Up-Gradation And Rehabilitation Of Sewer Network In Zone I Gangtok , Under National River Conservation Plan - Civil Engineering Works For Major Extension And Rehabilitation Works . , EAST SIKKIM-Sikkim

Water Security and Public Health Engineering has published Up-Gradation And Rehabilitation Of Sewer Network In Zone I Gangtok , Under National River Conservation Plan - Civil Engineering Works For Major Extension And Rehabilitation Works . . Submission Date for this Tender is 25-02-2021. Sewerage Construction Tenders in EAST SIKKIM Sikkim. Bidders can get complete Tender details and download the document.




Tender Notice

26730040
Up-Gradation And Rehabilitation Of Sewer Network In Zone I Gangtok , Under National River Conservation Plan - Civil Engineering Works For Major Extension And Rehabilitation Works .
Open Tender
Indian
Sikkim
EAST SIKKIM
25-02-2021

Tender Details

Up-Gradation And Rehabilitation Of Sewer Network In Zone I Gangtok , Under National River Conservation Plan - Civil Engineering Works For Major Extension And Rehabilitation Works .

Key Value

Document Fees
INR 200000 /-
EMD
INR 9354519.0 /-
Tender Value
INR 37.41 Crore /-

BOQ Items

Name of Work: Up-gradation & Rehabilitation of Sewer Network in Zone I Gangtok, under National River Conservation Plan - Civil Engineering Works for Major Extension & Rehabilitation works
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Part 1-Cost of Civil Engineering Works for Major Extension & Rehabilitation works BI01010001010000000000000515BI0100001112
2 1.01 Hill cutting in mixed soil 70% and soft rock 30% including throwing of spoils for 50m lead and 1.5m lift all complete and disposal of debris within 15 KM As per Annexure XII BI01010001010000000000000515BI0100001113 0.0001 Rm
3 1.02 Laying of Ductile Iron (K7) pipes with sand bedding keeping an invert depth of 1.50 mtrs. Providing & filling of trench with clean course sand, pipe laying and jointing, providing anchor blocks of varying sizes of 1:2:4 Cement Concrete in Plum and carriage of Stock Material within 5 km radius and Non Stock Material within 40 kms to the work site - (vide Annexure II) BI01010001010000000000000515BI0100001114
4 1.03 150 mm dia - Annexure II (A) (i) BI01010001010000000000000515BI0100001115 5998.14 Rm
5 1.04 150 mm dia - Annexure II (A) (ii) BI01010001010000000000000515BI0100001116 4907.57 Rm
6 1.05 200 mm dia - Annexure II (B) (i) BI01010001010000000000000515BI0100001117 4094.21 Rm
7 1.06 200 mm dia - Annexure II (B) (ii) BI01010001010000000000000515BI0100001118 3349.81 Rm
8 1.07 250mm dia - Annexure II (C) (i) BI01010001010000000000000515BI0100001119 6447.63 Rm
9 1.08 250mm dia - Annexure II (C) (ii) BI01010001010000000000000515BI0100001120 5275.33 Rm
10 1.09 300mm dia - Annexure II (D) (i) BI01010001010000000000000515BI0100001121 1367.3 Rm
11 1.1 300mm dia - Annexure II (D) (ii) BI01010001010000000000000515BI0100001122 1118.7 Rm
12 1.11 350mm dia - Annexure II (E) (i) BI01010001010000000000000515BI0100001123 1498 Rm
13 1.12 350mm dia - Annexure II (E) (ii) BI01010001010000000000000515BI0100001124 0.0001 Rm
14 1.13 Laying of SN8 DWC Pipes with sand bedding keeping an invert depth of 1.50 mtrs. Providing & filling of trench with clean course sand, pipe laying and jointing,and carriage of Stock Material within 15 km radius and Non Stock Material within 40 kms to the work site - (vide Annexure XIV) BI01010001010000000000000515BI0100001125 0.0001 Rm
15 1.14 Shoring of trench size 1.00 x 3.00 x 2.00 m with 38 mm thick cement planks of local wood in Uttis etc. of 1.83 and 150 mm wide- (vide Annexure X) BI01010001010000000000000515BI0100001126 25542.5 Rm
16 1.15 Construction of Manhole Chambers of various sizes. Providing hand packed stone soling; 1:3:6/1:2:4mix cement concrete work i/c shuttering centring etx all complete; providing & laying 1:2:4/1:1.5:3 mix of reinforced cement concrete excluding the cost of formwork; supplying bending & binding tor steel reinforcement in all RCC works i/c the cost of binding wires; providing cement plaster as aspecified i/c finishing even and smooth & curing etc all complete Carriage of Stock Materials (within 15 kms) and Non Stock Materials (within 40 kms) - (vide Annexure III) BI01010001010000000000000515BI0100001127
17 1.16 Type "1E", Size - 1.0 m x 1.0 m x 1.2 m - Annexure III A (i) BI01010001010000000000000515BI0100001128 364 Nos
18 1.17 Type "1E", Size - 1.0 m x 1.0 m x 1.2 m - Annexure III A (ii) BI01010001010000000000000515BI0100001129 212 Nos
19 1.18 Type "1D", Size - 1.2 m x 1.2 m x 1.5 m - Annexure III A (i) BI01010001010000000000000515BI0100001130 336 Nos
20 1.19 Type "1D", Size - 1.2 m x 1.2 m x 1.5 m - Annexure III A (ii) BI01010001010000000000000515BI0100001131 470 Nos
21 1.2 Type "1C", Size - 1.2 m x 1.2 m x 2 m- Annexure III A (i) BI01010001010000000000000515BI0100001132 45 Nos
22 1.21 Type "1C", Size - 1.2 m x 1.2 m x 2 m- Annexure III A (ii) BI01010001010000000000000515BI0100001133 36 Nos
23 1.22 Type "1B", Size - 1.2 m x 1.2 m x 2.5 m - Annexure III A (i) BI01010001010000000000000515BI0100001134 25 Nos
24 1.23 Type "1B", Size - 1.2 m x 1.2 m x 2.5 m - Annexure III A (ii) BI01010001010000000000000515BI0100001135 20 Nos
25 1.24 Type "1A", Size - 1.2 m x 1.2 m x 3 m - Annexure III A (i) BI01010001010000000000000515BI0100001136 14 Nos
26 1.25 Type "1A", Size - 1.2 m x 1.2 m x 3 m- Annexure III A (ii) BI01010001010000000000000515BI0100001137 11 Nos
27 1.26 Repair & Renovation of Manhole Chamber to facilitate Rehabilitation Works - (Vide Annexure XV) BI01010001010000000000000515BI0100001138
28 1.27 Type "1A", Size - 1.2 m x 1.2 m x 3.0 m - Annexure XV A (i) BI01010001010000000000000515BI0100001139 9 Nos
29 1.28 Type "1A", Size - 1.2 m x 1.2 m x 3.0 m - Annexure XV A (Ii) BI01010001010000000000000515BI0100001140 17 Nos
30 1.29 Type "1B", Size - 1.2 m x 1.2 m x 2.5 m - Annexure XV B (i) BI01010001010000000000000515BI0100001141 18 Nos
31 1.3 Type "1B", Size - 1.2 m x 1.2 m x 2.5 m - Annexure XV B (iI) BI01010001010000000000000515BI0100001142 34 Nos
32 1.31 Type "1C", Size - 1.2 m x 1.2 m x 2 m - Annexure XV C (i) BI01010001010000000000000515BI0100001143 49 Nos
33 1.32 Type "1C", Size - 1.2 m x 1.2 m x 2 m - Annexure XV C (iI) BI01010001010000000000000515BI0100001144 174 Nos
34 1.33 Type "1D", Size - 1.2 m x 1.2 m x 1.5 m - Annexure XV D (i) BI01010001010000000000000515BI0100001145 500 Nos
35 1.34 Type "1D", Size - 1.2 m x 1.2 m x 1.5 m - Annexure XV D (iI) BI01010001010000000000000515BI0100001146 594 Nos
36 1.35 Type "1A", Size - 1.2 m x 1.2 m x 3.0 m - Annexure XV E (i) BI01010001010000000000000515BI0100001147 2 Nos
37 1.36 Type "1A", Size - 1.2 m x 1.2 m x 3.0 m - Annexure XV E (Ii) BI01010001010000000000000515BI0100001148 8 Nos
38 1.37 Type "1B", Size - 1.2 m x 1.2 m x 2.5 m - Annexure XV F (i) BI01010001010000000000000515BI0100001149 3 Nos
39 1.38 Type "1B", Size - 1.2 m x 1.2 m x 2.5 m - Annexure XV F (iI) BI01010001010000000000000515BI0100001150 12 Nos
40 1.39 Type "1C", Size - 1.2 m x 1.2 m x 2 m - Annexure XV G (i) BI01010001010000000000000515BI0100001151 30 Nos
41 1.4 Type "1C", Size - 1.2 m x 1.2 m x 2 m - Annexure XV G (iI) BI01010001010000000000000515BI0100001152 120 Nos
42 1.41 Type "1D", Size - 1.2 m x 1.2 m x 1.5 m - Annexure XV H (i) BI01010001010000000000000515BI0100001153 70 Nos
43 1.42 Type "1D", Size - 1.2 m x 1.2 m x 1.5 m - Annexure XV H (iI) BI01010001010000000000000515BI0100001154 280 Nos
44 1.43 Construction of Inspection Chambers of size 600mm x 600mm x 600mm depth. Providing hand packed stone soling; 1:3:6 mic cement concrete work i/c shuttering centring etx all complete; providing & laying 1:2:4 mix of reinforced cement concrete excluding the cost of formwork; supplying bending & binding tor steel reinforcement in all RCC works i/c the cost of binding wires; providing 12.5 mm thick cement plaster of 1:4 mixin single coat i/c finishing even and smooth & curing etc all complete BI01010001010000000000000515BI0100001155
45 1.44 Size - 600mm x 600mm x 600m - Annexure IV A (i) BI01010001010000000000000515BI0100001156 59 Nos
46 1.45 Size - 600mm x 600mm x 600m - Annexure IV A (iI) BI01010001010000000000000515BI0100001157 28 Nos
47 1.46 Size - 600mm x 600mm x 900m - Annexure IV B (i) BI01010001010000000000000515BI0100001158 55 Nos
48 1.47 Size - 600mm x 600mm x 900m - Annexure IV B (Ii) BI01010001010000000000000515BI0100001159 45 Nos
49 1.48 Construction of Reinforced Cement Concrete Beam Bridge of size 0.45 m x 0.45 m x 6.00 m (height) (2 Nos) of beam length 16 mtrs. Providing & laying hand packed stone soling (6"), 1:3:6 Cement Concrete (4"), Providing and laying 1:2:4 RCC excluding cost of formwork, finishing & reinforcement, Supplying bending and binding in position Tor Steel Reinforcement in all RCC Works i/c cost of binding wires etc all complete. BI01010001010000000000000515BI0100001160
50 1.49 Annexure VI (i) BI01010001010000000000000515BI0100001161 0.0001 Nos
51 1.5 Annexure VI (iI) BI01010001010000000000000515BI0100001162 4 Nos
52 1.51 Provision for drains - (vide Annexure XII) BI01010001010000000000000515BI0100001163
53 1.52 Providing Box Drain of 60 cm (ht) x 45 cm (width) of internal dimension as per sepcifications for this item in SOR 12, PWD, Govt. of Sikkim BI01010001010000000000000515BI0100001164 470 Rm
54 1.53 Providing Box Drain of 40 cm (ht) x 30 cm (width) of internal dimension as per sepcifications for this item in SOR 12, PWD, Govt. of Sikkim BI01010001010000000000000515BI0100001165 75 Rm
55 1.54 Providing "U" as per sepcifications for this item in SOR 12, PWD, Govt. of Sikkim BI01010001010000000000000515BI0100001166 0.0001 Rm
56 1.55 Construction of RCC Pillar Support of size as specified below of height 2.40 m. Providing and layin RCC of 1:2:4 excluding the cost of formwork finishing & reinforcement, Supplying bending and binding in position Tor Steel Reinforcement in all RCC works i/c the cost of binding wires etc all complete Carriage of Stock Materials (within 5 kms) and Non Stock Materials (within 30 kms) with an Average Head Load of 100 mtrs (vide Annexure V). BI01010001010000000000000515BI0100001167
57 1.56 size 300 mm x 300 mm - Annexure V A (i) BI01010001010000000000000515BI0100001168 0.0001 Nos
58 1.57 size 300 mm x 300 mm - Annexure V A (ii) BI01010001010000000000000515BI0100001169 41 Nos
59 1.58 size 450 mm x 500 mm - Annexure V B (i) BI01010001010000000000000515BI0100001170 0.0001 Nos
60 1.59 size 450 mm x 500 mm - Annexure V B (ii) BI01010001010000000000000515BI0100001171 15 Nos
61 1.6 Construction of damaged Cement Concrete footpath with hand packed stone soling (6") and Cement Concrete (4") works of 1:3:6 mix for a width of 1.00 mtr. Carriage of Stock Materials (within 5 kms) and Non Stock Materials (within 30 kms) Average head load of 100 mtrs (vide Annexure VII). BI01010001010000000000000515BI0100001172
62 1.61 1.066m wide - Annexure VII A (i) BI01010001010000000000000515BI0100001173 2318.11 Rm
63 1.62 1.066m wide - Annexure VII A (ii) BI01010001010000000000000515BI0100001174 1896.64 Rm
64 1.63 1.52m wide - Annexure VII B (i) BI01010001010000000000000515BI0100001175 1517.41 Rm
65 1.64 1.52m wide - Annexure VII B (ii) BI01010001010000000000000515BI0100001176 1241.51 Rm
66 1.65 1.066 wide with cladding - Annexure VII C (i) BI01010001010000000000000515BI0100001177 201.3 Rm
67 1.66 1.066 wide with cladding - Annexure VII C (ii) BI01010001010000000000000515BI0100001178 164.7 Rm
68 1.67 1.52m wide with cladding - Annexure VII D (i) BI01010001010000000000000515BI0100001179 86.625 Rm
69 1.68 1.52m wide with cladding - Annexure VII D (ii) BI01010001010000000000000515BI0100001180 70.875 Rm
70 1.69 Road Restoration works BI01010001010000000000000515BI0100001181
71 1.7 Road Restoration with 20 mm premix carpetting and seal coat - vide Annexure IX (a) BI01010001010000000000000515BI0100001182 9595.52 Rm
72 1.71 Road restoration works with 60mm Dense Graded Bitumonous Macadam and 40mm Bitumionous Concrete Wearing Course - vide Annexure IX (b) BI01010001010000000000000515BI0100001183 6214 Rm
73 1.72 Construction of Retaining wall in Plum Cement Concrete of 1:2:4 Cement Concrete mix with 50 % clean hard stone sizes not exceeding 15 cm i/c shuttering, compacting & curing etc all complete. Carriage of Stock Materials (within 15 kms) and Non Stock Materials (within 40 kms) & Head Load as specified - as per sepcified heights - (vide Annexure VIII) BI01010001010000000000000515BI0100001184
74 1.73 1.5m height - Annexure VIII A (i) BI01010001010000000000000515BI0100001185 168 Rm
75 1.74 1.5m height - Annexure VIII A (ii) BI01010001010000000000000515BI0100001186 672 Rm
76 1.75 2.0m height - Annexure VIII B (i) BI01010001010000000000000515BI0100001187 242 Rm
77 1.76 2.0m height - Annexure VIII B (ii) BI01010001010000000000000515BI0100001188 968 Rm
78 1.77 3.0m height - Annexure VIII C (i) BI01010001010000000000000515BI0100001189 243 Rm
79 1.78 3.0m height - Annexure VIII C (ii) BI01010001010000000000000515BI0100001190 972 Rm
80 1.79 PART 2 - Rennovation of 4.69 MLD STP, Adampool Gangtok Zone I BI01010001010000000000000515BI0100001191
81 1.8 Repairing of Flow transmitter including laying of cable if needed with necessary termination of cable with changing of terminals push buttons to working condition and commissioning BI01010001010000000000000515BI0100001192 1 nos
82 1.81 Repairing of incoming gates. ( Removing, dismantling, servicing required, oiling and greasing excluding materials) . BI01010001010000000000000515BI0100001193 4 nos
83 1.82 Repairing of grit classifier. (Removing, making of shaft with pionium and coupling , oiling greasing and fixing the same excluding materials. BI01010001010000000000000515BI0100001194 1 nos
84 1.83 Repairing or replacing of gear box of Grit Classifier including shaft oiling and greasing, totally fixing with required gear ratio for proper functioning and commissioning. Gear box totally broken) BI01010001010000000000000515BI0100001195 1 nos
85 1.84 Repairing of Grit separator With gear box, checking of Scraper with rubber squeezer replacing, fixing of Gear box with motor with total servicing BI01010001010000000000000515BI0100001196 1 nos
86 1.85 Servicing of belt conveyor with gear box, motor , oiling and greasing and bring the unit to operation with required operation (including material) BI01010001010000000000000515BI0100001197 1 nos
87 1.86 Repairing of Mechanical Jash Screen and Jash Screen Electrical panel with change in bearing terminal points switches display lights , resisting springs, rollersand fixing of bars as per requirement and brining the unit in operation. (including material) BI01010001010000000000000515BI0100001198 1 nos
88 1.87 Flushing of MBBR tank 1 and 2 with clearing of airline choke for maintaining proper Dissolved Oxygen in both the tank and bringing the tank to proper operation. BI01010001010000000000000515BI0100001199 2 nos
89 1.88 Repairing of Claritube Settler bridge with Gear box repairing , fixing of rail, chain drive, roller bearing Changing of spares of CTS panel with motor fixing , oiling, greasing and bringing the Claritube settler system to operation. BI01010001010000000000000515BI0100001200 1 nos
90 1.89 Ordering and fixing of missing tubemedia from manufacturer and arranging as per needed for proper functioning of tube media BI01010001010000000000000515BI0100001201 1 MTR.
91 1.9 Supply and fixing of 2 nos Submersible pumps in Sludge sump with required specifications and fixing of piping line as per requirement. BI01010001010000000000000515BI0100001202 2 nos
92 1.91 Repairing of 2 nos Centrifuge with required bearing oiling and greasing, with Centrifuge panel repairing and fixing with proper operation. BI01010001010000000000000515BI0100001203 2 nos
93 1.92 Servicing of 3 nos Air blowers with filters, bearing lobe servicing blower alignment or any thing required for proper functioning of blowers with installation of new pressure gauges. BI01010001010000000000000515BI0100001204 3 nos
94 1.93 Total plant lighting change with junction box and internal termal , capacitors resistors, etc with cable replacing if damaged and replace light fitting to LED lights including materials BI01010001010000000000000515BI0100001205 1 lot
95 1.94 Painting of all civil structures and mechanical units including Structural steel cable tray supports pipe supports, piping for total painting of 4.69 MLD STP.(including materials) BI01010001010000000000000515BI0100001206 1 lot
96 1.95 Reparing of MCC Panel with required Fuses, indication lights, push buttons, RRCB, MCB etc for proper functioning of the plant. BI01010001010000000000000515BI0100001207 1 lot
97 1.96 Supply of Office table, Chairs, almirah, refilling of Fire extinguishers. BI01010001010000000000000515BI0100001208 1 lot
98 1.97 Clearing of drying bed BI01010001010000000000000515BI0100001209 1 lot
99 1.98 Clearing of all retaining tanks BI01010001010000000000000515BI0100001210 1 Lump Sum
100 1.99 Provision for lab equipments & chemicals BI01010001010000000000000515BI0100001211 1 Lump Sum
101 2 Provision for Diversion BI01010001010000000000000515BI0100001212 1 Lump Sum
102 2.01 PART 3 - Renovation of 3.9 MLD Plant, Sichey, GANGTOK BI01010001010000000000000515BI0100001213
103 2.02 Repairing of Flow transmitter including laying of cable if needed with necessary termination of cable with changing of terminals push buttons to working condition and commissioning BI01010001010000000000000515BI0100001214 1 nos
104 2.03 Repairing of incoming gates. ( Removing, dismantling, servicing required, oiling and greasing excluding materials) . BI01010001010000000000000515BI0100001215 4 nos
105 2.04 Repairing of grit classifier. Total arrangement to be taken out , fabrication of arm, shaft , flywheel, total alignment and erection.(Removing, making of shaft with pinion and coupling , oiling greasing and fixing the same excluding materials. BI01010001010000000000000515BI0100001216 1 nos
106 2.05 Repairing or replacing of gear box of Grit Classifier including shaft oiling and greasing, totally fixing with required gear ratio for proper functioning and commissioning. Gear box totally broken) BI01010001010000000000000515BI0100001217 1 nos
107 2.06 Repairing of Grit separator With gear box, checking of Scraper with rubber squeezer replacing, fixing of Gear box with motor with total servicing BI01010001010000000000000515BI0100001218 1 nos
108 2.07 Servicing of belt conveyor with gear box, motor , oiling and greasing and bring the unit to operation with required operation (including material) BI01010001010000000000000515BI0100001219 1 nos
109 2.08 Repairing of Mechanical Jash Screen and Jash Screen Electrical panel with change in bearing terminal points switches display lights , resisting springs, roller sand fixing of bars as per requirement and brining the unit in operation. (including material) BI01010001010000000000000515BI0100001220 1 nos
110 2.09 Flushing of MBBR tank 1 and 2 with clearing of airline choke for maintaining proper Dissolved Oxygen in both the tank and bringing the tank to proper operation. BI01010001010000000000000515BI0100001221 2 nos
111 2.1 Repairing of Claritube Settler bridge with Gear box repainting , fixing of rail, chain drive, roller bearing Changing of spares of CTS panel with motor fixing , oiling, greasing and bringing the Claritube settler system to operation. BI01010001010000000000000515BI0100001222 1 nos
112 2.11 Clearing of tank with fixing rubber squeezer, checking of scraper alignment, and epoxy painting of structural trusses. BI01010001010000000000000515BI0100001223 1 lot
113 2.12 Servicing and fixing of 2 nos Screw pumps, checking of rotor and stator in Sludge sump with required specifications and fixing of piping line as per requirement. BI01010001010000000000000515BI0100001224 2 nos
114 2.13 Repairing of 1 nos Centrifuge with required bearing oiling and greasing, with Centrifuge panel , if VFD is ok or not repairing and fixing with proper operation. BI01010001010000000000000515BI0100001225 1 nos
115 2.14 Servicing of 3 nos Air blowers with filters, bearing lobe servicing blower alignment or anything required for proper functioning of blowers with installation of new pressure gauges. BI01010001010000000000000515BI0100001226 3 nos
116 2.15 Total plant lighting change with junction box and internal termal , capacitors resistors, etc with cable replacing if damaged and replace light fitting to LED lights including materials BI01010001010000000000000515BI0100001227 1 lot
117 2.16 Painting of all civil structures and mechanical units including Structural steel cable tray supports pipe supports, piping for total painting of 4.69 MLD STP.(including materials) BI01010001010000000000000515BI0100001228 1 lot
118 2.17 Repairing of MCC Panel with required Fuses, indication lights, push buttons, RRCB, MCB etc for proper functioning of the plant. BI01010001010000000000000515BI0100001229 1 lot
119 2.18 Checking of chlorination system and Polydosing system, oiling of pumps, servicing and arranging piping as per required. Changing of HDPE pipe arrangement to UPVC pipe for better functioning with proper structural support and clamps. BI01010001010000000000000515BI0100001230 1 lot
120 2.19 Clearing of drying bed BI01010001010000000000000515BI0100001231 1 lot
121 2.2 Clearing of all retaining tanks BI01010001010000000000000515BI0100001232 1 Lump Sum
122 2.21 Provision for lab equipments & chemicals BI01010001010000000000000515BI0100001233 1 Lump Sum
123 2.22 Provision for Diversion BI01010001010000000000000515BI0100001234 1 Lump Sum
124 2.23 PART 4 - Renovation of 8 MLD Plant, Adampool, Gangtok Zone I BI01010001010000000000000515BI0100001235
125 2.24 Repairing of incoming gates. (Removing, dismantling, servicing required, oiling and greasing excluding materials) . BI01010001010000000000000515BI0100001236 4 nos
126 2.25 Repairing of grit classifier, servicing, oiling changing of bearings, rollers .(Removing, making of shaft with pinion and coupling , oiling greasing and fixing the same. BI01010001010000000000000515BI0100001237 1 nos
127 2.26 Repairing of Grit Separator With gear box, checking of Scraper with rubber squeezer replacing, fixing of Gear box with motor with total servicing BI01010001010000000000000515BI0100001238 1 nos
128 2.27 Flushing of MBBR tank 1 and 2 with clearing of airline choke for maintaining proper Dissolved Oxygen in both the tank and bringing the tank to proper operation. BI01010001010000000000000515BI0100001239 2 nos
129 2.28 Repairing of Claritube Settler bridge with Gear box repainting , fixing of rail, chain drive, roller bearing Changing of spares of CTS panel with motor fixing , oiling, greasing and bringing the Claritube settler system to proper operation. BI01010001010000000000000515BI0100001240 1 nos
130 2.29 Clearing of tank with fixing rubber squeezer, checking of scraper alignment, etc for proper functioning of CTS. BI01010001010000000000000515BI0100001241 1 lot
131 2.3 Supply and fixing of 2 nos Submersible pumps in Sludge sump with required specifications and fixing of piping line as per requirement. BI01010001010000000000000515BI0100001242 2 nos
132 2.31 Servicing of 3 nos Air blowers with filters, bearing lobe servicing blower alignment or anything required for proper functioning of blowers with installation of new pressure gauges. BI01010001010000000000000515BI0100001243 3 nos
133 2.32 Repairing of 1 nos Centrifuge with required bearing oiling and greasing, with Centrifuge panel , if VFD is ok or not repairing and fixing with proper operation. BI01010001010000000000000515BI0100001244 1 nos
134 2.33 Total plant lighting change with junction box and internal thermal , capacitors resistors, etc with cable replacing if damaged and replace light fitting to LED lights including materials BI01010001010000000000000515BI0100001245 1 lot
135 2.34 Painting of all civil structures and mechanical units including Structural steel cable tray supports pipe supports, piping for total painting of 8 MLD STP.(including materials) BI01010001010000000000000515BI0100001246 1 lot
136 2.35 Repairing of MCC Panel with required Fuses, indication lights, push buttons, RRCB, MCB etc for proper functioning of the plant. BI01010001010000000000000515BI0100001247 1 lot
137 2.36 Clearing of drying bed BI01010001010000000000000515BI0100001248 1 lot
138 2.37 Clearing of all retaining tanks BI01010001010000000000000515BI0100001249 1 Lump Sum
139 2.38 Provision for lab equipments & chemicals BI01010001010000000000000515BI0100001250 1 Lump Sum
140 2.39 Provision for Diversion BI01010001010000000000000515BI0100001251 1 Lump Sum
141 2.4 PART 5 - Construction of Holding Tank (Activating Trickling Filter System), and Other Reconditioning and Augmentation Works in STP Complex in Adampool BI01010001010000000000000515BI0100001252
142 2.41 Clearing of HRTF and ST of debris. BI01010001010000000000000515BI0100001253 2400 mandays
143 2.42 Chipping/Dismantelling of old RCC flooring and the plasters of wall etc and throwing of debris in designated place by mannual means. BI01010001010000000000000515BI0100001254 10800 mandays
144 2.43 P/Laying 1:1.5:3 RCC in position specified grade of reinforced cement concrete excluding the cost of formwork,finishing and reinforcement. BI01010001010000000000000515BI0100001255 516.57 cum
145 2.44 S/B/B in reinforcement in RCC wprks including cost of binding wire al complete BI01010001010000000000000515BI0100001256 774.86 qtls
146 2.45 P/L 20 mm thick cc plaster in 1 : 3 mix i/c finishing even and smooth anad curing etc all complete. BI01010001010000000000000515BI0100001257 2357.68 sqm
147 2.46 Carriage of Stock Materials BI01010001010000000000000515BI0100001258
148 2.47 Loading and Unloading of stock Materials by Manual means or stacking. BI01010001010000000000000515BI0100001259 1011.51 MT
149 2.48 Cost of Haulage (10km) BI01010001010000000000000515BI0100001260 1011.51 MT
150 2.49 Carriage of non stock materials to work site within 40KM for particular BI01010001010000000000000515BI0100001261
151 2.5 Loading and Unloading of Non-stock Materials by Manual means or stacking (sand) BI01010001010000000000000515BI0100001262 495.67 cum
152 2.51 Loading and Unloading of Non-stock Materials by Manual means or stacking (stone) BI01010001010000000000000515BI0100001263 439.09 cum
153 2.52 Cost of Haulage BI01010001010000000000000515BI0100001264 1892.9 MT
154 2.53 Provision for making floor scrubber for sedimentation tank inclusive of motor mechanism BI01010001010000000000000515BI0100001265 2 Lump Sum
155 2.54 Provision for making inlet with screen and outlets for each tank including intallation of control valves \t\t\t\t\t\t BI01010001010000000000000515BI0100001266 1 Lump Sum
156 2.55 Provision for repair of electrifiation line etc. at STP Zone 1, inclusive of provision for supply and installation of backup inverter BI01010001010000000000000515BI0100001267 1 Lump Sum
157 2.56 Provision for reconditioning of pipes BI01010001010000000000000515BI0100001268 1 Lump Sum
158 2.57 Repair of pump House BI01010001010000000000000515BI0100001269 1 Lump Sum
159 2.58 Laying of 150 mm D.I pipe BI01010001010000000000000515BI0100001270 165 mtr
160 2.59 Construction of manhole chambers 1.2mx1.2mx2m BI01010001010000000000000515BI0100001271 11 nos
161 2.6 Construction of foothpath - 1.52m wide with cladding - Annexure VII D (i) BI01010001010000000000000515BI0100001272 350 mtrs
162 2.61 Provision for fencing to separate plant area from family residential complex BI01010001010000000000000515BI0100001273 450 mtrs
163 2.62 Supply of pipes and fittings inclusive of GST & STCS comm (150mm dia) BI01010001010000000000000515BI0100001274 165 mtrs
164 2.63 Supply of Machines and tools BI01010001010000000000000515BI0100001275
165 2.64 1 HP PUMP BI01010001010000000000000515BI0100001276 2 nos
166 2.65 3 HP PUMP BI01010001010000000000000515BI0100001277 4 nos
167 2.66 5 HP PUMP BI01010001010000000000000515BI0100001278 3 nos
168 2.67 7 HP PUMP BI01010001010000000000000515BI0100001279 3 nos
169 2.68 Grinding machine BI01010001010000000000000515BI0100001280 1 nos
170 2.69 Multimeter BI01010001010000000000000515BI0100001281 1 nos
171 2.7 Ultrasonic Flow meter BI01010001010000000000000515BI0100001282 3 nos
172 2.71 Submersible pump BI01010001010000000000000515BI0100001283 3 nos
173 2.72 Gear box BI01010001010000000000000515BI0100001284 2 nos
174 2.73 Blower belt BI01010001010000000000000515BI0100001285 12 nos
175 2.74 wheel barrow BI01010001010000000000000515BI0100001286 5 nos
176 2.75 18% GST on item no 92 BI01010001010000000000000515BI0100001287 1 Lump Sum
177 2.76 Setting up of new centrifuge system BI01010001010000000000000515BI0100001288
178 2.77 80 mm D.I pipe (inclusive of STCS comm & GST) BI01010001010000000000000515BI0100001289 150 mtr
179 2.78 Pipe jointing BI01010001010000000000000515BI0100001290 150 mtr
180 2.79 Supply of pumps - sumersible ABS-MF 804 DKS or equivalent or others as specified BI01010001010000000000000515BI0100001291 2 nos
181 2.8 18% GST on item no 92.03 BI01010001010000000000000515BI0100001292 1 Lump Sum
182 2.81 Intallation of pump including electrification BI01010001010000000000000515BI0100001293 1 Lump Sum
183 2.82 Provision for Stand-by Blower & Motor BI01010001010000000000000515BI0100001294
184 2.83 Everest Air cooled Blower 710 9complete with all standard accessories) BI01010001010000000000000515BI0100001295 2 nos
185 2.84 Everest 40 HP standard electric motor BI01010001010000000000000515BI0100001296 2 nos
186 2.85 Carraige and packaging BI01010001010000000000000515BI0100001297 1 Lump Sum
187 2.86 18% GST on item no 94.01 & 94.02 BI01010001010000000000000515BI0100001298 1 Lump Sum
188 2.87 Provision for construction chemcials, saftey equipments & clothing BI01010001010000000000000515BI0100001299 1 Lump Sum
189 2.88 Labour Welfare Cess, @ 1% BI01010001010000000000000515BI0100001300 1 Lump Sum
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.