Military Engineer Services-MES has published Cleaning/ Repair To Sewage Lines , Septic Tanks , Manholes And Other Related Works In Domestic Area Ge Air Force Jammu. Submission Date for this Tender is 03-02-2021. Sewerage Construction Tenders in Air Force Station Jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Name of Work: CLEANING/ REPAIR TO SEWAGE LINES, SEPTIC TANKS, MANHOLES AND OTHER RELATED WORKS IN DOMESTIC AREA GE AIR FORCE JAMMU | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Cleaning manually of blocked WC seat trap, inside house and gully trap it includes remove/refixing of grating and cleaning of WC's trap,kitchen/bath traps any type/pattern (pedestal/squatt pattern) upto 1st manhole and making the drain pipe of any size full functional by flushing with water to entire satisfaction of Engr-in-Charge including cleaning of 1st manhole and removing the waste material/sludge etc to a distance n.exc 50m and burring the same in pits complete all as directed by Engr-in-Charge.(Measurement will be carried out each time depending on blockage) | 3000 | each job | |
2 | 2 | Cleaning/clearing mechanically the sewage line of any description / SGSW pipe of size 100mm dia to 200mm dia at any depth , removing any type of blockage including destling , descaling & dechocking with combine hydralic operated sewer suction cum jetting machine mounted on LCV/HCV by using high pressure thermo plastic water jetting hose and throgh conical ronnd shaped nozzle with piston action rodding from manhole to manhole or from manhole to septic tank / well through sewer line (Measurement will be carried out all as directed by Engr-in-charge. | 4000 | running meter | |
3 | 3 | Cleaning of underground SGSW pipe of size 150mm dia by rodding from manhole to manhole or from manhole to septic tank/well) including taking off manhole cover and cleaning of manholes of any size and depth and reomving waste material/sludge to a distance of n.exc 50m and burrying the same pit and replacing manhole cover in position after cleaning ( Measurement will be carried out each time depend on blockage ) Complete all as directed by Engr-in-Charge. | 4000 | running meter | |
4 | 4 | Cleaning of septic tanks, soakage well/pits of any depth including inlet and outlet chamber and removing sludge(in solid & semi solid ), silt, both organic and in-organic nature including any other type of waste material after plugging of incoming sewage line and removing waste material /sludge etc to a distance n.exc 100m and burrying the same in pit. Complete all as specified and directed by Engr-in-Charge. | 80 | cum | |
5 | 5 | Bailing out water directly from septic tank/soakage well/manhole/grease trap of any size and any depth with suitable capacity pumps/suction machine to a distance not less than 50 metre away in such a manner as to Disposal of water, not to cause inconvenience /nuisance in the area or to cause damage to the property structures near by all as spd and directed by Eng-in-charge(All works to be carried out under foul conditions). | 100 | cum | |
6 | 6 | Excavation in trenches in any type of soil n.exc 1.5m wide and n.exc 1.5m depth in foundations etc for manholes, sewage line and and getting out complete all as specifed. | 80 | Cum | |
7 | 7 | Excavation in trenches in any type of soil n.exc 1.5m wide and exc 1.5m but not exc 3.00 mtr depth in foundations etc for manholes, sewage line and and getting out complete all as specifed. | 40 | Cum | |
8 | 8 | Excavation in trenches in any type of soil n.exc 1.5m wide and exc 3.00m but not exc 4.500 mtr depth in foundations etc for manholes, sewage line and and getting out complete all as specifed. | 20 | Cum | |
9 | 9 | Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any type of soil complete all as specifed. | 95 | Cum | |
10 | 10 | Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specifed. | 40 | Cum | |
11 | 11 | Demolition of brick work or stone/ boulder masonary , bult in cement mortor incl all quoins, arches, pillars etcincluding depositing unservicable brick and stacking for reuse including cleaning of bricks and deposting off all debries & rubbish off permises to a distance not exceeding 100 mtr complete all as specifed. | 25 | Cum | |
12 | 12 | Material and labour Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:6 for manhole and external pointed flush in same mortar as the work proceeds. Complete all as specified. | 20 | Cum | |
13 | 13 | Labour Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:6 for manhole and external pointed flush in same mortar as the work proceeds. Complete all as specified. but except bricks. | 5 | cum | |
14 | 14 | Demolition of cement concrete as in bed to drain pipe 150/200mm dia including packing under and haunching against the sides of pipe or as in manhole benching/bed etc. Complete all as specified. | 170 | running meter | |
15 | 15 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cemnt concrete 1:2:4 type B-1 smooth finished and forming benching as required. Internal dia of pipe 150mm. Complete all as specified or directed by engineer-in-charge. | 20 | Each | |
16 | 16 | Supply and Fixing of Reinforced concrete pipe class NP-2 laid and jointed complete with coller 200 mm dia. Complete all as specified or directed by engineer-in-charge. | 150 | running meter | |
17 | 17 | Material and labour for Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 for 150/200mm bore pipes.Complete all as specified or directed by engineer-in-charge. | 120 | running meter | |
18 | 18 | Supply and fixing Salt glazed stoneware (SGSW) grade 'A' drain pipes 150mm bore laid and jointed on concrete bed, complete including testing etc all as specified and shown on drgs (concrete bed shall be measured and paid for separately). Complete all as specified or directed by engineer-in-charge. | 50 | running meter | |
19 | 19 | Supply and fixing Salt glazed stoneware (SGSW) grade 'A' drain pipes 200mm bore laid and jointed on concrete bed, complete including testing etc all as specified and shown on drgs (concrete bed shall be measured and paid for separately). Complete all as specified or directed by engineer-in-charge. | 70 | running meter | |
20 | 20 | Demolition of cement concrete (unreinforced) as in floors and paving n exc 15cm thickness (below or above ground level) including deposal off rubbish to a distance not exc 100 mtr. Complete all as specified or directed by engineer-in-charge. | 2 | cum | |
21 | 21 | Material and labour Cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) in foundation filling and mass concrete. Complete all as specified or directed by engineer-in-charge. | 2 | cum | |
22 | 22 | M&L for cement concrete 1:2:4 type B1 using 20mm graded aggregate as in benching, bed plates, coping and the like including weathering, slightly rounded or chamfered angles as directed including formwork and finishing all exposed surfaces. Complete all as specified or directed by engineer-in-charge. | 2 | cum | |
23 | 23 | Taking down cement plaster of any description on brick wall ceiling and concrete surface etc including rackimg out joints,hacking for keys all as specifed and as directed by Engineer-in- Charge. | 50 | Square Metre | |
24 | 24 | Material and labour Rendering 15mm thick on brick surfaces in cement mortar 1:4 finished even and smooth without using extra cementcomplete all as specified. | 120 | Square Metre | |
25 | 25 | Demolition of reinforced cement concrete of man hole covers/cover slabs. as specifed and as directed by Engineer-in- Charge. | 3 | cum | |
26 | 26 | Precast cement concrete type B-1, 1:2:4 (20mm graded) aggregate as in manhole cover all as specifed including form work. Complete all as specified or directed by engineer-in-charge. | 3 | cum | |
27 | 27 | Supply and fixing Deformed or TMT steel bars 8mm or 10mm dia in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia. Complete all as specified or directed by engineer-in-charge. | 600 | Kg | |
28 | 28 | M & L for Mild steel angle iron/flat Iron work as in manhole cover frames and painted with two coats of bituminous paint. Complete all as specified or directed by engineer-in-charge. | 2000 | Kg | |
29 | 29 | S&F in reapired vitreous china wash down water closet pan ( pedestal pattern ) white complete including ‘P’ or ‘S’ trap , seat cover and fixing of flushing cistern, brackets, flushing pipe etc. Complete all as specified or directed by engineer-in-charge. | 10 | Each | |
30 | 30 | S&F in repaired vitreous china Orissa pan of pattern, long pan size 580x440mm , with ‘P’ or ‘S’ trap, front or back inlet and integral foot rest complete, including lime concrete bedding and connection to drain or outgoing pipe and to flushing pipe, and anti siphon pipe. Complete all as specified or directed by engineer-in-charge. | 20 | Each | |
31 | 31 | S&F in repair PVC valve less, syphonic action type flushing cistern, low level with inlet, ball valve float and handle including brackets of capacity 10 ltrs incl PVC connection wih brass nut on both ends and PVC flush pipe. Complete all as specified or directed by engineer-in-charge. | 19 | Each | |
32 | 32 | Supply and fixing in repairs vitreous china urinal flat back 465x355x265mm size , including grating and Connection to flushing pipe and outgoing pipe. Complete all as specified or directed by engineer-in-charge. | 10 | Each | |
33 | 33 | Taking down CI pipe (any size or pattern) incl fittings such as bends, shoes, head, swan neck etc incl cleaning for refixing or removal from site. Complete all as specified or directed by engineer-in-charge. | 150 | running meter | |
34 | 34 | Supply and fixing 100mm dia bore cast iron soil, waste and vent pipes (sand cast pipes) in any length with or without ears, with cement joint fixed on wall. Complete all as specified or directed by engineer-in-charge. | 30 | running meter | |
35 | 35 | Description all as per above Srl item above but 75mm dia. Complete all as specified or directed by engineer-in-charge. | 10 | running meter | |
36 | 36 | Supply and fixing in repair bends (any radius) dimension pieces or tapers (Large bore measured) 100mm dia. Complete all as specified or directed by engineer-in-charge. | 10 | Each | |
37 | 37 | Description all as per above Srl item above but bend size 75mm dia. Complete all as specified or directed by engineer-in-charge. | 5 | Each | |
38 | 38 | Supply and fixing stack clamp cut of 50 x 5mm flat iron and 16mm dia round iron stays including bolt and nuts and securing ends of stay to water pipes suitable for 100 mm dia pipe including taking down unservicable clamp. Complete all as specified or directed by engineer-in-charge. | 50 | Each | |
39 | 39 | S&F cast iron oval access doors 100mm. Complete all as specified or directed by engineer-in-charge. | 40 | Each | |
40 | 40 | S&F cast iron oval access doors 75mm. Complete all as specified or directed by engineer-in-charge. | 30 | Each | |
41 | 41 | S & F PVC (SWR) pipes 110mm single socketed , in any length with rubber ring joints fixed to walls. Complete all as specified or directed by engineer-in-charge. | 80 | running meter | |
42 | 42 | S & F PVC (SWR) pipes 75mm single socketed , in any length with rubber ring joints fixed to walls. Complete all as specified or directed by engineer-in-charge. | 30 | running meter | |
43 | 43 | S & F PVC (SWR) bends110mm. Complete all as specified or directed by engineer-in-charge. | 10 | Each | |
44 | 44 | S & F PVC (SWR) bends75mm. Complete all as specified or directed by engineer-in-charge. | 10 | Each | |
45 | 45 | S & F PVC (SWR) vent cowl 110mm. Complete all as specified or directed by engineer-in-charge. | 10 | Each | |
46 | 46 | S & F PVC (SWR) vent cowl 75mm. Complete all as specified or directed by engineer-in-charge. | 10 | Each | |
47 | 47 | SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II (if applicable) of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder. | |||
48 | 48 | Note: (1) The repair and painting has to be carried out as and when required basis and accordingly site will be available in piecemeal wise and as directed by Enginer-in-Charge. | |||
49 | 49 | (2) The contractor shall remove all the rubish/waste materials from the site of the work and deposit the same at a place exceeding 100 metres as directed by Engineer-in-Charge. The contractor shall also clean all joinery, floor, glass panes, fittings and fixtures etc. which may have been affected by the execution of work and will leave the site clean and tidy to the entire satisfaction of Engineer-in-Charge. The rates quoted by the Contractor for all the relevant items of BOQ shall be deemed to be included of this element. | |||
50 | 50 | (3) One Supervisior alongwith Two Conservency staff to be detailed to report daily at Complaint cell to collect complain slip from Complaint Cell and returned back the same after completed the work daily. |