Renovation Work Of Kscdc Building At Elathur Kozhikode
Tender Value
Ref. Documents
Estimated cost
Bid Submission
19 Jan 2021
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
elathur kozhikode → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Renovation Work Of Kscdc Building At Elathur Kozhikode
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-Jan-2021 | date extension | Date | 19-Jan-2021 |
BOQ
| Name of Work: Renovation work of KSCDC building at Elathur- Kozhikode | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Particulars | 1 | ||
| 2 | 1.01 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. In cement mortar | 1.01 | 0.742 | m3 |
| 3 | 1.02 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): From brick work in cement mortar | 1.02 | 52.84 | Nos |
| 4 | 1.03 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar | 1.03 | 4.778 | m3 |
| 5 | 1.04 | Removing mortar from and cleaning stones and concrete articles (net quantity of stacks of cleaned materials will be measured): | 1.04 | 4.78 | m3 |
| 6 | 1.05 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. Quantity | 1.05 | 2 | m2 |
| 7 | 1.06 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. | 1.06 | 5.7 | m3 |
| 8 | 1.07 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : Of sectional area 40 square centimetres and above. | 1.07 | 0.361 | m3 |
| 9 | 1.08 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: Of area 3 sq. metres and below | 1.08 | 8 | Each |
| 10 | 1.09 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: Of area beyond 3 sq. metres | 1.09 | 2 | Each |
| 11 | 1.1 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete | 1.1 | 576.818 | m2 |
| 12 | 1.11 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. | 1.11 | 951.62 | m2 |
| 13 | 1.12 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift upto1.5 m. All kinds of soil. | 1.12 | 122.709 | m2 |
| 14 | 1.13 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. | 1.13 | 37.45 | m3 |
| 15 | 1.14 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand(zone-III) : 8 graded stone aggregate 40 mm nominal size). | 1.14 | 11.143 | m3 |
| 16 | 1.15 | DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at siteQuantity | 1.15 | 23.675 | m3 |
| 17 | 1.16 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand). | 1.16 | 14.173 | m3 |
| 18 | 1.17 | Centering and shuttering including strutting, propping etc. and removal of form for all heights: Foundations, footings, bases of columns, etc. for mass concrete. | 1.17 | 2.461 | m2 |
| 19 | 1.18 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but , excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works up to plinth level. | 1.18 | 0.246 | m3 |
| 20 | 1.19 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but , excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works above plinth level up to floor V level. | 1.19 | 7.894 | m3 |
| 21 | 1.2 | Centering and shuttering including strutting, propping etc. and removal of form for all heights: Lintels, beams, plinth beams, girders, bressumers and cantilevers. | 1.2 | 75.62 | m2 |
| 22 | 1.21 | Centering and shuttering including strutting, propping etc. and removal of form for all heights: Weather shade, Chajjas, corbels etc., including edges. | 1.21 | 25.634 | m2 |
| 23 | 1.22 | Centering and shuttering including strutting, propping etc. and removal of form for all heights:Suspended floors, roofs, landings, balconies and access platform. | 1.22 | 4.85 | m2 |
| 24 | 1.23 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more. | 1.23 | 563.4 | kg |
| 25 | 1.24 | Add for using extra cement in the items of design mix over and above the specified cement content therein. | 1.24 | 3.155 | Quintal |
| 26 | 1.25 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | 1.25 | 26.215 | m3 |
| 27 | 1.26 | Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge | 1.26 | 14.905 | m3 |
| 28 | 1.27 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(Zone III) : 4 graded stone aggregate 20mm nominal size). | 1.27 | 62.465 | m2 |
| 29 | 1.28 | Applying antitermite treatment on flooring using second generation chemicals which is eco freiendly and nil harmful for human beings and pet animals which control the pests including all cost and labor charges etc complete | 1.28 | 98.824 | m2 |
| 30 | 1.29 | Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc. | 1.29 | 0.593 | m3 |
| 31 | 1.3 | Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. | 1.3 | 22.201 | m3 |
| 32 | 1.31 | Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete | 1.31 | 19.037 | m3 |
| 33 | 1.32 | Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at window sills, ceiling level and the like. Cement mortar 1:6 (1 cement : 6 coarse sand). | 1.32 | 4.773 | m3 |
| 34 | 1.33 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. | 1.33 | 337.442 | kg |
| 35 | 1.34 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces. | 1.34 | 15.57 | m2 |
| 36 | 1.35 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) | 1.35 | 112.93 | kg |
| 37 | 1.36 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) | 1.36 | 147.257 | kg |
| 38 | 1.37 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness | 1.37 | 29.264 | m2 |
| 39 | 1.38 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides. | 1.38 | 12.39 | m2 |
| 40 | 1.39 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (Brand access- having brand logo with ISI, IS:3564, embossed on the body, door weight upto 80kg and door width upto 150mm), with necessary accessories and screws etc. complete | 1.39 | 8 | Nos |
| 41 | 1.4 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer-in-Charge. | 1.4 | 34.8 | m |
| 42 | 1.41 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing. 30 mm thick plain PVC door shutters. | 1.41 | 10.081 | m2 |
| 43 | 1.42 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40mm dia. M.S. tube 1.5m centre to centre horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. | 1.42 | 248.196 | m2 |
| 44 | 1.43 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) | 1.43 | 635.183 | m2 |
| 45 | 1.44 | 20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) | 1.44 | 264.036 | m2 |
| 46 | 1.45 | 9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete | 1.45 | 47.606 | m2 |
| 47 | 1.46 | Applying nitozinc primer for exposed reinforcement, applying Nito bond SBR bonding agent on concrete surface and plaster using polymer modified mortar- Rendroc Hb2(a+b), for 15mm thick including cost and conveyance of all materials, labour charges etc complete. | 1.46 | 2 | m2 |
| 48 | 1.47 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm | 1.47 | 259.151 | m2 |
| 49 | 1.48 | Modified Item Code 11.41.2 : Providing and laying Antiskid vitrified floor tiles (Kajaria) in different sizesFloor-Kitchen and passage\n(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to\nIS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1\ncement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc.,\ncomplete. Size of Tile 600 x 600 mm. | 1.48 | 27.6 | m2 |
| 50 | 1.49 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete. | 1.49 | 17.21 | m2 |
| 51 | 1.5 | Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness. | 1.5 | 185.59 | m2 |
| 52 | 1.51 | Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3kg/sqm Vitrified tile quantity | 1.51 | 1 | m2 |
| 53 | 1.52 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), including grouting the joint with white cement &matching pigments etc. complete. Size of Tile 600x600 mm | 1.52 | 205.475 | m2 |
| 54 | 1.53 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), including grouting the joint with white cement &matching pigments etc. complete. Size of Tile 600x600 mm | 1.53 | 18.9 | m2 |
| 55 | 1.54 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. | 1.54 | 37.416 | m2 |
| 56 | 1.55 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm. | 1.55 | 9.075 | m2 |
| 57 | 1.56 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete | 1.56 | 76.147 | m2 |
| 58 | 1.57 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer. | 1.57 | 682.22 | m2 |
| 59 | 1.58 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | 1.58 | 938.317 | m2 |
| 60 | 1.59 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work. | 1.59 | 938.38 | m2 |
| 61 | 1.6 | Applying single coat of clear coat and primer on wall plastering surface and including all cost and conveyance of all materials and labour charges etc. complete | 1.6 | 263.85 | m2 |
| 62 | 1.61 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. | 1.61 | 51.129 | m2 |
| 63 | 1.62 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. | 1.62 | 17.151 | m |
| 64 | 1.63 | Providing water cutting to bottom edge side od slab/ sunshade by 25mm wide and 15mm thick in cement mortar 1:3 including cost and conveyance of all materials, labour charges etc. | 1.63 | 36.62 | m |
| 65 | 1.64 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the\nentire treated surface will be measured) | 1.64 | 80.325 | m2 |
| 66 | 1.65 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work upto plinth level (cement concrete 1:2:4) 1 cement: 2 coarse sand: 4 graded stone aggregate 6mm nominal size. | 1.65 | 6.025 | m3 |
| 67 | 1.66 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | 1.66 | 5000 | litre |
| 68 | 2 | 1 Appendix A- Interior works | 2 | ||
| 69 | 2.01 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. | 2.01 | 121.514 | m2 |
| 70 | 2.02 | Providing and fixing false ceiling with 7.5mm thick PVC plain panel board ceiling of approved quality in aluminium frame work with necessory screws etc. complete | 2.02 | 210.266 | m2 |
| 71 | 2.03 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). | 2.03 | 189.244 | kg |
| 72 | 2.04 | Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI metal ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.50 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm ( both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. | 2.04 | 21.6 | m2 |
| 73 | 2.05 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the rate of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm or both sides of joint and two coats of primer suitable for board, all as per manufacture's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board. | 2.05 | 6 | m2 |
| 74 | 2.06 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer. | 2.06 | 6 | m2 |
| 75 | 2.07 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | 2.07 | 12 | m2 |
| 76 | 2.08 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work. | 2.08 | 6 | m2 |
| 77 | 2.09 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) | 2.09 | 22.106 | kg |
| 78 | 2.1 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) | 2.1 | 8.7 | kg |
| 79 | 2.11 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). | 2.11 | 4.066 | m2 |
| 80 | 2.12 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness | 2.12 | 4.066 | m2 |
| 81 | 2.13 | Providing and fixing aluminium hanging floor door stopper, with necessary screws etc. complete as per the direction of engineer-in- cgarge | 2.13 | 2 | Nos |
| 82 | 2.14 | Providing and fixing American handles for aluminium door including necessary cutting and making good etc. complete | 2.14 | 2 | Nos |
| 83 | 2.15 | Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. | 2.15 | 1 | Each |
| 84 | 2.16 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x10 mm | 2.16 | 4 | Each |
| 85 | 2.17 | Providing and fixing hydraulic door closer (make: Hafele/ Equivalent, DC 602 Door Closer, hold open arm size 2/3, wt 45-60 kg), with double speed adjustment with necessary accessories and screws ets, complete | 2.17 | 2 | Nos |
| 86 | 3 | 2 Appendix B- Furniture works | 3 | ||
| 87 | 3.01 | Storage: Providing and fixing storage as per architect approved drawing (wide 50cm). Frame work to be finished with 19mm thick plywood (IS:710 Grade BWP, Prestige/Equivalent). Outer and inner portion of the storage to be finished with 1mm laminate(Century/Equivalent), s per drawing. Use necessory SS hinges, SS handles, Locks etc (make: Hettich/Ebco). Finish as per drawing with neccessory grooves, projections and electrical openings if any. Including cost of conveyance of all materials labour charges etc. | 3.01 | 21.345 | m2 |
| 88 | 3.02 | Overhead storage with laminate finish: Providing and fixing overhead storage as per architect approved\ndrawinf (50cm wide). Frame work to be finished with 19mm thick plywood (IS:710 Grade BWP,\nPrestige/Equivalent). Outer and inner portion of the storage to be finished with 1mm\nlaminate(Century/Equivalent), s per drawing. Use necessory SS hinges, SS handles, Locks etc (make:\nHettich/Ebco). Finish as per drawing with neccessory grooves, projections and electrical openings if any.\nIncluding cost of conveyance of all materials labour charges etc. | 3.02 | 16.008 | m2 |
| 89 | 4 | 1 PHE WORK | 4 | ||
| 90 | 4.01 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | 4.01 | 4 | each |
| 91 | 4.02 | Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. | 4.02 | 4 | no |
| 92 | 4.03 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | 4.03 | 4 | each |
| 93 | 4.04 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour600 mm long towel rail with total length\nof 645 mm, width 78 mm and effective height of 88 mm, weighting not less than 190 gms | 4.04 | 4 | no |
| 94 | 4.05 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore | 4.05 | 8 | each |
| 95 | 4.06 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore | 4.06 | 12 | each |
| 96 | 4.07 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm | 4.07 | 1 | each |
| 97 | 4.08 | OD Derived<br>Providing and fixing of sink cock with wall flange of approved\nquality<br>Make:Parryware/Equivalent\" | 4.08 | 1 | each |
| 98 | 4.09 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall\netc. 50 mm pipe 6 kgf/cm2 | 4.09 | 4 | m |
| 99 | 4.1 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.\n75 mm pipe 6 Kgf/cm2 | 4.1 | 9 | m |
| 100 | 4.11 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc.\n110 mm pipe 6kgf/cm2 | 4.11 | 15 | m |
| 101 | 4.12 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall | 4.12 | 2 | m |
| 102 | 4.13 | Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall | 4.13 | 3 | m |
| 103 | 4.14 | Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall | 4.14 | 6 | m |
| 104 | 4.15 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2 | 4.15 | 3 | m |
| 105 | 4.16 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 | 4.16 | 100 | m |
| 106 | 4.17 | \"OD Derived<br>Providing , fixing , testing and commissioning pvc multy inlet (110x75x50x50x50) floor trap of self cleansing design with or without vent arm complete, including cost of masonry or concrete supports cutting and making good the walls and floors where ever required\" | 4.17 | 5 | each |
| 107 | 4.18 | OD Derived<br>Providing , fixing , testing and commissioning pvc \"\"P\"\" trap with multy inlet or single inlet connection of required sizes of self cleansing design with or without vent arm complete, including cost of masonry or concrete supports cutting and making good the walls and floors where ever\nrequired\"<br> | 4.18 | 5 | each |
| 108 | 4.19 | \"OD Derived<br>Providing and fixing 100mm dia , two piece CP , air tight floor clean out plug of approved quality . 125mm square frame with 100 mm dia openable circular lid | 4.19 | 2 | each |
| 109 | 4.2 | OD Derived<br>Providing, fixing, testing and commissioning at site 100x100 mm square C.P.cast brass or stainless steel Grating Cover with protection from cockroaches of matching size of multi inlet or P trap complete in all respects. | 4.2 | 10 | each |
| 110 | 4.21 | \"OD Derived<br>Providing and fixing GI slotted rail of approved design. projecting 75 mm outside the wall surface and fixed on wall with 2 nos, 6/8 mm dia expansion hold fasteners, including drilling necessary holes in brick wall / CC / RCC surface and the cost of bolts included. The pipes shall be fixed\nto the already fixed brackets with the help of 8 mm galvanised GI \"\"U\"\" bolts of specified shape and shall be fixed with GI nuts, bolts, & washers of suitable size, one bolts on each side of the pipe. | 4.21 | 3 | m |
| 111 | 4.22 | OD Derived<br>Supply and fixing of 600x600mm DI medium duty manhole cover of class B-125 | 4.22 | 8 | each |
| 112 | 4.23 | 150x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | 4.23 | 4 | each |
| 113 | 4.24 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow | 4.24 | 2 | no |
| 114 | 4.25 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow | 4.25 | 6 | no |
| 115 | 4.26 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend | 4.26 | 2 | no |
| 116 | 4.27 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x75x75 mm dia Tee | 4.27 | 1 | no |
| 117 | 4.28 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee | 4.28 | 2 | no |
| 118 | 4.29 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl | 4.29 | 2 | no |
| 119 | 4.3 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Socket /coupling | 4.3 | 10 | no |
| 120 | 4.31 | OD Derived<br>Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Y | 4.31 | 2 | each |
| 121 | 4.32 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow | 4.32 | 4 | no |
| 122 | 4.33 | Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow | 4.33 | 4 | no |
| 123 | 4.34 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend | 4.34 | 2 | no |
| 124 | 4.35 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee | 4.35 | 1 | no |
| 125 | 4.36 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee | 4.36 | 2 | no |
| 126 | 4.37 | Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl | 4.37 | 5 | no |
| 127 | 4.38 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling | 4.38 | 12 | no |
| 128 | 4.39 | OD Derived<br>Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including\r jointing with PVC solvent cement - 110 mm dia Y<br> | 4.39 | 4 | each |
| 129 | 4.4 | OD Derived from 18.8.2<br>Providing and fixing Unplasticized Polyvinyl Chloride (uPVC) pipes ASTM D-1785, including all uPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings, with solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Internal work -Concealed on wall<br>20mm dia SCH 40 | 4.4 | 18 | m |
| 130 | 4.41 | OD Derived from 18.8.3<br>Providing and fixing Unplasticized Polyvinyl Chloride (uPVC) pipes ASTM D- 1785, including all uPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Internal work -Concealed on wall<br>25mm dia SCH 40 | 4.41 | 5 | m |
| 131 | 4.42 | OD Derived from 18.8.4<br>Providing and fixing Unplasticized Polyvinyl Chloride (uPVC) pipes ASTM D- 1785, including all uPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with solvent cement and the cost of cutting chases and making\ngood the same including testing of joints complete as per direction of Engineer-in-Charge. Internal work - Concealed on wall<br>32mm dia SCH 40 | 4.42 | 2 | m |
| 132 | 4.43 | OD Derived from 18.7.2<br>20mm dia SCH 40 | 4.43 | 6 | m |
| 133 | 4.44 | OD derived from DAR 18.7.3\nProviding and fixing Unplasticized Polyvinyl Chloride (uPVC) pipes ASTM D-1785, including all uPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Internal work - Exposed on wall 25mm SCH 40 | 4.44 | 3 | m |
| 134 | 4.45 | OD derived from DAR 18.7.4\nProviding and fixing Unplasticized Polyvinyl Chloride (uPVC) pipes ASTM D-1785, including all uPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Internal work - Exposed on wall\n32mm SCH 40 | 4.45 | 2 | m |
| 135 | 4.46 | OD derived from DAR 18.7.5\nProviding and fixing Unplasticized Polyvinyl Chloride (uPVC) pipes ASTM D-1785, including all uPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Internal work - Exposed on wall\n40mm SCH 40 | 4.46 | 6 | m |
| 136 | 4.47 | OD derived from DAR 18.7.6\nProviding and fixing Unplasticized Polyvinyl Chloride (uPVC) pipes ASTM D-1785, including all uPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Internal work - Exposed on wall\n50mm SCH 40 | 4.47 | 10 | m |
| 137 | 4.48 | OD Derived from 18.9.2\n\"Providing and fixing Unplasticized Polyvinyl Chloride (uPVC) pipes,ASTM D-1785 including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. -\nExternal Work (Burried)\"\n20mm dia SCH 40 | 4.48 | 15 | m |
| 138 | 4.49 | OD Derived from 18.9.3\n\"Providing and fixing Unplasticized Polyvinyl Chloride (uPVC) pipes,ASTM D-1785 including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. -\nExternal Work (Burried)\"\n25mm dia SCH 40 | 4.49 | 25 | m |
| 139 | 4.5 | OD derived from DAR 18.9.4\nProviding and fixing Unplasticized Polyvinyl Chloride (uPVC) pipes ASTM D-1785, including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.\n32mm SCH 40 | 4.5 | 6 | m |
| 140 | 4.51 | OD derived from DAR 18.9.5\nProviding and fixing Unplasticized Polyvinyl Chloride (uPVC) pipes ASTM D-1785, including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.\n40mm SCH 40 | 4.51 | 30 | m |
| 141 | 4.52 | OD Derived from 18.9.6\n\"Providing and fixing Unplasticized Polyvinyl Chloride (uPVC) pipes,ASTM D-1785 including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. -\nExternal Work (Burried)\"\n50mm dia SCH 40 | 4.52 | 10 | m |
| 142 | 4.53 | OD Derived from 18.18.2\n\"Providing and fixing ball valve (brass) of approved quality of following sizes.\n20mm dia\nMake: Zoloto/SKS/Cim/Equivalent\" | 4.53 | 6 | each |
| 143 | 4.54 | OD Derived from 18.18.3\n\"Providing and fixing ball valve (brass) of approved quality of following sizes.\n25mm dia\nMake: Zoloto/SKS/Cim/Equivalent\" | 4.54 | 2 | each |
| 144 | 4.55 | OD Derived from 18.18.3\n\"Providing and fixing ball valve (brass) of approved quality of following sizes.\n32mm dia\nMake: Zoloto/SKS/Cim/Equivalen | 4.55 | 1 | each |
| 145 | 4.56 | OD Derived from 18.18.3\n\"Providing and fixing ball valve (brass) of approved quality of following sizes.\n40mm dia\nMake: Zoloto/SKS/Cim/Equivalent\" | 4.56 | 1 | each |
| 146 | 4.57 | OD Derived from 18.18.3\n\"Providing and fixing ball valve (brass) of approved quality.\n50mm dia\nMake: Zoloto/SKS/Cim/Equivalent\" | 4.57 | 1 | each |
| 147 | 5 | 2 FABRICATION WORK | 5 | ||
| 148 | 5.01 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes | 5.01 | 4809.07 | Kg |
| 149 | 5.02 | Derived 12.50\nProviding and fixing of 0.5 mm thick Galvalume Roofing Sheet as per the approved design and dimension including all cost of conveyance and labour charges etc as specified and as directed by the Engineer-in-Char | 5.02 | 1150.75 | sqm |
| 150 | 5.03 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:\nRidges plain (500-600 mm) \n | 5.03 | 64 | m |
| 151 | 5.04 | \"OD Derived\nProviding and fixing 200 mm Half split PVC Square rain water Gutter Pipe with clamb and all necessary accessories required for supporting to the wall including cost of labour and making necessary connections with rain water pipes as specified and as directed by the Engineer- in-Charge.\" | 5.04 | 170 | m |
| 152 | 5.05 | Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall | 5.05 | 146 | m |
| 153 | 5.06 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.\nOn steel work | 5.06 | 630 | sqm |
| 154 | 6 | 3 EXHAUST WORK | 6 | ||
| 155 | 6.01 | Supplying & fixing of Turbo Ventilators on truss roofing. | 6.01 | 2 | each |
AI Tender Summary
Tender Timeline
Jan 18, 2021
11:30 IST
Tender Published
Tender notice published.
Completed
Jan 19, 2021
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedJan 19, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 20, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓