}

Micro Sprinkler System Of 2 Ha Capacity ( 5 Nos ) And Installation Of Solar Photovoltaic System Of 2 Hp Capacity ( 6 Nos ) At Dhara Watershed At Mouza Padulara Jl No 60 Within Indpur Block Under Bankura (A-I) Division Under Matir Shristi Programme, Mouza Padulara JL No 60 within Indpur Block-West Bengal

Water Resources Department-WRD has published Micro Sprinkler System Of 2 Ha Capacity ( 5 Nos ) And Installation Of Solar Photovoltaic System Of 2 Hp Capacity ( 6 Nos ) At Dhara Watershed At Mouza Padulara Jl No 60 Within Indpur Block Under Bankura (A-I) Division Under Matir Shristi Programme. Submission Date for this Tender is 10-02-2021. Solar Power Plants Tenders in Mouza Padulara JL No 60 within Indpur Block West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

26788314
Micro Sprinkler System Of 2 Ha Capacity ( 5 Nos ) And Installation Of Solar Photovoltaic System Of 2 Hp Capacity ( 6 Nos ) At Dhara Watershed At Mouza Padulara Jl No 60 Within Indpur Block Under Bankura (A-I) Division Under Matir Shristi Programme
Open Tender
Indian
West Bengal
Mouza Padulara JL No 60 within Indpur Block
10-02-2021

Tender Details

Micro Sprinkler System Of 2 Ha Capacity ( 5 Nos ) And Installation Of Solar Photovoltaic System Of 2 Hp Capacity ( 6 Nos ) At Dhara Watershed At Mouza Padulara Jl No 60 Within Indpur Block Under Bankura ( A-I ) Division Under Matir Shristi Programme

Key Value

Document Fees
Refer document
EMD
INR 37930.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Micro sprinklar system of 2 Ha capacity ( 5 nos ) and Installation of Solar Photovoltaic system of 2 HP Capacity ( 6 nos ) at Dhara watershed at Mouza Padulara JL No 60 within Indpur Block under Bankura (A-I) Division under Matir Shristi Programme.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Micro Spriklar portion for 5 unit for 2 Ha PVCpipe 75 mm x 04 kgf/cm2 VCpipe 75 mm x 04 kgf/cm2 BI01010001010000000000000515BI0100001113 500 meter
2 2 PVC pipe 63 mm x 04 kgf/cm2 BI01010001010000000000000515BI0100001114 750 Metre
3 3 PVC/PE Tube 20 mm Class-II BI01010001010000000000000515BI0100001115 20000 Metre
4 4 MI Spr 16 to 110 lph BI01010001010000000000000515BI0100001116 4000 No
5 5 Stake for Sprinkler Set BI01010001010000000000000515BI0100001117 4000 No
6 6 PVC Control Valve 75 mm BI01010001010000000000000515BI0100001118 5 No
7 7 PVC Control Valve 63 mm BI01010001010000000000000515BI0100001119 15 No
8 8 Flush Valve 63 mm BI01010001010000000000000515BI0100001120 5 No
9 9 PVC AIR RELEASE VALVE MINI1 " BI01010001010000000000000515BI0100001121 5 No
10 10 PVC Non Return Valve 63 mm BI01010001010000000000000515BI0100001122 5 No
11 11 BUTTERFLY VALVE C.I. 65 MM -2.5” BI01010001010000000000000515BI0100001123 5 No
12 12 Metal Screen Filter 30 m3/hr 2.5'' BI01010001010000000000000515BI0100001125 5 No
13 13 G.I. BYPASS&ARV M/F 2.5"X1.5"X1" BI01010001010000000000000515BI0100001126 5 No
14 14 Ventury Assembly Complete 2’’ Plastic BI01010001010000000000000515BI0100001127 5 No
15 15 Fittings and Accessories @ 5% of Sl no 1 to 14 1 Item
16 16 INSTALLATION OF SPV MODULE AND PUMP FOR SPRINKLER OPERATION (2 HP) 6 UNIT Solar Module: Supply , transport , installation and commissioning of ISI marked as per IS 14286 and IEC 61853(1), 61730(1&2), 61710 certified Solar Module of Multicrystaline/Monocrystalline/ Monocrystalline PERC/bifacial cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity 3.2/4.0 mm tempered glass , framed in anodized aluminium frame .The power output of individual PV modules used in the PV array, under STC, should be a minimum of 300 Watt peak, with adequate provision for measurement tolerances.Modules supplied with the SPV system should have warranty for output wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be supplied. a) For 2 HP Off-grid Solar Water Pumping System with polycrystalline SPV modules - 2300-2400 Wp. 14400 Wp
17 17 Module Mounting Structure ( For 2HP, 3HP and 5HP Solar Water Pumping System): Supply , transportation & installation of G.I manual tracking structure made of MS hollow sections, pipes, plates, angles etc as per IS 1161/1239, 1079/2062, to hold min 300 Wp SPV Module as per drawing and specification of MNRE . The steel structure is to be protected with minimum 80 micron galvanisation(hot dip) and provided with dual axis manual tracking arrangement three times in a day and seasonal tilting are to be regulated to face the sun optimally. The weight of the Module Mounting Structure holding 4 Modules should not be less than 195Kgs, holding 6 Modules should not be less than 210 Kg and holding 8 Modules should not be less than 245 Kg. (214.13Kg for 6 module structure) 1260 kg
18 18 Foundation of Module Mounting Structure: Suitable and stable Reinforced Cement Concrete foundation for dual axis manual tracking SPV Module structure as per approved drawing. a) For 4/6 module structure having a maximum capacity of 1950 Wp 6 each
19 19 Power conditioning unit with IP54 enclosure :\nSupply , transport , installation and commissioning of IP 54 protected enclosured Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 60068-2-Environment Standard , safety standard suitable for 3 Phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology, to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure. Inverter should have protection against Dry run, Over current, Under current, Over voltage, Under voltage, Short circuit etc. System should be able to run at low sunshine and minimum 7 to 8 hours a day run should be possible during normal sunshine.condition. Inverter should have option to auto start for any short trip off due to low light/ cloudy situation except for dry run. Inverter should be provided with a display to show the various parameter by the user such as Voltage, Current, Solar panel DC voltage, Inverter IGBT temperature, Out put AC voltage, Output frequency, Pump flow (direct or calculated method), Irradiation etc . The system should store the data at a set interval, be capable to transfer it to external storage device and support communication of its operational parameters and logs over Modbus protocol . It should also monitor and save total run time, total water pumped etc . There should be provision for interfacing GPRS based data transmission. c) For 2 HP capacity Pump-motor set 6 set
20 20 Cable and Accessories :\nSupplying, fitting and fixings of UV rated Copper Cable laid inside HDPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc.\ni. 4.0 Sq mm single core multi studs - 10 Mtrs (Minimum)\nii. 6.0 Sq mm single core multi struds -5 Mtrs (Minimum)\niii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etc. c) For 2 HP per structure 6 each
21 21 Earthing: Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:\n By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.\n 6 each set
22 22 Lightning protection (Pole mounted): Lightning protection with 3" X 1.5" G.I pipe of (6+1) mts height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top . Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts, including connection to earth electrodes with 25 X 6mm G.I strip. (Provision of one lightning protection for each scheme as per drawing) 6 each
23 23 Supply and installation of 3 phase electromotor pump-motor set suitable for Solar operation covering 5 years warranty for the following conditions including loading, unloading, transportation etc.:- c) 2 HP ISI marked 3 phase 415 V Pump-Motor set having discharge at required head as below:- ii) Submersible Pump-motor set for LDTW ISI marked as per IS: 8034 with discharge of 7.5 Lps- 5.83 Lps at 30 mts.-40 mts. total head with cable, cover plate, Socket, Flanged Nipple, Rubber Insertion, Nuts& bolts and all other accessories including transportation of Bend, Column Pipes, cable, sluice valve, lay flat hose pipe etc. from Deptt. Store to site within 100km. 6 set
24 24 Testing and commissioning of scheme after completion of all work 6 item
25 25 Comprehensive maintenance charges for 4 years beyond 1 year warranty period (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme in operation without lapse of time) c) For 2 HP both for Submersible & Surface pump Note:\nTotal comprehensive maintenance charge is to be withheld in addition to Securirty Deposit . Security Deposit will be released after expiry of warranty period of 1 year & Comprehensive maintenance charges will be released @ Rs.0.75 per Wp per year at the end of each maintenance period i.e.at the end of 2nd year, 3rd year, 4th year, 5th year. In case the “Bidder” does not provide service during the warranty & comprehensive maintenance period, the amount so held up will be forfeited 14400 Wp
26 26 Insurance @ 2% for Item No. 16, 19 and 23 for a period of 5 years. Note:2\nIst year's Insurance charge is to be paid on production of Original Receipt of premium payment. Remaining 4 years Insurance payment is to be withheld which will be released during 2nd, 3rd , 4th & 5th year on production of Original Receipt of premium payment. 1 Item
27 27 Add GST @12 % of Total of item no 1 to 26 = Rs 1676528.25 x .012 = Rs 201183.39 1 item
28 28 Add CESS @1 % of Total of item no 1 to 27 = Rs 1877711.60 x .01= Rs 18777.11 1 item
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail