Tender For Real Time Energy Efficiency Monitoring Instrument
Tender Overview
Project Description
Tender For Real Time Energy Efficiency Monitoring Instrument - Technical Specifications N1. Oxygen Range: 0 - 25% Regulation : 0.1% Accuracy : -0.1% +0.2% N2. Co ( Ppm ) Range : 0 - 10, 000 Ppm Or Better Regulation : 1 Ppm Accuracy : 20Ppm ‹400Ppm ± 5% ‹2000Ppm ±10% ›2000Ppm N3. Co ( % ) Range : 10% Or Better Regulation : 0.01% Accuracy : ±500Ppm <1% N±5% >1% N4. No Range : 0 - 5000 Ppm Or Better Regulation : 1 Ppm Accuracy : ±5Ppm <100Ppm N±5% >100Ppm N5. No2 Range : 0 - 1000 Ppm Or Better Regulation : 1 Ppm Accuracy : ±5Ppm <100Ppm±5% >100Ppm N6. So2 Range : 0 - 5000 Ppm Or Better Regulation :1 Ppm Accuracy : ±5Ppm <100Ppm±5% >100Ppm N7. Co2 Range : 20% Or Better Regulation : 0.01% Accuracy : ±7% Of Reading ±0.4% N8. Hc Range : 3000Ppm Or Better Regulation :10Ppm ± Accuracy : 7% Of Reading ±30Ppmv N9. H2s Range : 1000Ppm Or Better Regulation : 1 Ppm Accuracy : ±5Ppm <100Ppm ±5% >100Ppm N10. Draught ( Pressure Sensor ) : 0 – 150 Mbar Or Better N• Large Graphical Display - Up To 15 Lines Of Text / Data Can Be Displayed N• Wireless Link From The Handset To The Base Unit - With Cable Free Connection N• Gps Location - Pinpoint Exact Test Location N• Main Purge - Allows Sensor Zeroing Without The Need To Withdraw The Probe From N• The Flue - Refreshes The Sensors During Long Term Monitoring Automatically Protects The Sensors From Being Over-Ranged. N• Active Flow Control- Compensates For Sample Pressure Fluctuation & Filter Blocking By Adjusting The Pump Speed To Maintain A Set Sample Gas Flow Rate N• The Instrument Should Be Provided With 3Way Filtering System For Filtering Moisture, Dust & Sulphur Separately. N• User Manual, Calibration Report, Charging Adaptor Should Be Supplied N• The Instrument Should Be Provided With Built In Plain Paper Printer To Provide Hard Copy Of The Analysis. N• Approval: Tuv Independently Tested By Tüv Sud To En50379 N• The Instrument Should Be Provided With Built In Data Logger For Storing Data & Relevant Software For Analysis. N• Large Internal Memory - Can Store Up To 64, 000 Or More Tests N• Instrument Should Analyze Toxic Gases In All These Four Units Ppm, Mg / M3, Ppm ( Normal ) & Mg / Nm3 ( Normal ) N• Oxygen Referencing Facility Should Be Available For Analyzing The True Toxic Gas Emission From The Stack. N• The Instrument Should Have Capability Of On Site In Built Zero & Span Calibration With Touch Key Pad. N• Fuel Selection: Pre Programmed Fuels Facility Should Be Available & User Can Define Their Own Fuel Characteristics. N• Instrument Should Have Capability Of Measuring Differential Pressure Of Flue Gas Flow. N• Instrument Should Work Both In 230V Ac Power & Rechargeable Batteries & Battery Status Should Be Shown On The Display. N• On The Spot Cleaning & Changing Facility For Filters Should Be Available N• The Instrument Should Calculate Total Loss, Dry Loss, Wet Loss & Loss Due To Unburnt Carbon. N• The Instrument Should Have Facility For Increasing Or Decreasing The Pump Suction Capacity Based On Field Condition Suction Requirements. N• Portable With Water Trap, Particle Filter, Sulphur Filter, Sampling Probe Length – Customised N• ( 1 Mtr Long & 0.5 Mtr Long ) Temp: Up To 1000 °C With Sampling Hose: 2 Mtrs Long Or More N• Connectivity: N ( I ) Via Blue Tooth ( Wireless Connectivity With Live Analyser Readings – Capable Of Transfer N To Pc Or Android Phone ) N ( Ii ) Wireless N ( Iii ) Usb Connection To Pc – With The Appropriate Live Software To Monitor N Readings In “Real Time” N N N N N N N
BOQ
| Name of Work: Real Time Energy Efficiency Monitoring Instrument | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Real Time Energy Efficiency Monitoring Instrument | |||
| 2 | 1.01 | Technical Specifications \n1. Oxygen Range: 0 - 25% Regulation : 0.1% Accuracy : -0.1% +0.2%\n2. CO (ppm) Range : 0 - 10,000 ppm or better Regulation : 1 ppm Accuracy : 20ppm ‹400ppm ± 5% ‹2000ppm ±10% ›2000ppm\n3. CO (%) Range : 10% or better Regulation : 0.01% Accuracy : ±500ppm <1%\n±5% >1%\n4. NO Range : 0 - 5000 ppm or better Regulation : 1 ppm Accuracy : ±5ppm <100ppm\n±5% >100ppm\n5. NO2 Range : 0 - 1000 ppm or better Regulation : 1 ppm Accuracy : ±5ppm <100ppm±5% >100ppm\n6. SO2 Range : 0 - 5000 ppm or better Regulation :1 ppm Accuracy : ±5ppm <100ppm±5% >100ppm\n7. CO2 Range : 20% or better Regulation : 0.01% Accuracy : ±7% of reading ±0.4%\n8. HC Range : 3000ppm or better Regulation :10ppm ± Accuracy : 7% of reading ±30ppmv\n9. H2S Range : 1000ppm or better Regulation : 1 ppm Accuracy : ±5ppm <100ppm ±5% >100ppm\n10. Draught (pressure sensor) : 0 – 150 mbar or better\n• large graphical display - up to 15 lines of text/data can be displayed\n• wireless link from the handset to the base unit - with cable free connection\n• GPS location - pinpoint exact test location\n• Main purge - allows sensor zeroing without the need to withdraw the probe from\n• The flue - refreshes the sensors during long term monitoring automatically protects the sensors from being over-ranged.\n• Active flow control- compensates for sample pressure fluctuation & filter blocking by adjusting the pump speed to maintain a set sample gas flow rate\n• The instrument should be provided with 3way filtering system for filtering moisture, dust & Sulphur separately.\n• User manual, calibration report, Charging adaptor should be supplied\n• The instrument should be provided with built in plain paper printer to provide hard copy of the analysis.\n• Approval: TUV Independently tested by TÜV SUD to EN50379\n• The instrument should be provided with built in data logger for storing data & relevant software for analysis.\n• large internal memory - can store up to 64,000 or more tests\n• Instrument should analyze toxic gases in all these four units ppm, mg/m3, ppm(normal) & mg/nm3 (normal)\n• Oxygen referencing facility should be available for analyzing the true toxic gas emission from the stack.\n• The instrument should have capability of on site in built zero & span calibration with touch key pad.\n• Fuel selection: pre programmed fuels facility should be available & user can define their own fuel characteristics.\n• Instrument should have capability of measuring differential pressure of flue gas flow.\n• Instrument should work both in 230V AC power & rechargeable batteries & battery status should be shown on the display.\n• On the spot cleaning & changing facility for filters should be available \n• The instrument should calculate total loss, dry loss, wet loss & loss due to unburnt carbon.\n• The instrument should have facility for increasing or decreasing the pump suction capacity based on field condition suction requirements.\n• Portable with water trap, particle filter, Sulphur filter, Sampling probe length – customised\n• (1 mtr long & 0.5 mtr long) Temp: up to 1000 °C with sampling hose: 2 mtrs long or more\n• Connectivity:\n (i) Via blue tooth (wireless connectivity with live analyser readings – capable of transfer \n to PC or Android phone)\n (ii) Wireless \n (iii) USB connection to PC – with the appropriate live software to monitor \n Readings in “real time”\n\n\n\n\n\n\n | item1 | 1 | Nos |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
Completed