Renovation And Up Gradation Of Community Centre And Construction Of Multipurpose Indoor Hall , Play Ground Development With Provision Of Gallery At Central Township , Kaliapani In The District Of Jajpur .
Tender Overview
Project Description
Renovation And Up Gradation Of Community Centre And Construction Of Multipurpose Indoor Hall , Play Ground Development With Provision Of Gallery At Central Township , Kaliapani In The District Of Jajpur .
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-Feb-2021 | CORRIGENDU TO TECHNICAL BID | Technical Bid | 19-Feb-2021 |
BOQ
| Name of Work: Renovation and up gradation of Community Centre and Construction of Multipurpose Indoor Hall, Play ground development with provision of Gallery at Central Township, Kaliapani in the district of Jajpur. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Civil Works | BI01010001010000000000000515BI0100001112 | ||
| 2 | 1.01 | Earth work in excavation in all kinds of soil (Ordinary, hard soil & stoney earth soil ) for foundation trenches within 50m. Initial lead and 1.5m initial lift including rough dressing and beaking clods to maximum 5 cm to 7 cm and laying in layers not exceeding 0.3 m in depth and as per direction of EIC/ Architect. | BI01010001010000000000000515BI0100001113 | 4010.86 | Cum |
| 3 | 1.02 | Cutting in disintegrated rock not requiring blasting to be removed by pick axes and crow bars and depositing materials within 50m initial lead and 1.5m initial lift including rough dressing as per direction and specification of the department including stacking the useful materials separately as ordered including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with all leads and lifts, T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, designing including cost of all labour, T&P etc. as required for the work complete as per direction of EIC / Architect. | BI01010001010000000000000515BI0100001114 | 341.9 | Cum |
| 4 | 1.03 | Filling foundation trenches and plinth with excavated earth including laying the earth in layers not exceeding 23.5cm (9”) thick ramming and watering with all leads and lifts including cost of all labour, T&P etc. complete as directed by the Engineer-in-charge. | BI01010001010000000000000515BI0100001115 | 183.24 | Cum |
| 5 | 1.04 | Supplying, filling in foundation and plinth with sand including watering and ramming with cost, conveyance, royalties of sand with labour and T&P required for the work etc. complete as per direction of EIC and Architect. (Measurement will be taken on finished compacted section only). GROUND FLOOR | BI01010001010000000000000515BI0100001116 | 2392.29 | Cum |
| 6 | 1.05 | Providing & laying Plain Cement concrete (PCC ) of proportion (1:4:8) in foundation and floors using 4cm (1½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties and ,es of all materials with all labour, cess and T&P required for the work etc. complete in all respect as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001117 | 41.14 | Cum |
| 7 | 1.06 | Providing & laying Plain Cement concrete (PCC ) of proportion (1:3:6) in foundation and floors using 4cm (1½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties and ,es of all materials with all labour, cess and T&P required for the work etc. complete in all respect as per direction of EIC and Architect. | BI01010001010000000000000515BI0100001118 | 387.74 | Cum |
| 8 | 1.07 | Providing & laying Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties of all materials with labour, cess and T&P etc. required for the work complete as per direction of EIC and Architect. GROUND FLOOR | BI01010001010000000000000515BI0100001119 | 6.86 | Cum |
| 9 | 1.08 | Providing & laying Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties of all materials with labour, cess and T&P etc. required for the work complete as per direction of EIC and Architect. FIRST FLOOR | BI01010001010000000000000515BI0100001120 | 11.37 | Cum |
| 10 | 1.09 | R.C.C. work of Grade- M 25 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position. Foundation & bases of column (Ground Floor) | BI01010001010000000000000515BI0100001121 | 387.56 | Cum |
| 11 | 1.1 | R.C.C. work of Grade- M 25 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position. Plinth Beam | BI01010001010000000000000515BI0100001122 | 39.32 | Cum |
| 12 | 1.11 | R.C.C. work of Grade- M 25 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position. Pedestal & Columns (GROUND FLOOR) | BI01010001010000000000000515BI0100001123 | 58.07 | Cum |
| 13 | 1.12 | R.C.C. work of Grade- M 25 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position. Roof Beam (GROUND FLOOR) | BI01010001010000000000000515BI0100001124 | 108.42 | Cum |
| 14 | 1.13 | R.C.C. work of Grade- M 25 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position. Lintel (GROUND FLOOR) | BI01010001010000000000000515BI0100001125 | 5.03 | Cum |
| 15 | 1.14 | R.C.C. work of Grade- M 25 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position. Chajja (GROUND FLOOR) | BI01010001010000000000000515BI0100001126 | 33.87 | Sqm |
| 16 | 1.15 | R.C.C. work of Grade- M 25 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position Roof slabs (GROUND FLOOR) | BI01010001010000000000000515BI0100001127 | 175.02 | Cum |
| 17 | 1.16 | R.C.C. work of Grade- M 25 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position.in Staircase (GROUND FLOOR) | BI01010001010000000000000515BI0100001128 | 148.06 | Cum |
| 18 | 1.17 | R.C.C. work of Grade- M 25 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position. in RCC wall (GROUND FLOOR) | BI01010001010000000000000515BI0100001129 | 23.59 | Cum |
| 19 | 1.18 | R.C.C. work of Grade- M 25 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position. in Columns FIRST FLOOR | BI01010001010000000000000515BI0100001130 | 18.2 | Cum |
| 20 | 1.19 | R.C.C. work of Grade- M 25 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position. in Roof Beam FIRST FLOOR | BI01010001010000000000000515BI0100001131 | 28 | Cum |
| 21 | 1.2 | R.C.C. work of Grade- M 25 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position. in Lintel FIRST FLOOR | BI01010001010000000000000515BI0100001132 | 4.63 | Cum |
| 22 | 1.21 | R.C.C. work of Grade- M 25 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position. Chajja FIRST FLOOR | BI01010001010000000000000515BI0100001133 | 21.37 | Sqm |
| 23 | 1.22 | R.C.C. work of Grade- M 25 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position. Roof slabs FIRST FLOOR | BI01010001010000000000000515BI0100001134 | 49.53 | Cum |
| 24 | 1.23 | R.C.C. work of Grade- M 25 in following works using 20mm size & down graded hard black crusher broken granite stone chips of approved quality from approved quarry in specified proportion including centering & shuttering,hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect as per the direction of engineer incharege but excluding the cost and conveyance of HYSD rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position. in Staircase FIRST FLOOR | BI01010001010000000000000515BI0100001135 | 3.53 | Cum |
| 25 | 1.24 | Reinforcement for RCC work including straightening, cutting, bending, placing in position HYSD and binding all complete. lifting and placing in position as per design complete including cost of bars , binding wires , including cost of all materials, labour, conveyance, loading and unloading,, royalties, sundries, tools and plants, etc. complete as per the direction of the Engineer-in-charge. (linear measurement will be taken and quantity will be calculated on standard weight for all heights)-Thermo Mechanically Treated bars GROUND FLOOR | BI01010001010000000000000515BI0100001136 | 100.306 | Ton |
| 26 | 1.25 | Reinforcement for RCC work including straightening, cutting, bending, placing in position HYSD and binding all complete. lifting and placing in position as per design complete including cost of bars , binding wires , including cost of all materials, labour, conveyance, loading and unloading,, royalties, sundries, tools and plants, etc. complete as per the direction of the Engineer-in-charge. (linear measurement will be taken and quantity will be calculated on standard weight for all heights)-Thermo Mechanically Treated bars FIRST FLOOR | BI01010001010000000000000515BI0100001137 | 12.289 | Ton |
| 27 | 1.26 | Providing Brick work with Fly ash bricks 25cm x 12cm x 8cm size having crushing strength not less than 75 kg/cm2 with dimensional tolerance +/ - 2 percent in cement mortar (1:6) ( 1 cement: 6 sand), with all necessary projection, splay cutting, circular moulding, corbelling, etc., including cost of all materials, labour, conveyance, loading ,and unloadining, royalties, scaffolding, watering, curing, sundries, tools and plants, etc., as per the direction of the Engineer-in-charge in Foundation & Plinth | BI01010001010000000000000515BI0100001138 | 311.95 | Cum |
| 28 | 1.27 | Providing Brick work with Fly ash bricks 25cm x 12cm x 8cm size having crushing strength not less than 75 kg/cm2 with dimensional tolerance +/ - 2 percent in cement mortar (1:6) ( 1 cement: 6 sand), with all necessary projection, splay cutting, circular moulding, corbelling, etc., including cost of all materials, labour, conveyance, loading ,and unloadining, royalties, scaffolding, watering, curing, sundries, tools and plants, etc., as per the direction of the Engineer-in-charge.in Superstructure GROUND FLOOR | BI01010001010000000000000515BI0100001139 | 177.72 | Cum |
| 29 | 1.28 | Providing Brick work with Fly ash bricks 25cm x 12cm x 8cm size having crushing strength not less than 75 kg/cm2 with dimensional tolerance +/ - 2 percent in cement mortar (1:6) ( 1 cement: 6 sand), with all necessary projection, splay cutting, circular moulding, corbelling, etc., including cost of all materials, labour, conveyance, loading ,and unloadining, royalties, scaffolding, watering, curing, sundries, tools and plants, etc., as per the direction of the Engineer-in-charge.in Superstructure FIRST FLOOR | BI01010001010000000000000515BI0100001140 | 126.58 | Cum |
| 30 | 1.29 | Providing Brick work with Fly ash bricks 25cm x 12cm x 8cm size having crushing strength not less than 75 kg/cm2 with dimensional tolerance +/ - 2 percent in cement mortar(1:4) ( 1 cement: 4 sand) including watering and curing for the required period, imersing the bricks in vat before 6 hours of use, including cost of all material, labour, conveyance, loading and unloading, royalties, scaffolding, watering, curing, sundries, tools plants, etc., complete as per the direction of the Engineer-in-charge in Superstructure GROUND FLOOR | BI01010001010000000000000515BI0100001141 | 15.98 | Cum |
| 31 | 1.3 | Providing Brick work with Fly ash bricks 25cm x 12cm x 8cm size having crushing strength not less than 75 kg/cm2 with dimensional tolerance +/ - 2 percent in cement mortar(1:4) ( 1 cement: 4 sand) including watering and curing for the required period, imersing the bricks in vat before 6 hours of use, including cost of all material, labour, conveyance, loading and unloading, royalties, scaffolding, watering, curing, sundries, tools plants, etc., complete as per the direction of the Engineer-in-charge in Superstructure FIRST FLOOR | BI01010001010000000000000515BI0100001142 | 13.61 | Cum |
| 32 | 1.31 | Providing 16 mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) with portland slag cement (PSC) finished smooth to inside rough surface of brick masonry walls after racking out joints including watering and curing rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and ,es of all materials and cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer in charge. (Inside) at GROUND FLOOR | BI01010001010000000000000515BI0100001143 | 981.75 | Sqm |
| 33 | 1.32 | Providing 16 mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) with portland slag cement (PSC) finished smooth to inside rough surface of brick masonry walls after racking out joints including watering and curing rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and ,es of all materials and cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer in charge. (Inside) at FIRST FLOOR | BI01010001010000000000000515BI0100001144 | 815.51 | Sqm |
| 34 | 1.33 | Providing 12 mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) with portland slag cement (PSC) finished smooth to inside rough surface of brick masonry walls after racking out joints including watering and curing rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and ,es of all materials and cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer in charge. (Outside) at GROUND FLOOR | BI01010001010000000000000515BI0100001145 | 3898.42 | Sqm |
| 35 | 1.34 | Providing 12 mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) with portland slag cement (PSC) finished smooth to inside rough surface of brick masonry walls after racking out joints including watering and curing rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and ,es of all materials and cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer in charge. (Outside) at FIRST FLOOR | BI01010001010000000000000515BI0100001146 | 562.69 | Sqm |
| 36 | 1.35 | Providing 6mm thick plaster in C.M. (1:4) over ceiling, chajja, loft, staircase, column, beams and walls after removing the false if necessary and close deep chipping including rounding of the corners, recess and roughening concrete surface where necessary, watering and curing, finished smooth over R.C.C. surface, including cost, conveyance, royalty, ,es of all materials, cost of all labour, T&P etc. complete as per direction of the Engineer-in-charge. GROUND FLOOR | BI01010001010000000000000515BI0100001147 | 483.29 | Sqm |
| 37 | 1.36 | Providing 6mm thick plaster in C.M. (1:4) over ceiling, chajja, loft, staircase, column, beams and walls after removing the false if necessary and close deep chipping including rounding of the corners, recess and roughening concrete surface where necessary, watering and curing, finished smooth over R.C.C. surface, including cost, conveyance, royalty, ,es of all materials, cost of all labour, T&P etc. complete as per direction of the Engineer-in-charge. FIRST FLOOR | BI01010001010000000000000515BI0100001148 | 125.36 | Sqm |
| 38 | 1.37 | Fixing Kota tiles in floors treads or steps and landing on 25mm thick cement mortar (1:1) (1cement : 1 course and) and filling joints with of approved quality including cost, conveyance, taxes, cost of all labour etc. complete as per direction of EIC/Architect. GROUND FLOOR | BI01010001010000000000000515BI0100001149 | 392.98 | Sqm |
| 39 | 1.38 | Providing Kota stone 16mm thick in dado of approved quality, colour and size in dado, riser of steps and dado of landings in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. GROUND FLOOR | BI01010001010000000000000515BI0100001150 | 98.48 | Sqm |
| 40 | 1.39 | Providing vitrified tile flooring using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13756 of 1200mm x 1200mm / 1200mm x 1800mm Colour & Printed Series (homogeneous) of approved quality of Somany / Kajaria / Asian / Johnson or equivalent in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. GROUND FLOOR | BI01010001010000000000000515BI0100001151 | 612.91 | Sqm |
| 41 | 1.4 | Providing vitrified tile flooring using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13756 of 1200mm x 1200mm / 1200mm x 1800mm Colour & Printed Series (homogeneous) of approved quality of Somany / Kajaria / Asian / Johnson or equivalent in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. FIRST FLOOR | BI01010001010000000000000515BI0100001152 | 567.63 | Sqm |
| 42 | 1.41 | Providing vitrified tile in dado/ skirting using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13756 of 1200mmx1200mm or 1200mmx1800mmColour & Printed Series (homogeneous) of approved quality of Somany / Kajaria / Asian / Johnson or equivalent in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. GROUND FLOOR | BI01010001010000000000000515BI0100001153 | 75.93 | Sqm |
| 43 | 1.42 | Providing vitrified tile in dado/ skirting using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13756 of 1200mmx1200mm or 1200mmx1800mmColour & Printed Series (homogeneous) of approved quality of Somany / Kajaria / Asian / Johnson or equivalent in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. FIRST FLOOR | BI01010001010000000000000515BI0100001154 | 52.06 | Sqm |
| 44 | 1.43 | Supplying , fitting and Fixing full body glazed Matt vitrified tile flooring using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13756 of 1200mm x 1200mm of approved quality of Somany / Kajaria or equivalent in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. Ground floor | BI01010001010000000000000515BI0100001155 | 220.58 | Sqm |
| 45 | 1.44 | Supplying , fitting and Fixing full body glazed Matt vitrified tile flooring using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13756 of 1200mm x 1200mm of approved quality of Somany / Kajaria or equivalent in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. First floor | BI01010001010000000000000515BI0100001156 | 23.57 | Sqm |
| 46 | 1.45 | Supplying , fitting and Fixing full body glazed Matt vitrified tile in dado/ skirting using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13756 of 600mmx600mm of approved quality of Somany / Kajaria or equivalent in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge.Ground floor | BI01010001010000000000000515BI0100001157 | 17.42 | Sqm |
| 47 | 1.46 | Supplying , fitting and Fixing full body glazed Matt vitrified tile in dado/ skirting using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13756 of 600mmx600mm of approved quality of Somany / Kajaria or equivalent in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. First floor | BI01010001010000000000000515BI0100001158 | 21.99 | Sqm |
| 48 | 1.47 | Providing Granite stone prepolished 20mm thick of area above 0.40 Sqm in flooring of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. GROUND FLOOR | BI01010001010000000000000515BI0100001159 | 179.83 | Sqm |
| 49 | 1.48 | Providing Granite stone prepolished 20mm thick of area above 0.40 Sqm in flooring of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. FIRST FLOOR | BI01010001010000000000000515BI0100001160 | 57.19 | Sqm |
| 50 | 1.49 | Providing Granite stone prepolished 10mm thick in dado of approved quality, colour and size in dado, riser of steps and dado of landings in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.GROUND FLOOR | BI01010001010000000000000515BI0100001161 | 25.4 | Sqm |
| 51 | 1.5 | Providing Granite stone prepolished 10mm thick in dado of approved quality, colour and size in dado, riser of steps and dado of landings in all floors at all height on 12mm thick bed of cement mortar of mix (1:3) with screened and washed sharp sand for mortar and grouted with neat white cement slurry jointing the tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.FIRST FLOOR | BI01010001010000000000000515BI0100001162 | 11.03 | Sqm |
| 52 | 1.51 | Providing edge moulding to 18 mm thick granite stone counters, Vanities, steps etc., including machine polishing to edge to give high gloss finish including making three nos of groove over tread etc. complete including cost, coveyance, loading and unloading and ,es of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge. GROUND FLOOR | BI01010001010000000000000515BI0100001163 | 247.06 | Mtr |
| 53 | 1.52 | Providing edge moulding to 18 mm thick granite stone counters, Vanities, steps etc., including machine polishing to edge to give high gloss finish including making three nos of groove over tread etc. complete including cost, coveyance, loading and unloading and ,es of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by the Engineer in charge. FIRST FLOOR | BI01010001010000000000000515BI0100001164 | 138.1 | Mtr |
| 54 | 1.53 | Providing & Fixing tiles 600mm x 600mm special plain / printed series ceramic floor tiles having thickness 7mm to 8mm confirming to IS 13755 of approved make of Somany / Kajaria in floors treads or steps and landing on 20mm thick bed of cement mortar 1:4 (1cement : 4sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing. work complete in all respect as per specification and direction of Engineer-in-charge.(in toilet floor area) GROUND FLOOR | BI01010001010000000000000515BI0100001165 | 164.65 | Sqm |
| 55 | 1.54 | Providing & Fixing tiles 600mm x 600mm special plain / printed series ceramic floor tiles having thickness 7mm to 8mm confirming to IS 13755 of approved make of Somany / Kajaria in floors treads or steps and landing on 20mm thick bed of cement mortar 1:4 (1cement : 4sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing. work complete in all respect as per specification and direction of Engineer-in-charge.(in toilet floor area) FIRST FLOOR | BI01010001010000000000000515BI0100001166 | 77.39 | Sqm |
| 56 | 1.55 | Providing & Fixing tiles of 450mm x 450 mm / 600mm x 600mm / special plain/ printed series ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13755 of approved make of Somany / Kajaria / Johnson or equivalent in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and cleaning .work complete in all respect as per specification and direction of Engineer-in-charge. (in toilet walls) GROUND FLOOR | BI01010001010000000000000515BI0100001167 | 534.18 | Sqm |
| 57 | 1.56 | Providing & Fixing tiles of 450mm x 450 mm / 600 mmx 600mm / special plain/ printed series ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13755 of approved make of Somany / Kajaria / Johnson or equivalent in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and cleaning .work complete in all respect as per specification and direction of Engineer-in-charge. (in toilet walls) FIRST FLOOR | BI01010001010000000000000515BI0100001168 | 200.6 | Sqm |
| 58 | 1.57 | Providing and fixing in position wood plastic composite door frame with appropriate length of ETA Approved carbon steel galvanized (minimum 5 microns) double threaded 6.8 grade Polyamide PA 6 grade sleeve HRD C 10 anchor suitable for fastenings both on concrete & masonary/aerated blocks including cost of all materials, labours, T & P etc required for the work. complete in all respect as directed by the Architect/Engineer-in-charge GROUND FLOOR | BI01010001010000000000000515BI0100001169 | 207.02 | Mtr |
| 59 | 1.58 | Providing and fixing in position wood plastic composite door frame with appropriate length of ETA Approved carbon steel galvanized (minimum 5 microns) double threaded 6.8 grade Polyamide PA 6 grade sleeve HRD C 10 anchor suitable for fastenings both on concrete & masonary/aerated blocks including cost of all materials, labours, T & P etc required for the work. complete in all respect as directed by the Architect/Engineer-in-charge FIRST FLOOR | BI01010001010000000000000515BI0100001170 | 126.95 | Mtr |
| 60 | 1.59 | Providing and fixing of 35mm thick WPC Door Shutter(Solid) with teak edge leaping to the periphery of the shutter with pilishing as per detailed drawing with including, all hardwares & fixtures, SS tower bolt(150mm),Door stopper,SS aldrop(250mm),SS handle(200mm length),ss handle (150mm length) & SS Butt hinges -125mm x 65mm x2.12mm .including cost, conveyance, loading, T&P required for the work etc. complete in all respect as directed by the Engineer-in-charge GROUND FLOOR | BI01010001010000000000000515BI0100001171 | 78.24 | Sqm |
| 61 | 1.6 | Providing and fixing of 35mm thick WPC Door Shutter(Solid) with teak edge leaping to the periphery of the shutter with pilishing as per detailed drawing with including, all hardwares & fixtures, SS tower bolt(150mm),Door stopper,SS aldrop(250mm),SS handle(200mm length),ss handle (150mm length) & SS Butt hinges -125mm x 65mm x2.12mm .including cost, conveyance, loading, T&P required for the work etc. complete in all respect as directed by the Engineer-in-charge FIRST FLOOR | BI01010001010000000000000515BI0100001172 | 40.97 | Sqm |
| 62 | 1.61 | Supplying, fitting and fixing of M.S grills, grill gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railing ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing etc. complete in all respect as directed by the Engineer in charge ( W.I. / M.S. windows grills, grill gates, collapsible gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railings square bar along with required nos. of nails and screws and other required materials of approved quality and approved size shall be supplied by the contractor at his own cost.) GROUND FLOOR | BI01010001010000000000000515BI0100001173 | 3689.7 | Kg |
| 63 | 1.62 | Supplying, fitting and fixing of M.S grills, grill gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railing ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing etc. complete in all respect as directed by the Engineer in charge ( W.I. / M.S. windows grills, grill gates, collapsible gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railings square bar along with required nos. of nails and screws and other required materials of approved quality and approved size shall be supplied by the contractor at his own cost.) FIRST FLOOR | BI01010001010000000000000515BI0100001174 | 3284.1 | Kg |
| 64 | 1.63 | Finishing wall surface of walls with wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials, labour T&P etc. complete the work as per the direction of engineer incharge. GROUND FLOOR | BI01010001010000000000000515BI0100001175 | 2962.38 | Sqm |
| 65 | 1.64 | Finishing wall surface of walls with wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials, labour T&P etc. complete the work as per the direction of engineer incharge. FIRST FLOOR | BI01010001010000000000000515BI0100001176 | 1662.98 | Sqm |
| 66 | 1.65 | Providing & applying two or more coats of Best quality Acrylic Emulsion Paint of approved brand, shade and manufacture including on existing putty surface, one coat of cement primer, two coats of acrylic emulsion paint to give an even shade on walls and ceiling, including providing necessary scaffolding, cleaning the surface with water to remove all coating dust etc. including cost of all materials, labour, T&P, , taxes etc. complete as per specification. complete in all respect. GROUND FLOOR | BI01010001010000000000000515BI0100001177 | 2962.38 | Sqm |
| 67 | 1.66 | Providing & applying two or more coats of Best quality Acrylic Emulsion Paint of approved brand, shade and manufacture including on existing putty surface, one coat of cement primer, two coats of acrylic emulsion paint to give an even shade on walls and ceiling, including providing necessary scaffolding, cleaning the surface with water to remove all coating dust etc. including cost of all materials, labour, T&P, , taxes etc. complete as per specification. complete in all respect. FIRST FLOOR | BI01010001010000000000000515BI0100001178 | 1662.98 | Sqm |
| 68 | 1.67 | Painting to external building surface with weather coat two coats over a coat of primer of approved shade and quality of approved design after cleaning by watering & removing the dirts etc. to the surface to be painted including watering, curing, cost, conveyance of all materials, cost of all labour, brushes, T&P etc. and necessary scaffolding work complete as directed by the Engineer-in-charge. GROUND FLOOR | BI01010001010000000000000515BI0100001179 | 1348.42 | Sqm |
| 69 | 1.68 | Painting to external building surface with weather coat two coats over a coat of primer of approved shade and quality of approved design after cleaning by watering & removing the dirts etc. to the surface to be painted including watering, curing, cost, conveyance of all materials, cost of all labour, brushes, T&P etc. and necessary scaffolding work complete as directed by the Engineer-in-charge. FIRST FLOOR | BI01010001010000000000000515BI0100001180 | 733.79 | Sqm |
| 70 | 1.69 | Providing and painting two coats with synthetic enamel paint over a coat of primer to iron work of approved quality and approved shade confirmming to ISI on steel work to give an even shade in all floors at all height over a coat of primer of approved quality and shade including sand papering and making the surface smooth with cost, coveyance, loading and unloading, of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by Engineer-in-charge. GROUND FLOOR | BI01010001010000000000000515BI0100001181 | 121.13 | Sqm |
| 71 | 1.7 | Providing and painting two coats with synthetic enamel paint over a coat of primer to iron work of approved quality and approved shade confirmming to ISI on steel work to give an even shade in all floors at all height over a coat of primer of approved quality and shade including sand papering and making the surface smooth with cost, coveyance, loading and unloading, of all materials, cost of all labour, sundries, T&P, scaffolding etc. required for the work and complete in all respect as directed by Engineer-in-charge. FIRST FLOOR | BI01010001010000000000000515BI0100001182 | 109.47 | Sqm |
| 72 | 1.71 | Supplying , fitting and Fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr C/C and stainless steel square pipe bracing of size 32mm x 32mm x 2mm in three rows in staircase as per approved design and specification , buffing, polishing etc. with cost, conveyance, ,es of all materials, labour, T&P, etc. required for the complete in all respects. GROUND FLOOR | BI01010001010000000000000515BI0100001183 | 8.48 | Mtr |
| 73 | 1.72 | Supplying , fitting and Fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr C/C and stainless steel square pipe bracing of size 32mm x 32mm x 2mm in three rows in staircase as per approved design and specification , buffing, polishing etc. with cost, conveyance, ,es of all materials, labour, T&P, etc. required for the complete in all respects. FIRST FLOOR | BI01010001010000000000000515BI0100001184 | 8.48 | Mtr |
| 74 | 1.73 | Waterproofing to the roof slab (a) Surface preparation : \nCleaning the surface thoroughly by chipping the roof slabs using breakers, wire brush, mechanical grinder for making it free from all loose particles, dust etc. then total cleaning through air blower followed by water jetting and allowing the surface to dry. (b) Application :Supply and application of Nano Technology OrganoSilane based Zycosil + @ 1:20 (one part Zycosil + and 20 parts of clean water) to the saturation level on the entire flat surface and upto 300mm (1ft.) to the parapet walls and then allowing for drying 24 hrs., test the surface for hydrophobicity. Then application of 100% acrylic co-polymer Zycoprime+, cement and fine sand (100 mesh) mixed at a consistency of paste form and filling drainage pipes gaps. Then application of one coat of Zycoat mix of Zycoprime + and grey cement @ 1:1.5 ratio ( 1 part Zycoprime + and 1.5 part cement). 2ndcpat of Zycoat mix to be applied after the drying of first coat in the same procedure followed by sprinkling of sieved sand on the top of the slurry. Then allow it to dry followed by proper curing with water for at least two days.(c) Coving :Coving has to be done with Zycomix (a mortar prepared with Zycoprime+, cement and sand in the ratio of 1:5:15 and water as per workability to obtain a uniform paste). Finally cure with water to the entire treated roof and parapet wall for three days. | BI01010001010000000000000515BI0100001185 | 204.54 | Sqm |
| 75 | 1.74 | Water proofing to the sunken slab (a) Surface preparation : Cleaning the surface thoroughly by wire brush, mechanical grinder for making it free from all loose particles, dust etc. then total cleaning through air blower followed by water jetting and then allowing the surface to dry.(b) Application before PCC :Supply and application of Nano Technology OrganoSilane based Zycosil+@ 1:20 (one part Zycosil+ and 20 parts of clean water) to the saturation level on the entire flat surface and upto to the height of the sunken slab casted and then allowing for drying 24 hrs., test the surface for hydrophobicity. (c) Coving :Coving has to be carried on with Zycomix (a mortar prepared with Zycoprime+, cement and sand in the ratio of 1:5:15 and water as per workability to obtain a uniform paste). This should be followed by application of Zycoat on the corner surface of the sunken slabs. The above Zycomix must be applied in the gaps of pipe joints in the sunken slabs followed by application of Zycoat.(Note : The above application “ b & c” should be done before PCC) (d) Application after PCC:Supply and application of Nano Technology OrganoSilane based Zycosil+@ 1:20 (one part Zycosil+ and 20 parts of clean water) to the saturation level on the entire flat PCC surface and upto to 1 mtr height of the wall. This should be done on a sound PCC surface with sufficient curing and drying. Then application of one coat of Zycoat (1 part Zycoprime+ mixed with 1.5 part cement) on Zycosil+ treated surface followed by one coat of Elastocoat (mixing of 100% acrylic co-polymer high strength elongation of 200 - 250% Elastobar 1 part and grey cement 1 part) with the help of brush. Then allow it to dry followed by proper curing with water for at least 3 days.\n \n\n | BI01010001010000000000000515BI0100001186 | 74.67 | Sqm |
| 76 | 1.75 | Providing & filling sunken slab with 40mm size brick bat with overburnt kiln burnt bricks including filling, compacting, watering , levelling the same as per the direction of Engg-in-Charge with all material,labour, scafolding, tools, plant etc for complete. | BI01010001010000000000000515BI0100001187 | 34.12 | Cum |
| 77 | 1.76 | Providing 25mm thick grading concrete in C.C. (1:2:2) laid in proper slope over terrace roof slab by using two part of sand, one part of cement and two parts of 6mm size black hard crusher broken granite chips with addition of water proofing compound of approved quality to be mixed with specified ratio including watering, curing, cost, conveyance, royalties, ,es of all materials, cost of all labour, T&P etc. complete as required for the finished item of work as directed by the Engineer-in-charge. FIRST FLOOR | BI01010001010000000000000515BI0100001188 | 178.89 | Sqm |
| 78 | 1.77 | Providing 20mm thick plaster in C.M. (1:4) as grading plaster after removing the false if necessary and close deep chipping including rounding of the corners, recess and roughening concrete surface where necessary, watering and curing, finished smooth over R.C.C. surface, including cost, conveyance, royalty, ,es of all materials, cost of all labour, T&P etc. complete as per direction of the Engineer-in-charge. | BI01010001010000000000000515BI0100001189 | 25.65 | Sqm |
| 79 | 1.78 | Supplying, Diluting & Spreading Chemical Emulsion like CHLORPYRIPHOS OR Other Chemical approved by the Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer as preconstructional antitermite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313/1981(Part-II) complete including cost, conveyance, loading, unloading and ,es of all materials, cost of all labour, T&P, sundries and scaffolding where required for the work etc. as directed by the Engineer -in -charge.( The payment shall be made on the basis of the actual measurement of the plinth area of the building at Ground Floor and vertical faces will not be measured for payment) | BI01010001010000000000000515BI0100001190 | 923.2 | Sqm |
| 80 | 1.79 | Providing and fixing of factory made UPVC 2-track Sliding / 3 track window complete, comprising UPVC multi-chambered frame of size 67mm x 54mm with wall thickness of 2.3mm (+-0.2 mm ) having in-built UPVC roller track on top and uPVC sash of size 64mm x 47mm with wall thickness of 2.3mm (+-0.2 mm ) duly reinforced with G.I. section 1.2 mm (+/- 0.2mm), wherever required. All corners of frame and sash will be fusion welded. After placing 5 mm Clear Annealed glass in the sash, UPVC glazing bead, interlock, EPDM gasket, brush will be provided including hardware, i.e., touch lock and rollers & proper drainage system shall be provided. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Architect or Engineer-In-Charge. GROUND FLOOR(Torfenster/Lingel/Encraft/Koemmerling/Wintech/Builtfy) | BI01010001010000000000000515BI0100001191 | 109.55 | Sqm |
| 81 | 1.8 | Providing and fixing of factory made UPVC 2-track Sliding / 3 track window complete, comprising UPVC multi-chambered frame of size 67mm x 54mm with wall thickness of 2.3mm (+-0.2 mm ) having in-built UPVC roller track on top and uPVC sash of size 64mm x 47mm with wall thickness of 2.3mm (+-0.2 mm ) duly reinforced with G.I. section 1.2 mm (+/- 0.2mm), wherever required. All corners of frame and sash will be fusion welded. After placing 5 mm Clear Annealed glass in the sash, UPVC glazing bead, interlock, EPDM gasket, brush will be provided including hardware, i.e., touch lock and rollers & proper drainage system shall be provided. Window will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Architect or Engineer-In-Charge. FIRST FLOOR (Torfenster/Lingel/Encraft/Koemmerling/Wintech/Builtfy) | BI01010001010000000000000515BI0100001192 | 104.92 | Sqm |
| 82 | 1.81 | Supplying & Fixing of Mild steel tubular Pipe made out of ERW tubes, grade YST 210 conforming to ISS NO. 1161/79 ( 3rd revision) duly painted with red oxide primer as per the architectural requirement for application . positioning with necessary accessories with scaffolding complete in all respects as per direction of Engineer-in-charge. . | BI01010001010000000000000515BI0100001193 | 335.76 | Kg |
| 83 | 1.82 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdor floors such as footpath, courtyard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge | BI01010001010000000000000515BI0100001194 | 15.64 | Sqm |
| 84 | 1.83 | Providing neat cement punning over plastered/ concrete surface including watering and curing complete with cost, coveyance, loading and unloading, royalties of all materials and cost of all labour, T&P and scaffolding required for the work etc. as directed by the Engineer in charge. | BI01010001010000000000000515BI0100001195 | 249.94 | Sqm |
| 85 | 1.84 | Dismantling of brick or stone masonry in lime/ cement mortar in any proportion above 3m. height including stacking the useful materials for reuse and removing the debris within 50m. Lead etc. complete as per direction of EIC / Architect. (Ground Floor) | BI01010001010000000000000515BI0100001196 | 23.91 | Cum |
| 86 | 1.85 | Supplying all labour for dismantling doors and windows including stacking of useful material for reuse and removal of debris within 50m initial lead including cost onveyance,royalties & ,es of all labour with T & P required etc complete as per direction of Architect / Engineer-in-charge. (Ground floor) | BI01010001010000000000000515BI0100001197 | 19.22 | Sqm |
| 87 | 1.86 | Disposal of debris ( dismantled items obtained from RCC, Brick work, Plaster, Tarfelts, Grading/Terracing etc. ) from theworking site to the out side of campus/ inside the campus as per the direction of Engineer in Chrage/ Authority including loading, unloading, spreading, levelling by manually/ mechanical means including cost of all labour, tools plant to complete the work in all respects as per direction of Architect / Engineer-in-charge. ( Upto distance of 5 Km) | BI01010001010000000000000515BI0100001198 | 21.54 | Cum |
| 88 | 1.87 | Providing and fixing gypboard suspended false ceiling (single layers) in different levels, recesses, flat areas as per design with G.I. Framework using Gypsteel of perimeter channels, intermediate channels and ceiling sections) and 12.5 mm taped edge gypboard screw fixed to ceiling section as per design , complete with fixing and finishing of tapered and square edges of board with jointing compound paper tape and 2 coats suitable primer including all cost of materials , labour, overheads T & P etc., complete.and painting the entire ceiling area with plastic emulsion paint ( 2 & more coats ) to get an even shade as per the detail design and specification. measurement will be taken flat area of the ceiling for payment.no additional payment made for the different level/ drop. | BI01010001010000000000000515BI0100001199 | 316.54 | Sqm |
| 89 | 1.88 | Providing and Fixing of Armstrong/Gyprex / Eqv suspended ceiling system with Fine fissured microlook tiles in modules size of 600 x 600 x 15mm laid on armstrong silhouette reveal profile grid system with 15mm white flange incorporating a 3 mm or 6mm central recesss.Silhouette mail runner & cross tee ti have mitred ends and birdsmuth notches to provide mitered cruciform junction. | BI01010001010000000000000515BI0100001200 | 211.03 | Sqm |
| 90 | 1.89 | Providing & Fixing Pelmet made of 19mm BWR Grade Block Board (IS-1659) with teak wood beading (polished) to the exposed edges & exposed surface laminated with 1mm thick laminate & inside surface painted with 2 coats of enamel paint over 1 coat of primer cost includes cost of all material, labour, T&P etc. complete in all respects (excluding GST) as per specification and as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001201 | 376.04 | Mtr |
| 91 | 1.9 | Providing & fixing of false ceiling using fiber cement plank of SHERA make manufactured by wet recessed autoclaved technology pre-colored plank (afronesia brown/wall nut/cherry red/golden sand teak) teak texture (External Grade) thickness of 8mm. SHERA Fiber cement plank should be of minimum density 1300kg/ m3 (±50) and comply to ASTM C 1185 and ISO 8336 part (E) for confirming durability properties and BS 476 – part 5, 6 & 7, Thermal conductivity should be minimum 0.15 W/m°K and PH value should be in the range of 7 – 8. Depending on height of structure SHERA planks to be fixed using Aluminum frame section of 50mm x 25mm of suitable gauge (within1mm thick) with minimum spacing 450mm to 600mm or as per direction of Engineer In charge. SHERA pre-colored teak planks to be fixed using SHERA Screws of Tensile strength 34N and Shear strength 68N on framing. Screw heads are covered with acrylic putty of the next plank giving uniform natural groove/overlap (as per engineer drawing). All plank to plank joints to be staggered including all cost of materials , labour, overheads T & P etc. complete in all respect as per the direction of architect incharge. | BI01010001010000000000000515BI0100001202 | 387.02 | Sqm |
| 92 | 1.91 | Providing and fixing the Reflective Insulation material made up of high resistance anti corrosive both side aluminium foil with 20mm closed cell non-toxic fiber free bubbles manufactured by Divine Thermal wrap Pvt.Ltd. Consist low Emissivivity 3%(ASTM 1371),Reflectivity 97% (ASTM 408,Fire Retardant (BS 476 Part 6,Part 7), Aluminium foil thickness-12 microns ,Roll size ( 1.25m x 15 m ). including cost of all material labour,T & P, and cost of all hardware . Work complet as per the direction of Architect /Engineer incharge. | BI01010001010000000000000515BI0100001203 | 656.86 | Sqm |
| 93 | 1.92 | Providing & fixing wall & column panelling by fixing 19mm BWR grade ply confirming to IS-1659(2004) fixed with wall by secondary hard wood (50x50mm) forming a grid of 600x600mm & screws. Then fixing laminate 1.00mm thick of approved make & shade as per detailed working drawing including cost of labour & cost of materials, T&P etc. complete in all respects (excluding GST) as per the specification and as per direction engineer in charge. | BI01010001010000000000000515BI0100001204 | 466.33 | Sqm |
| 94 | 1.93 | Providing, fitting and fixing of chick blinds with black out synthetic fabric fix to bottom aluminum C profile the profile including end cap. The top aluminum profile will have both side PVC control unit including will have rope to operate down and upward direction of the blinds. the shade of fabric will as per the approval of the architect the price will be including all cost of the labour and material | BI01010001010000000000000515BI0100001205 | 40.94 | Sqm |
| 95 | 1.94 | Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficeint) of 0.50 (minimum) as per IS 8225:1987, Ligth reflectance as per BS:476 (part 6&7), Humidity resistance of 100%, thermal conductivity<0.043 W/m as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel 0.50mm thick pressed section (glavanizing @120 grams per sqm including both sides) i.e. vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50x32m fixed to the floor and soffit at 600mm centersa using 12mm dia, 50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horizontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre ) roll and two coats of primer suitable for panelling as per manufacturer's specification as per direction of Engineer-in-Charge all complete. With 15mm thick fully perforated square/butt edge light weight calcium silicate panels/tiles | BI01010001010000000000000515BI0100001206 | 345.59 | Sqm |
| 96 | 1.95 | Supply of cow dung manure, well decomposed, garbage free including transportation & delivery at nursery per tractor load etc., all completed as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001207 | 15 | Cum |
| 97 | 1.96 | Lifting & spreading of manure uniformly over the surface area as per landscape design/advice of the site in-charge & all complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001208 | 15 | Cum |
| 98 | 1.97 | Supply of broad leaf grass turf, disease free, glossy green etc. well grown, carpet formed 2' thickness about for an area of 15613 sqmtr. Including transportation & delivery at site as per instruction of in-charge at site at 1:5 ratio for dibbling etc.complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001209 | 100 | Sqm |
| 99 | 1.98 | Dibbling of grass in required spacing including rolling, 1st watering & maintenace of the lawn to make it free from weeds top dressing with fertilizer and pesticide and mixture of grass planting as per instruction of Officer in-charge at site etc. complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001210 | 100 | Sqm |
| 100 | 1.99 | Supply of Hibiscus Rosachinensis 3' ht. well grown, health & disease free including trasportation and delivery site etc. complete as per direction of EIC/Architect. . | BI01010001010000000000000515BI0100001211 | 25 | Each |
| 101 | 2 | Supply of Nereium Oleander 3½' ht. well grown, healthy & disease free including transportation and delivery to the site etc. complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001212 | 25 | Each |
| 102 | 2.01 | Supply of Ixora Coccena 2½' ht. well grown, healthy & disease free including transportation and delivery site etc. complete as per direction of EIC/Architect. . | BI01010001010000000000000515BI0100001213 | 25 | Each |
| 103 | 2.02 | Supply of Tecoma stans 2½' well grown, healthy & disease free including transportation and delivery to the site etc. complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001214 | 25 | Each |
| 104 | 2.03 | Supply of Almonda Cathertica 3'ht. well grown, decorative stage, healthy & disease free including transportation and delivery to site etc. complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001215 | 25 | Each |
| 105 | 2.04 | Supply of Poinsetia 3'ht. well grown, decorative stage, healthy & disease free including transportation and delivery to site etc. complete as per direction of EIC/Architect. . | BI01010001010000000000000515BI0100001216 | 25 | Each |
| 106 | 2.05 | Supply of Tarat dwarf 2'ht. well grown, decoraive stage, healthy & disease free including transportation and delivery to site etc. complete as per direction of EIC/Architect. . | BI01010001010000000000000515BI0100001217 | 25 | Each |
| 107 | 2.06 | Supply of Hena 3'ht. well grown, decorative stage, healthy & disease free including transportation and delivery to site etc. complete as per direction of EIC/Architect. . | BI01010001010000000000000515BI0100001218 | 25 | Each |
| 108 | 2.07 | Supply of Varigated Tagar 2'ht. well grown, decorative stage, healthy & disease free including transportation and delivery to site etc. complete as per direction of EIC/Architect. . | BI01010001010000000000000515BI0100001219 | 25 | Each |
| 109 | 2.08 | Supply of Song of India 2½'ht. well grown, decorative stage, healthy & disease free including transportation and delivery to the site etc. complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001220 | 25 | Each |
| 110 | 2.09 | Supply of Gardenia Grandiflora 2½'ht. well grown, decorative stage, healthy & disease free including transportation and delivery to the site etc. complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001221 | 10 | Each |
| 111 | 2.1 | Supply of Musanda Red 2½'ht well grown, decorative stage, healthy & disease free including transportation and delivery to the site etc. complete as per direction of EIC/Architect. . | BI01010001010000000000000515BI0100001222 | 10 | Each |
| 112 | 2.11 | Supply of Fox Tail Palm 7'ht. well grown, decorative stage, healthy & disease free including transportation and delivery to the site etc. complete as per direction of EIC/Architect. . | BI01010001010000000000000515BI0100001223 | 10 | Each |
| 113 | 2.12 | Supply of Furcaria Watsonia 2'ht. well grown, decorative stage, healthy & disease free including transportation and delivery to the site etc. complete as per direction of EIC/Architect. . | BI01010001010000000000000515BI0100001224 | 10 | Each |
| 114 | 2.13 | Supply of Juniper species 2'ht. well grown, decorative stage, healthy & disease free including transporation and delivery to the site etc. complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001225 | 10 | Each |
| 115 | 2.14 | Supply of Ficus Blackee 4'ht. well grown, decorative stage, healthy & disease free including transportation and delivery to the site etc. complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001226 | 10 | Each |
| 116 | 2.15 | Digging of pits size (2'x2'x2') application of fertilizer, pesticide, manuare, planting, staking, after care with 20% mortality replacement etc. complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001227 | 10 | Each |
| 117 | 2.16 | Supply of potted Rose hybrid Bueded (12\") plants well grown, decorative stage, healthy disease free & in flowering stage including transportation and delivery to the site etc. complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001228 | 10 | Each |
| 118 | 2.17 | Supply of hedge plants i.e. Duranta Goldiana (ploy) 6\"ht., well grown, bushy, disease free for plantation including transportation & delivery at nursery etc. complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001229 | 10 | Each |
| 119 | 2.18 | Colium potted plants in 10\" size pot, well grown, decorative stage, healthy & disease free including transportation and delivery to the site etc. complete as per direction of EIC/Architect. . | BI01010001010000000000000515BI0100001230 | 10 | Each |
| 120 | 2.19 | Thuja 3'ht. Potted plants, well grown, decorative stage, healthy & disease free including transportation and delivery site etc. complete as per direction of EIC/Architect. . | BI01010001010000000000000515BI0100001231 | 10 | Each |
| 121 | 2.2 | Red Dracena potted plants in 10\" size pot, well grown, decorative stage, healthy & disease free including transportation and delivery to the site etc. complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001232 | 10 | Each |
| 122 | 2.21 | Bougainvillea potted plants in 10\" size pot, well grown, decorative stage, healthy & disease free including transportation and delivery to the site etc. complete as per direction of EIC/Architect. . | BI01010001010000000000000515BI0100001233 | 10 | Each |
| 123 | 2.22 | Dracena (Yellow Colour) potted plants in 10\" size pot, well grown, decorative stage, healthy & disease free including transportation and delivery to the site etc. complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001234 | 10 | Each |
| 124 | 2.23 | Bougainvillea (Poly pack) plants in 10\" size pot, well grown, decorative stage, healthy & disease free including transportation and delivery to the site etc. complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001235 | 10 | Each |
| 125 | 2.24 | Cleaning & grubbing road land including uprooting rank vegetation, grass, bushes, shurbes,sapling and trees girth upto 300mm ,removal of stumps of trees cut earier and disposal of unsevicable materials and stacking of servicable materials to be used or auctioned up to lead of 1000 meters including removal and disposal of top organic soil not exceeding 150mm thickness etc. complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001236 | 6457.4 | Sqm |
| 126 | 2.25 | Earth work in hard soil or gravelly soil in embankment, roads etc. within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per specification approved by the Department alongwith proper compaction with P.R.R. including hire and running charges of P.R.R. (section measurement to be taken on the finished compacted section of the fill) | BI01010001010000000000000515BI0100001237 | 1073.64 | Cum |
| 127 | 2.26 | Compacting and watering upto OMC rolling earth work with PRR in embankment in layer not exceeding 0.23m by PRR including hire charges of PRR including all cost of labour and materials, T&P etc. complete as per direction of EIC. | BI01010001010000000000000515BI0100001238 | 1073.64 | Cum |
| 128 | 2.27 | Providing Moorum and sand admixture filling in sub-base and compacting including cost of all materials labour T&P etc.complete as per direction of EIC. | BI01010001010000000000000515BI0100001239 | 536.82 | Cum |
| 129 | 2.28 | Flank dressing to proper camber including cost of all materials labour T&P etc.complete. As per dirction of EIC | BI01010001010000000000000515BI0100001240 | 3578.8 | Sqm |
| 130 | 2.29 | Rolling and compacting sub grade by loosning earth 15cm depth including cost of all materials labour T&P etc.complete as per direction of EIC. | BI01010001010000000000000515BI0100001241 | 4746.16 | Cum |
| 131 | 2.3 | Providing, laying, spreading and compacting graded stone aggregate (Gr-II) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 404 of MoRT&H specifications for Road & Bridgeworks (5th Revision) and as per direction of EIC. | BI01010001010000000000000515BI0100001242 | 357.88 | Cum |
| 132 | 2.31 | Providing, laying, spreading and compacting graded stone aggregate (Gr-III) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 404 of MoRT&H specifications for Road & Bridgeworks (5th Revision) and as per direction of EIC. | BI01010001010000000000000515BI0100001243 | 357.88 | Cum |
| 133 | 2.32 | Supply and fixing of geotextile membrane layer at just 300mm below the paving tile layer to provide protection to sand not to enter into the lower layer as per the direction of the EIC. | BI01010001010000000000000515BI0100001244 | 3578.8 | Sqm |
| 134 | 2.33 | Supplying and laying of factory made hydraulically pressed and mechanically compacted free cast interlocking UNI PAVER blocks of Samudyam make / equivalent of 40MM - 80mm thick of approved quality, colour and size in all floors at all height on 25mm thick bed of cement mortar of mix (1:1) laid in proper slope and gradient with screened and washed sharp sand for mortar and with Portland Slag Cement (PSC) grouted with neat white cement slurry with required quantities of pigments of approved marks watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work complete in all respect as directed by the Engineer-in-charge | BI01010001010000000000000515BI0100001245 | 3578.8 | Sqm |
| 135 | 2.34 | Supplying and laying of Grass Pavers of M-30 grade MGP-1 (X-type) 60mm thick interlocking type including preparation of sub base with 100mm sand and leveling,laying of interlocking paver block with sand binding and final compaction with plate vibrator finishing the surface including cutting of blocks at the edges with all labour and materials etc complete as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001246 | 3578.8 | Sqm |
| 136 | 2.35 | Grassing with Providing and laying Grassing with carpet grass(zoysia japonica) including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing including supplying good earth if needed. In rows 5 cm. apart in either direction. | BI01010001010000000000000515BI0100001247 | 725 | Sqm |
| 137 | 2.36 | Providing and applying primer coat with bitumen emulsion on prepared surface of granular base including clearing of road surface and spraying primer at the rate of 0.60 kg/sqm using mechanical means as per Clause 502 of MoRT&H Specifications for Road & Bridge works | BI01010001010000000000000515BI0100001248 | 2878.6 | Sqm |
| 138 | 2.37 | Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous / granular surface cleaned with mechanical broom as per Clause 503 of MoRT&H Specifications for Road & Bridge works | BI01010001010000000000000515BI0100001249 | 2878.6 | Sqm |
| 139 | 2.38 | Providing and laying semi dense bituminous concrete with batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder of 60/70 penetration grade of bitumen, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the requried grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per Clause 508 of MoRT&H Specifications for Road & Bridge works (4th Revision) including hire and running charges of PRR etc complete. including cost of all materials labour T&P etc.complete. \nGrading-I (13mm nominal size) | BI01010001010000000000000515BI0100001250 | 71.97 | Cum |
| 140 | 2.39 | Supply of good quality garden soil preferably red alluvial/sandy loam with texture neither too coarse nor too fine with a fair degree of water retaining adequate humus with a ph range from 6.5 to 7.5 should be free from any undesirable inorganic materials like wastage constructioin, roots and bushes of wild plants, polythene garbage etc., to be collected after duly screened including cost, conveyance, royalty, taxes and other charges with labour and T&P charges for loading, unloading and stacking at site in separate heaps of (1.5 x 1.5 x 0.5) cum or its multiplies taken into 1(one) cum for measurement and payment purposes and to be uniformly spreaded over an area of 6000 sq.mtr with average thickness of 6 cm and completed in all respects. | BI01010001010000000000000515BI0100001251 | 2971.5 | Cum |
| 141 | 2.4 | Supply& Lifting & spreading of manure uniformly over the surface area as per landscape design/advice of the site in-charge & all completed as per direction of EIC. | BI01010001010000000000000515BI0100001252 | 2971.5 | Cum |
| 142 | 2.41 | Supply of cow dung manure, well decomposed, garbage free including transportation & delivery at nursery per tractor load etc., all completed as per direction of EIC. | BI01010001010000000000000515BI0100001253 | 1485.75 | Cum |
| 143 | 2.42 | Lifting & spreading of good garden soil uniformly over the surface area as per landscape design/advice of the site in-charge & all completed. | BI01010001010000000000000515BI0100001254 | 1485.75 | Cum |
| 144 | 2.43 | Supply of broad leaf grass turf, disease free, glossy green etc. well grown, carpet formed 2' thickness about for an area of 15613 sqmtr. Including transportation & delivery at site as per instruction of in-charge at site at 1:5 ratio for dibbling etc., complete all respect. | BI01010001010000000000000515BI0100001255 | 9754.5 | Sqm |
| 145 | 2.44 | Dibbling of grass in required spacing including rolling, 1st watering & maintenace of the lawn to make it free from weeds top dressing with fertilizer and pesticide and mixture of grass planting as per instruction of Officer in-charge at site & complete in all respect | BI01010001010000000000000515BI0100001256 | 9754.5 | Sqm |
| 146 | 2.45 | Fixing European water closet with cistern, Draingage L bend pipe, Gsket and installation kit with PP normar close seat cover, hinges, Fixing accessories and Acdessories seet, size: 375x620x770mm (European type W.C pan) with integral 'S' or 'P' trap conforming to IS 2556 : Part 8-2004, to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification.JAQUAR MAKE CAT- CNS-WHT-353SPPZ | BI01010001010000000000000515BI0100001257 | 21 | Each |
| 147 | 2.46 | Fixing Basin of size 515x415x195 mm with full pedestal (ECS-WHT-301) conforming to IS 2556 : Part 4-2004 with cast Iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification. (JAQUAR ESSCO MAKE, CAT-ECS-WHT-805) | BI01010001010000000000000515BI0100001258 | 19 | Each |
| 148 | 2.47 | Fixing Table top Basin of size 425x340x175 mm (CNS-WHT-903) and pillar cock (CON-011KN) conforming to IS 2556 : Part 4-2004 with cast Iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification. | BI01010001010000000000000515BI0100001259 | 11 | Each |
| 149 | 2.48 | Providing, Supplying & Fixing of Single Towel Rail, Stainless Steel of Jaquar (Cat No.- ACN- CHR-1111SM) Size- 600 mm long with all fittings & fixtures complete including making good the damages . including cost of all materials, labour, T&P, lead, royality etc.complete in all respects as per direction of Architect /Engineer in charge. | BI01010001010000000000000515BI0100001260 | 27 | Each |
| 150 | 2.49 | Providing, Supplying & Fixing of Towel Ring Square of Jaquar (Cat No. - ACN- CHR-1121N) with all fittings & fixtures complete including making good the damages . including cost of all materials, labour, T&P, lead, royality etc.complete in all respects as per direction of Architect /Engineer in charge. | BI01010001010000000000000515BI0100001261 | 30 | Each |
| 151 | 2.5 | Providing, Supplying & Fixing of SOAP DISH of Jaquar (Cat No. - ACN-CHR-1131N) with all fittings & fixtures complete including making good the damages . including cost of all materials, labour, T&P, lead, royality etc.complete in all respects as per direction of Architect /Engineer in charge. | BI01010001010000000000000515BI0100001262 | 57 | Each |
| 152 | 2.51 | Providing, Supplying & Fixing of Hand Shower (Health Faucet) with 8mm dia, 1.2m long flexible tube and wall hook of Jaquar (Cat No.- ALD-CHR-573)with all fittings & fixtures complete including making good the damages . including cost of all materials, labour, T&P, lead, royality etc.complete in all respects as per direction of Architect /Engineer in charge. | BI01010001010000000000000515BI0100001263 | 21 | Each |
| 153 | 2.52 | Providing, Supplying & Fixing of 2 way Bib cock with wall flange of Jaquar (15mm dia cp two way bib cock(Jaquar )CON-CHR-041KN) with all fittings & fixtures complete including making good the damages . including cost of all materials, labour, T&P, lead, royality etc.complete in all respects as per direction of Architect /Engineer in charge. | BI01010001010000000000000515BI0100001264 | 26 | Each |
| 154 | 2.53 | Fixing of Bib cock (with straight line model) with wall flange polished bright conforming to IS:781-1995 of the following nominal sizes as per specification complete. (15 mm dia CP Bib cock (Jaquar)CON-CHR-037KN.) | BI01010001010000000000000515BI0100001265 | 17 | Each |
| 155 | 2.54 | Fixing Wall mixer non-telephonic shower arrangement with connecting legs & wall flanges with 450mm long Braided Hoses with long screws, shanks and back nuts of the following nomional bore as per specification. (JAQUAR MAKE, CAT-CON-219KN) | BI01010001010000000000000515BI0100001266 | 6 | Each |
| 156 | 2.55 | Fixing of Angular Stop Cocks with flange conforming to IS:781-1995 of the following nominal sizes as per specification complete. (JAQUAR ESSCO MAKE, CAT-SQT-526KN) | BI01010001010000000000000515BI0100001267 | 72 | Each |
| 157 | 2.56 | Fixing of Concealed Stop Cocks with flange conforming to IS:781-1995 of the following nominal sizes as per specification complete. (JAQUAR ESSCO MAKE, CAT-SQT-514AKN) | BI01010001010000000000000515BI0100001268 | 25 | Each |
| 158 | 2.57 | Providing, Supplying & Fixing of Shower Arm 20mm Dia & 450mm Long Round Shape with 90º Bend for wall Mounted Showers with Flange with Maze Overhead Shower 240mm Round Shape single flow (Body & Face Plate Stainless Steel with chrome finish) with rubit cleaning system of Jaquar (Cat No.- SHA-CHR-479L450 and OHS-CHR-1623)with all fittings & fixtures complete including making good the damages . including cost of all materials, labour, T&P, lead, royality etc.complete in all respects as per direction of Architect /Engineer in charge. | BI01010001010000000000000515BI0100001269 | 6 | Each |
| 159 | 2.58 | Fixing Glass shelf of 550 mm long complete with Chromiun Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws, complete as per spwcification. (JAQUAR MAKE, CAT-AQN-7771) | BI01010001010000000000000515BI0100001270 | 6 | Each |
| 160 | 2.59 | Providing, Supplying & Fixing of Double hook of Jaquar (Cat No.- ANC-CHR-1161N)with all fittings & fixtures complete including making good the damages . including cost of all materials, labour, T&P, lead, royality etc.complete in all respects as per direction of Architect /Engineer in charge. | BI01010001010000000000000515BI0100001271 | 10 | Each |
| 161 | 2.6 | Providing, Supplying & Fixing of all materials, labour, T&P and fixing mirror of 600 x 450mm size (Atul/ Twin bird/Charlie/ eqv )glass mounted on 4mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer in charge.as per PHD S/R Rate | BI01010001010000000000000515BI0100001272 | 30 | Each |
| 162 | 2.61 | Providing & Fixing of PVC grating with 125mm stainless steel grating with/ without hole for waste pipe in floors / at any location cost includes all materials, labour, tools,plant etc. complete in all respects.as per price list of ASTRAL | BI01010001010000000000000515BI0100001273 | 52 | Each |
| 163 | 2.62 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes (type-A / ring fit type ) with all PVC fittings of ASTRAL/AJAY/SUPREME make as per IS 13592 to walls with nails, bobbins and laying in trenches including all pipe fittings, jointing materials, tools plant, labour & all material, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge.160mm dia PVC (SWR) pipe class \"A\" ( with wall thickness of 3.2mm to 3.8mm) | BI01010001010000000000000515BI0100001274 | 200 | Mtr |
| 164 | 2.63 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes (type-A / ring fit type ) with all PVC fittings of ASTRAL/AJAY/SUPREME make as per IS 13592 to walls with nails, bobbins and laying in trenches including all pipe fittings, jointing materials, tools plant, labour & all material, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge.110 mm dia PVC (SWR) pipe Class ‘A’ (with wall thick of 2.20 mm to 2.70 mm) | BI01010001010000000000000515BI0100001275 | 120 | Mtr |
| 165 | 2.64 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes (type-A / ring fit type ) with all PVC fittings of ASTRAL/AJAY/SUPREME make as per IS 13592 to walls with nails, bobbins and laying in trenches including all pipe fittings, jointing materials, tools plant, labour & all material, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. 75 mm dia PVC (SWR) pipe Class ‘A’ (with wall thick of 1.8 mm to 2.20 mm ) | BI01010001010000000000000515BI0100001276 | 155 | Mtr |
| 166 | 2.65 | Supplying all materials, labour, T&P for fitting and fixing and laying 110mm dia UPVC Union of appd. make including supply of all jointing materials like Gaskets, adhesive, solvent, cement etc and fixing to walls with supply of wooden plugs and nails, bobbins, clamps including scaffolding and testing etc as per PH specification and direction of the Engineer in charges (Make :- Oriplast / Supreme) | BI01010001010000000000000515BI0100001277 | 30 | Each |
| 167 | 2.66 | Supplying all materials, labour, T&P for fitting and fixing and laying 110mm dia UPVC 110mm x 75mm reducer socket of appd. make including supply of all jointing materials like Gaskets, adhesive, solvent, cement etc and fixing to walls with supply of wooden plugs and nails, bobbins, clamps including scaffolding and testing etc as per PH specification and direction of the Engineer in charges (Make :- Oriplast / Supreme) | BI01010001010000000000000515BI0100001278 | 30 | Each |
| 168 | 2.67 | Supplying all materials, labour, T&P for fitting and fixing ferrule confirming to IS:2692-1978 OF 25mm dia of appd. make including supply of all jointing materials like Gaskets, adhesive, solvent, cement etc and fixing to walls with supply of wooden plugs and nails, bobbins, clamps including scaffolding and testing etc as per PH specification and direction of the Engineer in charges (Make :- Jaquar) | BI01010001010000000000000515BI0100001279 | 20 | Each |
| 169 | 2.68 | Supplying all materials, labour, T&P for fitting and fixing and laying 100mm dia PVC double junction plain Cross- T of appd. make including supply of all jointing materials like Gaskets, adhesive, solvent, cement etc and fixing to walls with supply of wooden plugs and nails, bobbins, clamps including scaffolding and testing etc as per PH specification and direction of the Engineer in charges (Make :- Oriplast / Supreme) | BI01010001010000000000000515BI0100001280 | 3 | Each |
| 170 | 2.69 | Supplying all materials, labour, T&P for fitting and fixing and laying 100mm dia PVC single junction plain- T of appd. make including supply of all jointing materials like Gaskets, adhesive, solvent, cement etc and fixing to walls with supply of wooden plugs and nails, bobbins, clamps including scaffolding and testing etc as per PH specification and direction of the Engineer in charges (Make :- Oriplast / Supreme) | BI01010001010000000000000515BI0100001281 | 2 | Each |
| 171 | 2.7 | Supplying all materials, labour, T&P for fitting and fixing and laying 100mm dia PVC single junction plain- Y of appd. make including supply of all jointing materials like Gaskets, adhesive, solvent, cement etc and fixing to walls with supply of wooden plugs and nails, bobbins, clamps including scaffolding and testing etc as per PH specification and direction of the Engineer in charges (Make :- Oriplast / Supreme) | BI01010001010000000000000515BI0100001282 | 2 | Each |
| 172 | 2.71 | Supplying all materials, labour, T&P for fitting and fixing and laying 100mm dia PVC single junction with door of appd. make including supply of all jointing materials like Gaskets, adhesive, solvent, cement etc and fixing to walls with supply of wooden plugs and nails, bobbins, clamps including scaffolding and testing etc as per PH specification and direction of the Engineer in charges (Make :- Oriplast / Supreme) | BI01010001010000000000000515BI0100001283 | 2 | Each |
| 173 | 2.72 | Supplying all materials, labour, T&P for fitting and fixing and laying 100mm dia PVC plain bend with door of appd. make including supply of all jointing materials like Gaskets, adhesive, solvent, cement etc and fixing to walls with supply of wooden plugs and nails, bobbins, clamps including scaffolding and testing etc as per PH specification and direction of the Engineer in charges (Make :- Oriplast / Supreme) | BI01010001010000000000000515BI0100001284 | 4 | Each |
| 174 | 2.73 | Supplying all materials, labour, T&P for fitting and fixing and laying 75mm dia PVC plain bend with door of appd. make including supply of all jointing materials like Gaskets, adhesive, solvent, cement etc and fixing to walls with supply of wooden plugs and nails, bobbins, clamps including scaffolding and testing etc as per PH specification and direction of the Engineer in charges (Make :- Oriplast / Supreme) | BI01010001010000000000000515BI0100001285 | 6 | Each |
| 175 | 2.74 | Supplying all materials, labour, T&P for fitting and fixing and laying 100mm dia PVC 'P' trap Hubless of appd. make including supply of all jointing materials like Gaskets, adhesive, solvent, cement etc and fixing to walls with supply of wooden plugs and nails, bobbins, clamps including scaffolding and testing etc as per PH specification and direction of the Engineer in charges (Make :- Oriplast / Supreme) | BI01010001010000000000000515BI0100001286 | 2 | Each |
| 176 | 2.75 | Supplying all materials, labour, T&P for fitting and fixing and laying 100mm dia PVC cowl of appd. make including supply of all jointing materials like Gaskets, adhesive, solvent, cement etc and fixing to walls with supply of wooden plugs and nails, bobbins, clamps including scaffolding and testing etc as per PH specification and direction of the Engineer in charges (Make :- Oriplast / Supreme) | BI01010001010000000000000515BI0100001287 | 5 | Each |
| 177 | 2.76 | Supplying all materials, labour, T&P for fitting and fixing and laying 100mm dia sheldede S/S coupling with EPDM rubber of appd. make including nut & bolt supply of all jointing materials like Gaskets, adhesive, solvent, cement etc and fixing to walls with supply of wooden plugs and nails, bobbins, clamps including scaffolding and testing etc as per PH specification and direction of the Engineer in charges (Make :- Oriplast / Supreme) | BI01010001010000000000000515BI0100001288 | 6 | Each |
| 178 | 2.77 | Supplying all materials, labour, T&P for fitting and fixing and laying 75mm dia shieldede S/S coupling with EPDM rubber supply of all jointing materials like Gaskets, adhesive, solvent, cement etc and fixing to walls with supply of wooden plugs and nails, bobbins, clamps including scaffolding and testing etc as per PH specification and direction of the Engineer in charges (Make:- Oriplast / Supreme) | BI01010001010000000000000515BI0100001289 | 11 | Each |
| 179 | 2.78 | Supplying all materials, labour, T&P for fitting and fixing and laying WC Connector long of appd. make including supply of all jointing materials like Gaskets, adhesive, solvent, cement etc and fixing to walls with supply of wooden plugs and nails, bobbins, clamps including scaffolding and testing etc as per PH specification and direction of the Engineer in charges (Make :- Oriplast / Supreme) | BI01010001010000000000000515BI0100001290 | 11 | Each |
| 180 | 2.79 | Supplying all materials, labour, T&P for fitting and fixing and laying 100mm dia C.I. plain bend 45D of appd. make including supply of all jointing materials like Gaskets, adhesive, solvent, cement etc and fixing to walls with supply of wooden plugs and nails, bobbins, clamps including scaffolding and testing etc as per PH specification and direction of the Engineer in charges (Make :- Oriplast / Supreme) | BI01010001010000000000000515BI0100001291 | 15 | Each |
| 181 | 2.8 | Providing and laying in trench cement concrete ( 1:4:8 ) with 40mm size hard granite metal in the following type of bedding for 160mm pvc pipes of the following internal diameter including curing complete as per specification and direction of EIC. | BI01010001010000000000000515BI0100001292 | 180 | Mtr |
| 182 | 2.81 | Providing all material, labour, T&P and construction of Gully Trap chamber of size as mentioned below with 250mm nominal size flyash Brick having crushing strength not less than 75kg/ sqcm in CM 1:4 over a bed of 100mm thick C.C. (1:3:6) using 40mm size HG metal, plastering with 12mm thick cement plaster with cement punning in cement mortar 1:4 on inner surface and 12mm thick cement plaster in cement mortar (1:4) on external surface,fitting & fixing of PVC Gully Trap and pre-cast factory made (SFRC) cover with frame of opening size 260mmx260mm, moulding and shaping the channel & benching with C.C (1:2:4) with hard granite chips 12mm size, earth work excavation in all kinds of soil & rock and filling the cavity of the chamber with excavated & selected earth levelling the surface around the chamber with disposal of surplus earth within 50mt lead as per specification, design & drawing including cost of curing and all royalty, cost, conveyance etc. but Excluding GST all complete as per specification & direction of EIC.\nInner size 300mmx300mmx450mm depth Gully Trap chamber | BI01010001010000000000000515BI0100001293 | 20 | Each |
| 183 | 2.82 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of (ASTRAL/AJAY/SUPREME) confirming to ASTM F442 Specific-2 having thermal stability for hot & cold water supply SDR 11 , including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 15 mm nominal outer dia Pipes GROUND FLOOR | BI01010001010000000000000515BI0100001294 | 80 | Mtr |
| 184 | 2.83 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of ( ASTRAL/AJAY/SUPREME) confirming to ASTM F442 Specific-2 having thermal stability for hot & cold water supply SDR 11 , including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal outer dia Pipes GROUND FLOOR | BI01010001010000000000000515BI0100001295 | 75 | Mtr |
| 185 | 2.84 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of ( ASTRAL/AJAY/SUPREME) confirming to ASTM F442 Specific-2 having thermal stability for hot & cold water supply SDR 11 , including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer dia Pipes GROUND FLOOR | BI01010001010000000000000515BI0100001296 | 55 | Mtr |
| 186 | 2.85 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of ( ASTRAL/AJAY/SUPREME) confirming to ASTM F442 Specific-2 having thermal stability for hot & cold water supply SDR 11 , including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 32 mm nominal outer dia Pipes GROUND FLOOR | BI01010001010000000000000515BI0100001297 | 70 | Mtr |
| 187 | 2.86 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of ( ASTRAL/AJAY/SUPREME) confirming to ASTM F442 Specific-2 having thermal stability for hot & cold water supply SDR 11 , including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 40 mm nominal outer dia Pipes GROUND FLOOR | BI01010001010000000000000515BI0100001298 | 40 | Mtr |
| 188 | 2.87 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of ( ASTRAL/AJAY/SUPREME) confirming to ASTM F442 Specific-2 having thermal stability for hot & cold water supply SDR 11 , including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 50 mm nominal outer dia Pipes GROUND FLOOR | BI01010001010000000000000515BI0100001299 | 90 | Mtr |
| 189 | 2.88 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of ( ASTRAL/AJAY/SUPREME) confirming to ASTM F442 Specific-2 having thermal stability for hot & cold water supply SDR 11 , including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 15 mm nominal outer dia Pipes FIRST FLOOR | BI01010001010000000000000515BI0100001300 | 30 | Mtr |
| 190 | 2.89 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of ( ASTRAL/AJAY/SUPREME) confirming to ASTM F442 Specific-2 having thermal stability for hot & cold water supply SDR 11 , including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal outer dia Pipes FIRST FLOOR | BI01010001010000000000000515BI0100001301 | 30 | Mtr |
| 191 | 2.9 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of ( ASTRAL/AJAY/SUPREME) confirming to ASTM F442 Specific-2 having thermal stability for hot & cold water supply SDR 11 , including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer dia Pipes FIRST FLOOR | BI01010001010000000000000515BI0100001302 | 15 | Mtr |
| 192 | 2.91 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of ( ASTRAL/AJAY/SUPREME) confirming to ASTM F442 Specific-2 having thermal stability for hot & cold water supply SDR 11 , including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 32 mm nominal outer dia Pipes FIRST FLOOR | BI01010001010000000000000515BI0100001303 | 15 | Mtr |
| 193 | 2.92 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of ( ASTRAL/AJAY/SUPREME) confirming to ASTM F442 Specific-2 having thermal stability for hot & cold water supply SDR 11 , including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 40 mm nominal outer dia Pipes FIRST FLOOR | BI01010001010000000000000515BI0100001304 | 50 | Mtr |
| 194 | 2.93 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes of ( ASTRAL/AJAY/SUPREME) confirming to ASTM F442 Specific-2 having thermal stability for hot & cold water supply SDR 11 , including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 50 mm nominal outer dia Pipes FIRST FLOOR | BI01010001010000000000000515BI0100001305 | 70 | Mtr |
| 195 | 2.94 | Cutting grooves in pucca floors and walls for taking GI/PVC /CPVC pipes including making good the damages caused with cost of all material,labour, scafolding, tools, plant, royalty etc. complete as per direction of EIC. | BI01010001010000000000000515BI0100001306 | 90 | Mtr |
| 196 | 2.95 | Providing all materials required for construction of manhole chamber with Fly Ash bricks of size 25cm x 12cm x 8cm having crushing strength not less than 75Kg/Sqcm in C.M (1:4), PCC 1:3:6 with 40mm size hard granite crusher broken metal of 200mm thick, 12mm thick cement plaster 1:3 both in outer & inner surface of the wall & bottom, earth work excavation in all kinds of soil/rock including back filling with selected excavated earth duly watered & rammed. RCC M-25 with 20mm & down size H.G crusher broken chips having minimum cube strength 200Kg/Sqcm at 28 days confirming to IS-453/76 & IS-3370 for roof slab of 150mm average thick with form work as per the requied size including cost for MS reinforcement as per approved design & drawing & fixing of Pre-cast factory made manhole cover with frame ( medium duty) for opening of 560mm including cost of all materials, labour, T&P etc. complete as per specification & direction of Engineer-in-charge. Manhole chamber of Inner size 900mmx800mmx 450mm depth. | BI01010001010000000000000515BI0100001307 | 5 | Each |
| 197 | 2.96 | Providing and placing on terrace (at all floor levels) 2000 litre polythelene water storage tank ISI 12701 marked with cover and suitable locking arrangement and making necessary holes for inlets outlet and overflow pipe along with roof top pedestral including all fittings complete as per direction of EIC/Architect Make-sintex | BI01010001010000000000000515BI0100001308 | 2 | Each |
| 198 | 2.97 | Providing and fixing 25mm dia CPVC ball valve of approved make and quality with all materials, labour, tools, plant, scafolding , making good the damages caused, complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001309 | 15 | Each |
| 199 | 2.98 | Providing and fixing 40mm dia CPVC BALL valve of approved make and quality with all materials, labour, tools, plant, scafolding , making good the damages caused etc complete as per direction of EIC/Architect. | BI01010001010000000000000515BI0100001310 | 7 | Each |
| 200 | 2.99 | Supplying all materials,labours,T&P and cutting holes through existing brickwork including making good the damages in cement mortar (1:4) for taking GI /CPVC /PVC pipes and fittings etc all complete as per PH specification and direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001311 | 40 | Each |
| 201 | 3 | Supplying and fixing Matrix set for differently abled series consisting of Wash Basin 46x36 cm with one pair mounting brackets, European Water closet and Cistern complete with fittings & ceat cover, over number hinged rail 76 cm & 4 nos. of grab rails 60 cm complete with all respect as per direction of Architect/ Engineer in charge.( Make Hindware CAT No.-70002) | BI01010001010000000000000515BI0100001312 | 4 | Each |
| 202 | 3.01 | Fixing bowl pattern urinal conforming to IS 2556 : Part 6-1996 including connecting the urinal of 330x310x420 mm size with waste pipe by means of white lead mixed with chopped hemp etc all complete as per specification. (JAQUAR ESSCO MAKE, ECS-WHT-253) | BI01010001010000000000000515BI0100001313 | 7 | Each |
| 203 | 3.02 | Providing and fixing Curved urinal partitions of size 450mm as per direction of Engineer -in-chief and finished smooth. (Jaquar make, CAT-JSE-CHR-810UC450X) | BI01010001010000000000000515BI0100001314 | 5 | Each |
| 204 | 4 | Electrical works | BI01010001010000000000000515BI0100001315 | ||
| 205 | 4.01 | Wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class 1.6 mm thick PVC flexiable conduit, with 6 amp modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC copper conductor cable etc as required .including all accesories and coonection as per direction of EIC (Length of point - 5 mtr) | BI01010001010000000000000515BI0100001316 | 210 | Each |
| 206 | 4.02 | Wiring to group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC flexiable insulated copper conductor single core cable in surface/ recessed 1.6 mm thick PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC copper conductor etc. as required. including all accesories and coonection as per direction of EIC (Length of Looping- 5 mtr) | BI01010001010000000000000515BI0100001317 | 153 | Each |
| 207 | 4.03 | Recessed wiring for 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in recess 20 mm dia non-metalic PVC flexible conduit with modular type switch ,4 module 18SWG modular GI box and earthing point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc. as required. including all accesories and coonection as per direction of EIC | BI01010001010000000000000515BI0100001318 | 35 | Each |
| 208 | 4.04 | Supplying and fixing of 4module GI box with cover on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 5 pin 15 / 16 amps socket outlet and 15 / 16 amps modular type switch, connection, painting etc as required including all accesories and coonection as per direction of EIC . | BI01010001010000000000000515BI0100001319 | 21 | Each |
| 209 | 4.05 | Recessed wiring to 2 nos 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in recess 20 mm dia non-metalic PVC flexible conduit with modular type 2 nos switch ,6 module 18SWG modular GI box and earthing point with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc. as required.including all accesories and coonection as per direction of EIC | BI01010001010000000000000515BI0100001320 | 9 | Each |
| 210 | 4.06 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding all acessoriesmodular plate labour ,t&p etc complete work asper direction of EIC. | BI01010001010000000000000515BI0100001321 | 70 | Each |
| 211 | 4.07 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. | BI01010001010000000000000515BI0100001322 | 40 | Each |
| 212 | 4.08 | Supply and fixing 15 / 20 amp socket outlet with 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in recess 20 mm dia non-metalic PVC flexible conduit with modular type switch ,4 module 18SWG modular GI box and earthing point with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor for loop earthing etc. as required. as required.including all accesories and coonection as per direction of EIC | BI01010001010000000000000515BI0100001323 | 25 | Each |
| 213 | 4.09 | Recessed sub main wiring with 2 Nos. Single Core 1.5 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Single Core 1.0 mm2 FRLS Copper Wire for Earth Continuity Conductor in 1.6 mm thick 20 mm dia PVC flexiable conduity pipe as per SLD complete with making good the damages caused as required and including all accesories and coonection as per Direction of Engineer-In-Charge. | BI01010001010000000000000515BI0100001324 | 500 | Mtr |
| 214 | 4.1 | Recessed sub main wiring with 2 Nos. Single Core 2.5 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Single Core 1.5 mm2 FRLS Copper Wire for Earth Continuity Conductor 1.6 mm thick 20 mm dia PVC flexiable conduity pipe as per SLD complete with making good the damages caused as required and including all accesories and coonection as per Direction of Engineer-In-charge. | BI01010001010000000000000515BI0100001325 | 700 | Mtr |
| 215 | 4.11 | Recessed sub main wiring with 2 Nos. Single Core 4.0 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Single Core 2.5 mm2 FRLS Copper Wire for Earth Continuity Conductor 1.6 mm thick 20 mm dia PVC flexiable conduity pipe as per SLD complete with making good the damages caused as required and including all accesories and coonection as per Direction of Engineer-In-charge. | BI01010001010000000000000515BI0100001326 | 450 | Mtr |
| 216 | 4.12 | Recessed sub main wiring with 2 Nos. Single Core 6.0 mm2 FRLS Copper Wire for Phase and Neutral and 1 No. Single Core 6 mm2 FRLS Copper Wire for Earth Continuity Conductor a1.6 mm thick 20 mm dia PVC flexiable conduity pipe as per SLD complete with making good the damages caused as required and including all accesories and coonection as per Direction of Engineer-In-charge. | BI01010001010000000000000515BI0100001327 | 450 | Mtr |
| 217 | 4.13 | Recessed sub main wiring with 4 Nos. Single Core 16.0 mm2 FRLS Copper Wire for Phase and Neutral and 2 Nos. Single Core 10 mm2 FRLS Copper Wire for Earth Continuity Conductor 1.6 mm thick 25 mm dia PVC flexiable conduity pipe as per SLD complete with making good the damages caused as required and including all accesories and coonection as per Direction of Engineer-In-charge. | BI01010001010000000000000515BI0100001328 | 250 | Mtr |
| 218 | 4.14 | Supply, delivery, installation and testing of Telephone Outlet Boards containing a Clip-in type Modular Telephone Socket with Top fixed on GI concealed Modular Switch Board including Connections & making good the damages caused complete as required and as per Direction of Engineer-In-Charge. | BI01010001010000000000000515BI0100001329 | 5 | Each |
| 219 | 4.15 | Recessed Wiring to Telephone Socket Outlet from Junction Box with 0.5 mm2 Twin Pair Copper Conductor Telephone Wire run inside prelaid PVC Conduit complete including termination, testing etc complete as required and as per Direction of Engineer-In-Charge. ( Make of wire Finolex / Anchor / Havells /KEI) | BI01010001010000000000000515BI0100001330 | 120 | Mtr |
| 220 | 4.16 | Supply, delivery, installation and testing of TV Antenna Outlet Boards containing a Modular type TV Antenna Socket fixed on Modular Concealed Box ncluding all accesories and coonectionmaking good the damages caused complete as required and as per Direction of Engineer-In-Charge. | BI01010001010000000000000515BI0100001331 | 4 | Each |
| 221 | 4.17 | Supply, delivery, installation and testing of TV Antenna Wires RG6 in PVC Pipe and making good the damages caused ncluding all accesories and coonection complete as required and as per Direction of Engineer-In-Charge. ( Make of wire Finolex / Anchor / Havells /Polycab/KEI/L&T)\n | BI01010001010000000000000515BI0100001332 | 120 | Mtr |
| 222 | 4.18 | Supply and laying of 20 mm dia 1.6 mm thickness flexible PVC conduits cocealed in wall/column/roof slab of the building along with all accessories and 18 SWG GI fish wire complete for telephone/TV/computer/circuit or sub main wiring as required & as per diretion of EIC. | BI01010001010000000000000515BI0100001333 | 70 | Mtr |
| 223 | 4.19 | Supply and laying of 25 mm dia 1.6 mm thickness flexible PVC conduits cocealed in wall/column/roof slab of the building along with all accessories and 18 SWG GI fish wire complete for telephone/TV/computer/circuit or sub main wiring as required & as per diretion of EIC. | BI01010001010000000000000515BI0100001334 | 70 | Mtr |
| 224 | 4.2 | Supplying, delivery, installation, testing and commissioning of Flush mounted Cat 6 DUAL Information Outlet Box. including termination, testing etc complete as required and as per Direction of Engineer-In-Charge. | BI01010001010000000000000515BI0100001335 | 6 | Each |
| 225 | 4.21 | Supplying, laying of UTP 4 PAIR Cat 6 LAN Wire in the existing surace/recessed PVC Pipe as required. including termination, testing etc complete as required and as per Direction of Engineer-In-Charge. | BI01010001010000000000000515BI0100001336 | 100 | Mtr |
| 226 | 4.22 | Light Distribution Board Supply installation testing & commisioning of 12 way SPN DB glazed door with IP-43 consisting of 1 Nos. of 32 Amp DP RCCB, 30 mA as incoming unit and 10 Nos. of 6 Amp SP MCB, c-curve as outgoing unit.etc complete as required and as per Direction of Engineer-In-Charge | BI01010001010000000000000515BI0100001337 | 9 | Set. |
| 227 | 4.23 | Supply installation testing & commisioning of 6 way TPN DB glazed door with IP-43 consisting of 1 Nos. of 63 Amp FP MCB, 10 KA as incoming unit and 18 Nos. of 10 Amp SP MCB, C-curve , 10 KA as outgoing unit.etc complete as required and as per Direction of Engineer-In-Charge(for indoor unit VRV AC) | BI01010001010000000000000515BI0100001338 | 1 | Set. |
| 228 | 4.24 | Main Distribution Board Supply and Fixing of L.T indoor type wall mounted panel board of required size with 16 SWG MS sheet including front & end Enclousers, locking arrangement, painting, fabrication work,mutifunctional meter with V,A,F,PF, R-Y-B indicator, Voltmeter-Ammeter for both incoming & out going, selector switch for both, required wiring, cable gland & socket of required size & concreting work with all accessories, cost of labour, T&P etc as per direction of EIC. INCOMING:400 amp 3P ACB 50 KA Thermal Magentic release type, 400 AMP CHANGOVER Switch with Provision of CO switch status outgoing 2 nos of 200 Amp. FP MCCB 50 KA, 4 nos of 63 Amp. FP MCB 10 KA ,9 nos of 32 Amp. DP MCB 10 KA | BI01010001010000000000000515BI0100001339 | 1 | Each |
| 229 | 4.25 | S/F of HVAC panel with RYB indicator, required wiring, mutifunctional meter with V,A,F,PF, cable gland of required size & concreating works with all accessories, labour cost, T&P etc as per direction of EIC.Incoming :160A 4P MCCB 25 KA ,outgoing 3 no 63A 4P MCCB 18 KA, | BI01010001010000000000000515BI0100001340 | 1 | Each |
| 230 | 4.26 | Fittings and Fixtures Supplying, installation, testing and commissioning of 150 watt, 240 VOLT LED high bay light complete fitting ISI marked including all accessories, labour cost, T&P etc complete work as per Direction of EIC. | BI01010001010000000000000515BI0100001341 | 16 | Each |
| 231 | 4.27 | Supplying, installation, testing and commissioning of 100 watt 240 VOLT LED flood light complete fitting ISI marked including all accessories, labour cost, T&P etc complete work as per Direction of EIC. | BI01010001010000000000000515BI0100001342 | 7 | Each |
| 232 | 4.28 | Supplying, installation, testing and commissioning of 20 watt 240 VOLT LED tube light complete fitting ISI marked including all accessories, labour cost, T&P etc complete work as per Direction of EIC. | BI01010001010000000000000515BI0100001343 | 154 | Each |
| 233 | 4.29 | Supplying, installation, testing and commissioning of 50 watt 240 VOLT LED flood light complete fitting ISI marked including all accessories, labour cost, T&P etc complete work as per Direction of EIC. | BI01010001010000000000000515BI0100001344 | 6 | Each |
| 234 | 4.3 | Supplying, installation, testing and commissioning of 45 watt outdoor type 240 VOLT LED premises light complete fitting ISI marked including all accessories, labour cost, T&P etc complete work as per Direction of EIC | BI01010001010000000000000515BI0100001345 | 20 | Each |
| 235 | 4.31 | Supplying, installation, testing and commissioning of 10 watt outdoor type 240 VOLT LED Bollard light complete fitting ISI marked including all accessories, labour cost, T&P etc complete work as per Direction of EIC. | BI01010001010000000000000515BI0100001346 | 18 | Each |
| 236 | 4.32 | Supplying, installation, testing and commissioning of 75 watt 240 VOLT LED indoor strip lightcomplete fitting ISI marked including all accessories, labour cost, T&P etc complete work as per Direction of EIC. | BI01010001010000000000000515BI0100001347 | 15 | Each |
| 237 | 4.33 | Supplying, installation, testing and commissioning of 5 watt 240 volt LED FOOT LIGHT lightcomplete fitting ISI marked including all accessories, labour cost, T&P etc complete work as per Direction of EIC.Make :CG /Havells/Phillips | BI01010001010000000000000515BI0100001348 | 50 | Each |
| 238 | 4.34 | Supply, installation & testing of following 380 MM Speed HEAVY DUTY Exhaust Fan 3250 CMH AIR DELIVERY on Existing Sheet Metal Switch Board including loop connections and making good the damages caused complete as required and as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001349 | 22 | Each |
| 239 | 4.35 | Supply, installation and testing of following 1200 MM Sweeps of High Speed Energy Efficient 240 CMM AIR DELIVERY ISI & BEE 5 STAR A.C. Ceiling Fan complete with Fan Blades, Down Rod, Canopies & Capacitor etc. including supply of Sundry Materials, making connection from the suitable point outlet but excluding cost of Fan Regulator complete as required and as per the Direction of Engineer-In-Charge | BI01010001010000000000000515BI0100001350 | 70 | Each |
| 240 | 4.36 | Supply, installation & testing of following 400 MM HIGH Speed SWEEP WALL Mounted Fan on Existing Sheet Metal Switch Board including loop connections and making good the damages caused complete as required and as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001351 | 30 | Each |
| 241 | 4.37 | Earthing Providing and fixing 4.00 sq mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. including all accessories, labour cost, T&P etc complete work as per Direction of EIC. | BI01010001010000000000000515BI0100001352 | 120 | Mtr |
| 242 | 4.38 | supply and fixing of Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.including all accessories, labour cost, T&P etc complete work as per Direction of EIC. | BI01010001010000000000000515BI0100001353 | 7 | Mtr |
| 243 | 4.39 | supply and fixing of 95 Sq. mm 4 core XLPE insulated 1.1 KV armoured cable in ground including excavation,sand cushining,protective covering and refilling of trench ett as required.including all accessories, labour cost, T&P etc complete work as per Direction of EIC.make: polycab/finolex/KEI | BI01010001010000000000000515BI0100001354 | 100 | Mtr |
| 244 | 4.4 | LT Overhead line Supply and fixing of 9 Mtr long SIZE 116mm X 100 mm X 6mm RS Joist pole with Concreating of Supports C.C-1:4:8 using 40mm BHG metal size- 5.5'x2'x2'=22CFT=0.62Cum Padding 900x600x150mm =0.081Cum. Total=0.701Cum @Rs4306.70 and Coupling of support section 15\"x15\" (3.9Cft) height 2'-6' (1'-6\" above G.L & 1'-0' below G.L) in C.C. 1:2:4 using 12mm BHG metal & curing for 5 days.including all accessories, labour cost, T&P etc complete work as per Direction of EIC | BI01010001010000000000000515BI0100001355 | 15 | Each |
| 245 | 4.41 | Supply & drawal of 3X95+1X50+1X16 Sq mm XLPE AB cable including all accessories, labour cost, T&P etc complete work as per Direction of EIC. | BI01010001010000000000000515BI0100001356 | 475 | Mtr |
| 246 | 4.42 | Supply & Fixing of Suspention type clamp with I hook for AB cable including all accessories, labour cost, T&P etc complete work as per Direction of EIC. | BI01010001010000000000000515BI0100001357 | 15 | Each |
| 247 | 4.43 | Supply & Fixing of LT conductor dead end clamp for AB cable including all associries, labour cost, T&P etc complete work as per Direction of EIC. | BI01010001010000000000000515BI0100001358 | 4 | Each |
| 248 | 4.44 | Supply, Installation & comissioning of complete LT stay set with stay Insulator, stay Clamp and fixing and concreating of stay set with 0.5Cum cement concret foundation of size 900x600x900mm including earth excavation work, all associries, labour cost, T&P etc complete work as per the direction of EIC. | BI01010001010000000000000515BI0100001359 | 5 | Each |
| 249 | 4.45 | Sundries for survey, Tree Cutting, small size nut bolt, Aluminium binding wire/tape & Danger board etc. | BI01010001010000000000000515BI0100001360 | 1 | Each |
| 250 | 4.46 | Lightning Protection System Supply & installation of Early Streamer Emission (ESE) type Lightning Protection complete with the Lightning Air Terminal - works on dual thrust design which is comprised of separate electrically isolated dual panels (Copper Material) surrounding an earthed central Solid brass finial. As per NF C 17 -102 (2011) NEW STANDARD,ESE termina listested & certified for the below parameters.\n• Tested for performace of ESE Air Terminal in Europen accrediatedlabasperNFC17-102:2011.\n• Tested & certified by CPRI (Central Power Research Institute), Govt of India for the Impulse current of 40 KA with 5 positive & 5 negative impulse.\n• The serial number displayed on the ESE lightning arrester is duly supported with the quality certificate from Australian manufacture. *Warranty:05years.\nProtection Radius : 68Mtr Level I & 95 mtrs @ Level IV (Standard) @ 5mtr Height including all associries, labour cost, T&P etc complete work as per Direction of EIC.\n\n\n\n\n | BI01010001010000000000000515BI0100001361 | 1 | Each |
| 251 | 4.47 | Supply & installation of mounting mast used to support the lightning air terminal shall either be a supporting mast or Free standing mast at a minimum height of 5 metres above to be area protected or as per required level of protection. The mounting pole and supports shall be securely fixed with base plate and PVC coated guy wires where required to withstand maximum locally recorded wind velocity. Mounting Pole shall be non corrosive. The down conductor shall pass through the centre of the pole for the entire length of the pole.including all associries, labour cost, T&P etc complete work as per Direction of EIC. Model: Supporting G.I Guyed Mast 05Mtr with PVC coated Guying wire, Uclamps & SS Anchor astners.\nNote : Required radius of protection will be achieved with 5Mtr mast.\n | BI01010001010000000000000515BI0100001362 | 1 | Each |
| 252 | 4.48 | Supply and fixing of down conductor consist of copper conductor of 70Sqmm cross section and having min 900Nos of copper strands. Copper Conductor should be insulated with min.2mm thick PVC insulation and it should be tested as per IS standard. S.S saddles should be used at every 0.5mtr run. Model: 70Sq.mm Copper cable with SS saddling features.including all associries, labour cost, T&P etc complete work as per Direction of EIC. | BI01010001010000000000000515BI0100001363 | 50 | Mtr |
| 253 | 4.49 | Supply and Fixing of maintenance free Safe Earthing Electrodes with ISI G.I. pipe dia 75mm as Secondary electrode with wall thickness of 2.6 mm and the Primary Earthing Electrode will be 50mm X 6mm X 1no M.S. hot dipped galvanized strip filled with a highly conductive & non-corrosive compound in between the Primary Earthing and the secondary Earthing, the Surface Area in mm will be 3,36,000 for 3mtrs length and Cross Sectional Primary conducting area is 300 sq.mm. An Solid G.I. Base plat seals the unit at the bottom.including all associries, labour cost, T&P etc complete work as per Direction of EIC. | BI01010001010000000000000515BI0100001364 | 4 | Each |
| 254 | 4.5 | Supply and fixing of MES-GFC chemical ground compound of 25Kg in each bag.including all associries, labour cost, T&P etc complete work as per Direction of EIC. | BI01010001010000000000000515BI0100001365 | 4 | Bags |
| 255 | 4.51 | Supply and fixing of Lightning Strike recorder( 6 digits Display) of non-resettable type in an IP-67 enclosure with the minimum sensitivity of 1000 A & maximum capacity of 220 KA ( 8/20 microsec wave form) tested as per IEC 60-1:1989. including all associries, labour cost, T&P etc complete work as per Direction of EIC.\n | BI01010001010000000000000515BI0100001366 | 1 | Each |
| 256 | 4.52 | VRV SYSTEM Supplying, installation, testing and commissioning of Full Inverter VRF System with Modular type outdoor units (Top Discharge) , all scroll DC Inverter compressors for Cooling & Heating applications along with different types of indoors compitable with VRF ODUs with R 410 A . All inverter capacity controlling compressors shall be suitable for 3 Phase, 50 Hz. It includes additional Refrigerant and Outdoor base. The outdoor fins should be with corrosion resistant chemical coating at factory only alongwith hydrophilic coating to shield it from Salt, Sand & other elements brought in by the air. It can work upto 52 Degree Celsius. All proposed outdoor unit should have minimum COP of 3.7 at 100% load condition for Cooling in standard AHRI test conditions (Ambient DBT-35 Deg C, Inside DBT 27 Def C/WBT 19 Deg C). Proposed outdoor unit system should not have any deration in cooling capacity upto 39 Degree C ambient temepetrure.making good the damages caused complete as required and as per direction of Engineer-in-charge..16 HP (8HP + 8 HP) | BI01010001010000000000000515BI0100001367 | 1 | Each |
| 257 | 4.53 | VRV SYSTEM Supplying, installation, testing and commissioning of Full Inverter VRF System with Modular type outdoor units (Top Discharge) , all scroll DC Inverter compressors for Cooling & Heating applications along with different types of indoors compitable with VRF ODUs with R 410 A . All inverter capacity controlling compressors shall be suitable for 3 Phase, 50 Hz. It includes additional Refrigerant and Outdoor base. The outdoor fins should be with corrosion resistant chemical coating at factory only alongwith hydrophilic coating to shield it from Salt, Sand & other elements brought in by the air. It can work upto 52 Degree Celsius. All proposed outdoor unit should have minimum COP of 3.7 at 100% load condition for Cooling in standard AHRI test conditions (Ambient DBT-35 Deg C, Inside DBT 27 Def C/WBT 19 Deg C). Proposed outdoor unit system should not have any deration in cooling capacity upto 39 Degree C ambient temepetrure.making good the damages caused complete as required and as per direction of Engineer-in-charge.28 HP (14HP + 14 HP) 34 HP | BI01010001010000000000000515BI0100001368 | 1 | Each |
| 258 | 4.54 | Supplying, installation, testing and commissioning of the Cassette type Indoor units suitable for operation on 220V-240V, Single Phase, 50 Hz AC electric supply and shall with washable Filters,BLDC motors.making good the damages caused complete as required and as per direction of Engineer-in-charge.1.5 TR ( 950x950) | BI01010001010000000000000515BI0100001369 | 2 | Each |
| 259 | 4.55 | Supplying, installation, testing and commissioning of the Cassette type Indoor units suitable for operation on 220V-240V, Single Phase, 50 Hz AC electric supply and shall with washable Filters,BLDC motors.making good the damages caused complete as required and as per direction of Engineer-in-charge 2.0 TR ( 950x950) | BI01010001010000000000000515BI0100001370 | 2 | Each |
| 260 | 4.56 | Supplying, installation, testing and commissioning of the Cassette type Indoor units suitable for operation on 220V-240V, Single Phase, 50 Hz AC electric supply and shall with washable Filters,BLDC motors.making good the damages caused complete as required and as per direction of Engineer-in-charge.2.5 TR ( 950x950) | BI01010001010000000000000515BI0100001371 | 9 | Each |
| 261 | 4.57 | Supplying, installation, testing and commissioning of the Hi-Wall type Indoor units suitable for operation on 220V-240V, Single Phase, 50 Hz AC electric supply and shall with washable Filters,BLDC motors.making good the damages caused complete as required and as per direction of Engineer-in-charge .1.00 TR | BI01010001010000000000000515BI0100001372 | 2 | Each |
| 262 | 4.58 | Supplying, installation, testing and commissioning of the Hi-Wall type Indoor units suitable for operation on 220V-240V, Single Phase, 50 Hz AC electric supply and shall with washable Filters,BLDC motors.making good the damages caused complete as required and as per direction of Engineer-in-charge. 1.5 TR | BI01010001010000000000000515BI0100001373 | 1 | Each |
| 263 | 4.59 | Supplying, installation, testing and commissioning of Cassette Panel making good the damages caused complete as required and as per direction of Engineer-in-charge . | BI01010001010000000000000515BI0100001374 | 13 | Each |
| 264 | 4.6 | Supplying, installation, testing and commissioning of Wireless Remote making good the damages caused complete as required and as per direction of Engineer-in-charge . | BI01010001010000000000000515BI0100001375 | 16 | Each |
| 265 | 4.61 | Supplying, installation, testing and commissioning of Cooper Y-Branches/Refnets | BI01010001010000000000000515BI0100001376 | 16 | Each |
| 266 | 4.62 | Supply,Installation Shifting,Testing & commissioning of Ceiling concealed Air Cooled Inverter Duct able Split Type Air Conditioner with R 410 A Refrigerant Gas having DC Scroll Compressor housed inside the Out Door Unit of the plant having micro processor based control panel for operation.Providing & Connecting canvas in mouthpiece & ODU stand .It should be BLDC fan motor with Electronic Expansion Valve. Machine can operate up to 53 Deg Celsius ambient temperature suitable for operation on 415 V + 10%,50 Hz, 3 phase AC.making good the damages caused complete as required and as per direction of Engineer-in-charge. 11.0 TR | BI01010001010000000000000515BI0100001377 | 3 | Each |
| 267 | 4.63 | Supply,Installation Shifting,Testing & commissioning of Ceiling concealed Air Cooled Inverter Duct able Split Type Air Conditioner with R 410 A Refrigerant Gas having DC Scroll Compressor housed inside the Out Door Unit of the plant having micro processor based control panel for operation.Providing & Connecting canvas in mouthpiece & ODU stand .It should be BLDC fan motor with Electronic Expansion Valve. Machine can operate up to 53 Deg Celsius ambient temperature suitable for operation on 415 V + 10%,50 Hz, 3 phase AC.making good the damages caused complete as required and as per direction of Engineer-in-charge.5.5 TR | BI01010001010000000000000515BI0100001378 | 2 | Each |
| 268 | 4.64 | Supplay, Installation, Testing & Commissioning of the Copper refrigerant pipes with 19mm with nitrile rubber tube insulation of following sizes.making good the damages caused complete as required and as per direction of Engineer-in-charge. 41.3mm | BI01010001010000000000000515BI0100001379 | 5 | Mtr |
| 269 | 4.65 | Supplay, Installation, Testing & Commissioning of the Copper refrigerant pipes with 19mm with nitrile rubber tube insulation of following sizes.making good the damages caused complete as required and as per direction of Engineer-in-charge. 38.1mm | BI01010001010000000000000515BI0100001380 | 5 | Mtr |
| 270 | 4.66 | Supplay, Installation, Testing & Commissioning of the Copper refrigerant pipes with 19mm with nitrile rubber tube insulation of following sizes.making good the damages caused complete as required and as per direction of Engineer-in-charge.34.9mm | BI01010001010000000000000515BI0100001381 | 40 | Mtr |
| 271 | 4.67 | Supplay, Installation, Testing & Commissioning of the Copper refrigerant pipes with 19mm with nitrile rubber tube insulation of following sizes.making good the damages caused complete as required and as per direction of Engineer-in-charge.31.8mm | BI01010001010000000000000515BI0100001382 | 40 | Mtr |
| 272 | 4.68 | Supplay, Installation, Testing & Commissioning of the Copper refrigerant pipes with 19mm with nitrile rubber tube insulation of following sizes.making good the damages caused complete as required and as per direction of Engineer-in-charge.28.58mm | BI01010001010000000000000515BI0100001383 | 60 | Mtr |
| 273 | 4.69 | Supplay, Installation, Testing & Commissioning of the Copper refrigerant pipes with 19mm with nitrile rubber tube insulation of following sizes.making good the damages caused complete as required and as per direction of Engineer-in-charge.25.2mm | BI01010001010000000000000515BI0100001384 | 10 | Mtr |
| 274 | 4.7 | Supplay, Installation, Testing & Commissioning of the Copper refrigerant pipes with 19mm with nitrile rubber tube insulation of following sizes.making good the damages caused complete as required and as per direction of Engineer-in-charge.22.2mm | BI01010001010000000000000515BI0100001385 | 20 | Mtr |
| 275 | 4.71 | Supplay, Installation, Testing & Commissioning of the Copper refrigerant pipes with 19mm with nitrile rubber tube insulation of following sizes.making good the damages caused complete as required and as per direction of Engineer-in-charge.19.05mm | BI01010001010000000000000515BI0100001386 | 30 | Mtr |
| 276 | 4.72 | Supplay, Installation, Testing & Commissioning of the Copper refrigerant pipes with 19mm with nitrile rubber tube insulation of following sizes.making good the damages caused complete as required and as per direction of Engineer-in-charge.15.88mm | BI01010001010000000000000515BI0100001387 | 60 | Mtr |
| 277 | 4.73 | Supplay, Installation, Testing & Commissioning of the Copper refrigerant pipes with 19mm with nitrile rubber tube insulation of following sizes.making good the damages caused complete as required and as per direction of Engineer-in-charge.12.7mm | BI01010001010000000000000515BI0100001388 | 80 | Mtr |
| 278 | 4.74 | Supplay, Installation, Testing & Commissioning of the Copper refrigerant pipes with 13mm with nitrile rubber tube insulation of following sizes.making good the damages caused complete as required and as per direction of Engineer-in-charge.19.05mm | BI01010001010000000000000515BI0100001389 | 85 | Mtr |
| 279 | 4.75 | Supplay, Installation, Testing & Commissioning of the Copper refrigerant pipes with 13mm with nitrile rubber tube insulation of following sizes.making good the damages caused complete as required and as per direction of Engineer-in-charge.15.88mm | BI01010001010000000000000515BI0100001390 | 60 | Mtr |
| 280 | 4.76 | Supplay, Installation, Testing & Commissioning of the Copper refrigerant pipes with 13mm with nitrile rubber tube insulation of following sizes.making good the damages caused complete as required and as per direction of Engineer-in-charge.12.7mm | BI01010001010000000000000515BI0100001391 | 30 | Mtr |
| 281 | 4.77 | Supplay Installation, Testing & Commissioning of the Copper refrigerant pipes with 13mm with nitrile rubber tube insulation of following sizes.making good the damages caused complete as required and as per direction of Engineer-in-charge.9.52mm | BI01010001010000000000000515BI0100001392 | 110 | Mtr |
| 282 | 4.78 | Supplay, Installation, Testing & Commissioning of the Copper refrigerant pipes with 13mm with nitrile rubber tube insulation of following sizes.making good the damages caused complete as required and as per direction of Engineer-in-charge.6.4mm | BI01010001010000000000000515BI0100001393 | 55 | Mtr |
| 283 | 4.79 | Supply & Installation Testing and Commission of Control wiring of 2 core x 1.5 sqmm copper cable through suitable conduits in between indoor and outdoor units.making good the damages caused complete as required and as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001394 | 600 | Mtr |
| 284 | 4.8 | Supply, Installation, Testing and Commissioning of hard PVC drain pipe with 9mm thick nytrile tube insulation.making good the damages caused complete as required and as per direction of Engineer-in-charge.(With necessary Elbow, Sockets & Reducers.)25mm inner dia | BI01010001010000000000000515BI0100001395 | 20 | Mtr |
| 285 | 4.81 | Supply, Installation, Testing and Commissioning of hard PVC drain pipe with 9mm thick nytrile tube insulation.making good the damages caused complete as required and as per direction of Engineer-in-charge.(With necessary Elbow, Sockets & Reducers.) 32mm inner dia | BI01010001010000000000000515BI0100001396 | 120 | Mtr |
| 286 | 4.82 | Supply, Installation, Testing and Commissioning of hard PVC drain pipe with 9mm thick nytrile tube insulation.making good the damages caused complete as required and as per direction of Engineer-in-charge.(With necessary Elbow, Sockets & Reducers.)40mm inner dia | BI01010001010000000000000515BI0100001397 | 25 | Mtr |
| 287 | 4.83 | Supply, Installation, Testing and Commissioning of hard PVC drain pipe with 9mm thick nytrile tube insulation.making good the damages caused complete as required and as per direction of Engineer-in-charge.(With necessary Elbow, Sockets & Reducers.50mm inner dia | BI01010001010000000000000515BI0100001398 | 10 | Mtr |
| 288 | 4.84 | Supply & Installation of GI Slotted Tray for expose copper piping covered with GI sheet(22 SWG) on terrace & in shaft if open.making good the damages caused complete as required and as per direction of Engineer-in-charge. Supply, Installation, Testing and Commissioning of hard PVC drain pipe with 9mm thick nytrile tube insulation.making good the damages caused complete as required and as per direction of Engineer-in-charge.(With necessary Elbow, Sockets & Reducers.)50mmx300mm X 50mm | BI01010001010000000000000515BI0100001399 | 10 | Mtr |
| 289 | 4.85 | Supply & Installation of GI Slotted Tray for expose copper piping covered with GI sheet(22 SWG) on terrace & in shaft if open.making good the damages caused complete as required and as per direction of Engineer-in-charge.Supply, Installation, Testing and Commissioning of hard PVC drain pipe with 9mm thick nytrile tube insulation.making good the damages caused complete as required and as per direction of Engineer-in-charge.(With necessary Elbow, Sockets & Reducers.)25mmx150mm X 25mm | BI01010001010000000000000515BI0100001400 | 25 | Mtr |
| 290 | 4.86 | Supplying, installation, testing and commissioning Refrigerant copper piping inter connecting respective condensing unit& Evaporator units with refrigerant grade hard drawn copper tubes complete with insulation and all fittings.making good the damages caused complete as required and as per direction of Engineer-in-charge. Suction line 22.2 mm(For 11.0 TR Ductable AC) | BI01010001010000000000000515BI0100001401 | 30 | Mtr |
| 291 | 4.87 | Supplying, installation, testing and commissioning Refrigerant copper piping inter connecting respective condensing unit& Evaporator units with refrigerant grade hard drawn copper tubes complete with insulation and all fittings.making good the damages caused complete as required and as per direction of Engineer-in-charge.Liquid line 12.7 mm (For 11.0 TR Ductable AC) | BI01010001010000000000000515BI0100001402 | 30 | Mtr |
| 292 | 4.88 | Supplying, installation, testing and commissioning Refrigerant copper piping inter connecting respective condensing unit& Evaporator units with refrigerant grade hard drawn copper tubes complete with insulation and all fittings.making good the damages caused complete as required and as per direction of Engineer-in-charge.Suction line 19.05 mm (For 5.5 TR Ductable AC) | BI01010001010000000000000515BI0100001403 | 20 | Mtr |
| 293 | 4.89 | Supplying, installation, testing and commissioning Refrigerant copper piping inter connecting respective condensing unit& Evaporator units with refrigerant grade hard drawn copper tubes complete with insulation and all fittings.making good the damages caused complete as required and as per direction of Engineer-in-charge. Liquid line 9.52 mm (For 5.5 TR Ductable AC) | BI01010001010000000000000515BI0100001404 | 20 | Mtr |
| 294 | 4.9 | Installation with supply of Supports/suspension of condensing unit & Evaporator unit including ribbed neoprene VI pads for Ductable AC. making good the damages caused complete as required and as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001405 | 5 | Set |
| 295 | 4.91 | supply and fixing of Hard PVC drain pipe of 32mm dia with 6mm nyitrile insulation. | BI01010001010000000000000515BI0100001406 | 25 | Mtr |
| 296 | 4.92 | Design, supply, fabrication & erection of air distribution GSS Ducting in accordance with the approved ducting lay out drawing, complete with all accessories, dampers, guide vanes, support, etc.making good the damages caused complete as required and as per direction of Engineer-in-charge.24 G GP Sheet | BI01010001010000000000000515BI0100001407 | 275 | Sqm |
| 297 | 4.93 | Design, supply, fabrication & erection of air distribution GSS Ducting in accordance with the approved ducting lay out drawing, complete with all accessories, dampers, guide vanes, support, etc.making good the damages caused complete as required and as per direction of Engineer-in-charge.22 G GP Sheet | BI01010001010000000000000515BI0100001408 | 75 | Sqm |
| 298 | 4.94 | Supplying, installation, testing and commissioning OFAcoustic insulation inside the SA Ducts with 12 mm thick F.G., Tissue paper & 32 G Aluminum perforated sheet.making good the damages caused complete as required and as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001409 | 85 | Sqm |
| 299 | 4.95 | Providing insulation over the S/A duct with 13 mm thick aluminum foil faced nitrile insulation fix with proper adhesive.making good the damages caused complete as required and as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001410 | 285 | Sqm |
| 300 | 4.96 | Supplying, installation, testing and commissioning of Dynacraft/Premeer/carryair or equivalent make linear grills or extruded aluminium section finished with power coated or approved colour.making good the damages caused complete as required and as per direction of Engineer-in-charge.Supply air & Return AIR Grills/Diffuser | BI01010001010000000000000515BI0100001411 | 4 | Sqm |
| 301 | 4.97 | Supplying, installation, testing and commissioning of Dynacraft/Premeer/carryair or equivalent make linear grills or extruded aluminium section finished with power coated or approved colour.making good the damages caused complete as required and as per direction of Engineer-in-charge. VCD | BI01010001010000000000000515BI0100001412 | 2.5 | Sqm |
| 302 | 4.98 | Laying control copper wire outdoor unit to in door unit as required to complete the work in all respect.making good the damages caused complete as required and as per direction of Engineer-in-charge. 6c. X 1.5Sqmm | BI01010001010000000000000515BI0100001413 | 55 | Mtr |
| 303 | 5 | EXTINGUISHER SYSTEM ABC Dry Powder Fire Extinguisher 4 Kg apacity mfd to IS: 15683 with BIS mark, Brass forged squeeze lever discharge valve CE-EN3 MARKED, fitted with pressure indicating guage (CE MARK - EN3 APPROVED) , discharge hose with nozzle, duly charged with ISI Marked 90 % MONO AMONIUM PHOSPHATE (MAP) SILICONISED powder, pressurized with Nitrogen Gas,wall mounting bracket & screw. FIRE RATING - 2A, 21B WARRANTY 5 YEAR as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001415 | 20 | Each |
| 304 | 5.01 | Clean agent Fire Extinguisher 2 Kg apacity mfd to IS: 15683 with BIS mark, Brass forged squeeze lever discharge valve CE-EN3 MARKED, fitted with pressure indicating guage (CE MARK - EN3 APPROVED) , discharge hose with nozzle, duly charged with wall mounting bracket & screw. FIRE RATING - 1A, 8B WARRANTY 5 YEAR as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001416 | 1 | Each |
| 305 | 5.02 | AUTOMATIC FIRE ALARMING AND DETECTION SYSTEM Supplying, installation, testing and commissioning of Vds approved 32 bit microprocessor based Intelligent Addressable Fire Alarm Control panel with 2 loop with battery back up to 72 hours, expandable upto min. 14 loops w/o changing the cabinet. The control panel, batteries, battery charger etc, shall be Vds approved and as per EN-54 standard. The panel should be modular, decentralized, with 100% hot redundancy in cpu/master control unit, 100% hot redundancy in loop cards, relay and interface card by means of duplicated electronics means hardware redundancy with full functionality. The panel shall consisting with minimum 240 character LCD display. Panel should be able to record atleast 65000 events history. Each loop should be capable to have atleast 250 elements / devices out of which min. 200 nos. shall be detectors as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001417 | 1 | Each |
| 306 | 5.03 | Supply, Installation, Testing & Commissioning of Intelligent Addressable type multisensor detector with base, with 8 bit Microprocessor inbuilt, for use as heat (Fixed + Rate of Rise or individual ) or smoke or combined both with automatic electronic addressing, microprocessor type and must have integrated short circuit isolator (in case short circuit isolator is not inbuilt, the price of this item shall be inclusive of an independent short-circuit isolator along with each detector). The detector shall have IP 44 protection catagory & ambient temperature -20°C to + 60°C, the base shal have no electronics only dry contact terminals. The quoted item shall completely comply to the technical specification.Shall be Vds approved according to EN 54-5, 54-7, 54-17, 54-29 as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001418 | 40 | Each |
| 307 | 5.04 | Supplying installation testing and commissioning of Addressable Manual Pull Station, complete with addressable mini input module, back box and accessories & shall be VDS Approved, as per direction of Engineer-in-charge. Make:SCHRACK/HONEYWELL/GODREJ | BI01010001010000000000000515BI0100001419 | 8 | Each |
| 308 | 5.05 | Supplying installation testing and commissioning of Audio Visual Strobe for ceo office & CFS Control Room, complete with mounting box and accessories and module if require as per direction of Engineer-incharge | BI01010001010000000000000515BI0100001420 | 4 | Each |
| 309 | 5.06 | Supplying installation testing and commissioning of Response indicatorsand accessories and module if require as per direction of Engineer-incharge. | BI01010001010000000000000515BI0100001421 | 20 | Each |
| 310 | 5.07 | Supplying installation testing and commissioning of a pair of 1.5 sq.mm single core FRLS cable (2X1.5sq mm) to be laid within Existing MS conduit of suitable size to be erected above the wall or concealed, as the case may be, with all accessories & shall be VDS Approved, as per direction of Engineer-in-charge.make: polycab | BI01010001010000000000000515BI0100001422 | 450 | Mtr |
| 311 | 5.08 | Supply, delivery and laying of following sizes of 1.6 MM PVC .25mm diaConduit in surface/ in recess alongwith other accessories and 18 swg GI wire complete for Fire Alarm wiring including painting as required and as per direction of Engineer-in-charge | BI01010001010000000000000515BI0100001423 | 250 | Mtr. |
| 312 | 5.09 | Supply, delivery and laying of following 20 X 40 MM sizes of auto glow FLOM Board 2.5 mm thickness signages as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001424 | 4 | Each |
| 313 | 5.1 | ELECTRICAL PANEL SUPPRESSION SYSTEM Supply, fixing, testing and commissioning of Automatic linear pneumatic Tube Detection based Clean Agent System for Electrical Panel ( Panel Protection System), consisting of the following components:as required and as per direction of Engineer-in-charge.2 KG Clean Agent system complete with all necessary Clean Agent FK-5-1-12 / Novec 1230 (UL listed ) gas ,fitting ,support , and accessories, connected with CE & PI Mark DLP valve. Cylinder. With Helium Leak Tested to 10^-7 mbar l/sas required and as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001425 | 1 | Each |
| 314 | 5.11 | Supply, fixing, testing and commissioning of End of Line Adaptor | BI01010001010000000000000515BI0100001426 | 1 | Each |
| 315 | 5.12 | Supply, fixing, testing and commissioning of Pressure Switch (UL Listed) | BI01010001010000000000000515BI0100001427 | 2 | Each |
| 316 | 5.13 | Flexible Polymer Detection Tube with all necessary fittings &supports. (UL Listed) | BI01010001010000000000000515BI0100001428 | 50 | Mtr. |
| 317 | 5.14 | Supply, fixing, testing and commissioning OF Health Monitoring Cum Alarm Panel as required and as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001429 | 1 | Each |
| 318 | 5.15 | (a) Providing and fixing GFRC (Glass Fiber Reinforced Concrete) letter in the style \" Central Township, Kaliapani\" IN English and Odia script where each letter shall have the avg height of 700mm and width of 75mm to be fixed on the top face of the entrance gate by using anchor fasteners such as hilty/fischer at 7.50 m to 9.0 m including cost of all materials, T&P, Scafoldings, royalty, taxes etc. complete.\n(b) Providing and fixing GFRC (Glass Fiber Reinforced Concrete) letter in the style OMC logo proposinate to the dishplay copy of logo avialable iat OMC web site to be fixed in vertical wall in between two gates by using anchor fasteners such as hilty/fischer including cost of all materials, T&P, Scafoldings, royalty, taxes etc. complete.\n(c) Painting the logo as well as signage letters with exterior acrlyc base texture paint over approved primer of approved brand and shade over finished surface including cost of all materials, T&P, Scafoldings, royalty, taxes etc. complete as directed by EIC. | BI01010001010000000000000515BI0100001430 | 1 | Each |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender