| 1 | 1 | Substation Equipments | | | |
|---|
| 2 | 1.01 | 3P4W Interface Energy Meters (ABT type) 0.2s Class 1A with TTB & BCS | item1 | 2757 | No. |
|---|
| 3 | 1.02 | Wired Indoor Meters Panel suitable for 8 meters | item2 | 110 | No. |
|---|
| 4 | 1.03 | Wired Outdoor Meters Panel suitable for 8 meters | item3 | 15 | No. |
|---|
| 5 | 1.04 | 16 P Industrial Grade unmananged Network switch | item4 | 373 | No. |
|---|
| 6 | 1.05 | 8 P (6CU + 2 SFP) Industrial Grade unmananged Network switch | item5 | 130 | No. |
|---|
| 7 | 1.06 | 4 Ports line interfacing unit (LIU) with Patch Chords | item6 | 130 | No. |
|---|
| 8 | 1.07 | Data concentrator unit (DCU)/ communication Gateway (IG) with dual SIM Modem alongwith enclouser and accessories | item7 | 438 | No. |
|---|
| 9 | 1.08 | Cat-6 cable-unshielded | item8 | 15000 | meters |
|---|
| 10 | 1.09 | PVC conduit Pipe - 3/4\" with accessories for Cat-6 cable | item9 | 14000 | meters |
|---|
| 11 | 1.1 | 4C x 4 Sq. mm armoured cable for PT | item10 | 18000 | meters |
|---|
| 12 | 1.11 | 4C x 4 Sq. mm armoured cable for CT | item11 | 36000 | meters |
|---|
| 13 | 1.12 | 3C x 2.5 Sq. mm un-armoured cable for DCU & switches | item12 | 9000 | meters |
|---|
| 14 | 1.13 | Armoured F.O. (2 pair) | item13 | 6000 | meters |
|---|
| 15 | 1.14 | HDPE conduit - 40/33 with accessories | item14 | 6000 | meters |
|---|
| 16 | 1.15 | Hand Held Unit (CMRI) alongwith software and accessories | item15 | 20 | No. |
|---|
| 17 | 1.16 | High Resolution watt hour (3 phase 4 wire) ERSS meter of 0.02 accuracy class portable | item16 | 2 | No. |
|---|
| 18 | 2 | CDC Equipments | | | |
|---|
| 19 | 2.01 | Database Server | item17 | 2 | Nos. |
|---|
| 20 | 2.02 | Application Server | item18 | 2 | Nos. |
|---|
| 21 | 2.03 | Communication(API) Server | item19 | 2 | Nos. |
|---|
| 22 | 2.04 | Web Server | item20 | 2 | Nos. |
|---|
| 23 | 2.05 | Backup Management Server with Backup & Recovery Management Software | item21 | 1 | Nos. |
|---|
| 24 | 2.06 | 42 U Server / Network Rack | item22 | 2 | Nos. |
|---|
| 25 | 2.07 | NAS (with Minimum 15TB Usable data storage as per technical specification ) | item23 | 1 | Nos |
|---|
| 26 | 2.08 | Storage Area Network (SAN) based Storage Solution with Minimum 15TB Usable data storage as per technical specification | item24 | 1 | Nos. |
|---|
| 27 | 2.09 | SAN Switches | item25 | 2 | Nos. |
|---|
| 28 | 2.1 | 24 Port (Layer 3 ) 1G Network Switch as per Technical Specification | item26 | 4 | Nos. |
|---|
| 29 | 2.11 | Router as per technical specification | item27 | 2 | Nos. |
|---|
| 30 | 2.12 | Firewall with HA license as per technical specification | item28 | 2 | Nos. |
|---|
| 31 | 2.13 | KVM Switch 16 Port with 17” Console | item29 | 1 | Nos. |
|---|
| 32 | 2.14 | Server Management Console for centralize monitoring , NMS, Patch Management Etc.along with Network Management Software, Patch Management Software, Anti-Virus for End point Protection of Servers & Clients (As per Technical Specification for required nos of nodes at CDC & DR) | item30 | 1 | Lot |
|---|
| 33 | 2.15 | GPS Time Synchronization system (These shall be configured as dual redundant) | item31 | 2 | Nos. |
|---|
| 34 | 2.16 | Workstation with Windows 10 Pro OS, MS Office, PDF Reader cum Editor | item32 | 4 | Nos. |
|---|
| 35 | 2.17 | High Performance Laptop as per technical Specification | item33 | 4 | Nos |
|---|
| 36 | 2.18 | Multifunction Printers | item34 | 2 | Nos. |
|---|
| 37 | 2.19 | RDBMS Software | item35 | 1 | Lot |
|---|
| 38 | 2.2 | Antivirus for all servers/Laptop/ Workstation etc. | item36 | 19 | Nos. |
|---|
| 39 | 2.21 | Windows/ Linux OS License for Servers (Latest Edition) | item37 | 10 | Nos. |
|---|
| 40 | 2.22 | DAS/AMR Software | item38 | 1 | Nos. |
|---|
| 41 | 2.23 | MDP Software Module | item39 | 1 | Nos. |
|---|
| 42 | 2.24 | ABT scheduling system | item40 | 1 | Nos. |
|---|
| 43 | 2.25 | Open Access transaction management system for Open Access (OA) | item41 | 1 | Nos. |
|---|
| 44 | 2.26 | Transmission Outage Planning | item42 | 1 | Nos. |
|---|
| 45 | 2.27 | Energy accounting system | item43 | 1 | Nos. |
|---|
| 46 | 2.28 | Settlement system (Deviation, Reactive, Congestion) | item44 | 1 | Nos. |
|---|
| 47 | 2.29 | MIS Reporting for SLDC | item45 | 1 | Nos. |
|---|
| 48 | 2.3 | Payments Accounting System for SLDC | item46 | 1 | Nos. |
|---|
| 49 | 2.31 | Master Data Management , data Archival & Retrieval Module | item47 | 1 | Nos. |
|---|
| 50 | 2.32 | Demand Forecasting module | item48 | 1 | Nos. |
|---|
| 51 | 2.33 | Data Migration & Integration Module | item49 | 1 | Nos. |
|---|
| 52 | 2.34 | Design and development of dynamic and interactive website & Mobile Application of SLDC | item50 | 1 | Nos |
|---|
| 53 | 2.35 | UPS System (20 KVA) ( 2 hour backup)-(These shall be configured as dual redundant) | item51 | 2 | Nos |
|---|
| 54 | 2.36 | Workstation Desk | item52 | 6 | Nos |
|---|
| 55 | 2.37 | Chair | item53 | 12 | Nos |
|---|
| 56 | 3 | DISASTER RECOVERY CENTER Equipments | | | |
|---|
| 57 | 3.01 | DR Server | item54 | 1 | Nos |
|---|
| 58 | 3.02 | NAS (with Minimum 15TB Usable data storage as per technical specification ) | item55 | 1 | Nos |
|---|
| 59 | 3.03 | 24 Port (Layer 3 ) 1G Network Switch as per Technical Specification | item56 | 1 | Nos |
|---|
| 60 | 3.04 | Workstation with Windows 10 Pro OS, MS Office, PDF Reader cum Editor | item57 | 1 | Nos |
|---|
| 61 | 3.05 | UPS System (5 KVA) ( 2 hour backup) | item58 | 1 | Nos |
|---|
| 62 | 4 | Mandatory Spares | | | |
|---|
| 63 | 4.01 | 3P4W Interface Energy Meters (ABT type) 0.2s Class 1A with TTB & BCS | item59 | 55 | No. |
|---|
| 64 | 4.02 | 16 P Industrial Grade unmananged Network switch | item60 | 8 | No. |
|---|
| 65 | 4.03 | 8 P (6CU + 2 SFP) Industrial Grade unmananged Network switch | item61 | 4 | No. |
|---|
| 66 | 4.04 | Data concentrator unit (DCU)/ communication Gateway (IG) with dual SIM Modem alongwith enclouser and accessories | item62 | 9 | No. |
|---|
| 67 | 4.05 | Cat-6 cable-unshielded | item63 | 300 | meters |
|---|
| 68 | 4.06 | PVC conduit Pipe - 3/4\" with accessories for Cat-6 cable | item64 | 280 | meters |
|---|
| 69 | 4.07 | Database Server | item65 | 1 | No. |
|---|
| 70 | 4.08 | 24 Port (Layer 3 ) 1G Network Switch as per Technical Specification | item66 | 1 | No. |
|---|
| 71 | 4.09 | Router as per technical specification | item67 | 1 | No. |
|---|
| 72 | 4.1 | Firewall with HA license as per technical specification | item68 | 1 | No. |
|---|
| 73 | 4.11 | GPS Time Synchronization system | item69 | 1 | No. |
|---|
| 74 | 4.12 | Workstation with Windows 10 Pro OS, MS Office, PDF Reader cum Editor | item70 | 1 | No. |
|---|
| 75 | 4.13 | MCCB/MCB/Isolator/ Switch/ Contactor of each type & rating (as applicable & used inside UPS panel) | item71 | 1 | Lot |
|---|
| 76 | 4.14 | Fuse of each type & rating (if applicable) | item72 | 5 | Lot |
|---|
| 77 | 4.15 | DC Filter assembly | item73 | 1 | Lot |
|---|
| 78 | 4.16 | Input AC Filter assembly | item74 | 1 | Lot |
|---|
| 79 | 4.17 | Output AC Filter assembly | item75 | 1 | Lot |
|---|
| 80 | 4.18 | Electronic Printed Circuit Board/ Card of each type (including all cards/ modules for rectifier/ charger, inverter, system card, display module, interface cards etc. | item76 | 1 | Lot |
|---|
| 81 | 4.19 | Power Semiconductor devices of each type & rating such as SCRs, IGBTs etc. for rectifier/charger module, Inverter module, static Switch module for all the three phases (exclude those items which are covered under item-4.18 above) | item77 | 1 | Lot |
|---|
| 82 | 5 | Training | | | |
|---|
| 83 | 5.01 | Training for personnel at Generating/Transmission/Utility substation | item78 | 100 | No of User |
|---|
| 84 | 5.02 | Training programs for system users | item79 | 30 | No of User |
|---|
| 85 | 5.03 | Training program for system hardware and software support team | item80 | 8 | Nos of user |
|---|
| 86 | 6 | AMC Services | | | |
|---|
| 87 | 6.01 | First Year AMC Charges during warranty Period for CDC equipments | item81 | 1 | Lot |
|---|
| 88 | 6.02 | First Year AMC Charges during warranty Period for Disaster Recovery(DR) Centre equipments | item82 | 1 | Lot |
|---|
| 89 | 6.03 | First Year AMC Charges during warranty Period for for Substation end equipment | | | |
|---|
| 90 | 6.031 | 3P4W Interface Energy Meters (ABT type) 0.2s Class 1A with TTB & BCS | item83 | 2757 | Nos |
|---|
| 91 | 6.032 | DCUs with Modem and All Networking equipments LAN switch, LIUs along with all control & communication cables, Communication cable in between Energy meter to LAN Switch up to DCU / Gateway, Console and all other H/W, S/W per Sub Station/ Site. | item84 | 438 | Lot |
|---|
| 92 | 6.4 | Cyber audit from CERT-IN 3rd party empaneled vendor for 1 year during warranty period | item85 | 1 | Year |
|---|
| 93 | 6.5 | Six Years AMC Charges after warranty Period for CDC end equipments | item86 | 1 | Lot |
|---|
| 94 | 6.6 | Six Years AMC Charges after warranty Period for Disaster Recovery Centre equipments | item87 | 1 | Lot |
|---|
| 95 | 6.7 | Six Years AMC Charges after warranty Period for Substation end equipment | | | |
|---|
| 96 | 6.701 | 3P4W Interface Energy Meters (ABT type) 0.2s Class 1A with TTB & BCS | item88 | 2757 | Nos |
|---|
| 97 | 6.702 | DCUs with Modem and All Networking equipments LAN switch, LIUs along with all control & communication cables, Communication cable in between Energy meter to LAN Switch up to DCU / Gateway, Console and all other H/W, S/W per Sub Station/ Site. | item89 | 438 | Lot |
|---|
| 98 | 6.8 | Cyber audit from CERT-IN 3rd party empaneled vendor for 6 year after warranty period. | item90 | 6 | Year |
|---|
| 99 | 6.9 | Provision for the addition of additional IEMs & DCUs etc. during AMC Period | | | |
|---|
| 100 | 6.901 | Supply of Interface Energy Meters along with all accessories & necessary wiring & cabling etc., commissioning, interfacing, integration with DCU as well as other SAMAST elements and reporting of data | item91 | 140 | Nos |
|---|
| 101 | 6.902 | Supply of DCUs with Modem, 16 P Industrial Grade unmananged Network switch along with enclosure / accessories & necessary wiring & cabling etc., commissioning, interfacing, integration with IEMs as well as other SAMAST elements and reporting of data | item92 | 22 | per site |
|---|
| 102 | 7 | Note:- \n1. The Annual Maintenance Charges for Substation end, CDC end and DR end equipment per annum shall be at least 1 % of the supply cost of the respective Equipment (excluding spares cost).\n\n2. The Maintenance charges for addition of additional IEMs & DCU shall be paid additionally on pro rata basis as per AMC rates.\n\n3. The communication charges like SIM based service for meter data communication to CDC, MPLS based Internet connection charges for CDC etc., Leased line charges would be borne by the Bidder till the handing over of the project. Thereafter, these charges shall be paid by HVPNL.\n\n4. Various items have different warranty periods viz. IEM have 5 years warranty, Servers/San storage/NAS Storage/KVM Switch have 3 years warranty. Such aspects may be kept in mind while quoting the price for AMC by the bidder.\n\n5. Supply and Erection cost on account of CDC Equipment (Software & Hardware) should not be less than 15% of the Supply & Erection cost of overall Project Equipment.\n\n6. The requirement of Mandatory spares would be reviewed at the time of detailed engineering in consultation with the successful bidder. | | | |
|---|