| 1 | 0 | SCHEDULE 'A' | BI01010001010000000000000515BI0100001112 | | |
|---|
| 2 | 1 | Excavation over areas, n.exc. 1.5m in depth for foundation etc. and getting out in soft/disintegrated rock. | | 675 | Cum |
|---|
| 3 | 2 | Excavation over areas. n.exc 1.5 m deep and, getting out in soft/loose soil all as spd. | | 935 | CUM |
|---|
| 4 | 3 | Excavation for laying of cable not exc. 1.5 mtr wide and not exc 1.5 mtr. In depth and getting out in Soft/loose soil. | | 180 | Cum |
|---|
| 5 | 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm as in soft/disintegrated rock. | | 57 | Cum |
|---|
| 6 | 5 | Returning, Filling including spreading, leveling watering & well ramming in laying not exc.25 cm in Soft/loose soil. | | 177.63 | Cum |
|---|
| 7 | 6 | Removing excavated rock exc.500 m and n.exc 1.50 Km depositing where directed at a level n exc 1.5 m above the starting point. | | 618 | CUM |
|---|
| 8 | 7 | Removing excavated soil exc.500 m and n.exc 1.50 Km depositing where directed at a level n exc 1.5 m above the starting point. | | 937.37 | CUM |
|---|
| 9 | 8 | M&L for sand filling under floors or pavings,including spread, levelled watering complete all as specified and as directed . | | 70 | CUM |
|---|
| 10 | 9 | M&L moorum/red bajri filling in floors or pavings, laid in layers n exc 15cm thick, spread, levelled and rammed including watering complete all as specified and as directed by Engr-in-charge | | 20 | Cum |
|---|
| 11 | 10 | M&L for broken stone or boulders Hardcore of gauge exc 63 mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface all as specified. | | 8 | Cum |
|---|
| 12 | 11 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation and mass concrete complete all as specified and directed. | | 8.3 | Cum |
|---|
| 13 | 12 | M&L for plain cement concrete 1:2:4 (type B-1) using 20mm graded trap stone aggregates, as in coping, etc. including necessary use and waste of formwork complete all as specified and as directed. | | 0.5 | Cum |
|---|
| 14 | 13 | M& L Precast cement concrete type C1, 1: 3 : 6 (20 mm graded aggregate) block masonary with solid blocks ,exc,10 cm in width and setting in CM 1:6 complete all as specified. | | 25 | Cum |
|---|
| 15 | 14 | M&L Reinforced cement concrete M-30 (20 mm graded aggregate) in foundation, footing, foundation beams, plinth beams, base of columns complete all as specified and as directed. | | 19.5 | Cum |
|---|
| 16 | 15 | M&L Reinforced cement concrete M-30 (20 mm graded aggregate) Columns, pillars, piers, posts and struts . Complete all as specified and as directed. | | 10.5 | Cum |
|---|
| 17 | 16 | M&L Reinforced cement concrete M-30 (20 mm graded aggregate) in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed. | | 10.5 | Cum |
|---|
| 18 | 17 | M&L Reinforced cement concrete M-30 (20 mm graded aggregate) in slab supported on walls, complete all as specified and as directed. | | 16.5 | Cum |
|---|
| 19 | 18 | M&L for RCC M-30 (using 20mm aggregate) for chajjas, complete all as specified and as directed | | 0.6 | Cum |
|---|
| 20 | 19 | Supply only water proofing compound (integral) all as specified & directed. | | 30 | Kgs |
|---|
| 21 | 20 | M&L for Formwork to flat sides with fair finish surface of concrete foundations, footings, bases of columns, raft and raft beams sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter | | 65 | Sqm |
|---|
| 22 | 21 | M&L for Formwork to sides of pillars,posts, struts, piers, columns and stanchions with rough finish surface | | 102 | Sqm |
|---|
| 23 | 22 | Form work to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work not exceeding 200 mm thick in sloping. | | 105 | Sqm |
|---|
| 24 | 23 | Form work to sides and soffits of floor or roof beams, beam haunching,lintel etc. | | 105 | Sqm |
|---|
| 25 | 24 | Formwork to chullah hoods, chajjas, troughs and similar items including edges as in rough finished surfaces of concrete complete all as specified. | | 3 | Sqm |
|---|
| 26 | 25 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips. | | 2100 | Kg |
|---|
| 27 | 26 | -ditto- all as per item No. above, but 6mm dia to 8mm dia. complete all as specified and as directed. | | 900 | Kg |
|---|
| 28 | 27 | -ditto- all as per item No. above, but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders | | 650 | Kg |
|---|
| 29 | 28 | S & F Steel rolling shutters, with out ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indi cated, complete: push pull or manual type , thickness of laths 1.25 mm complete all as specified and as directed. | | 12.6 | Sqm |
|---|
| 30 | 29 | M&L 75mm thick Cement concrete 1:3:6, type C1 (using 20 mm graded stone aggregate) as in plinth protection finished even and smooth without using extra cement. | | 40 | Sqm |
|---|
| 31 | 30 | M&L for PCC 1:5:10 type E-2 using 40 mm graded stone aggregate 75 mm thick as in sub base | | 72 | Sqm |
|---|
| 32 | 31 | M&L for PCC (1:2:4) type B1 using 20 mm graded aggregate as in floor of average 25mm thick. | | 72 | Sqm |
|---|
| 33 | 32 | M&L Machine cut kota stone slab flooring 20-25mm thick over 15 mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified. | | 72 | Sqm |
|---|
| 34 | 33 | -ditto- all as per item ser no here-in-before but in skirting/dado or verticle surfaces with back coat of screed bed or bedding layer of 10 mm thick 1:4 complete all as specified. | | 4 | Sqm |
|---|
| 35 | 34 | M&L for rendering 15mm thick, cement plaster, in cement mortar (1:4) mixed with integral water proofing compound as per manufactures instruction, on roof slab surfaces finished even and smooth without using extra cement,complete all as specified and directed. \nNote:- Water proofing compound shall be measured and paid separately) | | 95 | Sqm |
|---|
| 36 | 35 | M&L for rendering 10 mm thick on fair face of brick work or concrete surfaces in CM 1:6 finished even and smooth wiithout using extra cement. | | 105 | Sqm |
|---|
| 37 | 36 | M&L for rendering 15mm thick, cement plaster, in cement mortar (1:4) mixed with integral water proofing compound as per manufactures instruction, on other than fair faces of brick walls or concrete surfaces finished even and smooth without using extra cement in any height, complete all as specified and directed. Note:- Water proofing compound shall be measured and paid separately) | | 120 | Sqm |
|---|
| 38 | 37 | M&L for rendering 5mm thick cement plaster in cement mortar 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement on ceiling in any height complete all as specified and directed. | | 72 | Sqm |
|---|
| 39 | 38 | M&L preparation of new plastered or unplastered surfaces and applying two coats of oil bound distemper on wall over a coat of alkali resistant primer complete all as specified and darected. | | 105 | Sqm |
|---|
| 40 | 39 | M&L preparation of surfaces and applying two coat of white wash on new plastered surfaces of ceiling complete all as specified and as directed. | | 72 | Sqm |
|---|
| 41 | 40 | M&L for providing APP based membrane course roof treatment in layers with following provisions:- \n(i) Applying one coat of bitumen's primer polymerized primer oil based coat, evenly @ 0.3KG/Sqm as priming coat to the prepared surfaces, till the surfaces is properly impregnated and the solvent oil in the base primer shall be allowed to evaporated completely.\n(ii) Applying APP based pre-fabricated with non woven polyester reinforced membrane stabilized with fibre glass strands and top with grey mineral slates 3mm thick and weight not less than 3.50 Kg/Sqm by torch application method.\n(iii) Applying a coat of solar reflective bituminous aluminium paint @ 0.10Kg/Sqm over mineral surface.\n | | 95 | Sqm |
|---|
| 42 | 41 | S&F powder coated aluminium anodised three track sliding window shutter and frame including jointing clit for fixing frame/chowkhat of window as per JINDAL section code (frame 20831), shutter (20846) including glazing with 5mm thick tinted glass & Aluminium wire mesh necessary fittings, rubber packing, suitable handles, rollers for shutters etc complete all as specified and as directed. | | 9 | Sqm |
|---|
| 43 | 42 | S&F powder coated aluminium grill with suitable aluminium anodised frame F/H section manufactured by M/s DECO GRILL as per design No DG-104, 6 mm thick complete all as specified and as directed. | | 9 | Sqm |
|---|
| 44 | 43 | M&L for Aplying two coat of anticrosive paint on steel surfaces of any description, over 10cm in width or girth,not otherwise described | | 25 | Sqm |
|---|
| 45 | 44 | M&L for preparation of new plastered surfaces of wall and applying two coats of weather proof acrylic exterior emulsion paint over a coat of acrylic primer all as per the manufacturers instructions, complete all as specified and directed by Engr-in-charge. | | 120 | Sqm |
|---|
| 46 | 45 | M&L for approved fertile earth filling in floors or pavings, suitable for plantation incl watering maneovering of earth. | | 1455 | CUM |
|---|
| 47 | 46 | Supplying and Planting( dibbling) of high quality natural green lawn grass ( selection-1 ) of approved quality at uniform spacing including levelling the land perfect , making the leveled soil free from debris, weeds, seeds, mixing it with base fertilizer and watering once complete all as specified and as directed by Engr-in -charge. | | 2500 | SQM |
|---|
| 48 | 47 | Supplying and Planting of avenue trees of approved species as per direction incl excavation of pits of required size and depth in all types of soil and back fill approved back cotton soil after soil treatment with chemical and fertilizer, incorporating manure of approved quality in the proportion of 1:3 (One part of manure & 3 part of soil) manure 200 gm per plant and using pesticides of approved quality etc and removing surplus soil to a distance n.exc 1.50 Km and depositing where directed.\n(a) Ficus Plant ht not less than 900 mm | | 180 | Each |
|---|
| 49 | 48 | (b) Casurina Plant ht not less than 900 mm | | 180 | Each |
|---|
| 50 | 49 | (c) Justucia Plant ht not less than 900 mm | | 2000 | Each |
|---|
| 51 | 50 | (d) Fox tail palm Plant ht not less than 1800 mm | | 67 | Each |
|---|
| 52 | 51 | (e) Flower Plant like ixora, Jarropha etc | | 500 | Each |
|---|
| 53 | 52 | (f) Herbal Plant | | 63 | Each |
|---|
| 54 | 53 | Maintenance of plants and grass(As per item No.7 & 8 above) for a period of 24 months incl removing of weed, watering, sparying of pesticide, adding manure etc all as specified and as directed. | | 24 | month |
|---|
| 55 | 54 | Supply, laying and jointing GI tubes 80 mm bore medium grade in any lengths with screwed and socket joints, together with all galvanised steel fitting such as sockets, elbows, bends, tees, reducers, unions, cap plugs, nipple, short pieces etc fixed complete by means of and including clips, wall hook etc or laid in trenches all as specified and directed. | | 240 | RM |
|---|
| 56 | 55 | Supply and laying of CPVC pipes of size 50 mm dia (outer dia) SDR-13.5& plain SDR 11 fittings fittings like brass elbow brass tee, male threaded brass adapter, female threaded brass adaptor unions, flange and tank adapter incl fixing solvents all as per manufacturers recommenations and complete all as specified and directed. | | 280 | RM |
|---|
| 57 | 56 | Supply and laying of CPVC pipes of size 32 mm dia (outer dia) SDR-13.5 & plain SDR 11 fittings fittings like brass elbow brass tee, male threaded brass adapter, female threaded brass adaptor unions, flange and tank adapter incl fixing solvents all as per manufacturers recommenations and complete all as specified and directed. | | 230 | RM |
|---|
| 58 | 57 | Supply and laying of CPVC pipes of size 25 mm dia (outer dia) SDR-13.5 & plain SDR 11 fittings fittings like brass elbow brass tee, male threaded brass adapter, female threaded brass adaptor unions, flange and tank adapter incl fixing solvents all as per manufacturers recommenations and complete all as specified and directed. | | 250 | RM |
|---|
| 59 | 58 | S & F CPVC Ball Valve of Size 25 mm dia and connected to two ends externally for CPVC pipe or for unions and fixed complete all as specified and as directed. | | 18 | Each |
|---|
| 60 | 59 | S & F CPVC Ball Valve of Size 32 mm dia and connected to two ends externally for CPVC pipe or for unions and fixed complete all as specified and as directed. | | 18 | Each |
|---|
| 61 | 60 | S & F CPVC Ball Valve of Size 50 mm dia and connected to two ends externally for CPVC pipe or for unions and fixed complete all as specified and as directed. | | 8 | Each |
|---|
| 62 | 61 | M&L for point wiring for one light/fan controled by one switch with 1100 volt grade 1.5 sqmm copper multi stranderd conductor PVC insulated cable in and including Concealed PVC Conduit with all accessories and duly earhted with 1.5 sqmm copper conductor PVC insulated unsheathed earth continuity wire connected comon earth dolly terminated in and including PVC moulded terminal boxes with cover complete.all as specified and directed by EIC. | | 6 | Point |
|---|
| 63 | 62 | Ditto all as per item no. 1 above, but for 3 pin 5 amps switch socket outlet on Same board complete. | | 1 | Point |
|---|
| 64 | 63 | Ditto all as per item no. 1 above, but for 3 pin 5 amps switch socket outlet on Independent board complete. | | 2 | Point |
|---|
| 65 | 64 | Ditto all as per item no.1 above, but for 3 pin 15 amps switch socket outlet with 4 sqmm multi stranderd copper conductor cable on independent board complete. | | 2 | Point |
|---|
| 66 | 65 | Supply and fix ceiling rose, surface bakelite three terminals | | 6 | Each |
|---|
| 67 | 66 | S & F switch piano flush button single pole one way 5 amps complete. | | 6 | Point |
|---|
| 68 | 67 | S & F switch socket combination multipurpose 2 in 1, 5amps flush type complete all as specified and directed by EIC. | | 3 | Each |
|---|
| 69 | 68 | S & F switch socket combination multipurpose 2 in 1, 3 Pin 5 and 15 Amps flush type universal complete. | | 2 | Each |
|---|
| 70 | 69 | Supply and fixing of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd. complete all as specified. | | 1 | Each |
|---|
| 71 | 70 | M&L for sub main wiring with two single core 4 Sqmm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit with all accessories, PVC insulated 2.5 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. \nNote : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit. | | 6 | RM |
|---|
| 72 | 71 | S & F MCB DB 8 way SPN, double door, vertical type, IP - 53 with 200 Amps rated bus bar, Concealed and connecting up complete all as specified. | | 1 | Each |
|---|
| 73 | 72 | M&L for earthing using GI earthing strip 32 x 6 mm complete with galvanised steel earth plate electode 600mmx600mmx6mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level connection to and including GI strip of size 32x6mm to the extend 7.5 mtr as earth lead by means of GI bolts, Nuts etc. with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I including water arrangement with GI Pipe 20 MM dia (medium Grade), earth lead protection pipe 50mm madium grade with bends, elbow etc. from earth plate to test point, excavation and earth work returning, filling, ramming and removing of soil to distance not exc 50mtr, make good to match with existing surface making PCC pit (Earth chamber) having internal size 30cm x 30cm x 30cm and outer size 60cm x 60cm x 60cm with RCC reinforced cover 50mm thick and testing on completion including making test point on wall as per SSR specification all as specified and directed. | | 2 | Each |
|---|
| 74 | 73 | S & F wall mounted LED Tube light fitting 1x20W LED Tube T8, 4 feet including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting in position at site on 02 Nos new round/sqare blocks complete all as specified and directed. \nMake Wipro - CAT PT No- WIO831208G1or equivalent to Bajaj/Havells | | 4 | Each |
|---|
| 75 | 74 | Supply & fix 05 star rated ceiling fan 1200mm sweep and connecting up to and including provision of 23/0.0076 flexible three core PVC insulated copper conductor cable from ceiling rose to fan etc complete all as specified and as directed.make: Orient(Crown), CG(HS Plus), Havells(ES-50) | | 1 | Each |
|---|
| 76 | 75 | Supply and fix Exhaust fan 300mm sweep 240 V AC metal body fixed as per maufacturers instruction, connecting with and including 2 core x 0.5 Sqmm copper coduct PVC insulated and PVC sheathed three core cable complete or equivalent. | | 1 | Each |
|---|
| 77 | 76 | Supply and fixing of MCB SP, 240 volt, 6 to 32 Amps complete all as specified. | | 6 | Each |
|---|
| 78 | 77 | Supply and fixing of MCB SPN, 240 volt, 40 Amps complete all as specified. | | 1 | Each |
|---|
| 79 | 78 | Supply and fixing gun metal globe or gate valve of 80 mm dia, with wheel head screwed both ends for GI pipe and fixed, ISI marked including providing required fitting and one union with each valve of following dia all as specified and directed. | | 6 | Each |
|---|
| 80 | 79 | S & F disc filter of Size 80 mm dia and connected to two ends externally for GI pipe or for unions and fixed complete all as specified and as directed. | | 2 | Each |
|---|
| 81 | 80 | Supply, testing and commissioning of Monobloc pump set of discharge capacity 2000 LPM at 18 mtr head of 5 HP (3.7 KW), 3000 rpm, 3 phase 415 volts, 50 Hz, mounted on MS chanel/common base plate and fixed with suitable bolts, grouted in PCC foundation, 30 CM above floor level including PVC insulated single core unsheathed copper conductor of 4 sqmm 3 core size drawn in PVC conduit for connection from starter to motor terminal, including the following accessories. Make: - Kirloskar cat No KDS 550++, code D12010500510 /Crompton. | | 2 | Each |
|---|
| 82 | 81 | Supply & fix LT panel Board cubical Indoor type wall mounted compact metalised 415 Volts AC 50 Hz, fabricated of CRCA sheet 1.6 mm thick, totally enclosed, non draw out type, dust and vermin proof, compartmentalized design, epoxy coated (shade ral 7032) after 7 tank pretreatment process, IP 52 degree of protection, size not less then 1000 mm x750mm x 400 mm (minimum), angle iron frame for floor mounted complete including copper bus bar 200 Amps 4 strip mounted on porcelain insulated & enclosed in chamber & connection from incoming and outgoing with openable shutter both sides compressing of following :- \nMake: BCH/L&T/C&S/SCHNEIDER/ABHUNIK/ADVANCE\n(a) Incoming MCCB 63 Amps 4 pole with adjustable thermal and Magnetic setting having breaking capacity 25 KA - 01 Nos\n(b) Outgoing Star Delta starter 5 HP (MK 1 DOL Starter DSN 8536 L&T Cat No SS96210POVO - 02 Nos\n(c) Outgoing MCCB 32 Amps, four pole with adjustable thermal and Magnetic setting having breaking capacity 30 KA - 02 Nos \n(d ) Digital Voltmeter 0-500 V 96x96xm …. 01 No\n(e) Digital Ammeter 0 - 500 A 96x96m …. 01 No\n(f) Indicating lamps set RYB …. 01 set\n(g) Selector Switch …. 01 Set\n(h) Vary depth type rotary handles for incoming/outgoing MCCBs\n\n\n\n\n | | 1 | Each |
|---|
| 83 | 82 | Supplying, Fixing, Testing & Commissioning of Automated Landscape Irrigation System, System consists of Pop up Sprinkler with complete accessories, manual filter, control valves with automation components, having bore of 25 mm dia complete all as specified and as directed. | | 30 | Each |
|---|
| 84 | 83 | Supply and fixing flat copper cable 1100 volt grade of size 6 sqmm, 3 core multi stranded complete all as specified and directed. Make :- Polycab/Havells/Finolex | | 30 | RM |
|---|
| 85 | 84 | M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil | | 30 | RM |
|---|
| 86 | 85 | M & L Construction of valve pit chamber of follwong sizes with brick massonary, one brick thick wall in cement mortor (1:4) on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded aggregate) as in fdn, 15 mm thick cement & plaster rendering internally all arround over brick wk & externally upto 15cm below normal GL with 10 SWG thick MS sheet cover incld 40 x 40 x 6mm MS angle frame fixed locking arrangement and painting with one coat of red oxide and two coats of black Bituminous paints of size 1000 mm x 1000 mm x 900mm. | | 2 | Each Job |
|---|