Construction Of General Nursing And Mid Wifery Training School ( Gnm ) Doda Electrification Work ( Contract No 49 )
Tender Value
27.69 Lakhs
Estimated cost
Bid Submission
10 Feb 2021
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
DODA → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of General Nursing And Mid Wifery Training School ( Gnm ) Doda Electrification Work ( Contract No 49 )
BOQ
| Name of Work: Construction of General Nursing & Mid wifery Training School (GNM) Doda( Electrification Work). Contract No. 49 | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A | 210 | Nos. | |
| 2 | 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A This Excludes GI Box & PVC Conduit,bends, junction box etc | 165 | Nos. | |
| 3 | 3 | supply and fixing of 5 inch dia Fan Box / concealed box with round sheet cover for covering the base and bottom and dual painted with red oxide(LMR) Make:- Anchor/Indoasian/havells | 52 | Nos. | |
| 4 | 4 | Providing Installation testing and commissioning of Ceiling Fans of approved brands with connections etc as required (LMR)Make:- Anchor/Indoasian/havells 0r equivalent | 109 | Nos. | |
| 5 | 5 | Supply & Fixing of additional Fan rods(LMR)Make:- Anchor/havells | 109 | Nos. | |
| 6 | 6 | Supplying and fixing two module Stepped type electronic Fan Regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | 109 | Nos. | |
| 7 | 7 | Supply,installation,testing and commissioning of Ceiling LED Panel type 15 watt day milky fitting with connections as required (LMR) Make:- Philips/ Bajaj /CG | 19 | Nos. | |
| 8 | 8 | Supply & installation, of Conciel Box for LED Panel as required (LMR) Make:- Anchor/havells /CG | 8 | Nos. | |
| 9 | 9 | Supplying and fixing of 20 watt LED fiiting 4 feet long wall /surface mounted including connections etc as required ( LMR) Make:- Anchor/ CG /havells | 198 | Nos. | |
| 10 | 10 | Providing and fixing of Brass Batten Holder/ Angle holder including connections as required. | 8 | Nos. | |
| 11 | 11 | Providing and fixing of 9 watt LED Bulb ( LMR) Make:- Anchor/orient/havells 0r equivalent | 8 | Nos. | |
| 12 | 12 | Providing and fixing of Decorative wash Basin Light and complete with 9 watt LED Bulb.(LMR)Make:- Philips/ Bajaj /CG | 4 | Nos. | |
| 13 | 13 | Providing and fixing wall Bracket Light decorative type surface mounted and complete with 9 watt LED Bulb.(LMR) Make:- Philips/ Bajaj /CG | 6 | Nos. | |
| 14 | 14 | Supply & Installation of Bulk Head Lights including connections,testing commissioning etc as required(LMR) Make:- Anchor/ CG /havells or equivalent | 5 | Nos. | |
| 15 | 15 | Supply & Installation of Wall Fans including connections,testing commissioning etc as required(LMR) Make:- Anchor/ CG /havells | 8 | Nos. | |
| 16 | 16 | Supply & Installation of Exhaust Fans in the existing opening including connections,testing commissioning etc as required(LMR) Make:- Anchor/ luminous/havells | 14 | Nos. | |
| 17 | 17 | Providing ,installation,testing and Commissioning of 70 watt LED Flood light with GI Pipe with connection etc as required Make:- Philips/ Bajaj /CG or equiv | 5 | Nos. | |
| 18 | 18 | Supply & drawing 2 pair0.5 sqmm FR PVC Insulated annealed copper conductor,unarmoured telephone cable in the existing surface/recessed steel/ PVC Conduit as required 2 Pair | 190 | Rmt | |
| 19 | 19 | Supplying and fixing of Telephone Socket outlet modular Switch/ Socket on the existing Modular Plate and switch box including connections but excluding modular plateas required | 4 | Nos. | |
| 20 | 20 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required | |||
| 21 | 20.1 | 5/6 A switch | 4 | Nos. | |
| 22 | 20.2 | 3 pin 5/6 A socket outlet | 4 | Nos. | |
| 23 | 20.3 | TV antenna socket outlet | 4 | Nos. | |
| 24 | 21 | Supply & drawing co axial TV Cable RG 6 grade o.7 mm solid copper conductor PE insulated, shielded with fine tinned copper brand 7 protected with PVC sheath in the existing surface/recessed steel/PVC Conduit as required | 110 | Rmt | |
| 25 | 22 | supply and fixing of modular D-link Computer socket on modular zinc passivated box of 2 module (Make:D-Link) (LMR) | 6 | Nos. | |
| 26 | 23 | Providing & Laying D-Link Cat-6 Computer wire in existing Conduit (LMR)(Make:D-Link | 265 | Rmt | |
| 27 | 24 | Suppl , fixing, testing & commissioning of Call Bell which includes connections etc | 2 | Nos. | |
| 28 | 25 | Supply and fixing of Ceiling rose on the existing junction box/wooden box including connections as required | 45 | Nos. | |
| 29 | 26 | Supply and fixing Modular Blanking Plate on the existing modular plate and switch box excluding modular plateas required | 40 | Nos. | |
| 30 | 27 | Supplying laying & making outdoor connections including aluminium lugs and other jointing materials for 3.5 X 120 sqmm LT Power Cable ,Almunium Conductor (LMR) Make:- Gloister/ CCI/havells | 100 | Rmt | |
| 31 | 28 | Supply ,instalation,fabrication and commissioning of Low voltage Sub Main Panel on 415 volts 3 phase 50 htzs of 2mm thick CRCA / Sheet of powder size 3X4 rft . a)Providing and fixing od 300 amp TPN A1.Bus bar with required nos of thimbles etc b)250 amp 4 pole MCCB with breaking capacity c)100 amp 4 pole change over switch d)63 amp SPN (10 nos) e)VSS meter/switch f) ASS meter/ switch Make:- HaGer/Siemens/Automatic electric /ABB | 1 | Nos. | |
| 32 | 29 | Supply & Fixing of following size of medium class PVC Conduits along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduits as required Make:- M/S Polycab/AKG/finolexor equiva | |||
| 33 | 29.1 | 25 mm | 1860 | Rmt | |
| 34 | 29.2 | 40 mm | 260 | Rmt | |
| 35 | 30 | Supplying and fixing of following way horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | |||
| 36 | 30.1 | 8 way (4 + 24) double door | 5 | Nos. | |
| 37 | 31 | Supplying and fixing following rating, four pole,TPN, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||
| 38 | 31.1 | 63 Amp | 5 | Nos. | |
| 39 | 32 | Supplying and fixing of 5 amps to 32 amps rating 240/415 volts \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required of Approved Brand. Single Pole | 194 | Nos. | |
| 40 | 33 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Make :- /Anchor/finolex/polycab or Equivalent | |||
| 41 | 33.1 | 2 x 2.5 Sqmm + 1 x 2.5 sqmm | 2265 | Metres | |
| 42 | 33.2 | 2 x 4 Sqmm + 1 x 4 sqmm | 3045 | Metres | |
| 43 | 33.3 | 2 x 6 Sqmm + 1 x 6 sqmm | 665 | Metres | |
| 44 | 33.4 | 4 x 16 Sqmm + 2 x 6 sqmm earth wire | 325 | Metres | |
| 45 | 34 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. | |||
| 46 | 34.1 | 15/16 A switch | 114 | Nos. | |
| 47 | 34.2 | 6 pin 15/16 A socket outlet | 114 | Nos. | |
| 48 | 35 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required | |||
| 49 | 35.1 | 4 Module (125mmX75mm) | 114 | Nos. | |
| 50 | 36 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. | |||
| 51 | 36.1 | 4 Module | 114 | Nos. | |
| 52 | 37 | Supplying and fixing suitable size 3 Module GI Box with modular plate & cover infront including providing 3 pin 5/6 A modular switch /socket including connections etc. as reqd. | 20 | Nos. | |
| 53 | 38 | Supplying and fixing following 5 pin 5/6 A modular switch /socket on the existing modular plate & swich box including connections etc. as reqd. | 84 | Nos. | |
| 54 | 39 | Providing and fixing of 2 way AC Box with MCB mounting and connections etc as required. (LMR)Make:- Anchor/ CG /havells 0r equivalent | 10 | Nos. | |
| 55 | 40 | Providing & fixing of 25mm X 5mm Copper strip on surface or in recess for connections etc as required | 70 | Mtr | |
| 56 | 41 | Earthing with copper earth plate 600mm X 600mm X 3mm thick including accessories and providing massonary enclosure with cover plate having locking arrangemets and watering pipe of 2.7 mtr long etc with Charcoal / coke salt as required Make:- Anchor/Indoasian/havells 0r equivalent | 3 | Nos. |
AI Tender Summary
Tender Timeline
Feb 01, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 10, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 11, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender