Tender Details

Rate Contract Of Angiography And Angioplasty Items-1 ANGIOGRAPHY/ ANGIOPLASTY ITEMS 2 FEMORAL INTRODUCER SHEATH WITH PUNCTURE NEEDLE FOR ADULTS (size 4 Fr. To 11Fr.) (standard Length)n• Sizes 4 French/ 5 French/ 6 French/ 7 French/ 8 French/ 9 French/10 French/11Frenchn• 10-11 cm Longn• Pack must include 18G, 6-7.5 cm long puncture needle and 0.035 inch guide wire n• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantn• With dilator-hub lock mechanism to prevent its back- out during insertionn• With smooth and resistance free insertion 3 Radial glide sheath INTRODUCERnSHEATH with outer diameter one Fr size Under. (6 Fr sheath with outer diameter of 5 Fr)n• Size 5 French/ 6 French/ 7 Frenchn• Sheath should be between 10-16 cm longn• 0.021 and 0.025 inch guide wire compatiblen• Hydrophilic Coatingn• 20-22 G needle length 2’ inchn• Guide Wire Should be available in 3 forms n• A.) Plastic Short AnglennB) Flex Straight nC) Nitinol Floppyn• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantn• With dilator-hub lock mechanism to prevent its back-out during insertionn• With smooth and resistance free insertionn 4 LONG INTRODUCER SHEATH (20-50 cm long) (size 4Fr. -11Fr.)n• Size 4 French/ 5 French/ 6 French/ 7 French/ 8 French/ 9 French/ 10 French/ 11 Frenchn• Sheath should be between 20-50 cm longn• 0.035 or 0.038 inch guide wire and compatibility n• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantn• With dilator-hub lock mechanism to prevent its back-out during insertionn• With smooth and resistance free insertionn 5 TRANS RADIAL INTRODUCER SHEATHS 4F-7F-n• Size 4 French/ 5 French/ 6 French/7 Frenchn• 07-10 cm longn• Guide Wire Should be available in 2 forms n• A.) Plastic Short AnglenB) Flex Straight n• Pack must include Surflash like puncture needle with plastic IV catheter, 20G – 22G, Length 2 inches n• 0.025 inch Hydrophilic Miniplastic guide wire (Length 45 cm) and compatibilityn• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantn• With Dilator hub-lock mechanism to prevent its back-out during insertionn• With smooth and resistance free insertionn n 6 LONG BRAIDED INTRODUCER SHEATH-n• Size 6 French/ 7 French/ 8 French/ 9 French and aboven• Should be 30-90 cm and aboven• 0.021 or 0.025 inch guide wire compatiblen• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantnn• With dilator-hub lock mechanism to prevent its back-out during insertionnn 7 FEMORAL INTRODUCER SHEATH WITH PUNCTURE NEEDLE FOR ADULTS (size 4 Fr. To 11Fr.) (standard Length)n• Sizes 4 French/ 5 French/ 6 French/ 7 French/ 8 French/ 9 French/10 French/11Frenchn• 10-11 cm Longn• Pack must include 18G, 6-7.5 cm long puncture needle and 0.035 inch guide wire n• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantn• With dilator-hub lock mechanism to prevent its back- out during insertionn• With smooth and resistance free insertionn• Integral side port with attached 3-way stopcock. The hub and sheath should be made of same material and there should be no joint between hub and sheath.nn 8 TRANS RADIAL INTRODUCER SHEATHS 4F-7F-n• Size 4 French/ 5 French/ 6 French/7 Frenchn• 07-10 cm longn• Guide Wire Should be available in 2 forms n• A.) Plastic Short AnglenB) Flex Straight n• Pack must include Surflash like puncture needle with plastic IV catheter, 20G – 22G, Length 2 inches n• 0.025 inch Hydrophilic Miniplastic guide wire (Length 45 cm) and compatibilityn• With haemostatic valve to prevent back leak and air aspirationn• With suture eye for securing sheathn• Kink resistantn• With Dilator hub-lock mechanism to prevent its back-out during insertionn• With smooth and resistance free insertionn• Integral side port with attached 3-way stopcock. The hub and sheath should be made of same material and there should be no joint between hub and sheath.nn n 9 TRANSRADIAL DIAGNOSTIC CORONARY CATHETER n• 4 French/5 French/6French/ n• diagnostic coronary catheters must be with various curves and shapes like ULTRA CURVE, IKARI CURVE, TRANSFORMER CURVE, TRACTIVE CURVE, and various shapes like tig II, jacky, sarah shapes etc. and length dedicated for trans radial coronary angiography and brachial approach also n• Soft tip compression (GF) for atraumatic tip should be equal to or less then 100n• Soft atraumatic, radiopaque tip with increased visibilityn• Double-braided stainless steel mesh middle layer for 1:1 torque controln• kink resistance nn n 10 SPECIAL SWAN GANZ CATHETER WITH Safety Wedge:-n• 4 F catheter should allow the passage of at least 0.021 inch, 5F-0.025 inch, 6 F-0.035 inch and 7 F, 8F-0.038 inch, PTFE/ hydrophilic guide wiren• Must be available in 4F, 5F, 6F, and 7F and 8 Fr. Sizesn• Catheter should be tapered at tip to ensure uniform diameter of the whole cathetern• 10 cm marking along catheter body to confirm insertion depth.n• Balloon at distal tip with standard shape & volume. Kit must be with all accessories.n n 11 BERMAN CATHETER-n• Must be available in 4F, 5F, 6F and 7F sizesn• Should have 6-8 holes proximal to the balloon for dye injectionn• Catheter should be tapered at tip to ensure uniform diameter of the whole cathetern• 10 cm marking along catheter body to confirm insertion depth.n• balloon at distal tip with standard shape & volume. Kit must be with all accessories.nn 12 HIGH PRESSURE INJECTOR LINES n• 150 to 200 cm longn• Should be soft and kink resistantn• Should give reliable pressure measurementsn• Should be available in size of 150 to 200 cmn• Should have male luer lock connection at one end and a female luer lock connection at the other endn• Should meet highest medical standards for arterial pressure linesn 13 SYRINGE FOR PRESSURE INJECTOR INSTALLED IN RNT MEDICAL COLLEGE, UDAIPUR- (COMPANY – MEDRAD)n• Should be compatible with existing machines at RNTMCn• Should be of standard volume & materialn 14 Pressure Bag to be used in cath- lab to inject saline with high pressuren• transparent n• Non latex n• with stopcock well operationn• With visual analog dial showing pressures from 100 to 700 mmHgnn 15 INTRAVASCULAR RETRIEVER-SNAREn(‘AMPLATZ GOOSENESK’ TYPE)-nSnare kit should include with all accessories like sheath etc.n• A snare and its compatible sheathn• Should have nitinol shaft n• Should have 90 degree preformed snare loopn• Variable size of loop (5-35 mm)n 16 PTCA GUIDING CATHETER – n• Sizes of 5Fr., 6Fr., 7Fr. and 8Fr.n• All possible shapes of catheter should be available : Judkings/Femoral left and right, Extra back up support, Amplatz, Voda, Multipurpose, Hockey stick, trans-radial interventions, Bypass-graft/ LIMA interventions and othersn• Ultra thin high strength 2 X 2 flat wire mesh patternn• Hydrophilic coating n• Should also have availability of smaller length n catheters (90 cm) & regular length sizes. n• Should also have availability of catheters with side n holesn• Should also have short tip cathetersn 17 PTCA Guide wire- regular length, regular shaft support and floppy tip- n• 0.014” diametern• tip load 1 gmn• Directly jointed SUS and nitinol shaftn• DuoCore technology for superior torque transmissionn 18 PTCA Guide wire- regular length, regular shaft support and floppy tip- n• 0.014” diametern• tip load < 1 gmn• Directly jointed SUS and nitinol shaftn• DuoCore technology for superior torque transmissionn 19 PTCA Guide wire-regular length, extra support shaft and floppy tip- n• 0.014” diametern• tip load 1 gmn• Directly jointed SUS and nitinol shaftn• DuoCore technology for superior torque transmissionn 20 PTCA Guide wire-regular length, extra support shaft and floppy tip- n• 0.014” diametern• tip load < 1 gmn• Directly jointed SUS and nitinol shaftn• DuoCore technology for superior torque transmissionnnn 21 SPECIAL PTCA GUIDE WIRES WITH ELASTINITE CORE AND STAINLESS STEEL SHAFT SUPPORT n• Both regular and exchange length wiresn• Should have wires with varying degree of shaft n Support n tip load <1gmn 22 SPECIAL PTCA GUIDE WIRE WITH DUAL COATING nShould have distal hydrophilic coating and proximal hydrophobic coating.nShould have wires with variable tip stiffness and variable shaft support ntip load <1gmn 23 HEAVY DUTY NITINOL ALLOY EXTRA SUPPORT WIRE (REGULAR LENGTH AND EXCHANGE LENGTH)- n• 0.014 inches , Nitinol alloy , With angled tip -3-5 n cm longn• Tip with platinum/platinum alloy for optimum n visualizationn• With TFE coating , 180 cm to 300cmn 24 STEERABLE HIGH SUPPORT .014 INCH GUIDEWIRE (regular and exchange length)n• PTFE/ duraglide coated , n• Distal Radio-opaque tip 3 cm longn• Straight and J curve, 180 cm to 300 cm longn 25 PTCA WIRES WITH FACILITY OF BOOT LINKS FOR EXTENSION OF REGULAR WIRE - 26 EXTENSIION (DOC) WIRE FOR APPROVED REGULAR LENGTH PTCA GUIDE WIRES – 27 PENETRATION CATHETERS FOR CTO HAVING ROTATIONAL BLUNT PENETRATION – 28 Specialized PTCA Guide wire for retrograde approach & CTO –n0.014 One Piece core wire with jointless spring coil 22cm polymer sleeve length with slip coat coating over the polymer sleeve, tip load 1g and 0.8g,n180cm length, tip radiopacity 3cmn 29 Specialized PTCA Guide wire for CTO –stainless steel core without polymer cover with hydrophilic coating wire tip load varying from 1.7 to 8.7 gm. 30 Specialized PTCA Guide wire for CTO –stainless steel core with polymer cover with hydrophilic coating wire tip load varying from 0.8 to 4.8 gm. 31 Specialized PTCA Guide wire for retrograde approach & CTO –n0.014 One Piece core wire with jointless spring coil PTFE coating over the shaft ,tip load 3g,4.5g,6gand 12g, 180cm length with tip radiopacity 11cmn 32 Specialized PTCA Guide wire for retrograde approach & CTO –n0.014 One Piece core wire with jointless spring coil and slip coat on the spring coil , PTFE coating over the shaft ,tip load 3g, 180cm length with tip radiopacity 11cmn 33 Specialized PTCA Guide wire for retrograde approach & CTO –nNon hydrophilic coated tapered tip .009 with a tip load of 9gm and tip radiopacity of 20cmn 34 Specialized PTCA Guidewire for retrograde approach & – nDedicated guidewire for externalization with tip load of 3g, length 330cmn 35 Specialized PTCA Guide wire for retrograde approach & CTO –n One Piece core wire with jointless Spring coil with slip coat coating over the spring coil tapering to 0.009 l, tip load 9g ,180cm length, tip radiopacity 20cmn 36 Specialized PTCA Guide wire for retrograde approach & CTO –n0.014 One Piece core wire with jointless spring coil, PTFE coating over the shaft, tip load .7g, 180cm length with tip radiopacity 4cmn 37 Specialized PTCA Guide wire for retrograde approach & CTO –n0.014 One Piece core wire with jointless spring coil tapering to 0.009 16cm polymer sleeve length with slip coat coating over the polymer sleeve,190cm length tip radiopacity 16cmn 38 Specialized PTCA Guide wire for retrograde approach & CTO –nPTCA Guide Wire with SION TECH Technology -Tapered Type, Polymer sleeve, TipLoad 0.6-1.0gn 39 Specialized PTCA Guide wire for retrograde approach & CTO –n0.010 One Piece core wire with joint less Spring coil with SION TECH technology length 15cm , cone tip with a tip load of 1.7gm, 3.5gm and 4.5gm, 190cm length tip radiopacity 15cm, n 40 CORONARY TAPERED STENT n• DESn• Biodegradable polymer n• Ultra thin struts less than 80 micronn• Novel hybrid design-closed cells at ends and open cells in middlen 41 COBALT CHROMIUM CORONARY STENTS, PREMOUNTED ON BALLOON –(BMS) n• Available in all sizes and lengthsn 42 COVERED CORONARY STENTS –(Balloon Mounted) n• Available in all sizes and lengthsn 43 Balloon mounted sirolimus eluting stent with biodurable polymer on non stainless steel platform with uniform ultrathin struts (upto 60 microns), available in diameter from 2mm upto 4.5mm and varying lengths from 8mm to 48mm 44 Balloon mounted sirolimus eluting stent with biodurable polymer on non stainless steel platform with uniform thin struts (61-80 microns) including diameters from 2mm upto 4.5mm diamtert and varying lengths from 8mm to 48mm 45 Balloon mounted , polymer free, sirolimus eluting stent on non stainless steel platform with strut thickness (upto 60 micron) 46 Balloon mounted , polymer free, sirolimus eluting stent on non stainless steel platform with strut thickness (61-80 micron) 47 Balloon mounted sirolimus eluting stent on stainless steel platform with microporous surface biodegradable polymer and shellac resin top coat having diameter from 2 to 4.5 mm and length from 8 to 48 mm 48 Balloon mounted cobalt chromium, dual drug, polymer free stent with microporous surface and abluminal coating with shellac resin top coat. Probucol drug instead of polymer , available in diameter 2 to 4.5 mm and lengths 8 to 48 mm 49 Balloon mounted, Cobalt chromium, Abuminally coated sirolimus eluting stent with microporous surface and biodegradable polymer and shellac resin top coat having long lengths of 8mm to 48 mm and diameter 2 to 4.5 mm 50 Stainlees steel Balloon mounted, Abuminally coated sirolimus eluting stent with microporous surface and biodegradable polymer and shellac resign top coat having long lenghts of 8mm to 48 mm and diameter 2 to 4.5 mm with temperature controlled packing and temperature monitoring device 51 Sirolimus eluting stent having cobalt chromium platform with biodegradable polymer; abluminal and specialized gradient coating with strut thickness upto 60 microns n• Low profile balloon with entry profile 0.018”n• Advanced core wire technology in shaft for better push abilitynn 52 Sirolimus eluting stent having cobalt chromium platform with biodegradable polymer; abluminal and specialized gradient coating with strut thickness 61 -80 micronsn• Low profile balloon with entry profile 0.018”n• Advanced core wire technology in shaft for better push abilitynn 53 Balloon mounted Everolimus eluting stent with biodurable polymer on non-stainless steel platform. All sizes from 2.0 to 4.5 mm and length from 8 to 48 mm , Mid marker balloon placement at both ends with uniform strut thickness upto 60 microns 54 Balloon mounted Everolimus eluting stent with biodurable polymer on non-stainless steel platform. All sizes from 2.0 to 4.5 mm and length from 8 to 48 mm , Mid marker balloon placement at both ends with uniform strut thickness 61 to 80 microns 55 Ballooon mounted, Everolimus eluting stent with biodegradable polymer on non-stainless steel platform. All sizes from 2.0 to 4.5 mm and length from 8 to 48 mm(upto 60 microns) 56 Balloon mounted, Everolimus eluting stent with biodegradable polymer on non-stainless steel platform with uniform ultrathin struts (upto 61-80 microns)nAll sizes from 2.0 to 4.5 mm and length from 8 to 48 mmn 57 Balloon mounted, Zotarolimus eluting stent with biodurable polymer on non-stainless-steel platform for coronary artery diameters of all sizes including 2.0 mm and up to 4.5mm & Lengths from 8 to 48mm with uniform strut thickness upto 60 microns 58 Balloon mounted, Zotarolimus eluting stent with biodurable polymer on non-stainless-steel platform for coronary artery diameters of all sizes including 2.0 mm and up to 4.5mm & Lengths from 8 to 48mm with nuniform strut thickness from 61 to 80 micronsn 59 Balloon mounted drug eluting stents approved specifically for use with short duration (three month) DAPT (Dual ant platelet therapy). 60 PTCA Balloon (Semi compliant) with entry profile =0.016, Hydrophilic coating and tapered tip, available in diameter ranging from 1.00 to 4.00 mm and lengths 8 mm to 20 mm n• core wire shaft for better push ability 61 PTCA Balloon (Non compliant) with entry profile =0.016, Hydrophilic coating and tapered tip, available in diameter ranging from 2mm to 4.5 mm and lengths 5 mm to 20 mmnn• core wire shaft for better push ability 62 Intra vascular lithotripsy balloon (SHOCK WAVE) IVC catheter and connecting assembly, intergrated 12 mm SC balloon , 2 emitters (80 pulses per catheter) , Diameter from 2.5 to 4.0 mm 63 SPECIAL PTCA BALLOON CATHETER OF SIZES 0.9 TO 1.5 MM - n• Should be available in variable balloon lengths n 8-15mmnn 64 SPECIAL PTCA BALLOON - Ultra high pressure plaque modification device, dual layer/ RBP - 35 Bar and 45 bar/ Low crossing profile - Size :- 1.5 to 4.5 mm Dual markers 65 Special PTCA balloon catheter 0.85 mm Non compliant super high pressure balloon dilatation catheter pressure from 23 bar to 28 bar RBP variable large mono rail system, Hydrophilic coated. 66 SPECIAL OTW PTCA BALLOON FOR SEPTAL ABLATION FOR HOCM - 67 ZEROFOLD PTCA BALLOON - n• Available in all sizes and lengthn 68 CORONARY PTCA CUTTING BALLOON WITH FLEXTOMES - n• Available in all sizes and lengthsn 69 RAPID EXCHANGE LOW PRESSURE ATRAUMATIC MICROSPORES PTFE BALLOON CATHETER FOR LOCAL INFUSION OF DRUG, CATHETER LENGTH > 130 CM. SIZE 1.5 – 4.0 MM 70 SPECIAL PTCA BALLOON FOR CTO – n• Diameter should be 0.75 mm or lessn 71 DRUG ELUTING PTCA BALLOON - n• All types & sizesn• Different types of drugsn 72 SCORING BALLOON CATHETER FOR PTCAnAvailable in all sizes and lengthsn 73 Temporary bipolar pacing catheter- flow directedn• Latex balloon tipped, flow guided for stable insertionn• 10 cm depth markers to enhance placementn• Smooth, polyurethane hemocompatible coatingn• Clearly marked terminalsn• Shrouded 2 mm pin connector leadsn• Platinum electrodesn• Flexible tip design for delicate placement 74 PTMC BALLOON WITH HOLE IN Outer Balloon with side safety/micro holesnWith accessories-caliper, septal dilator, coiled wire, stylet for LV entry.n 75 PTMC BALLOON WITH HOLE IN Outer Balloon with side safety/micro holes without accessories 76 Brockenborough needle for trans septal puncture n(6 Fr/7Fr.)n 77 Mullin’s sheath-Kink resistent (7 Fr/ 8Fr ) for housing trans septal needle 78 Thrombus aspiration catheters (6 Fr) for manually aspirating Thrombus from coronary arteriesn• Inner diameter > 1.1 mmn• hydrophilic coating over the proximal part (minimum first 30 cm)n• With removable core wiren• Large and circular aspiration lumen 79 Guiding extention catheter (Guidezilla type)n• 120 proximal hypotube shaftn• 0.057 inner diameter & 0.066” outer diametern• Should be with marker and 1 X 1 bradingn 80 Double lumen micro catheter (crusade type) 81 Micro catheter to be used for CTO antegrade and retrograde apporch carvel type with entry profile 1.4 French 82 Coronary microcatheter with entry profile of 1.4 Fr. And crossing profile of 1.8 Fr. nAvailable length 135 cm and 150 cmn 83 Micro catheter to be used for CTO antegrade and retrogate apporch with proximal outer diameter 2.6French and distal outer diameter 1.8 French 84 Dedicated micro catheter for side branch access 85 IABP balloon catheter (standard sizes 30 cc and 40 cc)with accessories-n• Membrane length between 22 – 27.5 cmn• Inflated diameter 15 – 18 mmnn• Should be compatible with existing machine (data scope) in RNTMC, Udaipurn 86 Advance wound absorbent,haemostatic composed of 100% natural biopolymer Gamma sterilised and moisture proof packing pack size : 3.5x3.5 cm 87 Advance wound absorbent,haemostatic composed of 100% natural biopolymer Gamma sterilised and moisture proof packing pack Size : 5x5 cm 88 ARTERIAL PUNCTURE CLOSURE DEVICES – COLLAGEN PLUG BASED – 89 ARTERIAL PUNCTURE CLOSURE DEVICES – SUTURE BASED – 90 PTCA Inflation Device-n• Efficient locking system to maintain high pressuren• Rapid inflation and deflationn• Clear barrel for easy visualization of de-bubblingn• Luminescent analog pressure gauge (up to 30 atm)n• Ergomatric and use friendly hand held design 91 High Pressure PTCA inflation device analog pressure gauge upto 55 atm 92 Haemostatic Y-Connector for PTCA-Push-pull Mechanism-n• Should accommodate virtually all interventional devicesn• Luer connector at the guiding catheter endn• Rotating adapter at the guiding catheter endn• Should have bleed back safety mechanismn• Stepwise control for open, semi open and closed position.n

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Jan-2021 CORRIGENDUM Date 11-02-2021
2 08-Feb-2021 CORRIGENDUM1 Technical Bid 11-02-2021

Key Value

Document Fees
INR 400 /-
EMD
Refer document
Tender Value
Refer document