| 1 | 1 | PART - A : | item1 | | |
|---|
| 2 | 1.01 | Daily operation & maintenance of all electrical installations under scope of work including day to day switching ON/OFF of street lights, Verification & reporting to CIDCO the status, healthyness, checking connections, wiring, earthing complete for proper functioning of all electrical installation & its accessories. \nThe work includes: \na) Reporting the faults, breakdowns, preventive measures, repairs & maintenance and all safety measures, \nb) Recording the reading of MSEDCL energy meter & other measuring devices, obtaining the MSEDCL monthly energy bills, Co-ordination with CIDCO's concerned dept. & MSEDCL for obtaining payment of MSEDCL bills from CIDCO and timely payment to MSEDCL, obtaining receipts. \nc) Monitoring Power Factor & Maintaining it above 0.95, \nd) Co-ordination with various departments/ statutory bodies for monitoring the progress of the work. \ne) Co-ordination and follow-up with MSEDCL for maintaining power supply to electrical installations.\nMinimum Manpower - Supervisor =1, Operator =9 Nos, Helper =1, fitter = 1 nos.\n | item2 | 365 | Per Day |
|---|
| 3 | 2 | PART - B : | item3 | | |
|---|
| 4 | 2.01 | Pump Set Spares | item4 | | |
|---|
| 5 | 2.02 | Supply, erection, testing and commissioning of (40HP) Horizontal pump set spares with their MOC: | item5 | | |
|---|
| 6 | 2.03 | i) Impeller-CF8M | item6 | 1 | No |
|---|
| 7 | 2.04 | ii) Shaft sleev -SS410. | item7 | 2 | No |
|---|
| 8 | 2.05 | iii) Shaft-SS | item8 | 2 | No |
|---|
| 9 | 2.06 | iv) Check Nut-SS | item9 | 2 | No |
|---|
| 10 | 2.07 | v) Wear ring- SS | item10 | 2 | No |
|---|
| 11 | 2.08 | vi) Lantern Ring-SS | item11 | 2 | No |
|---|
| 12 | 2.09 | viii) Gland packing | item12 | 2 | No |
|---|
| 13 | 2.1 | ix) 'O' Ring-Rubber | item13 | 2 | No |
|---|
| 14 | 2.11 | x) bearing-SS | item14 | 2 | No |
|---|
| 15 | 2.12 | xi) Liquid Deflector-Rubber | item15 | 2 | No |
|---|
| 16 | 2.13 | xii) servicing and complete overhauling | item16 | 2 | Job |
|---|
| 17 | 2.14 | Supply ,erection ,testing and commissioning of (80HP) Horizontal pump set spares with their MOC: | item17 | | |
|---|
| 18 | 2.15 | i) Impeller-CF8M | item18 | 1 | No |
|---|
| 19 | 2.16 | ii) Shaft sleev -SS410. | item19 | 2 | No |
|---|
| 20 | 2.17 | iii) Shaft-SS | item20 | 2 | No |
|---|
| 21 | 2.18 | iv) Check Nut-SS | item21 | 2 | No |
|---|
| 22 | 2.19 | v) Wear ring- SS | item22 | 2 | No |
|---|
| 23 | 2.2 | vi) Lantern Ring-SS | item23 | 2 | No |
|---|
| 24 | 2.21 | viii) Gland packing | item24 | 2 | No |
|---|
| 25 | 2.22 | ix) 'O' Ring-Rubber | item25 | 2 | No |
|---|
| 26 | 2.23 | xi) Liquid Deflector-Rubber | item26 | 2 | No |
|---|
| 27 | 2.24 | xii) servicing and complete overhauling | item27 | 2 | Job |
|---|
| 28 | 2.25 | Supply, erection, testing and commissioning of (80HP) Submersible pump set spares with their MOC: | item28 | | |
|---|
| 29 | 2.26 | i) overhauling & servicing. | item29 | 2 | No |
|---|
| 30 | 2.27 | ii) bearing -7220B | item30 | 2 | No |
|---|
| 31 | 2.28 | ii) bearing -6216 | item31 | 2 | No |
|---|
| 32 | 2.29 | iii) Mechanical seal (upper) | item32 | 2 | No |
|---|
| 33 | 2.3 | iv) Mechanical seal (lower) | item33 | 2 | No |
|---|
| 34 | 2.31 | v) Super Oil | item34 | 15 | Ltr |
|---|
| 35 | 2.32 | vi) 'O' Ring -Rubber | item35 | 2 | No |
|---|
| 36 | 2.33 | vii) Removing & lifting job | item36 | 2 | No |
|---|
| 37 | 2.34 | viii) Transporting charges. | item37 | 2 | No |
|---|
| 38 | 2.35 | Supply, erection, testing & commissioning of 25HP VT pump spares with their MOC. | item38 | | |
|---|
| 39 | 2.36 | i) pump shaft-ss | item39 | 1 | No. |
|---|
| 40 | 2.37 | ii)pump shaft sleeve-ss | item40 | 3 | No. |
|---|
| 41 | 2.38 | iii) pump impeller-CFM8 | item41 | 2 | No. |
|---|
| 42 | 2.39 | iv) pump impellar key-SS | item42 | 3 | No. |
|---|
| 43 | 2.4 | v) pump bearing -SS | item43 | 2 | No. |
|---|
| 44 | 2.41 | vi) check nut-SS | item44 | 3 | No. |
|---|
| 45 | 2.42 | vii) water seal-Rubber | item45 | 3 | No. |
|---|
| 46 | 2.43 | viii) stud -SS | item46 | 3 | No. |
|---|
| 47 | 2.44 | ix) gland packing | item47 | 3 | No. |
|---|
| 48 | 2.45 | x) coupling | item48 | 1 | No. |
|---|
| 49 | 2.46 | xi) Rubber Spider | item49 | 2 | No. |
|---|
| 50 | 2.47 | xii) servicing & overhauling | item50 | 2 | Job |
|---|
| 51 | 2.48 | Supply, erection, testing & commissioning of 50HP VT pump spares with their MOC | item51 | | |
|---|
| 52 | 2.49 | i) pump shaft -SS | item52 | 2 | No. |
|---|
| 53 | 2.5 | ii) shaft sleeve -SS | item53 | 2 | No. |
|---|
| 54 | 2.51 | iii) impeller CF8M | item54 | 1 | No. |
|---|
| 55 | 2.52 | iv) impeller key-SS | item55 | 2 | No. |
|---|
| 56 | 2.53 | v) bearing set.-SS | item56 | 2 | No. |
|---|
| 57 | 2.54 | vi) bearing check nut-SS | item57 | 2 | No. |
|---|
| 58 | 2.55 | vii) packing set | item58 | 2 | No. |
|---|
| 59 | 2.56 | viii) water seal | item59 | 2 | No. |
|---|
| 60 | 2.57 | ix) stud -SS | item60 | 2 | No. |
|---|
| 61 | 2.58 | x) impeller check nut -SS | item61 | 2 | No. |
|---|
| 62 | 2.59 | xi) gland packing -Rubber | item62 | 2 | No. |
|---|
| 63 | 2.6 | xii) coupling -SS | item63 | 1 | No. |
|---|
| 64 | 2.61 | xiii) Rubber Spider | item64 | 2 | No. |
|---|
| 65 | 2.62 | ix) servicing & overhauling | item65 | 2 | Job |
|---|
| 66 | 2.63 | Supply, erection, testing & commissioning of 75 HP vertical turbine pump with their MOC. | item66 | | |
|---|
| 67 | 2.64 | ii) Impeller lock nut FG200 | item67 | 3 | No. |
|---|
| 68 | 2.65 | iii) Pump shaft ss | item68 | 1 | No. |
|---|
| 69 | 2.66 | iv) Shaft Sleeve -SS | item69 | 3 | No. |
|---|
| 70 | 2.67 | v) Impeller Ring -SS | item70 | 2 | No. |
|---|
| 71 | 2.68 | vi) Bearing house FG200 | item71 | 1 | No. |
|---|
| 72 | 2.69 | vii) Bearing bush-SS | item72 | 1 | No. |
|---|
| 73 | 2.7 | ix) gland packing-Rubber | item73 | 3 | No. |
|---|
| 74 | 2.71 | x) servicing & overhauling | item74 | 3 | No. |
|---|
| 75 | 2.72 | Supply, erection, testing & commissioning of 150 HP vertical turbine pump with their MOC. | item75 | | |
|---|
| 76 | 2.73 | ii) Impeller lock nut FG200 | item76 | 3 | No. |
|---|
| 77 | 2.74 | iv) Shaft Sleeve -SS | item77 | 3 | No. |
|---|
| 78 | 2.75 | v) Impeller Ring -SS | item78 | 2 | No. |
|---|
| 79 | 2.76 | ix) gland packing-Rubber | item79 | 3 | No. |
|---|
| 80 | 2.77 | x) servicing & overhauling | item80 | 3 | No. |
|---|
| 81 | 2.78 | Supply, Erection, testing & commissioning of motor after carring out Rewinding of all types of Motor (F class insulation only) including to and fro transport from work shop to site | item81 | 200 | Hp |
|---|
| 82 | 2.79 | Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. | item82 | 100 | Kg |
|---|
| 83 | 3 | Substation items | item83 | | |
|---|
| 84 | 3.01 | Supplying and erecting approved make 11 kV outdoor type gang operated air break, triple pole switch 400 A capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of \"C\" class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp. | item84 | 1 | Set |
|---|
| 85 | 3.02 | Supplying and erecting approved make, 11 kV outdoor type drop out fuse with insulator complete with fuse holders, fuse barrel with metal fitting, fuse element mounted on M.S. channel with working current of 15A capacity complete erected on provided cross arm. | item85 | 3 | Set |
|---|
| 86 | 3.03 | Supplying and erecting 11 kV fuse barrel with metal fittings complete. | item86 | 10 | Each |
|---|
| 87 | 3.04 | Supplying and erecting hard drawn copper solid wire no. 0 to 6 SWG complete erected for connections on H.T. sides | item87 | 10 | Kg |
|---|
| 88 | 3.05 | Supplying and erecting extra thick alkathene pipe 10 mm dia. erected to enclose bare conductor wires complete.. (use shall be restricted to H.T.) | item88 | 50 | Mtr |
|---|
| 89 | 3.06 | Supplying operating rod, suitable for 11/22 kV supply with clamps for removing drop out fuses at 6 meters length, 4 pieces each with rain shade with hand grip including earthling chain 1.5 m complete.(Light duty) | item89 | 3 | Each |
|---|
| 90 | 3.07 | Supplying and erecting clamps, made out of 25x3 mm, copper strips to be fixed to tubular bus for connecting the bare copper wire to other equipment, with brass nuts bolts of suitable dia complete. | item90 | 10 | Each |
|---|
| 91 | 3.08 | Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete. | item91 | 3 | Each |
|---|
| 92 | 3.09 | Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer | item92 | 3 | Per pair |
|---|
| 93 | 3.1 | Transportation of 11/22 kV transformer above 315 kVA to 1000 kVA without loading & unloading (for handing over to section store/ repair works only) | item93 | 100 | Per km |
|---|
| 94 | 3.11 | Inspection of faulty distribution transformer 11kV / 22kV on HV side, 415 V on LV side upto 500 kVA capacity in workshop in presence of authority by opening top cover, disconnecting HV & LV studs, tap changer connections; taking out core along with winding for inspection and carrying out necessary tests on HV, LV side, oil, tap-changer etc. checking breather, body condition etc. and submitting inspection report, test reports (oil, insulation, resistance, ratio, etc.) and quotation for repairs complete. | item94 | 1 | Each |
|---|
| 95 | 3.12 | Supplying and topping up filtered transformer oil of approved make with test certificate | item95 | 100 | Ltr |
|---|
| 96 | 4 | LT panel items | item96 | | |
|---|
| 97 | 4.01 | Supplying and erecting contactor similar to L&T make MNX series for motor starter suitable for above 30 H.P. to 40 H.P. | item97 | 2 | Each |
|---|
| 98 | 4.02 | Supplying and erecting contactor similar to L&T make MNX series for motor starter suitable for above 45 H.P. to 50 H.P. | item98 | 2 | Each |
|---|
| 99 | 4.03 | Supplying and erecting contactor similar to L&T make MNX series for motor starter suitable for 75 H.P. to 90 H.P. | item99 | 3 | Each |
|---|
| 100 | 4.04 | Supplying and erecting contactor similar to L&T make MNX series for motor starter suitable for 100 H.P. to 150 H.P. | item100 | 3 | Each |
|---|
| 101 | 4.05 | Supplying & erecting HRC fuse cartridge 415V 100A complete | item101 | 5 | Each |
|---|
| 102 | 4.06 | Supplying & erecting HRC fuse cartridge 415V 200A complete | item102 | 10 | Each |
|---|
| 103 | 4.07 | Supplying & erecting HRC fuse cartridge 415V 300A complete | item103 | 5 | Each |
|---|
| 104 | 4.08 | Supplying & erecting HRC fuse cartridge 415V 400A complete. | item104 | 1 | Each |
|---|
| 105 | 4.09 | Supplying & erecting fuse bridges with base HC type fuse links 240V 63A erected on polished wooden block complete | item105 | 1 | Each |
|---|
| 106 | 4.1 | Supplying & erecting fuse bridges with base HC type fuse links 240V 100A erected on polished wooden block complete | item106 | 1 | Each |
|---|
| 107 | 4.11 | Supplying & erecting fuse bridges with base HC type fuse links 40V 200A erected on polished wooden block complete | item107 | 1 | Each |
|---|
| 108 | 4.12 | Supplying & erecting fuse bridges with base HC type fuse links 240V 300A erected on polished wooden block complete | item108 | 1 | Each |
|---|
| 109 | 4.13 | Supplying, erecting & marking SPMCB 40A to 63A C- series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB | item109 | 1 | Each |
|---|
| 110 | 5 | Lighting Part | item110 | | |
|---|
| 111 | 5.01 | Supplying and erecting LED Street light fitting suitable for above 40W to 48W lamp, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification No . FG-ODF/FLS2. | item111 | 25 | Each |
|---|
| 112 | 5.02 | Supplying and erecting LED flood light fitting of 120W, including lamp, with PF > 0.95,class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification No FG-ODF/FLS-2 | item112 | 5 | Each |
|---|
| 113 | 5.03 | Supplying and erecting regular/ standard model ceiling fan of 900mm. sweep complete erected in position as per specification no. FG-FN/CF | item113 | 3 | Each |
|---|
| 114 | 6 | Cables | item114 | | |
|---|
| 115 | 6.01 | Supplying, erecting & terminating XLPE armoured cable 2 core 2.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU | item115 | 50 | Mtr |
|---|
| 116 | 6.02 | Supplying, erecting & terminating XLPE armoured cable 3 core 2.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU | item116 | 50 | Mtr |
|---|
| 117 | 6.03 | Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL | item117 | 50 | Mtr |
|---|
| 118 | 6.04 | Supplying, erecting & terminating XLPE armoured cable 3½ core 35 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL | item118 | 50 | Mtr |
|---|
| 119 | 6.05 | Supplying, erecting & terminating XLPE armoured cable 3½ core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm.(10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL | item119 | 50 | Mtr |
|---|
| 120 | 6.06 | Supplying, erecting & terminating XLPE armoured cable 1100 V.3½ core 185 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL | item120 | 10 | Mtr |
|---|
| 121 | 6.07 | Making trench of suitable width and depth in hard murum / tar road for laying provided LT cable of 16 sq. mm & above and covered with half round hume pipe complete as per specification no. CW-EXN-CTR | item121 | 100 | Mtr |
|---|
| 122 | 6.08 | Making trench of suitable width and depth in soft soil for laying provided LT cable of 16 sq. mm & above and covered with half round hume pipe complete as per specification no. CW-EXNCTR | item122 | 100 | Mtr |
|---|
| 123 | 6.09 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. | item123 | 2 | Mtr cube |
|---|
| 124 | 6.1 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP | item124 | 50 | Kg |
|---|
| 125 | 7 | DG set Spares | item125 | | |
|---|
| 126 | 7.01 | Supplying & erecting 12 V 180 Ah heavy duty plate type Battery with terminal wire duly charged complete suitable for DG set with warrantee for 3 years | item126 | 2 | Each |
|---|
| 127 | 7.02 | Carrying out servicing of DG set from 250 kVA to 500 kVA with/without AMF panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking V belts with necessary adjustment, checking and retightening of nut bolts including coupling bolts of engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of AVR, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator and Submit the servicing report to engineer in charge. (Non Comprehensive) as per specification no. GEN-SER-AMC | item127 | 5 | Job |
|---|
| 128 | 7.03 | Topping up new lubricating oil 15W/40 grade of approved make as per IS 13656 : 2014 | item128 | 75 | Ltr |
|---|
| 129 | 7.04 | Topping up new glycol based coolant 50/50 with operating range from 118°C to -37°C of approved make | item129 | 75 | Ltr |
|---|
| 130 | 7.05 | Supplying and erecting V-Belt of all types and lengths, adjust tension as per requirements from generator manufacturer suitable for DG set from 125 kVA to 250 kVA | item130 | 3 | Each |
|---|
| 131 | 7.06 | Supplying and erecting V-Belt of all types and lengths, adjust tension as per requirements from generator manufacturer suitable for DG set from 320 kVA to 500 kVA | item131 | 3 | Each |
|---|
| 132 | 7.07 | Supplying and erecting lub oil filter element along with sealing rings, gasket etc complete suitable for DG Set from 82.5 kVA to 250 kVA. | item132 | 3 | Each |
|---|
| 133 | 7.08 | Supplying and erecting lub oil filter element along with sealing rings, gasket etc complete suitable for DG Set from 320 kVA to 500 kVA. | item133 | 3 | Each |
|---|
| 134 | 7.09 | Supplying and erecting fuel filter along with sealing rings, gasket, primary filter and water separator etc complete suitable for DG Set from 62.5 kVA to 125 kVA | item134 | 3 | Each |
|---|
| 135 | 7.1 | Supplying and erecting fuel filter along with sealing rings, gasket, primary filter and water separator etc complete suitable for DG Set from 140 kVA to 200 kVA | item135 | 3 | Each |
|---|
| 136 | 7.11 | Supplying and erecting fuel filter along with sealing rings, gasket, primary filter and water separator etc complete suitable for DG Set from 250 kVA to 500 kVA. | item136 | 3 | Each |
|---|
| 137 | 7.12 | Supplying and erecting Air cleaner/Air filter element suitable for DG set from 50 kVA to 125 kVA | item137 | 3 | Each |
|---|
| 138 | 7.13 | Supplying and erecting Air cleaner/Air filter element suitable for DG set from 140 kVA to 200 kVA | item138 | 3 | Each |
|---|
| 139 | 7.14 | Supplying and erecting Air cleaner/Air filter element suitable for DG set from 250 kVA to 500 kVA | item139 | 3 | Each |
|---|
| 140 | 7.15 | Supplying and erecting SMPS based Battery Charger input voltage 230 V A.C. & output voltage 24 V DC, charging current 20A suitable to charge DG set Battery | item140 | 2 | Each |
|---|
| 141 | 7.16 | Supplying, erecting, testing and commissioning 4 pole power contactor 32A with coil voltage of 220/240 V suitable to operate on AV voltage for DG set. | item141 | 3 | Each |
|---|
| 142 | 8 | Piping works | item142 | | |
|---|
| 143 | 8.01 | Dismantled Items | item143 | | |
|---|
| 144 | 8.02 | Dismantling the existing W.T. fluorescent fitting / S.V./ M.V. / M.H. lamp /LED fitting from wall with brackets and making the site as original complete | item144 | 45 | Each |
|---|
| 145 | 8.03 | Dismantling the existing cables of all types & size above 10 sq mm up to 50 sq. mm. | item145 | 50 | Mtr |
|---|
| 146 | 8.04 | Dismantling the existing cables of all types & size above 50 sq.mm. | item146 | 100 | Mtr |
|---|
| 147 | 8.05 | Dismantling the existing ejecto pump with PVC pipeline | item147 | 10 | Job |
|---|