Improvement Of Water Supply With Laying 200 Mm Dia Di Pipe And 150 Mm Dia Hdpe Pipe For Inter Connection 400 Mm Dia Pipe At B Road , C Road Ward No - 7
Tender Value
16.72 Lakhs
Estimated cost
Bid Submission
12 Feb 2021
0 days left
EMD
33452
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Under HMC area → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Improvement Of Water Supply With Laying 200 Mm Dia Di Pipe And 150 Mm Dia Hdpe Pipe For Inter Connection 400 Mm Dia Pipe At B Road , C Road Ward No - 7
BOQ
| Name of Work: Improvement of water Supply with laying 200 mm dia Di pipe and 150 mm dia HDPE pipe for inter connection 400 mm dia pipe at B Road, C Road Ward no - 7 | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Picking up & remove old bituminous layer ................... Where thickness of layer is. KMDA,(W.S)2012, P-61, It- 1.3 a,b,c ii) 50mm to 100mm | 325 | M2 | |
| 2 | 2 | Dismantling all types of plain cement concrete……..directed. Up to 150 mm thick. Ref: P.W.D (Bldg) Sch. -2017, page -10 It- 2(a) | 4 | M3 | |
| 3 | 3 | Earth work in excavation in trenches .................of the E.I.C a) Upto 1.5 M below G.L KMDA,(W.S)2012, P-61, It- 1.1.a | 455 | M3 | |
| 4 | 4 | Hire and labour charges 75 mm dia bamboo railing …………timber. Railing with 3 rows. Ref: P.W.D (Bldg) w.e.f- 1.11.2017, page -271, It- 4(ii) | 80 | M | |
| 5 | 5 | Hire and labour charges for shoring work …………….of the E.I.C KMDA,(W.S)2012, P-61, It- 1.5a, (1&2) (a) Depth up to 1.5M | 50 | M2 | |
| 6 | 6 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm............. complete. Ref: P.W.D (Bldg) Sch. -2017, page -2, It- 4(a) | 16.31 | M3 | |
| 7 | 7 | Lowering and type D.I pipes………….of the E.I.C. KMDA(WS)2012, P-63, IT-2.2.b,c&d (c) 200 mm dia.& 250mm dia | 150 | M | |
| 8 | 8 | Rubber gasket joints to D.I pipes……of the E.I.C. KMDA(WS)2012, P-66, IT-2.5b,c&d,e,f (c) 200 mm dia. | 30 | Each | |
| 9 | 9 | Lead jointing to C.I pipes……….of the E.I.C KMDA(WS)2012, P-64, IT-2.3.b,d &e,f,g (c) 200 mm dia. | 4 | Each | |
| 10 | 10 | Flange joints to D.I pipes and specials………….of the E.I.C.KMDA(WS)2012’, P-67, IT-2.6, b,d &e,f,g (b) 150 mm dia. | 4 | Each | |
| 11 | 11 | Flange joints to D.I pipes and specials………….of the E.I.C.KMDA(WS)2012’, P-67, IT-2.6, b,d &e,f,g (c) 200 mm dia. | 2 | Each | |
| 12 | 12 | Cutting C.I/D.I pipes for fittings with pipes……….of the E.I.C. KMDA(WS)2012’, P-68, IT-2.7, b,c &d,e,f (b) 150 mm dia. | 1 | Each | |
| 13 | 13 | Cutting C.I/D.I pipes for fittings with pipes……….of the E.I.C. KMDA(WS)2012’, P-68, IT-2.7, b,c &d,e,f (c) 200 mm dia. | 8 | Each | |
| 14 | 14 | Chamfering the spigot end to C.I/D.I pipes of the E.I.C. KMDA(WS)2012’, P-69, IT-2.8, c,d,e,f (b) 200 mm dia. | 30 | Each | |
| 15 | 15 | Lowering fitting and fixing all types of valves………of the E.I.C. KMDA(WS)2012’, P-81, IT-5.2, b,d,e,f.g (b) 150 mm dia. | 2 | Each | |
| 16 | 16 | Lowering fitting and fixing all types of valves………of the E.I.C. KMDA(WS)2012’, P-81, IT-5.2, b,d,e,f.g (c) 200 mm dia. | 1 | Each | |
| 17 | 17 | Shifting house connection or stand post …………of the E.I.C............................. KMDA(WS)2012’, P-85, IT-6.7 | 52 | Each | |
| 18 | 18 | C.I. Sluice Valve cast iron double flanged …………..I.S 1538:1993 KMDA(WS)2012’, P-99, IT-10.7, ii,iv,v,vi,vii(b) 150 mm dia. | 2 | Each | |
| 19 | 19 | C.I. Sluice Valve cast iron double flanged …………..I.S 1538:1993 KMDA(WS)2012’, P-99, IT-10.7, ii,iv,v,vi,vii(c) 200 mm dia. | 1 | Each | |
| 20 | 20 | Dewatering by pumps .........of the E.I.C. KMDA(WS)2012’, P-119, IT-13.1 | 800 | HP/HR | |
| 21 | 21 | Centrifugally cast (Spun) D.I pipe…………….coating class K9 KMDA(WS)2012’, P-94, 95 IT-10.4 A,c,d,e & B, a,ba) 200 mm dia. | 150 | Mtr. | |
| 22 | 22 | Providing lighting arrangements…………….etc complete. Rate approved by HMC | 2 | Night | |
| 23 | 23 | Drilled & taping C.I main up to 15mm PWD(S&P) w.e.f 1.11.17 P-27 It-18(i) | 4 | Set | |
| 24 | 24 | Supplying, fitting & fixing G.I pipe of TATA make underground…………..in all respect. PWD(S&P) w.e.f 1.11.17 P-2 It-3(ii) (a) 15 mm dia(M.Q). | 2 | M | |
| 25 | 25 | Hydraulically testing of C.I/D.I pipes………….of the E.I.C. KMDA(WS)2012’, P-88, IT-8.1b,c,d,e,f (b) 150 mm dia. | 600 | M | |
| 26 | 26 | Hydraulically testing of C.I/D.I pipes………….of the E.I.C. KMDA(WS)2012’, P-88, IT-8.1b,c,d,e,f (c) 200 mm dia. | 150 | M | |
| 27 | 27 | Disinfection of water main by filling with water ……………….of the E.I.C. KMDA(WS)2012’, P-90, IT-9.1 b,c,d,e,f (b) 150 mm dia. | 600 | M | |
| 28 | 28 | Disinfection of water main by filling with water ……………….of the E.I.C. KMDA(WS)2012’, P-90, IT-9.1 b,c,d,e,f (c) 200 mm dia. | 150 | M | |
| 29 | 29 | Supplying including cost of installation of C.I Mechanical compression ………………C.I/D.I pipes. [Ref:-K.M.D.A (ws)2012,Page-123,It-13.25]b,d,e,f,g (e) 150 mm dia. | 4 | EACH | |
| 30 | 30 | Supplying including cost of installation of C.I Mechanical compression ………………C.I/D.I pipes. [Ref:-K.M.D.A (ws)2012,Page-123,It-13.25]b,d,e,f,g (f) 200 mm dia. | 2 | EACH | |
| 31 | 31 | All types of C.I specials ………1538 to 1993. KMDA(WS)2012’, P-93, IT-10.3 a&b (a) Socket and Spigot ended. 92 80 mm to 300 mm | 275 | Kg. | |
| 32 | 32 | Earth Work in filling in foundation trenches…………from excavation KMDA(WS)2012’, P-61, IT-1.2 | 487.5 | M3 | |
| 33 | 33 | Removal of rubbish/Earth……….of the E.I.C. K.M.A.D (WS)2012 Sch. -2014, page -118, It- 12.8 | 325 | M3 | |
| 34 | 34 | Supply H.D.P.E pipe confirming to I.S-4984/1985.P.E-100 Rate accepted by H.M.C(a) 160 mm dia. | 600 | M | |
| 35 | 35 | Lowering and jointing labour charges for laying and jointing of 4984.P.E-100 Rate accepted by H.M.C (a)160 mm dia. | 600 | M | |
| 36 | 36 | Supply H.D.P.E pipe fittings………….P.E-100 Rate accepted by H.M.C (a) 160 mm dia bend. | 2 | Each | |
| 37 | 37 | Supply H.D.P.E pipe fittings………….P.E-100 Rate accepted by H.M.C (b) 160 mm dia pipe end | 30 | Each | |
| 38 | 38 | Supply H.D.P.E pipe fittings………….P.E-100 Rate accepted by H.M.C (c) 160 mm dia equal tee | 2 | Each | |
| 39 | 39 | Supply H.D.P.E pipe fittings………….P.E-100 Rate accepted by H.M.C (d) 160 mm dia sand with flange | 30 | Each | |
| 40 | 40 | Single brick soling………..sand Ref: P.W.D (Bldg) Sch. -2017, page -14, It- 1 | 390 | M2 | |
| 41 | 41 | Repair of Air valve supply Ebonite and rubber bell gasket, Nuts and bolts with washers and labour all complete. C.M.D.A (WS) 2012’,P-120, It-13.11(b),(c),(d) (a) 100 mm dia. | 2 | Each | |
| 42 | 42 | GST 12% | 1 | LS | |
| 43 | 43 | Labour wellfare Cess 1% | 1 | LS |
AI Tender Summary
Tender Timeline
Jan 28, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 12, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 15, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender