Military Engineer Services-MES has published Repair/Maintenance Of Summer Appliances And Connected Items In The Area Of Age E/M Under Ge East Delhi Cantt-10 ( Ge/De-74/2020-21 ) Repair/Maintenance Of Summer Appliances And Connected Items In The Area Of Age E/M Under Ge East Delhi Cantt-10. Submission Date for this Tender is 12-02-2021. Air Conditioner Tenders in GE (East) Delhi Cantt-10 Delhi. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 01-Feb-2021 | Amendmets of BOQ | BOQ | 12-02-2021 |
Name of Work : REPAIR/MAINTENANCE OF SUMMER APPLIANCES AND CONNECTED ITEMS IN THE AREA OF AGE E/M UNDER GE EAST DELHI CANTT-10 | |||||
---|---|---|---|---|---|
Sl. No. | Item Code / Make | Quantity | Units | ||
1 | 1 | Taking down unserviceable ceiling/exhaust fan any sweep from the site for repair/replacement and refixing at the same site after cleaning/greasing/oiling. (Note : Rewinding and other item of the fan will be measured and paid separetely) | 4000 | Each | |
2 | 2 | Rewinding of ceiling fan 1200/1400mm with super enamelled copper winding wire of required size duly varnishing including greasing/oiling, replacement of unsv bearing commissioning and testing to the entire satisfaction of Engr-in-Charge, complete all as specified and as directed. | 3400 | Each | |
3 | 3 | Rewinding of exhaust fan/Fresh air/Wall Fan/ Pedastal fan fan of any size and make (225mm to 300mm sweep) with super enamelled copper winding wire of required size duly varnishing including greasing/oiling, replacement of unsv bearing commissioning and testing to the entire satisfaction of Engr-in-Charge, complete all as specified and as directed. | 500 | Each | |
4 | 4 | All as per description of Srl item No. 3 here-in-before but 375mm sweep. | 50 | Each | |
5 | 5 | All as per description of Srl item No. 3 here-in-before but 450mm sweep. | 50 | Each | |
6 | 6 | S&F in replacement ball bearing No 6201/6102 or other size suitable for ceiling/Exhaust fan, complete all as specified and as directed. | 200 | Each | |
7 | 7 | Replacement of motor with PVC blades suitable for any type fresh air/ventilating fan with copper wound motor, complete all as specified and as directed. | 100 | Each | |
8 | 8 | Replacement of motor with GI blade suitable for 225/250/300mm sweep exhaust fan with copper wound motor, complete all as specified and as directed. | 50 | Each | |
9 | 9 | Replacement down rod of size 150 to 300mm long for hanging ceiling fan complete all as specified and as directed. | 200 | Each | |
10 | 10 | Ceiling fan 1200mm sweep, 240 V, DB, 5 star rating, 50 Hz, single phase complete all as specified and as directed. | 400 | Each | |
11 | 11 | Ceiling fan 1400mm sweep, 240 V, DB, 5 star rating, 50 Hz, single phase complete all as specified and as directed. | 100 | Each | |
12 | 12 | Ventilating fan 250 mm sweep plastic body type including self closing louver and making all electric connections complete all as specified and as directed. | 130 | Each | |
13 | 13 | Ventilating fan 200 mm sweep plastic body type including self closing louver and making all electric connections complete all as specified and as directed. | 100 | Each | |
14 | 14 | Exhaust fan 300mm sweep, single phase, DB, 240 volts, metallic body including suitable size self closing louver and making all electric connections complete all as specified and as directed. | 100 | Each | |
15 | 15 | Pedestal fan 450 mm sweep (faratta type) metallic body including and making all electric connections complete all as specified and as directed. | 10 | Each | |
16 | 16 | Wall mounted fan 400 mm sweep metallic body including and making all electric connections complete all as specified and as directed. | 30 | Each | |
17 | 17 | Desert cooler grass suitable for desert coolers of any size and type complete all as specified and as approved by Engr-in-Charge. | 10 | Each Set of Three | |
18 | 18 | Replacement Desert cooler water pump, 240 volts, 50Hz suitable for desert coolers of any size and type, complete all as specified and as directed.\n | 5 | Each | |
19 | 19 | Replacement Desert cooler fan motor, 240 volts, 50Hz suitable for desert coolers of any size and type, complete all as specified and as directed.\n | 5 | Each | |
20 | 20 | Replacement Desert cooler regulator three steps type, 240 volts, 50Hz suitable for desert coolers of any size and type, complete all as specified and as directed.\n | 5 | Each | |
21 | 21 | Replacement Desert cooler fan blades, 240 volts, 50Hz suitable for desert coolers of any size and type, complete all as specified and as directed.\n | 5 | Each | |
22 | 22 | Replacement plastic body capacitor of cap 2.5/3.15 mfd with wire suitable for ceiling fan 1200/1400mm and making connection complete all as specified and as directed. | 3000 | Each | |
23 | 23 | All as per description of Srl item No. 22 here-in-before but of 4.0 mfd capacity. | 50 | Each | |
24 | 24 | Replacement of MS clamps of fan rod including bolts, nuts, washers and split pin etc., suitable for 1200/1400mm sweep ceiling fan, complete all as specified and as directed. | 300 | Each | |
25 | 25 | Replacement of PVC canopy of fan rod suitable of 1200/1400mm sweep fan, complete all as specified and as directed. | 200 | Each | |
26 | 26 | Replacement of twin twisted flexible, PVC insulated, unsheathed, multistranded copper conductor wire of size 24x0.0076, complete all as specified and as directed. | 3000 | RM | |
27 | 27 | Taking down Window/Split Type Air Conditioner of any make, size of 1.5/2 Ton capacity from existing site including provisioning of dismantling all electrical items/connected parts such as relay capacitor, compressors grills etc and spray cleaning by means of electric air blower and water descaling by using acid on both side of cooling coil and condenser cleaning with nylon brush and washing with clean water to ensure proper cleaning before reassembling complete unit and refixing at site including testing and commissioning complete all as specified & as directed at site to the entire satisfaction of GE. Note :- (a) Parts found defective after dismantling of ACs requiring replacement will be measured and paid separately under relevant items described here in after however refilling of refrigerant gas and other parts required for dismantling/reassembling of the ACs will be deemed to be included in the quoted rate. | 15 | Each Job | |
28 | 28 | Replacement of rotary type compressor for window type AC cap 1.5 TR Make and type as per existing compressor making suction pipe and discharge pipe connections with copper welding/brazing making it leak proof. Pressure testing vacuuming and charging of refrigerant, complete all as specified and as directed. | 2 | Each | |
29 | 29 | Replacement of rotary type compressor for Split AC cap 1.5 TR Make- and type as per existing compressor making suction pipe and discharge pipe connections with copper welding/brazing making it leak proof. Pressure testing vacuuming and charging of refrigerant, complete all as specified and as directed. | 2 | Each | |
30 | 30 | Replacement of rotary type compressor for Split AC cap 2 TR make and type as per existing compressor making suction pipe and discharge pipe connections with copper welding/brazing making it leak proof. Pressure testing vacuuming and charging of refrigerant, complete all as specified and as directed. | 2 | Each | |
31 | 31 | Replacement of starting relay SR-1622, complete all as specified and as directed. | 2 | Each | |
32 | 32 | Replacement of starting relay 3 or 4 terminal with connecting leads suitable for any type and make of window air conditioner of 1.5 Ton capacity, complete all as specified and as directed. | 2 | Each | |
33 | 33 | Replacement of 1.5 TR window type AC Kit having (a) Condenser (b) evaporator (c) Condenser motor with blower but without compressor complete all as specified & directed. MAKE : RENUTRAL / GODREJ / WHIRLPOOL/LG/VOLTAS. | 2 | Each | |
34 | 34 | Rectification of leakage in window type/Split AC’s cap 1.5/2 TR by pressure testing making it leak proof by copper welding/brazing vacuming and charging of refrigerant R-22 complete all as specified & directed | 2 | Each | |
35 | 35 | Replacement of front grill suitable for any type and make of window air conditioner 1.5 T R capacity having good aesthetic look good quality as per sample/at site of any make/model approved by GE, complete all as specified and as directed. | 2 | Each | |
36 | 36 | Outdoor unit for split type AC 1.5 TR complete with compressor condenser coil condenser Motor fan etc., complete all as specified and as directed. | 2 | Each | |
37 | 37 | Replacement of double shaft fan motor 1/5 HP Make and type as per existing motor, complete all as specified and as directed. | 2 | Each | |
38 | 38 | Replacement of capacitor Running Cap 36 to 45 Mfd suitable for operating voltage 240 Volt, 50 HZ, complete all as specified and as directed. | 2 | Each | |
39 | 39 | Replacement of capacitor Running Cap 55-60 Mfd suitable for operating voltage 240 Volt, 50 HZ, complete all as specified and as directed. | 2 | Each | |
40 | 40 | Replacement of starting capacitor 80-100 Mfd, complete all as specified and as directed. | 2 | Each | |
41 | 41 | Replacement of starting capacitor 120 Mfd, complete all as specified and as directed. | 2 | Each | |
42 | 42 | Replacement of air filter element for 1.5 ton window type air conditioner of any make and type as per sample, complete all as specified and as directed. | 2 | Each | |
43 | 43 | Replacement of thermostat suitable for any type and make of window Air conditioner 1.5 ton capacity, complete all as specified and as directed. | 2 | Each | |
44 | 44 | Replacement of blower motor 0.5 HP with blower blade assembly complete in all respect for operating voltage 240 volts, 50 HZ and for any type or make of window air conditioner of 1.5/2 ton capacity, complete all as specified and as directed. | 2 | Each | |
45 | 45 | Replacement of swing motor complete in all respect for operating voltage 240 volts 50 HZ and for any type and Make of window /Split type air conditioner of 1.5/2 Ton capacity, complete all as specified and as directed. | 2 | Each | |
46 | 46 | Replacement of blower of blower motor for split type AC 1.5 /2 TR Make and type as per existing motor, complete all as specified and as directed. | 2 | Each | |
47 | 47 | Replacement of blower motor capacitor 6 mfd suitable for operating voltage 240 volt, 50 HZ, complete all as specified and as directed. | 2 | Each | |
48 | 48 | Replacement of gun metal bush suitable for blower motor of any type and make of window type AC of 1.5/2 Ton capacity, complete all as specified and as directed. | 2 | Each | |
49 | 49 | Rewinding for blower fan motor of window / Split type AC 1.5 TR capacity with proper gauge super enammelled of copper wire not less than 300 gm/unit including testing etc., complete all as specified and as directed | 2 | Each | |
50 | 50 | Disconnecting electrical connection and taking down/removing unserviceable single phase voltage stabilizer 4 KVA or 5 KVA capacity of any make and transporting same to MES Yard for annual repair /servicing /cleaning /maintenance. Dismantling the stabilizer segregating unserviceable/wornout parts, carryout repair including replacement of worn out parts, rewinding burnt out transformer as per existing reassembling all components and transporting the same upto its original location, fitting/fixing and testing for effective working complete all as specified and as directed. Note: New spares shall be measured and paid as supply only here-in-after separately. However spare not mentioned in this schedule and required for smooth functioning of stabilizers are deemed to be included in the quoted rate under this item. | 10 | Each Job | |
51 | 51 | Replacement cut off relay for any type of make voltage stabilizer 4/5 KVA of any type and make, complete all as specified and as directed. | 2 | Each | |
52 | 52 | Replacement of electronic (PCB) for circuit plate for voltage stabilizer 4 KVA or 5 KVA capacity of any make and type, complete all as specified and as directed. | 2 | Each | |
53 | 53 | Replacement Volt meter for voltage stabilizer 4 KVA or 5 KVA capacity of any make and type, complete all as specified and as directed. | 2 | Each | |
54 | 54 | Replacement Fuse grip for voltage stabilizer 4 KVA or 5 KVA capacity of any make and type, complete all as specified and as directed. | 2 | Each | |
55 | 55 | Replacement Control transformer for voltage stabilizer 4 KVA or 5 KVA capacity of any make and type, complete all as specified and as directed. | 2 | Each | |
56 | 56 | Low/High Voltage Cut off Switch, complete all as specified and as directed. | 2 | Each | |
57 | 57 | Brass bushes suitable for 3 to 5 KVA voltate stabilizer, complete all as specified and as directed. | 2 | Each | |
58 | 58 | Thimbles for cable connection of size suitable for Voltage Stabilizer 3 to 5 KVA, complete all as specified and as directed. | 20 | Each | |
59 | 59 | Replacement of MCB SP C Curve type, 10 kA, 10 to 32 Amp, with over load and short circuit protection, complete all as specified and as directed. | 40 | Each | |
60 | 60 | Replacement of MCB SPN C Curve type, 10 kA, 32 to 63 Amp, with over load and short circuit protection, complete all as specified and as directed. | 20 | Each | |
61 | 61 | Single pole and netural enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps, ccomplete all as specified and as directed. | 10 | Each | |
62 | 62 | Replacement Voltage stablizer 4KVA Capacity, 240 Volts, 50 HZ, complete all as specified and as directed. | 2 | Each | |
63 | 63 | Taking down old unserviceable point wiring from existing conduit / batten type (light, fan, socket or power point) such as switches, ceiling rose, pendent holder, regulator and socket etc and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, complete all as specified and as directed. | 200 | Per point | |
64 | 64 | Point wiring with 1.5Sqmm (nominal area) FRLS PVC insulated un-sheathed and multistranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers including cutting in chases and FRLS PVC insulated unsheathed 1.5Sqmm copper conductor mulistranded earth wire, connecting to common earth dolly with and including metal flush box of suitable size for fixing switches/sockets etc complete all as specified and as directed for the following:-\n(Note : The cost of Metal boxes and cover plates etc shall be deemed to be included in quoted rate.)\n(a) One light point / fan point controlled by one 1-way switch/ bell push | 100 | Per point | |
65 | 65 | (b) One socket outet point 5 amps on the same board. | 30 | Per point | |
66 | 66 | (c) One socket outet point 5 amps on the independent board. | 50 | Per point | |
67 | 67 | All as per description of Srl item No. 64 here-in-before but with 2.5Sqmm FRLS copper wire with 1.5Sqmm FRLS copper earth wire for 15 Amp power point. | 20 | Per point | |
68 | 68 | Replacement of Switch piano flush type, single pole, one way, 5/6 Amps complete all as specified and as directed. | 180 | Each | |
69 | 69 | Replacement of socket two-in-one, 5 pin, 5/6 Amp universal type complete all as specified and as directed. | 80 | Each | |
70 | 70 | Replacement of switch 16 Amp,single pole one way complete all as specified and as directed. | 20 | Each | |
71 | 71 | Replacement of socket out let 6 pin, two-in-one type with 6 Amp & 16 Amp, flush type complete all as specified and as directed. | 20 | Each | |
72 | 72 | Replacement of submain wiring complete with 2 x 4.0 sqmm (nominal area) FRLS, PVC insulated, unsheathed and multistandard copper conductor cable ISI marked, and 1 x 2.5 sqmm as earth wire in and including PVC conduit of size 20 mm dia, medium grade and conduit fitting such as tees, bends, elbow, reducers etc. complete all as specified and as directed. | 300 | RM | |
73 | 73 | All as per description of srl item No. 72 here-in-before but with 2 run of 6.0 sq mm FRLS copper wire with 4.0 Sqmm FRLS copper cable as earth wire, complete all as specified and as directed. | 100 | RM | |
74 | 74 | Rewinding of motor of shutter door upto 5 HP with super enamelled copper winding wire of required size duly varnishing including greasing/oiling, replacement of unsv bearing, including taking down the motor and refixing after rewinding, commissioning and testing to the entire satisfaction of Engr-in-Charge, complete all as specified and as directed. | 10 | Each | |
75 | 75 | Replacement High pressure monoblock pump with 8 ltr capacity pressure tank, coupled with electric motor of capacity 0.50 HP, 230 volts, single phase, 50 Hz incl connecting accessories of GI i.e bend, nipple, socket, tee of requisite size etc incl cutting of existing pipe, complete all as specified and as directed. | 6 | Each | |
76 | 76 | Replacement High pressure booster pump with 24 ltr capacity pressure tank, coupled with electric motor of capacity 1 HP, 230 volts, single phase, 50 Hz incl connecting accessories of GI i.e bend, nipple, socket, tee of requisite size etc incl cutting of existing pipe, complete all as specified and as directed. | 1 | Each | |
77 | 77 | Replacement electric motor of capacity 0.50 HP, 230 volts, single phase, 50 Hz for booster pump, complete all as specified and as directed. | 10 | Each | |
78 | 78 | Replacement electric motor of capacity 1 HP, 230 volts, single phase, 50 Hz for booster pump, complete all as specified and as directed. | 2 | Each | |
79 | 79 | Replacement Cylinder 8 ltr capacity for booster pump, complete all as specified and as directed. | 10 | Each | |
80 | 80 | Replacement Cylinder 24 ltr capacity for booster pump, complete all as specified and as directed. | 2 | Each | |
81 | 81 | Replacement pressure guage dial type for booster pump 0.5/1 HP, complete all as specified and as directed. | 5 | Each | |
82 | 82 | Replacement of relay for booster pump 0.5/1 HP, complete all as specified and as directed. | 5 | Each | |
83 | 83 | NOTE :- For minimum fair wages ,EPF and payment to labour employed, refer Sch A Note No-16,17 and Special Condition 22 of this tender. Contractor must produce all the relevent record such as payment made to labour, EPF etc at the time of payment of RARs/Final bill. No payment will be released to contrator without producing the proper record. \n |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy