| 1 | 1.001 | AIR CONDITIONERS | | | |
|---|
| 2 | 2 | M&L for Tracing out leakage from suction line, discharge line, evaporation condenser, filter, capilary tube, indoor unit, outdoor unit, suction / delivery line, joints by removing AC from its original Installed location by suitable method including brazing, welding and filing of gas R-22 /R-32/ R-410A in window/Split type AC Following capacity . Make :- Refron / Mefron\nNote:- Contractor will provide warranty of Refrigerant gas filledby him in case of gase leakages from suction / delivery valve for 3 month. | | | |
|---|
| 3 | 2.1 | 1.5TR | | 180 | Each Job |
|---|
| 4 | 2.2 | 2.0TR | | 130 | Each Job |
|---|
| 5 | 3 | Removing following type of existing unserviceable compressor cut/uncut from window type/Split type AC and S & F new compressor compatible with all AC's Brands in original position including pressure testing welding, respective refrigerant gas charging, brazing & replacement of filter/strainer made of copper capilary tube, complete.\nMake : - Highly / Samsung / Voltas\nNote:- Contractor will provide the warranty of compressor for 6 month . | | | |
|---|
| 6 | 3.1 | 1.5TR | | 26 | Each Job |
|---|
| 7 | 3.2 | 2.0TR | | 26 | Each Job |
|---|
| 8 | 4 | S&F in replacement compressor electrical wiring connection accessories like copper wire, lug, pin etc. complete all as specified and directed. \nMake: Anchor /Polycab /Finolex\n | | 50 | Set |
|---|
| 9 | 5 | S & F in replacement combined starting and running capacitor Casing - Aluminum / Terminal - Lug ( Quadraple Fast On) to be install in air conditioners outdoor unit of capacity 1.5TR / 2.0 TR for compressor and condensor motor of capacity H & C 50mfd, F & C 4/6mfd, +- 5 %, 50 / 60 Hz, 440 V AC caster oil protected, as per existing installed capacity all as directed and specified by engineer in charge. \nMake :- Havells/ Totaline / EPCOS | | 300 | Each |
|---|
| 10 | 6 | S & F in replacement running capacitor Casing - Plastic / Terminal - Lug / copper wire to be install in air conditioners indoor unit of capacity 1.5TR / 2.0 TR for compressor and condensor motor of capacity 3.15 Mfd, +- 5 %, 50 / 60 Hz, 440 V AC caster oil protected all as directed and specified by engineer in charge. \n Make-Havells/ Totaline / EPCOS | | 150 | Each |
|---|
| 11 | 7 | S & F in replacement of fan blade for condensor motor of 1.5/2.0TR window/ split AC made of high class PVC, Push & Screw tight fitting 3 / 4 blade as per site compatible with all AC's Brands in original position all as specified and directed by Engineer- in-charge. \nMake:- Voltas / Hitachi / Totaline | | 30 | Each |
|---|
| 12 | 8 | M & L for Removing of existing unserviceable burnt out condenser motor from split type AC of 1.5/2.0 TR capacity and S & F new condenser motor of capacity upto to 180 Watt, 3 to 6 Pole , 1100 rpm to 1750 rpm as per existing installed on site, single phase 230 V compatible with all AC's Brands in original position including frixing replacement of rubber bush of motor mounting, testing, commissioning complete. \nMake :- Marathon / Cromptron / Voltas / Guangdong welling motor / AHU | | 40 | Each |
|---|
| 13 | 9 | Dismantling blower fan motor of window type AC of 1.5/2.0 TR capacity and supply and fixing new fan motor alongwith fan of existing make and size and refixing in position, connecting and testing on load all as specified and directed by Engineer-in-Charge. \nMake : Marathon/Crompton/Voltas/Guangdong Welling motor/AHU\n | | 2 | Nos |
|---|
| 14 | 10 | M & L for Removing of existing unserviceable / leakage aluminium condenser from out door unit of capacity split type AC of 1.5/2.0 TR capacity and S & F new copper condenser of capacity 1.5/2.0 TR as per existing installed on site, compatible with all AC's Brands in original position including frixing,brazing, cutting, respective refrigerant gas charging all as directed by engineer in charge. \n Make :- Voltas / Carrier/ Loyed | | 20 | Each |
|---|
| 15 | 11 | Supply and connect in replacement PVC insulated and FR PVC Round Sheathed, Copper Conductor (?exible) industrial cable, 1100 Volts, conforming to IS: 694 3 core of size 4 Sqmm of length 3 mtr suitable for 1.5 TR / 2.0 TR AC. \nMake : - Havells / Polycab/ Finolex | | 10 | Each |
|---|
| 16 | 12 | S & F in replacement of electronic circuit (PCB) Original / Assembled (External type) complete including controlling unit i.e. (remote) all as per existing system and suitable for 1.5/2.0 TR capacity split type / window AC compatible with all AC's Brands in original position as per specified and directed by engineer-in-charge. \nMake :- LG / Carrier / Voltas/ Hitachi / Amtrex / Bluestare | | 40 | Each |
|---|
| 17 | 13 | Removing of existing unserviceable burnt out indoor unit blower motor carefully without bracking blower nut / socket mouth from split type AC indoor of 1.5/2.0 TR capacity and S & F new blower motor of capacity 30W to 60 W, any pole, AC/ DC type as per existing installed on site, single phase compatible with all AC's Brands in original position including with replacement of rubber bush of motor mounting, testing, commissioning complete.\n Make :- Cromptron / Voltas / Guangdong welling motor / AHU | | 20 | Each |
|---|
| 18 | 14 | Supply and install in replacement indoor unit of air cooled split unit Air Conditioners electric driven single phase of capacity 1.5 TR indoor unit complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality including respective gas charging, compatible with all AC's Brands all as specified and directed. \n Make:- Godrej /LG / VOLTAS/ HITACHI/SPEED or equivalent | | 7 | Each |
|---|
| 19 | 15 | Supply and install in replacement indoor unit of air cooled split unit Air Conditioners electric driven single phase of capacity 2.0 TR indoor unit complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality including respective gas charging, compatible with all AC's Brands all as specified and directed. \nMake:- Godrej /LG / VOLTAS/ HITACHI/SPEED or equivalent | | 7 | Each |
|---|
| 20 | 16 | S & F in replacement of insulation foam covering of copper tubbing suction line from out door unit to indoor unit with suitable method of split type AC duly covered and tightened complete as directed by EIC | | 150 | Each |
|---|
| 21 | 17 | S & F in replacement of thermostat suitable for 1.5 TR/2.0 TR capacity Window AC. \nMake :- Indofoss or equivalent | | 2 | Each |
|---|
| 22 | 18 | S & F new wall mount outdoor bracket upto 36 \" Heavy duty MS iron stand with nuts bolts suitable for 1.5/2.0 TR split/ Window type AC, Load bearing capacity: upto 50 kg and connected works all as specified and directed by Engr - in- Charge | | 10 | Each |
|---|
| 23 | 19 | S & F metal encosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps 'C' series complete all as specified. \nMake : - Havells / ABB/Indoasian | | 30 | Each |
|---|
| 24 | 20 | M & L for submain wiring with two runs of PVC insulated and unsheathed FR cable 650/1100 Volts grade, conforming to IS-1536-1977 multi - stranded 2 runs of 4 Sqmm single core copper conductor drawn through and including PVC casing and capping and 1 run of 2.5 Sqmm single core multi- stranded coper conductor PVC insulated and unsheathed FR cable 1100 volts grade, ISI markd earth continuity wire complete all as specified and directed (Note:- 2 runs of 4 Sqmm, 01 run of 2.5 Sqmm and 01 run of casing and capping shall be measured as one length). \nMake :- Anchor / polycab /Finolex | | 300 | RM |
|---|
| 25 | 21 | M & L for Fixing / Shifting installation, testing and commissioning of split type AC's electric driven single phase of capacity 1.5 TR/2.0TR including making holes to the excisting wall made of PCC block / Stone masonary to draw cables and pipes to connect the indoor units to the out door units including new copper suction and delivery line of any length as required on site and PVC drain pipe 20 mm dia complete all as specified | | 30 | Job |
|---|
| 26 | 22 | M & L for Fixing/ Shifting installation, testing and commissioning of window type AC's electric driven single phase of capacity 1.5 TR / 2.0 TR including making necessary opening in the existing wall made of PCC block / Stone masonary equal to window AC size and fixing the AC and making the surface good as original and the opening air tight with necessary packing as required including provision of PCC block masnory platform in CM (1:6) with PCC block of (1:5:8) with 15 mm plaster in CM (1:4) for installation of AC's complete all as directed. | | 5 | Job |
|---|
| 27 | 23 | Removing Split / window type AC unit 1.5/2.0 TR capacity from existing positioin and sevicing the same by complete cleaning and removal of the dust from condenser and evaporator by washing castic soda & water by suitable method including cleaning of air filter, supply and replacement of damaged wires with copper wire PVC insulated of same size, tightening of loose wire, nuts, bolts, servicing of condenser motor by oiling, greasing, setting of grills alignment complete including refixing in original position including provision of thermocol for air thighness, testing and commissioning to the entire satisfactioin of Engineer - in- Charge. | | 300 | Each |
|---|
| 28 | 24 | M & L Tracing out leakage from suction line, discharge line, evaporation condenser, filter, capilary tube/Expansion valve, indoor unit, outdoor unit, suction / delivery line, joints by removing AC from its original Installed location by suitable method including brazing, welding and filing of gas R-22 /R-32/ R-410A in Tower/Cassette type AC of 4.0 TR capacity . \nMake :- Refron / Mefron\nNote:- Contractor will provide warranty of Refrigerant gas filled by him in case of gase leakages from suction / delivery valve for 3 month. | | 4 | Each Job |
|---|
| 29 | 25 | Supply and fix in repairs brass service valve of size 3/8\" suitable for split ACs of any capacity.\nMake- Totaline or as per existing and approved by GE.\n\n | | 25 | Each |
|---|
| 30 | 26 | Supply and fix in repairs brass service valve of size 5/8\" suitable for split ACs of any capacity.\nMake- Totaline or as per existing and approved by GE.\n\n\n | | 25 | Each |
|---|
| 31 | 27 | Supply and fix in repair body of outdoor unit of split AC 1.5 TR capacity including all spare parts (excluding compressor) like copper condenser, electronic circuit, fan motor with blade, brass service valve for suction & discharge line,Capiliary tube,capacitors,refrigerant pipe line and inconnection wiring acessories etc complete all as specified and directed by Engineer-in-charge.\nMake:- Godrej /LG / VOLTAS/ HITACHI/SPEED or equivalent | | 3 | Each |
|---|
| 32 | 28 | Supply and fix in repair body of outdoor unit of split AC 2.0 TR capacity including all spare parts (excluding compressor) like copper condenser, electronic circuit, fan motor with blade, brass service valve for suction & discharge line,Capiliary tube,capacitors,refrigerant pipe line and inconnection wiring acessories etc complete all as specified and directed by Engineer-in-charge.\nMake:- Godrej /LG / VOLTAS/ HITACHI/SPEED or equivalent | | 3 | Each |
|---|
| 33 | 29 | WATER COOLERS | | | |
|---|
| 34 | 30 | Tracing out the leakage from suction/ discharge line, condenser and alike by suitable method including brazing, welding, gas charging R-134, R-22 /R-32/ R-410A including replacement of strainer, capilary tube, nut bolts of compressor as required of water cooler 40 / 80 ltr capacity. \nMake :- Refron | | 5 | Each Job |
|---|
| 35 | 31 | Removing of existing unserviceable compressor cut / uncut from water cooler 40/80 ltr capacity including fixing in original position & R-134, R-22 /R-32/ R-410A gas charging and pressure testing, brazing as required and replacement of strainer, capilary tube & cleaning of condenser coil including cutting of rusted portioin & welding replacement of new sheet of existing gauge etc all as directed complete. \nMake :- Godrej / Tecumsha or equivalent | | 5 | Each |
|---|
| 36 | 32 | S & F in replacement thermostat including knob, plate and screw suitable for 40 / 80 ltr capacity storage type water cooler. \nMake : - Indofoss or equivalent | | 3 | Each |
|---|
| 37 | 33 | S & F in replacement push cock, lifting cock 15 mm size as per existing pattern for water cooler.\nMake-as per existing and approved by GE. | | 5 | Each |
|---|
| 38 | 34 | S & F in replacement PVC drain pipe approx 1.5 mtr long 25 mm dia for water cooler complete with clamp screws etc complete to drainout water from water cooler. | | 5 | Each |
|---|
| 39 | 35 | M & L for Removing existing unserviceable condenser motor and S & F in replacement condenser motor 1/30 HP single phase 1350 RPM. \nMake : Crompton / DLE or equivalent | | 5 | Each |
|---|
| 40 | 36 | S & F in replacement running capacitor Casing - Plastic / Terminal - Lug / copper wire to be install in water cooler unit of capacity 40/80 liter for compressor and condensor motor of capacity 10 Mfd, +- 5 %, 50 / 60 Hz, 440 V AC caster oil protected all as directed and specified by engineer in charge. \nMake-Havells/ Totaline / EPCOS | | 15 | Each |
|---|
| 41 | 37 | S&F in replacement open type relay for water cooler of 40/80 ltr capacity. \nMake : - Indofoss / Ranutrol or equivalent | | 5 | Each |
|---|
| 42 | 38 | REFRIGERATORS | | | |
|---|
| 43 | 39 | Tracing out the leakage from suctiion/ discharge line, condenser and alike by suitable method including brazing, welding, gas charging R-134, R-134, R-22 /R-32/ R-410A replacement of strainer, capilary tube, nut bolts, etc as required of compressor of refrigeratiors of capacity 310 Liter. \nMake :- Refron | | 10 | Each Job |
|---|
| 44 | 40 | Removing existing unserviceable compressor from refrigerator capacity 300 -310 ltr and S&F new in original position & charging of gas R-134, R-134, R-22 /R-32/ R-410A, replacement of strainer, capilary tube complete. \nMake :- Godrej / Tecumsha or equivalent | | 5 | Each Job |
|---|
| 45 | 41 | S&F in replacement of starting relay suitable for 300 ltr capacity refrigerator . \nMake : - Indosafe or equivalent | | 10 | Each |
|---|
| 46 | 42 | S&F in replacement thermostat of defrost type for refrigerator. \nMake : - Indosafe or equivalent | | 10 | Each |
|---|
| 47 | 43 | S&F in replacement of open type relay suitable for 300/310 ltr capacity refrigerator.\nMake : - Indosafe or equivalent | | 10 | Each |
|---|
| 48 | 44 | DESERT COOLERS | | | |
|---|
| 49 | 45 | S&F in repascement Hi Quality Submersible electric pump 18W single phase 230 V A/C 50 cycle, inbuild thermal overload protector minimum head 2 mtr suitable for metal/plastic body desert cooler including testing complete. \nMake : - Bajaj/ Khaitan / Voltas/ Crompton | | 250 | Each |
|---|
| 50 | 46 | S&F in repalcement desert cooler electric fan motor upto 110 W capacity 230 V AC, 50 cycle, copper winding single shaft for metal/plastic body desert cooler as on installed on site including necessary modification / extra nut & bolt, testing complete all as directed by engineer in charge. \nMake:- Crompton / Combridge / Hairecom/ Khaitan | | 250 | Each |
|---|
| 51 | 47 | S&F grass pads of approved quality & pattern and size to suit exisitng coolers. | | 200 | Each set of 3 |
|---|
| 52 | 48 | S&F in replacement selector switch three speeds with knob suitable for existing coolers. | | 150 | Each |
|---|
| 53 | 49 | S&F in replacement PVC distributer with PVC flexible pipe appx 1.6 mtr long including nozzels 3 Nos suitable for desert cooler. | | 200 | Each |
|---|
| 54 | 50 | S&F in replacement fan blade (3 or 4 blade) suitable for motor 1/8 HP single phase of desert coolers. | | 250 | Each |
|---|
| 55 | 51 | M & L for complete wiring of desert cooler from fan motor to water pump, capacitor, control switch by 0.1 Sq mm multistraneed copper wire and in replacement for copper cable 2.00 mtr long size 40.0.0076 complete all as specified and directed. | | 100 | Each |
|---|
| 56 | 52 | Supply only plastic body (Excluding fan motor, pump and fan blade) evaporative desert cooler made of high quality engineer plastic 3mm thick having following technical specification. Cooling capacity 15 cubic meter/5500 cubic feet area, air delivery rate 5000 cubic meter/hour, minimum body size (inches) with Trolly 50x25x21, Blade size (inches) type 18” non corrosive, Climatizer, RMP 1350 minimum, speed control 3 speed, Tank capacity (Ltrs) 70, Power Rating (Watts) 230-240 W, Noise Level (db) 71 all as directed by Engineer-in-Charge.\nMake : Bajaj/Symphony/Havells\n | | 10 | Nos |
|---|
| 57 | 53 | Supply and laying of 20mm outer dia CPVC pipes SDR 11 including with all fittings such as bends, elbow, tee, socket, reducers, unions etc as required at site for on walls/ceiling or laying in floors with proper clamping at a distance of 1 meter complete , conneting to over head tank all as specified and directed. \nMake: Astral / Finolex / Supreme | | 50 | RM |
|---|
| 58 | 54 | WATER DISPENSERS | | | |
|---|
| 59 | 55 | Tracing out the leakage from suctiion/ discharge line, condenser and alike by suitable method including brazing, welding, gas charging R-134, R-134, R-22 /R-32/ R-410A replacement of strainer, capilary tube, nut bolts, etc as required of compressor of water dispenser of cooling capacity 2.5 to 3.4 Ltr/Hr and heating capacity 5.0 to 6.0 Ltr/Hr.\nMake :- Refron | | 7 | Each Job |
|---|
| 60 | 56 | Removing existing unserviceable compressor cut/uncut from water dispenser of cooling capacity 2.5 to 3.4 Ltr/Hr and heating capacity 5.0 to 6.0 Ltr/Hr and S & F new compressor compatible with all water dispenser Brands in original position including pressure testing welding, respective refrigerant gas charging, brazing & replacement of filter/strainer made of copper capilary tube, complete all as specified and directed by engineer-in-charge.\nMake : - Hitachi / Samsung / Voltas/Blue star/LG\nNote:- Contractor will provide the warranty of compressor for 6 month . | | 10 | Each |
|---|
| 61 | 57 | M & L for Removing of existing unserviceable / leakage aluminium condenser from water dispenser of 2.5 to 3.4 Ltr/Hr and heating capacity 5.0 to 6.0 Ltr/Hr and S & F new copper condenser as per existing installed on site, compatible with all water dispenser Brands in original position including frixing,brazing, cutting, refrigerant gas charging all as directed by engineer in charge. \nMake :- Voltas / Carrier/ Loyed | | 2 | Each |
|---|
| 62 | 58 | Supply and fix in repair of body of hot and cold water dispenser of cooling capacity 2.5 to 3.4 Ltr/Hr and heating capacity 5.0 to 6.0 Ltr/Hr including all spare parts(excluding compressor) like copper condenser coil, heater and interconnection wiring & piping acessories etc complete all as specified and directed. \nMake-Voltas/Blue star or equivalent | | 8 | Each |
|---|