Re-Electrification Of Buffalo Farm Shed No . 2 At Ulf And Frds , Mannuthy, Mannuthy-Kerala

Kerala Veterinary and Animal Sciences University-KVASU has published Re-Electrification Of Buffalo Farm Shed No . 2 At Ulf And Frds , Mannuthy. Submission Date for this Tender is 02-02-2021. Electrification Work Tenders in Mannuthy Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

26726353
Re-Electrification Of Buffalo Farm Shed No . 2 At Ulf And Frds , Mannuthy
Open Tender
Indian
Kerala
Mannuthy
02-02-2021

Tender Details

Re-Electrification Of Buffalo Farm Shed No . 2 At Ulf And Frds , Mannuthy

Key Value

Document Fees
INR 565 /-
EMD
INR 2800.0 /-
Tender Value
Refer document

BOQ Items

Work Name : Re-electrification of Buffalo Farm Shed No.2 at ULF & FRDS, Mannuthy
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Power connection part BI01010001010000000000000515BI0100001113
2 1.01 2.23.4 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 14 way, Double door SPN MCBDB BI01010001010000000000000515BI0100001114 1 each
3 1.02 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps BI01010001010000000000000515BI0100001115 1 each
4 1.03 2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual\ncurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps BI01010001010000000000000515BI0100001116 1 each
5 1.04 2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole BI01010001010000000000000515BI0100001117 5 each
6 1.05 90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) BI01010001010000000000000515BI0100001118 4 each
7 1.06 90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) BI01010001010000000000000515BI0100001119 30 metre
8 1.07 5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required BI01010001010000000000000515BI0100001120 2 set
9 1.08 2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole BI01010001010000000000000515BI0100001121 2 each
10 1.09 90.6.5.14 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 6.00 sq mm BI01010001010000000000000515BI0100001122 40 metre
11 1.1 7.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size direct in ground including excavation, sand cushioning, protective covering and\nrefilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm BI01010001010000000000000515BI0100001123 25 metre
12 1.11 7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) BI01010001010000000000000515BI0100001124 15 metre
13 2 Re- electrification BI01010001010000000000000515BI0100001125
14 2.01 1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC\ninsulated copper conductor single core cable in surface / recessed medium class PVC conduit,\nwith modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS\nPVC insulated copper conductor single core cable etc as required.Group C BI01010001010000000000000515BI0100001126 38 point
15 2.02 1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire BI01010001010000000000000515BI0100001127 60 metre
16 2.03 1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) BI01010001010000000000000515BI0100001128 2 each
17 2.04 1.27.3 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) BI01010001010000000000000515BI0100001129 2 each
18 2.05 1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) BI01010001010000000000000515BI0100001130 2 each
19 2.06 1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) BI01010001010000000000000515BI0100001131 2 each
20 2.07 1.27.6 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm) BI01010001010000000000000515BI0100001132 2 each
21 2.08 1.28.1 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module BI01010001010000000000000515BI0100001133 2 each
22 2.09 1.28.3 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module BI01010001010000000000000515BI0100001134 2 each
23 2.1 1.28.4 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module BI01010001010000000000000515BI0100001135 2 each
24 2.11 1.28.5 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module BI01010001010000000000000515BI0100001136 2 each
25 2.12 1.28.6 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.12 Module BI01010001010000000000000515BI0100001137 2 each
26 2.13 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch BI01010001010000000000000515BI0100001138 38 each
27 2.14 1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required. BI01010001010000000000000515BI0100001139 30 each
28 2.15 1.34 : Supplying and fixing brass batten/ angle holder including connection etc. as required. BI01010001010000000000000515BI0100001140 8 each
29 3 Supply of tube sets, Holder lights and streetlights BI01010001010000000000000515BI0100001141
30 3.01 od243979/2020_2021 : Supply and fixing of 20W LED Tube with fitting. Luker/Philips mushroom 20W all<br>complete. BI01010001010000000000000515BI0100001142 26 no
31 3.02 od243980/2020_2021 : S & F LED Bulb classic 9W on existing batten holder BI01010001010000000000000515BI0100001143 2 no
32 3.03 od243981/2020_2021 : Providing, Installation, testing and commissioning of street light 45W LED (Philips, Bajaj, Luker or Equivalent) BI01010001010000000000000515BI0100001144 2 no
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail