Military Engineer Services-MES has published Repair To Footpath Hardstanding Plinth Protection Drain And Certain Br Works In Zone A Area Under Ge I Gos. Submission Date for this Tender is 05-02-2021. Footpath Work Tenders in GOPALPUR MILITARY STATION Odisha. Bidders can get complete Tender details and download the document.
Name of Work: REPAIR TO FOOTPATH HARDSTANDING PLINTH PROTECTION DRAIN AND CERTAIN B/R WORKS IN ZONE A AREA UNDER GE I GOS. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all as specified & directed. | 176.78 | Cum | |
2 | 2 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. | 17.4 | Cum | |
3 | 3 | M&L for PCC 1:2:4 type B-1 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed. | 3.75 | Cum | |
4 | 4 | M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed. | 150 | RM | |
5 | 5 | M&L for add or deduct for each 25mm girth or part thereof over or under 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed. | 75 | RM | |
6 | 6 | M&L for Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m depth in soft /loose soil etc complete all as specified and directed | 21 | Cum | |
7 | 7 | M&L for Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil etc complete all as specified and directed | 10 | Cum | |
8 | 8 | M&L for Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. | 11 | Cum | |
9 | 9 | S&F reinforced concrete pipes, class NP-2, laid and jointed complete with collars of 300mm dia as in repair complete all as specified and directed. | 20 | RM | |
10 | 10 | S&F reinforced concrete pipes, class NP-2, laid and jointed complete with collars of 450mm dia as in repair complete all as specified and directed. | 20 | RM | |
11 | 11 | M&L for 50 mm High density polyethelyene pipes (HDPE) of pressure rating 6kgf/sqcm laid in trenches complete all as specified and directed. | 40 | RM | |
12 | 12 | M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed. | 75 | Cum | |
13 | 13 | M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as sub base of floor complete all as specified and directed. | 500 | Sqm | |
14 | 14 | M&L for 50 mm thick cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in path/hard standing surface finished even and smooth without using extra cement complete all as specified and directed. | 250 | Sqm | |
15 | 15 | M&L for forming construction joints 50 mm x 10 mm wide filled with sealing compound Grade A complete all as specified and directed. | 10 | 10RM | |
16 | 16 | M&L preparing concrete floor surfaces and applying a coat of epoxy resin based primer (nitroprime 25 of M/S Fosroc) and applying two coats of high build, epoxy resin based floor coating (nitroflor FC 145 of M/s Fosroc or equivalent) complete all as specified and directed. | 50 | Sqm | |
17 | 17 | M&L 75 mm thick cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in sub base,floor , plinth protection etc and finishing cement concrete even and smooth without using extra cement complete all as specified and directed. | 200 | Sqm | |
18 | 18 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed. | 125 | Sqm | |
19 | 19 | M&L for 10 mm thick heavy duty exterior designer tiles of size 300 mm x 300 mm as in floor set, jointed in neat cement slurry and pointed with grey cement and pigment complete all as specified and directed. | 850 | Sqm | |
20 | 20 | M&L for screed bed or bedding layer of mortar 20 mm thick in CM 1:6 for laying floor finishes complete all as specified and directed. | 850 | Sqm | |
21 | 21 | M&L chequered tile of size 200 x 200 x 18 to 20mm set and jointed in neat cement slury and pointed in grey cement and pigments to match over 20mm thick screed bed in CM 1:6 complete all as specified & directed. | 300 | Sqm | |
22 | 22 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. | 11.18 | Cum | |
23 | 23 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. | 15 | Cum | |
24 | 24 | S&F machine pressed precast concrete interlocking paver block any shape & size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement & pigment complete all as specified & directed. | 300 | Sqm | |
25 | 25 | Demolition of RCC of any description and in any position not other wise specially provided for reinforcement cut as required to facilitate demolition complete all as specified and directed. | 5 | Cum | |
26 | 26 | M&L for pre cast cement concrete 1:2:4, type B-1, using 20mm graded stone aggregate as in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 complete all as specified and directed. | 5 | Cum | |
27 | 27 | M&L for Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. | 785 | Kg | |
28 | 28 | M&L for TMT Bars 5 mm dia & over upto & including 10 mm dia in stirrups, spaces & binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified & directed. | 219.8 | Kg | |
29 | 29 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. | 18.5 | Per Quintal | |
30 | 30 | M&L for Fe 410-W (Gde E-250 quality A) Framed work as in doors or gates of angle or other section with gusset plates,rails,braces etc complete,drilled for fixing of steel sheeting or other covering. Doors,etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed | 1850 | Kg | |
31 | 31 | M&L preparation of new or previously untreated steel surfaces of any description n exc 10cm in width or girth and priming with red oxide zinc chrome and applying two coat of synthetic enamel paint complete all as specified and directed. | 100 | per 10 RM | |
32 | 32 | M&L for two coats of synthetic enamelled paint to new steel surfaces after preparation over a coat of red oxide primer area over exc 10cm in width or girth etc complete all as specified and directed. | 100 | Sqm | |
33 | 33 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. | 54.5 | Cum | |
34 | 34 | M&L Brick work using fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. | 54.5 | Cum | |
35 | 35 | Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. | 200 | Sqm | |
36 | 36 | M&L for rendering 15mm thick in CM 1:6 on brick or concrete surface, finishing even and smooth without using extra cement complete all as specified and directed. | 745 | Sqm | |
37 | 37 | M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of cement based paint complete all as specified and directed | 372.5 | Sqm | |
38 | 38 | M&L for complete removal of existing treatment on walls and applying two coats of cement based paint complete all as specified and directed | 2680 | Sqm | |
39 | 39 | M&L for preparing new plastered or unplastered surfaces of walls and applying three coats of white wash complete all as specified and directed | 372.5 | Sqm | |
40 | 40 | M&L preparation of old painted surfaces of walls and applying one coat of cement based complete all as directed. | 3000 | Sqm | |
41 | 41 | M&L preparation of old painted surfaces of walls and applying one coat of white wash complete all as specified and directed. | 2000 | Sqm | |
42 | 42 | M&L preparation of old painted steel surfaces of any description n exc 10cm in width or girth and priming with red oxide zinc chrome and applying two coat of synthetic enamel paint complete all as specified and directed. | 200 | per 10 RM | |
43 | 43 | M&L preparation of old painted steel surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. | 200 | Sqm | |
44 | 44 | S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed | 50 | RM | |
45 | 45 | S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed. | 10 | Each | |
46 | 46 | M&L for cutting and removing wild bushes/ vegetation, surface dressing around the septic tank/sock well/ manholes to a distance of 2 mtrs all around and depositing surplus spoil/ rubbish n.exc 50 m complete all as specified and directed. | 110 | Sqm | |
47 | 47 | M&L for cutting and removing wild bushes/ vegetation, etc at bldgs above the 2m height from GL and depositing surplus spoil/ rubbish exc 100M but n.exc 500 M complete all as specified and directed. | 110 | Each | |
48 | 48 | M&L for Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 300 mm to 450 mm internal dia of pipe complete all as specified and directed. | 40 | RM |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy