Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #26598427

Retrofitting Work In Different Villages Of Block Pansemal In Barwani Distt

Issued by Government Departments · Pansemal, Madhya Pradesh
Tender Value
2.01 Crore
Estimated cost
Bid Submission
27 Jan 2021
0 days left
EMD
2.01 Lakhs
Bank guarantee accepted
Document Fee
15000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pansemal → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Retrofitting Work In Different Villages Of Block Pansemal In Barwani Distt

BOQ

Name Of Work :-Design, Construction and Retrofitting/New Piped Water Supply Scheme under Jal Jeevan Mission at Village - 1. TEMLA 2.PANNALI Block PANSEMAL Distt. Barwani based on Tube wells including installation of electric submersible/centrifugal water motor pumps, Construction of 02 Nos. R.C.C. Overhead tanks. (01 No. Capacity 100 KL/12M At Temla, 01 No. Capacity 125KL/12M At Pannali), 02 Nos. sumpwells (01 No.- 40 KL At Temla, 01 No. 30KL At Pannali), pump houses, laying and jointing of rising main, distribution pipe line system, household tap connections, electric power connections at Tube wells/Sumpwells etc including cost of all material and labour with testing commissioning thereafter 90 Days of successful Trial Run of entire scheme.
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Supply & erection of readymade mini pump house (control panel box) GI sheet of 18 gauge of size 90cmx90cm x60cm with 40x40x5mm angle Iron frame to fix it 200mm below ground level with hold fasts grouted in foundation and 300mm above ground level for clearance suitable for fixing of control panel, fuse unit, main switch etc. as per approved specification. PHE (03.07.2018) uSOR. Item.no 17.18 p- 22816Each
22Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6\"tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe and connection cable.\n(a) 5 H.P. with 10 to 11 stages, Head Mt. 101-40 Discharge LPM 60-270. \nPHE (03.07.2018) uSOR. Item.no. 24.20.106 (iv) p-26722Each
33(c ) 10 H.P. with 20 stages, Head Mt. 184-80 Discharge LPM 60-270. PHE (03.07.2018) uSOR. Item.no. 24.20.106 (ix) p-26734Each
44Providing and jointing of following galvanized Iron (MS) Pipes class medium with heavy duty seamless sockets for lowering of submersible pumps including testing of joints, cost of pipes & heavy duty sockets and jointing materials all complete. Pipes and sockets confirming to IS:1239-2011 Part-II.\nPHE (03.07.2018) uSOR. Addendum order No 254 dated 06.08.2020 Item No. 17.38.1 P. 3\n(a) 50 mm dia, class medium with heavy duty seamless sockets41440mtr
55(b) 65 mm dia, class medium with heavy duty seamless sockets550mtr
66Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make.\n(a) 2.5 Sq.mm.multi strand\nPHE (03.07.2018) uSOR. Item.no. 24.20.107 (i)/p-267650mtr
77(b) 6.0 Sq.mm.multi strand\nPHE (03.07.2018) uSOR. Item.no. 24.20.107 (iii)/p-26771500mtr
88Provision for Jointing of TW to Rising Main with cost of Material/ specials such as GI Union / CI Flange, GI Reducer UPVC MTA FTA etc. as per requiement of site i/c cost of labour etc. complete as per approved specification and as directed by Engineer in charge. \nPHE (03.07.2018) uSOR. Item.no. 17.19/p-228812nos
99Provision for jointing of Rising main to supmp well/OHT and OHT to Distribution pipe line with cost of material/specials such as Bends, MTA as per rerquirement of site i/c cost of labour with excavation, labour as per requirement complete as per approved specification and as directed by Engineer in charge. PHE (03.07.2018) uSOR. Item.no. 17.20/p-229912nos
1010Supplying & Installation of Five star BEE rating ISI Marked required capacity of Three phase, 50 Hz, 415V, Open well Submersible pump, with Control Panel Starter with Dry Run Protection, single phase preventer, connections, etc. as required as per specifications but excluding pipe and connection cable.\n(a) 3.0 H.P. Head Mt.15-24, Discharge LPM 615-195\nPHE (03.07.2018) uSOR. Item.no. 24.20.113 (i) P. 268102Each
1111Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be leveled and neatly dressed.\nAll kind of soil\nPHE (03.07.2018) uSOR. Item.no. 16.4 P. 207\n(a) Rising Main Pipeline11316.8Cum
1212(b) Distribution Pipeline124224Cum
1313Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be leveled and neatly dressed. Soft rock with or without blasting or bituminous pavement / cement concrete road.\nIn ordinary or Soft rock with or without blasting or bituminous pavement / cement concrete road.\nPHE (03.07.2018) uSOR. Item.no. 16.6(a) P. 208\n(a) Rising Main Pipeline13324Cum
1414(b) Distribution Pipeline143247.2Cum
1515Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be leveled and neatly dressed. Soft rock with or without blasting or bituminous pavement / cement concrete road.\nHard rock (requiring blasting.)\nPHE (03.07.2018) uSOR. Item.no. 16.6(b ) P. 208\n(a) Rising Main Pipeline1536Cum
1616(b) Distribution Pipeline16442.8Cum
1717Installation of HDPE pipe by Horizontal Direction Drilling Method including preparing and setting up the plant and equipment, making string of new pipe material, installing new pipe string and making the system ready for commissioning by HDD operation including drilling, stringing, reaming and pulling back the new pipe on the designed bore path alignment, proper disposal of drilling fluid, as per code of practice for horizontal direction drilling technique suiting indian conditions. Required pipes/ specials and other civil work shall be paid separately-in all types of soils. (This item shall be executed only after prior permission of Superintending Engineer)\nPHE (03.07.2018) uSOR. Item.no. 16.3 P. 207\n(a) HDPE pipe of any class-90 mm outer dia171275mtr
1818(b) HDPE pipe of any class-110 mm outer dia18170mtr
1919Demolishing cement concrete manually / by mechanical means including disposal of material within 50 m lead as per direction of engineer-in- charge.\nNominal concrete 1:3:6 or richer mix ( i/c equivalent\ndesign mix )\nPHE (03.07.2018) uSOR. Item.no. 16.15.1 P. 209\n19236.4Cum
2020Providing, Laying, Jointing & field testing of HDPE pipes (High Density Polyethylene Pipes) confirming to IS 4984/14151/12786/13488 with necessary jointing material like mechanical connector of jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jack/Hydraulic Jacks/ Butt fusion machine. (50 mm & above fusion jointed &\nbelow 50mm mechanical jointed)\nPHE (03.07.2018) uSOR. Item.no. 9.1 P. 122\n(a) 90 mm dia 8 Kg/ sq.cm201200mtr
2121(b) 75 mm HDPE 6 kg/sqcm213600mtr
2222(c ) 90 mm HDPE 6 kg/sqcm228400mtr
2323110 mm HDPE 6 kg/sqcm232760mtr
2424Providing and fixing following check (non-return) valves Class-\nII, confirming to IS-778/1984 (Reaffirmed 2005) female ends,\ntested to 21.09 kg/sq.cmt.\nPHE (03.07.2018) uSOR. Item.no. 6.8 P. 89\n(a)80mm dia (Flanged)246Nos
2525Providing and laying including testing Bend 90° confirming to IS specifications\nPHE (03.07.2018) uSOR. Item.no. 9.2 P. 122\n(a)90mm dia 8 Kg/ sq.cm2520Nos
262675 mm HDPE 6 kg/sqcm2650Nos
272790 mm HDPE 6 kg/sqcm2760Nos
2828110 mm HDPE 6 kg/sqcm2815Nos
2929Providing and laying including testing Bend 45° confirming to IS specification. \nPHE (03.07.2018) uSOR. Item.no. 9.3 P. 123\n(a)90mm dia 8 Kg/ sq.cm:2910Nos
303075 mm HDPE 6 kg/sqcm3020Nos
313190 mm HDPE 6 kg/sqcm3130Nos
3232110 mm HDPE 6 kg/sqcm3210Nos
3333Providing and laying including testing Equal Tee confirming to IS specification \nPHE (03.07.2018) uSOR. Item.no. 9.3 P. 123\n(a)90mm dia 8 Kg/ sq.cm:3315Nos
343475 mm HDPE 6 kg/sqcm3430Nos
353590 mm HDPE 6 kg/sqcm3550Nos
3636110 mm HDPE 6 kg/sqcm3615Nos
3737Providing and laying including testing Reducer: confirming to IS specifications.\nPHE (03.07.2018) uSOR. Item.no. 9.6 P. 124\n(a)90 mm HDPE 6 kg/sqcm3730Nos
3838110 mm HDPE 6 kg/sqcm3815Nos
3939Providing and laying including testing End Cap confirming to IS specifications.\nPHE (03.07.2018) uSOR. Item.no. 9.8 P. 124\n(a)75 mm HDPE 6 kg/sqcm3915Nos
404090 mm HDPE 6 kg/sqcm4015Nos
4141110 mm HDPE 6 kg/sqcm418Nos
4242Providing & laying mechanically mixed cement concrete 20mm nominal size graded crushed stone excluding cost of centering & shuttering. 1:2:4 (M-15)\nPHE (03.07.2018) uSOR. Item.no. 16.23 (a) II/210\n(a)Rising Main Pipeline4232.4Cum
4343Distribution Pipeline43204Cum
4444Filling available excavated earth in trenches, lead up to 50m and lift up to 1.5m in all kind of soil excluding watering and ramming.\nPHE (03.07.2018) uSOR. Item.no. 16.10 (b) P. 208\n(a)Rising Main Pipeline44640.8Cum
4545Distribution Pipeline458209.2Cum
4646Providing & fixing of following Ductile iron double flanged sluice valves as per I.S.:14846-2000 fitted with cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete\nPHE (03.07.2018) uSOR. Item.no. 4.41 P. 71\n(a)80 mm dia (CLASS PN-16)464Each
4747100 mm dia (CLASS PN-16)474Each
4848Providing & fixing of following Cast iron double flanged sluice valves as per I.S.:14846-2000 fitted with cast iron cap including jointing & testing with cost of jointing material such as bolts, nuts, rubber insertions etc. all complete\nPHE (03.07.2018) uSOR. Item.no. 8.1 P. 111\n(a)80 mm dia (PN-1.0)487Each
4949100 mm dia (PN-1.0)499Each
5050125 mm dia (PN-1.0)504Each
5151Providing and laying in position including testing following cast iron flanged spigot (tail piece)\nPHE (03.07.2018) uSOR. Item.no. 3.11/36\n(a)80mm Dia Medium Class514Each
5252100mm Dia Medium Class524Each
5353Construction of Brick masonry valve chamber with 20 cm thick wall in 1:6 C.M. with 12mm thick 1:4 Cement Plaster and base course 10 cm. thick in M-15. Inside Dimensions 110x80x100cm with - M-20 RCC chamber cover size 150cm x 120cm x 12cm including cost of materials, labour etc. complete.\nPHE (03.07.2018) uSOR. Addendum order No 254 dated 06.08.2020 Item No. 17.45.1 Page 075320Each
5454Providing & fixing following cast iron double acting air valves, flanged without inbuilt isolating valve as per IS : 14845-2000 including jointing & testing with cost of jointing material and rubber insertion all complete as per IS :13095-1991\nPHE (03.07.2018) uSOR. Item.no. 8.12/115\n(a)100 mm dia (PN-1.0)544Each
5555Design, drawing, construction, testing and commissioning of GSR/Sumpwell of following capacities with all necessary fitting and accessories as mentioned in the relevant chapter of USOR, IS codes and departmental circulars. Complete turn key job for following capacities :-\nPHE (03.07.2018) uSOR. Addendum order No 254 dated 06.08.2020 Item N 26.2 P. 17\n(a)30 KL (Item No. 26.2.2 Page 17)551No
565640 KL (Item No. 26.2.3 Page 17)561No
5757Design and Construction of RCC framed brick masonry pump house over the sump with all necessary fitting and requirement as mentioned in relevant chapter of USOR, IS codes and departmental guidelines. Complete turn key job. This item will only be used with item no 26.2 only in cases where pumphouse to be constructed above the proposed sumpwell.\nPHE (03.07.2018) uSOR. Addendum order No 254 dated 06.08.2020 Item No. 26.3/18572No
5858Design, drawing, construction, testing and commissioning of Elevated Service Reservoir/ Over Head Tank (ESR/OHT) with all necessary fitting as mentioned in relevant chapter of USOR, IS codes and departmental guidelines. Complete turn key job for following capacities with 9/12/15 meter staging height from GL :- PHE (03.07.2018) uSOR. Addendum order No 254 dated 06.08.2020 Item No. 26.1 P. 14 & 15\n(a)100 Kilo Litres Staging Height 12 Mt. Meter (Item No. 26.1.3 Page 14)581No
5959125 Kilo Litres Staging Height 12 Mt. Meter (Item No. 26.1.4 Page 14)591No
6060Providing and making Consumer Service Connection (Functional House Hold Taps Connection) from HDPE pipe with the help of electro fusion machine including all labour and material such as Electro fusion Saddle, brass ferrule (Not less than 100 gm in weight)/MDPE ferrule/flow control valve, double compression elbow, male/female threaded adopter with metal insert, sockets, MDPE union 20mm dia/GI union 15 mm dia (medium class), brass/SS tap etc all complete and all items/fittings shall be complying with the relevant BIS Codes. Rates also include excavation, cutting of road if required, refilling the trenches and restoration of road with minimum M-20 (1:1.5:3) grade CC or equivalent grade of existing CC cutting for providing tap connection (whichever is richer), construction of Platform and grouting of circular post neat finished as per the drawing attached, testing all complete items\n(a)For connection with 20 mm dia MDPE pipe upto 5 meter and CONCRETE ROAD CROSSING is necessary.\nPHE (03.07.2018) uSOR. Addendum order No 254 dated 06.08.2020 Item No. 17.41.1 Page 0460362Each
6161For connection with 20 mm dia MDPE pipe more than 5 meter & upto 10 meter and CONCRETE ROAD CROSSING is necessary.\nPHE (03.07.2018) uSOR. Addendum order No 254 dated 06.08.2020 Item No. 17.41.2 Page 0461310Each
6262For connecrion with 20 mm dia MDPE pipe upto 5 meter and road crossing is not required. (Distribution pipe line is on the same side of house) PHE (03.07.2018) uSOR. Addendum order No 254 dated 06.08.2020 Item No. 17.41.3 Page 0562155Each
6363For connection with 20 mm dia MDPE pipe more than 5 meter & upto 10 meter and road (OTHER THAN CONCRETE ROAD) crossing is necessary. PHE (03.07.2018) uSOR. Addendum order No 254 dated 06.08.2020 Item No. 17.41.4 Page 0563104Each
6464For connection with 20 mm dia MDPE pipe upto 5 meter and road (OTHER THAN CONCRETE ROAD) crossing is necessary. PHE (03.07.2018) uSOR. Addendum order No 254 dated 06.08.2020 Item No. 17.41.5 Page 0564102Each
6565Fabrication, providing and fixing of typical information board of size 2.40 m x 1.80 m made out as detailed below -\n1. Three vertical support made out from 1OO mm x 50 mm, 6.0 mm thick channel. This shall be minimum 1.0 m below GL and 3.00 m above GL. The Channel shall be erected on 600 mm x 600 mm x 1000 mm foundation blocks at appropriate depth made of cement concrete 1:2:4.\n2. The board shall be fabricated from 1.6 mm thick MS sheet of size 2.40 m x 1.80 m, The frame of board shall be fabricated with 50 mm x 50 mm x 5 thick angle with one horizontal additional support in center with same angle.\n3. Whole structure shall be painted by standard color with lettering border, heading and logo etc using synthetic enamel paint of superior quality including welding, excavation, concreting , painting of base, border and lettering, painting and other required details etc complete as directed by Engineer in charge. PHE (03.07.2018) uSOR. Addendum order No 254 dated 06.08.2020 Item No 17.47 Page 07652Job
6666Providing, placing and installation of polyethylene water tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and the base support for tank on tenace (at all floor level).\nPHE (03.07.2018) uSOR. Addendum order No 254 dated 06.08.2020 Item No. 17.36 Page 036626000Per Ltr
6767Providing laying and jointing of following galvanized Iron (MS) Pipes with specials (such as bends, elbows, tees etc) class light, medium & heavy including testing of joints, cost of pipes, specials and jointing materials all complete. Pipes and sockets\nconforming to IS-1239/2011 Part-II\nPHE (03.07.2018) uSOR. Item.no. 6.1 (a) P. 86\n(a) 25 mm Dia. G.I. Class medium671450R.M.
6868(b ) 15 mm Dia. G.I. Class medium681450R.M.
6969Providing and fixing following gate (full way) valves tested to 300lbs/Sq inch or 21.00 kg/sq.cm. confirming to IS 778/1984 (Reaffirmed 2005) Class-II\nPHE (03.07.2018) uSOR. Item.no. 6.4 P. 87\n25 mm dia. (Flanged)6929each
7070Providing and fixing G. I. Union in G.I. Pipe line i/c cutting threading testing etc. complete (New work) confirming to IS 1879\nPHE (03.07.2018) uSOR. Item.no. 6.21 P. 92\n(a) 25 mm Dia. G.I. Class medium7029No.
7171Providing and fixing Tank Nipple with outer threading in G.I. Pipe line i/c cutting threading testing etc. complete confirming to IS 1879\nPHE (03.07.2018) uSOR. Item.no. 6.49 P. 103\n(a) 25 mm Dia. G.I. Class medium7129Each
7272Providing and fixing Screwed Ball valves tested to 21.09 kg/cm confirming to IS 778/1984\nPHE (03.07.2018) uSOR. Item.no. 6.19 P. 92\n(a) 15 mm Dia.7229No.
7373(b ) 25 mm Dia.7329No.
7474Providing & fixing including testing of water taps 15 mm Dia. Brass Heavy Duty\nPHE (03.07.2018) uSOR. Item.no. 6.17 P. 9274145No.
7575Construction of 1.20 cm x 1.20 cm x 0.20 m cement concrete washing platform in cement concrete 1:2:4 including excavation, centering, shuttering, cost of all the materials and labour and curing etc. complete. Including filling in 30 cm depth after removing Black cotton soil including ramming, watering etc. complete in areas of Black cotton soils.\nPHE (03.07.2018) uSOR. Item.no. 21.9 P. 2497558No.
7676Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil\nMPPWD SOR 01.08.2014 Item No. 2.6/227654.72Cum
7777Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock\nMPPWD SOR 01.08.2014 Item No. 2.7.1/227713.68Cum
7878Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire up to floor two level including all wastage etc. complete. Thermo-Mechanically Treated bars.(TMT)\nMPPWD SOR 01.08.2014 Item No. 5.16.6/68781631.95Kg
7979Reinforced cement concrete work (with 20mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and up to floor two level excluding cost of centering, shuttering, finishing and reinforcement : M 20 –Grade Concrete\nMPPWD SOR 01.08.2014 Item No. 5.2.1/657922.42Cum
8080Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters butteresses, plinth beams and string courses etc.up to plinth level.\nMPPWD SOR 01.08.2014 Item No. 5.9.2/668089.38Sqm
8181Centering and shuttering including strutting, propping etc. and removal of form for : \n(a)Lintels, beams, girders, bressumers and cantilevers.\nMPPWD SOR 01.08.2014 Item No. 5.9.5/668120.98Sqm
8282Foundations, footings, bases of columns, etc. for concrete up to plinth level.\nMPPWD SOR 01.08.2014 Item No. 5.9.1/668263.84Sqm
8383Columns, Pillars, Piers, Abutments, Posts and Struts.\nMPPWD SOR 01.08.2014 Item No. 5.9.6/668349.25Sqm
8484Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate (M 10)\nMPPWD SOR 01.08.2014 Item No. 4.1.1.4/45844.56Cum
8585Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. up to floor two level, excluding the cost of centering, shuttering and finishing :With 20mm nominal size graded stone aggregate.\nM-20 - Grade Concrete - coping \nMPPWD SOR 01.08.2014 Item No. 4.2.1.2/45852.13Cum
8686Brick Work With Well Brunt Open Bhatta, Bricks, Crushing Strength Not Less Than 25kg/sqcm and water absorpt ion not more than 20% in superstructure above plinth level and up to floor two level i/c curing etc complete. Cement Mortar 1:6 (1 cement : 6 sand)\nMPPWD SOR 01.08.2014 Item No. 6.6.2/858628.35Cum
878712 mm cement plaster of mix : 1:6 (1 cement : 6 sand) \nMPPWD SOR 01.08.2014 Item No. 13.1.2/24487364.8sqm
8888finishing walls with Acrylic smooth exterior paint of required shade: New work ( (Two or more coat applied @ 1.67 itr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm. \nMPPWD SOR 01.08.2014 Item No. 13.55.1/25088364.8Sqm
8989Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.\nMPPWD SOR 01.08.2014 Item No. 2.25/268950.92cum
9090Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil\nMPPWD SOR 01.08.2014 Item No. 2.6/22904.8cum
9191Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed. Ordinary rock\nMPPWD SOR 01.08.2014 Item No. 2.7.1/22911.2cum
9292Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire up to floor two level including all wastage etc. complete. Thermo-Mechanically Treated bars.(TMT)\nMPPWD SOR 01.08.2014 Item No. 5.16.6/6892122.74kg
9393Reinforced cement concrete work (with 20mm nominal size graded stone aggregate) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, posts and struts etc. above plinth level and up to floor two level excluding cost of centering, shuttering, finishing and reinforcement :M 20 –Grade Concrete\nMPPWD SOR 01.08.2014 Item No. 5.2.1/65931.92Cum
9494Centering and shuttering including strutting, propping etc. and removal of form for : \nFoundations, footings, bases of columns, etc. for concrete up to plinth level.\nMPPWD SOR 01.08.2014 Item No. 5.9.1/66947.2Sqm
9595Columns, Pillars, Piers, Abutments, Posts and Struts.\nMPPWD SOR 01.08.2014 Item No. 5.9.6/66956.48Sqm
9696Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : Nominal Mix -1 Cement : 3 sand : 6 graded stone aggregate (M 10)\nMPPWD SOR 01.08.2014 Item No. 4.1.1.4/45960.4Cum
9797finishing walls with Acrylic smooth exterior paint of required shade: New work ( (Two or more coat applied @ 1.67 itr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm. \nMPPWD SOR 01.08.2014 Item No. 13.55.1/250978.4Sqm
9898Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.\nMPPWD SOR 01.08.2014 Item No. 2.25/26984.22cum
9999Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer all complete.\nMPPWD SOR 01.08.2014 Item No. 10.2 page 17899300Kg
100100Painting With Synthetic enamel paint of approved brand and manufacture to give an even hade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. \nMPPWD SOR 01.08.2014 Item No. 13.68.1 page 2521009Sqm
101101Supply, delivery , erection, testing and commissioning of the micro processor based water disinfection equipment using Oligodynamic technology as per detailed specifications mentioned in the NIT . \nApproved By CE PHED Zone INDORE, Letter.no. 160 dated. 25.07.2020\n(a)Capacity 1000 LPH1012Each
102102Capacity 15000 LPH1021Each
103103Capacity 25000 LPH1031Each
104104USOR Issued by Additional Chief Engineer (works) Office of Managing Director (WZ) M.P.P.K.V.V. Co. Ltd. Indore vide his Letter No. MD/WZ/08-03/21689, Dated 22-11-2019 for year 2019-20. Provision for extension of electric power line up to tube well including installation of suitable transformer. (The material to be used and work to be executed shall be as per Schedule Ref. of MPPKVVCL USOR given below in the items. Any decrease or increase in the work/item given in the composit reference schedule item shall be payable according to the actual execution.)\nTask No. 01\nCOST SCHEDULE - C-5.2 \n11 KV TAPPING D.P.STRUCTURE ON PCC POLES \n(a)140 Kg., 8.0 Mtrs. long PCC poles\nM-050100410412Nos
105105D.C.cross- arm of ISMC channel of 100 X 50X6 mm., suitable for 8' centre \nM-050210410512Nos
106106Clamps for 140 kg PCC pole (50x6 mm Flat)\nM-050209110624Nos
10710711 KV (45KN) 16mm FRP with 25mm per KV creepage Disc Insulator Polymer M-060200710736Nos
10810811KV Strain hard ware fitting M-040421010836Nos
10910911 KV Pin insulator Polymer Composite (5KN) FRP dia 24mm M-060200210924Nos
110110Horizontal and cross bracing 8' centre M-050239511012Nos
111111Back Clamp sutiable for 140 kg. PCC pole M-050203011148Nos
112112Painted Stay set 16 mm. complete turn buckles M-050223011224Nos
113113Stay wire 7/3.15 mm. (5.5 kg.stay wire per stay set ) M-0403019113132Kgs
114114Clamps for 140 kg PCC pole (50x6 mm Flat) M-050209111424Nos
115115Stay insulator M-060103611524Nos
116116Stone Block/Pre cast block for base pedding 450x450x75mm\nP-070205611612Nos
117117Concreting of PCC pole @0.30 cmt per pole ( with Muffing) (1:3:6) P-00010111173.6Cmt.
118118Concreting of stay @ 0.2 cmt. per stay (1:3:6) P-00010031184.8Cmt.
119119Earthing Coil ( coil of 115 turns of 50 mm.dia. and 2.5 Mtrs. lead of 4.0 mm. G.I wire) M-040309611912Nos
120120Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole) M-04031731209.6Kgs
121121Red oxide paint M-12140011217.2Ltr.
122122Aluminium paint M-12140021227.2Ltr.
123123Anti climbing devices M-040301612324Nos
124124Danger Boards Enamalled Type 11KV M-050242912412Nos
125125M.S.Nuts and Bolts M-040320812572Kgs
126126Labour charges12612Per Tapping
127127Task No. 02\nCOST SCHEDULE - C-1.2\n11 KV LINE ON PCC Pole Using Rabbit Conductor Max Span 70 Mtrs IN RURAL AREA\n(a)140 Kg., 8.0 Mtrs. long PCC Poles M-05010041278.4Nos
12812811 KV 'V' cross-arms angle type (65x65x6 mm angle) \nM-05020101288.4Nos
129129Back clamps (50x6 mm flat) for 140 kg PCC Pole \nM-050203012916.8Nos
13013011 KV Top clamps angle type 65x65x6 mm\nM-05020601308.4Nos
131131Earthing Coil ( coil of 115 turns of 50 mm.dia. and 2.5 Mtrs. lead of 4.0 mm. G.I wire) M-04030961318.4Nos
13213211 KV Pin insulator Polymer Composite (5KN) FRP dia 24mm M-060200213225.2Nos
133133AAAC Conductor Rabbit with 3 % Sag M-04010131331.86Km
134134Jointing Sleeves suitable for 55 Sq. mm.Al. Eq. AAAC conductor M-04042331343.6Nos
135135Painted Stay set 16 mm. complete turn buckles M-05022301353.6Nos
136136Stay wire 7/3.15 mm. (5.5 kg.stay wire per stay set )\nM-040301913619.8KGs
137137Clamps for 140 kg PCC pole (50x6 mm Flat) M-05020911373.6set
138138Stay insulator M-06010361383.6Nos
139139Back filling of poles with boulders. M-00010011398.4Nos
140140Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole) M-04031731406.72KGs
141141Stone Block/Pre cast block for base pedding 450x450x75mm \nP-07020561418.4Nos
142142Concreting of stay @ 0.2 cmt. per stay (1:3:6) P-00010031420.72Cmt.
143143Red oxide paint M-12140011430.3Ltr.
144144Aluminium paint M-12140021440.3Ltr.
145145Anti climbing devices M-04030161458.4Nos
146146Danger Boards Enamalled Type 11KV M-05024291468.4Nos
147147M.S.Nuts and Bolts M-040320814710.8Kgs
148148Binding wire and tape M-04043701481.8Kgs
149149Labour charges1490.6Per.Km
150150Task No. 03\nCOST SCHEDULE E-1.1\n11/0.4 KV, 25KVA OUT DOOR SUB-STATION (ON PCC POLE )\n(a)DTR 11/0.4 KV BIS EE-Level-2 25 KVA M-011400415012Nos
151151140 Kg., 8.0 Mtrs. long PCC Poles M-050100415124Nos
152152D.C.cross-arm of 100 X50 X 6 mm., 8' centre M-050210415212set
153153Clamp for 8 Mtr PCC Pole Size-610 mm ,Wt- 1.46 Kg using 50X6 mm Ms Flat M-050209115324set
15415411 KV (45KN) 16mm FRP with 25mm per KV creepage Disc Insulator Polymer M-060200715436Nos
15515511KV Strain hard ware fitting M-040421015536Nos
15615611 KV D.O. fuse & Lightening Arrestor mounting channel (75X 40 X 6 mm.) M-050221015612Nos
157157Back Clamp for 8 Mtr PCC Pole Size- 448 mm ,Wt- 1.075 Kg using 50X6 mm Ms Flat M-050203015724Nos
15815811 KV D.O. fuse unit M-020114215836Nos
1591599 KV Gapless type ( 5KA) Polymer for DTR M-020110615936Nos
160160Transformer mounting DC cross-arm 100 X 50 x 6 mm, channel. M-050213116012set
161161Transformer belting with 50 X 50 X 6 mm.angle with two cross fixing channels M-050213716112set
162162Clamp for 8 Mtr PCC Pole Size-610 mm ,Wt- 1.46 Kg using 50X6 mm Ms Flat M-050209116248set
163163Stay set 16 mm. Painted complete with turn buckles \nM-050223016348Nos
164164Stay wire 7/3.15 mm. (5.5 kg.stay wire per stay set ) \nM-0403019164264Kgs
165165Stay insulator M-060103616548nos
166166Clamp for 8 Mtr PCC Pole Size-610 mm ,Wt- 1.46 Kg using 50X6 mm Ms Flat M-050209116648nos
167167Stone Block/Pre cast block for base pedding 450x450x75mm\nP-070205616724nos
168168Concreting of PCC pole @ 0.30 cmt. per pole (1:3:6)\nP-00010111687.2cum
169169Concreting of Stay @ 0.2 cmt. per stay (1:3:6) P-00010031699.6Cmt.
170170AAA Conductor Rabbit for Jumper M-04010131700.36km
171171Danger Boards Enamalled Type 11KV M-050242917112Nos
172172HT Bi-metallic Clamp for DTR M-011802217236Nos
173173LT Bi-metallic Clamp for DTR 12 mm M-011801917348Nos
174174Earthing set M-040309717412set
175175Anti climbing devices M-040301617524Nos
176176Red oxide paint M-121400117612Ltr.
177177Aluminium paint M-12140021774Ltr.
178178M.S.Nuts and Bolts M-0403208178168Kgs
179179Meter cum protection box for 16/25 KVA DTR M-030400917912Nos
18018035 Sq.mm. XLPE insulated Single core Unarmoured cable\nM-04020781801.44km
181181Three phase meter 20-80 Amps.with L.S. & TOD Facility with box M-030202818112Nos
182182Labour charges18212per km
183183Task No. 04\nCOST SCHEDULE D-2.2\n L.T. LINES 3 PHASE 5 WIRE ON PCC SUPPORTS USING 1100 Volts Grade A.B. CABLE 3 X 25 + 1 X 16 + 1 X 35 Sq.mm. XLPE WITH MAXIMUM SPAN OF 50 METERS\n(a)140 Kg.,8.0 Mtr. long PCC Support M-0501004\n18330No.
184184A.B Cable hanging clamps/ tension clamps (Galvanized) \nM-04042051849No.
185185Suspension Clamp with attachment M-040421918521No.
186186Clamp for Neutral M-040422318630No.
187187Piercing connector Type-I for single phase/three phase(Main 16-50 sq.mm. tape- of 16-50 sq.mm) M-040428218790No.
188188Piercing connector Type-II (Main 16-50 sq.mm. tape- of 16-50 sq.mm) M-040428318860No.
1891891100 Volts Grade Aerial bunched XLPE Cable 2x35+1x16+1x35 sq.mm.(insulated nuetral massenger)\nM-04021021891.58Km.
190190Stay set 16 mm. complete without stay wire (Painted)\nM-050223019018Set
191191Stay wire 7/3, 15 mm. (5.5 kg.stay wire per stay set )\nM-040301919199Kgs.
192192Clamps for 140 Kg. PCC Pole (50x6 mm flat)\nM-050209119248Set
193193Stay Insulator M-060103619318Set
194194Back filling of pole pit with boulder M-000100119430No.
195195Stone Block/Pre cast block for base pedding 450x450x75mm P-070205619530No.
196196Concreting of stay @ 0.2 cmt. per stay P-00010031963.6Cmt.
197197M S Nuts and bolts M-040320819745Kg.
198198Earthing Coil ( coil of 115 turns of 50 mm.dia. and 2.5 Mtrs. lead of 4.0 mm. G.I wire) M-04030961987.5No.
199199Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole) P-040317319924Kgs.
200200Single Phase Service connection box\n(Deep Drwan Metal Service Connection Boxes ) with one incoming up to 25 mm2 and 8 no outgoing up to 10 mm2 with insulated multiple outgoing connector- M-030407520015No.
201201Three Phase Service connection box\n(Deep Drwan Metal Service Connection Boxes ) with one incoming up to 35 mm2 and 4 no outgoing up to 16 mm2 with insulated multiple outgoing connector- M-030407620115No.
202202Labour charges2021.5per Km.

AI Tender Summary

OUR REF NO 26598427
AUTHORITY Government Departments
TENDER VALUE 2.01 Crore
LAST DATE 27-01-2021
Authority
Authority Name Public Health Engineering Department
Work Description Retrofitting Work In Different Villages Of Block Pansemal In Barwani Distt
Basic Detail
Tender No 47/20-21
Bidding Type Tender
Location
City Pansemal
State Madhya Pradesh
Key Dates
Publish Date 13 Jan 2021
Submission Date 27 Jan 2021
Open Date 29 Jan 2021
Finance
Tender Value 2.01 Crore
Tender Fee 15000
EMD 2.01 Lakhs
Exemption Not Available
Document List
Tendernotice_1.pdf
BOQ_144233.xls
22BF972B-73BD-4C4B-895C-3B5438D040D4.html
123779.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 13, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 27, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 29, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

xls

BOQ_144233.xls

html

22BF972B-73BD-4C4B-895C-3B5438D040D4.html

pdf

123779.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders