Road Transport and Highways Government Departments Closing in 0 days TDR #26586360

Rehabilitation And Up Gradation Of Kumarakom - Nedumbassery Road ( Length 21 . 400 Km ) In Ernakulum District

Issued by Government Departments · Ernakulam, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
26 Feb 2021
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Rehabilitation And Up Gradation Of Kumarakom - Nedumbassery Road ( Length 21 . 400 Km ) In Ernakulum District

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 03-Feb-2021 Addendum1 Other 26-Feb-2021

BOQ

Name of Work: Rehabilitation and Up gradation of Kumarakom - Nedumbassery Road (Length 21.400 km) in Ernakulum District
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Bill No : 1 SITE CLEARANCE AND DISMANTLINGBI01010001010000000000000515BI0100001112
21.01Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned including removal and disposal of top organic soil not exceeding 150 mm thickness with all lead & Lift , all complete as per Technical Specification Clause 201.BI01010001010000000000000515BI01000011132.85Ha
31.02Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead - By Mechanical Means as per MoRTH Specifications Clause 202BI01010001010000000000000515BI0100001114
41.021Plain Cement ConcreteBI01010001010000000000000515BI010000111572.72Cum
51.022Reinforced Cement ConcreteBI01010001010000000000000515BI01000011163547.8Cum
61.023Dismantling RCC work of CulvertsBI01010001010000000000000515BI0100001117225.02Cum
71.024Dismantling RCC work of BridgesBI01010001010000000000000515BI01000011181334.76Cum
81.03Dismantling of flexible pavements / Non bituminous base/sub-base courses and disposal of dismantled materials with all lead and lift, stacking serviceable and unserviceable materials separately Bituminous course - By Mechanical Means as per MoRTH Specifications Clause 202BI01010001010000000000000515BI0100001119
91.031Pavement Bituminous coursesBI01010001010000000000000515BI01000011208715.05Cum
101.032Non bituminous base/sub-base coursesBI01010001010000000000000515BI01000011214406.58Cum
111.04Removal of stumps and roots of girth above 300mm and back filling to required compactionwith all lead & lift ,all complete as per Technical Specification Clause 201 and 305.BI01010001010000000000000515BI0100001122
121.041Girth from 300 mm to 600 mmBI01010001010000000000000515BI010000112360Nos.
131.042Girth from 900 mm to 1800 mmBI01010001010000000000000515BI010000112453Nos.
141.043Girth above 1800 mmBI01010001010000000000000515BI010000112588Nos.
152Bill No. 2 EARTH WORKBI01010001010000000000000515BI0100001126
162.01Excavation for roadwork in all type of soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead all complete as per Technical Specification Clause 301.BI01010001010000000000000515BI0100001127
172.011Excavation in all types of soilsBI01010001010000000000000515BI01000011281467.32Cum
182.02Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Table 300-2 and as per drawings and MoRTH Specifications Clause 305BI01010001010000000000000515BI01000011296672.93Cum
192.03Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table No. 300-2 and as per drawings and MoRTH Specifications Clause 305 & 408BI01010001010000000000000515BI010000113015659.9Cum
202.04Loosening of the ground upto a level of 500 mm below the sub-grade level, watered, graded and compacted in layers to meet requirement of Table 300-2 for Compacting original ground supporting sub-grade construction and as per MoRTH Specifications Clause 305BI01010001010000000000000515BI01000011316547.64Cum
213Bill No. 3 GRANULAR SUB-BASE AND BASE COURSESBI01010001010000000000000515BI0100001132
223.01Construction of granular sub-base by providing close graded material conforming to grading-V of table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 of Technical Specifcations.BI01010001010000000000000515BI010000113318834.5Cum
233.02Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam Specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per MoRTH Specification Clause 406.BI01010001010000000000000515BI01000011345470.2Cum
244Bill No. 4 BITUMINOUS / PQC COURSESBI01010001010000000000000515BI0100001135
254.01Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means all complete as per Clause 502.2BI01010001010000000000000515BI010000113645121.8Sqm
264.02Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.30 kg/sqm on the prepared bituminous/granular surface cleaned with mechanical broom all complete as per Clause 503.BI01010001010000000000000515BI0100001137126927Sqm
274.03Providing and laying dense bituminous macadam with 80-100 TPH HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder (VG 30) @ 4.0 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH Specification Clause No. 505 complete in all respects. \nGrading - I (37.5 mm Nominal Size) Note : The Binder content specified shall be minimum 4.0 % but will conform to requirement as per JMF. No additional cost shall be paid to the actual Binder Content as required in JMF.BI01010001010000000000000515BI01000011386298.58Cum
284.04Providing and laying Bituminous Concrete Grade II with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with Bituminous Binder minimum 5.4 % VG-30 grade, of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects..Note The Binder content specified shall be minimum 5.4% but will conform to requirement as per JMF. No additional cost shall be paid to the actual Binder Content as required in JMFBI01010001010000000000000515BI01000011393294.7Cum
294.05Construction of Dry Lean Cement Concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per Table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per Drawing and MoRTH Specifications Clause 601.BI01010001010000000000000515BI01000011409574.68Cum
304.06Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per Drawing and MoRTH Specifications Clause 602.BI01010001010000000000000515BI010000114115889.4Cum
315Bill No : 5 CULVERTSBI01010001010000000000000515BI0100001142
325.01Earth work in excavation of foundation of structures including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material in all types of soil with all lifts and leads complete as per Drawings and Technical Specification Clause 304.BI01010001010000000000000515BI010000114313509Cum
335.02Back filling behind abutments, wing walls and return walls with selected granular material of approved quality complete as per Drawing and Technical Specifications Clause 305.BI01010001010000000000000515BI01000011443185.66Cum
345.03Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.BI01010001010000000000000515BI0100001145816.03Cum
355.04Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100 \nPCC Grade M15BI01010001010000000000000515BI0100001146958.18Cum
365.05Providing & Laying Reinforced Cement Concrete of M35 Grade in Open Foundation including formwork but excluding reinforcement complete as per Drawing and Technical Specification Sections 1000, 1500, 1700 and 2100.BI01010001010000000000000515BI0100001147565.24Cum
375.06Providing & Laying Reinforced Cement Concrete of M35 Grade in Substructure including formwork but excluding reinforcement complete as per Drawing and Technical Specification Sections 1000,1500, 1700 and 2200.BI01010001010000000000000515BI0100001148533.85Cum
385.07Furnishing and Placing RCC/PSC Grade M35 in solid slab super-structure as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2300. \nBI01010001010000000000000515BI0100001149840.37Cum
395.08Supply, Fitting and Placing coated HYSD bar Reinforcement (Fe 500 D) complete as per Drawing and MoRTH Specifications Section 1000 and 1600.\nFoundation / Sub-structure / SuperstructureBI01010001010000000000000515BI0100001150155.83MT
405.09Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia PVC pipe, extending through the full width of the structure with slope of 1V : 20H towards draining face complete as per Drawing and MoRTH Specifications Clause 2706BI01010001010000000000000515BI01000011512821Nos.
415.1Provision of Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-40 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all complete as per drawing & Technical Specifications Clauses 809 & 811 and Sections 1000, 1500, 1600, 1700 and 2200.BI01010001010000000000000515BI0100001152697.28Rm
425.11Providing and fixing in position drainage spouts using 100mm dia GI pipe ,complete as per drawings and Technical Specifications Clause 2705.BI01010001010000000000000515BI0100001153302Nos.
435.12Providing and laying in position 65 mm thick wearing coat consisiting of 40 mm bituminous concrete over a 25mm thick layer of mastic asphalt over deck slab after applying prime coat complete as per drawings and MoRTH Specifications Sections 500 and 2700BI01010001010000000000000515BI01000011541400.96Sqm
445.13Providing and laying Pitching on slopes laid over prepared filter media including boulder Stone/Boulder apron laid dry in front of toe of embankment complete as per Drawing and MoRTH Specifications Clause 2504BI01010001010000000000000515BI0100001155201.19Cum
455.14Providing and laying of asphaltic plug joint to provide for horizontal movement of 25 mm and vertical movement of 2 mm, depth of joint varying from 75 mm to 100 mm, width varying from 500 mm to 750 mm ( in traffic direction), covered with a closure plate of 200 mm x 6 mm of weldable structural steel conforming to IS: 2062, asphaltic plug to consist of polymer modified bitumen binder, carefully selected single size aggregate of 12.5 mm nominal size and a heat resistant foam caulking / backer rod, all as per approved Drawings and MoRTH Specifications Section 2600BI01010001010000000000000515BI010000115664.4Rm
465.15Providing and fixing of lifting MS hook capacity of 150 kg as directed by the Engineer as per approved Drawings and MoRTH Specifications Section 1600BI01010001010000000000000515BI0100001157424Nos.
475.16Providing and fixing of Iron Step U shaped 20mm dia MS bar with capacity of 150 kg as per approved Drawings and as directed by EngineerBI01010001010000000000000515BI0100001158570Nos.
485.17Sand Filling in Foundation Trenches as per Drawing & MoRTH Specifications Clause 1210BI01010001010000000000000515BI01000011591538.77Cum
495.18Cement Concrete Blocks (size 0.5 x 0.5 x 0.5m) \nProviding and laying of apron with Cement Concrete blocks of size 0.5x0.5x0.5 m cast in-situ and made with nominal mix of M-15 grade Cement Concrete with a minimum cement content of 250 kg/cum as per IRC:21, MoRTH Specifications Clause 2503 and Sections 1000 & 1700.BI01010001010000000000000515BI0100001160674.85Cum
505.19Providing and laying filter media underneath Cement Concrete blocks of size 0.3x0.3x0.3 m cast in Cement Concrete block complete as per Drawing and MoRTH Specifications Clause 2504.BI01010001010000000000000515BI0100001161329.93Cum
515.2Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall MoRTH Specifications Clause 2507.BI01010001010000000000000515BI01000011621655.37Cum
525.21Curtain wall complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 and Clause 2507:- \nCement Concrete Grade M15BI01010001010000000000000515BI01000011631595.92Cum
535.22Flexible Apron:Providing and laying of boulder apron on river bed for protection against scour with stone boulders as per Technical Specification Clause 2503.2BI01010001010000000000000515BI0100001164682.88Cum
545.23Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100. \nRCC Grade M30 - Using Batching Plant, Transit Mixer and Concrete PumpBI01010001010000000000000515BI0100001165841.48Cum
555.24Plain/Reinforced Cement Concrete in sub-structure complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2200. \nRCC Grade M30 - Height upto 5m - using Batching Plant, Transit Mixer and Concrete PumpBI01010001010000000000000515BI0100001166905.65Cum
565.25Providing and laying Filter material underneath pitching in slopes complete as per Drawing and MoRTH Specifications Clause 2504BI01010001010000000000000515BI0100001167869.88Cum
575.26Supply, Fitting and Placing coated HYSD bar Reinforcement (Fe 500 D) complete as per Drawing and MoRTH Specifications Section 1000 and 1600BI01010001010000000000000515BI0100001168
585.261FoundationBI01010001010000000000000515BI010000116967.33MT
595.262Sub-StructureBI01010001010000000000000515BI010000117072.45MT
605.27Painting of culvert No. and span arrangement with synthetic enamel complete as per Drawing and MoRTH Specifications Clause 803BI01010001010000000000000515BI010000117132Nos.
615.28Providing 65 mm thick wearing course consistingof 40 mm thick asphaltic concrete covered by 25 mm thick mastic asphalt on top complete as per MoRTH Specifications Section 500 & 2700BI01010001010000000000000515BI010000117298Sqm
625.29Cleaning and removal of vegetation growth from structures, channel and protective works as per directions of the Engineer.BI01010001010000000000000515BI010000117328Sqm
635.3Repair of Existing Bridges by Cement Mortar 1:3 Plastering all complete as per MoRTH Specifications Section 1300.BI01010001010000000000000515BI0100001174175Sqm
645.31Guniting concrete surface with cement mortar applied with compressor after cleaning surface and spraying with epoxy complete as per directions of the Engineer.BI01010001010000000000000515BI010000117542Sqm
655.32Providing, laying & jointing RCC NP4 pipe including testing complete as per Drawing & MoRTH Specifications Section 1000 and 2900.\n1200mm diaBI01010001010000000000000515BI0100001176458.8Rm
665.33Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100\nPCC Grade M20BI01010001010000000000000515BI0100001177374.16Cum
675.34Plain/Reinforced Cement Concrete in barrier complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100\nPCC Grade M20BI01010001010000000000000515BI010000117845.2Cum
685.35Providing and laying Pitching on slopes laid over prepared filter media including boulder Stone/Boulder apron laid dry in front of toe of embankment complete as per Drawing and MoRTH Specifications Clause 2504BI01010001010000000000000515BI010000117957.43Cum
696Bill No : 6 BRIDGESBI01010001010000000000000515BI0100001180
706.01Earth work in excavation of foundation of structures including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material in all types of soil with all lifts and leads complete as per Drawings and Technical Specification Clause 304.BI01010001010000000000000515BI010000118114398.9Cum
716.02Back filling behind abutments, wing walls and return walls with selected granular material of approved quality complete as per Drawing and Technical Specifications Clause 305.BI01010001010000000000000515BI01000011824046.39Cum
726.03Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.BI01010001010000000000000515BI01000011831239.64Cum
736.04Providing & Laying Plain cement concrete of M15 Grade in leveling course below foundation complete as per drawing and Technical Specification Sections 1000, 1500 and 1700.BI01010001010000000000000515BI0100001184417.27Cum
746.05Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100.\nRCC Grade M35 - Using Batching Plant, Transit Mixer and Concrete PumpBI01010001010000000000000515BI01000011851285.68Cum
756.06Plain/Reinforced Cement Concrete in sub-structure complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100.\nRCC Grade M35 - Using Batching Plant, Transit Mixer and Concrete PumpBI01010001010000000000000515BI0100001186759.17Cum
766.07Furnishing and Placing RCC/PSC Grade M35 Using Batching Plant, Transit Mixer and Concrete Pump as per drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2300. For solid slab super-structure - Height 5m to 10m.BI01010001010000000000000515BI01000011871121.85Cum
776.08Supply, Fitting and Placing coated HYSD bar Reinforcement (Fe 500 D) complete as per Drawing and MoRTH Specifications Section 1000 and 1600\nFoundation / Sub-structure / SuperstructureBI01010001010000000000000515BI0100001188
786.081For sub-structureBI01010001010000000000000515BI010000118965.36MT
796.082For super-structureBI01010001010000000000000515BI0100001190103.94MT
806.083For foundationsBI01010001010000000000000515BI0100001191115.71MT
816.09Providing and laying of asphaltic plug joint to provide for horizontal movement of 25 mm and vertical movement of 2 mm, depth of joint varying from 75 mm to 100 mm, width varying from 500 mm to 750 mm ( in traffic direction), covered with a closure plate of 200 mm x 6 mm of weldable structural steel conforming to IS: 2062, asphaltic plug to consist of polymer modified bitumen binder, carefully selected single size aggregate of 12.5 mm nominal size and a heat resistant foam caulking / backer rod, all as per approved Drawings and MoRTH Specifications Section 2600BI01010001010000000000000515BI0100001192111.2Rm
826.1Providing and fixing in position drainage spouts using 100mm dia GI pipe ,complete as per drawings and Technical Specifications Clause 2705.BI01010001010000000000000515BI010000119366Nos.
836.11Providing and laying in position 65 mm thick wearing coat consisiting of 40 mm bituminous concrete over a 25mm thick layer of mastic asphalt over deck slab after applying prime coat complete as per drawings and MoRTH Specifications Sections 500 and 2700BI01010001010000000000000515BI01000011941072.69Sqm
846.12Providing and fixing Tar paper bearing complete as per drawing and Technical Specifications Clause 2011.BI01010001010000000000000515BI010000119528.8Sqm
856.13Furnishing and Placing Reinforced Cement Concrete Grade M25 Using Concrete Mixer in super-structure as per Drawing and MoRTH Specifications Section 410, 1000, 1500, 1600 & 1700, \nRaised -FootpathBI01010001010000000000000515BI010000119695.22Cum
866.14Sand Filling in Foundation Trenches as per Drawing & MoRTH Specifications Clause 1210BI01010001010000000000000515BI01000011971347.8Cum
876.15Provision of Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-40 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all complete as per drawing & Technical Specifications Clauses 809 & 811 and Sections 1000, 1500, 1600, 1700 and 2200.BI01010001010000000000000515BI0100001198312.7Rm
886.16PCC M15 Grade leveling course below approach slab complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1600 and 2700.BI01010001010000000000000515BI010000119951.84Cum
896.17Reinforced Cement Concrete Grade M30 approach slab including reinforcement and formwork complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1600 and 2700.BI01010001010000000000000515BI0100001200100.8Cum
906.18Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia PVC pipe, extending through the full width of the structure with slope of 1V : 20H towards draining face complete as per Drawing and MoRTH Specifications Clause 2706BI01010001010000000000000515BI01000012012066Nos.
916.19Furnishing and Placing Reinforced Cement Concrete Grade M25 Using Concrete Mixer in super-structure as per Drawing and MoRTH Specifications Section 400, 1000, 1500, 1600 & 1700, \nKerbBI01010001010000000000000515BI0100001202211.6Rm
926.2Stone masonry work in cement mortar 1:3 for Foundation and substructure complete as per drawing and & MORT&H Specifications sections 1600, 2200 & clause 2100.BI01010001010000000000000515BI0100001203198.66Rm
936.21Cement Concrete Blocks (size 0.5 x 0.5 x 0.5m) \nProviding and laying of apron with Cement Concrete blocks of size 0.5x0.5x0.5 m cast in-situ and made with nominal mix of M-15 grade Cement Concrete with a minimum cement content of 250 kg/cum as per IRC:21, MoRTH Specifications Clause 2503 and Section 1000 & 1700.BI01010001010000000000000515BI01000012041691.75Cum
946.22Providing and laying filter media underneath Cement Concrete blocks of size 0.3x0.3 x0.3 m cast in cement concrete block complete as per drawing and MoRTH Specifications Clause 2504.BI01010001010000000000000515BI0100001205349.19Cum
956.23Construction of flexible apron 1 m thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall MoRTH Specifications Clause 2507.BI01010001010000000000000515BI01000012061547.27Cum
966.24Curtain/Toe wall complete as per drawing and MoRTH Specifications Section 1000,1500,1700 and clause 2507- Cement concrete Grade M20BI01010001010000000000000515BI0100001207511.02Cum
976.25Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and MoRTH Specifications Clause 2504.BI01010001010000000000000515BI0100001208716.1Cum
986.26Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100. \nRCC Grade M30 - Using Batching Plant, Transit Mixer and Concrete PumpBI01010001010000000000000515BI0100001209857.2Cum
996.27Plain/Reinforced Cement Concrete in sub-structure complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2200. \nRCC Grade M30 - Height upto 5m - using Batching Plant, Transit Mixer and Concrete PumpBI01010001010000000000000515BI0100001210867.76Cum
1006.28Supply, Fitting and Placing coated HYSD bar Reinforcement (Fe 500 D) complete as per Drawing and MoRTH Specifications Section 1000,1900 2100 & 2200BI01010001010000000000000515BI0100001211
1016.281FoundationBI01010001010000000000000515BI010000121268.58MT
1026.282Sub-StructureBI01010001010000000000000515BI010000121369.42MT
1036.29Providing and laying in position 65 mm thick wearing coat consisiting of 40 mm bituminous concrete over a 25mm thick layer of mastic asphalt over deck slab after applying prime coat complete as per drawings and MoRTH Specifications Sections 500 and 2700BI01010001010000000000000515BI0100001214467.5Sqm
1046.3Cleaning and removal of vegetation growth from structures, channel and protective works as per directions of the Engineer.BI01010001010000000000000515BI0100001215100Sqm
1056.31Repair of Existing Bridges by Cement Mortar 1:3 Plastering all complete as per MoRTH Specifications Section 1300.BI01010001010000000000000515BI010000121625Sqm
1066.32Providing & laying stone pitching on slopes for erosion protection and open drain and drain joining rain water harvesting pit complete as per Drawing and MoRTH Specifications Section 2500 and as directed by the Engineer.BI01010001010000000000000515BI0100001217300Sqm
1077Bill No. 7 DRAINAGE AND PROTECTIVE WORKSBI01010001010000000000000515BI0100001218
1087.01Earthwork in excavation in all types of soil and rock with all lifts and leads complete as per Drawings and Technical Specification Clause 304.BI01010001010000000000000515BI0100001219
1097.011In all types of soilBI01010001010000000000000515BI01000012207057.7Cum
1107.02Construction of open/covered drain complete as per drg.BI01010001010000000000000515BI0100001221
1117.021Plain/Reinforced Cement Concrete in drain Foundation complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100. \nPCC Grade M15\nBI01010001010000000000000515BI0100001222703.88Cum
1127.022Providing and laying PCC/RCC M-20 grade for lined drains. including the cost of formwork but excluding the cost of reinforcement complete as per Drawing and MoRTH Specifications Section 1000, 1500 and 1700.BI01010001010000000000000515BI01000012233251.56Cum
1137.023Providing & fixing in position coated HYSD / TMT Fe 500 D grade bar reinforcement in base, walls and slab of RCC drains complete as per Drawing and MoRTH Specifications Section 1600.BI01010001010000000000000515BI0100001224162.58MT
1147.024Providing and laying RCC pipe 100 mm dia. complete as per Drawing and directed by EngineerBI01010001010000000000000515BI0100001225118.8Rm
1158Bill No. 8 BUS SHELTERBI01010001010000000000000515BI0100001226
1168.01Foundation for Wall and ColumnBI01010001010000000000000515BI0100001227
1178.011a) Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100. \nPCC Grade M15\nBI01010001010000000000000515BI010000122826.26Cum
1188.012Brick Masonry Work in Cement Mortar 1:4 in Foundation complete excluding Pointing and Plastering, as per Drawing and MoRTH Specifications Section 1300 for 1 stepBI01010001010000000000000515BI010000122919.27Cum
1198.013Brick Masonry Work in Cement Mortar 1:4 in Foundation complete excluding Pointing and Plastering, as per Drawing and MoRTH Specifications Section 1300 for 2nd stepBI01010001010000000000000515BI010000123012.27Cum
1208.02Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and MoRTH Specifications Section 1300BI01010001010000000000000515BI010000123190.88Cum
1218.03C:C floor for Platform / Precast Interlocking Paver BlocksBI01010001010000000000000515BI0100001232
1228.031Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100. \nPCC Grade M15BI01010001010000000000000515BI010000123337.42Cum
1238.032Providing and laying Anti-skid Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS: 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.BI01010001010000000000000515BI0100001234249.48Sqm
1248.04Sitting arrangement for PassengerBI01010001010000000000000515BI0100001235
1258.041Brick Masonry Work in Cement Mortar 1:3 in Foundation complete excluding Pointing and Plastering, as per Drawing and MoRTH Specifications Section 1300BI01010001010000000000000515BI01000012368.86Cum
1268.042Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge.With granite stone of area less than 0.50 sqm.BI01010001010000000000000515BI010000123721.6Sqm
1278.05Plastering with cement mortar (1:3 ) on brick work in sub-structure as per MoRTH Specifications Section 1300BI01010001010000000000000515BI0100001238858.89Sqm
1288.06Providing 10 mm thick plaster of Paris above brick wall as per Drawing and directed by EngineerBI01010001010000000000000515BI0100001239858.89Sqm
1298.07Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 sqm. as per Drawing and directed by EngineerBI01010001010000000000000515BI0100001240858.89Sqm
1308.08Providing and fixing Light Grey Granite Slab 18mm thick as per Clause 11.31 of CPWD Specifications, Volume I, 2019BI01010001010000000000000515BI010000124131.88Sqm
1318.09Providing and fixing Glass panel 18 mm thick as per Clause 9.6.4.6 of CPWD Specifications, Volume I, 2019BI01010001010000000000000515BI0100001242103.19Sqm
1328.1Providing and fixing Polycarbonate Sheet (16mm thick) as roffing including MS angles and painting as per Drawing and directed by Engineer.BI01010001010000000000000515BI0100001243279.28Sqm
1339Bill No. 9 TRAFFIC SIGNS, MARKINGS AND ROAD APPURTENCES.BI01010001010000000000000515BI0100001244
1349.01Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35-2015 .The finished surface to be level, uniform and free from streaks and holes.as per drawing and Technical specification 803BI01010001010000000000000515BI0100001245
1359.011centre line/edge line/ transverse marking and any other markings.BI01010001010000000000000515BI01000012469915Sq.m
1369.012Pedestrian crossingBI01010001010000000000000515BI0100001247735Sq.m
1379.013Straight ArrowsBI01010001010000000000000515BI010000124817Nos.
1389.014Straight and Left/Right Turn ArrowsBI01010001010000000000000515BI010000124917Nos.
1399.02Providing and painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces (as primary & finishing paint) as per Technical specification 1906.1.1.BI01010001010000000000000515BI01000012501872.36Sqm
1409.03Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 10 years warranty manufactured as per IRC :67 made of ASTM D 4956-09 Type XI micro prismatic grade sheeting fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over suitable primer and as per approved drawing and clause 801 including lettering symbols etc.BI01010001010000000000000515BI0100001251
1419.03190 cm Equilateral triangle \n(Cautionary Sign Boards)BI01010001010000000000000515BI0100001252177Nos.
1429.032STOP Sign OctagonalBI01010001010000000000000515BI010000125396Nos.
1439.03360 cm Circular ( Mandatory Sign Boards )BI01010001010000000000000515BI010000125435Nos.
1449.04\"Advance Direction sign <0.9sq.m Direction and Place Identification Signs upto 0.9 sqm Size Board (Type XI)\nProviding and fixing of direction and place identification retro-reflectorised sign with 10 years warranty manufactured as per IRC :67 made of ASTM D 4956-09 Type XI micro prismatic grade sheeting fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with area not exceeding 0.9 sqm, with suitable back supporting frame of MS angle 40x40x6 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc\"BI01010001010000000000000515BI010000125543.56Sqm
1459.05Advance Direction sign >0.9sq.m Direction and Place Identification Signs with size more than 0.9 sqm size Board (Type XI)\nProviding and fixing of direction and place identification retro-reflectorised sign with 10 years warranty manufactured as per IRC :67 made of ASTM D 4956-09 Type XI micro prismatic grade sheeting fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with area exceeding 0.9 sqm, with suitable back supporting frame of MS angle 40x40x6 and supported on suitably designed GI pipe pole not less than 50mm NB , 2 Nos. confirming to IS 1239, firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 mm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc.BI01010001010000000000000515BI0100001256280.68Sqm
1469.06Single Chevron 600x600 Providing and fixing of retro- reflectorised cautionary, mandatory and inforyears warranty manufactured as per IRC :67 made of Type XI micro prismatic grade sheeting vide clause 801.3.4.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composite material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade Cement Concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved Drawing and MoRTH Specifications Clause 801 including lettering symbols etc.\n60cmx 60 cm rectangular (Single chevron etc.)BI01010001010000000000000515BI0100001257206Nos.
1479.07Providing and fixing of retro- reflectorised cautionary, mandatory and inforyears warranty manufactured as per IRC :67 made of Type XI micro prismatic grade sheeting vide clause 801.3.4.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composite material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade Cement Concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved Drawing and MoRTH Specifications Clause 801 including lettering symbols etc.\n60cmx 45 cm rectangularBI01010001010000000000000515BI010000125881Nos.
1489.08Providing and fixing retro-reflectorised road delineators complete as per Drawing and MoRTH Specifications Clause 805.\nObject hazard marker\nProviding and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 10 years warranty manufactured as per IRC :67 made of Type XI micro prismatic grade sheeting vide clause 801.3.4.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composite material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade Cement Concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved Drawing and MoRTH Specifications Clause 801 including lettering symbols etc.\nBI01010001010000000000000515BI0100001259174Nos.
1499.09Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 325 mm high in M 20 grade PCC on M-10 grade foundation 100 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per Technical Specification Clause 409 and IRC: 86-2018BI01010001010000000000000515BI01000012605944Rm
1509.1Providing and fixing Distance Indicator post including painting and printing etc all complete as per Technical Specification Clause 805.BI01010001010000000000000515BI0100001261
1519.101i) 200m stone.BI01010001010000000000000515BI0100001262172Nos.
1529.102ii) Reinforced cement concrete M15 grade Kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc.\n5th Kilometre stone ( precast)BI01010001010000000000000515BI01000012639Nos.
1539.103iii) \tReinforces cement concrete M 15 grade Kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc\nOrdinary kilometer stone ( precast)BI01010001010000000000000515BI010000126434Nos.
1549.11Providing RCC M-15 Boundary Stone of standard design as per IRC:25-1957, fixing in CC M-15, including finishing, lettering and painting etc all complete as per Technical Specification Clause 807.BI01010001010000000000000515BI0100001265214Nos.
1559.12Providing and erecting a \"W\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per MoRTH Specifications Clause 811.3 & IRC 119-2015BI01010001010000000000000515BI0100001266700Rm
1569.13Providing and fixing reflective road studs (Raised Pavement Marker) of ' category A' made out of ASA/HIPS/ABS moulded body with shanks and conforming to ASTM D 4280, strong enough to support a load of more than 13.635 T when tested in accordance with ASTM D 4280, reflective panel confirming to ASTM D 788, and reflectivity conforming to clause 804.4. including installation, drilling, fixing with adhesive etc. with 2 years warranty for the road stud as well as for in field performance as per MoRTH Specification Clause 804\nRoad Markers/Road Stud with Lense Reflector :-BI01010001010000000000000515BI01000012679119.64Nos.
1579.14Convex Glass as per direction of engineer-in -charge.BI01010001010000000000000515BI010000126836Nos.
15810Bill No. 10 HIGHWAY LIGHTINGBI01010001010000000000000515BI0100001269
15910.01Supply, installation, testing and commissioning of 8 M octagonal pole made of hot dip galvanized GI sheet 70mm top diameter,130mm bottom diameter thickness 3mm base plate dimensions of 225x225x16mm suitable for wind speed as per IS 875 part III single arm bracket 1.0 mt including foundation bolt 4 nos fixed in existing RCC foundation and junction box etc with 3Cx2.5 sqmm CU flexble cable from JB to luminaire complete 8 Meters.BI01010001010000000000000515BI0100001270428Nos.
16010.02Supply, installation, testing and commissioning of 150W LED street light output greater than 115 lumen/W 4000 – 6000 K with IP66 protection LED chip make cree/lumilled/NIchea with power factor greater than .95 at full load internal surge protection upto 8 kV and Aluminium pressure die cast powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than .98. RoHS complaint,duly wired up for use on 230V AC supply Driver compartment should be separately accessible for maintenance(LM 79 & 80 certificates from NABL accredited third party lab to be produced mentioning chip manufacturer)BI01010001010000000000000515BI0100001271428Nos.
16110.03Civil foundation : Casting of shallow RCC foundation for the 8mtr pole with M25grade cement concrete including reinforcement, levelelling course & complete in all respect as per approved drawing and direction of engineer-in -charge.BI01010001010000000000000515BI0100001272428Nos.
16210.04Supply and laying of one number PVC insulated PVC sheathed armored aluminum power cable of 1.1KV grade of the following sizes in the existing RCC/HUME/STONE WARE/GI/DWC pipe as required. 4 core 16 sq.mmBI01010001010000000000000515BI010000127316778Rm
16310.05Supply and laying of one number PVC insulated PVC sheathed armored aluminum power cable of 1.1KV grade of the following sizes in the existing RCC/HUME/STONE WARE/GI/DWC pipe as required. 3.5 core 50 sq.mmBI01010001010000000000000515BI0100001274800Rm
16410.06Providing and laying GI strip all sizes in existing trenchBI01010001010000000000000515BI01000012751854.44Kg
16510.07Supplying, testing, installing and commissioning of 40mm HDPE pipe for underground cable layingBI01010001010000000000000515BI010000127616699.1Rm
16610.08Cable Trench : Excavation upto 750mm depth width upto 300mm wide and back filliing with soft soil complete in all respect and as per direction of engineer-in -charge.BI01010001010000000000000515BI01000012772819.25Cum
16710.09Supply, erection of outdoor type panel complete with accessories and concrete foundation, service cable termination, testing and commissioning in complete:\nIncomer : 1no 63A TPN MCCB and Outgoings : 6nos of 32A TPN MCB with Astronomical Dial timer and contactor 6A MCBs for the timer.BI01010001010000000000000515BI010000127813Nos.
16810.1For Obtaining Power connection: Fees to be remitted to Electrical Inspectorate/KSEB/meter testing lab/ fire & rescue service Department(Actual amount incurred for the above items will be reimbursed on production of original Receipts). Including cost for LT supply/ Transformer & Metering box etc.BI01010001010000000000000515BI01000012791LS
16910.11Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with\ncover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required..BI01010001010000000000000515BI010000128069Set
17010.12Supply, Installation, testing and commissioning of 16M highmast shaft in single section suitable for wind speed as per IS 875 Part-3, with raising lowering system comprising, head frame, luminaries carriage suitable to install 6 nos luminaries in symmetrical arrangement, double drum winch, 5mm diameter SS wire rope ,trailing cable, connector, integral power tool motor, manual handle, junction box, lightening finial. (Wiring material, power cables between panel and mast, MCB in base compartment are not included.)BI01010001010000000000000515BI01000012815Nos.
17110.13Supply and fixing 24mm diameter (6 numbers) foundation bolts of 750mm bolt length, 445mm pitch circle diameter manufactured from special steel along with nuts, washers, anchor plate and common template.( suitable for 16 M\nhighmast system)BI01010001010000000000000515BI01000012825set
17210.14Supply, Installation, testing and commissioning of 150W LED Flood light output > 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor >0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD <10%, power factor >0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)BI01010001010000000000000515BI010000128330Nos.
17310.15Civil foundation : Casting of shallow RCC foundation for the 16mtr pole with M25grade cement concrete including reinforcement, levelelling course & complete in all respect as per approved drawing and direction of engineer-in -charge.BI01010001010000000000000515BI01000012845Nos.
17410.16Supply, Installation, testing and commissioning of Control panel for Highmast (should be supplied same High Mast Manufacturer) including all wiring of luminaire and control wiring.BI01010001010000000000000515BI01000012855Nos.
17511Bill.no. 11 Encasing of water pipe LineBI01010001010000000000000515BI0100001286
17611.01Earthwork in excavation of foundation for structures including pipe culverts in all types of soil including all lead & lifts complete as per Drawings and MoRTH Specifications Clauses 304 & 2903.BI01010001010000000000000515BI01000012874287.5Cum
17711.02Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and MoRTH Specifications Section 1000, 1500, 1700 & 2100.\nRCC Grade M25 - With Batching Plant, Transit Mixer and Concrete PumpBI01010001010000000000000515BI01000012883669Cum
17811.03Supply, Fitting and Placing coated HYSD bar Reinforcement (Fe 500 D) in Foundation complete as per Drawing and MoRTH Specifications Section 1000 and 1600BI01010001010000000000000515BI0100001289220.14MT
17912Bill.no. 12 General ItemBI01010001010000000000000515BI0100001290
18012.01Procure (purchase) and supply brand new vehicle for employer and engineer including registration ,full comprehensive insurance(first year), number plate, road tax etc. a} Innova Type 2 Vehicle, complete as per Additional Clause 122 of Part-2, Particular Technical SpecificationsBI01010001010000000000000515BI01000012911Nos.
18112.02Vehicles running cost of fuel and POL for 3000 Km as per Additional Clause 122 of Part-2, Particular Technical SpecificationsBI01010001010000000000000515BI010000129218Veh-month
18212.03Maintenance of Type 2 Vehicles (Provided by Employer) including full comprehensive insurance, Driver's salary repairs including replacement of worn tyres, services as per manufacturer’s recommendation etc as per Additional Clause 122 of Part-2, Particular Technical SpecificationsBI01010001010000000000000515BI010000129318Veh-month
18313Bill 13 - MAINTENANCE DURING CONSTRUCTIONBI01010001010000000000000515BI0100001294
18413.1Carrying out treatment and repairs to pot holes and any necessary patching to existing bituminous carriageway surfacing as per Technical Specifications Clause 3004.BI01010001010000000000000515BI01000012953015.07Sqm
18514Bill 14 -ENVIRONMENTAL SAFETY, HEALTH SAFETY AND EMP COSTBI01010001010000000000000515BI0100001296
18614.1Resources allocated to ESHS managementBI01010001010000000000000515BI0100001297
18714.11ESHSE Manager having 10 years in designing and monitoring the implementation of ESHS management plans for construction works and in Similar works experience for 5 yearsBI01010001010000000000000515BI010000129818Month
18814.12ESHS Supervisor (one ESHS supervisor for each shift on ach Project Area), total work experience 5 years including 1-year similar work experienceBI01010001010000000000000515BI010000129918Month
18914.13Community Liaison Officer having total experience 5 years (Fluency in local Languages should be mandatory for this position)BI01010001010000000000000515BI010000130018Month
19014.2Implementation of health and Safety Plan:BI01010001010000000000000515BI0100001301
19114.21Installation silt fencing for control sediment into nearby surface water bodies, including regular maintenance for entire construction period and removal of those fence on completion of work near surface water bodiesBI01010001010000000000000515BI0100001302400Running Meter
19214.22Provide and maintenance of Personal protective equipment including nosal mask for prohibition of spread of Covid 10, as required, to all Personal Protection Equipment (PPE) pursuant to the practicesBI01010001010000000000000515BI010000130318Month
19314.23Medical Check -up – The Contractor shall organises medical check-ups carried out by a doctor or an appropriately qualified nurse for all Contractor’s Personnel prior to the initial mobilisation to the Project Area to check aptitude for the work.\nHearing tests are conducted for the contractor’s personnel exposed too noise levels above 80 dB (A) in order to establish initial audiograms. Annual test shall be carried out as per advice of the Engineer: Covid -19 test to the Contractor’s personnel as and when requiredBI01010001010000000000000515BI01000013046Quarterly
19414.24Provide and maintain first aid provisions on any work site, including : suitably stocked first aid kits: a person, respectively an adequate number of staff appointed and trained to take charge of first – aid arrangements and ensure that staff and workers are informed about first aid arrangementsBI01010001010000000000000515BI01000013051Lump Sum
19514.3Accommodation, drinking water, meals, and transportation of staffBI01010001010000000000000515BI0100001306
19614.31Accommodation, drinking water, meals and transportation of staff, Contractor shall provide to his personnel safe drinking water at all project areas. The quantity and quality of this water complies with the standards of the World health Organisations at supply points.BI01010001010000000000000515BI01000013071Lump sum
19714.32Provided and maintain accommodation for non-resident Personnel in a camp or an alternative structure outside of the Project Areas, such as hotel or rented houseBI01010001010000000000000515BI01000013081Lump Sum
19814.33Contractor provides meals at a reasonable cost or free of charge to its Contractors Personnel per shift in a canteen area and according to a procurement systemBI01010001010000000000000515BI01000013091Lump sum
19914.4Training and Local Requirement management CostsBI01010001010000000000000515BI0100001310
20014.41Environmental management training and awareness programBI01010001010000000000000515BI01000013116Quarterly
20114.42Sanitation arrangement at campBI01010001010000000000000515BI01000013121Lump Sum
20214.5Protection of adjacent areas, biodiversity, prevention of erosion and wastewater managementBI01010001010000000000000515BI0100001313
20314.51Protection of adjacent areas, prevention of erosion and waste water management – The Contractor shall take necessary measures to ensure that pollution to air , water or land is prevented or, where this is not possible, reduced and mitigated as far as practicable during the construction phase. If required in the PA- ESMP the contractor will develop a pollution prevention Plan for managing e.g. atmospheric emissions and dust, e.g noise and vibrations,BI01010001010000000000000515BI01000013141Lump Sum
20414.52Installation of Oil interceptor for removal of oil and grease at vehicle wash bayBI01010001010000000000000515BI01000013151Lump Sum
20514.53Sprinkling of water for suppression of dust all along the construction areas for the entire Construction periodBI01010001010000000000000515BI01000013161Lump Sum
20614.6Traffic, noise and atmospheric emissions management, land takeBI01010001010000000000000515BI0100001317
20714.61Contractor should carry out or contracting the monitoring the effluent quality pursuant to the present ESHS Specifications by external accredited agency for sampling and Laboratory analysis and submit the analysis results the engineerBI01010001010000000000000515BI01000013186Sample
20814.62Contractor should carry out monitoring of environmental attributes of as per environmental monitoring plan for Construction phase (Cost obtained from NABL accredited lab)BI01010001010000000000000515BI0100001319
20914.621Air Quality Sample - 6 noBI01010001010000000000000515BI01000013206number
21014.622Surface Water Sample - 6 noBI01010001010000000000000515BI01000013216number
21114.623Ground Water Sample - 6 noBI01010001010000000000000515BI01000013226number
21214.624Noise Quality Sample - 6 noBI01010001010000000000000515BI01000013236number
21314.625Soil Quality Sample - 6 noBI01010001010000000000000515BI01000013246number
21414.63Contractor should carry out monitoring of environmental attributes of as per environmental monitoring plan for the period of operational phase / Defect Liability periodBI01010001010000000000000515BI0100001325
21514.631Air Quality Sample - 3 noBI01010001010000000000000515BI01000013263number
21614.632Surface Water Sample - 3 noBI01010001010000000000000515BI01000013273number
21714.633Ground Water Sample - 3 noBI01010001010000000000000515BI01000013283number
21814.634Noise Quality Sample - 3 noBI01010001010000000000000515BI01000013293number
21914.635Soil Quality Sample - 3 noBI01010001010000000000000515BI01000013303number
22014.7Solid Wate /hazardous products managementBI01010001010000000000000515BI0100001331
22114.71Identifying, collecting transporting, and treating all waste produced on Project areasBI01010001010000000000000515BI01000013321Lump Sum
22214.8Vegetation clearing and site rehabilitationBI01010001010000000000000515BI0100001333
22314.81Site rehabilitation – the contractor will rehabilitate all Project Areas and landscapes disturbed by the works, to their original condition where possible upon completion of construction and prior to the provisional acceptance of the works. Close collaboration with all statutory stakeholders will be conducted in cooperation with the Employer during the reinstatement. This will include all temporarily acquired sites including borrow areas, camp site, etc.BI01010001010000000000000515BI01000013341Lump Sum

AI Tender Summary

OUR REF NO 26586360
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 26-02-2021
Authority
Authority Name Kerala State Transport Project
Work Description Rehabilitation And Up Gradation Of Kumarakom - Nedumbassery Road ( Length 21 . 400 Km ) In Ernakulum District
Basic Detail
Tender No KSTP/KfW/RKI PKG-III/Work/Rd-4
Bidding Type Tender
Location
City Ernakulam
State Kerala
Key Dates
Publish Date 03 Feb 2021
Submission Date 26 Feb 2021
Open Date 26 Feb 2021
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
742EEE94-50DA-4853-AC40-6659DE8072BB.html
BidDrg1.pdf
BidDrg4.pdf
BOQ_576739.xls
Tendernotice_1.pdf
BidDoc.pdf
BidDrg6.pdf
BidDrg2.pdf
BidDrg3.pdf
ESIAReport.pdf
DCSDrawings.pdf
BidDrg5.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 03, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 26, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 26, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 26, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

742EEE94-50DA-4853-AC40-6659DE8072BB.html

pdf

BidDrg1.pdf

pdf

BidDrg4.pdf

xls

BOQ_576739.xls

pdf

Tendernotice_1.pdf

pdf

BidDoc.pdf

pdf

BidDrg6.pdf

pdf

BidDrg2.pdf

pdf

BidDrg3.pdf

pdf

ESIAReport.pdf

pdf

DCSDrawings.pdf

pdf

BidDrg5.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender