Provision Of Electric And Water Supply For Certain Bldg And Certain Minor Work At Lailapur And Vairengte Under Ge Silchar, LAILAPUR AND VAIRENGTE-Mizoram

Military Engineer Services-MES has published Provision Of Electric And Water Supply For Certain Bldg And Certain Minor Work At Lailapur And Vairengte Under Ge Silchar. Submission Date for this Tender is 06-02-2021. Electrification Work Tenders in LAILAPUR AND VAIRENGTE Mizoram. Bidders can get complete Tender details and download the document.




Tender Notice

26685090
Corrigendum : Provision Of Electric And Water Supply For Certain Bldg And Certain Minor Work At Lailapur And Vairengte Under Ge Silchar
Open Tender
Indian
Mizoram
LAILAPUR AND VAIRENGTE
06-02-2021

Tender Details

Provision Of Electric And Water Supply For Certain Bldg And Certain Minor Work At Lailapur And Vairengte Under Ge Silchar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Jan-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-02-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 56800.0 /-
Tender Value
Refer document

BOQ Items

PROVISION OF ELECTRIC AND WATER SUPPLY FOR CERTAIN BLDG AND CERTAIN MINOR WORK AT LAILAPUR AND VAIRENGTE UNDER GE SILCHAR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavating in trenches, not exc. 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, not exc. 10 sqm on plan and not exc. 1.5 m in depth and getting out soft / loose soil complete all as specified and directed. 124.17 CUM
2 2 Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. 76.79 CUM
3 3 Removing excavated material not exc. 50 m and depositing where directed ar a level not exc. 1.5 m above starting point complete all as specified and directed. 47.38 CUM
4 4 Supply and spread sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed.\nNote : Thickness of sand cushion after punning down will be measured and paid. 36.18 CUM
5 5 Material and labour for laying of bricks locally available sub-class 'B' brick (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the directon of cable complete all as specified and directed. 3040 EACH
6 6 Taking up and down steel tubing 100mm bore and connections, including cleaning for refixing or removal to store bore of pipes complete all as specified and directed. 12 RM
7 7 Relaying old steel tubing 100 mm bore obtained from taking down items above after cleaning of all silt, dirt, mud, scales etc and connections in new or old position in trenches, walls or floors including new fittings and welding as required complete all as specified and directed. 12 RM
8 8 M&L Steel Tubes, 'Medium grade', 100 mm bore galvanised, with all fittings (i.e bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs, unions, flange etc) incl welding laid in trenches complete all as specified and directed. 18 RM
9 9 All as per item No 08 but of size 80 mm bore 218 RM
10 10 All as per item No 08 but of size 50 mm bore 50 RM
11 11 All as per item No 08 but of size 40 mm bore 10 RM
12 12 All as per item No 08 but of size 25 mm bore 80 RM
13 13 Supply & laying GI Tubes, 'light grade', galvanised, with all fitting; laid in trenches of 40mm dia complete all as specified and directed. 10 RM
14 14 All as per item No 13 but of size 80 mm bore 6 RM
15 15 Cutting of existing 100 mm bore steel tubing and including inserting 100x100x1000mm steel Tee for alterations or additions (Each cut measured) complete all as specified and directed. 2 EACH\nJOB
16 16 Supply, installing and testing of cast iron sluice valve, class PN 1.6, ISI marked conforming to IS-14846 complete suitable for 100 bore pipe with flanged ends duly drilled, brass spindle, CI gate with brass rings and iron wheel head complete all as specified and directed. 3 EACH
17 17 All as per item No 16 but of 80 mm bore 2 EACH
18 18 S & F Gun metal globe or gate valves with iron wheel, head, screwed both ends for iron pipe and fixed for 50 mm bore pipe complete all as specified and directed. 1 EACH
19 19 All as per item No 18 but of 25 mm bore 6 EACH
20 20 S&F PTMT ball valves, high pressure, with polythene float Valves 25mm bore for GI pipes and all connected accessories including dismantling unserviceable valve complete all as specified and directed. 8 EACH
21 21 Supply, instalation and testing Cast iron float valve equiibrium ball type complete suitable for 80 bore pipe with flanged ends duly drilled complete all as specified and directed. 1 EACH
22 22 Supply, instalation and testing of prefabricated SMC(i.e. Sheet mounding compound) panel clean water tank of size 3.0x3.0x2.5mtr (i.e. 22.5 KL max capacity) conforming IS 14399 (Part-1) top covered with manhole for maintenance having prosperities as low\nmaintenance, excellent thermal and hygienic\nproperties, zero light penetration, stable thermal transition, and hygienic quality make incl Corner iron angle size 75mm x 10mm and MS grillage for foundation and fixing of inlet, outlet pipe and connected accessories complete all as specified and directed. 2 EACH\nJOB
23 23 M & L for construction of PCC hard standing/foundation for SMC tank of 22.5 KL of size 3.60 X 3.60 Mtrs incl following complete\nall as specified and directed:-\n(a) Surface excavation and leveling approx 3.6 x 3.6 x 0.2 mtrs after site clearance incl removal of soil.\n(b) Hardcore over excavated area (i.e. 3.6 x 3.6\nMtrs) of broken stone or boulders of size not exceeding 63mm deposited spread and leveled in layers not exceeding 150mm thick watered and rammed to true surface.\n(c) Subfloor over hardcore area (i.e. 3.6 x 3.6 Mtrs) of PCC 1:3:6 type C2 using 40mm graded\naggregates in layers 100mm thick.\n(d) Hardstanding over Subfloor area (i.e. 3.6 x 3.6 Mtrs) of PCC 1:1.5:3 type A1 using 20mm graded aggregates in layers 100mm thick and finishing surface even and smooth without using extra cement. 2 EACH\nJOB
24 24 Material and labour for construction of valve pit chamber of size 600x600x600mm out of Brick work and PCC work including excavation, fabrication chamber cover wirh 3.15mm thick MS plate and 50x50x6mm angle iron frame and painting of chamber cover with two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. 3 EACH\nJOB
25 25 M & L for Water level indicator for SMC tank of 22.5 KL Capacity made-up of with the following : -\n(a) Angle iron ISA 40 x 40 x 4mm thick of length\napprox 7 mtrs.\n(b) MS plate 3mm thick 10 cm wide approx 3 Sqm.\n(c) 15mtrs approx Nylon rope of minimum 5mm dia with MS pulley.\n(d) 1 x PVC float ball 150mm dia.\n(e) foundation for water level indicator of PCC 1:3:6 20mm grade aggregate approx 0.5cum.\n(f) Painting two coats of black paint over a coat of red oxide and marking the water level with white colour as per the tank capacity all as directed by Engr-in-charge.\n(g) Arrow shaped weight marker for water level\nindicator fabricated from 100x10mm thick MS flat of length 100 mm duly painted with two coats of white colour synthetic enamel paint over a top of red oxide primer.\nNote : \n(i) The quoted rate shall be inclusive of all above materials, welding and cutting requested to fabrication the water level indicator.\n(ii) Accuracy of Water level indicator should be in between +/- 2%. \n\n 2 EACH\nJOB
26 26 Supply, Instalation, testing and commisioning outdoor type LT feeder piller box of 0.90x0.90x0.60 mtr minimum size manufactured by CPRI approved firm cubical floor mounted type factory made totally enclosed, dust ad vermin proof made out of 3.15 mm thick MS sheet duly painted with powder coated both side in and out, having proper locking arrangment in both front and rear side aluminium bus bar not less than 250 amps rating duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase, 4 wire, 500 volts, 50 HZ AC supply, hibling , cable entry boxes, cable gland incl iron angle frame (bottom portion of the panel), grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I with the following:-\nIncoming \n(a) On load change over switch 4 Pole, 200A -01 No\n(b) MCCB 200 Amps, 4 polw, 36 KA, 415V - 01 No\nOutgoing\n(a) MCCB 125 Amps, 4 Pole, 36 KA, 415V - 01 No\n(b) MCCB 40 Amps, 4 Pole, 36 KA, 415V - 01 No\n(c) MCCB 32 Amps, 4 Pole, 36 KA, 415V - 02 Nos\n(d) MCB 32 Amps, SPN, 10KA, 415V - 03 Nos\n(e) Digital multi function meter - 01 No\n(f) Phase indicator lamps (RYB) set of 3 - 01 set\nNote : \n(a) Excavation for grounding and PCC foundation for LT Panel shall be deemed incl in quated rate.\n\n(b) Extra space be left on panel's dinrail for mounting one 4 pole MCCB and One TPN MCB and extra space cover with blank plate. 1 EACH JOB
27 27 M&L for 15mm thick rendering in CM 1:4 on brick or concrete surfaces finished even and fair complete all as specified and directed. 7 SQM
28 28 M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm bore GI pipe medium grade for watering, 40 mm bore GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. 3 EACH SET
29 29 Material and labour for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth lead wire 4 mm dia by means of galvanized iron or steel bolts, nuts, check nuts and washers, and connected to equipments as directed, including funnel with GI medium grade watering pipe 20 mm bore &15 mm bore GI light grade protection pipe , wire mesh, charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C1, 50 mm thick pre cast RCC 1:2:4 type B1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance not exceeding 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES Schedule 2009, Part-I complete all as specified and directed. 1 EACH SET
30 30 M & L disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green ,'Two-in-series' assembly for tension with tension clamps for conductors working pressure 11000 volts complete all as specified and directed. 3 EACH
31 31 M&L Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 KA suitable for 11000 Volts grade complete all as specified and directed. \n 1 EACH
32 32 Supply and Laying or passing throught pipe XLPE/PVC sheathed, armored LT electric power Cable (heavy duty) with stranded aluminium conductor of size 120 Sqmm, 3.5 core 1100Volt grade laid throught duct /pipe / trench etc incl cable gland and lugs complete all as specified and directed. 230 RM
33 33 All as per item No 32 but of of size 50 Sqmm, 3.5 core 70 RM
34 34 All as per item No 32 but of of size 16 Sqmm, 4 core 90 RM
35 35 All as per item No 32 but of of size 10 Sqmm, 2 core 100 RM
36 36 Supply and Laying 50mm bore GI tubing light grade with all fitting for passing of cable under road, on wall or on pole with and incl clams, nuts, bolts etc incl taking down old unserviceable GI tubing od any size incl cutting, chases to wall/ floor and making good surface complete all as specified and directed. 12 RM
37 37 Supply and fix MCCB 200 Amps, 4 pole, 36 KA, 415V, Ics = 100% of Icu, in existing panel and making all connections complete all as specified and directed. 1 EACH
38 38 Supply, instalation, testing and commissioning of centrifugal mono-block pump set, electrically driven 2 phase, 230 volts, RPM-3000, 'B' class insulation, IP 44 protection, CI impeller, Sealing - Gland Packing, with discharge capacity of not less than 10 LPS at minimum head 10 mtr, suction and delivery size 80x80 mm, including base frame made of MS Channel 75mm x 50mm x 6mm, with required nuts and bolts and electrical connection from starter to pump set with and including copper wire 4 Sqmm x 3 Core protected with PVC flexible pipe of required length complete all as specified and directed. \nNote:- All accessories required such as clamps, nuts bolt, welding work, wire lugs etc deemed to be included in the quoted rate.\n 2 EACH\nJOB
39 39 Supply and fix Single Phase Starters Sheet steel enclosures of 2HP mono block pump with IP 54 protection,Wide range of relay settings and coil voltages and Standardized accessories and spares available complete all as specified and as directed. 2 EACH
40 40 Supply and Fix P.V.C. insulated unsheathed bright annealed bare copper conductor industrial cables and PVC insulated, PVC round sheathed multicore industrial Cables for voltage grade upto 1100 V. as per IS 694:1990. of size 6 Sqmm 2 Core complete all as specified and as directed. 18 RM
41 41 Supply and Fix P.V.C. insulated unsheathed bright annealed bare copper conductor industrial cables and PVC insulated, PVC round sheathed multicore industrial Cables for voltage grade upto 1100 V. as per IS 694:1990. of size 4 Sqmm 3 Core complete all as specified and as directed. 10 RM
42 42 M & L for Providing precast cement concrete solid building block over 10cm in width and setting in mortar 1:6 using pre cast cement concrete Block 1:3:6 type C1 using 20mm graded stone agg complete all as specified and directed. 2.8 CUM
43 43 M & L for cement concrete 1:4:8 type D aggregate) as in foundation , filling and mass concrete complete all as specified and directed. 2.28 CUM
44 44 M & L PCC 1:3:6 type C-2 (using 20 mm graded crushed stone aggregate ) as in coping including weathering, slightly rounded or chamfered angles and throating , as directed and necessary from work complete all as specified and directed. 1.1 CUM
45 45 Disconnecting electrical HT/LT cable, earth strip connections connected with Transformer and shifting to pump house No. 4 of any type, make and capacity and installed at the pump house no.4 on four pole structure and complete connection of the HT/LT cable,earth strip and connected accessories , commissioning and testing complete and existing transformer shifted to power house store complete all as specified and directed.\nNote- The rate shall deemed to be included for providing all arrangement for carefully handling/conveyance and trasportation of equipment by by means of crane/ chain pully block/ recovery van and vehicles as per requirement and directed by Engr- in-Charge. 1 EACH JOB
46 46 Dismantling and errect steel poles/struts of any size complete all as specified and directed. 2 EACH
47 47 Material and labour for steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP- 31 (9m long)confirming to IS-2713 (Part I & II) incl painting of pole with two coats of aluminium paint over a coat of red oxide zink chrome primer from top of the pole to 1.5m above the bottom of the pole and painting with two coats of black bituminous paint over a coat of red oxide zink chrome primer upto 1.5m from bottom of the pole incl numbering of poles complete all as specified and directed.\nNote : Excavation /earth & PCC work shall be measured and paid separately under respective items. 1 EACH JOB
48 48 Material and labour for cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primercomplete all as specified and directed. 0.4 QTL
49 49 M&L Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed. 2 EACH
50 50 M&L Earth continuity conductor or main earthing lead galvanised iron strip 25 x 4mm with porcelain insulator saddles not exeeding 400 mm spacing and fixing screws to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe/duct or fixed to poles or any other indicated structures complete all as specified and directed. 15 RM
51 51 M & L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 70 to 95 sqmm complete all as specified and directed. 1 EACH
52 52 Supply, Instalation, testing and commissioning of CPRI approved outdoor type LT feeder pillar box of 0.90x0.90x0.60 Mtr minimum size manufactured by CPRI approved firm cubical floor mounted type factory made totally enclosed, dust ad vermin proof made out of 3.15 mm thick MS sheet duly painted with powder coated both side in and out, having proper locking arrangement in both front and rear side aluminium bus bar not less than 250 amps rating duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase, 4 wire, 500 volts, 50 HZ AC supply, hibling , cable entry boxes, cable gland incl iron angle frame (bottom portion of the panel), grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I with the following:-\nIncoming :\n(a) On-load Changeover switch, 4 pole, 200A - 01 No \n(b) MCCB 200 Amps, 4 pole, 36 KA, 415V - 01 No\nOutgoing : \n(a) MCCB 100 Amps, 4 pole, 36 KA, 415V - 02 Nos\n(b) MCCB 63 Amps, 4 pole, 36 KA, 415V - 02 Nos\n(c) MCB TPN 63 Amps 10KA - 04 Nos\n(d) Digital multi function meter - 01 No\n(e) Phase indicator lamps (RYB) set of 3 - 01 Set\nNote : (i) Excavation for grounding and PCC foundation for LT Panel shall be deemed included in quoted rate.\n(ii) Extra space be left on panel's dinrail for mounting one 4 pole MCCB and One TPN MCB and extra space cover with blank plate.\n 1 EACH JOB
53 53 Supply, Instalation, testing and commissioning of CPRI approved outdoor type LT feeder pillar box of 0.90x0.90x0.60 Mtr minimum size manufactured by CPRI approved firm cubical floor mounted type factory made totally enclosed, dust ad vermin proof made out of 3.15 mm thick MS sheet duly painted with powder coated both side in and out, having proper locking arrangement in both front and rear side aluminium bus bar not less than 300 amps rating duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase, 4 wire, 500 volts, 50 HZ AC supply, hibling , cable entry boxes, cable gland incl iron angle frame (bottom portion of the panel), grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I with the following:-\nIncoming :\n(a) MCCB 250 Amps, 4 pole, 36 KA, 415V - 01 No\nOutgoing : \n(a) MCCB 200 Amps, 4 pole, 36 KA, 415V - 01 No\n(b) MCCB 100 Amps, 4 pole, 36 KA, 415V - 01 No\n(c) MCCB 63 Amps, 4 pole, 36 KA, 415V - 01 No\n(d) MCB TPN 63 Amps 10KA - 04 Nos\n(e) Digital multi function meter - 01 No\n(f) Phase indicator lamps (RYB) set of 3 - 01 Set\nNote : \n(a) Excavation for grounding and PCC foundation for LT Panel shall be deemed included in quoted rate.\n(b) Extra space be left on panel's dinrail for mounting one 4 pole MCCB and One TPN MCB and extra space cover with blank plate.\n 1 EACH JOB
54 54 Supply, Instalation, testing and commissioning of CPRI approved outdoor type LT feeder pillar box (i.e. Bus Bar Box) of 0.60x0.60x0.45 Mtr minimum size manufactured by CPRI approved firm cubical floor mounted type factory made totally enclosed, dust ad vermin proof made out of 3.15 mm thick MS sheet duly painted with powder coated both side in and out, having proper locking arrangement in both front and rear side aluminium bus bar not less than 200 amps rating duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase, 4 wire, 500 volts, 50 HZ AC supply, hibling , cable entry boxes, cable gland incl iron angle frame (bottom portion of the panel), grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I all as specified and directed. \nNote: Excavation for grounding and PCC foundation for LT Panel shall be deemed included in quoted rate.\n 1 EACH
55 55 Supply and instalation of hi wall split AC with hot and cold operation, quickly and efficiently circulate cool air in summers and hot air in winter indoor/outdoor complete with cord less remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TR complete all as specified and directed. Make Cat No. 18H SZS of voltas or equivalent to LG /Samsung/ Vediocon / Godrej/ Whirlpool/ Blue Star 1 EACH
56 56 Supplyand instalation voltage stablizer for automatic operation,single phasenaturally air cooled indoor type and designed for input variation betwwen 170 V to 250 V with output voltage stabilized at 230 v complete all as specified and directed. \n 1 EACH
57 57 Material and labour for Sub main wiring with approved colour coding as per IS with four single core PVC insulated cable FRLS with stranded copper conductor of size 6 Sq. mm nominal area and drawing into PVC non metallic rigid PVC casing including one run of PVC insulated with 6.0 Sqmm (nominal area) FRLS stranded copper conductor as earth wire complete all as specified and as directed.\nNote:- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of PVC casing caping will be measured as one unit. 30 RM
58 58 Supply and fixing in metal plug socket single pole and neutral enclosure with two pin earth plug with 1 No MCB SP 20 Amp 'C' series Complete all as specified and as directed. 1 EACH