| 1 | 1 | Excavating in post holes (or similar holes) each not exc 0.5 Cum in any type of soil, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc. 25 cm thick watering and well ramming and removing surplus soil to a distance not exc 50m and making good surface complete all as specified and directed. | | 43 | Nos |
|---|
| 2 | 2 | Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10sqm on plan and not exc 1.5m in depth and getting out in any type of soil complete all as specified and directed. | | 17.31 | CUM |
|---|
| 3 | 3 | Returning ,filling in soils including spreading leveling, watering and well ramming in layers not exc 25 Cm thick complete all as specified and directed | | 3.9 | CUM |
|---|
| 4 | 4 | Removing excavated soils to a distance not exc 50m lead and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. | | 13.41 | CUM |
|---|
| 5 | 5 | M & L PCC in foundation M-10 (Nominal Mix) using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and directed. | | 6.4 | CUM |
|---|
| 6 | 6 | S & F Rolling mild steel work or other steel section as in post and struts in fencing, straight portion, drilled and countersunk for balusters running bars including embeding in concrete and screwing etc. including securing bolts, cutting tops to shape as directed, drilling holes, notching for wire, etc.: flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 to complete all as specified and directed. | | 819.51 | KG |
|---|
| 7 | 7 | S&F Mild steel bars 10mm dia and over, as in line wires, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with MS wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to complete all as specified. \n | | 360.1 | KG |
|---|
| 8 | 8 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming Fe-290 Gde E-165 to complete all as specified. | | 20 | KG |
|---|
| 9 | 9 | M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on steel and iron surfaces of any decription including prepration of surface complete all as specified and directed. \n | | 190.91 | Sqm |
|---|
| 10 | 10 | S&F of chainlink MS galvanised fencing any mesh size (approx. Size 100x100x4.7mm) and type to any type of standards, rails, straining bolts etc. including provision of binding wire to complete all as specified. | | 429.65 | KG |
|---|
| 11 | 11 | S&F galvanised 2 strand steel barbed wire 2.24mm dia, barbed with 2.0mm dia barbs at 75mm spacing and straining and fixing to any standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc as directed (each line wire to be measured) complete all as specified and directed.\n | | 5.12 | 100 RM |
|---|
| 12 | 12 | M&L Brick work brick having crushing strength not less than 75Kg/sqcm, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 complete all as\nspecified and as directed.\n | | 16.19 | CUM |
|---|
| 13 | 13 | M&L Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete, surface finished even and smooth without using extra cement, complete all as specified and as directed.\n | | 135.6 | Sqm |
|---|
| 14 | 14 | M&L for cement concrete 1:2:4 type B1 using 20mm graded curshued stone aggregate as in lintels upto 1.5m clear span, cills,steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, and the like including necessary form work, weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.\n | | 6.91 | CUM |
|---|
| 15 | 15 | M&L for two coats of cement base paint over a coat of primer on walls including preparation of new plastered/unplastered surface of walls complete all as specified and directed.\n | | 60 | SQM |
|---|
| 16 | 16 | M&L for Steel gate 5.5m wide and 2.4m high with 2 nos RCC pillers complete all as specified, directed and shown on Drg no CEPZ/STD-107/09 sheet no 1/1 dt 16 Mar 2009 \n | | 2 | Each Job |
|---|
| 17 | 17 | M&L for Steel gate 1.2 m wide and 1.5 m high with 2 nos RCC pillers complete all as specified, directed and shown on Drg no CEPZ/STD-096/08 sheet no 1R/1 dt 26 Nov 2008\n | | 1 | Each Job |
|---|