Provision Of Water Proofing Treatment Of Otm Accommodation And Improvement To Officers Mess And Certain Major Revenue , Lbw And Minor Works At Af Stn Kanheri Hills Under Ge ( Af ) Thane, THANE-Maharashtra

Military Engineer Services-MES has published Provision Of Water Proofing Treatment Of Otm Accommodation And Improvement To Officers Mess And Certain Major Revenue , Lbw And Minor Works At Af Stn Kanheri Hills Under Ge ( Af ) Thane. Submission Date for this Tender is 06-02-2021. Water Proofing Work Tenders in THANE Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

26654653
Corrigendum : Provision Of Water Proofing Treatment Of Otm Accommodation And Improvement To Officers Mess And Certain Major Revenue , Lbw And Minor Works At Af Stn Kanheri Hills Under Ge ( Af ) Thane
Open Tender
Indian
Maharashtra
THANE
06-02-2021

Tender Details

Provision Of Water Proofing Treatment Of Otm Accommodation And Improvement To Officers Mess And Certain Major Revenue , Lbw And Minor Works At Af Stn Kanheri Hills Under Ge ( Af ) Thane

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Jan-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-02-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 62000.0 /-
Tender Value
INR 31 Lakhs /-

BOQ Items

Name of Work: PROVN OF WATER PROOFING TREATMENT OF OTM ACCOMMODATION AND IMPROVEMENT TO OFFICER'S MESS AND CERTAIN MAJOR REVENUE ,LBW AND MINOR WORKS AT AF STN KANHERI HILLS UNDER GE (AF) THANE
Sl. No. Item Description Unnamed: 2 Quantity Units
1 1.01 Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out all as specified. 80.5 Sqm
2 2 Excavation in trenches not exceeding 1.5 mtr wide and n exe 1.5 mtr in depth for foundation for shafts well etc not exceeding 10 Sqm on plan and getting out in hard /dense soil. complete all as specified and directed by Engr-in-Charge. 37.125 Cum
3 3 Returning, filling in including spreading, levelling watering and well ramming in leyers n.exc 25cm each layer in soil complete all as specified and directed by Engr-in-Charge. 6.75 Cum
4 4 Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, in brick wall complete all as specified and directed. 44 Each
5 5 M&L for Sand filling under floors including watering & consolidation 1.5 cum
6 6 Removing excavated material n exc. 50m and upto a total distance of 250 m.depositing where directed at a level n exc. 1.5 m above the starting point 40.1 Cum
7 7 M&L for Hardcore of gauge n exc. 63mm,Broken stone or boulders deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. 22.425 Cum
8 8 Material, labour and injecting chemical emulsion for Post Constructional\nAntitermite Treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including\ndrilling and plugging holes etc. complete all as specified and directed 700 RM
9 9 Material, labour and injecting chemical emulsion for Post Constructional\nAntitermite Treatment along the internal wall masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed 950 Sqm
10 10 Material, labour and injecting chemical emulsion for Post Constructional\nAntitermite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to\ncentre and sealing the same complete all as specified and directed. 365 RM
11 11 M&L PCC 1:2:4 type B2 using 40 mm graded aggregate as in foundation complete all as specified and directed. 5.06 Cum
12 12 M&L for PCC (1:4:8) type D-2 using 40mm stone agg as in foundations, filling & mass concrete complete all as specified and directed by Engr-in-Charge. 6.75 Cum
13 13 M&L for Cement concrete Type B-2, 1:2:4 using 40 mm graded aggregate in surface channels and drains, complete all as specified & as directed. 1.125 Cum
14 14 M&L for providing cement concrete in mud stops rounded or chamfered on edges ( as at edge/end of interlocking paver block) 0.6 Cum
15 15 M&L for Cement concrete Type C-1, 1:3:6 using 20 mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified & as directed. 3.6 Cum
16 16 Material and labour for providing plain cement concrete type B- 1, (1:2:4) using 20mm graded stone aggregate as in roof padding laid in slope as per requirement mixed with integral water proofing liquid admixture as per manufacturer's instructions complete all as specified and as directed.\nNote : (i) Minimum thickness of PCC shall be 50mm. \n (ii) Integral water proofing liquid admixture shall be measured and paid separately under appropriate item here in after\n\n 50 Cum
17 17 M&L for Pre-cast cement concrete block masonry 1:3:6 Type C-1 (using 20mm graded aggregate)with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete complete all as specified and directed by Engr in Charge 14.328 Cum
18 18 Material & labour for providing reinforced cement concrete (1:1½: 3) type A0 (using 12.5mm graded stone aggregate) mixed with integral water proofing liquid admixture CONPLAST X421IC (Fosroc) or equivalent as per manufactures instructions as in columns, pillars,lintel, slab supported walls roof, landings, balconises, canopies, deck slabs and in shelves etc complete all as specified & as directed. 1.5 Cum
19 19 Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc (Inner girth only measured) complete all as specified and directed by Engr-in-Charge. 75 RM
20 20 Supply only integral water proofing compound. 7.74 Kg
21 21 Cutting holes into or through brick walls built in lime mortar and stone walls built in mud mortar and making good in cement mortar 1:3 or cement\nconcrete 1:2:4 type B-l as required Superficial Area N.Exc 150 Sqcm complete all as directed. 300 Per CM Depth
22 22 S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut 5 cm but n.exc 10 cm long, 11 to 15mm complete all as specified and directed. 29 KG
23 23 S&FJoist, channel, angle, or tee sections, (Fe-410-W(Gde-E-250) quality- B) fixed independently, without connection plate, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) 350 KG
24 24 S&F Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment including fabrication and errection 55 KG
25 25 M&L framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings using Fe-410- W(Gde- E-250) quality-B including one coat of primer complete all as specified 20 KG
26 26 S&F steel work as in tubular (round/square/ rectangular shape of pipes as approved by Engr-in-Charge) trusses upto height 3 mtr including post special shaped washers etc complete incl necessary nut bolts wind tiles and gusset plates etc using ERW or induction butt welded tubes conforming to IS 1161-1998 grade Yst-240 all as specified and directed. 1708.5 KG
27 27 M&L for steel door including projecting type hinges, steel handle, complete, with glazing bars, dovetailed or welded including one coat of primer complete all as specified 3.15 Sqm
28 28 Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. 166 Sqm
29 29 M&L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3, for inserting the roof sheet in to the wall and making good with existing wall colour all as specified and directed 10 RM
30 30 M&L for cement concrete type D-2, 1:4:8 (40 mm graded aggregate) 75 mm thick 30 Sqm
31 31 M&L for 50mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in finishing surfaces of concrete, finish topping even and\nfair (without using extra cement), complete all as specified and directed. 58.5 Sqm
32 32 M&L for 75mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub-base, finish even and rough to receive the topping layer, complete all as specified and directed. 139 Sqm
33 33 M&L for machine pressed precast coloured concrete interlocking paver block with lacquer finish any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade with grey cement & pigment. 30 Sqm
34 34 M&L for glazed coloured ceramic tiles glossy finish of size 300 x 450 mm x 7mm thick on vertical surfaces such as skirtings dados set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed by Engr in Charge 7.2 Sqm
35 35 M&L Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match dark shade all as specified and directed by Engr in Charge 8 Sqm
36 36 M&L for machine pressed precast chequered concrete coloured tiles lacquer (a hard glossy coating) finish of size 300 X 300 mm confirming to IS 15658-2006 of 25 mm thickness, M-35 grade set, jointed and pointed in neat cement slurry in floors finish and with grey cement & pigment. 165 Sqm
37 37 Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to stone and rubbish of the premises. 158.2 Sqm
38 38 M&L for rendering 10mm thick in CM 1:4 as backing coat to receive dado finished all as specified and directed by Engr in Charge 7.2 Sqm
39 39 M & L for rendering 20 mm thick in cement mortar 1:4 (15 mm thick backing coat and 5mm thick finishing coat) on fair faces of brick work or concrete surfaces including finished even and smooth without using extra cement with using water proofing compound (water proofing compound shall be measured and paid seperately) 140 Sqm
40 40 M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 mixed with water proofing compound including finished even and smooth without using extra cement complete all as specified. Note: Water proofing compound will be measured and paid seperately. 116.7 Sqm
41 41 M&L for 15mm thick screed bed in CM 1:6 for receiving floor finished all as specified and directed by Engr in Charge 173 Sqm
42 42 Taking down cement plaster any description etc incl racking out joints, hacking for key scrubbing down with water etc complete all as specified. 140 Sqm
43 43 M&L for preparing New plastered surfaces, priming plastered surface with Chalk Whiting and applying two coats of White wash on walls 58.35 Sqm
44 44 M&L for applying two coat of synthetic enamel paint over primed steel surfaces of any description over 10 cm in width or girth not otherwise described and complete all as specified and directed 6.3 Sqm
45 45 M&L preparation of new or previously untreated surface & applying two coat synthetic enamel Painting over a coat of preiming red red oxide zinc chrome complete all as specified and directed. 215 Sqm
46 46 S&F for 20 mm bore medium grade GI tubing with all fittings fixed to walls and ceiling or laid in floors complete all as specified and directed. (Work includes with screwed socket joints, together with all tube fillings such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc. and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches, etc., also for cutting, screwing and waste and for making forged bends on piping as required. Connectors shall be inserted, where required or directed. The rates also include cutting through walls, floors, etc. and their making good.) 80 RM
47 47 S&F for 25 mm bore medium grade GI tubing with all fittings fixed to walls and ceiling or laid in floorscomplete all as specified and directed. (Work includes with screwed socket joints, together with all tube fillings such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc. and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches, etc., also for cutting, screwing and waste and for making forged bends on piping as required. Connectors shall be inserted, where required or directed. The rates also include cutting through walls, floors, etc. and their making good.) 565 RM
48 48 Taking up or down steel tubing and connections of 20mm bore of pipe and removing to store as in roof /walls, etc.. all as specified and directed by Engr-in-Charge. 80 RM
49 49 Taking up or down steel tubing and connections of 25 OR 32 mm bore of pipe and removing to store as in roof /walls, etc.. all as specified and directed by Engr-in-Charge. 100 RM
50 50 Labour only of taking up or down steel tubing and connections of 20mm bore of pipe including cleaning and refixing in the same position as in roof /walls, etc during carrying out of water proofing treatment without damaging to existing services, etc. all as specified and directed by Engr-in-Charge. 80 RM
51 51 Labour only of taking up or down steel tubing and connections of 25 to 32mm bore of pipe including cleaning and refixing in the same position as in roof /walls, etc during carrying out of water proofing treatment without damaging to existing services, etc. all as specified and directed by Engr-in-Charge. 100 RM
52 52 Labour only for disconnecting existing over head tanks of capacity exc.500 and n.exc 1000 ltr, setting aside or lowering if required for repair of roof water proofing treatment and hoisting, reconnecting and re-fixing in position after necessary work without damaging to existing services etc. all as specified and directed. 20 Each
53 53 Demolition of cement concrete of any description and in any position provided as in roof padding, roof curb etc complete all as specified and as directed. \nNote: -\n(a) Demolition should be done carefully to roof slab. \n(b) Any damage occurred in the roof surfaces during demolition shall be made good by the contractor without extra cost to the department.\n(c) Disposal of debris/retrieved materials shall be thrown out of site at place as directed by the Engineer-in-Charge.\n\n 50 Cum
54 54 Taking down/dismantling loose/damage concrete including plaster of any description and in any position from RCC structures like chajja, fins, louvers, parapet, column, beam, and of lintel by hammering with wooden mallets carefully chipping off the old concrete surface including cutting of rusted reinforcement if so required and disposal of old debris to outside the premises complete all as specified and as directed. 1.5 Cum
55 55 Dismantling of asbestos cement (corrugated, semicorrugated,etc sheets in roof coverings all as directed 48 Sqm
56 56 Cleaning the existing surface of concrete and reinforcements as obtained after execution of item No. 1,2 here in before by wire brush including scrapping & cleaning with emery paper and washing down with water as required and applying “Solvent free epoxy concrete bonding agent” as per manufacturer’s instructions on old concrete surfaces for bonding with new concrete complete all as specified & as directed. 20 Sqm
57 57 Supply only. Solvant free Epoxy concrete bonding agent. \nMake : Nitobond EP of FOSROC/Carbodur of SIKA/ or equivalent in PEDILITE \n 2 Ltr
58 58 M&L for preparing new plastered surfaces of wall and applying two coats of acrylic weather paint exterior grade over a coat of weather coat primer complete all as specified and directed by Engr In Charge. 143.6 Sqm
59 59 Removing existing water proofing treatment where so ever exist (except concretepadding) and removing debris/rubbish off the site as directed 1620 Sqm
60 60 Material and labour for water proofing treatment with APP based standard membrane over PCC padding in roof with the following courses of treatment for:-\n(a) Apply bituminous primer (IS 3384) @ 0.40 Kg per sqm of the surface area including cleaning the surfaces complete all as specified.\n(MAKE : TEXSA/BITUMAT/BITUNIL/SIKA)\n(b) Apply APP plastomeric bitumen based mineral finished water proofing membrane polyester reinforced(4 Kg/Sqm) with 10cm over laps and torch bonded at joints including surface preparation before and after application of treatment as per manufactures instruction complete all as specified. (Make of APP Membrane: Moply FP 3 mm mineral of TEXA/WP Shield 103 PM of SIKA or Equivalent material of BITUNIL/BITUMAT. (c) Over the membrane provide a solar reflective bituminous aluminium paint @ 0.1 kg/sqm prescribed by manufacturer complete all as specified. 1620 Sqm
61 61 M&L for 15mm thk mineral board fine figured in true horizontal level of size 600mmx600mm as in false ceilling hot dipped, including galvonised steel section, exposed surface with pre-coted capping, main centre to centre size of 24mmx32mm having 0.27mm guage at every 1200mm centre to centre and wall angle of size 19mmx19mm having 0.35mm guage fixed to the periphery of the wall. the above grill is suspended at every 1200mm c/c on both directions using 3mm thk pre-strightened GI wire, laying etc. complete as directed by Engr-in-charge. 30 Sqm
62 62 S&F 6.00 mm thick polycarbonate sheets of superior quality in semi circle shape on roofs/wall cladding of desired colour and fixed with aluminium metal flat/angle/tee sections including rubber beadings and silicon water proofing sealent jell for joining the sheets together and self tightening screws of reputed quality and make complete all as specified and directed 17 Sqm
63 63 Supply and fix in repair stop cock of 15mm bore fancy type, chromium plated with long shank and cup cast copper alloy, screwed down, high pressure, with crutch handle, screwed both ends for brass ferrule CAT NO F380004CP of HINDWARE complete all as specified and as diected. 4 Each
64 64 Supply and fix in repair bib taps of 15mm bore fancy type, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule CAT NO F520005CP of HINDWARE complete all as specified and as diected. 2 Each
65 65 Supply and fix in repair Pillar taps, 15mm bore, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe or for connection pipe CAT NOF520002CP of HINDWARE complete all as specified and as diected. 4 Each
66 66 Supply and fix in repairs Vitreous china wash down water closet western pattern (COMMODE) CAT NO 20107 of HINDWARE including making necessary connection to soil pipes and flushing cistern complete all as specified and as directed. 2 Each
67 67 M&L viterious china bowl urinal sensor type white CAT NO 60021 of HINDWARE with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) 2 Each
68 68 Supply and fix Health faucet of 15mm bore, screwed both ends for iron pipe or for brass ferrule CAT NO F160108CP of HINDWARE complete all as specified and as diected. 2 Each
69 69 M&L Point Wiring using approved Colour Code as per IS with Zerohologen Flame Retardent (HFFR) smoke free, non-toxic, non-corrosive with Copper Cable 1.5 Sqmm (nominal area) Single Core insulated including unsheathed stranded 1100 Volts grade Copper Conductor Cable 1.5 Sqmm (nominal area) as Earth Continuity Conductor drawn in and including Concealed ERW Conduit Stove Enamelled black, heavy duty with Conduit Accessories such as Tee, Bend, Elbow, Junction Box duly Tested and Certified by CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked, complete all as specified and as directed. 3 Per Point
70 70 M&L Point Wiring using approved Colour Code as per IS with Zerohologen Flame Retardent (HFFR) smoke free, non-toxic, non-corrosive with Copper Cable 2.5 Sqmm (nominal area) Single Core insulated including unsheathed stranded 1100 Volts grade Copper Conductor Cable 2.5 Sqmm (nominal area) as Earth Continuity Conductor drawn in and including Concealed ERW Conduit Stove Enamelled black, heavy duty with Conduit Accessories such as Tee, Bend, Elbow, Junction Box duly Tested and Certified by CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked, suitable for 16 Amp Socket, complete all as specified and as directed. 1 Each
71 71 S&F Flame Proof, Weather Proof Switch Socket with Plug Combined in LM6, Termination Box in LM6, 16 Amp, 250 Volt, 2 Pin and Earth Plug, Fully interlocked suitable for installation in hazardous as per IS-2147/62 alluminium alloy/cast iron neoprene gasket degree of protection IP 65 and Certified CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked, complete all as specified and as directed. MAKE : BALINGA/ FLEX PRO/ SHYAM/ SUDHIR 1 Each
72 72 S&F Flame Proof, Weather Proof Switch Socket with Plug Combined in LM6, Termination Box in LM6, 256 Amp, 415 Volt, TPN, 2 Pin and Earth Plug, Fully interlocked suitable for installation in hazardous as per IS-2147/ 62 alluminium alloy/cast iron neoprene gasket degree of protection IP 65 and Certified CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked, complete all as specified and as directed.\nMAKE : BALINGA/ FLEX PRO/ SHYAM/ SUDHIR 1 Each
73 73 S&F Flame Proof Distribution Box SPN, 4-way with Bus-bar Weather Proof in Cast Aluminium LM-6 Enclosure, opened by externally Spring type knobs, complete with M-25 Cable Entry to suit Incoming Cable and 1 No. M-2 Cable Entries for Out-going Cables from bottom, suitable for fixing on Wall/ Column/ Sheet Structure, etc. duly Epoxy Powder Coated with Flame Proof Flexible Metallic Conduit upto 1.0 Metre in length including MCB SPN 40 Amp (1 No.) and MCB SP upto 25 Amp (2 No.) as Out-going duly Tested and Certifed by CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked, complete all as specified and directed. MAKE : BALINGA/ FLEX PRO/ SHYAM/ SUDHIR 1 Each
74 74 M&L Flame Proof Sub-main Wiring with 2-Runs of 06 Sqmm, Single Core, Halogen Free Flame Retardant (HFFR), insulated, unsheathed, multi-stranded, 1100 Volts grade, Copper Conductor Cable and 1-Runs of 6 Sqmm Earth Wire of Single Core, Halogen Free Flame Retardant (HFFR), insulated, unsheathed, multi-stranded, 1100 Volts grade, Copper Conductor Cable, drawn through and including ERW Conduit 40mm dia, heavy duty with necessary Conduit Accessories such as Tee, Bend, Elbow, Junction Box duly tested and Certified by CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked, Concealed/grouting Conduit on Brick Walls, etc. and Making Good disturbed Surfaces of Brick Walls, Ceilings, Floors, etc. in Cement Mortar 1:3 and necessary Surface Treatments so as to match with the Existing Finishes, complete all as specified and as directed. 50 RM
75 75 S & F switch flame proof rotary type with termination box in LM6 16A single pole 250 V complete all as specified and directed 2 Each
76 76 Supply and fix flame proof exhaust fan 220 volt, 50 Hz 380mm sweep with louver including three core copper conductor .5 sqmm for connection complete all as specified and directed by Engr-in-charge 1 Each
77 77 S & F Flame proof type FLP-WP LED light fitting 1x18 W made of aluminium alloy LM-6 connector block etc complete with all accessories prewired and including connecting up with twin cosre twisted flexible copper conductor cable with suitable size complete all as specified and directerd. 2 Each