingBI01010001010000000000000515BI0100001243275metre
1325.12od147493/2020_2021 : Supply and Installation of Lead free PVC-U SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.chasing the walls, floor, concrete etc. as required, replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand). Testing of the system for leakage and Air tightness (Supreme/Finolex/Astral or equivalent) - 75mm OD Type-B Soil PipingBI01010001010000000000000515BI010000124424metre
1335.13od147499/2020_2021 : 11.2.Supply and Installation of Lead free PVC-U SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings.chasing the walls, floor, concrete etc. as required, replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand ). Testing of the system for leakage and Air tightness (Supreme/Finolex/Astral or equivalent) - 75mm OD Type-B Waste PipingBI01010001010000000000000515BI0100001245130metre
1345.14od147504/2020_2021 : 12.4.110mm OD 6kg/sqcm Rain Water PipingBI01010001010000000000000515BI0100001246200metre
1355.15od147509/2020_2021 : 12.3.Supply and Installation of Lead free PVC-U SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings. Ts, Elbows, Bends, Ys etc. Adapters, Air vents, Clamping with GI UClamps /supports, as required for firmliy installing the pipes and adjesent to the building/ chasing the walls, concrete etc. as required , replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand ). Testing of the system for leakage and Air tightness (Supreme/Finolex/Astral or equivalent) - 110mm OD Air vent pipeBI01010001010000000000000515BI0100001247180metre
1365.16od147513/2020_2021 : 12.2. Supply and Installation of Lead free PVC-U SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings. Ts, Elbows, Bends, Ys etc.. Adapters, Air vents, Clamping with GI UClamps /supports, as required for firmliy installing the pipes and adjesent to the building/ chasing the walls, concrete etc. as required, replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand). Testing of the system for leakage and Air tightness (Supreme/Finolex/Astral or equivalent) - 110mm OD Type-B waste PipingBI01010001010000000000000515BI0100001248260metre
1375.17od147517/2020_2021 : 12.1.Supply and Installation of Lead free PVC-U SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings. Ts, Elbows, Bends, Ys etc.. Adapters, Air vents, Clamping with GI UClamps /supports, as required for firmliy installing the pipes and adjesent to the building/ chasing the walls, concrete etc. as required, replastering and refinishing using cement plaster 1:3 mix (cement:coarse sand). Testing of the system for leakage and Air tightness (Supreme/Finolex/Astral or equivalent) - 110mm OD Type-B soil PipingBI01010001010000000000000515BI0100001249425metre
1385.18od147521/2020_2021 : Supply and Installation of Lead free UPVC SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings through trench having 60cm depth /as per site conditionand to make corresponding slope hence complete. [Excavation will be in the scope of contractor]. Testing of the system for leakage and Air tightness (Supreme/Finolex/Astral or equivalent) - 110mmOD Type-B soil pipingBI01010001010000000000000515BI0100001250200metre
1395.19od147524/2020_2021 : Supply and Installation of Lead free UPVC SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings through trench having 60cm depth /as per site condition and to make corresponding slope hence complete.[Excavation will be in the scope of contractor]. Testing of the system for leakage and Air tightness (Supreme/Finolex/Astral or equivalent) - 160mmOD Type-B soil pipingBI01010001010000000000000515BI010000125160metre
1405.2od147527/2020_2021 : Supply and Installation of Lead free UPVC SWR pasted pipe using Solvent Cement ISI Marked [As per IS 4985] with Heavy duty ISI Marked PVC fittings through trench having 60cm depth /as per site conditionand to make corresponding slope hence complete.[Excavation will be in the scope of contractor]. Testing of the system for leakage and Air tightness (Supreme/Finolex/Astral or equivalent) - 200mmOD Type-B rain water pipingBI01010001010000000000000515BI0100001252170metre
1415.21od147529/2020_2021 : Supply and Installation of 125x125mm CP Stainless Steel Gratings with Cockroach Protection for multi inlet floor trap.BI01010001010000000000000515BI010000125390no
1425.22od147531/2020_2021 : Multi Inlet floor trap 110x75x50mm.BI01010001010000000000000515BI010000125490no
1435.23od147533/2020_2021 : Supply and Installing at site Open UPVC Lead Free ASTM Schedule 40 Pipes (Equivalent Standard Size) with all accessories like bends, y's etc for Water supply Joined using Solvent Cement fittings suitable for the working pressure. Supporting exposed pipes using cement mortar at 60 cm intervals above terrace floor. Hydrostatic Testing of the Pipes using 10KG/cm2 test pressure for specified time period (Supreme/Finolex/Astral or equivalent) - 50mm Nominal DiaBI01010001010000000000000515BI010000125540metre
1445.24od147535/2020_2021 : Supply and Installing at site Open UPVC Lead Free ASTM Schedule 40 Pipes (Equivalent Standard Size) with all accessories like bends, y's etc for Water supply Joined using Solvent Cement fittings suitable for the working pressure. Supporting exposed pipes using cement mortar at 60 cm intervals above terrace floor. Hydrostatic Testing of the Pipes using 10KG/cm2 test pressure for specified time period (Supreme/Finolex/Astral or equivalent) - 63mm Nominal DiaBI01010001010000000000000515BI010000125660metre
1455.25od147537/2020_2021 : Supply and Installing at site Concealed UPVC ASTM Schedule 40 Pipes of Equivalent Standard Size with all accessories like bends, y's etc for Water supply Joined using Solvent Cement fittings with metal in-serts suitable for the working pressure. Chasing of the walls, concrete etc. as required, replastering and refinishing using Cement Plaster 1:3 mix [Cement : Coarse sand]. Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period (Supreme/Finolex/Astral or equivalent) - 25mm Nominal DiaBI01010001010000000000000515BI0100001257190metre
1465.26od147538/2020_2021 : Supply and Installing at site Concealed UPVC ASTM Schedule 40 Pipes of Equivalent Standard Size with all accessories like bends,y's etc for Water supply Joined using Solvent Cement fittings with metal in-serts suitable for the working pressure. Chasing of the walls, concrete etc. as required, replastering and refinishing using Cement Plaster 1:3 mix [Cement : Coarse sand]. Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period (Supreme/Finolex/Astral or equivalent) - 20mm Nominal DiaBI01010001010000000000000515BI0100001258460metre
1475.27od147540/2020_2021 : Supply and Installing at site Concealed UPVC ASTM Schedule 40 Pipes of Equivalent Standard Size with all accessories like bends, y's etc for Water supply Joined using Solvent Cement fittings with metal in-serts suitable for the working pressure. Through open walls, concrete etc. using GI clamps/supports as required, Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period (Supreme/Finolex/Astral or equivalent) - 50mm Nominal DiaBI01010001010000000000000515BI0100001259160metre
1485.28od147542/2020_2021 : Supply and Installing at site Concealed UPVC ASTM Schedule 40 Pipes of Equivalent Standard Size with all accessories like bends,y's etc for Water supply Joined using Solvent Cement fittings with metal in-serts suitable for the working pressure. Through open walls, concrete etc. using GI clamps/supports as required, Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period (Supreme/Finolex/Astral or equivalent) - 32mm Nominal DiaBI01010001010000000000000515BI010000126055metre
1495.29od147543/2020_2021 : Supply and Installing at site Concealed UPVC ASTM Schedule 40 Pipes of Equivalent Standard Size with all accessories like bends,y's etc for Water supply Joined using Solvent Cement fittings with metal in-serts suitable for the working pressure. Through open walls, concrete etc. using GI clamps/supports as required, Hydrostatic Testing of the Pipes using 10kg/cm2 test pressure for specified time period (Supreme/Finolex/Astral or equivalent) - 25mm Nominal DiaBI01010001010000000000000515BI010000126135metre
1505.3od147546/2020_2021 : Supply, Installing and Leveling Pipe Supports Fabricated from GI Slotted Rails / Channels of corresponding as per the site condition width suitable for carrying the operating weight of pipe and the fluids, 8mm Dia GI Adjustable Threaded Rods and Anchor Fasteners on wall, U clamps etc.as appropriate.BI01010001010000000000000515BI0100001262400no
1515.31od147548/2020_2021 : Labour charges for core cutting of slabs/beam for pipes of following sizes - 110mm diaBI01010001010000000000000515BI0100001263108no
1525.32od147550/2020_2021 : Labour charges for core cutting of slabs/beam for pipes of following sizes - 50mm diaBI01010001010000000000000515BI010000126426no
1535.33od147552/2020_2021 : Labour charges for core cutting of slabs/beam for pipes of following sizes - 40mm diaBI01010001010000000000000515BI010000126515no
1545.34od147553/2020_2021 : Labour charges for core cutting of slabs/beam for pipes of following sizes - 25mm diaBI01010001010000000000000515BI01000012668no
1555.35od147556/2020_2021 : Labour charges for core cutting of slabs/beam for pipes of following sizes - 75mm diaBI01010001010000000000000515BI01000012674no
1565.36od147557/2020_2021 : Supply and Installation of Towel Ring (Jaquar ACN-1121BN/ equivalent)BI01010001010000000000000515BI010000126815no
1575.37od147558/2020_2021 : Supply and Installation of Towel Rod (Jaquar ACN-1111NM/ equivalent)BI01010001010000000000000515BI010000126950no
1585.38od147559/2020_2021 : Supply and installation of rob hook (Jaquar AEC-CHR-1161/ equivalent)BI01010001010000000000000515BI0100001270150no
1595.39od147560/2020_2021 : Supply and Installation of 40mm Non-returning valves (Supreme/Finolex/Astral or equivalent)BI01010001010000000000000515BI01000012714no
1605.4od147561/2020_2021 : Supply and Installation of 40mm Air releasing valve (Supreme/Finolex/Astral or equivalent)BI01010001010000000000000515BI01000012724no
1615.41od147562/2020_2021 : Supply and Installation of flow switch system for water level controling (sontay/system sensor)BI01010001010000000000000515BI01000012732no
1625.42od147563/2020_2021 : Supply and laying of 40mm nomial dia scheduled40 astm from well to tank (Supreme/Finolex/Astral or equivalent)BI01010001010000000000000515BI0100001274110metre
1635.43od147564/2020_2021 : Supply and Labour for installation of motor pump having minimum of 150 LPM discharge at 25m head including all required accessories like foot valve etc Make : 1.5HP crompton greaves/grundfos or equivalentBI01010001010000000000000515BI01000012754no
1645.44od147565/2020_2021 : Supply and installation of uPVC LH & RH 45° junction in ground having 600 mm base, 110mm dia inlet/outlet and 160 mm dia branch inlet with riser, heavy duty CI cover, frame and all accessories (Supreme or equivalent)BI01010001010000000000000515BI010000127610no
1655.45od147568/2020_2021 : Supply and installation of uPVC 90° / LH & RH 45° junction in ground having 315 mm base, 110mm dia inlet/outlet and 110 mm dia branch inlet with riser, heavy duty CI cover, frame and all accessories (Supreme or equivalent)BI01010001010000000000000515BI010000127714no
1666SUMPBI01010001010000000000000515BI0100001278
1676.012.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soilBI01010001010000000000000515BI0100001279398.821cum
1686.025.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal sizeBI01010001010000000000000515BI010000128045.752cum
1696.03od187229/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All work upto plinth levelBI01010001010000000000000515BI010000128139.902cum
1706.045.9.1 : Centering and shuttering including strutting, etc. and removal of form for: Foundations, footings, bases of columns, etc for mass concreteBI01010001010000000000000515BI0100001282516.53sqm
1716.055.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or moreBI01010001010000000000000515BI01000012838565.4kg
1726.06od147459/2020_2021 : providing and fixing cast iron manhole cover including material and labour charges completeBI01010001010000000000000515BI0100001284960each
1736.07od147465/2020_2021 : Providing glass for opening grill workBI01010001010000000000000515BI01000012854.41sqm
1746.0810.25.1 : Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all completeBI01010001010000000000000515BI0100001286129.2kg
1756.0910.25.2 : Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksBI01010001010000000000000515BI0100001287135.24kg
1767SEPTIC TANK and SOAK PITBI01010001010000000000000515BI0100001288
1777.012.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soilBI01010001010000000000000515BI010000128938.5cum
1787.024.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)BI01010001010000000000000515BI01000012901.3cum
1797.0360.7.1 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at siteBI01010001010000000000000515BI01000012916cum
1807.045.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal sizeBI01010001010000000000000515BI010000129213.802cum
1817.055.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concreteBI01010001010000000000000515BI010000129395.651sqm
1827.065.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or moreBI01010001010000000000000515BI01000012941380.2kg
1837.0713.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 (1 cement : 3 fine sand)BI01010001010000000000000515BI010000129594.741sqm
1847.0823.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- chargesBI01010001010000000000000515BI01000012963.125cum
1857.0923.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-ChargeBI01010001010000000000000515BI01000012973.125cum
1867.123.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.BI01010001010000000000000515BI01000012983.125cum
1877.11od147470/2020_2021 : Manhole using Cast iron 60x60cm sizeBI01010001010000000000000515BI0100001299480kg
1888Fire EstimationBI01010001010000000000000515BI0100001300
1898.01od110248/2020_2021 : MS pipe 100 mm diaBI01010001010000000000000515BI010000130195metre
1908.02od110253/2020_2021 : MS pipe 80 mm diaBI01010001010000000000000515BI010000130281metre
1918.03od110254/2020_2021 : MS pipe 65 mm diaBI01010001010000000000000515BI010000130347metre
1928.04od110258/2020_2021 : MS pipe 50 mm diaBI01010001010000000000000515BI010000130418metre
1938.05od110264/2020_2021 : MS pipe 40 mm diaBI01010001010000000000000515BI010000130579metre
1948.06od110266/2020_2021 : MS pipe 32 mm dia 1 m /31.1kg/mBI01010001010000000000000515BI0100001306124metre
1958.07od110300/2020_2021 : MS pipe 32 mm dia 1 m /2.41kg/mBI01010001010000000000000515BI0100001307435metre
1968.08od110353/2020_2021 : Under ground piping -100mm diaBI01010001010000000000000515BI010000130830metre
1978.09od110377/2020_2021 : Hydraulic Hose Reel drumBI01010001010000000000000515BI01000013098each
1988.1od110452/2020_2021 : Ball valveBI01010001010000000000000515BI01000013108each
1998.11od110465/2020_2021 : GM Single Headed Hydrant Valve 63 mm diaBI01010001010000000000000515BI01000013118each
2008.12od110481/2020_2021 : Single Door Hose CabinetBI01010001010000000000000515BI01000013128each
2018.13od110493/2020_2021 : GM Branch pipe, ISI marked 63 mm Female Instantaneous inletBI01010001010000000000000515BI01000013138each
2028.14od110500/2020_2021 : Controlled Percolated Hose Conforming to IS: 636, 63 mm dia 15 mtrs.BI01010001010000000000000515BI01000013148each
2038.15od110532/2020_2021 : Single Acting Release valve with screwed inlet 20 mm diaBI01010001010000000000000515BI01000013152each
2048.16od110544/2020_2021 : Fire Brigade with inlet connection with 3 Nos of 63 mm dia.BI01010001010000000000000515BI01000013161each
2058.17od110551/2020_2021 : Electrically Driven Mono Block Terrace pump of capacity 900 LPMBI01010001010000000000000515BI01000013171each
2068.18od110560/2020_2021 : Electrically Driven Mono Block pump of capacity 2280 LPMBI01010001010000000000000515BI01000013181each
2078.19od110579/2020_2021 : Electrically Driven Mono Block pump of capacity 180 LPMBI01010001010000000000000515BI01000013191each
2088.2od110590/2020_2021 : Diesel operated Mono block pump of capacity 2280 LPMBI01010001010000000000000515BI01000013201each
2098.21od110726/2020_2021 : Pressure GaugeBI01010001010000000000000515BI01000013211each
2108.22od110732/2020_2021 : CI Butterfly valve slim seal standard lever operates type 100 mm diaBI01010001010000000000000515BI010000132212each
2118.23od110743/2020_2021 : CI Butterfly valve slim seal standard lever operates type 80 mm diaBI01010001010000000000000515BI01000013238each
2128.24od110750/2020_2021 : CI Non Return Valve slim seal type with required flangesBI01010001010000000000000515BI01000013246each
2138.25od110773/2020_2021 : Sprinkled heads designed to operate at 68 deg celcious etsBI01010001010000000000000515BI0100001325304each
2148.26od110799/2020_2021 : Sign boards made out of 3 mm thick \"Opaque\" PVC foam board with computer cutBI01010001010000000000000515BI010000132612each
2158.27od110843/2020_2021 : Indoor type Exit board with LED Lamps reflector indicating arrows with exit recess mounted typeBI01010001010000000000000515BI01000013278each
2168.28od110850/2020_2021 : Manuel call point break glass typeBI01010001010000000000000515BI01000013288each
2178.29od110860/2020_2021 : Electronic dual tone HooterBI01010001010000000000000515BI01000013298each
2188.3od110863/2020_2021 : Main Fire alarm control panel of 4 Zones capacity with visual Led indication for fireBI01010001010000000000000515BI01000013301each
2198.31od110869/2020_2021 : PVC conduit 20 mm diaBI01010001010000000000000515BI0100001331187metre
2208.32od110883/2020_2021 : 1 sq.mm Cross section PVC insulated copper wiresBI01010001010000000000000515BI0100001332364metre
2218.33od110886/2020_2021 : Fire ExtinguishersBI01010001010000000000000515BI01000013338no
2229ELECTRICAL ESTIMATEBI01010001010000000000000515BI0100001334
2239.0190.12.7.12 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3 core 4 sq mm with factory made clamp.BI01010001010000000000000515BI010000133595metre
2249.0290.12.7.28 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 35 sq mm with factory made clampBI01010001010000000000000515BI010000133675metre
2259.0390.12.7.29 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 50 sq mm with factory made clampBI01010001010000000000000515BI0100001337120metre
2269.0490.12.7.31 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 95 sq mm.BI01010001010000000000000515BI010000133820metre
2279.0590.12.7.38 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 4 sq mm with factory made clampBI01010001010000000000000515BI010000133940metre
2289.0690.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 10 sq mm with factory made clampBI01010001010000000000000515BI0100001340135metre
2299.0790.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 16 sq mm with factory made clampBI01010001010000000000000515BI010000134175metre
2309.0890.12.7.42 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 25 sq mm with factory made clampBI01010001010000000000000515BI010000134265metre
2319.099.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 10 sq. mm (25mm)BI01010001010000000000000515BI010000134312set
2329.19.2.18 : Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 35 sq. mmBI01010001010000000000000515BI01000013442each
2339.119.2.19 : Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mmBI01010001010000000000000515BI01000013454each
2349.129.2.21 : Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 95 sq. mmBI01010001010000000000000515BI01000013464each
2359.139.2.29 : Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mmBI01010001010000000000000515BI010000134712each
2369.149.2.30 : Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mmBI01010001010000000000000515BI01000013484each
2379.155.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as requiredBI01010001010000000000000515BI010000134912set
2389.165.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)BI01010001010000000000000515BI0100001350155metre
2399.171.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC\ninsulated copper conductor single core cable in surface / recessed medium class PVC conduit,\nwith modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS\nPVC insulated copper conductor single core cable etc as required.Group BBI01010001010000000000000515BI0100001351330point
2409.181.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.BI01010001010000000000000515BI010000135230point
2419.191.17.9 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mmBI01010001010000000000000515BI010000135345metre
2429.21.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mmBI01010001010000000000000515BI0100001354250metre
2439.211.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wireBI01010001010000000000000515BI01000013554000metre
2449.221.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wireBI01010001010000000000000515BI01000013561200metre
2459.231.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wireBI01010001010000000000000515BI0100001357400metre
2469.244.1.14 : Supplying and installing following size of perforated pre-painted M.S. cable trays with\nperforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 75 mm depth X 2.0 mm thicknessBI01010001010000000000000515BI0100001358395metre
2479.254.2.13 : Supplying and installing following size of perforated pre-painted M.S. cable trays bends with\nperforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.900 mm width X 62.5 mm depth X 2.0 mm thicknessBI01010001010000000000000515BI010000135925no
2489.262.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double doorBI01010001010000000000000515BI01000013604each
2499.272.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single poleBI01010001010000000000000515BI0100001361164each
2509.282.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple poleBI01010001010000000000000515BI010000136210each
2519.292.12.2 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 ampsBI01010001010000000000000515BI01000013631each
2529.32.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 ampsBI01010001010000000000000515BI01000013643each
2539.312.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 ampsBI01010001010000000000000515BI01000013654each
2549.321.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings).BI01010001010000000000000515BI010000136663each
2559.331.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.BI01010001010000000000000515BI010000136730each
2569.341.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).BI01010001010000000000000515BI010000136888each
2579.35od115309/2020_2021 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator), 6 way (4+18), Double doorBI01010001010000000000000515BI01000013692each
2589.36od115357/2020_2021 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4+12), Double doorBI01010001010000000000000515BI01000013706each
2599.37od115886/2020_2021 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But with out MCB/RCCB/Isolator), 4 way (4+12), Double doorBI01010001010000000000000515BI01000013716each
2609.382.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 ampsBI01010001010000000000000515BI01000013722each
2619.39od161561/2020_2021 : \"MSB WITH METERING\" Supply, Installation, Testing and commissioning of 125 A MV Cubicle panel board. front opening type, wall mounted free standing on 3\" MS channel directly bolted to wall using nuts and bolts stenciling all identification etc.. confirming to IS1863, IE rules. Incomer 125A TP 36kA MCCB variable setting with inbuit EF release - 1 No. Class B&C Surge arrestor Type 1, Type 2 Outgoings 100A TP 25ka MCCB with all isolation duty and 3 Nos.125A cut out fuse unit and provision for CT net metering -1nos. 63A TPN 25ka MCCB with all isolation duty and 3 Nos.63A cut out fuse unit and provision for KWH meter-1nos. 63A 4P ACCL without Current limiter. All MCCBs are with rotary operating handle for door interlock. Busbar :125A TPN Al busbarBI01010001010000000000000515BI01000013731each
2629.4od161562/2020_2021 : \"LCP Supply, Installation, Testing and commissioning of 40A MV Cubicle panel. Fabricated out of 16 swg CR CA sheet, powder coated dust and vermin tight proof, front opening type, flush and floor mounted free standing on 3\" MS channel directly bolted to floor using nuts and bolts stenciling all identification etc.. confirming to IS1863, IE rules; INCOMER: 40A TPN MCB isolator - 1NOS; RYB Pilolet lamp - 1NOS; OUTGOING: 40A 4P 30MA RCCB - 1NOS; 25A DP 30MA RCCB with 4nos of 6A SP MCB - 1nos; Busbar: 40A TPN Al busbar\"BI01010001010000000000000515BI01000013741each
2639.41od161564/2020_2021 : \"SSB Supply, Installation, Testing and commissioning of 100A MV Cubicle panel. Fabricated out of 16 swg CR CA sheet, powder coated dust and vermin tight proof, front opening type, flush and floor mounted free standing on 3\" MS channel directly bolted to floor using nuts and bolts stenciling all identification etc.. confirming to IS1863, IE rules; Incomer:100A TPN ISO - 1Nos.; 100A TPN ISO - 1Nos.; 100A 4P AC-1 Duty Contactor - 2Nos; RYB Piolet Lamps-2Set; Multifunction Meter-1No.; Outgoings 63A TP 18KA MCCB - 6 Nos; 40A TP 18KA MCCB - 3 Nos.; 80A TPN MCCB-1Nos [solar]; 63A 4P Isolator-1Nos; Electrical and mechanical interlocking shall be done. Microprocessor based AMF relay; All MCCBs are with rotary operating handle for door interlock. Busbar :100A TPN Al busbar\"BI01010001010000000000000515BI01000013751each
2649.422.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 ampsBI01010001010000000000000515BI01000013766each
2659.431.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.BI01010001010000000000000515BI0100001377100each
2669.441.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switchBI01010001010000000000000515BI010000137826each
2679.451.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outletBI01010001010000000000000515BI010000137926each
2689.461.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outletBI01010001010000000000000515BI010000138050each
2699.4790.16.3.8 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required (for horizontal run) 20 x 3 mm copper stripBI01010001010000000000000515BI0100001381334metre
2709.4890.16.4.7 : Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required (for vertical run). 20 x 3 mm copper stripBI01010001010000000000000515BI0100001382141metre
2719.4990.16.1.5 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required. 75mm copper conductor (6 SWG)BI01010001010000000000000515BI0100001383125metre
2729.5od162126/2020_2021 : Supply and Fixing of laminated schematic drawings.BI01010001010000000000000515BI01000013841each
2739.51od162127/2020_2021 : Supply and Fixing of 2Nos. 9 litres red colour fire bucket on standsBI01010001010000000000000515BI01000013852each
2749.52od162128/2020_2021 : Supply and Fixing of 5kg dry powder fire extinguishers on clamp.BI01010001010000000000000515BI01000013862each
2759.53od162129/2020_2021 : supply and fixing of 440 V grade synthetic insulated mat 2 meter x 1 meter x 6mm conforming to IS:15652:2006BI01010001010000000000000515BI01000013874each
2769.54od162130/2020_2021 : Supply and fixing of shock treatment chart in glass with frameBI01010001010000000000000515BI01000013881each
2779.55od162131/2020_2021 : Supply and fixing of LT danger boardsBI01010001010000000000000515BI01000013891each
2789.56od162274/2020_2021 : \"GSB; Supply, Installation, Testing and commissioning of 125A MV Cubicle panel. Fabricated out of 16 swg CR CA sheet, powder coated dust and vermin tight proof, front opening type, flush and floor mounted free standing on 3\" MS channel directly bolted to floor using nuts and bolts stenciling all identification etc.. confirming to IS1863, IE rules; Incomer 125A TPN isolator - 1nos; RYB piolet lamp - 1nos; Reverse Power Relay 415V AC -1nos; Outgoing100A TPN 25KA MCCB - 1 nos; 63A TPN 25KA MCCB -1No; All MCCBs are with rotary operating handle for door interlock; Busbar:125A TPN Al busbarBI01010001010000000000000515BI01000013901each
2799.571.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)BI01010001010000000000000515BI010000139174each
2809.58od162345/2020_2021 : Supply and fixing of DOL starter for 1.5Hp in open enclosure with required capacitor with on/off push buttonBI01010001010000000000000515BI01000013924each
2819.59od162346/2020_2021 : Supply and installation of IP-65 junction box suitable for connecting 3x2.5 sqmm cu cableBI01010001010000000000000515BI010000139315each
2829.6od162347/2020_2021 : Supply and installation of 63A 4P cubical isolator with open enclosure IP based<br>BI01010001010000000000000515BI01000013944each
2839.61od162348/2020_2021 : Supply and Installation of V25 B+C/3+NPE 320VBI01010001010000000000000515BI01000013955each
2849.62od162349/2020_2021 : Supply and installation of RJ 45 socket With ShutterBI01010001010000000000000515BI010000139674each
2859.6314.4 : Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.BI01010001010000000000000515BI010000139754cum
2869.6414.9 : Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.BI01010001010000000000000515BI01000013985cum
2879.6514.11 : Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.BI01010001010000000000000515BI010000139940cum
2889.66od162549/2020_2021 : Supply and labour charges for Fixing of 40W post top light with 3mtr poleBI01010001010000000000000515BI010000140015each
2899.67od162550/2020_2021 : Supply and labour charges for Fixing of 20w tube light 1200mmBI01010001010000000000000515BI010000140114each
2909.68od162551/2020_2021 : Supply and labour charges for Fixing of Mirror Light 10W 2feet battern lightBI01010001010000000000000515BI010000140228each
2919.69od162552/2020_2021 : Supply and labour charges for Fixing of Ceiling exhaust fan 28w ceiling mounting white vent air sweep 130 mmBI01010001010000000000000515BI010000140327each
2929.7od162553/2020_2021 : Supply and labour charges for Fixing of Wall Fan 60W 450mm sweepBI01010001010000000000000515BI010000140410each
2939.71od162554/2020_2021 : Supply and labour charges for Fixing of Wall Exhaust Fan 9 InchBI01010001010000000000000515BI010000140527each
2949.72od162555/2020_2021 : Supply and labour charges for Fixing of Ceiling fan 1200 mmBI01010001010000000000000515BI0100001406100each
2959.73od162556/2020_2021 : Supply and labour charges for Fixing of 9w Square LED Panel Ceiling LightBI01010001010000000000000515BI0100001407421each
2969.74od162557/2020_2021 : Supply and labour charges for Fixing of 12W Round LED Panel Ceiling LightBI01010001010000000000000515BI010000140818each
2979.75od162558/2020_2021 : Supply and labour charges for Fixing of 18w Round LED Panel Ceiling LightBI01010001010000000000000515BI010000140952each
2989.76od162559/2020_2021 : Supply and labour charges for Fixing of 6W Round LED Panel Ceiling LightBI01010001010000000000000515BI010000141066each
2999.77od162561/2020_2021 : Supply and labour charges for Fixing of 18W Exterior Wall light - Bulk HeadBI01010001010000000000000515BI010000141110each
3009.78od162562/2020_2021 : Supply and labour charges for Fixing of 12w Wall light(wall washer)BI01010001010000000000000515BI010000141210each
3019.796.3 : Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.BI01010001010000000000000515BI01000014132each
3029.8od162574/2020_2021 : Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, copper tube,having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc.complete as required.BI01010001010000000000000515BI01000014142each
3039.81od162662/2020_2021 : Preparation of necessary drawing and getting all necessary approvals/sanction, inspection,supervision charges etc.from EI/EB including all sundries expenses except statutory charges. Statutory charges shall be reimbursed only after producing valid proofBI01010001010000000000000515BI01000014151L.S
3049.82od162663/2020_2021 : Supply and labour charges for Fixing of 12W T bulb with holderBI01010001010000000000000515BI010000141610each
3059.838.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mmBI01010001010000000000000515BI0100001417100metre
3069.8410.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mmBI01010001010000000000000515BI01000014182each
3079.85od190007/2020_2021 : Supply of following 11 KV XLPE UG cable in existing open trench/ open tray 3cx300sq mmBI01010001010000000000000515BI0100001419100metre
30810AC ESTIMATEBI01010001010000000000000515BI0100001420
30910.01od116004/2020_2021 : Supply, Installation, Testing & Commissioining of Armoured control cum transmission wiring between ODU & IDU of required size with pvc conduit and other accessories as per specification and relavent standards, and all other electrical connections from isolator to the unitsBI01010001010000000000000515BI0100001421280metre
31010.02od116043/2020_2021 : Condensate Piping Supply and erection of the condensate UPVC pipes with all joints, reducers, necessary elbows and tees, supporting arrangements etc. Rate shall inclusive of thermal insulation with 13mm thickness FM approved closed cell nitrile rubber insulation covering with fire resistant fibre cloth fabric as a resistant to scracth and mechanical impacts 25mm Dia UPVCBI01010001010000000000000515BI0100001422230metre
31110.03od116051/2020_2021 : Supply and labour for installation of Refnut Y jointsBI01010001010000000000000515BI010000142310each
31210.04od116146/2020_2021 : Supply and labour for Refrigerant gas charging R410 gasBI01010001010000000000000515BI010000142430kg
31310.05od116305/2020_2021 : \"Refrigerant Piping- Supply and errection of 16gauge hard drawn refrigerant copper pipe to integrate out door/ indoor units. The rate shall inclusive of closed cell nitrile rubber insulation for copper pipes and fiber glass cloth covering. The FRP/poly shield coating shall be applied over the insulation for exposed application. Pipe size and insulation thickness as follows\" 9.5mm with 6.35mm thick insulationBI01010001010000000000000515BI01000014256metre
31410.06od116312/2020_2021 : \"Refrigerant Piping- Supply and errection of 16gauge hard drawn refrigerant copper pipe to integrate out door/ indoor units. The rate shall inclusive of closed cell nitrile rubber insulation for copper pipes and fiber glass cloth covering. The FRP/poly shield coating shall be applied over the insulation for exposed application. Pipe size and insulation thickness as follows\" 12.7 mm with 6.35 mm thick insulationBI01010001010000000000000515BI010000142658metre
31510.07od116329/2020_2021 : \"Refrigerant Piping- Supply and errection of 16gauge hard drawn refrigerant copper pipe to integrate out door/ indoor units. The rate shall inclusive of closed cell nitrile rubber insulation for copper pipes and fiber glass cloth covering. The FRP/poly shield coating shall be applied over the insulation for exposed application. Pipe size and insulation thickness as follows\" 15.9mm with 9.5mm thick insulationBI01010001010000000000000515BI010000142725metre
31610.08od116342/2020_2021 : \"Refrigerant Piping- Supply and errection of 16gauge hard drawn refrigerant copper pipe to integrate out door/ indoor units. The rate shall inclusive of closed cell nitrile rubber insulation for copper pipes and fiber glass cloth covering. The FRP/poly shield coating shall be applied over the insulation for exposed application. Pipe size and insulation thickness as follows\" 19.1mm with 9.5 mm thick insulationBI01010001010000000000000515BI010000142865metre
31710.09od116374/2020_2021 : \"Refrigerant Piping- Supply and errection of 16gauge hard drawn refrigerant copper pipe to integrate out door/ indoor units. The rate shall inclusive of closed cell nitrile rubber insulation for copper pipes and fiber glass cloth covering. The FRP/poly shield coating shall be applied over the insulation for exposed application. Pipe size and insulation thickness as follows\" 28.6 mm with 12.7 mm thick insulationBI01010001010000000000000515BI010000142970metre
31810.1od116379/2020_2021 : \"Refrigerant Piping - Supply and errection of 16gauge hard drawn refrigerant copper pipe to integrate out door/ indoor units. The rate shall inclusive of closed cell nitrile rubber insulation for copper pipes and fiber glass cloth covering. The FRP/poly shield coating shall be applied over the insulation for exposed application. Pipe size and insulation thickness as follows\" 22.2 mm with 9.5 mm thick insulationBI01010001010000000000000515BI01000014306metre
31910.11od116384/2020_2021 : \"OUT DOOR UNITS Supply, Installation, testing and commissioning of out door units consist of 100% inverter scroll compressor/twin rotary compressors, Dc fan Motor with aero-spiral fan blade, e-pass heat exchangers, safety valves, solenoid valves, receiver, capillary tubes, check valve, electronic expansion valve, High pressure switch, low pressure sensor, pressure regulating valve, refrigerant filter, stop valve, accumulator and refnet kits. Rate inclusive of R-410A refrigerant and oil pre charging, power cable from nearest isolator, vibration isolators, supports, necessary foundation/ pedestal works etc..(High COP Models)\" 14HPBI01010001010000000000000515BI01000014312each
32010.12od116389/2020_2021 : \"INDOOR UNITS Design, Supply, Installation, testing and Commissioning of VRF indoor air conditioning units with direct driven fan, high efficient filter, Inbulit micro controller thermostat, electronic expansion valve, Remote controller including cables, neccessory supports and vibratrion isolators, Refrigerant charging, refnet joints for both liquid and gas lines branch kits, control wiring, power cables form nearest socket including plug, drain connections etc.. Capacities as mensioned below\" FOUR-WAY CASSETTE AC(VRF) a) Cooling capacity-3TRBI01010001010000000000000515BI01000014324each
32110.13od116392/2020_2021 : \"INDOOR UNITS Design, Supply, Installation, testing and Commissioning of VRF indoor air conditioning units with direct driven fan, high efficient filter, Inbulit micro controller thermostat, electronic expansion valve, Remote controller including cables, neccessory supports and vibratrion isolators, Refrigerant charging, refnet joints for both liquid and gas lines branch kits, control wiring, power cables form nearest socket including plug, drain connections etc.. Capacities as mensioned below\" HI-WALL SPLIT AC(VRF) d) Cooling capacity-0.8TRBI01010001010000000000000515BI01000014331each
32210.14od116445/2020_2021 : \"INDOOR UNITS Design, Supply, Installation, testing and Commissioning of VRF indoor air conditioning units with direct driven fan, high efficient filter, Inbulit micro controller thermostat, electronic expansion valve, Remote controller including cables, neccessory supports and vibratrion isolators, Refrigerant charging, refnet joints for both liquid and gas lines branch kits, control wiring, power cables form nearest socket including plug, drain connections etc.. Capacities as mensioned below\" HI-WALL SPLIT AC(VRF) c) Cooling capacity-1.5TRBI01010001010000000000000515BI01000014346each
32310.15od116450/2020_2021 : \"INDOOR UNITS Design, Supply, Installation, testing and Commissioning of VRF indoor air conditioning units with direct driven fan, high efficient filter, Inbulit micro controller thermostat, electronic expansion valve, Remote controller including cables, neccessory supports and vibratrion isolators, Refrigerant charging, refnet joints for both liquid and gas lines branch kits, control wiring, power cables form nearest socket including plug, drain connections etc.. Capacities as mensioned below\" HI-WALL SPLIT AC(VRF) b)Cooling capacity-2TRBI01010001010000000000000515BI01000014351each
32410.16od116452/2020_2021 : \"INDOOR UNITS Design, Supply, Installation, testing and Commissioning of VRF indoor air conditioning units with direct driven fan, high efficient filter, Inbulit micro controller thermostat, electronic expansion valve, Remote controller including cables, neccessory supports and vibratrion isolators, Refrigerant charging, refnet joints for both liquid and gas lines branch kits, control wiring, power cables form nearest socket including plug, drain connections etc.. Capacities as mensioned below\" HI-WALL SPLIT AC(VRF) a) Cooling capacity-2.5TRBI01010001010000000000000515BI01000014362each
32511DIESEL GENERATORBI01010001010000000000000515BI0100001437
32611.01od162195/2020_2021 : Supply and Labour charges for erection of additional length of MS[B class medium grade]exhaust pipe line of suitable sizes, with heat resistant Al painting to building top for 82.5 KVA DG.BI01010001010000000000000515BI010000143820metre
32711.02od162196/2020_2021 : \"Diesel generator; Supply and Labour for Installation, testing & commissioning of 3 phase 82.5 KVA Diesel generator, including required earthing, power/control cabling, terminations including getting the necessary clearance/approval of generator from electrical inspectorate, testing of neutral CT, relays, meters etc.. as required[statutory charges shall be borne by the clients on production of valid proof][ Mechanical erection of packaged generator will be done by the generator supplier]\"BI01010001010000000000000515BI01000014391each
32812UPSBI01010001010000000000000515BI0100001440
32912.01od162234/2020_2021 : \"UPS; Supply and Labour for installation of 3 phase in single phase out 20kVA UPS with battery bank SMF type having 20 minutes back up\"BI01010001010000000000000515BI01000014411each
33013LIFTBI01010001010000000000000515BI0100001442
33113.11One lift passenger MRL 8 passenger 544 kgs of V3f Gearless with Automatic centre opening doors in stainless steel hairline finish upto 5 stops without machine roomBI01010001010000000000000515BI01000014431each

AI Tender Summary

OUR REF NO 26815890
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 12-03-2021
Authority
Authority Name IMPACT Kerala Limited
Work Description Construction Of Ramanattukara Municipal Office Building - Retender Building Including Civil , Plumbing , Electrical Works , Etc
Basic Detail
Tender No IKL/BLDG/2021/1
Bidding Type Tender
Location
City Ramanattukara
State Kerala
Key Dates
Publish Date 03 Feb 2021
Submission Date 12 Mar 2021
Open Date 15 Mar 2021
Finance
Tender Value Ref. Documents
Tender Fee 17700
EMD 5 Lakhs
Exemption Not Available
Document List
31321870-4013-47CD-A631-94089DF4F241.html
BOQ_582994.xls
RetenderNotice.pdf
RamanattukaraDrawings.pdf
SBDRamanattukara.pdf
PrebidMinutes.pdf
Tendernotice_1.pdf
PaymentDeclaration.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 03, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 12, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 15, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

31321870-4013-47CD-A631-94089DF4F241.html

xls

BOQ_582994.xls

pdf

RetenderNotice.pdf

pdf

RamanattukaraDrawings.pdf

pdf

SBDRamanattukara.pdf

pdf

PrebidMinutes.pdf

pdf

Tendernotice_1.pdf

pdf

PaymentDeclaration.pdf