Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #26772258

Replacement Of Aluminum Wiring With Copper Wiring In Som Lab Of Mechanical Engg .

Issued by Boards / Undertakings / PSU · Punjab Engineering College, Chandigarh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
09 Feb 2021
0 days left
EMD
4651
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Punjab Engineering College → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Replacement Of Aluminum Wiring With Copper Wiring In Som Lab Of Mechanical Engg .

BOQ

Name of Work: Replacement of aluminium wiring with copper wiring in SOM lab of Mechanical Engg. Deptt. at Punjab Engineering College, Sector-12, Chandigarh.
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11WIRINGBI01010001010000000000000515BI0100001112
22Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.BI01010001010000000000000515BI0100001113
334 X 6 sq. mm + 2 X 6 sq. mm earth wireBI01010001010000000000000515BI0100001114125Metre
44Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.BI01010001010000000000000515BI0100001115
55Group ABI01010001010000000000000515BI010000111637Point
66Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.BI01010001010000000000000515BI0100001117
772 x 1.5 sq. mmBI01010001010000000000000515BI010000111850Metre
883 x 2.5 sq. mm75Metre
993 x 4 sq. mm180Metre
1010Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
111125 mm40Metre
121240 mm11Metre
1313Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
1414Bell push1Each
1515Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
16165/6 A switch48Each
171715/16 A switch11Each
18183 pin 5/6 A socket outlet21Each
19196 pin 15/16 A socket outlet11Each
2020Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.10Each
2121Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.15Each
2222Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
23236 Module (200mmX75mm)21Each
242412 Module (200mmX150mm)6Each
2525Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.6Each
2626Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.11Each
2727Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.21Each
2828Supplying and fixing brass batten/ angle holder including connection etc. as required.2Each
2929Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.1Each
3030Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required.10Metre
3131Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).4Each
3232Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required.2Each
3333MCCB, MCB & DB'S
3434Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
3535100 A, 16 KA,TPMCCB4Each
3636Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
3737Single pole12Each
3838Triple pole and neutral2Each
3939EARTHING
4040Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.2Each
4141Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.16Metre
4242Supplying and fixing TP sheet steel enclosure mase od 16G sheet on surface/ recess switch for TPN MCCB of 100 Amp. The enclosure should be nicely painted from inner and outside.4each
4343Supply erection testing and commissioning of surface mounted 32 watt or more LED light fixtures 4'*1' lumens 2900 or more, colour 6000-6500K cool day light. The fitting shall be fixed on RCC ceiling with roll plugs and screws. Necessary connection with 3*1.5 sqmm copper wire from adjacent light point. Make Philipas model SM 270C LED 30S 6500 PSU WH or its equivalent of WIPRO,Havells make.11each
4444Supply erection testing and commissioning of surface mounted LED 1* 18/20 watt 4' long LED Box type fitting made of CRCA sheet. LED should be of Philips/Wipro/Jaguar/Havells make of polycarbonate material only. The job includes carriage, erection making connection with 3*1.5 sqmm copper wire from adjacent light point to the satisfaction of Engineer in charge complete with accessories and tube/lamp etc minimum 1800 lumens operating voltage 140V-270V AC coulor 6000-6500K electronic driver7each

AI Tender Summary

OUR REF NO 26772258
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 09-02-2021
Authority
Authority Name Pec University Of Technology
Work Description Replacement Of Aluminum Wiring With Copper Wiring In Som Lab Of Mechanical Engg .
Basic Detail
Tender No PEC/UE/JAN/2021/I
Bidding Type Tender
Location
City Punjab Engineering College
State Chandigarh
Key Dates
Publish Date 29 Jan 2021
Submission Date 09 Feb 2021
Open Date 09 Feb 2021
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 4651
Exemption Not Available
Document List
Tendernotice_1.pdf
BOQ_71898.xls
3ECEB1EE-82C4-4B3F-B5FB-BE8DB1A031CF.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 29, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 09, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 09, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

xls

BOQ_71898.xls

html

3ECEB1EE-82C4-4B3F-B5FB-BE8DB1A031CF.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender