Military Engineer Services-MES has published Provision Of Certain Senction Rw Work In The Area Of Age B/R-I , Age B/R-Ii And Age E/M Under Ge Sgnr At Military Station Sri Ganganagar. Submission Date for this Tender is 20-02-2021. Civil Work Tenders in GE Sri Ganganagar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

26710002
Corrigendum : Provision Of Certain Senction Rw Work In The Area Of Age B/R-I , Age B/R-Ii And Age E/M Under Ge Sgnr At Military Station Sri Ganganagar
Open Tender
Indian
Rajasthan
GE Sri Ganganagar
20-02-2021

Tender Details

Provision Of Certain Senction Rw Work In The Area Of Age B / R-I , Age B / R-Ii And Age E / M Under Ge Sgnr At Military Station Sri Ganganagar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Jan-2021 amndt1 BOQ 13-02-2021
2 13-Feb-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-02-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 32640.0 /-
Tender Value
INR 16.32 Lakhs /-

BOQ Items

Name of Work: PROVN OF CERTAIN SENCTION RW WORK IN THE AREA OF AGE BR-I, AGE BR-II AND AGE EM UNDER GE SGNR AT MILITARY STATION SRI GANGANAGAR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer - in - Charge 56.1 Cum
2 2 Returning filling in, including spreading levelling, watering and well ramming in layers not exc. 25 cms thick in soft/ loose soil complete all as specified and directed by Engineer - in - Charge. 28.98 Cum
3 3 Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in soft/loose soil complete all as specified and directed by Engineer-in-Charge. 31 Each
4 4 Surface dressing n. exc. 15 cm deep in soft/loose soil complete all as specified and directed by Engineer-in-Charge . 90 Sqm
5 5 Surface dressing n. exc. 30 cm deep and averaging 15 cm deep in soft/loose soil complete all as specified and directed by Engineer-in-Charge . 9 Sqm
6 6 M & L for sand filling (25 mm thick) under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer - in - Charge. 7.7 Cum
7 7 Removing excavated material n. exc. 50 m & depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engineer - in - Charge. 26.62 Cum
8 8 M&L for hard core of gauge exc 63 mm but n. exc 100 mm, deposited spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface using broken bricks complete all as specified and directed by Engineer - in - Charge. 1.85 Cum
9 9 M&L for PCC 1: 2:4 Type B-1 (20mm graded stone aggregate)as in flooring laid in alternate bays complete all as specified and directed by Engineer - in - Charge 7 Cum
10 10 M&L for PCC (1:4:8) type D-2, (40 mm graded stone aggregate) as in foundation complete all as specified and directed by Engineer - in - Charge 20.6 Cum
11 11 M&L for PCC (1:3:6) type C-2, (40 mm graded stone aggregate) as in foundation of posts and struts complete all as specified and directed by Engineer - in - Charge 22.36 Cum
12 12 M&L cement concrete 1:2:4 type B-0 (12.5 mm graded aggregate) as in coping on manhole complete all as specified and directed by Engr-in-charge. 0.1 Cum
13 13 M & L for PCC 1:2:4 Type B –1 (20mm graded stone aggregate) for kerb stone and similar works with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in CM 1:4 with joints to match complete all as specified and directed by Engineer - in - Charge. 5 Cum
14 14 M&L for Pre-cast cement concrete 1: 2:4 Type B-1 (20mm graded stone aggregate)as in block masonry with solid blocks, exc. 10 cm in width and setting as in kerb stone complete all as specified and directed by Engineer - in - Charge 1.42 Cum
15 15 M&L for providing precast cement concrete 1:2:4 Type B1 using 65mm graded aggregate as in cover slabs (for manholes etc) and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and directed by Engineer - in - Charge. 0.05 Cum
16 16 M&L for reinfoced cement concrete Type B-1 (1:2:4) Nominal Mix (20mm graded stone aggregate) as in slabs suphorted on wall, beams and columns in floor/roofs landings, balconies deck slabs, lintels, bands, capings and in shelves and similar work complete all as specified and directed by Engineer - in - Charge. 1.25 Cum
17 17 M&L for reinfoced cement concrete Type B-0 (1:2:4) Nominal Mix (20mm graded stone aggregate) as in slabs suphorted on wall, beams and columns in floor/roofs landings, balconies deck slabs, lintels, bands, capings and in shelves and similar work complete all as specified and directed by Engineer - in - Charge. 0.25 Cum
18 18 M&L for reinfocement cement concrete 1: 2:4 Type B-1 (nominal mix ) (20mm graded stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer - in - Charge 0.65 Cum
19 19 M & L brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer - in - Charge. 25 Cum
20 20 M&L for brick work with Fly ash bricks, straight or curved on plan exc 6 m mean radius in half brick thick walls built in CM 1:6 complete all as specified and directed by Engineer - in - Charge. 4 Sqm
21 21 M&L for Damp proof course to horizontal or vertical surfaces in cement concrete 1:2:4, 12.5 mm thick, type B-o including necessary formwork complete all as specified and directed by Engineer - in - Charge. 1.8 Sqm
22 22 M&L 20mm thick Granite (of any type) (table rubbed and polished) work in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:6) including pointing in white cement (1:2) including Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engr-in-charge. 2 Sqm
23 23 M&L 20mm thick Granite (of any type) (table rubbed and polished) work in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) including Screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in CM 1:6 including making hole in granite slab for gas pipe complete all as specified and directed by Engr-in-charge. 5.5 Sqm
24 24 M&L for form work to sides & soffits of suspended slab such as roof slabs, floor slabs, landings and similar work; n. exc. 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete complete all as specified and directed by Engineer - in - Charge 10 Sqm
25 25 S & F 2nd class clean sawn hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed by Engineer - in - Charge. 0.2 Cum
26 26 S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed by Engineer - in - Charge. 2.8 Sqm
27 27 Taking down shutters of any description exc. 1 Sqm but n.exc 2 sqm each and refixing in the same opening / place after carrying necessary repair complete all as specified and directed by Engineer - in - Charge.. 5 Each
28 28 S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by Engineer - in - Charge. 9.6 RM
29 29 S&F 10 mm thick PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium/ G.I./M.S. as per specification and drawing replaced with wooden ceiling and accessories complete all as specified and directed by Engineer - in - Charge 137 Sqm
30 30 S & F alluminium anodised barrel tower bolts 125mm long extruded section complete all as specified and directed by Engineer - in - Charge. 34 Each
31 31 S & F alluminium anodised barrel tower bolts 150mm long extruded section complete all as specified and directed by Engineer - in - Charge. 4 Each
32 32 S & F butt hinges, medium weight, cold rolled mild steel, and fixed of size 100mm fixing properly with screws etc complete all as specified and directed by Engineer - in - Charge. 12 Each
33 33 S & F aluminium butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 of size 75 mm fixing properly with screws etc complete all as specified and directed by Engineer - in - Charge.. 60 Each
34 34 S & F 125 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer - in - Charge 36 Each
35 35 S & F stainless steel tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by Engineer-in-Charge. 6 Each
36 36 S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer - in - Charge. 0.45 Sqm
37 37 S&F flat iron 40x6 mm for fixing chain link fencing with post and 10 mm dia MS round bar inserting in mesh including hooking etc complete all as specified and directed by Engineer-in-charge. 150 Kg
38 38 S&F mild steel work i.e. angle iron/ flat iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-charge. 1900 Kg
39 39 S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and directed by Engineer-in-charge. 95 Kg
40 40 S&F 10 mm dia MS round bar for fixing of chain link fencing with post complete all as specifies and directedby Engineer - in - Charge. 448 kg
41 41 Supply only chain link fencing galvanised mild steel hot dipped(IS -2721) of 4 mm dia of mesh size 100x100 mm complete all as specified and directed by Engineer - in - Charge. Note:- The weight of chain link fencing shall be ascertained by BOO as directed by GE and payment shall be paid accordingly BOO duly countersigned by GE shall be encloused with final bill. 860 kg
42 42 Fixing only of chain link fencing including line wires, any mesh size and type to any type of satanderds, rails, straining bolts etc including binding wire complete all as specifed and directed by engineer-in-charge. 433 Sqm
43 43 S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and dia of neck 10 mm complete all as specified and directed by Engineer - in - Charge. 33 kg
44 44 M&L for TMT bars 8 to 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia using TMT bars complete all as specified and directed by Engineer - in - Charge. 244 kg
45 45 M & L for mild steel TMT bars 5mm dia and over upto and including 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and directed by Engineer - in - Charge. 20 kg
46 46 S&F factory made steel ventilator with side hung type with glazing bars complete all as specified and directed by Engineer - in - Charge. 0.36 Sqm
47 47 M&L for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete with Powder Coating on aluminium minimum thickness of powder coating 50 micron all as specification the top and bottom horizontal members and vertical members adjacent walls and cills where required and fixing with the help of rawl plug and screw or with fixing clip or with expansion hold plate fasteners. Aluminium section shall be smooth, rust free, straight mitred and jointed mechanically where ever required complete all as specified and directed by Engineer - in - Charge. 10 kg
48 48 M&L for anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised\naluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed by Engineer - in - Charge. 0.54 Sqm
49 49 M&L for Anodised aluminium snap grid 605x605 mm frame work for false ceiling including hangers complete all as specified and directed by Engineer-in-charge. 137 Sqm
50 50 S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long Size of grid 605 x 605mm complete all as specified and directed by Engineer - in - Charge 137 Sqm
51 51 M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge. 20 Sqm
52 52 S&F Prelaminated particle board,19 mm thick interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed by Engineer - in - Charge. 4.2 Sqm
53 53 M & L for 18- 20 mm thick machine cut kota stone slab flooring laid over and including 25 mm thick (min size 55cmx 55cms) screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer - in - Charge. 120 Sqm
54 54 M & L for 18-20 mm thick machine cut kota stone slab as in vertical surfces such as skirting, dados etc, laid over and including 10 mm thick backing coat in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer - in - Charge. 20 Sqm
55 55 M&L for 100 mm thick cement concrete 1:2:4, Type B-2 (40mm graded aggregate) as in flooring laid in alternate bays finished cement concrete surface even and smooth Without using extra cement and Spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified and directed by Engineer - in - Charge. 224 Sqm
56 56 M & L for 50 mm thick cement concrete 1:3:6 type C –2 (40mm graded stone aggregate) as in plinth protection or similar works finished even and smooth with using extra cement etc complete all as specified and directed by Engineer - in - Charge. 9.5 Sqm
57 57 M & L for 75 mm thick cement concrete 1:3:6 type C –2 (40mm graded stone aggregate) as in plinth protection or similar works finished even and smooth with using extra cement etc complete all as specified and directed by Engineer - in - Charge. 7 Sqm
58 58 M&L for 75mm thick cement concrete (1:4:8) type D-2, (40 mm graded stone aggregate) as in sub base, foundation filling and mass concrete complete all as specified and directed by Engineer - in - Charge 295 Sqm
59 59 M&L for 75 mm thick cement concrete 1:2:4, Type B-2 (40mm graded aggregate) as in sub base of flooring finished even and fair complete all as specified and directed by Engineer - in - Charge. 45 Sqm
60 60 M&L for 25 mm thick cement concrete 1:2:4, Type B-0 (12.5mm graded aggregate) as in floor finished even and fair complete all as specified and directed by Engineer - in - Charge. 65 Sqm
61 61 S & F Glass dividing strips, 3 mm thick and width 38 mm inserted in position confirm to design complete all as specified and directed by Engineer-in-Charge. 65 RM
62 62 M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.06 sqm but not exc 0.11 sqm in floor etc, laid over and including 15 mm thick screed bed in CM 1:4 and set and jointed in cement slurry and pointed in white cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer - in - Charge. 9 Sqm
63 63 M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but not exc 0.18 sqm in floor etc, laid over and including 15 mm thick screed bed in CM 1:4 and set and jointed in cement slurry and pointed in white cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer - in - Charge. 5 Sqm
64 64 M&L for glazed ceramic coloured tiles interior grade, of size 450x300x7 mm thick as on vertical surfaces like dados or skirting laid over and including 15mm thick rendering in CM 1:4 and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer - in - Charge. 46 Sqm
65 65 M&L for glazed ceramic coloured tiles interior grade, of size 450x300x7 mm thick as on vertical surfaces like dados or skirting laid over and including 10mm thick rendering in CM 1:4 and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer - in - Charge. 50 Sqm
66 66 M&L for virified ceramic tiles 10mm thick (square / rectangular) area of each tile n. exc 0.36 Sqm in floors etc. laid over and including 15 mm thick screed bed in CM 1:6, set and jointed in cement slurry mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer-in-Charge 75 Sqm
67 67 M&L for virified ceramic tiles 10mm thick (square / rectangular) polished area of each tile n. exc 0.36 Sqm as in skirting, dados laid over and including 10 mm thick screed bed in CM 1:3, set and jointed in cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer-in-Charge 13 Sqm
68 68 M&L for precast coloured rubber moulded concrete machine pressed concrete interlocking paver blocks any shape and size conforming to IS 15658-2006 of 60 mm thickness, M 35 grade wirh grey cement and pigment complete all as specified and directed by Engineer-in-Charge. 90 Sqm
69 69 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises,complete all as specified and directed by Engineer-in-charge. 180 Sqm
70 70 Taking down cement plaster on brick or concreate wall surfaces including racking out joints, hacking for key, scrubbing down with water etc. complete complete all as specified and directed by Engineer-in-Charge. 13 Sqm
71 71 M&L for rendering 15 mm thick in CM 1:4 on brick work or concrete work surfaces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge. 104.5 Sqm
72 72 M&L 15 mm thick rendering in CM 1:6 on face of brick / concrete wall surfaces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge. 80 Sqm
73 73 M&L 5 mm thick rendering in CM 1:3 on ceiling surfces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge. 10 Sqm
74 74 M&L for preparation of new plastered surfaces of walls and applying two coats of cement based paint over a coat of white wash complete all as specified and directed by Engineer - in - Charge. 132 Sqm
75 75 M&L for preparation of new plaster surfaces of walls and applying three coat of white wash complete all as specified and directed by Engineer-in-charge. 30 Sqm
76 76 M&L for preparation of new plaster surfaces of ceiling and applying three coat of white wash complete all as specified and directed by Engineer-in-charge. 10 Sqm
77 77 M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper, over a coat of chalk whiting complete all as specified and directed by Engineer-in-Charge. 10 Sqm
78 78 M&L for preparation of old decorated plastered or un-plastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot,moulds,moss and efflorescent salts and trading oil and greasy spots and applying one coat of oil emulsion distemper complete all as specified and directed by Engineer-in-Charge. 20 Sqm
79 79 M&L for preparation of newly plastered surfaces of walls and applying two coats of dry distemper complete all as specified and directed by Engineer-in-Charge. 12.5 Sqm
80 80 S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc. 0.5 sqm in each pane complete all as specified and directed by Engineer - in - Charge. 0.45 Sqm
81 81 S & F 5.5 mm thick sheet glass, selected quality fixed in door/ shutter /window shutter exc 0.5 sqm in each pane, cut to required size with PVC/Neopane gasket etc complete all as specified and directed by Engineer-in-charge.Note; Aluminium snap beading shall be paid separately. 0.5 Sqm
82 82 M&L for preparation of new wood and wood based surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of Pink primer complete all as specified and directed by Engineer - in - Charge. 5 Sqm
83 83 M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide, zinc chrome primer complete all as specified and directed by Engineer - in - Charge 74 Sqm
84 84 S & F Galvanised steel water tubing 25 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge. 60 RM
85 85 S & F Galvanised steel water tubing 15 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge. 55 RM
86 86 S & F Galvanised steel water tubing 20 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge. 55 RM
87 87 M&L for Cutting existing steel tubing for alterations or additions 40mm or 50 mm size, add if necessarily done in position without taking down complete all as specified and directed by Engineer-in-Charge. 2 Each Job
88 88 S&F rotational moulded white colour polyethylene water storage tank 500 litre capacity (Cylindrical vertical with closed top) hoisted and fixed in position with necessary fittings complete all as specified and directed by Engineer - in - Charge. (Note : PVC tanks shall be ISI marked, having three layres ) 4 Each
89 89 S & F 15mm bib tap cast copper alloy,fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferule complete all as specified and directed by Engineer-in-Charge. 3 Each
90 90 S&F 15mm bore stop cock / valve cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge. 4 Each
91 91 S&F 20mm bore stop cock / valve cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge. 3 Each
92 92 S&F in repair 15 mm bore angle stop valve cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge. 3 Each
93 93 S & F 25 mm bore gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directrd by Engineer in charge. 4 Each
94 94 S & F in repair 20 mm bore gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directrd by Engineer in charge. 1 Each
95 95 S&F 15mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer - in - Charge. 2 Each
96 96 S&F 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed by Engineer - in - Charge. 2 Each
97 97 S&F in repair grating doom 100 mm dia of PTMT complete all as specified and directed by Engineer-in-Charge. Note:- Minimum weight 25gms 3 Each
98 98 S & F towel ring and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 90gms) complete all as specified and directed by Engineer-in-Charge 2 Each
99 99 S&F 100mm dia bore sand cast, cast iron soil, waste and vent pipes in any length with or without ears with cement joints laid in trenches or fixed to wall complete all as specified and directed by Engineer - in - Charge 9 RM
100 100 S&F 75mm dia bore sand cast, cast iron soil, waste and vent pipes in any length with or without ears with cement joints laid in trenches or fixed to wall complete all as specified and directed by Engineer - in - Charge 7 RM
101 101 S&F 75mm bore cast iron Bends (any radius),with duck's foot or heel rest diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge. 4 Each
102 102 S&F PVC connections 15mm size with PTMT nut of length 450mm complete all as specified and directed by Engineer-in-Charge. Make:- Prayag cat part No- BS-115(long) or equivalent cat part as approved by GE 6 Each
103 103 S&F PVC (SWR) floor trap 75mm dia ppipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge. 10 RM
104 104 S&F PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge. 5 Each
105 105 M & L for PCC 1:3:6 type C –2 bed to drain pipes 100 mm including packing under, haunching against the sides of pipes after they are laid and tested complete all as specified and directed by Engineer - in - Charge. 6 RM
106 106 M & L for PCC 1:3:6 type C –2 bed to drain pipes 150 mm including packing under, haunching against the sides of pipes after they are laid and tested complete all as specified and directed by Engineer - in - Charge. 25 RM
107 107 M&L for Salt - glazed stone ware drain pipes 100mm bore laid in trenches and jointed complete all as specified and directed by Engineer - in - Charge 6 RM
108 108 M&L for Salt - glazed stone ware drain pipes 150mm bore laid in trenches and jointed complete all as specified and directed by Engineer - in - Charge 5 RM
109 109 S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engineer - in - Charge 2 Each
110 110 Cutting for 150 mm pipe into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed by Engineer-in-Charge 4 Each
111 111 S&F vitreous china urinal, bowl type (back or corner wall type), complete including providing and fixing plugs bedding urinal against wall in cement mortar 1:2, securing urinals to plug with and including 60mm long brass screws and brackets, 32mm bore LDPE flush pipe of pressure rating 6 Kg/ Cm2 and grating and union for discharge pipe, waste coupling of PTMT minimum weight 45 gm, including urinal spreader of PTMT any colour for fixing with 15 mm dia pipe complete all as specified and directed by Engineer - in - Charge. 2 Each
112 112 S&F vitreous china wash down water closet pan (Pedstal pattern) white excluding flushing cistern & flush pipe but including seat cover complete all as specified and directed by Engineer - in - Charge. 2 Each
113 113 S&F in repair water closet vitreous china squatting pan "Orrisa pattern" size 580mmx440mm white with integral foot rests and CI 'P' trap and proper connecting to flushing cistern complete all as specified and directed by Engineer-in-charge. 1 Each
114 114 S&F 10 litre capacity low level PVC valve less, syphonic action type flushing cistern, white, with inlet, ball valve, float and handle including bracket and provision of flush pipe of polythene of high density or PVC, 32mm dia complete all as specified and directed by Engineer-in-Charge. 3 Each
115 115 S&F vitreous china wash hand basin white, flat back size 550x400mm including brackets, waste coupling 32mm dia of brass Chromium plated, 15mm dia pillar tap of cast copper alloy with capstan head screwed down, high pressure, with or without letter "Hot or Cold" with long screwed shank and fly nuts, 32mm dia, waste pipe low or high density polyethelene of pressure rating 6 Kg/Sqm and PVC connection with PTMT nuts of 15mm dia and 450mm long cutting for and pinning in end of brackets or erecting stand etc. complete all as specified and directed by Engineer - in - Charge. 2 Each
116 116 S&F in repair vitreous china wash hand basin white, flat back size 550x400mm including brackets, waste coupling 32mm dia of brass Chromium plated, 15mm dia pillar tap of cast copper alloy with capstan head screwed down, high pressure, with or without letter "Hot or Cold" with long screwed shank and fly nuts, 32mm dia, waste pipe low or high density polyethelene of pressure rating 6 Kg/Sqm and PVC connection with PTMT nuts of 15mm dia and 450mm long cutting for and pinning in end of brackets or erecting stand etc. complete all as specified and directed by Engineer - in - Charge. 4 Each
117 117 S & F mirror 600 x 450mm size of selected quality glass 5mm thick fixed on 6 mm thick plywood with aluminum frame including key hole plates for hanging and fixed to wall with chromium plated screws complete all as specified and directed by Engineer - in - Charge 6 Each
118 118 S&F soap dish CP brass 100mm dia (round or oval) fixed to walls or dados. complete all as specified and directed by Engineer - in - Charge. 6 Each
119 119 Demoliton of brick work built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed by Engineer - in - Charge. 1 Cum
120 120 Demolition of cement concrete in ground floor and paving n. exc. 15cm thickness (below or above ground level) of any description complete all as specified and directed by Engineer-in-Charge. 31 Cum
121 121 S & F Fiber Glass Reinforced plastic (FRP) Door Frames of required colour of three legged of cross section 90mmx45mm having single rebate of 32mmx45mm having single rebate of 32mmx15mm to receive shutter of 30 mm thickness. The laminate door frame molded with fire retardant grade unsaturate polysterresinn and chopped mat.Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiberglass from all sides, MS stay shall be provided at the bottom to steady the frame complete all as specified and directed by Engineer - in - Charge 4.8 RM
122 122 S & F 30mm thick glass fiber reinforced plastic (FRP) paneled door shutter of required colour and approved brand and manufacture made with fire retardent grade unsaturated polyster resin moulded to 3mm thick FRP laminated for forming hollow rails and style with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5mm thick FRP laminate for panels for conforming to IS:14856-2000 complete all as specified and directed by Engineer - in - Charge. 1.6 Sqm
123 123 Taking down light,fan,socket or power complete including fixture and fittings such as switches& sockets and removing materials for taking credit complete all as specified and directed by Engineer-in-charge. 12 Per point
124 124 M&L for concealed conduit point wiring complete for light /fan with cable 1.5 sqmm(Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC conduit pipe medium grade 20mm bore,pipe hooks,elbows,junction covers and junction boxes, after cutting in wall chasing for conduits and sinking's for sunken cast iron /pressed steel terminal boxes of suitable length and thickness for mounting switches, sockets, fan regulator with 3mm thick plastic laminated seat cover fixed with brass screws and cup washers, duly grouting and painted with red oxide metal primer and making good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth contuity conductor along with point wiring of 1.5 sqmm copper FRLS PVC insulated cable for one light/fan point controlled by one way switch and connected to common earth dolly, complete all as specified and directed by Engr-in-charge. 16 Per point
125 125 Labour only for srl item No 123 existing concealed conduit point wiring complete for light /fan with cable 1.5 sqmm(Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC conduit pipe medium grade 20mm bore,pipe hooks,elbows,junction covers and junction boxes, after cutting in wall chasing for conduits and sinking's for sunken cast iron /pressed steel terminal boxes , one light/fan point controlled by one way switch and connected to common earth dolly, complete all as specified and directed by Engr-in-charge. 12 Per point
126 126 All as described in Srl item No -124 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed by Engineer - in - Charge. 3 Per point
127 127 All as described in Srl item No. 124 here in before but for one socket outlet 3 pin 5/15 Amps on independent board with 2.5 Sqmm (Nominal Area) FRLS PVC insulated multistranded unsheathed copper conductor and continuous earth contuity conductor along with point wiring of 2.5 sqmm copper FRLS PVC insulated copper cable complete all as specified and directed by Engineer - in - Charge. 2 Per point
128 128 Fixing only srl item No 123 Fluorescent tube light fitting, 1x36 w,230v , Box type, epoxy powder coated CRCA sheet housing with reflector cover channel, with electronic ballasts, bipin holders, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size 12 Each
129 129 S & F switch piano flush type 5/6 Amp single pole one way complete all as specified and directed by Engineer - in - Charge 21 Each
130 130 S&F Switch socket combination 2 in 1, 6 pin , 15/16 Amp flush universal type all as spd and directed by Engr in charge. 2 Each
131 131 S & F Socket outlet 5 pin 5 Amps flush type complete all as specified and directed by Engineer - in - Charge. 3 Each
132 132 S & F ceiling rose, surface bakelite 65x50 mm three terminals complete all as specified and directed by Engineer - in - Charge. 9 Each
133 133 S & F extruded aluminium LED batten channel 20 watt having input voltage AC90-300V, 50Hz, 6500K, with white acrylic cover tube light fitting wall mounted complete with rod, driver and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. LUMILINEPLUSBS20WLED865SPCSS, Bajaj cat part No. BCLSBAL 20W CW, Crompton cat part No. CCS-100-20-65-HL2-DP-NWH 4 Each
134 134 S & F angle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer - in - Charge. 3 Each
135 135 S & F LED lamp 9 W for angle holder complete all as specified and directed by Engineer - in - Charge. 2 Each
136 136 S & F water tight bulk head fitting, comprision of connector galvanised cast iron back plate, weather proof enamelled gallery, glass well and including 10 watt LED lamp complete all as specified and directed by Engineer-in-Charge. Make :-Havells cat part No. HEXAFT10WLED857SSYMBOPC, Bajaj cat part No. BIBWP 10W LED, Crompton cat part No. LBHP-10-CDL 4 Each
137 137 S&F compact decorative energy efficient LED mirror light fitting with antiglare diffuser and decorative end caps suitable for 1x10 watt fitting 2 ft version including LED lamp 10 watt complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. LUMILINEPLUSBS10WLED865SPCSS, Bajaj cat part No. BCLSB 10 WH, Crompton cat part No. LDL-10-CDL 2 Each
138 138 S&F Exhaust fan with high speed noiseless motor of size 280 to 300 mm sweep,900 rpm heavy duty by grouting both ends in wall upto required length and making hole of suitable size in wall, making good the existing surface and connecting with ceiling roses with and including flexible cable 3 core copper conductor of size 24/.02 mm of suitable length with frame. louvers, nuts, bolts etc. including making good disturbed complete all asspecified and directed by Engineer - in - Charge. Make- Crompton/Bajaj/Havell's/Orient 3 Each
139 139 S & F sheet metal enclosure for double door DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 4 ways, 240 Volts ISI marked , 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge. 3 Each
140 140 S & F MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge. 4 Each
141 141 S & F MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge. 2 Each
142 142 S & F in replacement sub-main wiring with two single core cables PVC insulated and un-sheathed 1.5 sqmm (Nominal Area) FRLS stranded copper conductor drawn and including steel dia "medium quantity" PVC conduit including 1.5 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surface and white wash or existing colour, necessary junction box and cover including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge. 20 RM
143 143 M & L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth lead 4 mm dia GI earth wire, by means of bolts, nuts check nuts and washers of galvanised iron and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (wieght not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR Part I and connecting to earth test point including taking our unserviceable earthing with all acessories all as specified or indicated including testing on completionall as specified and directed by Engineer - in - Charge. 2 Each
144 144 Supplying, laying and testing in replacement 6 Sqmmx2 core XLPE insulated, heavy duty electric cable with aluminium conductor 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/ laid under roads/paths/ drain/ culverts or passing through pipes complete all as specified and directed by engineer in charge. 50 RM
145 145 M&L for brick protection layer with one brick wide using sub class ‘B’ bricks laid flat across the cable complete all as specified and directed by the Engineer in charge. 500 Each
146 146 Supply & lay GI pipe light grade 20 mm bore for cable crossing in floors complete all as specified and directed by Engineer-in-Charge. 12 RM
147 182 Note : Amount of credit of Rs 0.00 for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.