| 1 | 1 | DSR Item No. 14.15 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. | | | |
|---|
| 2 | 1.01 | 63 mm dia (OD-63 mm & ID-51 mm nominal) | | 650 | P. Mtr. |
|---|
| 3 | 2 | DSR Item No. 7.5 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. | | | |
|---|
| 4 | 2.01 | Upto 35 sq. mm | | 500 | P. Mtr. |
|---|
| 5 | 3 | DSR Item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator) | | | |
|---|
| 6 | 3.01 | 4 way (4 + 12), Double door | | 1 | Each |
|---|
| 7 | 4 | DSR Item No. 2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) | | | |
|---|
| 8 | 4.01 | 4 way (4 + 12), Double door | | 1 | Each |
|---|
| 9 | 5 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | | | |
|---|
| 10 | 5.01 | Triple pole | | 1 | Each |
|---|
| 11 | 5.02 | Single pole | | 21 | Each |
|---|
| 12 | 5.03 | Triple pole and neutral | | 1 | Each |
|---|
| 13 | 6 | DSR Item No. 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. | | | |
|---|
| 14 | 6.01 | 125 A, 16 KA,TPMCCB | | 1 | Each |
|---|
| 15 | 7 | DSR Item No. 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | | | |
|---|
| 16 | 7.01 | 4 x 6 sq. mm | | 20 | P. Mtr. |
|---|
| 17 | 8 | DSR Item No. 5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. | | 2 | Each |
|---|
| 18 | 9 | DSR Item No. 5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. | | 6 | P. Mtr. |
|---|
| 19 | 10 | Supply erection testing & commissioning of earth embedded 4 watt LED fitting outdoor type 2700 to 3000 K, IP 66. Make The fitting shall be installed after removing the old defective fitting including disconnections etc. (As per Complete Item No. 10 of the DNIT). | | 59 | Each |
|---|
| 20 | 11 | S/E of thermoplastic cable junction box outdoor type IP 66 with knockouts for cable entry and of minimum size 200 X 160 X 98 mm deep comprising of 1 No. 6 amps SP MCB, 10 KA, C-Curve, 1 No. 4 way epoxy cast resin cable terminal block of 30 amps capacity in the cement collar after removing the old unserviceable damaged junction box by proper cashing & fixing the box with cement sand mixture. (As per Complete Item No. 11 of the DNIT). | | 50 | Each |
|---|
| 21 | 12 | Supply and erection of sheet metal cubical pedestal of suitable dimensions made from 50 mm X 50 mm X 6 mm thick M.S angle iron frame, covered with 16 gauge thick M.S. sheet duly. (As per Complete Item No. 12 of the DNIT). | | | |
|---|
| 22 | 12.01 | Cubical size 1200 mm X 900mm X 350 mm | | 1 | Each |
|---|
| 23 | 13 | Supply, Erection, Testing & Commissioning of 120 Watt LED Flood Light fitting complete with pressure die cast aluminum housing, Electronic LED Driver Power supply & related accessories with the following specifications to be installed in existing MS cage. (As per Complete Item No. 13 of the DNIT). | | 4 | Each |
|---|
| 24 | 14 | Supply & erection of 9 watt LED lamp in existing RCC bollard after removing the existing CFL lamp. The lamp shall be of Phillips/ Wipro/ Osram make only. The job includes all labour and other petty material required to complete the job to the entire satisfaction of the E.I.C. of the work. | | 50 | Each |
|---|
| 25 | 15 | Supply & erection of backlite holder in existing RCC bollard after removing the old defective BL holder with suitable arrangements. The make of the holder shall be Anchor/ SSK/Kinjal. The job includes all labour and other petty material required to complete the job to the entire satisfaction of the E.I.C. of the work. | | 50 | Each |
|---|
| 26 | 16 | Supply, erection, testing & commissioning of surface mounted LED brick light of minimum dimension 150 mm in length, IP 54 aluminum PC, Colour temperature 3000 K, Beam angle 95 to 98 degree. (As per Complete Item No. 16 of the DNIT). | | 1 | Each |
|---|