Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #26568695

Rate Contract Of Angiography And Angioplasty Items

Issued by Boards / Undertakings / PSU · MEMBER SECRETARY RMRS MBGH UDAIPUR, Rajasthan
Tender Value
Ref. Documents
Estimated cost
Bid Submission
11 Feb 2021
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
400
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
MEMBER SECRETARY RMRS MBGH UDAIPUR → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Rate Contract Of Angiography And Angioplasty Items-1 ANGIOGRAPHY/ ANGIOPLASTY ITEMS 2 FEMORAL INTRODUCER SHEATH WITH PUNCTURE NEEDLE FOR ADULTS (size 4 Fr. To 11Fr.) (standard Length)n• Sizes 4 French/ 5 French/ 6 French/ 7 French/ 8 French/ 9 French/10 French/11Frenchn• 10-11 cm Longn• Pack must include 18G, 6-7.5 cm long puncture needle and 0.035 inch guide wire n• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantn• With dilator-hub lock mechanism to prevent its back- out during insertionn• With smooth and resistance free insertion 3 Radial glide sheath INTRODUCERnSHEATH with outer diameter one Fr size Under. (6 Fr sheath with outer diameter of 5 Fr)n• Size 5 French/ 6 French/ 7 Frenchn• Sheath should be between 10-16 cm longn• 0.021 and 0.025 inch guide wire compatiblen• Hydrophilic Coatingn• 20-22 G needle length 2’ inchn• Guide Wire Should be available in 3 forms n• A.) Plastic Short AnglennB) Flex Straight nC) Nitinol Floppyn• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantn• With dilator-hub lock mechanism to prevent its back-out during insertionn• With smooth and resistance free insertionn 4 LONG INTRODUCER SHEATH (20-50 cm long) (size 4Fr. -11Fr.)n• Size 4 French/ 5 French/ 6 French/ 7 French/ 8 French/ 9 French/ 10 French/ 11 Frenchn• Sheath should be between 20-50 cm longn• 0.035 or 0.038 inch guide wire and compatibility n• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantn• With dilator-hub lock mechanism to prevent its back-out during insertionn• With smooth and resistance free insertionn 5 TRANS RADIAL INTRODUCER SHEATHS 4F-7F-n• Size 4 French/ 5 French/ 6 French/7 Frenchn• 07-10 cm longn• Guide Wire Should be available in 2 forms n• A.) Plastic Short AnglenB) Flex Straight n• Pack must include Surflash like puncture needle with plastic IV catheter, 20G – 22G, Length 2 inches n• 0.025 inch Hydrophilic Miniplastic guide wire (Length 45 cm) and compatibilityn• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantn• With Dilator hub-lock mechanism to prevent its back-out during insertionn• With smooth and resistance free insertionn n 6 LONG BRAIDED INTRODUCER SHEATH-n• Size 6 French/ 7 French/ 8 French/ 9 French and aboven• Should be 30-90 cm and aboven• 0.021 or 0.025 inch guide wire compatiblen• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantnn• With dilator-hub lock mechanism to prevent its back-out during insertionnn 7 FEMORAL INTRODUCER SHEATH WITH PUNCTURE NEEDLE FOR ADULTS (size 4 Fr. To 11Fr.) (standard Length)n• Sizes 4 French/ 5 French/ 6 French/ 7 French/ 8 French/ 9 French/10 French/11Frenchn• 10-11 cm Longn• Pack must include 18G, 6-7.5 cm long puncture needle and 0.035 inch guide wire n• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantn• With dilator-hub lock mechanism to prevent its back- out during insertionn• With smooth and resistance free insertionn• Integral side port with attached 3-way stopcock. The hub and sheath should be made of same material and there should be no joint between hub and sheath.nn 8 TRANS RADIAL INTRODUCER SHEATHS 4F-7F-n• Size 4 French/ 5 French/ 6 French/7 Frenchn• 07-10 cm longn• Guide Wire Should be available in 2 forms n• A.) Plastic Short AnglenB) Flex Straight n• Pack must include Surflash like puncture needle with plastic IV catheter, 20G – 22G, Length 2 inches n• 0.025 inch Hydrophilic Miniplastic guide wire (Length 45 cm) and compatibilityn• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantn• With Dilator hub-lock mechanism to prevent its back-out during insertionn• With smooth and resistance free insertionn• Integral side port with attached 3-way stopcock. The hub and sheath should be made of same material and there should be no joint between hub and sheath.nn n 9 TRANSRADIAL DIAGNOSTIC CORONARY CATHETER n• 4 French/5 French/6French/ n• diagnostic coronary catheters must be with various curves and shapes like ULTRA CURVE, IKARI CURVE, TRANSFORMER CURVE, TRACTIVE CURVE, and various shapes like tig II, jacky, sarah shapes etc. and length dedicated for trans radial coronary angiography and brachial approach also n• Soft tip compression (GF) for atraumatic tip should be equal to or less then 100n• Soft atraumatic, radiopaque tip with increased visibilityn• Double-braided stainless steel mesh middle layer for 1:1 torque controln• kink resistance nn n 10 SPECIAL SWAN GANZ CATHETER WITH Safety Wedge:-n• 4 F catheter should allow the passage of at least 0.021 inch, 5F-0.025 inch, 6 F-0.035 inch and 7 F, 8F-0.038 inch, PTFE/ hydrophilic guide wiren• Must be available in 4F, 5F, 6F, and 7F and 8 Fr. Sizesn• Catheter should be tapered at tip to ensure uniform diameter of the whole cathetern• 10 cm marking along catheter body to confirm insertion depth.n• Balloon at distal tip with standard shape & volume. Kit must be with all accessories.n n 11 BERMAN CATHETER-n• Must be available in 4F, 5F, 6F and 7F sizesn• Should have 6-8 holes proximal to the balloon for dye injectionn• Catheter should be tapered at tip to ensure uniform diameter of the whole cathetern• 10 cm marking along catheter body to confirm insertion depth.n• balloon at distal tip with standard shape & volume. Kit must be with all accessories.nn 12 HIGH PRESSURE INJECTOR LINES n• 150 to 200 cm longn• Should be soft and kink resistantn• Should give reliable pressure measurementsn• Should be available in size of 150 to 200 cmn• Should have male luer lock connection at one end and a female luer lock connection at the other endn• Should meet highest medical standards for arterial pressure linesn 13 SYRINGE FOR PRESSURE INJECTOR INSTALLED IN RNT MEDICAL COLLEGE, UDAIPUR- (COMPANY – MEDRAD)n• Should be compatible with existing machines at RNTMCn• Should be of standard volume & materialn 14 Pressure Bag to be used in cath- lab to inject saline with high pressuren• transparent n• Non latex n• with stopcock well operationn• With visual analog dial showing pressures from 100 to 700 mmHgnn 15 INTRAVASCULAR RETRIEVER-SNAREn(‘AMPLATZ GOOSENESK’ TYPE)-nSnare kit should include with all accessories like sheath etc.n• A snare and its compatible sheathn• Should have nitinol shaft n• Should have 90 degree preformed snare loopn• Variable size of loop (5-35 mm)n 16 PTCA GUIDING CATHETER – n• Sizes of 5Fr., 6Fr., 7Fr. and 8Fr.n• All possible shapes of catheter should be available : Judkings/Femoral left and right, Extra back up support, Amplatz, Voda, Multipurpose, Hockey stick, trans-radial interventions, Bypass-graft/ LIMA interventions and othersn• Ultra thin high strength 2 X 2 flat wire mesh patternn• Hydrophilic coating n• Should also have availability of smaller length n catheters (90 cm) & regular length sizes. n• Should also have availability of catheters with side n holesn• Should also have short tip cathetersn 17 PTCA Guide wire- regular length, regular shaft support and floppy tip- n• 0.014” diametern• tip load 1 gmn• Directly jointed SUS and nitinol shaftn• DuoCore technology for superior torque transmissionn 18 PTCA Guide wire- regular length, regular shaft support and floppy tip- n• 0.014” diametern• tip load < 1 gmn• Directly jointed SUS and nitinol shaftn• DuoCore technology for superior torque transmissionn 19 PTCA Guide wire-regular length, extra support shaft and floppy tip- n• 0.014” diametern• tip load 1 gmn• Directly jointed SUS and nitinol shaftn• DuoCore technology for superior torque transmissionn 20 PTCA Guide wire-regular length, extra support shaft and floppy tip- n• 0.014” diametern• tip load < 1 gmn• Directly jointed SUS and nitinol shaftn• DuoCore technology for superior torque transmissionnnn 21 SPECIAL PTCA GUIDE WIRES WITH ELASTINITE CORE AND STAINLESS STEEL SHAFT SUPPORT n• Both regular and exchange length wiresn• Should have wires with varying degree of shaft n Support n tip load <1gmn 22 SPECIAL PTCA GUIDE WIRE WITH DUAL COATING nShould have distal hydrophilic coating and proximal hydrophobic coating.nShould have wires with variable tip stiffness and variable shaft support ntip load <1gmn 23 HEAVY DUTY NITINOL ALLOY EXTRA SUPPORT WIRE (REGULAR LENGTH AND EXCHANGE LENGTH)- n• 0.014 inches , Nitinol alloy , With angled tip -3-5 n cm longn• Tip with platinum/platinum alloy for optimum n visualizationn• With TFE coating , 180 cm to 300cmn 24 STEERABLE HIGH SUPPORT .014 INCH GUIDEWIRE (regular and exchange length)n• PTFE/ duraglide coated , n• Distal Radio-opaque tip 3 cm longn• Straight and J curve, 180 cm to 300 cm longn 25 PTCA WIRES WITH FACILITY OF BOOT LINKS FOR EXTENSION OF REGULAR WIRE - 26 EXTENSIION (DOC) WIRE FOR APPROVED REGULAR LENGTH PTCA GUIDE WIRES – 27 PENETRATION CATHETERS FOR CTO HAVING ROTATIONAL BLUNT PENETRATION – 28 Specialized PTCA Guide wire for retrograde approach & CTO –n0.014 One Piece core wire with jointless spring coil 22cm polymer sleeve length with slip coat coating over the polymer sleeve, tip load 1g and 0.8g,n180cm length, tip radiopacity 3cmn 29 Specialized PTCA Guide wire for CTO –stainless steel core without polymer cover with hydrophilic coating wire tip load varying from 1.7 to 8.7 gm. 30 Specialized PTCA Guide wire for CTO –stainless steel core with polymer cover with hydrophilic coating wire tip load varying from 0.8 to 4.8 gm. 31 Specialized PTCA Guide wire for retrograde approach & CTO –n0.014 One Piece core wire with jointless spring coil PTFE coating over the shaft ,tip load 3g,4.5g,6gand 12g, 180cm length with tip radiopacity 11cmn 32 Specialized PTCA Guide wire for retrograde approach & CTO –n0.014 One Piece core wire with jointless spring coil and slip coat on the spring coil , PTFE coating over the shaft ,tip load 3g, 180cm length with tip radiopacity 11cmn 33 Specialized PTCA Guide wire for retrograde approach & CTO –nNon hydrophilic coated tapered tip .009 with a tip load of 9gm and tip radiopacity of 20cmn 34 Specialized PTCA Guidewire for retrograde approach & – nDedicated guidewire for externalization with tip load of 3g, length 330cmn 35 Specialized PTCA Guide wire for retrograde approach & CTO –n One Piece core wire with jointless Spring coil with slip coat coating over the spring coil tapering to 0.009 l, tip load 9g ,180cm length, tip radiopacity 20cmn 36 Specialized PTCA Guide wire for retrograde approach & CTO –n0.014 One Piece core wire with jointless spring coil, PTFE coating over the shaft, tip load .7g, 180cm length with tip radiopacity 4cmn 37 Specialized PTCA Guide wire for retrograde approach & CTO –n0.014 One Piece core wire with jointless spring coil tapering to 0.009 16cm polymer sleeve length with slip coat coating over the polymer sleeve,190cm length tip radiopacity 16cmn 38 Specialized PTCA Guide wire for retrograde approach & CTO –nPTCA Guide Wire with SION TECH Technology -Tapered Type, Polymer sleeve, TipLoad 0.6-1.0gn 39 Specialized PTCA Guide wire for retrograde approach & CTO –n0.010 One Piece core wire with joint less Spring coil with SION TECH technology length 15cm , cone tip with a tip load of 1.7gm, 3.5gm and 4.5gm, 190cm length tip radiopacity 15cm, n 40 CORONARY TAPERED STENT n• DESn• Biodegradable polymer n• Ultra thin struts less than 80 micronn• Novel hybrid design-closed cells at ends and open cells in middlen 41 COBALT CHROMIUM CORONARY STENTS, PREMOUNTED ON BALLOON –(BMS) n• Available in all sizes and lengthsn 42 COVERED CORONARY STENTS –(Balloon Mounted) n• Available in all sizes and lengthsn 43 Balloon mounted sirolimus eluting stent with biodurable polymer on non stainless steel platform with uniform ultrathin struts (upto 60 microns), available in diameter from 2mm upto 4.5mm and varying lengths from 8mm to 48mm 44 Balloon mounted sirolimus eluting stent with biodurable polymer on non stainless steel platform with uniform thin struts (61-80 microns) including diameters from 2mm upto 4.5mm diamtert and varying lengths from 8mm to 48mm 45 Balloon mounted , polymer free, sirolimus eluting stent on non stainless steel platform with strut thickness (upto 60 micron) 46 Balloon mounted , polymer free, sirolimus eluting stent on non stainless steel platform with strut thickness (61-80 micron) 47 Balloon mounted sirolimus eluting stent on stainless steel platform with microporous surface biodegradable polymer and shellac resin top coat having diameter from 2 to 4.5 mm and length from 8 to 48 mm 48 Balloon mounted cobalt chromium, dual drug, polymer free stent with microporous surface and abluminal coating with shellac resin top coat. Probucol drug instead of polymer , available in diameter 2 to 4.5 mm and lengths 8 to 48 mm 49 Balloon mounted, Cobalt chromium, Abuminally coated sirolimus eluting stent with microporous surface and biodegradable polymer and shellac resin top coat having long lengths of 8mm to 48 mm and diameter 2 to 4.5 mm 50 Stainlees steel Balloon mounted, Abuminally coated sirolimus eluting stent with microporous surface and biodegradable polymer and shellac resign top coat having long lenghts of 8mm to 48 mm and diameter 2 to 4.5 mm with temperature controlled packing and temperature monitoring device 51 Sirolimus eluting stent having cobalt chromium platform with biodegradable polymer; abluminal and specialized gradient coating with strut thickness upto 60 microns n• Low profile balloon with entry profile 0.018”n• Advanced core wire technology in shaft for better push abilitynn 52 Sirolimus eluting stent having cobalt chromium platform with biodegradable polymer; abluminal and specialized gradient coating with strut thickness 61 -80 micronsn• Low profile balloon with entry profile 0.018”n• Advanced core wire technology in shaft for better push abilitynn 53 Balloon mounted Everolimus eluting stent with biodurable polymer on non-stainless steel platform. All sizes from 2.0 to 4.5 mm and length from 8 to 48 mm , Mid marker balloon placement at both ends with uniform strut thickness upto 60 microns 54 Balloon mounted Everolimus eluting stent with biodurable polymer on non-stainless steel platform. All sizes from 2.0 to 4.5 mm and length from 8 to 48 mm , Mid marker balloon placement at both ends with uniform strut thickness 61 to 80 microns 55 Ballooon mounted, Everolimus eluting stent with biodegradable polymer on non-stainless steel platform. All sizes from 2.0 to 4.5 mm and length from 8 to 48 mm(upto 60 microns) 56 Balloon mounted, Everolimus eluting stent with biodegradable polymer on non-stainless steel platform with uniform ultrathin struts (upto 61-80 microns)nAll sizes from 2.0 to 4.5 mm and length from 8 to 48 mmn 57 Balloon mounted, Zotarolimus eluting stent with biodurable polymer on non-stainless-steel platform for coronary artery diameters of all sizes including 2.0 mm and up to 4.5mm & Lengths from 8 to 48mm with uniform strut thickness upto 60 microns 58 Balloon mounted, Zotarolimus eluting stent with biodurable polymer on non-stainless-steel platform for coronary artery diameters of all sizes including 2.0 mm and up to 4.5mm & Lengths from 8 to 48mm with nuniform strut thickness from 61 to 80 micronsn 59 Balloon mounted drug eluting stents approved specifically for use with short duration (three month) DAPT (Dual ant platelet therapy). 60 PTCA Balloon (Semi compliant) with entry profile =0.016, Hydrophilic coating and tapered tip, available in diameter ranging from 1.00 to 4.00 mm and lengths 8 mm to 20 mm n• core wire shaft for better push ability 61 PTCA Balloon (Non compliant) with entry profile =0.016, Hydrophilic coating and tapered tip, available in diameter ranging from 2mm to 4.5 mm and lengths 5 mm to 20 mmnn• core wire shaft for better push ability 62 Intra vascular lithotripsy balloon (SHOCK WAVE) IVC catheter and connecting assembly, intergrated 12 mm SC balloon , 2 emitters (80 pulses per catheter) , Diameter from 2.5 to 4.0 mm 63 SPECIAL PTCA BALLOON CATHETER OF SIZES 0.9 TO 1.5 MM - n• Should be available in variable balloon lengths n 8-15mmnn 64 SPECIAL PTCA BALLOON - Ultra high pressure plaque modification device, dual layer/ RBP - 35 Bar and 45 bar/ Low crossing profile - Size :- 1.5 to 4.5 mm Dual markers 65 Special PTCA balloon catheter 0.85 mm Non compliant super high pressure balloon dilatation catheter pressure from 23 bar to 28 bar RBP variable large mono rail system, Hydrophilic coated. 66 SPECIAL OTW PTCA BALLOON FOR SEPTAL ABLATION FOR HOCM - 67 ZEROFOLD PTCA BALLOON - n• Available in all sizes and lengthn 68 CORONARY PTCA CUTTING BALLOON WITH FLEXTOMES - n• Available in all sizes and lengthsn 69 RAPID EXCHANGE LOW PRESSURE ATRAUMATIC MICROSPORES PTFE BALLOON CATHETER FOR LOCAL INFUSION OF DRUG, CATHETER LENGTH > 130 CM. SIZE 1.5 – 4.0 MM 70 SPECIAL PTCA BALLOON FOR CTO – n• Diameter should be 0.75 mm or lessn 71 DRUG ELUTING PTCA BALLOON - n• All types & sizesn• Different types of drugsn 72 SCORING BALLOON CATHETER FOR PTCAnAvailable in all sizes and lengthsn 73 Temporary bipolar pacing catheter- flow directedn• Latex balloon tipped, flow guided for stable insertionn• 10 cm depth markers to enhance placementn• Smooth, polyurethane hemocompatible coatingn• Clearly marked terminalsn• Shrouded 2 mm pin connector leadsn• Platinum electrodesn• Flexible tip design for delicate placement 74 PTMC BALLOON WITH HOLE IN Outer Balloon with side safety/micro holesnWith accessories-caliper, septal dilator, coiled wire, stylet for LV entry.n 75 PTMC BALLOON WITH HOLE IN Outer Balloon with side safety/micro holes without accessories 76 Brockenborough needle for trans septal puncture n(6 Fr/7Fr.)n 77 Mullin’s sheath-Kink resistent (7 Fr/ 8Fr ) for housing trans septal needle 78 Thrombus aspiration catheters (6 Fr) for manually aspirating Thrombus from coronary arteriesn• Inner diameter > 1.1 mmn• hydrophilic coating over the proximal part (minimum first 30 cm)n• With removable core wiren• Large and circular aspiration lumen 79 Guiding extention catheter (Guidezilla type)n• 120 proximal hypotube shaftn• 0.057 inner diameter & 0.066” outer diametern• Should be with marker and 1 X 1 bradingn 80 Double lumen micro catheter (crusade type) 81 Micro catheter to be used for CTO antegrade and retrograde apporch carvel type with entry profile 1.4 French 82 Coronary microcatheter with entry profile of 1.4 Fr. And crossing profile of 1.8 Fr. nAvailable length 135 cm and 150 cmn 83 Micro catheter to be used for CTO antegrade and retrogate apporch with proximal outer diameter 2.6French and distal outer diameter 1.8 French 84 Dedicated micro catheter for side branch access 85 IABP balloon catheter (standard sizes 30 cc and 40 cc)with accessories-n• Membrane length between 22 – 27.5 cmn• Inflated diameter 15 – 18 mmnn• Should be compatible with existing machine (data scope) in RNTMC, Udaipurn 86 Advance wound absorbent,haemostatic composed of 100% natural biopolymer Gamma sterilised and moisture proof packing pack size : 3.5x3.5 cm 87 Advance wound absorbent,haemostatic composed of 100% natural biopolymer Gamma sterilised and moisture proof packing pack Size : 5x5 cm 88 ARTERIAL PUNCTURE CLOSURE DEVICES – COLLAGEN PLUG BASED – 89 ARTERIAL PUNCTURE CLOSURE DEVICES – SUTURE BASED – 90 PTCA Inflation Device-n• Efficient locking system to maintain high pressuren• Rapid inflation and deflationn• Clear barrel for easy visualization of de-bubblingn• Luminescent analog pressure gauge (up to 30 atm)n• Ergomatric and use friendly hand held design 91 High Pressure PTCA inflation device analog pressure gauge upto 55 atm 92 Haemostatic Y-Connector for PTCA-Push-pull Mechanism-n• Should accommodate virtually all interventional devicesn• Luer connector at the guiding catheter endn• Rotating adapter at the guiding catheter endn• Should have bleed back safety mechanismn• Stepwise control for open, semi open and closed position.n

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 29-Jan-2021 CORRIGENDUM Date 11-Feb-2021
2 08-Feb-2021 CORRIGENDUM1 Technical Bid 11-Feb-2021

BOQ

Name of Work: Rate contract of Angiography / Angioplasty items
Sl.No.Item DescriptionItem noQuantityUnits
11ANGIOGRAPHY/ ANGIOPLASTY ITEMS
21.01FEMORAL INTRODUCER SHEATH WITH PUNCTURE NEEDLE FOR ADULTS (size 4 Fr. To 11Fr.) (standard Length)\n• Sizes 4 French/ 5 French/ 6 French/ 7 French/ 8 French/ 9 French/10 French/11French\n• 10-11 cm Long\n• Pack must include 18G, 6-7.5 cm long puncture needle and 0.035 inch guide wire \n• With haemostatic valve to prevent back leak and air aspiration\n• With suture eye for securing sheath\n• Kink resistant\n• With dilator-hub lock mechanism to prevent its back- out during insertion\n• With smooth and resistance free insertionitem11Nos
31.02Radial glide sheath INTRODUCER\nSHEATH with outer diameter one Fr size Under. (6 Fr sheath with outer diameter of 5 Fr)\n• Size 5 French/ 6 French/ 7 French\n• Sheath should be between 10-16 cm long\n• 0.021 and 0.025 inch guide wire compatible\n• Hydrophilic Coating\n• 20-22 G needle length 2’ inch\n• Guide Wire Should be available in 3 forms \n• A.) Plastic Short Angle\n\nB) Flex Straight \nC) Nitinol Floppy\n• With haemostatic valve to prevent back leak and air aspiration\n• With suture eye for securing sheath\n• Kink resistant\n• With dilator-hub lock mechanism to prevent its back-out during insertion\n• With smooth and resistance free insertion\nitem21Nos
41.03LONG INTRODUCER SHEATH (20-50 cm long) (size 4Fr. -11Fr.)\n• Size 4 French/ 5 French/ 6 French/ 7 French/ 8 French/ 9 French/ 10 French/ 11 French\n• Sheath should be between 20-50 cm long\n• 0.035 or 0.038 inch guide wire and compatibility \n• With haemostatic valve to prevent back leak and air aspiration\n• With suture eye for securing sheath\n• Kink resistant\n• With dilator-hub lock mechanism to prevent its back-out during insertion\n• With smooth and resistance free insertion\nitem31Nos
51.04TRANS RADIAL INTRODUCER SHEATHS 4F-7F-\n• Size 4 French/ 5 French/ 6 French/7 French\n• 07-10 cm long\n• Guide Wire Should be available in 2 forms \n• A.) Plastic Short Angle\nB) Flex Straight \n• Pack must include Surflash like puncture needle with plastic IV catheter, 20G – 22G, Length 2 inches \n• 0.025 inch Hydrophilic Miniplastic guide wire (Length 45 cm) and compatibility\n• With haemostatic valve to prevent back leak and air aspiration\n• With suture eye for securing sheath\n• Kink resistant\n• With Dilator hub-lock mechanism to prevent its back-out during insertion\n• With smooth and resistance free insertion\n \nitem41Nos
61.05LONG BRAIDED INTRODUCER SHEATH-\n• Size 6 French/ 7 French/ 8 French/ 9 French and above\n• Should be 30-90 cm and above\n• 0.021 or 0.025 inch guide wire compatible\n• With haemostatic valve to prevent back leak and air aspiration\n• With suture eye for securing sheath\n• Kink resistant\n\n• With dilator-hub lock mechanism to prevent its back-out during insertion\n\nitem51Nos
71.06FEMORAL INTRODUCER SHEATH WITH PUNCTURE NEEDLE FOR ADULTS (size 4 Fr. To 11Fr.) (standard Length)\n• Sizes 4 French/ 5 French/ 6 French/ 7 French/ 8 French/ 9 French/10 French/11French\n• 10-11 cm Long\n• Pack must include 18G, 6-7.5 cm long puncture needle and 0.035 inch guide wire \n• With haemostatic valve to prevent back leak and air aspiration\n• With suture eye for securing sheath\n• Kink resistant\n• With dilator-hub lock mechanism to prevent its back- out during insertion\n• With smooth and resistance free insertion\n• Integral side port with attached 3-way stopcock. The hub and sheath should be made of same material and there should be no joint between hub and sheath.\n\nitem61Nos
81.07TRANS RADIAL INTRODUCER SHEATHS 4F-7F-\n• Size 4 French/ 5 French/ 6 French/7 French\n• 07-10 cm long\n• Guide Wire Should be available in 2 forms \n• A.) Plastic Short Angle\nB) Flex Straight \n• Pack must include Surflash like puncture needle with plastic IV catheter, 20G – 22G, Length 2 inches \n• 0.025 inch Hydrophilic Miniplastic guide wire (Length 45 cm) and compatibility\n• With haemostatic valve to prevent back leak and air aspiration\n• With suture eye for securing sheath\n• Kink resistant\n• With Dilator hub-lock mechanism to prevent its back-out during insertion\n• With smooth and resistance free insertion\n• Integral side port with attached 3-way stopcock. The hub and sheath should be made of same material and there should be no joint between hub and sheath.\n\n \nitem71Nos
91.08TRANSRADIAL DIAGNOSTIC CORONARY CATHETER \n• 4 French/5 French/6French/ \n• diagnostic coronary catheters must be with various curves and shapes like ULTRA CURVE, IKARI CURVE, TRANSFORMER CURVE, TRACTIVE CURVE, and various shapes like tig II, jacky, sarah shapes etc. and length dedicated for trans radial coronary angiography and brachial approach also \n• Soft tip compression (GF) for atraumatic tip should be equal to or less then 100\n• Soft atraumatic, radiopaque tip with increased visibility\n• Double-braided stainless steel mesh middle layer for 1:1 torque control\n• kink resistance \n\n \nitem81Nos
101.09SPECIAL SWAN GANZ CATHETER WITH Safety Wedge:-\n• 4 F catheter should allow the passage of at least 0.021 inch, 5F-0.025 inch, 6 F-0.035 inch and 7 F, 8F-0.038 inch, PTFE/ hydrophilic guide wire\n• Must be available in 4F, 5F, 6F, and 7F and 8 Fr. Sizes\n• Catheter should be tapered at tip to ensure uniform diameter of the whole catheter\n• 10 cm marking along catheter body to confirm insertion depth.\n• Balloon at distal tip with standard shape & volume. Kit must be with all accessories.\n \nitem91Nos
111.1BERMAN CATHETER-\n• Must be available in 4F, 5F, 6F and 7F sizes\n• Should have 6-8 holes proximal to the balloon for dye injection\n• Catheter should be tapered at tip to ensure uniform diameter of the whole catheter\n• 10 cm marking along catheter body to confirm insertion depth.\n• balloon at distal tip with standard shape & volume. Kit must be with all accessories.\n\nitem101Nos
121.11HIGH PRESSURE INJECTOR LINES \n• 150 to 200 cm long\n• Should be soft and kink resistant\n• Should give reliable pressure measurements\n• Should be available in size of 150 to 200 cm\n• Should have male luer lock connection at one end and a female luer lock connection at the other end\n• Should meet highest medical standards for arterial pressure lines\nitem111Nos
131.12SYRINGE FOR PRESSURE INJECTOR INSTALLED IN RNT MEDICAL COLLEGE, UDAIPUR- (COMPANY – MEDRAD)\n• Should be compatible with existing machines at RNTMC\n• Should be of standard volume & material\nitem121Nos
141.13Pressure Bag to be used in cath- lab to inject saline with high pressure\n• transparent \n• Non latex \n• with stopcock well operation\n• With visual analog dial showing pressures from 100 to 700 mmHg\n\nitem131Nos
151.14INTRAVASCULAR RETRIEVER-SNARE\n(‘AMPLATZ GOOSENESK’ TYPE)-\nSnare kit should include with all accessories like sheath etc.\n• A snare and its compatible sheath\n• Should have nitinol shaft \n• Should have 90 degree preformed snare loop\n• Variable size of loop (5-35 mm)\nitem141Nos
161.15PTCA GUIDING CATHETER – \n• Sizes of 5Fr., 6Fr., 7Fr. and 8Fr.\n• All possible shapes of catheter should be available : Judkings/Femoral left and right, Extra back up support, Amplatz, Voda, Multipurpose, Hockey stick, trans-radial interventions, Bypass-graft/ LIMA interventions and others\n• Ultra thin high strength 2 X 2 flat wire mesh pattern\n• Hydrophilic coating \n• Should also have availability of smaller length \n catheters (90 cm) & regular length sizes. \n• Should also have availability of catheters with side \n holes\n• Should also have short tip catheters\nitem151Nos
171.16PTCA Guide wire- regular length, regular shaft support and floppy tip- \n• 0.014” diameter\n• tip load 1 gm\n• Directly jointed SUS and nitinol shaft\n• DuoCore technology for superior torque transmission\nitem161Nos
181.17PTCA Guide wire- regular length, regular shaft support and floppy tip- \n• 0.014” diameter\n• tip load < 1 gm\n• Directly jointed SUS and nitinol shaft\n• DuoCore technology for superior torque transmission\nitem171Nos
191.18PTCA Guide wire-regular length, extra support shaft and floppy tip- \n• 0.014” diameter\n• tip load 1 gm\n• Directly jointed SUS and nitinol shaft\n• DuoCore technology for superior torque transmission\nitem181Nos
201.19PTCA Guide wire-regular length, extra support shaft and floppy tip- \n• 0.014” diameter\n• tip load < 1 gm\n• Directly jointed SUS and nitinol shaft\n• DuoCore technology for superior torque transmission\n\n\nitem191Nos
211.2SPECIAL PTCA GUIDE WIRES WITH ELASTINITE CORE AND STAINLESS STEEL SHAFT SUPPORT \n• Both regular and exchange length wires\n• Should have wires with varying degree of shaft \n Support \n tip load <1gm\nitem201Nos
221.21SPECIAL PTCA GUIDE WIRE WITH DUAL COATING \nShould have distal hydrophilic coating and proximal hydrophobic coating.\nShould have wires with variable tip stiffness and variable shaft support \ntip load <1gm\nitem211Nos
231.22HEAVY DUTY NITINOL ALLOY EXTRA SUPPORT WIRE (REGULAR LENGTH AND EXCHANGE LENGTH)- \n• 0.014 inches , Nitinol alloy , With angled tip -3-5 \n cm long\n• Tip with platinum/platinum alloy for optimum \n visualization\n• With TFE coating , 180 cm to 300cm\nitem221Nos
241.23STEERABLE HIGH SUPPORT .014 INCH GUIDEWIRE (regular and exchange length)\n• PTFE/ duraglide coated , \n• Distal Radio-opaque tip 3 cm long\n• Straight and J curve, 180 cm to 300 cm long\nitem231Nos
251.24PTCA WIRES WITH FACILITY OF BOOT LINKS FOR EXTENSION OF REGULAR WIRE -item241Nos
261.25EXTENSIION (DOC) WIRE FOR APPROVED REGULAR LENGTH PTCA GUIDE WIRES –item251Nos
271.26PENETRATION CATHETERS FOR CTO HAVING ROTATIONAL BLUNT PENETRATION –item261Nos
281.27Specialized PTCA Guide wire for retrograde approach & CTO –\n0.014\" One Piece core wire with jointless spring coil 22cm polymer sleeve length with slip coat coating over the polymer sleeve, tip load 1g and 0.8g,\n180cm length, tip radiopacity 3cm\nitem271Nos
291.28Specialized PTCA Guide wire for CTO –stainless steel core without polymer cover with hydrophilic coating wire tip load varying from 1.7 to 8.7 gm.item281Nos
301.29Specialized PTCA Guide wire for CTO –stainless steel core with polymer cover with hydrophilic coating wire tip load varying from 0.8 to 4.8 gm.item291Nos
311.3Specialized PTCA Guide wire for retrograde approach & CTO –\n0.014\" One Piece core wire with jointless spring coil PTFE coating over the shaft ,tip load 3g,4.5g,6gand 12g, 180cm length with tip radiopacity 11cm\nitem301Nos
321.31Specialized PTCA Guide wire for retrograde approach & CTO –\n0.014\" One Piece core wire with jointless spring coil and slip coat on the spring coil , PTFE coating over the shaft ,tip load 3g, 180cm length with tip radiopacity 11cm\nitem311Nos
331.32Specialized PTCA Guide wire for retrograde approach & CTO –\nNon hydrophilic coated tapered tip .009\" with a tip load of 9gm and tip radiopacity of 20cm\nitem321Nos
341.33Specialized PTCA Guidewire for retrograde approach & – \nDedicated guidewire for externalization with tip load of 3g, length 330cm\nitem331Nos
351.34Specialized PTCA Guide wire for retrograde approach & CTO –\n One Piece core wire with jointless Spring coil with slip coat coating over the spring coil tapering to 0.009\" l, tip load 9g ,180cm length, tip radiopacity 20cm\nitem341Nos
361.35Specialized PTCA Guide wire for retrograde approach & CTO –\n0.014\" One Piece core wire with jointless spring coil, PTFE coating over the shaft, tip load .7g, 180cm length with tip radiopacity 4cm\nitem351Nos
371.36Specialized PTCA Guide wire for retrograde approach & CTO –\n0.014\" One Piece core wire with jointless spring coil tapering to 0.009\" 16cm polymer sleeve length with slip coat coating over the polymer sleeve,190cm length tip radiopacity 16cm\nitem361Nos
381.37Specialized PTCA Guide wire for retrograde approach & CTO –\nPTCA Guide Wire with SION TECH Technology -Tapered Type, Polymer sleeve, TipLoad 0.6-1.0g\nitem371Nos
391.38Specialized PTCA Guide wire for retrograde approach & CTO –\n0.010\" One Piece core wire with joint less Spring coil with SION TECH technology length 15cm , cone tip with a tip load of 1.7gm, 3.5gm and 4.5gm, 190cm length tip radiopacity 15cm, \nitem381Nos
401.39CORONARY TAPERED STENT \n• DES\n• Biodegradable polymer \n• Ultra thin struts less than 80 micron\n• Novel hybrid design-closed cells at ends and open cells in middle\nitem391Nos
411.4COBALT CHROMIUM CORONARY STENTS, PREMOUNTED ON BALLOON –(BMS) \n• Available in all sizes and lengths\nitem401Nos
421.41COVERED CORONARY STENTS –(Balloon Mounted) \n• Available in all sizes and lengths\nitem411Nos
431.42Balloon mounted sirolimus eluting stent with biodurable polymer on non stainless steel platform with uniform ultrathin struts (upto 60 microns), available in diameter from 2mm upto 4.5mm and varying lengths from 8mm to 48mmitem421Nos
441.43Balloon mounted sirolimus eluting stent with biodurable polymer on non stainless steel platform with uniform thin struts (61-80 microns) including diameters from 2mm upto 4.5mm diamtert and varying lengths from 8mm to 48mmitem431Nos
451.44Balloon mounted , polymer free, sirolimus eluting stent on non stainless steel platform with strut thickness (upto 60 micron)item441Nos
461.45Balloon mounted , polymer free, sirolimus eluting stent on non stainless steel platform with strut thickness (61-80 micron)item451Nos
471.46Balloon mounted sirolimus eluting stent on stainless steel platform with microporous surface biodegradable polymer and shellac resin top coat having diameter from 2 to 4.5 mm and length from 8 to 48 mmitem461Nos
481.47Balloon mounted cobalt chromium, dual drug, polymer free stent with microporous surface and abluminal coating with shellac resin top coat. Probucol drug instead of polymer , available in diameter 2 to 4.5 mm and lengths 8 to 48 mmitem471Nos
491.48Balloon mounted, Cobalt chromium, Abuminally coated sirolimus eluting stent with microporous surface and biodegradable polymer and shellac resin top coat having long lengths of 8mm to 48 mm and diameter 2 to 4.5 mmitem481Nos
501.49Stainlees steel Balloon mounted, Abuminally coated sirolimus eluting stent with microporous surface and biodegradable polymer and shellac resign top coat having long lenghts of 8mm to 48 mm and diameter 2 to 4.5 mm with temperature controlled packing and temperature monitoring deviceitem491Nos
511.5Sirolimus eluting stent having cobalt chromium platform with biodegradable polymer; abluminal and specialized gradient coating with strut thickness upto 60 microns \n• Low profile balloon with entry profile 0.018”\n• Advanced core wire technology in shaft for better push ability\n\nitem501Nos
521.51Sirolimus eluting stent having cobalt chromium platform with biodegradable polymer; abluminal and specialized gradient coating with strut thickness 61 -80 microns\n• Low profile balloon with entry profile 0.018”\n• Advanced core wire technology in shaft for better push ability\n\nitem511Nos
531.52Balloon mounted Everolimus eluting stent with biodurable polymer on non-stainless steel platform. All sizes from 2.0 to 4.5 mm and length from 8 to 48 mm , Mid marker balloon placement at both ends with uniform strut thickness upto 60 micronsitem521Nos
541.53Balloon mounted Everolimus eluting stent with biodurable polymer on non-stainless steel platform. All sizes from 2.0 to 4.5 mm and length from 8 to 48 mm , Mid marker balloon placement at both ends with uniform strut thickness 61 to 80 micronsitem531Nos
551.54Ballooon mounted, Everolimus eluting stent with biodegradable polymer on non-stainless steel platform. All sizes from 2.0 to 4.5 mm and length from 8 to 48 mm(upto 60 microns)item541Nos
561.55Balloon mounted, Everolimus eluting stent with biodegradable polymer on non-stainless steel platform with uniform ultrathin struts (upto 61-80 microns)\nAll sizes from 2.0 to 4.5 mm and length from 8 to 48 mm\nitem551Nos
571.56Balloon mounted, Zotarolimus eluting stent with biodurable polymer on non-stainless-steel platform for coronary artery diameters of all sizes including 2.0 mm and up to 4.5mm & Lengths from 8 to 48mm with uniform strut thickness upto 60 micronsitem561Nos
581.57Balloon mounted, Zotarolimus eluting stent with biodurable polymer on non-stainless-steel platform for coronary artery diameters of all sizes including 2.0 mm and up to 4.5mm & Lengths from 8 to 48mm with \nuniform strut thickness from 61 to 80 microns\nitem571Nos
591.58Balloon mounted drug eluting stents approved specifically for use with short duration (three month) DAPT (Dual ant platelet therapy).item581Nos
601.59PTCA Balloon (Semi compliant) with entry profile =0.016\", Hydrophilic coating and tapered tip, available in diameter ranging from 1.00 to 4.00 mm and lengths 8 mm to 20 mm \n• core wire shaft for better push abilityitem591Nos
611.6PTCA Balloon (Non compliant) with entry profile =0.016\", Hydrophilic coating and tapered tip, available in diameter ranging from 2mm to 4.5 mm and lengths 5 mm to 20 mm\n\n• core wire shaft for better push abilityitem601Nos
621.61Intra vascular lithotripsy balloon (SHOCK WAVE) IVC catheter and connecting assembly, intergrated 12 mm SC balloon , 2 emitters (80 pulses per catheter) , Diameter from 2.5 to 4.0 mmitem611Nos
631.62SPECIAL PTCA BALLOON CATHETER OF SIZES 0.9 TO 1.5 MM - \n• Should be available in variable balloon lengths \n 8-15mm\n\nitem621Nos
641.63SPECIAL PTCA BALLOON - Ultra high pressure plaque modification device, dual layer/ RBP - 35 Bar and 45 bar/ Low crossing profile - Size :- 1.5 to 4.5 mm Dual markersitem631Nos
651.64Special PTCA balloon catheter 0.85 mm Non compliant super high pressure balloon dilatation catheter pressure from 23 bar to 28 bar RBP variable large mono rail system, Hydrophilic coated.item641Nos
661.65SPECIAL OTW PTCA BALLOON FOR SEPTAL ABLATION FOR HOCM -item651Nos
671.66ZEROFOLD PTCA BALLOON - \n• Available in all sizes and length\nitem661Nos
681.67CORONARY PTCA CUTTING BALLOON WITH FLEXTOMES - \n• Available in all sizes and lengths\nitem671Nos
691.68RAPID EXCHANGE LOW PRESSURE ATRAUMATIC MICROSPORES PTFE BALLOON CATHETER FOR LOCAL INFUSION OF DRUG, CATHETER LENGTH > 130 CM. SIZE 1.5 – 4.0 MMitem681Nos
701.69SPECIAL PTCA BALLOON FOR CTO – \n• Diameter should be 0.75 mm or less\nitem691Nos
711.7DRUG ELUTING PTCA BALLOON - \n• All types & sizes\n• Different types of drugs\nitem701Nos
721.71SCORING BALLOON CATHETER FOR PTCA\nAvailable in all sizes and lengths\nitem711Nos
731.72Temporary bipolar pacing catheter- flow directed\n• Latex balloon tipped, flow guided for stable insertion\n• 10 cm depth markers to enhance placement\n• Smooth, polyurethane hemocompatible coating\n• Clearly marked terminals\n• Shrouded 2 mm pin connector leads\n• Platinum electrodes\n• Flexible tip design for delicate placementitem721Nos
741.73PTMC BALLOON WITH HOLE IN Outer Balloon with side safety/micro holes\nWith accessories-caliper, septal dilator, coiled wire, stylet for LV entry.\nitem731Nos
751.74PTMC BALLOON WITH HOLE IN Outer Balloon with side safety/micro holes without accessoriesitem741Nos
761.75Brockenborough needle for trans septal puncture \n(6 Fr/7Fr.)\nitem751Nos
771.76Mullin’s sheath-Kink resistent (7 Fr/ 8Fr ) for housing trans septal needleitem761Nos
781.77Thrombus aspiration catheters (6 Fr) for manually aspirating Thrombus from coronary arteries\n• Inner diameter > 1.1 mm\n• hydrophilic coating over the proximal part (minimum first 30 cm)\n• With removable core wire\n• Large and circular aspiration lumenitem771Nos
791.78Guiding extention catheter (Guidezilla type)\n• 120 proximal hypotube shaft\n• 0.057 inner diameter & 0.066” outer diameter\n• Should be with marker and 1 X 1 brading\nitem781Nos
801.79Double lumen micro catheter (crusade type)item791Nos
811.8Micro catheter to be used for CTO antegrade and retrograde apporch carvel type with entry profile 1.4 Frenchitem801Nos
821.81Coronary microcatheter with entry profile of 1.4 Fr. And crossing profile of 1.8 Fr. \nAvailable length 135 cm and 150 cm\nitem811Nos
831.82Micro catheter to be used for CTO antegrade and retrogate apporch with proximal outer diameter 2.6French and distal outer diameter 1.8 Frenchitem821Nos
841.83Dedicated micro catheter for side branch accessitem831Nos
851.84IABP balloon catheter (standard sizes 30 cc and 40 cc)with accessories-\n• Membrane length between 22 – 27.5 cm\n• Inflated diameter 15 – 18 mm\n\n• Should be compatible with existing machine (data scope) in RNTMC, Udaipur\nitem841Nos
861.85Advance wound absorbent,haemostatic composed of 100% natural biopolymer Gamma sterilised and moisture proof packing pack size : 3.5x3.5 cmitem851Nos
871.86Advance wound absorbent,haemostatic composed of 100% natural biopolymer Gamma sterilised and moisture proof packing pack Size : 5x5 cmitem861Nos
881.87ARTERIAL PUNCTURE CLOSURE DEVICES – COLLAGEN PLUG BASED –item871Nos
891.88ARTERIAL PUNCTURE CLOSURE DEVICES – SUTURE BASED –item881Nos
901.89PTCA Inflation Device-\n• Efficient locking system to maintain high pressure\n• Rapid inflation and deflation\n• Clear barrel for easy visualization of de-bubbling\n• Luminescent analog pressure gauge (up to 30 atm)\n• Ergomatric and use friendly hand held designitem891Nos
911.9High Pressure PTCA inflation device analog pressure gauge upto 55 atmitem901Nos
921.91Haemostatic Y-Connector for PTCA-Push-pull Mechanism-\n• Should accommodate virtually all interventional devices\n• Luer connector at the guiding catheter end\n• Rotating adapter at the guiding catheter end\n• Should have bleed back safety mechanism\n• Stepwise control for open, semi open and closed position.\nitem911Nos

AI Tender Summary

OUR REF NO 26568695
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 11-02-2021
Authority
Authority Name Medical College
Work Description Rate Contract Of Angiography And Angioplasty Items-1 ANGIOGRAPHY/ ANGIOPLASTY ITEMS 2 FEMORAL INTRODUCER SHEATH WITH PUNCTURE NEEDLE FOR ADULTS (size 4 Fr. To 11Fr.) (standard Length)n• Sizes 4 French/ 5 French/ 6 French/ 7 French/ 8 French/ 9 French/10 French/11Frenchn• 10-11 cm Longn• Pack must include 18G, 6-7.5 cm long puncture needle and 0.035 inch guide wire n• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantn• With dilator-hub lock mechanism to prevent its back- out during insertionn• With smooth and resistance free insertion 3 Radial glide sheath INTRODUCERnSHEATH with outer diameter one Fr size Under. (6 Fr sheath with outer diameter of 5 Fr)n• Size 5 French/ 6 French/ 7 Frenchn• Sheath should be between 10-16 cm longn• 0.021 and 0.025 inch guide wire compatiblen• Hydrophilic Coatingn• 20-22 G needle length 2’ inchn• Guide Wire Should be available in 3 forms n• A.) Plastic Short AnglennB) Flex Straight nC) Nitinol Floppyn• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantn• With dilator-hub lock mechanism to prevent its back-out during insertionn• With smooth and resistance free insertionn 4 LONG INTRODUCER SHEATH (20-50 cm long) (size 4Fr. -11Fr.)n• Size 4 French/ 5 French/ 6 French/ 7 French/ 8 French/ 9 French/ 10 French/ 11 Frenchn• Sheath should be between 20-50 cm longn• 0.035 or 0.038 inch guide wire and compatibility n• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantn• With dilator-hub lock mechanism to prevent its back-out during insertionn• With smooth and resistance free insertionn 5 TRANS RADIAL INTRODUCER SHEATHS 4F-7F-n• Size 4 French/ 5 French/ 6 French/7 Frenchn• 07-10 cm longn• Guide Wire Should be available in 2 forms n• A.) Plastic Short AnglenB) Flex Straight n• Pack must include Surflash like puncture needle with plastic IV catheter, 20G – 22G, Length 2 inches n• 0.025 inch Hydrophilic Miniplastic guide wire (Length 45 cm) and compatibilityn• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantn• With Dilator hub-lock mechanism to prevent its back-out during insertionn• With smooth and resistance free insertionn n 6 LONG BRAIDED INTRODUCER SHEATH-n• Size 6 French/ 7 French/ 8 French/ 9 French and aboven• Should be 30-90 cm and aboven• 0.021 or 0.025 inch guide wire compatiblen• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantnn• With dilator-hub lock mechanism to prevent its back-out during insertionnn 7 FEMORAL INTRODUCER SHEATH WITH PUNCTURE NEEDLE FOR ADULTS (size 4 Fr. To 11Fr.) (standard Length)n• Sizes 4 French/ 5 French/ 6 French/ 7 French/ 8 French/ 9 French/10 French/11Frenchn• 10-11 cm Longn• Pack must include 18G, 6-7.5 cm long puncture needle and 0.035 inch guide wire n• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantn• With dilator-hub lock mechanism to prevent its back- out during insertionn• With smooth and resistance free insertionn• Integral side port with attached 3-way stopcock. The hub and sheath should be made of same material and there should be no joint between hub and sheath.nn 8 TRANS RADIAL INTRODUCER SHEATHS 4F-7F-n• Size 4 French/ 5 French/ 6 French/7 Frenchn• 07-10 cm longn• Guide Wire Should be available in 2 forms n• A.) Plastic Short AnglenB) Flex Straight n• Pack must include Surflash like puncture needle with plastic IV catheter, 20G – 22G, Length 2 inches n• 0.025 inch Hydrophilic Miniplastic guide wire (Length 45 cm) and compatibilityn• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantn• With Dilator hub-lock mechanism to prevent its back-out during insertionn• With smooth and resistance free insertionn• Integral side port with attached 3-way stopcock. The hub and sheath should be made of same material and there should be no joint between hub and sheath.nn n 9 TRANSRADIAL DIAGNOSTIC CORONARY CATHETER n• 4 French/5 French/6French/ n• diagnostic coronary catheters must be with various curves and shapes like ULTRA CURVE, IKARI CURVE, TRANSFORMER CURVE, TRACTIVE CURVE, and various shapes like tig II, jacky, sarah shapes etc. and length dedicated for trans radial coronary angiography and brachial approach also n• Soft tip compression (GF) for atraumatic tip should be equal to or less then 100n• Soft atraumatic, radiopaque tip with increased visibilityn• Double-braided stainless steel mesh middle layer for 1:1 torque controln• kink resistance nn n 10 SPECIAL SWAN GANZ CATHETER WITH Safety Wedge:-n• 4 F catheter should allow the passage of at least 0.021 inch, 5F-0.025 inch, 6 F-0.035 inch and 7 F, 8F-0.038 inch, PTFE/ hydrophilic guide wiren• Must be available in 4F, 5F, 6F, and 7F and 8 Fr. Sizesn• Catheter should be tapered at tip to ensure uniform diameter of the whole cathetern• 10 cm marking along catheter body to confirm insertion depth.n• Balloon at distal tip with standard shape & volume. Kit must be with all accessories.n n 11 BERMAN CATHETER-n• Must be available in 4F, 5F, 6F and 7F sizesn• Should have 6-8 holes proximal to the balloon for dye injectionn• Catheter should be tapered at tip to ensure uniform diameter of the whole cathetern• 10 cm marking along catheter body to confirm insertion depth.n• balloon at distal tip with standard shape & volume. Kit must be with all accessories.nn 12 HIGH PRESSURE INJECTOR LINES n• 150 to 200 cm longn• Should be soft and kink resistantn• Should give reliable pressure measurementsn• Should be available in size of 150 to 200 cmn• Should have male luer lock connection at one end and a female luer lock connection at the other endn• Should meet highest medical standards for arterial pressure linesn 13 SYRINGE FOR PRESSURE INJECTOR INSTALLED IN RNT MEDICAL COLLEGE, UDAIPUR- (COMPANY – MEDRAD)n• Should be compatible with existing machines at RNTMCn• Should be of standard volume & materialn 14 Pressure Bag to be used in cath- lab to inject saline with high pressuren• transparent n• Non latex n• with stopcock well operationn• With visual analog dial showing pressures from 100 to 700 mmHgnn 15 INTRAVASCULAR RETRIEVER-SNAREn(‘AMPLATZ GOOSENESK’ TYPE)-nSnare kit should include with all accessories like sheath etc.n• A snare and its compatible sheathn• Should have nitinol shaft n• Should have 90 degree preformed snare loopn• Variable size of loop (5-35 mm)n 16 PTCA GUIDING CATHETER – n• Sizes of 5Fr., 6Fr., 7Fr. and 8Fr.n• All possible shapes of catheter should be available : Judkings/Femoral left and right, Extra back up support, Amplatz, Voda, Multipurpose, Hockey stick, trans-radial interventions, Bypass-graft/ LIMA interventions and othersn• Ultra thin high strength 2 X 2 flat wire mesh patternn• Hydrophilic coating n• Should also have availability of smaller length n catheters (90 cm) & regular length sizes. n• Should also have availability of catheters with side n holesn• Should also have short tip cathetersn 17 PTCA Guide wire- regular length, regular shaft support and floppy tip- n• 0.014” diametern• tip load 1 gmn• Directly jointed SUS and nitinol shaftn• DuoCore technology for superior torque transmissionn 18 PTCA Guide wire- regular length, regular shaft support and floppy tip- n• 0.014” diametern• tip load < 1 gmn• Directly jointed SUS and nitinol shaftn• DuoCore technology for superior torque transmissionn 19 PTCA Guide wire-regular length, extra support shaft and floppy tip- n• 0.014” diametern• tip load 1 gmn• Directly jointed SUS and nitinol shaftn• DuoCore technology for superior torque transmissionn 20 PTCA Guide wire-regular length, extra support shaft and floppy tip- n• 0.014” diametern• tip load < 1 gmn• Directly jointed SUS and nitinol shaftn• DuoCore technology for superior torque transmissionnnn 21 SPECIAL PTCA GUIDE WIRES WITH ELASTINITE CORE AND STAINLESS STEEL SHAFT SUPPORT n• Both regular and exchange length wiresn• Should have wires with varying degree of shaft n Support n tip load <1gmn 22 SPECIAL PTCA GUIDE WIRE WITH DUAL COATING nShould have distal hydrophilic coating and proximal hydrophobic coating.nShould have wires with variable tip stiffness and variable shaft support ntip load <1gmn 23 HEAVY DUTY NITINOL ALLOY EXTRA SUPPORT WIRE (REGULAR LENGTH AND EXCHANGE LENGTH)- n• 0.014 inches , Nitinol alloy , With angled tip -3-5 n cm longn• Tip with platinum/platinum alloy for optimum n visualizationn• With TFE coating , 180 cm to 300cmn 24 STEERABLE HIGH SUPPORT .014 INCH GUIDEWIRE (regular and exchange length)n• PTFE/ duraglide coated , n• Distal Radio-opaque tip 3 cm longn• Straight and J curve, 180 cm to 300 cm longn 25 PTCA WIRES WITH FACILITY OF BOOT LINKS FOR EXTENSION OF REGULAR WIRE - 26 EXTENSIION (DOC) WIRE FOR APPROVED REGULAR LENGTH PTCA GUIDE WIRES – 27 PENETRATION CATHETERS FOR CTO HAVING ROTATIONAL BLUNT PENETRATION – 28 Specialized PTCA Guide wire for retrograde approach & CTO –n0.014 One Piece core wire with jointless spring coil 22cm polymer sleeve length with slip coat coating over the polymer sleeve, tip load 1g and 0.8g,n180cm length, tip radiopacity 3cmn 29 Specialized PTCA Guide wire for CTO –stainless steel core without polymer cover with hydrophilic coating wire tip load varying from 1.7 to 8.7 gm. 30 Specialized PTCA Guide wire for CTO –stainless steel core with polymer cover with hydrophilic coating wire tip load varying from 0.8 to 4.8 gm. 31 Specialized PTCA Guide wire for retrograde approach & CTO –n0.014 One Piece core wire with jointless spring coil PTFE coating over the shaft ,tip load 3g,4.5g,6gand 12g, 180cm length with tip radiopacity 11cmn 32 Specialized PTCA Guide wire for retrograde approach & CTO –n0.014 One Piece core wire with jointless spring coil and slip coat on the spring coil , PTFE coating over the shaft ,tip load 3g, 180cm length with tip radiopacity 11cmn 33 Specialized PTCA Guide wire for retrograde approach & CTO –nNon hydrophilic coated tapered tip .009 with a tip load of 9gm and tip radiopacity of 20cmn 34 Specialized PTCA Guidewire for retrograde approach & – nDedicated guidewire for externalization with tip load of 3g, length 330cmn 35 Specialized PTCA Guide wire for retrograde approach & CTO –n One Piece core wire with jointless Spring coil with slip coat coating over the spring coil tapering to 0.009 l, tip load 9g ,180cm length, tip radiopacity 20cmn 36 Specialized PTCA Guide wire for retrograde approach & CTO –n0.014 One Piece core wire with jointless spring coil, PTFE coating over the shaft, tip load .7g, 180cm length with tip radiopacity 4cmn 37 Specialized PTCA Guide wire for retrograde approach & CTO –n0.014 One Piece core wire with jointless spring coil tapering to 0.009 16cm polymer sleeve length with slip coat coating over the polymer sleeve,190cm length tip radiopacity 16cmn 38 Specialized PTCA Guide wire for retrograde approach & CTO –nPTCA Guide Wire with SION TECH Technology -Tapered Type, Polymer sleeve, TipLoad 0.6-1.0gn 39 Specialized PTCA Guide wire for retrograde approach & CTO –n0.010 One Piece core wire with joint less Spring coil with SION TECH technology length 15cm , cone tip with a tip load of 1.7gm, 3.5gm and 4.5gm, 190cm length tip radiopacity 15cm, n 40 CORONARY TAPERED STENT n• DESn• Biodegradable polymer n• Ultra thin struts less than 80 micronn• Novel hybrid design-closed cells at ends and open cells in middlen 41 COBALT CHROMIUM CORONARY STENTS, PREMOUNTED ON BALLOON –(BMS) n• Available in all sizes and lengthsn 42 COVERED CORONARY STENTS –(Balloon Mounted) n• Available in all sizes and lengthsn 43 Balloon mounted sirolimus eluting stent with biodurable polymer on non stainless steel platform with uniform ultrathin struts (upto 60 microns), available in diameter from 2mm upto 4.5mm and varying lengths from 8mm to 48mm 44 Balloon mounted sirolimus eluting stent with biodurable polymer on non stainless steel platform with uniform thin struts (61-80 microns) including diameters from 2mm upto 4.5mm diamtert and varying lengths from 8mm to 48mm 45 Balloon mounted , polymer free, sirolimus eluting stent on non stainless steel platform with strut thickness (upto 60 micron) 46 Balloon mounted , polymer free, sirolimus eluting stent on non stainless steel platform with strut thickness (61-80 micron) 47 Balloon mounted sirolimus eluting stent on stainless steel platform with microporous surface biodegradable polymer and shellac resin top coat having diameter from 2 to 4.5 mm and length from 8 to 48 mm 48 Balloon mounted cobalt chromium, dual drug, polymer free stent with microporous surface and abluminal coating with shellac resin top coat. Probucol drug instead of polymer , available in diameter 2 to 4.5 mm and lengths 8 to 48 mm 49 Balloon mounted, Cobalt chromium, Abuminally coated sirolimus eluting stent with microporous surface and biodegradable polymer and shellac resin top coat having long lengths of 8mm to 48 mm and diameter 2 to 4.5 mm 50 Stainlees steel Balloon mounted, Abuminally coated sirolimus eluting stent with microporous surface and biodegradable polymer and shellac resign top coat having long lenghts of 8mm to 48 mm and diameter 2 to 4.5 mm with temperature controlled packing and temperature monitoring device 51 Sirolimus eluting stent having cobalt chromium platform with biodegradable polymer; abluminal and specialized gradient coating with strut thickness upto 60 microns n• Low profile balloon with entry profile 0.018”n• Advanced core wire technology in shaft for better push abilitynn 52 Sirolimus eluting stent having cobalt chromium platform with biodegradable polymer; abluminal and specialized gradient coating with strut thickness 61 -80 micronsn• Low profile balloon with entry profile 0.018”n• Advanced core wire technology in shaft for better push abilitynn 53 Balloon mounted Everolimus eluting stent with biodurable polymer on non-stainless steel platform. All sizes from 2.0 to 4.5 mm and length from 8 to 48 mm , Mid marker balloon placement at both ends with uniform strut thickness upto 60 microns 54 Balloon mounted Everolimus eluting stent with biodurable polymer on non-stainless steel platform. All sizes from 2.0 to 4.5 mm and length from 8 to 48 mm , Mid marker balloon placement at both ends with uniform strut thickness 61 to 80 microns 55 Ballooon mounted, Everolimus eluting stent with biodegradable polymer on non-stainless steel platform. All sizes from 2.0 to 4.5 mm and length from 8 to 48 mm(upto 60 microns) 56 Balloon mounted, Everolimus eluting stent with biodegradable polymer on non-stainless steel platform with uniform ultrathin struts (upto 61-80 microns)nAll sizes from 2.0 to 4.5 mm and length from 8 to 48 mmn 57 Balloon mounted, Zotarolimus eluting stent with biodurable polymer on non-stainless-steel platform for coronary artery diameters of all sizes including 2.0 mm and up to 4.5mm & Lengths from 8 to 48mm with uniform strut thickness upto 60 microns 58 Balloon mounted, Zotarolimus eluting stent with biodurable polymer on non-stainless-steel platform for coronary artery diameters of all sizes including 2.0 mm and up to 4.5mm & Lengths from 8 to 48mm with nuniform strut thickness from 61 to 80 micronsn 59 Balloon mounted drug eluting stents approved specifically for use with short duration (three month) DAPT (Dual ant platelet therapy). 60 PTCA Balloon (Semi compliant) with entry profile =0.016, Hydrophilic coating and tapered tip, available in diameter ranging from 1.00 to 4.00 mm and lengths 8 mm to 20 mm n• core wire shaft for better push ability 61 PTCA Balloon (Non compliant) with entry profile =0.016, Hydrophilic coating and tapered tip, available in diameter ranging from 2mm to 4.5 mm and lengths 5 mm to 20 mmnn• core wire shaft for better push ability 62 Intra vascular lithotripsy balloon (SHOCK WAVE) IVC catheter and connecting assembly, intergrated 12 mm SC balloon , 2 emitters (80 pulses per catheter) , Diameter from 2.5 to 4.0 mm 63 SPECIAL PTCA BALLOON CATHETER OF SIZES 0.9 TO 1.5 MM - n• Should be available in variable balloon lengths n 8-15mmnn 64 SPECIAL PTCA BALLOON - Ultra high pressure plaque modification device, dual layer/ RBP - 35 Bar and 45 bar/ Low crossing profile - Size :- 1.5 to 4.5 mm Dual markers 65 Special PTCA balloon catheter 0.85 mm Non compliant super high pressure balloon dilatation catheter pressure from 23 bar to 28 bar RBP variable large mono rail system, Hydrophilic coated. 66 SPECIAL OTW PTCA BALLOON FOR SEPTAL ABLATION FOR HOCM - 67 ZEROFOLD PTCA BALLOON - n• Available in all sizes and lengthn 68 CORONARY PTCA CUTTING BALLOON WITH FLEXTOMES - n• Available in all sizes and lengthsn 69 RAPID EXCHANGE LOW PRESSURE ATRAUMATIC MICROSPORES PTFE BALLOON CATHETER FOR LOCAL INFUSION OF DRUG, CATHETER LENGTH > 130 CM. SIZE 1.5 – 4.0 MM 70 SPECIAL PTCA BALLOON FOR CTO – n• Diameter should be 0.75 mm or lessn 71 DRUG ELUTING PTCA BALLOON - n• All types & sizesn• Different types of drugsn 72 SCORING BALLOON CATHETER FOR PTCAnAvailable in all sizes and lengthsn 73 Temporary bipolar pacing catheter- flow directedn• Latex balloon tipped, flow guided for stable insertionn• 10 cm depth markers to enhance placementn• Smooth, polyurethane hemocompatible coatingn• Clearly marked terminalsn• Shrouded 2 mm pin connector leadsn• Platinum electrodesn• Flexible tip design for delicate placement 74 PTMC BALLOON WITH HOLE IN Outer Balloon with side safety/micro holesnWith accessories-caliper, septal dilator, coiled wire, stylet for LV entry.n 75 PTMC BALLOON WITH HOLE IN Outer Balloon with side safety/micro holes without accessories 76 Brockenborough needle for trans septal puncture n(6 Fr/7Fr.)n 77 Mullin’s sheath-Kink resistent (7 Fr/ 8Fr ) for housing trans septal needle 78 Thrombus aspiration catheters (6 Fr) for manually aspirating Thrombus from coronary arteriesn• Inner diameter > 1.1 mmn• hydrophilic coating over the proximal part (minimum first 30 cm)n• With removable core wiren• Large and circular aspiration lumen 79 Guiding extention catheter (Guidezilla type)n• 120 proximal hypotube shaftn• 0.057 inner diameter & 0.066” outer diametern• Should be with marker and 1 X 1 bradingn 80 Double lumen micro catheter (crusade type) 81 Micro catheter to be used for CTO antegrade and retrograde apporch carvel type with entry profile 1.4 French 82 Coronary microcatheter with entry profile of 1.4 Fr. And crossing profile of 1.8 Fr. nAvailable length 135 cm and 150 cmn 83 Micro catheter to be used for CTO antegrade and retrogate apporch with proximal outer diameter 2.6French and distal outer diameter 1.8 French 84 Dedicated micro catheter for side branch access 85 IABP balloon catheter (standard sizes 30 cc and 40 cc)with accessories-n• Membrane length between 22 – 27.5 cmn• Inflated diameter 15 – 18 mmnn• Should be compatible with existing machine (data scope) in RNTMC, Udaipurn 86 Advance wound absorbent,haemostatic composed of 100% natural biopolymer Gamma sterilised and moisture proof packing pack size : 3.5x3.5 cm 87 Advance wound absorbent,haemostatic composed of 100% natural biopolymer Gamma sterilised and moisture proof packing pack Size : 5x5 cm 88 ARTERIAL PUNCTURE CLOSURE DEVICES – COLLAGEN PLUG BASED – 89 ARTERIAL PUNCTURE CLOSURE DEVICES – SUTURE BASED – 90 PTCA Inflation Device-n• Efficient locking system to maintain high pressuren• Rapid inflation and deflationn• Clear barrel for easy visualization of de-bubblingn• Luminescent analog pressure gauge (up to 30 atm)n• Ergomatric and use friendly hand held design 91 High Pressure PTCA inflation device analog pressure gauge upto 55 atm 92 Haemostatic Y-Connector for PTCA-Push-pull Mechanism-n• Should accommodate virtually all interventional devicesn• Luer connector at the guiding catheter endn• Rotating adapter at the guiding catheter endn• Should have bleed back safety mechanismn• Stepwise control for open, semi open and closed position.n
Basic Detail
Tender No 11/8-1-2021
Bidding Type Tender
Location
City MEMBER SECRETARY RMRS MBGH UDAIPUR
State Rajasthan
Key Dates
Publish Date 08 Feb 2021
Submission Date 11 Feb 2021
Open Date 12 Feb 2021
Finance
Tender Value Ref. Documents
Tender Fee 400
EMD Ref. Documents
Exemption Not Available
Document List
tenderangiocompress.pdf
2C1AA05B-8E11-469E-AC6B-6DDB70881C4E.html
BOQ_375236.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 08, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 11, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 11, 2021
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 11, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 12, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

tenderangiocompress.pdf

html

2C1AA05B-8E11-469E-AC6B-6DDB70881C4E.html

xls

BOQ_375236.xls

pdf

Tendernotice_1.pdf

Disclaimer