Road Transport and Highways Government Departments Closing in 0 days TDR #26586361

Rehabilitation And Up Gradation Of Thrissur - Kuttippuram Road ( Length Of 33 . 243 Km ) In Thrissur District

Issued by Government Departments · Thrissur, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
09 Mar 2021
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thrissur → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Rehabilitation And Up Gradation Of Thrissur - Kuttippuram Road ( Length Of 33 . 243 Km ) In Thrissur District

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 03-Feb-2021 Addendum1 Other 26-Feb-2021
2 23-Feb-2021 Corrigendum 1 Date 09-Mar-2021

BOQ

Name of Work: Rehabilitation and Up gradation of Thrissur - Kuttippuram Road (Length of 33.243 Km) in Thrissur District
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Bill No. 1 SITE CLEARANCE AND DISMANTLINGBI01010001010000000000000515BI0100001112
21.01Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned including removal and disposal of top organic soil not exceeding 150 mm thickness with all lead & Lift , all complete as per Technical Specification Clause 201.BI01010001010000000000000515BI01000011135.48Ha
31.02Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead - By Mechanical Means as per MoRTH Specifications Clause 202BI01010001010000000000000515BI0100001114
41.021Plain Cement ConcreteBI01010001010000000000000515BI010000111576.76Cum
51.022Reinforced Cement ConcreteBI01010001010000000000000515BI010000111610163.8Cum
61.023Dismantling RCC work of CulvertsBI01010001010000000000000515BI01000011171303.92Cum
71.024Dismantling RCC work of BridgesBI01010001010000000000000515BI0100001118290.46Cum
81.03Dismantling of flexible pavements / Non bituminous base/sub-base courses and disposal of dismantled materials with all lead and lift, stacking serviceable and unserviceable materials separately Bituminous course - By Mechanical Means as per MoRTH Specifications Clause 202BI01010001010000000000000515BI0100001119
91.031Pavement Bituminous coursesBI01010001010000000000000515BI010000112017765.7Cum
101.032Non bituminous base/sub-base coursesBI01010001010000000000000515BI010000112112890.1Cum
111.04Removal of stumps and roots of girth above 300mm and back filling to required compactionwith all lead & lift ,all complete as per Technical Specification Clause 201 and 305.BI01010001010000000000000515BI0100001122
121.041Girth from 900 mm to 1800 mmBI01010001010000000000000515BI0100001123112Nos.
131.042Girth above 1800 mmBI01010001010000000000000515BI010000112465Nos.
142Bill No. 2 EARTH WORKBI01010001010000000000000515BI0100001125
152.01Excavation for roadwork in all type of soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead all complete as per Technical Specification Clause 301.BI01010001010000000000000515BI0100001126
162.011Excavation in all types of soilsBI01010001010000000000000515BI010000112774773.5Cum
172.02Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Table 300-2 and as per drawings and MoRTH Specifications Clause 305BI01010001010000000000000515BI010000112816106.3Cum
182.03Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table No. 300-2 and as per drawings and MoRTH Specifications Clause 305 & 408BI01010001010000000000000515BI010000112918811.7Cum
192.04Loosening of the ground upto a level of 500 mm below the sub-grade level, watered, graded and compacted in layers to meet requirement of Table 300-2 for Compacting original ground supporting sub-grade construction and as per MoRTH Specifications Clause 305BI01010001010000000000000515BI010000113013766.9Cum
202.05Construction of median and Island above road level with approved material brought from borrow pits, spread, sloped and compacted as per MoRTH Specification clause 408BI01010001010000000000000515BI01000011311607.12Cum
213Bill No. 3 GRANULAR SUB-BASE AND BASE COURSESBI01010001010000000000000515BI0100001132
223.01Construction of granular sub-base by providing close graded material conforming to grading-V of table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 of Technical Specifcations.BI01010001010000000000000515BI010000113354284.6Cum
233.02Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam Specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per MoRTH Specification Clause 406.BI01010001010000000000000515BI010000113424103.2Cum
244Bill No. 4 BITUMINOUS / PQC COURSESBI01010001010000000000000515BI0100001135
254.01Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means all complete as per Clause 502.2BI01010001010000000000000515BI010000113658494.6Sqm
264.02Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.30 kg/sqm on the prepared bituminous/granular surface cleaned with mechanical broom all complete as per Clause 503.BI01010001010000000000000515BI0100001137288436Sqm
274.03Providing and laying dense bituminous macadam with 80-100 TPH HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder (VG 30) @ 4.0 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH Specification Clause No. 505 complete in all respects. \nGrading - I (37.5 mm Nominal Size) Note : The Binder content specified shall be minimum 4.0 % but will conform to requirement as per JMF. No additional cost shall be paid to the actual Binder Content as required in JMF.BI01010001010000000000000515BI010000113836500.6Cum
284.04Providing and laying Bituminous Concrete Grade II with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with Bituminous Binder minimum 5.4 % VG-30 grade, of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects..Note The Binder content specified shall be minimum 5.4% but will conform to requirement as per JMF. No additional cost shall be paid to the actual Binder Content as required in JMFBI01010001010000000000000515BI010000113911522.4Cum
294.05Construction of Dry Lean Cement Concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per Table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per Drawing and MoRTH Specifications Clause 601.BI01010001010000000000000515BI010000114016002.2Cum
304.06Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per Drawing and MoRTH Specifications Clause 602.BI01010001010000000000000515BI010000114131398.3Cum
315Bill No. 5 CULVERTSBI01010001010000000000000515BI0100001142
325.01Earth work in excavation of foundation of structures including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material in all types of soil with all lifts and leads complete as per Drawings and Technical Specification Clause 304.BI01010001010000000000000515BI010000114312667.4Cum
335.02Back filling behind abutments, wing walls and return walls with selected granular material of approved quality complete as per Drawing and Technical Specifications Clause 305.BI01010001010000000000000515BI01000011442297.88Cum
345.03Providing and laying of Filter mediaBI01010001010000000000000515BI0100001145
355.031with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.BI01010001010000000000000515BI0100001146658.65Cum
365.032underneath Cement Concrete blocks of size 0.3x0.3x0.3 m cast in Cement Concrete block complete as per Drawing and MoRTH Specifications Clause 2504.BI01010001010000000000000515BI0100001147281.44Cum
375.033underneath pitching in slopes complete as per Drawing and MoRTH Specifications Clause 2504BI01010001010000000000000515BI0100001148723.75Cum
385.04Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100 \nPCC Grade M15BI01010001010000000000000515BI0100001149760.76Cum
395.05Providing & Laying Reinforced Cement Concrete of M35 Grade in Open Foundation including formwork but excluding reinforcement complete as per Drawing and Technical Specification Sections 1000, 1500, 1700 and 2100.BI01010001010000000000000515BI0100001150539.14Cum
405.06Providing & Laying Reinforced Cement Concrete of M35 Grade in Substructure including formwork but excluding reinforcement complete as per Drawing and Technical Specification Sections 1000,1500, 1700 and 2200.BI01010001010000000000000515BI0100001151379.63Cum
415.07Furnishing and Placing RCC/PSC Grade M35 in solid slab super-structure as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2300. \nBI01010001010000000000000515BI0100001152470.26Cum
425.08Supply, Fitting and Placing coated HYSD bar Reinforcement (Fe 500 D) complete as per Drawing and MoRTH Specifications Section 1000 and 1600.\nFoundationBI01010001010000000000000515BI0100001153174.08MT
435.09Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia PVC pipe, extending through the full width of the structure with slope of 1V : 20H towards draining face complete as per Drawing and MoRTH Specifications Clause 2706BI01010001010000000000000515BI01000011542304Nos.
445.1Provision of Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-40 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all complete as per drawing & Technical Specifications Clauses 809 & 811 and Sections 1000, 1500, 1600, 1700 and 2200.BI01010001010000000000000515BI0100001155714.22Rm
455.11Providing and fixing in position drainage spouts using 100mm dia GI pipe ,complete as per drawings and Technical Specifications Clause 2705.BI01010001010000000000000515BI0100001156140Nos.
465.12Providing and laying in position 65 mm thick wearing coat consisiting of 40 mm bituminous concrete over a 25mm thick layer of mastic asphalt over deck slab after applying prime coat complete as per drawings and technical specification sections 500 and 2700BI01010001010000000000000515BI0100001157
475.121New ConstructionBI01010001010000000000000515BI01000011581152.3Sqm
485.122Rehabilitation and repair of existing culvertsBI01010001010000000000000515BI0100001159336Sqm
495.13Plain/Reinforced Cement Concrete in head wall complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100\nPCC Grade M20BI01010001010000000000000515BI0100001160343.69Cum
505.14Providing and laying of asphaltic plug joint to provide for horizontal movement of 25 mm and vertical movement of 2 mm, depth of joint varying from 75 mm to 100 mm, width varying from 500 mm to 750 mm ( in traffic direction), covered with a closure plate of 200 mm x 6 mm of weldable structural steel conforming to IS: 2062, asphaltic plug to consist of polymer modified bitumen binder, carefully selected single size aggregate of 12.5 mm nominal size and a heat resistant foam caulking / backer rod, all as per approved drawingsBI01010001010000000000000515BI010000116119.2Rm
515.15Providing and fixing of lifting MS hook capacity of 150 kg as directed by the Engineer as per approved Drawings and MoRTH Specifications Section 1600BI01010001010000000000000515BI010000116272Nos.
525.16Providing and fixing of Iron Step U shaped 20mm dia MS bar with capacity of 150 kg as per approved Drawings and as directed by EngineerBI01010001010000000000000515BI010000116398Nos.
535.17Sand Filling in Foundation Trenches as per Drawing & MoRTH Specifications Clause 1210BI01010001010000000000000515BI01000011641205.47Cum
545.18PCC M15 Grade leveling course below approach slab complete as per Drawing and MoRTH Specifications Section 1500, 1600 and 2700.BI01010001010000000000000515BI010000116510.37Cum
555.19Reinforced Cement Concrete Grade M30 approach slab including reinforcement and formwork complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1600 and 2700.BI01010001010000000000000515BI010000116620.16Cum
565.2Cement Concrete Blocks (size 0.5 x 0.5 x 0.5m) \nProviding and laying of apron with Cement Concrete blocks of size 0.5x0.5x0.5 m cast in-situ and made with nominal mix of M-15 grade Cement Concrete with a minimum cement content of 250 kg/cum as per IRC:21, MoRTH Specifications Clause 2503 and Sections 1000 & 1700.BI01010001010000000000000515BI0100001167721.31Cum
575.21Flexible Apron:Providing and laying of boulder apron on river bed for protection against scour with stone boulders as per Technical Specification Clause 2503.2BI01010001010000000000000515BI01000011681839.99Cum
585.22Providing Plain Cement Concrete M 15 for Encasing and Curtain wall etc. including formwork but excluding reinforcement complete as per drawing, Technical Specification Sections 1000,1500, 1700 and 2100.BI01010001010000000000000515BI01000011691692.19Cum
595.23Providing and laying Pitching on slopes laid over prepared filter media including boulder Stone/Boulder apron laid dry in front of toe of embankment complete as per Drawing and MoRTH Specifications Clause 2504BI01010001010000000000000515BI0100001170607.84Cum
605.24Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100. \nRCC Grade M30 - Using Batching Plant, Transit Mixer and Concrete PumpBI01010001010000000000000515BI0100001171654.58Cum
615.25Plain/Reinforced Cement Concrete in sub-structure complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2200. \nRCC Grade M30 - Height upto 5m - using Batching Plant, Transit Mixer and Concrete PumpBI01010001010000000000000515BI0100001172798.48Cum
625.26Supply, Fitting and Placing coated HYSD bar Reinforcement (Fe 500 D) complete as per Drawing and MoRTH Specifications Section 1000 and 1600\nSub-StructureBI01010001010000000000000515BI010000117363.88MT
635.27Painting of culvert No. and span arrangement with synthetic enamel complete as per Drawing and MoRTH Specifications Clause 803BI01010001010000000000000515BI010000117435Nos.
645.28Cleaning and removal of vegetation growth from structures, channel and protective works as per directions of the Engineer.BI01010001010000000000000515BI010000117556Sqm
655.29Repair of Existing Bridges by Cement Mortar 1:3 Plastering all complete as per MoRTH Specifications Section 1300.BI01010001010000000000000515BI0100001176350Sqm
665.3Guniting concrete surface with cement mortar applied with compressor after cleaning surface and spraying with epoxy complete as per directions of the Engineer.BI01010001010000000000000515BI010000117784sqm
675.31Providing, laying & jointing RCC NP4 pipe including testing complete as per Drawing & MoRTH Specifications Section 1000 and 2900.\n1200mm diaBI01010001010000000000000515BI0100001178318.2Rm
686Bill No. 6 BRIDGESBI01010001010000000000000515BI0100001179
696.01Earth work in excavation of foundation of structures including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material in all types of soil with all lifts and leads complete as per Drawings and Technical Specification Clause 304.BI01010001010000000000000515BI01000011809528.1Cum
706.02Back filling behind abutments, wing walls and return walls with selected granular material of approved quality complete as per Drawing and Technical Specifications Clause 305.BI01010001010000000000000515BI01000011811047.34Cum
716.03Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.BI01010001010000000000000515BI0100001182
726.031underneath pitching in slopes complete as per Drawing and MoRTH Specifications Clause 2504BI01010001010000000000000515BI0100001183490.55Cum
736.032underneath Cement Concrete blocks of size 0.3x0.3 x0.3 m cast in cement concrete block complete as per drawing and Technical specifications clause 2504.BI01010001010000000000000515BI0100001184107.22Cum
746.04Providing & Laying Plain cement concrete of M15 Grade in leveling course below foundation complete as per drawing and Technical Specification Sections 1000, 1500 and 1700.BI01010001010000000000000515BI0100001185260.16Cum
756.05Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100.\nRCC Grade M35 - Using Batching Plant, Transit Mixer and Concrete PumpBI01010001010000000000000515BI01000011861273.28Cum
766.06Plain/Reinforced Cement Concrete in sub-structure complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100.\nRCC Grade M35 - Using Batching Plant, Transit Mixer and Concrete PumpBI01010001010000000000000515BI0100001187538.74Cum
776.07Furnishing and Placing RCC/PSC Grade M35 Using Batching Plant, Transit Mixer and Concrete Pump as per drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2300.\nFor solid slab super-structure - Height 5m to 10m.BI01010001010000000000000515BI01000011881151.15Cum
786.08Supply, Fitting and Placing coated HYSD bar Reinforcement (Fe 500 D) complete as per Drawing and MoRTH Specifications Section 1000 and 1600BI01010001010000000000000515BI0100001189
796.081a) For sub-structureBI01010001010000000000000515BI010000119068.28MT
806.082b) For super-structureBI01010001010000000000000515BI0100001191103.61MT
816.083c) For foundationsBI01010001010000000000000515BI0100001192133.25MT
826.09Providing and laying of asphaltic plug joint to provide for horizontal movement of 25 mm and vertical movement of 2 mm, depth of joint varying from 75 mm to 100 mm, width varying from 500 mm to 750 mm ( in traffic direction), covered with a closure plate of 200 mm x 6 mm of weldable structural steel conforming to IS: 2062, asphaltic plug to consist of polymer modified bitumen binder, carefully selected single size aggregate of 12.5 mm nominal size and a heat resistant foam caulking / backer rod, all as per approved Drawings and MoRTH Specifications Section 2600BI01010001010000000000000515BI0100001193106Rm
836.1Providing and fixing in position drainage spouts using 100mm dia GI pipe ,complete as per drawings and Technical Specifications Clause 2705.BI01010001010000000000000515BI010000119442Nos.
846.11Providing and laying in position 65 mm thick wearing coat consisiting of 40 mm bituminous concrete over a 25mm thick layer of mastic asphalt over deck slab after applying prime coat complete as per drawings and technical specification sections 500 and 2700BI01010001010000000000000515BI0100001195
856.111New ConstructionBI01010001010000000000000515BI01000011961216.3Sqm
866.112Rehabilitation and repair of existing bridgesBI01010001010000000000000515BI01000011972730Sqm
876.12Providing and fixing Tar paper bearing complete as per drawing and Technical Specifications Clause 2011.BI01010001010000000000000515BI010000119831.8Sqm
886.13Furnishing and Placing Reinforced Cement Concrete Grade M25 Using Concrete Mixer in super-structure as per Drawing and MoRTH Specifications Section 410, 1000, 1500, 1600 & 1700, \nRaised -footpathBI01010001010000000000000515BI010000119975.06Cum
896.14Sand Filling in Foundation Trenches as per Drawing & MoRTH Specifications Clause 1210BI01010001010000000000000515BI01000012001419.57Cum
906.15Provision of Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-40 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all complete as per drawing & Technical Specifications Clauses 809 & 811 and Sections 1000, 1500, 1600, 1700 and 2200.BI01010001010000000000000515BI0100001201449.2Rm
916.16PCC M15 Grade leveling course below approach slab complete as per Drawing and MoRTH Specifications Section 1500, 1600 and 2700.BI01010001010000000000000515BI010000120257.24Cum
926.17Reinforced Cement Concrete Grade M30 approach slab including reinforcement and formwork complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1600 and 2700.BI01010001010000000000000515BI0100001203111.3Cum
936.18Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia PVC pipe, extending through the full width of the structure with slope of 1V : 20H towards draining face complete as per Drawing and MoRTH Specifications Clause 2706BI01010001010000000000000515BI0100001204817Nos.
946.19Furnishing and Placing Reinforced Cement Concrete Grade M25 Using Concrete Mixer in super-structure as per Drawing and MoRTH Specifications Section 400, 1000, 1500, 1600 & 1700, \nKerbBI01010001010000000000000515BI0100001205166.8Rm
956.2Cement Concrete Blocks (size 0.5 x 0.5 x 0.5m) \nProviding and laying of apron with Cement Concrete blocks of size 0.5x0.5x0.5 m cast in-situ and made with nominal mix of M-15 grade Cement Concrete with a minimum cement content of 250 kg/cum as per IRC:21, MoRTH Specifications Clause 2503 and Section 1000 & 1700.BI01010001010000000000000515BI0100001206729.65Cum
966.21Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall MoRTH Specifications Clause 2507.BI01010001010000000000000515BI0100001207859.82Cum
976.22Curtain/Toe wall complete as per drawing and Technical Specification section 1000,1500,1700 and clause 2507- Cement concrete Grade M20BI01010001010000000000000515BI0100001208216.36Cum
986.23Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and MoRTH Specifications Clause 2504.BI01010001010000000000000515BI0100001209214.43Cum
996.24Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100. \nRCC Grade M30 - Using Batching Plant, Transit Mixer and Concrete PumpBI01010001010000000000000515BI0100001210233.12Cum
1006.25Plain/Reinforced Cement Concrete in sub-structure complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2200. \nRCC Grade M30 - Height upto 5m - using Batching Plant, Transit Mixer and Concrete PumpBI01010001010000000000000515BI0100001211247.37Cum
1016.26Cleaning and removal of vegetation growth from structures, channel and protective works as per directions of the Engineer.BI01010001010000000000000515BI01000012121525Sqm
1026.27Repair of Existing Bridges by Cement Mortar 1:3 Plastering all complete as per MoRTH Specifications Section 1300.BI01010001010000000000000515BI01000012131000Sqm
1036.28Providing & laying stone pitching on slopes for erosion protection and open drain and drain joining rain water harvesting pit complete as per Drawing and MoRTH Specifications Section 2500 and as directed by the Engineer.BI01010001010000000000000515BI0100001214250Sqm
1047Bill No. 7 DRAINAGE AND PROTECTIVE WORKSBI01010001010000000000000515BI0100001215
1057.01Earthwork in excavation in all types of soil and rock with all lifts and leads complete as per Drawings and Technical Specification Clause 304.BI01010001010000000000000515BI0100001216
1067.011a) In all types of soilBI01010001010000000000000515BI010000121724786.7Cum
1077.02Construction of open/covered drain complete as per drawingBI01010001010000000000000515BI0100001218
1087.021a) Plain/Reinforced Cement Concrete in drain Foundation complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100. \nPCC Grade M15\nBI01010001010000000000000515BI01000012193082.19Cum
1097.022b) Providing and laying PCC/RCC M-20 grade for lined drains. including the cost of formwork but excluding the cost of reinforcement complete as per Drawing and MoRTH Specifications Section 1000, 1500 and 1700.BI01010001010000000000000515BI010000122011006Cum
1107.023c) Providing & fixing in position coated HYSD / TMT Fe 500 D grade bar reinforcement in base, walls and slab of RCC drains complete as per Drawing and MoRTH Specifications Section 1600.BI01010001010000000000000515BI0100001221550.31MT
1117.024d) Providing and laying RCC pipe 100 mm dia. complete as per Drawing and directed by EngineerBI01010001010000000000000515BI0100001222384.3Rm
1127.03Footpath: Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. as per Drawing and MoRTH Specification Section 400.BI01010001010000000000000515BI0100001223103462Sqm
1137.04Footpath :Construction of granular sub-base by providing graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MoRTH Specifications Clause 401.\nGrading-V - For sub base cum drainage layer - Mix in Place MethodBI01010001010000000000000515BI010000122415519.3Cum
1148Bill No. 8 BUS SHELTERBI01010001010000000000000515BI0100001225
1158.01Foundation for Wall and ColumnBI01010001010000000000000515BI0100001226
1168.011a) Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100. \nPCC Grade M15\nBI01010001010000000000000515BI010000122727.73Cum
1178.012Brick Masonry Work in Cement Mortar 1:4 in Foundation complete excluding Pointing and Plastering, as per Drawing and MoRTH Specifications Section 1300 for 1 stepBI01010001010000000000000515BI010000122820.34Cum
1188.013Brick Masonry Work in Cement Mortar 1:4 in Foundation complete excluding Pointing and Plastering, as per Drawing and MoRTH Specifications Section 1300 for 2nd stepBI01010001010000000000000515BI010000122912.96Cum
1198.02Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and MoRTH Specifications Section 1300BI01010001010000000000000515BI010000123095.94Cum
1208.03C:C floor for Platform / Precast Interlocking Paver BlocksBI01010001010000000000000515BI0100001231
1218.031Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100. \nPCC Grade M15BI01010001010000000000000515BI010000123239.51Cum
1228.032Providing and laying Anti-skid Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS: 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.BI01010001010000000000000515BI0100001233263.34Sqm
1238.04Sitting arrangement for PassengerBI01010001010000000000000515BI0100001234
1248.041Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and MoRTH Specifications Section 1300BI01010001010000000000000515BI01000012359.35Cum
1258.042Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge.With granite stone of area less than 0.50 sqm.BI01010001010000000000000515BI010000123622.8Sqm
1268.05Plastering with cement mortar (1:3 ) on brick work in sub-structure as per MoRTH Specifications Section 1300BI01010001010000000000000515BI0100001237906.61Sqm
1278.06Providing 10 mm thick plaster of Paris above brick wall as per Drawing and directed by EngineerBI01010001010000000000000515BI0100001238906.61Sqm
1288.07Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 sqm. as per Drawing and directed by EngineerBI01010001010000000000000515BI0100001239906.61Sqm
1298.08Providing and fixing Light Grey Granite Slab 18mm thick as per Clause 11.31 of CPWD Specifications, Volume I, 2019BI01010001010000000000000515BI010000124033.65Sqm
1308.09Providing and fixing Glass panel 18 mm thick as per Clause 9.6.4.6 of CPWD Specifications, Volume I, 2019BI01010001010000000000000515BI0100001241108.93Sqm
1318.1Providing and fixing Polycarbonate Sheet (16mm thick) as roffing including MS angles and painting as per Drawing and directed by Engineer.BI01010001010000000000000515BI0100001242294.8Sqm
1329Bill No. 9 TRAFFIC SIGNS, MARKINGS AND ROAD APPURTENCES.BI01010001010000000000000515BI0100001243
1339.01Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35-2015 .The finished surface to be level, uniform and free from streaks and holes.as per drawing and Technical specification 803BI01010001010000000000000515BI0100001244
1349.011centre line/edge line/ transverse marking and any other markings.BI01010001010000000000000515BI010000124519735Sq.m
1359.012Pedestrian crossingBI01010001010000000000000515BI01000012461347.5Sq.m
1369.013Straight ArrowsBI01010001010000000000000515BI0100001247226Nos.
1379.014Left and Right Turn ArrowsBI01010001010000000000000515BI010000124816Nos.
1389.015Straight and Left/Right Turn ArrowsBI01010001010000000000000515BI010000124918Nos.
1399.02Providing and painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces (as primary & finishing paint) as per Technical specification 1906.1.1.BI01010001010000000000000515BI010000125019130Sqm
1409.03Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 10 years warranty manufactured as per IRC :67 made of ASTM D 4956-09 Type XI micro prismatic grade sheeting fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over suitable primer and as per approved drawing and clause 801 including lettering symbols etc.BI01010001010000000000000515BI0100001251
1419.03190 cm Equilateral triangle \n(Cautionary Sign Boards)BI01010001010000000000000515BI0100001252201Nos.
1429.032STOP Sign OctagonalBI01010001010000000000000515BI0100001253215Nos.
1439.03360 cm Circular ( Mandatory Sign Boards )BI01010001010000000000000515BI010000125479Nos.
1449.04\"Advance Direction sign <0.9sq.m Direction and Place Identification Signs upto 0.9 sqm Size Board (Type XI)\nProviding and fixing of direction and place identification retro-reflectorised sign with 10 years warranty manufactured as per IRC :67 made of ASTM D 4956-09 Type XI micro prismatic grade sheeting fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with area not exceeding 0.9 sqm, with suitable back supporting frame of MS angle 40x40x6 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc\"BI01010001010000000000000515BI010000125594.05Sqm
1459.05Advance Direction sign >0.9sq.m Direction and Place Identification Signs with size more than 0.9 sqm size Board (Type XI)\nProviding and fixing of direction and place identification retro-reflectorised sign with 10 years warranty manufactured as per IRC :67 made of ASTM D 4956-09 Type XI micro prismatic grade sheeting fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with area exceeding 0.9 sqm, with suitable back supporting frame of MS angle 40x40x6 and supported on suitably designed GI pipe pole not less than 50mm NB , 2 Nos. confirming to IS 1239, firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 mm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc.BI01010001010000000000000515BI0100001256642.96Sqm
1469.06Single Chevron 600x600 Providing and fixing of retro- reflectorised cautionary, mandatory and inforyears warranty manufactured as per IRC :67 made of Type XI micro prismatic grade sheeting vide clause 801.3.4.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composite material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade Cement Concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved Drawing and MoRTH Specifications Clause 801 including lettering symbols etc.\n60cmx 60 cm rectangular (Single chevron etc.)BI01010001010000000000000515BI010000125734Nos.
1479.07Providing and fixing of retro- reflectorised cautionary, mandatory and inforyears warranty manufactured as per IRC :67 made of Type XI micro prismatic grade sheeting vide clause 801.3.4.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composite material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade Cement Concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved Drawing and MoRTH Specifications Clause 801 including lettering symbols etc.\n60cmx 45 cm rectangularBI01010001010000000000000515BI0100001258150Nos.
1489.08Providing and fixing retro-reflectorised road delineators complete as per Drawing and MoRTH Specifications Clause 805.\nObject hazard marker\nProviding and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 10 years warranty manufactured as per IRC :67 made of Type XI micro prismatic grade sheeting vide clause 801.3.4.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composite material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade Cement Concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved Drawing and MoRTH Specifications Clause 801 including lettering symbols etc.\nBI01010001010000000000000515BI0100001259166Nos.
1499.09Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 325 mm high in M 20 grade PCC on M-10 grade foundation 100 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per Technical Specification Clause 409 and IRC: 86-2018BI01010001010000000000000515BI010000126061290.2Rm
1509.1Providing and fixing Distance Indicator post including painting and printing etc all complete as per Technical Specification Clause 805.BI01010001010000000000000515BI0100001261
1519.101200m stone.BI01010001010000000000000515BI0100001262266Nos.
1529.102Reinforced cement concrete M15 grade Kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc.\n5th Kilometre stone ( precast)BI01010001010000000000000515BI010000126313Nos.
1539.103Reinforced cement concrete M 15 grade Kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc\nOrdinary kilometer stone ( precast)BI01010001010000000000000515BI010000126453Nos.
1549.11Providing RCC M-15 Boundary Stone of standard design as per IRC:25-1957, fixing in CC M-15, including finishing, lettering and painting etc all complete as per Technical Specification Clause 807.BI01010001010000000000000515BI0100001265332.43Nos.
1559.12Providing and erecting a \"W\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per MoRTH Specifications Clause 811.3 & IRC 119-2015BI01010001010000000000000515BI0100001266700Rm
1569.13Providing and fixing reflective road studs (Raised Pavement Marker) of ' category A' made out of ASA/HIPS/ABS moulded body with shanks and conforming to ASTM D 4280, strong enough to support a load of more than 13.635 T when tested in accordance with ASTM D 4280, reflective panel confirming to ASTM D 788, and reflectivity conforming to clause 804.4. including installation, drilling, fixing with adhesive etc. with 2 years warranty for the road stud as well as for in field performance as per MoRTH Specification Clause 804\nRoad Markers/Road Stud with Lense Reflector :-BI01010001010000000000000515BI010000126728578Nos.
15710Bill No. 10 HIGHWAY LIGHTINGBI01010001010000000000000515BI0100001268
15810.01Supply, installation, testing and commissioning of 8 M octagonal pole made of hot dip galvanized GI sheet 70mm top diameter,130mm bottom diameter thickness 3mm base plate dimensions of 225x225x16mm suitable for wind speed as per IS 875 part III single arm bracket 1.0 mt including foundation bolt 4 nos fixed in existing RCC foundation and junction box etc with 3Cx2.5 sqmm CU flexble cable from JB to luminaire complete 8 Meters.BI01010001010000000000000515BI01000012691146Nos.
15910.02Supply, installation, testing and commissioning of 150W LED street light output greater than 115 lumen/W 4000 – 6000 K with IP66 protection LED chip make cree/lumilled/NIchea with power factor greater than .95 at full load internal surge protection upto 8 kV and Aluminium pressure die cast powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than .98. RoHS complaint,duly wired up for use on 230V AC supply Driver compartment should be separately accessible for maintenance(LM 79 & 80 certificates from NABL accredited third party lab to be produced mentioning chip manufacturer)BI01010001010000000000000515BI01000012701146Nos.
16010.03Civil foundation : Casting of shallow RCC foundation for the 8mtr pole with M25grade cement concrete including reinforcement, levelelling course & complete in all respect as per approved drawing and direction of engineer-in -charge.BI01010001010000000000000515BI01000012711146Nos.
16110.04Supply and laying of one number PVC insulated PVC sheathed armored aluminum power cable of 1.1KV grade of the following sizes in the existing RCC/HUME/STONE WARE/GI/DWC pipe as required. 4 core 16 sq.mmBI01010001010000000000000515BI010000127239077Rm
16210.05Supply and laying of one number PVC insulated PVC sheathed armored aluminum power cable of 1.1KV grade of the following sizes in the existing RCC/HUME/STONE WARE/GI/DWC pipe as required. 3.5 core 50 sq.mmBI01010001010000000000000515BI01000012731550Rm
16310.06Providing and laying GI strip all sizes in existing trenchBI01010001010000000000000515BI01000012744608.58Kg
16410.07Supplying, testing, installing and commissioning of 40mm HDPE pipe for underground cable layingBI01010001010000000000000515BI010000127538595.7Rm
16510.08Cable Trench : Excavation upto 750mm depth width upto 300mm wide and back filliing with soft soil complete in all respect and as per direction of engineer-in -charge.BI01010001010000000000000515BI01000012767006.28Cum
16610.09Supply, erection of outdoor type panel complete with accessories and concrete foundation, service cable termination, testing and commissioning in complete:\nIncomer : 1no 63A TPN MCCB and Outgoings : 6nos of 32A TPN MCB with Astronomical Dial timer and contactor 6A MCBs for the timer.BI01010001010000000000000515BI010000127731Nos.
16710.1For Obtaining Power connection: Fees to be remitted to Electrical Inspectorate/KSEB/meter testing lab/ fire & rescue service Department(Actual amount incurred for the above items will be reimbursed on production of original Receipts). Including cost for LT supply/ Transformer & Metering box etc.BI01010001010000000000000515BI01000012781LS
16810.11Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with\ncover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required..BI01010001010000000000000515BI0100001279177Set
16910.12Supply, Installation, testing and commissioning of 16M highmast shaft in single section suitable for wind speed as per IS 875 Part-3, with raising lowering system comprising, head frame, luminaries carriage suitable to install 6 nos luminaries in symmetrical arrangement, double drum winch, 5mm diameter SS wire rope ,trailing cable, connector, integral power tool motor, manual handle, junction box, lightening finial. (Wiring material, power cables between panel and mast, MCB in base compartment are not included.)BI01010001010000000000000515BI010000128011Nos.
17010.13Supply and fixing 24mm diameter (6 numbers) foundation bolts of 750mm bolt length, 445mm pitch circle diameter manufactured from special steel along with nuts, washers, anchor plate and common template.( suitable for 16 M\nhighmast system)BI01010001010000000000000515BI010000128111set
17110.14Supply, Installation, testing and commissioning of 150W LED Flood light output > 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor >0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD <10%, power factor >0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)BI01010001010000000000000515BI010000128266Nos.
17210.15Civil foundation : Casting of shallow RCC foundation for the 16mtr pole with M25grade cement concrete including reinforcement, levelelling course & complete in all respect as per approved drawing and direction of engineer-in -charge.BI01010001010000000000000515BI010000128311Nos.
17310.16Supply, Installation, testing and commissioning of Control panel for Highmast (should be supplied same High Mast Manufacturer) including all wiring of luminaire and control wiring.BI01010001010000000000000515BI010000128411Nos.
17411Bill No. 11 ENCASING OF WATER PIPE LINEBI01010001010000000000000515BI0100001285
17511.01Earthwork in excavation of foundation for structures including pipe culverts in all types of soil including all lead & lifts complete as per Drawings and MoRTH Specifications Clauses 304 & 2903.BI01010001010000000000000515BI0100001286590.64Cum
17611.02Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100.\nRCC Grade M25 - With Batching Plant, Transit Mixer and Concrete PumpBI01010001010000000000000515BI01000012873538.16Cum
17711.03Supply, Fitting and Placing coated HYSD bar Reinforcement (Fe 500 D) in Foundation complete as per Drawing and MoRTH Specifications Section 1000 and 1600BI01010001010000000000000515BI0100001288212.29MT
17812Bill No. 12 GENERAL ITEMBI01010001010000000000000515BI0100001289
17912.01Procure (purchase) and supply brand new vehicle for employer and engineer including registration ,full comprehensive insurance(first year), number plate, road tax etc. a} Innova Type 2 Vehicle, complete as per Additional Clause 122 of Part-2, Particular Technical SpecificationsBI01010001010000000000000515BI01000012901Nos.
18012.02Vehicles running cost of fuel and POL for 3000 Km as per Additional Clause 122 of Part-2, Particular Technical SpecificationsBI01010001010000000000000515BI010000129124Veh-month
18112.03Maintenance of Type 2 Vehicles (Provided by Employer) including full comprehensive insurance, Driver's salary repairs including replacement of worn tyres, services as per manufacturer’s recommendation etc as per Additional Clause 122 of Part-2, Particular Technical SpecificationsBI01010001010000000000000515BI010000129224Veh-month
18213Bill 13 - MAINTENANCE DURING CONSTRUCTIONBI01010001010000000000000515BI0100001293
18313.1Carrying out treatment and repairs to pot holes and any necessary patching to existing bituminous carriageway surfacing as per Technical Specifications Clause 3004.BI01010001010000000000000515BI01000012946244.74Sqm
18414BILL-14 ENVIRONMENTAL SAFETY, HEALTH SAFETY AND EMP COST as per Clause A-3 (Refer EHSH Clauses- Part-2, Section -VII)BI01010001010000000000000515BI0100001295
18514.1Resources allocated to ESHS management all completed as per ESHS Clause 4BI01010001010000000000000515BI0100001296
18614.11ESHSE Manager having 10 years in designing and monitoring the implementation of ESHS management plans for construction works and in Similar works experience for 5 yearsBI01010001010000000000000515BI010000129724Month
18714.12ESHS Supervisor (one ESHS supervisor for each shift on ach Project Area), total work experience 5 years including 1-year similar work experienceBI01010001010000000000000515BI010000129824Month
18814.13Community Liaison Officer having total experience 5 years (Fluency in local Languages should be mandatory for this position)BI01010001010000000000000515BI010000129924Month
18914.2Implementation of the Health and Safety Plan all completed as per ESHS Clauses (1, 9, 21 to 25, 27 to 35, 37, 38)BI01010001010000000000000515BI0100001300
19014.21Installation silt fencing for control sediment into nearby surface water bodies, including regular maintenance for entire construction period and removal of those fence on completion of work near surface water bodiesBI01010001010000000000000515BI0100001301400Running Meter
19114.22Provide and maintenance of Personal protective equipment including nosal mask for prohibition of spread of Covid 10, as required, to all Personal Protection Equipment (PPE) pursuant to the practicesBI01010001010000000000000515BI010000130224Month
19214.23Medical Check -up – The Contractor shall organises medical check-ups carried out by a doctor or an appropriately qualified nurse for all Contractor’s Personnel prior to the initial mobilisation to the Project Area to check aptitude for the work.\nHearing tests are conducted for the contractor’s personnel exposed too noise levels above 80 dB (A) in order to establish initial audiograms. Annual test shall be carried out as per advice of the Engineer: Covid -19 test to the Contractor’s personnel as and when requiredBI01010001010000000000000515BI01000013038Quarterly
19314.24Provide and maintain first aid provisions on any work site, including : suitably stocked first aid kits: a person, respectively an adequate number of staff appointed and trained to take charge of first – aid arrangements and ensure that staff and workers are informed about first aid arrangementsBI01010001010000000000000515BI01000013041Lump Sum
19414.3Accommodation, drinking water, meals and transportation of staff all completed as per ESHS Clauses 36, 40, 41BI01010001010000000000000515BI0100001305
19514.31Accommodation, drinking water, meals and transportation of staff, Contractor shall provide to his personnel safe drinking water at all project areas. The quantity and quality of this water complies with the standards of the World health Organisations at supply points.BI01010001010000000000000515BI01000013061Lump Sum
19614.32Provided and maintain accommodation for non-resident Personnel in a camp or an alternative structure outside of the Project Areas, such as hotel or rented houseBI01010001010000000000000515BI01000013071Lump Sum
19714.33Contractor provides meals at a reasonable cost or free of charge to its Contractors Personnel per shift in a canteen area and according to a procurement systemBI01010001010000000000000515BI01000013081Lump sum
19814.4Training and local recruitment management costs all completed as per ESHS Clauses 8, 39BI01010001010000000000000515BI0100001309
19914.41Environmental management training and awareness programBI01010001010000000000000515BI01000013108Quarterly
20014.42Sanitation arrangement at campBI01010001010000000000000515BI01000013111Lump Sum
20114.5Protection of adjacent areas, biodiversity, prevention of erosion and wastewater management all completed as per ESHS Clauses 10, 11, 12, 17, 18BI01010001010000000000000515BI0100001312
20214.51Protection of adjacent areas, prevention of erosion and waste water management – The Contractor shall take necessary measures to ensure that pollution to air , water or land is prevented or, where this is not possible, reduced and mitigated as far as practicable during the construction phase. If required in the PA- ESMP the contractor will develop a pollution prevention Plan for managing e.g. atmospheric emissions and dust, e.g noise and vibrations,BI01010001010000000000000515BI01000013131Lump Sum
20314.52Installation of Oil interceptor for removal of oil and grease at vehicle wash bayBI01010001010000000000000515BI01000013141Lump Sum
20414.53Sprinkling of water for suppression of dust all along the construction areas for the entire Construction periodBI01010001010000000000000515BI01000013151Lump Sum
20514.6Traffic, noise and atmospheric emissions management, land take all completed as per ESHS Clauses 13, 14, 42, 43, 44BI01010001010000000000000515BI0100001316
20614.61Contractor should carry out or contracting the monitoring the effluent quality pursuant to the present ESHS Specifications by external accredited agency for sampling and Laboratory analysis and submit the analysis results the engineerBI01010001010000000000000515BI01000013178Sample
20714.62Contractor should carry out monitoring of environmental attributes of as per environmental monitoring plan for Construction phase (Cost obtained from NABL accredited lab)BI01010001010000000000000515BI0100001318
20814.621Air Quality Sample - 8 noBI01010001010000000000000515BI01000013198number
20914.622Surface Water Sample - 8 noBI01010001010000000000000515BI01000013208number
21014.623Ground Water Sample - 8 noBI01010001010000000000000515BI01000013218number
21114.624Noise Quality Sample - 8 noBI01010001010000000000000515BI01000013228number
21214.625Soil Quality Sample - 8 noBI01010001010000000000000515BI01000013238number
21314.63Contractor should carry out monitoring of environmental attributes of as per environmental monitoring plan for the period of operational phase / Defect Liability periodBI01010001010000000000000515BI0100001324
21414.631Air Quality Sample - 4 noBI01010001010000000000000515BI01000013254number
21514.632Surface Water Sample - 4 noBI01010001010000000000000515BI01000013264number
21614.633Ground Water Sample - 4 noBI01010001010000000000000515BI01000013274number
21714.634Noise Quality Sample - 4 noBI01010001010000000000000515BI01000013284number
21814.635Soil Quality Sample - 4 noBI01010001010000000000000515BI01000013294number
21914.7Waste and hazardous products management all completed as per EHSH Clauses 15, 26BI01010001010000000000000515BI0100001330
22014.71Identifying, collecting transporting, and treating all waste produced on Project areasBI01010001010000000000000515BI01000013311Lump Sum
22114.8Vegetation clearing and site rehabilitation all completed as per ESHS Clauses 16, 19, 20BI01010001010000000000000515BI0100001332
22214.81Site rehabilitation – the contractor will rehabilitate all Project Areas and landscapes disturbed by the works, to their original condition where possible upon completion of construction and prior to the provisional acceptance of the works. Close collaboration with all statutory stakeholders will be conducted in cooperation with the Employer during the reinstatement. This will include all temporarily acquired sites including borrow areas, camp site, etc.BI01010001010000000000000515BI01000013331Lump Sum

AI Tender Summary

OUR REF NO 26586361
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 09-03-2021
Authority
Authority Name Kerala State Transport Project
Work Description Rehabilitation And Up Gradation Of Thrissur - Kuttippuram Road ( Length Of 33 . 243 Km ) In Thrissur District
Basic Detail
Tender No KSTP/KfW/RKI PKG-III/Work/Rd-9
Bidding Type Tender
Location
City Thrissur
State Kerala
Key Dates
Publish Date 23 Feb 2021
Submission Date 09 Mar 2021
Open Date 09 Mar 2021
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
Biddrawings3.pdf
ESIAReport.pdf
Tendernotice_1.pdf
DCSDrawings.pdf
3C90ED2B-8C84-4FC9-A07A-162F54E9EFA8.html
BOQ_576775.xls
Biddrawings2.pdf
Biddrawings1.pdf
BidDoc.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 23, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 26, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 09, 2021
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 09, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 09, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Biddrawings3.pdf

pdf

ESIAReport.pdf

pdf

Tendernotice_1.pdf

pdf

DCSDrawings.pdf

html

3C90ED2B-8C84-4FC9-A07A-162F54E9EFA8.html

xls

BOQ_576775.xls

pdf

Biddrawings2.pdf

pdf

Biddrawings1.pdf

pdf

BidDoc.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders