FileName File Description File Size
BOQ_459682.xls Tender Document-BOQ 842.50
Tendernotice_1.pdf Tender Document-NIT 216.28
F3DE4724-FFE5-4FDE-9EBE-80CF5F24AC2D.html Tender Notice-Tender Notice 0
8272Tender.pdf Tender Document-Tender Documents 728.53

Other Information

Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

BOQ Items

NAME OF WORK : PROVISION OF CERTAIN E/M SANCTIONED WORKS UNDER AGE E/M NO-II OF GE (U-I) VISAKHAPATNAM.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in trenches n.exc 1.5 m wide and not exc 1.5 m depth and getting out in soft / loose soil complete all as specified and directed. 190 CUM
2 2 Returning and filling in of excavated material any type including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed. 82 CUM
3 3 Removal of surplus excavated material of any type to a distance not exceeding 50 m and depositing where directed at a level not exc. 1.5 m bove the starting point complete all as specified and directed. 108 CUM
4 4 Supply and spreading clean dry sand for cable cushioning in trenches complete all as specified and as directed.\n(Note: Punned thickness only shall be measured) 74 CUM
5 5 Supply and laying sub class 'B' bricks of old size (approved size locally available) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge\n 8300 EACH
6 6 M&L for GI pipe light grade 50 mm dia laid along road crossings / plinth protection with suitable fittings for cable protection or fixed to the pole/ Wall complete all as specified and directed by Engineer-in-Charge .\nMake : Surya Roshni Ltd / Tata / Jindal steel / Prakash 30 RM
7 7 Cutting the tar road / hard standing and excavating in trenches across the road of size not exceeding 0.45 m wide and 0.6 m depth for laying cable including making good the excavated portion by means of PCC 1:3:6 type C1 matching with the surroundings all as directed. 30 RM
8 8 Supplying, laying, testing and commissioning LT XLPE insulated , armoured heavy duty electric FRLS cable of following sizes, 1100 volts grade with stranded aluminium conductor laid in trenches / passing through pipe / duct/ road crossing /fixed on poles / walls Complete all as specified and directed.\nMAKE: Havells / Gloster / KEI Industries Ltd / Polycab / Asian Cables / Finolex\n[Note: The rate quoted shall inclusive of termination at ends with suitable aluminium lugs where required]
9 8.01 16 sqmm 4 core 500 RM
10 8.02 95 sqmm 3.5 core 240 RM
11 8.03 70 sqmm 3.5 core 300 RM
12 9 Supply, install, test and commissioning of Minimum 15 KVA/ 12 KW diesel engine driven Generating set with alternator out put Voltage 415 Volts +/- 1% at set value of 415 V at a frequency 50HZ +/- 0.5% with suitable standard control panel, all mounted in acoustic enclosure and AMF panel as per manufacturers design and specification as per approved CPCB-II norms confirming to the detailed specifications appended below :-\nMake of OEM: KOEL GREEN GENSET(M/s Kirloskar)model No \nHA294 GI or equivilant Stamford/Sudhir/Jackson 1 EACH
13 9.01 (i) ENGINE\n(a) General: Suitable four stroke compressed ignition, radiator water cooled,Turbocharged aspiration, continuous duty with 10% overload capacity for any one hour in 12 hours running, 50°C intake air temperature, CPCB-II approved Engine developing minimum 20.5 HP at 1500 RPM coupled to alternator mounted on Channel Iron base frame with in built removable fuel tank of capacity not lessthan 12 Hrs consumption capacity at 75% load or more as per manufactures reccommendation. The prime mover provided should be as per IS specifications having engine overload protection.\n(b) Air intake system : Should comprise of dry type intake air filter mounted on engine, one in number vacuum indicator mounted on intake piping.
14 9.02 (c) Exhaust System: Should comprise of one exhaust manifold, dry type, mounted on engine, one exhaust silencer which should be positioned in such a way that the exhaust gas is not sucked by the fan on the radiator, thereby affecting the cooling system. The silencer should cater to the noise level tolerance prescribed in the relevant BS/IS. The silencer should be provided with flaps it will open only when the generator is running with a provision of extended exhaust beyond the building duly supported with GI pipe 100MM dia so that exhaust gas is released out side. The complete exhaust system shall be properly supported so that entire lot of the exhaust system shall not fall on the DG Set.
15 9.03 (d) Fuel System: Should comprise of disposal type element fuel filter, pressure type fuel pump mounted on engine, non return check valve in fuel supply and drain lines, wire braided hose between filter and pump, fuel system with suitable capacity full authority electronic engine electronic governor and engine mounted actuator. The fuel tank must have proper locking arrangement with level indicator and to be integrated with base frame.
16 9.04 (e) Cooling System: Should comprise of radiator designed and tested for 50o C ambient temperature with 7 PSI pressure cap mounted on base rail. The thermostat installed in the engine coolant outlet, fresh water pump mounted on engine, fan and fan hub mounted on engine. A reservoir of 50% of radiator capacity to replenish coolant by gravity (as and when required) is also to be provided.
17 9.05 (f) Lubricating System: Should comprise of lubricating oil sump mounted on engine, gear driven lub oil pump mounted on engine, lubricating oil cooler-fresh water cooled integral with engine cool out circuit mounted on engine, oil filter lubricating with cap and lubricating oil dip stick for oil level check mounted on engine. The system should be capable of feeding lube oil to the main end & large end bearings, cam shaft, valve rocker gear and all moving parts.
18 9.06 (g) Starting System: Should comprise of suitable voltage DC electrical starter mounted on engine, with suitable maintenance free batteries -1 No of capacity 12 V DC with 75 AH to be mounted in trays (having rubber insulation) on the main frame or the capacity as per specification of manufacturer. It should have the provision to charge the battery from external sources during static condition and while running of the generator.
19 9.07 (h) AC Generator : The generator shall be horizontal and foot mounted, minimum 15 KVA, 415 Volts, 3 phase, 4 wire, 0.8 PF, 50 HZ, seperately excited, self regulated, brushless AC generator, suitable for an ambient temperature of 50° C with IP-23 enclosure class H insulation and temperature rise limited to class H as per following technical details
20 9.08 (i) Type : Brush less AC Generators\n(ii) Output rating minimum :15 KVA\n(iii) Output Voltage: 415 ± 1% under all loading conditions.\n(iv) Output frequency : 50Hz ±0.5% up to 0.8 lagging.\n(v) No of Phases: 3 phase with 01 Neutral (4 wire)\n(vi) Mounting : Horizontal foot mounted.\n(vii) Enclosure : Minimum IP-23 / Drip proof and screen protected.\n(viii) Automatic voltage regulator.\n(ix) Class of insulation-'H'\n(x) AREP exciatation system\nMake : Stamford/Leroy-Somer/Koel
21 9.09 NOTE : \nFollowing shall be deemed to be included in cost quoted :-\n1. Nessary foundation for installing the DG set and any other accessories shall be provided as per manufactures recommendation and cost of the same deemed to be included in the quoted rate.\n2. Cost of testing including arrangement of artificial load upto 110 % of rated capacity, temporary arrangement of connecting cables, decibel meter and cost of fuel & testing material shall deemed to be included in the quoted rate.
22 9.1 (j) BASE FRAME: Shall be stand by and fabricated from CRCA sheet or as recommended by the manufacturer metal which shall be suitable to mount the engine, alternator and radiator, channel width of base frame shall be adequate to accommodate anti-vibration pads.
23 9.11 (k) CONTROL PANEL: Shall be indoor type manufactured with 14/16 guage CRCA sheet and is powder coated for weather-proff and long lasting finish consisting of microprocessor power command controller, Aluminium busbars with suitable capacity with incoming/outgoing terminals, indicating lamps for 'Load ON' and 'Set Running', instrument fuses duly wired and ferruled, ACB of suitable rating with overload and short circuit protections etc. complete all as specified and directed.
24 9.12 (l) AMF PANEL: Sheet steel enclosed cubical type panel, LT 415 Volts 3 phase 50 Hz, made out of 3.15 mm thick CRCA sheet for body & 2 mm thick for partitions ,consisting of suitable rated contactors, 4 Pole 16 KA 63 A MCCB - 2 Nos ( for Mains/DG ), AMF Relay, Volt meter, ammeter with selector switches, Multifunctional Energy meter, Generator protection relay of L&T make, CTs and 3 Phase indicating lamps, timers etc all as per latest engineering practices.
25 9.13 Note :- The cost of control cables from engine Control panel to AMF panel shall be deemed to be included in the cost quoted.
26 9.14 (m) Accessories :-\n(i) 01 No standard mechanical and electrical tool box.\n(ii) Internal covered tube lights.
27 9.15 (n) Acoustic Enclosure :-\nSpecially designed to meet CPCB norms 75dBA @ 1 mtr at 75% load under free field conditions. The Acoustic enclosure is made of CRCA sheets and a structural/sheet metal base with high quality noise absorbent and fire-retardant grade acoustic insulation material (P.U.Foam) complying to IS 8183 with two point lifting handles
28 9.16 (a) Internal Lighting: Tube lights with protective mesh around it to be fitted inside the container for proper illumination.\n(b) Doors : The enclosure will be provided with suitable doors on the side and rear to enter the enclosure during operation and maintenance. All doors will be provided with lock and handles for opening/ closing the doors, retainers for holding the panel door
29 9.17 (o) Painting Scheme :\nSuperaltive fade resistant paint can last longer in through whether conditions
30 9.18 (p) Lifting/ Transportation arrangements :-\nContainer with suitable corners will be provided to lift the DG set along with container. This is suitable for road/ rail/ sea transportation.
31 9.19 (q) Trials:-\nTrials on site should be given as per load tests prescribed and all functional trials should be shown.
32 10 M & L for dismantling the LT / HT connections, earthings, controlling cables carefully from the transformer installed on plinth of 33 KV NAD yard and loading the 2.5 MVA transformer (Approx minimum weight 6675 Kg ) with crane of capacity not less than 20 tonnes and above, on to the transporting trolley vehicle complete all as directed by Engr-in-charge.\n(Note : If any damage occurs it is responsibility of contractor to make it serviceable). 2 JOB
33 11 M & L for dismantling the LT / HT connections, earthings, controlling cables carefully from the transformer installed on plinth of 33 KV Eksila yard and loading the 5 MVA transformer (Approx minimum weight 10200 Kg ) with crane of capacity not less than 20 tonnes and above, on to the transporting trolley vehicle all as directed by Engr-in-charge.\nNote : If any damage occurs it is responsibility of contractor to make it serviceable. 2 JOB
34 12 M&L for transporting the transformer 5 MVA on trolley vehicle of suitable capacity to NAD 33 KV Yard from 33 KV MRS at Eksila carefully complete all as directed by Engr-in-charge. 2 JOB
35 13 M&L for transporting the Transformer 2.5 MVA on trolley vehicle of suitable capacity to 33 KV MRS at Eksila from 33 KV MRS at NAD carefully and all as directed by Engr-in-charge. 2 JOB
36 14 M&L for unloading of 5 MVA transformer with cranes of capacity not less than 20 tonnes and above on the transporting trolley vehicle and placing it on the transformer plinth at 33 KV MRS NAD carefully and compleet all as directed by Engr-in-charge. 2 JOB
37 15 M&L for unloading of 2.5 MVA transformer with cranes of capacity not less than 20 tonnes and above on the transporting trolley vehicle and placing it on the transformer plinth at 33 KV MRS Eksila carefully and complete all as directed by Engr-in-charge. 2 JOB
38 15.01 Note : \n(i) Any damage to insulators / bushes / windings etc while in the custody of the contractor shall be made good at no extra cost to govt. The serviceability of the transformer shall be checked and shall be confirmed by the contractor before taking into his custody.\n
39 16 Comissioning and testing of the transformer including IR Test, Ratio Test, Magnetic Balance Test etc complete all as directed. 4 EACH JOB
40 17 Replacement of AVR and TRCC panel suitable for 5 MVA and 2.5 MVA Power Transformer including cubical internal connections and communication lines between AVR, RTCC and OLTC complete all as directed. 4 EACH JOB
41 18 Replacement of existing unserviceable auxiliary relays, differential relays and master tripping relay with niew digital relays and verification of operation of the same relays complete all as directed. 4 EACH JOB
42 19 M&L of supply and fixing 33 KV CT's Oil immersed out door type, 3Core , Ratio 250-150/5A for Core1 - Class 1 , 15VA , Core 2 - 5P10 Class , 15VA , Core 3 - Ratio 250-150/1A , Class PS , Vk/2 <30mA @ 500V as per existing model and capacity all as directed by Engr-in-Charge.\nNote : The rate quoted is including to dismentling of old CT set and deposite to department 3 EACH SET
43 20 Rectification of the control wiring for the transformers, installation and functional checks on the control wiring, which includes connections from RTCC panel to marshlling box, AVR to OLTC, Transformer protection devices to marshlling box and relays and tripping circuit complete all as directed. 4 EACH JOB
44 21 Supply, erect, test and commissioning of minimum 16 meter high mast system with its accessories. Mast shall be in two sections, hot dip galvanized and suitable for wind velocity 70 M/ sec as per IS 875 part 3. It shall consist of GI lantern carriage suitable for 8 luminaries symmetrically & their control gear boxes and lighting finial, double drum winch with both motor and manual operation, suspension system with SS wire rope 6mm dia (7/19 construction), trailing cable of flexible copper conductor cable 5 core 2.5sq.mm (minimum), torque limiter adjustable type & 01 No. aviation obstruction light (LED type). The mast shall have an integral power tool with reversible option installed inside the base compartment for its operation complete all as specified and as directed.\nMake : Bajaj/ Havells/ Philips\n\n 2 EACH
45 21.01 Note: \nThe rate quoted shall be inclusive of the following :\n(a) Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates & templates- complete set\n(b) Supply of control panel housing suitable control circuit for the operation of the mast made out of 3mm thick CRCA sheet, double door type with slopy canopy suitable for outdoor installation. It shall also consist of suitable control for the power tool motor -01 No with suitable switchgear and wiring from panel to light fittings with suitable copper conductor cable, glands, lugs including suitable foundation.
46 21.02 (c) Construction of suitable shallow foundation with M-20 grade concrete for the mast considering the safe soil bearing capacity at site as 10 t/m² at 2 meter depth with all material and labour \n(d) Erection and commissioning of the high mast with the help of suitable equipment. \n(e) Provision of GI pipe earthing for mast with 2.5m long 40mm dia GI Pipe including connection to mast earth terminal with 32 X 6mm GI flat with all material and labour.\nNote : The LED flood light fittings required will be measured and paid separately under relevant Schedule items.\n
47 22 Supply only LED flood light fitting with total lumen output not less than 19000 lumens, comprising of epoxy powder coated housing, enclosed with glass cover in frame (suitable wattage for efficiency not less than 95 lumens/Watt) with ingress protection IP 65/66 with and including SPD protection of capacity 10 KV in addition to built in SPD of electronic driver complete all as specified and as directed.\n(Make: CG Model No. LFLN-200-CDL/60-M or its equivalent in Havells / Philips / GE / WIPRO).\n 16 EACH
48 23 Supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size, out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on suitable size foundation with 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including horizantal busbar of aluminium strip suitable size for three phase 4 wire including the following accessories and fitted in complete all as specified and directed : - \n(a) Incoming: MCCB high breaking capacity 4 pole 415 volt 25 KA breaking cap adjustable thermal release range 200 amp – 01 No 1 EACH JOB
49 23.01 (b) Outgoing: (i) MCCB AC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 100 amp – 01 No \n(ii) MCCB AC high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal release range 63 amp – 03 Nos \n(iii) MCB SPN 20 Amps - 04 Nos \nMakes:\nMCCB/MCB : Legrand / L & T / Siemens / ABB / C & S / Schneider / GE\nVolt Meter/Ammeter : Havells / HPL / L & T / AE / Schneider / BCH
50 24 Supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size, out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on suitable size foundation with 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including horizantal busbar of aluminium strip suitable size for three phase 4 wire including the following accessories and fitted in complete all as specified and directed : - \n(a) Incoming: MCCB high breaking capacity 4 pole 415 volt 25 KA breaking cap adjustable thermal release range 160 amp – 01 No 1 EACH JOB
51 24.01 (b) Outgoing: (i) MCCB AC high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal release range 63 amp – 03 No \n(ii) MCB SPN 20 Amps - 03 Nos \nMakes:\nMCCB/MCB : Legrand / L & T / Siemens / ABB / C & S / Schneider / GE\nVolt Meter/Ammeter : Havells / HPL / L & T / AE / Schneider / BCH
52 25 M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 32 x 6mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate), "mild steel angle iron frame" made out of MS angle iron of size 40x 40 x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering 40mm dia light grade, GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No '3' and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing as directed. 12 EACH SET