| 1 | 1 | VALVE BALL NON FIRE SAFE-CSS | | | |
|---|
| 2 | 1.01 | BALL VALVE,SS, 150,0, API 608, FLGD,B16.5,RF, LO, SINGLE REDUCED PORT, BB, SHORT PATTERN, A182 F304 /A351 CF8, A182 F316 /A351 CF8M, STEM SS 316, PTFE, SEAL PTFE, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, VENDOR TO SUBMIT PRESSURE-TEMP., RATING CHART, DESIGN PRESSURE 10.5 KG/CM2(G), DESIGN TEMPERATURE 65 DEG.C | VKD370+50+-+-+-+-+- | 1 | Nos |
|---|
| 3 | 2 | VALVE BALL FIRE SAFE-CCS | | | |
|---|
| 4 | 2.01 | BALL VALVE,CS, 150,0, API 608, FLGD,B16.5,RF, LO, SINGLE REDUCED PORT, BB, FIRE SAFE, SHORT PATTERN, VALVE SHALL BE EQUIPPED WITH, LIMIT SWITCH., REFER ATTACHMENT-I FOR LIMIT, SWITCH SPECIFICATION., LIMIT SWITCH SHALL INDICATE, CLOSED POSITION OF VALVE., A105N / A216 Gr.WCB, A182 F316 /A351 CF8M, STEM SS 316, A182 F316 /A351 CF8M, SEAL GRAPHITE, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, VENDOR TO SUBMIT PRESSURE-TEMP., RATING CHART, DESIGN PRESSURE 10.5 KG/CM2(G), DESIGN TEMPERATURE 260 DEG.C, SHALL HAVE 120MM EXTENDED SPINDLE, (MEASURED FROM THE VALVE BONNET) TO ENSURE, THAT THE WRENCH CLEARS VALVE INSULATION., THE SPINDLE TO HAVE AN OUTER STATIONARY, TUBE WELDED TO THE VALVE BONNET AND HAVING, A WEATHER SEAL AT THE WRENCH END., THE STATIONARY TUBE ENABLES THE INSULATION, TO BE PROPERLY SEALED AROUND IT., INTERNAL CAVITY OVER PRESSURE, PROTECTION BY MEANS OF SELF RELIEVING S, ACCORDINGLY FLOW DIRECTION SHALL MARKED, ON THE | VKD140MHS+25+-+-+-+-+- | 1 | Nos |
|---|
| 5 | 2.02 | BALL VALVE,CS (H2 SER.), 600,0, API 608, FLGD,B16.5,RF, LO, FULL BORE, BB, FIRE SAFE, SHORT PATTERN, A105N / A216 Gr.WCB, A182 F316 /A351 CF8M, STEM SS 316, RTFE, SEAL GRAPHITE, A193 Gr.B7/A194Gr.2H, ADD. INFORMATION, VENDOR TO SUBMIT PRESSURE-TEMP., RATING CHART, DESIGN PRESSURE 33 KG/CM2(G), DESIGN TEMPERATURE 146 DEG.C, VALVE SHALL BE SUITABLE FOR FULL VACUUM, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, SHALL HAVE 120MM EXTENDED SPINDLE, (MEASURED FROM THE VALVE BONNET) TO ENSURE, THAT THE WRENCH CLEARS VALVE INSULATION., THE SPINDLE TO HAVE AN OUTER STATIONARY, TUBE WELDED TO THE VALVE BONNET AND HAVING, A WEATHER SEAL AT THE WRENCH END., THE STATIONARY TUBE ENABLES THE INSULATION, TO BE PROPERLY SEALED AROUND IT., INTERNAL CAVITY OVER PRESSURE, PROTECTION BY MEANS OF SELF RELIEVING S, ACCORDINGLY FLOW DIRECTION SHALL MARKED, ON THE | VKD143FH+40+-+-+-+-+- | 1 | Nos |
|---|
| 6 | 2.03 | BALL VALVE,EXT. BONNET,LTCS, 300,0, API 608, FLGD,B16.5,RF, LO, SINGLE REDUCED PORT, BB, FIRE SAFE, SHORT PATTERN, EXT. BONNET ACC. TO BS 6364, (NON-COLD BOX APPLICATION), A352 Gr.LCB, A182 F316 /A351 CF8M, STEM SS 316, RTFE, SEAL GRAPHITE, A320Gr.L7/A194Gr.4, ADD. INFORMATION, VENDOR TO SUBMIT PRESSURE-TEMP., RATING CHART, DESIGN PRESSURE 26.4 KG/CM2(G), DESIGN TEMPERATURE 65 DEG.C, SHALL HAVE 200MM EXTENDED SPINDLE, (MEASURED FROM THE VALVE BONNET) TO ENSURE, THAT THE WRENCH CLEARS VALVE INSULATION., THE SPINDLE TO HAVE AN OUTER STATIONARY, TUBE WELDED TO THE VALVE BONNET AND HAVING, A WEATHER SEAL AT THE WRENCH END., THE STATIONARY TUBE ENABLES THE INSULATION, TO BE PROPERLY SEALED AROUND IT., INTERNAL CAVITY OVER PRESSURE, PROTECTION BY MEANS OF SELF RELIEVING S, ACCORDINGLY FLOW DIRECTION SHALL MARKED, ON THE | VKD291E+25+-+-+-+-+- | 1 | Nos |
|---|
| 7 | 2.04 | BALL VALVE,EXT. BONNET,LTCS, 300,0, API 608, FLGD,B16.5,RF, LO, SINGLE REDUCED PORT, BB, FIRE SAFE, SHORT PATTERN, WITH LOCKING ARRANGEMENT, EXT. BONNET ACC. TO BS 6364, (NON-COLD BOX APPLICATION), A352 Gr.LCB, A182 F316 /A351 CF8M, STEM SS 316, RTFE, SEAL GRAPHITE, A320Gr.L7/A194Gr.4, ADD. INFORMATION, VENDOR TO SUBMIT PRESSURE-TEMP., RATING CHART, DESIGN PRESSURE 26.4 KG/CM2(G), DESIGN TEMPERATURE 65 DEG.C, SHALL HAVE 200MM EXTENDED SPINDLE, (MEASURED FROM THE VALVE BONNET) TO ENSURE, THAT THE WRENCH CLEARS VALVE INSULATION., THE SPINDLE TO HAVE AN OUTER STATIONARY, TUBE WELDED TO THE VALVE BONNET AND HAVING, A WEATHER SEAL AT THE WRENCH END., THE STATIONARY TUBE ENABLES THE INSULATION, TO BE PROPERLY SEALED AROUND IT., INTERNAL CAVITY OVER PRESSURE, PROTECTION BY MEANS OF SELF RELIEVING S, ACCORDINGLY FLOW DIRECTION SHALL MARKED, ON THE | VKD291EL+50+-+-+-+-+- | 1 | Nos |
|---|