Special Repair/Rewiring Including Upgradation Of Circuit In Adm Block Of 322 Inf Bde And Provn Of 50 X Desert Coolers In Bldg No . P-285 Of 8 Jak Rif At Jaipur Mil Stn Under Ge ( South ) Jaipur, JAIPUR-Rajasthan

Military Engineer Services-MES has published Special Repair/Rewiring Including Upgradation Of Circuit In Adm Block Of 322 Inf Bde And Provn Of 50 X Desert Coolers In Bldg No . P-285 Of 8 Jak Rif At Jaipur Mil Stn Under Ge ( South ) Jaipur. Submission Date for this Tender is 09-02-2021. Electrification Work Tenders in JAIPUR Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

26590730
Corrigendum : Special Repair/Rewiring Including Upgradation Of Circuit In Adm Block Of 322 Inf Bde And Provn Of 50 X Desert Coolers In Bldg No . P-285 Of 8 Jak Rif At Jaipur Mil Stn Under Ge ( South ) Jaipur
National Competitive Bid
Indian
Rajasthan
JAIPUR
09-02-2021

Tender Details

Special Repair/Rewiring Including Upgradation Of Circuit In Adm Block Of 322 Inf Bde And Provn Of 50 X Desert Coolers In Bldg No . P-285 Of 8 Jak Rif At Jaipur Mil Stn Under Ge ( South ) Jaipur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Feb-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-02-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 37700.0 /-
Tender Value
INR 18.85 Lakhs /-

BOQ Items

Name of Work: Special repair/rewiring including upgradation of circuit in Adm block of 322 Inf Bde and Provn of 50 x desert coolers in bldg No. P-285 of 8 JAK Rif at Jaipur Mil Stn under GE(South) Jaipur
Sl. No. Item Description Item Code / Make Quantity Units
1 1 19/SR Bldg/61SA/2020-21\nTaking down carefully copper/ aluminum point wiring (light, fan, socket or power) complete including all fittings such as switches, ceiling roses, pendants, sockets, lamp holder, brackets light fittings tube light fitting, bell/ buzzer ,regulator etc (excluding fans) and making good disturbed surfaces of wall floors, ceiling etc complete all as specified and as directed by Engr-in-Charge to match with existing surface. 529 Point
2 2 M&L Point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 Sq. mm (nominal area), single core, FRLS insulated, PVC insulated and unsheathed stranded cable 1100 volts grade, ISI marked ( IS-694) in and including concealed conduit , medium grade, ISI marked, with mild steel sunken boxes with earth dolly zink coated and including mounting frame and over cover plate, including PVC insulated stranded copper conductor 1.5 Sqmm (nominal area) single core cable as earth continuity conductor to common earth and connected FRLS cable 1100 V grade as continuous earth wire to earth dolly for followings:-
3 2.01 One light / fan / bell controlled by one, one way switch. 225 Point
4 2.02 One 3 pin 5 Amp socket out let on the same board with other switches 79 Point
5 2.03 One 5 Amp socket independent controlled by one, one way switch. 90 Point
6 3 All as per item No 2 above but 2.5 Sqmm copper cable for 3 pin switch socket outlet15Amp independent board, including 2.5 sqmm copper cable continuous earth wire and connecting to common earth dolly complete all as specified and directed by Engineer in charge . 105 Per\nPoint
7 4 All as per Item No 2 above but with 4 Sqmm copper cable for 3 pin 15 Amps socket outlet on independent board, including 4.0 Sqmm copper cable continuous earth wire and connecting to common earth dolly for AC complete all as specified and directed by Engineer-in-charge. 30 Point
8 5 Supply&.Fixing Switch ,moduler type type 230/ 250V grade on top covers (catered in point wiring above) :-
9 5.01 Single pole, one way 6 Amp rating. 390 Each
10 5.02 Single pole, one way 16 Amp rating. 105 Each
11 5.03 Bell push flush type, 6 Amp 4 Each
12 6 S&Fixing Socket outlet multipurpose use, Modular type non/shuttering non/ interlocking flush mounting type, 230/250 Volts grade on top covers (catered in point wiring above) :-
13 6.01 5 Pin 6 Amp (with 2 pin out let of 5 Amp also). 169 Each
14 6.02 6 Pin 16 Amp (with 3 pin out let of 5 Amp also). 105 Each
15 7 S&F Electric bell multi music type AC 230 volts single pole for AC 230V, 50 Hz .ding dong type(ISI marked) 4 Each
16 8 S&F Lamp holder insulated body with back plate for batten fitting. Make Anchor/bajaj/philips 36 Each
17 9 M&L Ceiling rose surface bakelite 65x50mm, three terminals ,(ISI marked). 166 Each
18 10 Supply&Fixing speed regulator modular type for ceiling fan electronic type 230 Volts complete.\nMake Anchor Cat Pt No- 22546 or equivelent model in Havells/Bajaj / CG 35 Each
19 11 Supply & Fixing LED tube light T-5 tubular lamp IP 20 LED T5 18 watt with complete with inbuilt driver complete all as specified and directed \nMake - Syska cat pt No- SSK-MU-1801 or equivelent model in Bajaj/Havells/ Philips 136 Each
20 12 Supply & fixing Mirror surface mounted LED fitting 14 W (2 Feet)provided with a high output PMMA diffuser for glare free light , IP 20 with high brightness LEDs complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size. Make - Crompton cat pt No- LCL-14-CDL or equivelent model in Bajaj/Havells/ Philips/Wipro/Siska /Shakti fixture 10 Each
21 13 Supply & fixing , LED Light fittings 2'x2' square PL 6.5K (surface) 36 w(Aluminum body), long life, corrosion resistant , surface/wall mounting IP 20 luminaire with PC housing in opal finish suitable for wet location with high brightness LEDs complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size.Make - SYSKA cat Pt No- SSK-PAB-6060B-2 36- Watt 20 Each
22 14 Supply and Fixing security lights LED 30 W Energy saving & Environmental friendly long life versatile pressure die cast aluminium IP 66 LED Wall mounted Light Luminaries are made of die casted aluminium body and toughened glass cover for uniformlight spread cames LED technology of Britelite. The Lights are equipped with state of the art scrche and lock design, dimensional heat management LED system of Size 45 watt including bracket made out of suitable size of GI medium grade tubing 2 metre long and bent to shape at 120 degree angle at the middle from vertical, fixed with clamps nuts and bolts, washer complete all as specified .\nMake- CG cat Pt No-LSTS-30-CDL or equivalant in HAVELLS ,Syska ,Phillips,Shakti fixture,C &S\n 6 Each
23 15 M&L for Sub main wiring with two runs of 6 Sqmm single core FRLS PVC insulated but in unsheathed multi stranded copper conductor cable 1100 volts grade drawn through and including of 25mm dia PVC rigid conduit medium with conduit accessories and fixed to the surface of wall/ceiling as per ISI including 6.0 Sqmm PVC insulated copper conductor earth continuity wire. \n19/SR Bldg/20-21 - 75\n22/LBW/20-21 - 68\n 143 RM
24 16 M&L for Sub main wiring with four uns of 10 Sqmm single core FRLS PVC insulated but in unsheathed multi stranded copper conductor cable 1100 volts grade drawn through and including of 25mm dia PVC rigid conduit medium with conduit accessories and fixed to the surface of wall/ceiling as per ISI including 10.0 Sqmm PVC insulated copper conductor earth continuity wire. \n 180 RM
25 17 Taking down sub main wiring of aluminum/copper with PVC/ steel conduit. 255 RM
26 18 S&F in repair factory made, sheet distribution boards, double door protection class IP-42 double door type suitable for mounting MCB/ MCCB, confirming to IS-13032, IS-8623, BS-5484 with minimum 200 amps, copper bus bar of the under mentioned rating :-
27 18.01 SP&N 8 ways 8 Each
28 18.02 SP&N12 ways 6 Each
29 18.03 TPN 4 Ways 6 Each
30 19 S&Fin repair MCB 10 KA confirming to IS-8828 : 1996, IEC-898 : 1995 rupturing capacity of the under mentioned type and rating :-
31 19.01 SP 5 to 32 Amps 130 Each
32 19.02 TPN 63 Amp 6 Each
33 19.03 SPN 32 to 63 amps. 14 Each
34 20 RCBOs for earth leackage , overload & short circuit protection 4 pole 300 MA leackage currunt and 63 Amp capacity complete all as specified and directed. 4 Each
35 21 RCBOs for earth leackage , overload & short circuit protection 2 pole 100 MA leackage currunt and 32 Amp capacity complete all as specified and directed. 4 Each
36 22 Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm burried directly in ground (earth pit not less than 2.25 meters deep below normal ground level ), with top edge of the plate not less than 1.5 mtrs below normal ground level , connected to and including galvanised earth wire 4 mm by means of galvanised iron bolts , nut and washers and connected to other end to main panel board duly protected by galvanised iron pipe 15 mm dia " light grage " earth plate surrounded by packed layer of coal dust and common salt 15 cm thick all around bottom and top, watering pipe 20 mm bore of galvanised iron " medium grade " with funnel all as shown on electrical plate No 3 of SSR part -I and connecting to earthing testing on completion including cast iron cover frane and PCC 1:3:6 type C-1 using 20 mm grade stone aggregate as in earthing pit with cast iron cover and frame including necessary excavation and earth work and teting etc complete all as per specified and directed by Engr-in-Charge .\n 3 Each Set
37 23 Supply and fix in repair sheet metal enclosure complete with metallic plug and socket heavy duty moduler type 3 pin (2P + Earth), 32 amp rating single phase 240 volts complete with MCB SP 32 amp “C” series 30 Each
38 24 M & L for exhaust fan 300 mm sweep compete all as specifed and directed 2 Each
39 25 Supply and fix Louver made of galavnised iron 300 mm dia including fixing with suitable fastner complete all as specifed and directed 2 Each
40 26 Supply, install, test and commissioning of indoor type LT Panel Board cubical type made out of 2 mm thick CRCA sheet confirming to IS - 8623 indoor type totally enclosed single door hinged type front opening (glasses for showing meter reading), weather dust and vermin proof top, powder coated painting, locking arrangement, entry holes and glands of suitable size for incoming / outgoing cables including necessary arrangements for grounting on wall with proper fastner and internal copper control wiring of suitable size for instrument, suitable size of copper strip for power connections from copper Bus-bar, suitable arrangement for three pahse meters 01 Nos , RYB Indicating Lamps - 1 Set, complete all as specfied and directed including taking down old with the following :- .\n(a) MCCB 4 Pole, 200 Amps 415 Volts 25 KA - 01 NO (incoming supply)\n(b) MCCB 4 Pole, 100 Amps 415 Volts 25 KA - 01 NO (incoming supply)\n(c) MCB TPN 63 Amps 415 Volts 10 KA - 01 NO \n(d) SPN 32 Amps 415 Volts 10 KA Model - C-Curve - 02 NO\n(e) MCB SP 5-32 Amps 415 Volts 10 KA Model - C-Curve - 12 NO \n(f) On Load Change Over Switch 125 Amp, 4 Pole confirming to IS/IEC 60947-3/IS 13947-3, modular construction - 01 Nos\n(e) Space for Digital tamper proof elect meter-01 Nos. 1 Each
41 27 22/LBW/61SA/20-21 (Desert Cooler)\nFabrication of cooler stand made of 40mm x 40mm x 5mm MS angle iron including provn of cutting holes in stone masonary wall built in cement mortar for inserting angle iron and grouting angle iron in wall not less than 15cm in cement mortar (1 :3) or PCC ( 1:2:4) inside and angle iron shall br painted with two coats of synthetic enamalled paint over a coat of red oxide primer as directed by Engr-in- charge.\n Note : The disturbed surface of wall shall be made good in cement mortar (1:3) \n 6 Qtl
42 28 Supply and installed Desert Cooler electric driven (single phase)having copper winding exhaust fan type of 450 mm sweep fan motor with 3 leaf aluminum blade 1400 RPM and power consumption of 350 Watts(Make-crompton greaves or equivalent make), nominal airflow capacity of 6000cum per hour including PVC submersible pump copper winding complete single phase 230 volts , ISI marked Galvanized non corrosive steel body(minimum 20 gauge) and body dimension (1150mm X750mmX750mm) ,front grill rectangular shape and three side with opening steel shutter with wooden chips pad and water storage tank capacity 90 ltr and three step rotary type controller including PVC pipe fitting , including PVC float valve 15 mm size with ON/OFF switch and all as specified and directed by Engr-in -charge. 50 Each
43 29 M&L Point wiring complete with PVC insulated and unsheathed cable 2.5 sq mm (nominal area) ISI marked ,FRLS,multi-stranded copper conductor single core including ISI marked PVC casing and capping with fittings and accessories fixed to wall / ceiling by means of PVC rowl plugs fastener with screws including hard wood board with top cover 3mm thick of plastic laminated sheets of required colour , and including 1.5 Sqmm PVC insulated and unsheathed FRLS,stranded copper wire conductor cable to common earth and connecting to earth dolly including colour coding of cable shall be Phase - Red, Neutral- Black and Earth- Green complete. 50 Point
44 30 Supply&.Fixing Switch piano type 230/ 250V grade on top covers (catered in point wiring above) Single pole, one way 15 Amp rating. 50 Each
45 31 S&Fixing Socket outlet multipurpose use flush mounting type, 230/250 Volts grade on top covers (catered in point wiring above) 6 Pin 15 Amp (with 3 pin out let of 5 Amp also). 50 Each
46 32 M&L for gun metal gate valve with iron wheel head, screwed both ends for jointing iron pipes, non rising, forged brass spindle class-1, ISI marked of following sizes. Make :-Zoloto/Venus/Leader
47 32.01 15mm dia 50 Each
48 32.02 20mm dia 4 Each
49 32.03 25mm dia 2 Each
50 33 Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth and getting out in soft and loose soil including trimming of sides and bottom of trenches complete all as specified. 15 Cum
51 34 Returning, filling-in, including spreading, watering and well ramming in layers n.exc 25cm thick each in soft/loose soil completes all as specified. 11.8 Cum
52 35 Removing excavated surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified. 3.2 Cum
53 36 M&L for tubes " medium grade " galvanised steel (GI) ISI marked with all fittings and fixed complete to walls and celling or laid in floors / trenches of the folowing sizes : Make:Surya parkash ,TATA
54 36.01 15 mm bore of pipe 350 RM
55 36.02 20mm bore of pipe 75 RM
56 36.03 25mm bore of pipe 35 RM
57 37 S&F Factory made, sheet distribution boards, double door protection class IP-42 suitable for mounting MCB/ MCCB, confirming to IS-13032, IS-8623, BS-5484 r of the under mention rating
58 37.01 SP&N 8 ways 2 Each
59 38 S&F MCB 10 KA confirming to IS-8828 : 1996, IEC-898 : 1995 rupturing capacity of the under mentioned type and rating :-
60 38.01 SP 5 to 32 amps 12 Each
61 38.02 SPN 32 to 63 amps. 2 Each
62 39 PVC connections 15mm size with PTMT nuts of length 900mm for connection of desert cooler with GI pipe compete all as specified and directed 50 Each