Provision Of Certain Sanctioned Minor Works And Special Repair Under Ge Utility Bathinda Mil Station

Tender Notice

26593317
Provision Of Certain Sanctioned Minor Works And Special Repair Under Ge Utility Bathinda Mil Station
Indian
Punjab
11-01-2021
04-02-2021
06-02-2021

Tender Details

provision Of Certain Sanctioned Minor Works And Special Repair Under Ge Utility Bathinda Mil Station

Key Value

Document Fees
INR 500 /-
EMD
INR 33268.00 /-
Tender Value
INR 16.64 Lakhs /-

Attachment

FileName File Description File Size
Tendernotice_1.pdf Tender Document-PROVN OF CERTAIN SANCTIONED MINOR WORKS AND SPECIAL REPAIR UNDER GE UTILITY BATHINDA MIL STATION 181.28
714E50B5-8CE3-41B7-B8C4-9C1D07AFC85F.html Tender Notice-Tender Notice 0
8527tenderj.pdf Tender Document-PROVN OF CERTAIN SANCTIONED MINOR WORKS AND SPECIAL REPAIR UNDER GE UTILITY BATHINDA MIL STATION 1035.30
BOQ_459590.xls Tender Document-PROVN OF CERTAIN SANCTIONED MINOR WORKS AND SPECIAL REPAIR UNDER GE UTILITY BATHINDA MIL STATION 306.50

Other Information

Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

BOQ Items

Name of Work: : PROVN OF CERTAIN SANCTIONED MINOR WORKS AND SPECIAL REPAIR UNDER GE UTILITY BATHINDA MIL STATION
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking out old unservicable under ground LT XLPE / PVC cable of any size from trenches / wall / roof / road / pipe / pole / DB including taking out of brick layer of cable protection complete all as specified and as directed by Engineer-in-Charge. Note :-Excavation and earth work shall be measured and paid for separately. 1140 Running Metre
2 2 Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for pipe line, cable trenches or for manholes etc not exceeding 10 sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified. 270 Cubic Metre
3 3 Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified. 154.6 Cubic Metre
4 4 Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified. \n(Note:- Punned thickness shall be considered for payment purpose) 81 Cubic Metre
5 5 Supply and laying un-reinforced precast concrete cable cover, Class LV, Type 1, Flat size 250mm x 150mm x 40mm complete all as specified. Make :- Topaz / Mehtab 6650 Each
6 6 Removing excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified. 115.4 Cubic Metre
7 7 Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 300 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) 410 Running metre
8 8 Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 16 Sqmm 4.00 core conforming to IS-7098 (Part-I -1988) complete all as specified. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) 730 Running metre
9 9 Supply and fixing in repairs Energy efficient LED street light fitting of 60 Watt seasonal LDR with RTC control with dimmable type, including No. of LED bulbs as per manufacturers instructions for lighting of 60 watt , epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 110 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, with auto cut OFF above 300 V & auto switch ON normal voltage, short circuit and over voltage protection facility for Driver should be potted with electrolytic capacitor of 105 degree also with auto cut OFF above 300 V & auto switch ON normal voltage and fitting incluing making electrical connection for cable connection all as directed by Engr-in-Charge. Make HALONIX CAT NO. HLSLD-ML04-60-CWL-DIM / WIPRO LR0260W/HPL CCMSSL60W/HAVELLS CCMSLS60W/C&S INDUS-S60W/PHILIPS CCMSSL60W/CROMPTON SMARTSL60W or equivalent cat part of makes as specified in Appendix ‘A’ approved list of makes / manufacturers here-in-after and approved by GE. Note :- Cable for connection of LED light fitting shall be measured and paid under appropriate item of BoQ. 48 Each
10 10 Supply and fixing PVC insulated stranded aluminium conductor cable sheathed of Size 4 Sqmm twin core flat, 1100 volts , connection for street light fitting from junction box to LED Fitting complete all as specified and directed by Engineer-in charge. 460 Running metre
11 11 Supply and fixing junction box ,size not less than 200mm x 160mm x 98mm, insulated type , made out with Polycarbonate with glass fiber reinforced. Cat Part No. KF5255 Make of Hensel / Siemens / GE Power / Rittal with MCB SP'C'Curve 2.5 Amp complete as per manufacturers instructions Note :-1.Manufacturer should submit routine test certificate for CJB/PJB 2.The Polycarbonate Junction Box shall be environment friendly, recyclabe, UV resistant, halogen & silicon free, anti acid & anti corrosive. 3. The Junction Box shall be rated for Degree of ingress Protection IP 66 in accordance with IEC 60529. 4.The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. 5.The Junction Box shall be complies with requirements of the standards IEC 60998 - 1, IEC 60988 - 2 - 1, IEC 60670 - 22 & IEC 60670 - 2 - 5. 6. The Junction Box color according to RAL 9011. 7.The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate . For beter safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - 2 - 11, DIN VDE 0304 Part - 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 degree Centigrade. The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechnical load shall be in accordance with EN 50298 - 98 for IK 08. 8. The rate of MCB SP'C'Curve 2.5 Amp is included in this item and nothing shall be paid extra on this account. 25 Each
12 12 Supply, installing, testing and commissioning of water cooler full stainless steel body, electric driven (single phase 230V, 50 Hz) having approx storage capacity of 80 ltr and normal cooling capacity of 40 ltr per hrs complete all as per manufacturers instructions and directed by Engineer-in-Charge. MODEL - SDL X 480 OF BLUE STAR OR EQUIVLANT MODEL OF MAKE VOLTAS / HITACHI / USHA SHRIRAM 1 Each
13 13 Supply and fixing Voltage stablizer for automatic operation, single phase naturally air cooled , copper wound, indoor type & designed for input variation between 150V - 285V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.00 KVA complete all as per manufacturers instructions and directed by Engineer-in-Charge. Make : V-Guard / AE / VINTEK ELECTRONICS (VOLINA) / POWER TECH / GODREJ / VINITEC ELECTRONIC LABORATORY (VINITEC) / BLUE LINE 1 Each
14 14 Supply, installating and testing Deep freezer, Electric driven ( single phase) ,5 Star Energy rating , with hard top double door, storage capacity 400 Liters , including all built in accessories complete all as per manufacturers instructions and directed by Engineer-in-Charge. Make:BLUE STAR / SAMSUNG / HITACHI / VOLTAS / GODREJ / DAIKAIN / LG. 3 Each
15 15 Supply, installation, testing and comissioning of Refrigerator capacity of 195 Litres,Frost free , Electric driven , 2 Star energy rating,single door type , Inverter linear compressor , ( Single phase 230V, 50 Hz) (minimum), , 230 V including all built in accessories complete all as as per manufacturers instructions and and directed by Engineer-in-Charge. Make: Samsung / HITACHI / BLUE STAR / GODREJ / DAIKAIN / VOLTAS / LG. 1 Each
16 16 Supply and fixing Voltage stablizer for automatic operation, single phase naturally air cooled , copper wound, indoor type & designed for input variation between 150V - 285V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.5 KVA complete all as per manufacturers instructions and directed by Engineer-in-Charge. Make : V-Guard / AE / VINTEK ELECTRONICS (VOLINA) / POWER TECH / GODREJ / VINITEC ELECTRONIC LABORATORY (VINITEC) / BLUE LINE 3 Each
17 17 Supply, installation, testing and comissioning of Refrigerator capacity of 310 Litres,Frost free , Electric driven , 5 Star energy rating,Double door type , ( Single phase 230V, 50 Hz) (minimum), , 230 V including all built in accessories complete all as as per manufacturers instructions and and directed by Engineer-in-Charge. Make: Samsung / HITACHI / BLUE STAR / GODREJ / DAIKAIN / VOLTAS /LG. 1 Each
18 18 Supply and fixing Voltage stablizer for automatic operation, single phase naturally air cooled , copper wound, indoor type & designed for input variation between 170V - 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA complete all as per manufacturers instructions and directed by Engineer-in-Charge. Make : V-Guard / AE / VINTEK ELECTRONICS (VOLINA) / POWER TECH / GODREJ / VINITEC ELECTRONIC LABORATORY (VINITEC) / BLUE LINE 2 Each
19 19 Material & labour for point wiring complete with 1.5 sqmm (Nominal cross sectional area) PVC insulated flame retardant low smoke un-sheathed and multistranded copper conductor cable with colour code ISI marked and including PVC concealed conduit medium quality conforming to 3537 Part-I , ISI marked and conduit fittings for switch socket combination including PVC insulated 1.5 Sqmm single core flame retardant low smoke un-sheathed and multistranded copper earth wire to common earth and connecting to earth dolly and including suitable MS sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet (ISI marked) top cover etc complete all as specified. (Cost of MS sunken box and bakelite sheet included in the rate) 2 Per Point
20 20 Material and labour socket combination flush type 5 Amps 2/3 pin multi purpose all as specified and as directed by Engineer-in-Charge 2 Each