Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #26747269

Kiifb Project ( 2019-20 ) Infrastructure Development Of School , Vengara Lac - Construction Of Building For Ghs Kolappuram - Ar Nagar

Issued by Boards / Undertakings / PSU · Kolappuram, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
05 Feb 2021
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
2800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolappuram → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Kiifb Project ( 2019-20 ) Infrastructure Development Of School , Vengara Lac - Construction Of Building For Ghs Kolappuram - Ar Nagar

BOQ

Work Name:KIIFB Project (2019-20) Infrastructure Development of School , Vengara LAC - Construction of Building for GHS Kolappuram - AR Nagar
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Appendix-ABI01010001010000000000000515BI0100001113
21.0012.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soilBI01010001010000000000000515BI0100001114114cum
31.0022.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soilBI01010001010000000000000515BI0100001115198.948cum
41.0032.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.BI01010001010000000000000515BI010000111649.369cum
51.0044.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)BI01010001010000000000000515BI010000111732.751cum
61.0055.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concreteBI01010001010000000000000515BI0100001118135.36sqm
71.0065.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantileversBI01010001010000000000000515BI0100001119650.967sqm
81.0075.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and StrutsBI01010001010000000000000515BI0100001120355.2sqm
91.0085.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)BI01010001010000000000000515BI01000011214.68sqm
101.0095.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edgesBI01010001010000000000000515BI0100001122106.32sqm
111.015.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platformBI01010001010000000000000515BI0100001123533.22sqm
121.0115.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI010000112429.304cum
131.0125.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal sizeBI01010001010000000000000515BI010000112556.856cum
141.0135.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).BI01010001010000000000000515BI0100001126129.377cum
151.0145.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or moreBI01010001010000000000000515BI010000112721341.6kg
161.01560.7.1 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at siteBI01010001010000000000000515BI010000112819.88cum
171.01650.6.7.2 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.BI01010001010000000000000515BI0100001129159.411cum
181.01750.9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack woodBI01010001010000000000000515BI01000011302.81cum
191.01814.29 : Providing and fixing M.S. round or squre bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows.BI01010001010000000000000515BI0100001131560.7kg
201.01950.9.3.1 : Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack woodBI01010001010000000000000515BI010000113224.78sqm
211.0250.9.4.1 : Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack woodBI01010001010000000000000515BI010000113324.78sqm
221.02150.9.6.1 : Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood / jack wood 30 mm thick shuttersBI01010001010000000000000515BI010000113464.155sqm
231.02213.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)BI01010001010000000000000515BI0100001135860.778sqm
241.02313.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)BI01010001010000000000000515BI01000011361832.08sqm
251.02413.9.1 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plasterBI01010001010000000000000515BI0100001137340.06sqm
261.0255.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.BI01010001010000000000000515BI0100001138175.48metre
271.02610.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)BI01010001010000000000000515BI0100001139103.7kg
281.02713.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primerBI01010001010000000000000515BI01000011402595.05sqm
291.02813.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new workBI01010001010000000000000515BI01000011412699.33sqm
301.02913.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new workBI01010001010000000000000515BI0100001142216.062sqm
311.0313.50.1 : Applying priming coat:With ready mixed pink or Grey primer of approved and manufacture on wood work (hard and soft wood)BI01010001010000000000000515BI0100001143190.128sqm
321.03111.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.BI01010001010000000000000515BI0100001144584.415sqm
331.03211.19.4 : Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand):Ordinary cement without any pigmentBI01010001010000000000000515BI01000011458.88sqm
341.03310.6.3 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x0.90 mm M.S. laths with 0.90 mm thick to coverBI01010001010000000000000515BI01000011469.36sqm
351.0349.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mmBI01010001010000000000000515BI010000114722no
361.0359.100.1 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mmBI01010001010000000000000515BI010000114811no
371.03650.9.15.1 : Supplying and fixing 200 mm Aluminium aldropBI01010001010000000000000515BI010000114911no
381.03750.9.15.5 : Providing and fixing iron hooks and eyes: 100 mmBI01010001010000000000000515BI0100001150210no
391.038od433442/2019_2020 : Providing and fixing Name BoardBI01010001010000000000000515BI01000011511no
402ELECTRIFICATIONBI01010001010000000000000515BI0100001152
412.00190.2.1.1 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).BI01010001010000000000000515BI010000115326point
422.00290.2.1.3 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).BI01010001010000000000000515BI01000011541point
432.00390.2.1.4 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).BI01010001010000000000000515BI010000115524point
442.00490.2.1.5 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).BI01010001010000000000000515BI01000011561point
452.00590.2.1.6 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light pointsBI01010001010000000000000515BI01000011578each
462.00690.2.1.7 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short pointBI01010001010000000000000515BI01000011588each
472.00790.3.20.3 : Supply & installation of light fittings on TW round block\t<br>\t\t\t\t\t\nSupply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.BI01010001010000000000000515BI010000115924each
482.0081.58 : Supplying and fixing PVC batten/ angle holder including connection etc. as required.BI01010001010000000000000515BI01000011601each
492.009od811040/2020_2021 : Supplying and fixing 9W LED Bulb. as requiredBI01010001010000000000000515BI01000011611each
502.01od811049/2020_2021 : Supply and fixing 200mm plastic sill shadeBI01010001010000000000000515BI01000011621each
512.01190.3.18.1 : Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.BI01010001010000000000000515BI01000011631metre
522.01290.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)BI01010001010000000000000515BI01000011642each
532.01390.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.BI01010001010000000000000515BI01000011658each
542.01490.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.BI01010001010000000000000515BI010000116624each
552.01590.5.1.8 : Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.BI01010001010000000000000515BI01000011671each
562.0161.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)BI01010001010000000000000515BI01000011681each
572.0171.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)BI01010001010000000000000515BI01000011698each
582.0181.23.5 : Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 amp socket outletBI01010001010000000000000515BI01000011701each
592.0191.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switchBI01010001010000000000000515BI01000011711each
602.0290.10.3.17 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )BI01010001010000000000000515BI010000117224each
612.0211.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switchBI01010001010000000000000515BI010000117316each
622.02290.6.10.2 : Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as requiredBI01010001010000000000000515BI010000117420metre
632.02390.6.10.1 : Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as requiredBI01010001010000000000000515BI0100001175100metre
642.0241.17.2 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mmBI01010001010000000000000515BI010000117655metre
652.0251.17.4 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mmBI01010001010000000000000515BI010000117745metre
662.0261.17.11 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mmBI01010001010000000000000515BI010000117815metre
672.0271.17.22 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mmBI01010001010000000000000515BI010000117930metre
682.02890.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as requiredBI01010001010000000000000515BI01000011801each
692.02990.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as requiredBI01010001010000000000000515BI01000011812each
702.032.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 ampsBI01010001010000000000000515BI01000011823each
712.0312.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual \n current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 ampsBI01010001010000000000000515BI01000011831each
722.0322.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual \n current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 ampsBI01010001010000000000000515BI01000011842each
732.0332.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple poleBI01010001010000000000000515BI01000011852each
742.0342.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single poleBI01010001010000000000000515BI010000118630each
752.03590.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.BI01010001010000000000000515BI010000118715metre
762.03690.12.5.40 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.BI01010001010000000000000515BI010000118815metre
772.03790.12.10.2 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavationBI01010001010000000000000515BI010000118915metre
782.0389.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 10 sq. mm (25mm)BI01010001010000000000000515BI010000119010set
792.0395.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.BI01010001010000000000000515BI01000011912set
802.04od812320/2020_2021 : Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plateBI01010001010000000000000515BI01000011928metre
812.041od812344/2020_2021 : Supply, providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing systemBI01010001010000000000000515BI01000011930.4metre
822.04290.16.1.1 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as requiredBI01010001010000000000000515BI010000119480metre
832.04390.16.1.2 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as requiredBI01010001010000000000000515BI010000119550metre
842.04490.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as requiredBI01010001010000000000000515BI010000119630metre
852.04590.16.5.1 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.BI01010001010000000000000515BI010000119718each
862.04690.16.5.2 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.BI01010001010000000000000515BI010000119812each
872.04790.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.BI01010001010000000000000515BI01000011996each
882.048od812762/2020_2021 : Supply and providing 12x3mm brass nut and bolt etc. as required.BI01010001010000000000000515BI010000120012each
892.049od812766/2020_2021 : Supply and providing 25x6mm brass nut and bolt etc. as required.BI01010001010000000000000515BI01000012016each
902.0590.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br>\nFabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.BI01010001010000000000000515BI01000012020.5sqm
912.05190.14.3.1 : Supply and providing heavy duty 'A' section neoprene gasket in the panel boardBI01010001010000000000000515BI01000012031metre
922.0522.1.2 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & NBI01010001010000000000000515BI01000012041each
932.053od812831/2020_2021 : Supply, threading ,laying and jointing of the 50 mm &quot;B&apos; class GI pipe with all required accessories in ground in he existing trench as protective covering to UG CablBI01010001010000000000000515BI01000012052metre
942.0541.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mmBI01010001010000000000000515BI01000012065metre
952.055od812902/2020_2021 : Supply &amp; installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB-6535)[650 x 350 x 250] and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as requiredBI01010001010000000000000515BI01000012071each
962.056od812914/2020_2021 : Supplying and fixing 100A, HRC Fuse with HRC Fuse link with connections, in existing meter boardBI01010001010000000000000515BI01000012083each
972.057od812920/2020_2021 : Supplying and fixing 100 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter boardBI01010001010000000000000515BI01000012091each

AI Tender Summary

OUR REF NO 26747269
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 05-02-2021
Authority
Authority Name Kerala Institute Of Local Administration
Work Description Kiifb Project ( 2019-20 ) Infrastructure Development Of School , Vengara Lac - Construction Of Building For Ghs Kolappuram - Ar Nagar
Basic Detail
Tender No CM/KILA/KIIFB/PMU/4/REGION2
Bidding Type Tender
Location
City Kolappuram
State Kerala
Key Dates
Publish Date 28 Jan 2021
Submission Date 05 Feb 2021
Open Date 10 Feb 2021
Finance
Tender Value Ref. Documents
Tender Fee 2800
EMD 50000
Exemption Not Available
Document List
tenderotherdocuments.pdf
8DA2C7D7-B223-4B69-B294-372E69A88187.html
tenderdocumentsandspecialconditions.pdf
Tendernotice_1.pdf
BOQ_581257.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 28, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 05, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 10, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

tenderotherdocuments.pdf

html

8DA2C7D7-B223-4B69-B294-372E69A88187.html

pdf

tenderdocumentsandspecialconditions.pdf

pdf

Tendernotice_1.pdf

xls

BOQ_581257.xls