Repair And Maintenance Of Lightening Arrestors And Connecting Earthing Pits And Other Misc Works ( Including Checking And Bringing Down High E-N And E-R Value ) In Zone B Under Ge ( Af ) Tech Area Agra, GE (AF) TECH AREA AGRA-Uttar Pradesh

Military Engineer Services-MES has published Repair And Maintenance Of Lightening Arrestors And Connecting Earthing Pits And Other Misc Works ( Including Checking And Bringing Down High E-N And E-R Value ) In Zone B Under Ge ( Af ) Tech Area Agra. Submission Date for this Tender is 04-02-2021. Electrification Work Tenders in GE (AF) TECH AREA AGRA Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

26592948
Corrigendum : Repair And Maintenance Of Lightening Arrestors And Connecting Earthing Pits And Other Misc Works ( Including Checking And Bringing Down High E-N And E-R Value ) In Zone B Under Ge ( Af ) Tech Area Agra
National Competitive Bid
Indian
Uttar Pradesh
GE (AF) TECH AREA AGRA
04-02-2021

Tender Details

Repair And Maintenance Of Lightening Arrestors And Connecting Earthing Pits And Other Misc Works ( Including Checking And Bringing Down High E-N And E-R Value ) In Zone B Under Ge ( Af ) Tech Area Agra

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Jan-2021 Corrigendum BOQ 28-01-2021
2 28-Jan-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-02-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 91000.0 /-
Tender Value
INR 45.50 Lakhs /-

BOQ Items

Name of Work: REPAIR AND MAINTENANCE OF LIGHTENING ARRESTORS AND CONNECTING EARTHING PITS AND OTHER MISC WORKS ( INCLUDING CHECKING AND BRINGING DOWN HIGH E-N AND E-R VALUE ) IN ZONE 'B' UNDER GE (AF) TECH AREA AGRA.
Sl. No. Item Description Item Code / Drawing No. Quantity Units
1 1 S&F in repair Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed. 300 EACH
2 2 S&F in repair Air termination, single pointed copper rod 12mm dia and 300mm long complete all as specified and directed. 250 EACH
3 3 S&F test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled screwed including 3 Nos, 8mm dia, 25mm long hex head screw complete all as specified and directed. 400 EACH
4 4 S&F in repair copper strip 20 x 3.15 mm with saddles/insulators and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. 250 RM
5 5 S&F in repair copper strip 32 x 6 mm with saddles/insulators and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. 200 RM
6 6 S&F in repair galvanised strip 25 x 4 mm with saddles/insulators and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. 300 RM
7 7 S&F in repair galvanised strip 30 x 5 mm with saddles/insulators and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. 250 RM
8 8 S&F aluminium strip 25 x 3 mm with porcelain insulator and fixing screws etc. on roof/wall and connecting to test point etc. complete all as specified and directed. 500 RM
9 9 M&L for earth continuity conductor or main earthing lead fixed on wall on batten or recess or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised wire including suitable size lugs complete all as specified and directed. 100 RM
10 10 M&L for earth continuity conductor or main earthing lead fixed on wall on batten or recess or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia copper wire including suitable size lugs complete all as specified and directed. 200 RM
11 11 M&L for brazing/welding of earthing electrode complete all as specified and directed. \nNote for item No. 1 to 11:- Working height of hangar & bldg is upto 18 mtr. The contractor will arrange all T&P and all type of safety arrangement .Cost of which shall deemed to be included in quoted rates and no extra payment shall be paid to contractor on this account. 200 EACH JOB
12 12 M&L for GI tubing light grade, 25 mm dia galvanised with and including all fittings for earthing lead protection under ground /on wall complete all as specified and directed. 100 RM
13 13 M&L GI tubing light grade, 40mm bore in vertical position of 1.0 mtr length for mounting of Air termination rod and embedded in PCC complete all as specified and directed. \nNote:The cost of PCC shall be measured and paid separately under appropriate item. 200 RM
14 14 M&L for GI tubing light grade, 50 mm dia galvanised with and including all fittings for earthing lead protection under ground /on wall complete all as specified and directed. 150 RM
15 15 M&L for 15 mm bore GI tubing medium grade in fixed to wall/ceiling with & including required GI fitting complete all as specified and directed. 250 RM
16 16 M&L for 20 mm bore GI tubing medium grade in fixed to wall/ceiling with & including required GI fitting complete all as specified and directed. 300 RM
17 17 S&F bib tap/stop cock 15mm bore standard of PTMT any colour screwed for iron pipe and fixed complete all as specified and directed. 150 EACH
18 18 Cutting chases, pinning in making good to facings where required and pointing in cemant mortar 1:3 to ends or edges of landings, steps, cills, sunsheds, shelves, lintels, etc; and cutting chases for concealed conduit wiring,etc, and making good, cutting not exc 10 cm girth complete all as specified an directed. 100 RM
19 19 M&L for painting of earthing pit cover with one coat primer and two coat of synthetic enamal paint and indicate with colour code Red & Yellow complete all as specified and directed. 1000 EACH JOB
20 20 M&L for PCC(1:3:6:) type C-1 using 20mm graded stone aggregate as in base support of struts and other similar location etc with and including all necessary form work complete all as specified and directed. 15 Cum
21 21 M&L for earthing complete with copper plate electrode 600mmx600mmx3.15 mm thick buried directly in ground (earth pit not less than 3.00 Mts deep below ground level with top edge of the plate not less than 2.25 Mtrs below ground level connected to copper strip 20 X 3 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified including necessary excavation and earth work and disposal of surplus soil to a distance n. exc 50m including 40 mm GI tubing light grade and necessary fitting for protection of copper strip including laying of charcoal dust and common salt, PCC (1:2:4) type B-1 using 20mm graded stone aggregate earth pit with 40x40x6mm MS angle iron frame, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6 mm dia round bar @ 75mm C/C both ways with MS handle 12mm dia round bar, plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally, PGI funnel with 20mm dia GI pipe for watering and wire mesh complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test including testing complete all as specified and directed. 40 EACH JOB
22 22 M&L for chemical earthing with copper earth plate electrode 900x600x5mm burried directly in earth pit not less than 4.7 mtr below normal ground level and complete size of pit 1.6 mtr x 0.61 m x 5.10m, earth plate connected to copper strip 32x6 mm by means of copper/brass nut, bolt duly brazed earth strip protected with 40 mm bore light grade GI pipe from electrode and upto and including the earth test point of gun metal/ phosphorous bronze of size 75x75x25 mm, 20 mm bore watering pipe, medium grade GI pipe including funnel , wiremess providing alternate layer of 10 cm each charcoal salt and magnesium suplhate layer upto 1.20mtr and 2kg copper sulpate to be added around the plate for better result and including excavation and earth work, removal of surplus soil to a distance not exceeding 50m , PCC pit in PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate RCC Cover 40 mm thick in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm dia MS deformed bars @ 100 mm c/c both ways including MS handle of 12 mm dia round bar etc to be placed on and including angle iron frame made of section 40x40x3 mm of angle iron including plastering 15mm thick in CM 1:6 internally & upto 150mm below ground level externally including treating complete all as specified an directed.\nNote for item No. 21 to 22:- (i) Cost of copper strip and protection light grade GI pipe upto 7.5 mtr shall deemed to be included in the quoted rates. \n(ii) The earthing value of each earthing pit to be below 1 ? (Ohm). 15 EACH JOB
23 23 M&L for earthing complete with galvanised steel plate electrode 600mmx600mmx6 mm thick buried directly in ground (earth pit not less than 4.00 Mts deep below ground level with top edge of the plate not less than 3.25 Mtrs below ground level connected to galvanised iron strip 25 x 4 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified including excavation and earth work and disposal of surplus soil to a distance n. exc 50m including 40 mm GI tubing light grade and necessary fitting for protection of galvanised strip incl laying of charcoal dust and common salt PCC (1:2:4) type B-1 using 20mm graded stone aggregate earth pit with 40x40x6mm MS angle iron frame, RCC cover 40mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 6 mm dia round bar @ 75mm C/C both ways with MS handle 12mm dia,round bar, plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally, PGI funnel with 20mm dia GI pipe for watering and wire mesh complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test including testing complete all as specified an directed. \nNote :- Cost of GI strip and protection light grade GI pipe upto 7.5 mtr shall deemed to be included in quoted rate. 80 EACH JOB
24 24 Supply and installation of advanced encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgraded (Zinc & Alloy coated), (80-100) microns Zinc Coating with pure Zinc (99.90%) & (200-250) Alloy Coating, dia of outer and inner pipe should be 76.2mm & 41.9mm respectively and 3.0M length of each, Zinc Coating with additional special alloy coating on the topside (300mm) for additional protection of the terminal, annuar space between the pipes should be COMPACTED FILL (CF) with & including Crystalline Conductive Compound by using machine, machine pressed COMPACTED FILL (CF) mixture in the pipes should not disintegrate or colloapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity, digging the pits and refilling the same with & including Electrodite/ Conductolite back fill compound (Ground Enhancer) and back fill compound (BFC) should be eco friendly & should not contain environmentally hazardous material/ metal and also having RoHS certification from NABL accredited lab. The earth pit should be provided with a RCC earth pit cover 1:3:6-20MM agregates and including FI clamps 40x6mm -2nos.(4mm long each clamp)for protection and safe guard of terminals. In areas, where soil condition is bad, good earth is to be arranged to fill the excavated pits by mixing the same with back fill compound (BFC) 2 to 4 bags (as per soil conditions) extra per pit/ unit. Since earth electrode of the earthing system should be in direct contact with the ground, hence, materials which to be used in the earthing, should have good electrical conductivity & anti corrosion property in wide range of soil conditions and complete earthing system conforming to IS : 3034 complete all as specified and directed.\nMake:- INDELAG or ASHLOK or MACMET as approved by GE. \nNotes:(i) Cost of excavation and all earth work shall deemed to be included in the unit rate as quoted by the contractor. \n(ii) The earthing value of each earthing pit to be below 1 ? (Ohm) on testing after completion.If the desired earth resistance is not obtained the earthing will be redone at no extra cost. 10 EACH JOB
25 25 Disconnecting of GI earthing strips/earth wire leads of any size, any description and in any position from test point carefully and testing the earth resistance of any type of lightening conductor earthing with the help of earth tester of suitable capacity and recording Ohm value in the register as per proforma approved by Engineer-in-Charge including cleaning vegetation/wild growth sorrounding of 2 Mtr the earth pit and removing dust/deposited soil from earth pit complete all as specified an directed.\n 2550 EACH JOB
26 25.01 Note : (i) The contractor will arrange Earth Tester and all T&P & accessories for recording the reading.\n(ii) The contractor shall arrange for watering of the earth pit through watering pipe in the earthing to improve the resistance. Common salt min. 5 Kgs for each earthing pit shall be mixed with the water at site and filled/dropped in earthing through watering pipe as per site condition and as directed by Engineer-in-Charge. The water for this purpose shall be made available by the Deptt. at the nearest available source but contractor shall make his own arrangement for drawing water from this source.Cost for which shall deemed to be included in quoted rate and no extra payment shall be paid to contractor. \n(iii) The record of resistance value of each earthing alongwith date of testing shall be maintained on register as per format approved by Engineer-in-Charge. \n(iv) (a) 01 x Electrician and 01 x helper will be detailed by the contractor for attending above complaints daily basis. Cost for which shall be deemed to be included in quoted rates.\n(b) Replacement of major items shall be measured and paid under relevant items of this schedule.\n(c) Electrician and helper so detailed by the contractor will report to MES complaint cell at 0800 hrs morning all working day to receive complaint slip from department and complaints shall be rectified within 08 hours. If contractor fails to detail above tradesmen, a panel recovery @ Rs 500.00 per day shall be made to the contractor and the shall be recovered from RAR/final bill. \n(v) Testing of the earthing shall be carried out periodically as directed by Engineer-in-Charge as per site requirement and unit rate quoted by the contractor for all the material and arrangements shall deemed to be included for all the provisions for testing of the earthing for one time.
27 26 M&L for precast cement concrete (1:2:4) type B1 using 20mm graded stone aggregate of size approx 450x450x50mm thick as in earth pit cover with 3 nos 8 mm dia TMT bars both ways with 8 mm dia round bar handle including provision of lifting arrengement made out fo 8mm dia round bar complete all as spacified and directed. 200 EACH JOB
28 27 M&L for MS work/ steel nut ,bolt & washer of suitable size/all arrangements and complete all as specified and directed. 50 KG
29 28 M & L for MS sheet 30 x 20cm, thickness of 2mm shape of square/round/triangle as per sample including bar 10mm dia, 90 cm long framed work with shape of 'T' etc, necesary welding, earth works, etc painting / marking of TESTED ON -------, RESULT --------------, and all arrangements including PCC (1:3:6) Type C1 using 20 mm graded stone aggregates of size 150x150x150mm complete all as specifed and directed . 250 EACH JOB
30 29 M&L for renewal of earthing by using of chemical copper sulphate including T&P equipment with all safty measures complete all as spacified and directed. 300 KG
31 30 M&L for renewal of earthing by using of chemical Zinc sulphate including T&P equipment with all safty measures complete all as spacified and directed. 500 KG
32 31 Excavation in trenches in soft/ loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line,and getting out complete all as specified and directed. 270 CUM
33 32 Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in soil complete all as specified and directed. 182.5 CUM
34 33 Removing excavated soil n. exc 50 m and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and directed. 87.5 CUM
35 34 M&L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover, laid flat and dry in trenches over the cable prependicular to the direction of cable complete all as specified and directed. 8 PER 1000 NOS
36 35 M&L for local sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable complete all as specified and directed.\nNote : Thickness of sand will be measured after punning for payment purpose. 60 CUM
37 36 Taking out old serviceable/ unserviceable LT UG cables of any size of 10 to 25 sq mm, 2/3.5/4 core from trenches, poles/walls and floor includuing taking out old serviceablee bricks from trenches complete all as specified and directed. 1200 RM
38 37 Supply and laying XLPE, LT UG cable PVC insulated , armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 16 sq mm, 4 core in trenches or fixed on wall/floor/poles complete all as specified and directed. 350 RM
39 38 Supply and laying XLPE LT UG cable PVC insulated , armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 25sq mm, 4 core in trenches or fixed on wall/floor/poles complete all as specified and directed. 300 RM
40 39 Supply and laying XLPE LT UG cable PVC insulated , armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 35 sq mm, 3.5 core in trenches or fixed on wall/floor/poles complete all as specified and directed. 275 RM
41 40 Supply and laying XLPE LT UG cable PVC insulated , armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 50 sq mm, 3.5 core in trenches or fixed on wall/floor/poles complete all as specified and directed. 225 RM
42 41 Supply and laying XLPE LT UG cable PVC insulated , armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 95 sq mm, 3.5 core in trenches or fixed on wall/floor/poles complete all as specified and directed. 50 RM
43 42 M& L for checking and balancing of electric load on each DB and by disconnecting and check E-N and E-R in permissibe limit and proper recconnecting including disconnection of circuit and reconnection after balancing of load complete all as specifie and directed. 150 EACH JOB
44 43 S&F Sheet metal enclosure TPN DB double door 12 ways complete all as specifie and directed. 25 EACH
45 44 S&F Sheet metal enclosure TPN DB double door 6 ways complete all as specifie and directed. 20 EACH
46 45 M&L for sub main wiring drawing in and including PVC surface conduit not less than 20mm dia medium grade with PVC insulated unsheathed copper conductor single core cable 4x10.00 Sqmm and 2x6 sqmm as earth wire with all accessories complete all as specifie and directed. 100 RM
47 46 M&L for sub main wiring drawing in and including PVC surface conduit not less than 20mm dia medium grade with PVC insulated unsheathed copper conductor single core cable 2x6.00 Sqmm and 1x4 sqmm as earth wire with all accessories complete all as specifie and directed. 150 RM
48 47 M&L for sub main wiring drawing in and including PVC surface conduit not less than 20mm dia medium grade with PVC insulated unsheathed copper conductor single core cable 2x4.0 Sqmm and 1x2.5 sqmm as earth wire with all accessories complete all as specifie and directed. 200 RM