| 1 | 1 | CIVIL | BI01010001010000000000000515BI0100001112 | | |
|---|
| 2 | 1.01 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazingand false ceiling including disposal of unserviceable surplus material andstacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. | BI01010001010000000000000515BI0100001113 | 203.03 | sqm |
|---|
| 3 | 1.02 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm | BI01010001010000000000000515BI0100001114 | 149.23 | sqm |
|---|
| 4 | 1.03 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. | BI01010001010000000000000515BI0100001114 | 197.23 | sqm |
|---|
| 5 | 1.04 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved byEngineer-in-charge, beyond 50 m initial lead, for all leads including all lifts up to 10 km | BI01010001010000000000000515BI0100001114 | 19.51 | cum |
|---|
| 6 | 1.05 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead : With cement mortar 1:4 (1cement: 4 fine sand) | BI01010001010000000000000515BI0100001114 | 42.5 | sqm |
|---|
| 7 | 1.06 | Cement Plaster (in Coarse Sand) 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) | BI01010001010000000000000515BI0100001114 | 357.38 | sqm |
|---|
| 8 | 1.07 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | BI01010001010000000000000515BI0100001114 | 582.22 | sqm |
|---|
| 9 | 1.08 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | BI01010001010000000000000515BI0100001114 | 1021.1 | sqm |
|---|
| 10 | 1.09 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre | BI01010001010000000000000515BI0100001114 | 1021.1 | sqm |
|---|
| 11 | 1.1 | Distempering with 1st quality acrylic distemper, having VOC (VolatileOrganic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required,to achieve even shade and colour. Two coats | BI01010001010000000000000515BI0100001114 | 1021.1 | sqm |
|---|
| 12 | 1.11 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work | BI01010001010000000000000515BI0100001114 | 19.87 | sqm |
|---|
| 13 | 1.12 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, including grouting the joint with white cement & matching pigments etc. complete Size of Tile 600x600 mm | BI01010001010000000000000515BI0100001114 | 144.73 | sqm |
|---|
| 14 | 1.13 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm | BI01010001010000000000000515BI0100001114 | 8.26 | sqm |
|---|
| 15 | 1.14 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. With 15 mm thick tegular edged light weight calcium silicate false ceiling tiles. | BI01010001010000000000000515BI0100001114 | 140 | sqm |
|---|
| 16 | 1.15 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of : G.S. Sheet | BI01010001010000000000000515BI0100001114 | 150.35 | sqm |
|---|
| 17 | 1.16 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. Metres | BI01010001010000000000000515BI0100001114 | 12 | Each |
|---|
| 18 | 1.17 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). | BI01010001010000000000000515BI0100001114 | 6.08 | cum |
|---|
| 19 | 1.18 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. | BI01010001010000000000000515BI0100001114 | 800 | kg |
|---|
| 20 | 1.19 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers etc | BI01010001010000000000000515BI0100001114 | 41.2 | sqm |
|---|
| 21 | 1.2 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) | BI01010001010000000000000515BI0100001114 | 18 | sqm |
|---|
| 22 | 1.21 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling / self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | BI01010001010000000000000515BI0100001114 | 147.25 | sqm |
|---|
| 23 | 1.22 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete. North light curves | BI01010001010000000000000515BI0100001114 | 17 | meter |
|---|
| 24 | 1.23 | Structural steel work in single section, fixed with or without connecting\nplate,including cutting, hoisting, fixing in position and applying a priming\ncoat of approved steel primer all complete. | BI01010001010000000000000515BI0100001114 | 715 | kg |
|---|
| 25 | 1.24 | Steel work in built up tubular ( round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes | BI01010001010000000000000515BI0100001114 | 1500 | kg |
|---|
| 26 | 1.25 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work | BI01010001010000000000000515BI0100001114 | 256.6 | sqm |
|---|
| 27 | 1.26 | Providing and fixing factory made shutters of Pre-laminated particle board flat pressed three layer or graded wood particle board with one side decorative finish and other side balancing lamination conforming to IS: 12823 Grade l Type ll, of approved design, and edges sealed with water resistant paint and lipped with aluminium 'U' type edge beading allround the shutter, including fixing with angle cleat, grip strip, cadmium plated steel screws, including fixing of aluminium hinges 100x63x4 mm etc. complete as per architectural drawing and direction of Engineer-in- Charge (Cost of 'U' beading and hinges will be paid for separately). 25 mm thick | BI01010001010000000000000515BI0100001114 | 18 | sqm |
|---|
| 28 | 1.27 | Providing and fixing aluminum U beading of required size to Pre-laminated/flush door shutter, including fixing etc. complete as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001114 | 31.744 | kg |
|---|
| 29 | 1.28 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width | BI01010001010000000000000515BI0100001114 | 26 | meter |
|---|
| 30 | 1.29 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) | BI01010001010000000000000515BI0100001114 | 234.31 | kg |
|---|
| 31 | 1.3 | Providing and fixing aluminium sliding door bolts, ISI marked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm | BI01010001010000000000000515BI0100001114 | 12 | Each |
|---|
| 32 | 1.31 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm | BI01010001010000000000000515BI0100001114 | 7 | Each |
|---|
| 33 | 1.32 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm | BI01010001010000000000000515BI0100001114 | 20 | Each |
|---|
| 34 | 1.33 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper | BI01010001010000000000000515BI0100001114 | 6 | Each |
|---|
| 35 | 1.34 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. | BI01010001010000000000000515BI0100001114 | 6 | Each |
|---|
| 36 | 1.35 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : Of sectional area 40 square centimetres and above | BI01010001010000000000000515BI0100001114 | 4 | cum |
|---|
| 37 | 1.36 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. | BI01010001010000000000000515BI0100001114 | 3.14 | cum |
|---|
| 38 | 1.37 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar | BI01010001010000000000000515BI0100001114 | 4 | cum |
|---|
| 39 | 1.38 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) | BI01010001010000000000000515BI0100001114 | 1.5 | cum |
|---|
| 40 | 1.39 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand) | BI01010001010000000000000515BI0100001114 | 20 | sqm |
|---|
| 41 | 1.4 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. | BI01010001010000000000000515BI0100001114 | 20 | sqm |
|---|
| 42 | 1.41 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge. Pre-laminated particle board with decorative lamination on both sides | BI01010001010000000000000515BI0100001114 | 11 | sqm |
|---|
| 43 | 1.42 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately), Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) | BI01010001010000000000000515BI0100001114 | 10.58 | kg |
|---|
| 44 | 1.43 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces | BI01010001010000000000000515BI0100001114 | 2.76 | sqm |
|---|
| 45 | 1.44 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge. Pre-laminated particle board with decorative lamination on both sides | BI01010001010000000000000515BI0100001114 | 11.2 | sqm |
|---|
| 46 | 1.45 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) | BI01010001010000000000000515BI0100001114 | 10 | sqm |
|---|
| 47 | 1.46 | Providing and fixing acrylic sheet of 5 mm thickness of approved quality as per instruction of Engineer-in-charge. | BI01010001010000000000000515BI0100001114 | 46.44 | sqm |
|---|
| 48 | 1.47 | Dismantling tile work up to 10 to 25mm thickness on wall laid in cement mortar, Polymmer modified motar including stacking material within 50 metres lead. | BI01010001010000000000000515BI0100001114 | 4.95 | sqm |
|---|
| 49 | 1.48 | Providing and fixing Ist quality rectified ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete | BI01010001010000000000000515BI0100001114 | 4.95 | sqm |
|---|
| 50 | 1.49 | Taking away the dismantelled precoated galvanised iron profile sheets to contractor's own godown/dumpyard including loading, unloading etc. complete as per direction. The quoted amount to be paid by conttractor or to be recovered from contractor as per actual quantity measured based on quoted rate. | BI01010001010000000000000515BI0100001114 | 150.35 | sqm |
|---|
| 51 | 1.5 | Taking away the dismantelled Wooden truss to contractor's own godown/dumpyard including loading, unloading etc. complete as per direction. The quoted amount to be paid by conttractor or to be recovered from contractor as per actual quantity measured based on quoted rate | BI01010001010000000000000515BI0100001114 | 4 | cum |
|---|
| 52 | 2 | ELECTRICAL | | | |
|---|
| 53 | 2.01 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C | BI01010001010000000000000515BI0100001114 | 65 | Point |
|---|
| 54 | 2.02 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. Mm | BI01010001010000000000000515BI0100001114 | 360 | meter |
|---|
| 55 | 2.03 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4 sq. Mm | BI01010001010000000000000515BI0100001114 | 210 | meter |
|---|
| 56 | 2.04 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 6 Sq.mm | BI01010001010000000000000515BI0100001114 | 162 | meter |
|---|
| 57 | 2.05 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25mm | BI01010001010000000000000515BI0100001114 | 385 | meter |
|---|
| 58 | 2.06 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm | BI01010001010000000000000515BI0100001114 | 255 | meter |
|---|
| 59 | 2.07 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm | BI01010001010000000000000515BI0100001114 | 60 | meter |
|---|
| 60 | 2.08 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch | BI01010001010000000000000515BI0100001114 | 90 | Each |
|---|
| 61 | 2.09 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet | BI01010001010000000000000515BI0100001114 | 90 | Each |
|---|
| 62 | 2.1 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) | BI01010001010000000000000515BI0100001114 | 45 | Each |
|---|
| 63 | 2.11 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm) | BI01010001010000000000000515BI0100001114 | 45 | Each |
|---|
| 64 | 2.12 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable | BI01010001010000000000000515BI0100001114 | 600 | meter |
|---|
| 65 | 2.13 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole | BI01010001010000000000000515BI0100001114 | 30 | Each |
|---|
| 66 | 2.14 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole | BI01010001010000000000000515BI0100001114 | 10 | Each |
|---|
| 67 | 2.15 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. | BI01010001010000000000000515BI0100001114 | 12 | Each |
|---|
| 68 | 2.16 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness | BI01010001010000000000000515BI0100001114 | 20 | meter |
|---|
| 69 | 2.17 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. | BI01010001010000000000000515BI0100001114 | 20 | Each |
|---|
| 70 | 2.18 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double Door | BI01010001010000000000000515BI0100001114 | 1 | Each |
|---|
| 71 | 2.19 | Supplying, Installation, commissioning & testing of ceiling fan 1200 mm, BEE 5 Star rated without regulator including wiring the down rod with 1.5 sqmm PVC insulated copper wire single core cable complete as reqd. (Crompton Greaves HS Plus 48-inch 53-Watt Power Saver Ceiling Fan (White) or equivalent make Crompton Greaves, Bajaj, Havells) | BI01010001010000000000000515BI0100001114 | 26 | Each |
|---|
| 72 | 2.2 | Supplying, Installation, Testing and Commisioning of recessed Mounting LED flat panel 2' x 2' fabricated CRCA sheet steel housing duly powder coated with high efficient LEDs & glare free opal diffuser, IP20 min 36 watt complete in false ceiling with driver (constant current and constant voltage) complete in every way as required. (Halonix CAT Ref. No. HLFPR22-02-36-CW-R-HL1 or its equivalent) | BI01010001010000000000000515BI0100001114 | 31 | Each |
|---|
| 73 | 2.21 | Supplying, Installation, Testing and Commisioning of aesthetically designed rectangular surface/pendant luminaire, duly powder coated housing made of Aluminium extrusion section and opal diffuser, IP20 min 36 watt complete in every way as required. (Halonix CAT Ref. No. HLLL-P04-36-CW-AL or its equivalent) | BI01010001010000000000000515BI0100001114 | 19 | Each |
|---|
| 74 | 2.22 | Removing/ Relocation/ Installation of existing split type air conditioning unit up to 2 TR capacity and providing MS supporting stand, power cable of 3 core x 2.5 Sq. mm, refrigerant copper piping of 5/8” and 1/4” size with 9 mm thick insulation and 25mm PVC drain pipe upto 6 metres, gas charging etc. for the split AC unit complete in all respects. | BI01010001010000000000000515BI0100001114 | 5 | Each |
|---|
| 75 | 2.23 | Dismantling of various sizes of steel conduit along with accessories fixed on surface and taking away the same to contractors own godown/dumpyard including loading, unloading etc. complete as per direction of Engineer in charge. | BI01010001010000000000000515BI0100001114 | 550 | meter |
|---|
| 76 | 2.24 | Supplying and fixing of CAT 6 information outlet (I/O) for data, voice rack end complete with feruling and end termination as required.(Make:-(Belden/Legrand-Myrius/MK/Schnider/Crabtree) | BI01010001010000000000000515BI0100001114 | 45 | Each |
|---|
| 77 | 2.25 | Supplying and fixing one module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | BI01010001010000000000000515BI0100001114 | 26 | Each |
|---|
| 78 | 2.26 | Supplying and fixing following size/ modules, PVC box alongwith modular base & cover plate for modular switches in recess etc. as required. (To be fixed on existing table) 6 Module (200 mmX75 mm) | BI01010001010000000000000515BI0100001114 | 18 | Each |
|---|
| 79 | 2.27 | Supplying and laying of 25mm, flexible PVC conduit pipe as required. (To be fixed from floor box) | BI01010001010000000000000515BI0100001114 | 30 | meter |
|---|
| 80 | 2.28 | Supplying, laying and fixing of floor box of galvanised steel with cover. The floor box shall be blank with earthing clamp and should have provison of pulling out cables and wires as required. | BI01010001010000000000000515BI0100001114 | 3 | Each |
|---|