| 1 | 1 | Earth work in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite or sand stone) including removing, spreading or stacking the spoils within a lead of 75m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. | BI01010001010000000000000515BI0100001125 | 215.29 | Cum |
|---|
| 2 | 2 | Laying 150 mm. to 200 mm. boulder soling including rough dressing hand packing and ramming down small pieces in the interstics without rolling but including ramming. | BI01010001010000000000000515BI0100001126 | 192.16 | Sqm |
|---|
| 3 | 3 | Cost of stone boulder 150 mm size delivered ans stacked at site. | BI01010001010000000000000515BI0100001127 | 28.82 | Cum |
|---|
| 4 | 4 | Ordinary cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttring and reinforcement, if any, in ground floor as per relevant IS codes.River bazree | BI01010001010000000000000515BI0100001128 | 10.82 | Cum |
|---|
| 5 | 5 | Rubble masonry in cement (1:6) with hard dressed stones from approved quarries and clean, coarse and washed sand including carriage of all materials to site | BI01010001010000000000000515BI0100001129 | 19.91 | Cum |
|---|
| 6 | 6 | Ordinary cement concrete (mix 1:1.5:3) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant codes. | BI01010001010000000000000515BI0100001130 | 19.11 | Cum |
|---|
| 7 | 7 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction..(a) For works in foundation, basement and upto roof of ground floor/upto 4m.(i) Tor steel/Mild steel.other than SAIL/TATA/RINL | BI01010001010000000000000515BI0100001131 | 1800.16 | Kg |
|---|
| 8 | 8 | Hire and labour charge for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams,columns, lintels curved or staight including fitting fixing and striking out after complection of works. (upto roof of ground floor).(a) 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of the Engineer-in-charge | BI01010001010000000000000515BI0100001132 | 191.78 | Sqm |
|---|
| 9 | 9 | Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 150 mm. including watering and ramming etc.layer by layer complete .(payment to be made on the basis of measurement of finished quantity of work).(a) With earth obtained from excavation of foundation | BI01010001010000000000000515BI0100001133 | 159.28 | Cum |
|---|
| 10 | 10 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:3) in ground floor | BI01010001010000000000000515BI0100001134 | 180.77 | Sqm |
|---|
| 11 | 11 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame excluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be corrected up to three decimals).(i) Other Local Wood. | BI01010001010000000000000515BI0100001135 | 0.13 | Cum |
|---|
| 12 | 12 | panel shutters of door and window, as per design (each panel consisting of single plank with out joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.In ground floor.(In case of non-supply of single plank, panel rate of reduction of 20% will be made).(iii) 35mm.thick shutters with 19 mm. thick panel of size 30 to 45cm.champ. | BI01010001010000000000000515BI0100001136 | 6.15 | Sqm |
|---|
| 13 | 13 | Supplying, fitting and fixing windows and ventilators with or withoutintegrated grills conforming to IS 1038-1975 and manufactured fromrolled steel sections conforming to IS 7452-1974 with non-frictionprojecting type, box type hinges, glazing clips, lugs locking bracket,handle plate etc, including hoisting in position, straightening ifrequired, fixing lugs in cement concrete ( 1:2:4) with stone chips 20mm down cutting holes and mending good damages to match withexisting surface complete in all respect excluding glazing.(Add extra @ 1.2 % for each additional floors upto 4th floor and @1.5% for each addl. Floor above 4th floor.)In Ground floorFlash butt welded windows and ventilators(No shop priming will be allowed to facilitate inspection ofworkmanship)Without (b) Openable steel windows as per IS sizes with side hung shuttersand horizotal glazing bars. [The extra rate admissible for theopenable portion only] | BI01010001010000000000000515BI0100001137 | 12.6 | Sqm |
|---|
| 14 | 14 | Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering conrners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (ground floor).[Excluding cost of chipping over concrete surface].(ii) With 1:4 cement mortar .(a) 20mm.thick plaster. | BI01010001010000000000000515BI0100001138 | 615.68 | Sqm |
|---|
| 15 | 15 | M.S. structural works in roof trusses with tubular sections conforming to IS: 806- 1957 & IS: 1161- 1958 connected to one another with bracket,gusset,cleats as per design, direction of Engineer-In-Charge complete including cutting to requisite size. fabrication with necessary metal arc welding conforming to IS: 816- 1956 & IS: 9595 using electrodes of approved make and brand conforming to IS: 814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section. consumables such as electrodes, gas and hire charges of all tools and plants and labour required for the work including all incidental charges such as electricity charges, labour insurance charges etc.(Payment to be made on the basis of calculated weight of structural tubular members as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with the weight of finished structural members. The rates are considered for a height of erection 8m./ 2nd. floor leves from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initial 8m. or part ther of.(ii) For trusses spanning above 12.00 m and up to 20.00 m. | BI01010001010000000000000515BI0100001139 | 4424.18 | Kg |
|---|
| 16 | 16 | Galvanized corrugated iron sheet work (excluding the supporting frame work) fitted and fixed with 10 mm. dia J or L hook-bolts, limpet and bitumen washers and putty complete with 150 mm. end lap and one corrugaion minimum side lap. ( payment to be made on area of finished work). (GCI sheet to be supplied by contractor) In roof. (a) with 0.60 mm.thick sheet. | BI01010001010000000000000515BI0100001140 | 198.66 | Sqm |
|---|
| 17 | 17 | Galvanised iron sheet ridging fitted with necessary bolt, screws, washers etc complete. (225 mm end lapping).300mm laping each way,with 0.60mm thick sheet. | BI01010001010000000000000515BI0100001141 | 44.45 | Mtr |
|---|
| 18 | 18 | Wooden eaves board as per design, fitted and fixed complete:In ground floor(i) Plain eaves board (Local Sal) (b)25mm thick | BI01010001010000000000000515BI0100001142 | 11.12 | Mtr |
|---|
| 19 | 19 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. and cutting trenches in any soil through masoury concrete structures etc. if necessary and mending good damages including jointing with jointing materials (Spun yarn, valam160mmoid / bitumen/M.seal etc) complete.(A) UPVC PIPES. | BI01010001010000000000000515BI01000011143 | 18 | Mtr |
|---|
| 20 | 20 | UPVC Fitting(b) Plain Y,(iii)160mm dia | BI01010001010000000000000515BI0100001144 | 3 | Nos |
|---|
| 21 | 21 | UPVC Fitting© bend 87.5 degree(iii)160mm dia | BI01010001010000000000000515BI0100001145 | 7 | Nos |
|---|
| 22 | 22 | Applying interior grade acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to received distemper /Acrylic emulsion paint including scraping and preparing the surface thoroughly , complete as per manufactured specification and as per directions of the EIC.In ground floor,(a) one cpat.(i) water based interior grade Acrylic primer. | BI01010001010000000000000515BI0100001146 | 200 | Sqm |
|---|
| 23 | 23 | Applying exterior grade Acrylic primer of approved quality and brand on plaster or concrete surface old or new surface to receive decorative textured (mat finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor:(a) one coat. | BI01010001010000000000000515BI0100001147 | 217.52 | Sqm |
|---|
| 24 | 24 | Acrylic Distemper to interior wall, ceiling with a coat of solvent basedinterior grade acrylic primer (as per manufacturer's specification)including cleaning and smoothning of surface.Two Coats | BI01010001010000000000000515BI0100001148 | 200 | Sqm |
|---|
| 25 | 25 | Protective and decorative Acrylic exterior emulsion paint of approved quality , as per manufacture specification as per direction of EIC to be apply over Acrylic primer as required. the rate included cost of material , labour scaffoldic and all incidential charges but excluding the cost of primer.In ground floor ( two coat).(a) Normal Acrylic emulaion. | BI01010001010000000000000515BI0100001149 | 217.52 | Sqm |
|---|
| 26 | 26 | (b) Priming one coat on timber or plastered surface with synthetic enamel oil bound primer of approved quality including smoothening surfaces by sand papering etc. | BI01010001010000000000000515BI0100001150 | 15.99 | Sqm |
|---|
| 27 | 27 | (a) Priming one coat on steel surface with synthetic enamel oil bound primer of approved quality including smoothening surfaces by sand papering etc. | BI01010001010000000000000515BI0100001151 | 12.6 | Sqm |
|---|
| 28 | 28 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand parpering etc. in cluding using of approved putty etc. on the surface , if necessary.(a) On timber or plastered surface: (1) With super gloss (hi-gloss).(iv) Two coats (with any shade except white). | BI01010001010000000000000515BI0100001152 | 15.99 | Sqm |
|---|
| 29 | 29 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand parpering etc. in cluding using of approved putty etc. on the surface , if necessary.(a) On steel or other metal surface: (1) With super gloss (hi-gloss).(iv) Two coats (with any shade except white). | BI01010001010000000000000515BI0100001153 | 12.6 | Sqm |
|---|
| 30 | 30 | P.V.C- False Ceiling :Providing False Ceiling made with framework of steel tube of 40mm x 20mm ofnot less than 18 gauge,the long and cross section will be welded with each other1000mm to 1200mm apart the entire framework will be fixed in wall usingrawlplug or gutties or screws etc. and suspended from ceiling with M.S flat19mmx3mm as necessary,the entire frame will be painted with red oxide.PRINTED LAMINATED P.V.C Section 150mm x 12mmx 1.00mm (+/- 0.01mm)of approved quality and colour will be fixed on the frame so that the entireframework will not be visible from below P.V.C Section will be fixed with theframe with the help of self tapping steel screws including all materials and labourcharges including fitting,fixing the same and hoisting including mending thedamages in all respect and cost of paint as required as per direction of Engineerin-Charge .In ground floor | BI01010001010000000000000515BI0100001154 | 144 | Sqm |
|---|
| 31 | 31 | supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar , end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction . ( cost of concrete will be paid separately). | BI01010001010000000000000515BI0100001155 | 18 | Nos |
|---|
| 32 | 32 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.(vi) 100mm x 50 mm x 1.25 mm. | BI01010001010000000000000515BI0100001156 | 18 | Nos |
|---|
| 33 | 33 | Anodise aluminium barred/tower/socket bolt (full covered) of approved manufactured from extruded section conforming to I.S.204/74 fitted and Fixed with cadmium plated screws:.(iv)150mmlongx10mm dia bolt. | BI01010001010000000000000515BI0100001157 | 6 | Nos |
|---|
| 34 | 34 | Anodise aluminium Aldrop/Sliding bolts of approved quality manufactured form extruded section conforming to I.S. specifictation (I.S.2681/66) fitted and fixed complete.250mmx19mm dia.bolt. | BI01010001010000000000000515BI0100001158 | 3 | Nos |
|---|
| 35 | 35 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S.230/72) fitted and fixed complete:.(a) With continuous plate base (hexagonal/round rod).100mm gripx12mm dia rod | BI01010001010000000000000515BI0100001159 | 5 | Nos |
|---|
| 36 | 36 | Cost for Sanitary works 10% | BI01010001010000000000000515BI0100001160 | 1 | one item |
|---|
| 37 | 37 | Cost for Electrification works, if any | BI01010001010000000000000515BI0100001161 | 1 | one item |
|---|
| 38 | 38 | GST @12 % | BI01010001010000000000000515BI0100001162 | 1 | one item |
|---|
| 39 | 39 | labour cess 1% | BI01010001010000000000000515BI0100001163 | 1 | one item |
|---|