}

Repairs/ Maintenance Of Summer Applliance Equipments At Various Ascon Nodes And Jalipa Mil Stn Under Ge(A) Barmer., GE(A) Barmer-Rajasthan

Military Engineer Services has published Repairs/ Maintenance Of Summer Applliance Equipments At Various Ascon Nodes And Jalipa Mil Stn Under Ge(A) Barmer.. Submission Date for this Tender is 11-02-2021. Air Conditioner Tenders in GE(A) Barmer Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

26549437
Corrigendum : Repairs/ Maintenance Of Summer Applliance Equipments At Various Ascon Nodes And Jalipa Mil Stn Under Ge(A) Barmer.
Tender
Indian
Rajasthan
Ge(A) Barmer
11-02-2021

Tender Details

Repairs Maintenance Of Summer Applliance Equipments At Various Ascon Nodes And Jalipa Mil Stn Under Ge Army Barmer - 1 M&L For Hermatic Sealed Compressor Of Refrigerator 310 / 286 Ltr, Capacity With Fresh New Uncut Sealed Compressor With Suitable Relay And Over Load As Per The Company Scheme Supplied By The Manufacture Including Flushing Out System, Checking And Rectification Of Leakage, Gas Charging And Testing After Completion Of Work At Mes Store Yard Including Taking Out Old Compressor Complete All As Specified And As Directed. Nnote: - ( 1 ) The Rate Quoted By The Contractor Shall Be Inclusive Of All Charges Like Transportation, Fitting Etc Complete With Necessary Guarantee Period As Per Company Terms And Conditions N ( Ii ) The New Unit Will Be Purchased From Authorized Dealers Only. 2 M&L For Hermatic Sealed Compressor Of Refrigerator 165 / 170 / 180 Ltr, Capacity With Fresh New Uncut Sealed Compressor With Suitable Relay And Over Load As Per The Company Scheme Supplied By The Manufacture Including Flushing Out System, Checking And Rectification Of Leakage, Gas Charging And Testing After Completion Of Work At Mes Store Yard Including Taking Out Old Compressor Complete All As Specified And As Directed. Nnote: - ( 1 ) The Rate Quoted By The Contractor Shall Be Inclusive Of All Charges Like Transportation, Fitting Etc Complete With Necessary Guarantee Period As Per Company Terms And Conditions N ( Ii ) The New Unit Will Be Purchased From Authorized Dealers Only. 3 M&L For Relay Suitable For 286 / 310 Liters Capacity Refrigerator Cat. No. Mla-043, Including Taking Down Old Relay Complete All As Specified And As Directed. 4 M&L For Relay Suitable For 165 / 170 / 180 Liters Capacity Refrigerator Cat. No. Mla-042 / 033, Including Taking Down Old Relay Complete All As Specified And As Directed. 5 M&L For Thermostat Automatic R Frost With Knob Suitable For 165 / 170 / 180 / 286 / 310 Liters Capacity Refrigerator Including Taking Down Old Thermostat Complete All As Specified And Directed . 6 M&L For Door Gasket Of Best Quality Suitable For 286 / 310 Liters Capacity Refrigerator Complete As Per Manufacturers Instruction Including Taking Down Oldgasket Complete All As Specified And Directed . 7 M&L For Door Gasket Of Best Quality Suitable For 165 / 170 / 180 Liters Capacity Refrigerator Complete As Per Manufacturers Instruction Including Taking Down Old Gasket Complete All As Specified And Directed . 8 M&L For Bulb Pin / Screw Type, 230 Volts Suitable For 286 / 310 Ltrs Capacity Refrigerator Including Taking Down Old One Complete All As Specified And Directed . 9 M&L For Freezer Door Including Necessary Door Springs, Screws Etc. For 286 / 310 Ltrs. Capacity Refrigerator Including Taking Down Old Door Complete All As Specified And Directed . 10 M&L For Freezer Door Including Necessary Door Springs, Screws Etc. For 165 / 170 / 180 Liters. Capacity Refrigerator Including Taking Down Old Door Complete All As Specified And Directed . 11 M&L For Door Lock With 02 Nos Keys Suitable For Any Capacity Refrigerator, Including Taking Down Old Lock Complete All As Specified And Directed . 12 M&L For Pvc Chill Tray Suitable For 286 / 310 Ltrs Capacity Refrigerator Of Matching Colour Or Tint Including Taking Down Old Tray Complete All As Specified And Directed . 13 M&L For Pvc Chill Tray Suitable For 165 / 170 / 180 Ltrs Capacity Refrigerator Of Matching Colour Or Tint Including Taking Down Old Tray Complete All As Specified And Directed . 14 Preparation Of Old Painted Steel Surfaces Of Refrigerator Capacity 286 / 310 Ltrs And Painting With Applying Two Coats Of Synthetic Enamel Paint On External Surfaces Of Refrigerator Except Cooling Coil And Compressor Unit Which Will Be Painted With Two Coats Of Heat Resistant Black Paint Including Writing Of The Words In Height 4Cm I.E. Sm No. Mes No. Cb No. And Ca No. Ge ( A ) Bmr- Of 2020-21 Complete All As Specified And As Directed. Nnote: Refrigerators To Be Painted At Different Locations Of Different Units. 15 Preparation Of Old Painted Steel Surfaces Of Refrigerator Capacity 165 Ltrs And Painting With Applying Two Coats Of Synthetic Enamel Paint On External Surfaces Of Refrigerator Except Cooling Coil And Compressor Unit Which Will Be Painted With Two Coats Of Heat Resistant Black Paint Including Writing Of The Words In Height 4Cm I.E. Sm No. Mes No. Cb No. And Ca No. Ge ( A ) Bmr- Of 2020-21 Complete All As Specified And As Directed. Nnote: Refrigerators To Be Painted At Different Locations Of Different Units. 16 M&L For Refrigerator Door Handle Suitable 165 / 286 / 310 Ttrs Capacity Including Taking Down Old Handle Complete All As Specified And As Directed. 17 M&L For Freezer Assembly Including Gas Charging 286 / 310 Ltrs Capacity Refrigerator Including Taking Down Old Assembly Complete All As Specified And As Directed. 18 M&L For Freezer Assembly Including Gas Charging 165 / 170 / 180 Ltrs Capacity Refrigerator Including Taking Down Old Assembly Complete All As Specified And As Directed. 19 M&L For Condensor Unit Of Refrigerator Capacity 286 / 310 Ltrs Including Jointing Of Tubes And Testing Including Taking Down Old Unit Complete All As Specified And As Directed. Nnote: Gas Charging Will Be Measured And Paid For Separately. 20 M&L For Condensor Unit Of Refrigerator Capacity 165 Ltrs Including Jointing Of Tubes And Testing Including Taking Down Old Unit Complete All As Specified And As Directed. Nnote: Gas Charging Will Be Measured And Paid For Separately. 21 M&L For Hermatic New Uncut Sealed Compressor Unit Of Window Type / Split Type Acs 1.5Tr Capacity Including Wiring As Required To Unit With Flushing Out System, Checking And Rectification Of Leakage, Gas Charging And Testing After Completion Of Work At Mes Store Yard For Satisfactory Functioning Including Taking Out Unserviceable Cut Sealed Compressor Unit Complete All As Specified And As Directed. Nnote: - The New Compressor Unit Will Be Purchased From Authorized Dealers Only As Per Existing Make And Model. 22 M&L For Rewinding Of Blower Motor 1 / 5 Hp Of Speed 900 Rpm Of Window / Split Air Conditioner ( Any Make ) With Super Enameled Copper Wire Including Replacement Of Worn Out Bushes, Shaft And Capacitor Etc And Testing Complete All As Specified And As Directed. 23 M&L For Condensor Fan Motor Of Speed 900 Rpm Of Window / Split Air Conditioner Of Capacity 1.5 Tr Including Taking Down Old Condensor Complete All As Specified And As Directed. 24 M&L For Running Capacitor ( Clip Type ) 36 Mfd, 240 Volts 50 Cycles For Window Type Air Conditioner 1.5 Ton Capacity Including Taking Down Old Capacitor Complete All As Specified And As Directed. 25 M&L For Starting Capacitor ( Clip Type ) 80-100 Mfd, 240 Volts 50 Hz For Window Type Air Conditioner Including Taking Down Old Capacitor Complete All As Specified And As Directed. 26 M&L For Over Load Protector Relay Model No 1622 / 2085 For 1.5 Ton Capacity Window Type Ac Including Taking Down Old Protector Complete All As Specified And As Directed. 27 M&L For Thermostat Switch For Window Type Ac 1.5 / 2.00 Ton Capacity Including Taking Down Old Switch Complete All As Specified And As Directed. 28 M&L For Replacement Of Defective Wiring Set ( With Suitable Copper Wire ) Of Window Type Ac 1.5 / 2 Ton Capacity Complete All As Specified And As Directed. 29 Flushing Out System, Checking And Rectification Of Leakages If Any And Make It Serviceable Including Gas Charging With Refrigerant R-22, Oil Changing In Compressor For Window Type Ac / Split Type Ac Capacity 1.5 Ton Complete All As Specified And As Directed. 30 Flushing Out System, Checking And Rectification Of Leakages If Any And Make It Serviceable Including Gas Charging With Refrigerant R-22, Oil Changing In Compressor For 286 / 310 Ltr Capacity Refrigerator Complete All As Specified And As Directed. 31 Flushing Out System, Checking And Rectification Of Leakages If Any And Make It Serviceable Including Gas Charging With Refrigerant R-22, Oil Changing In Compressor For165 / 170 / 180 Ltr Capacity Refrigerator Complete All As Specified And As Directed. 32 M&L For Cooling Coil For Window Type Ac 1.5 / 2.0 Ton Capacity Including Taking Down Old Coil Complete All As Specified And As Directed. 33 M&L For Fan Blade Of Condensor Fan Motor Of Window / Split Air Conditioner Of Capacity 1.5 Tr Including Taking Down Old Blade Complete All As Specified And As Directed. 34 Taking Out Carefully Window Type Ac Of Any Capacity And Make For Servicing Including Cleaning With Air Blower, Cleaning And Washing Fins Of Cooling Coil With Caustic Soda Mixed Water, Taking Out All Dirt, Sludge Deposited, Cleaning Of Air Filter Including Oiling / Greasing Of Condensing Fan Motor, Spray Painting Of Outer Cover With 2 Coats Of Synthetic Enameled Paint Of Approved Colour As Directed With Writing Of Serial No. Sm / Mes No. And Reinstalled The Ac In Position With Fixing Of Putty Etc. Complete All As Specified And As Directed . Nnote: Any Damage Occurred During Servicing For Which Contractor Will Be Responsible To Rectify The Same Without Any Extra Cost To The Govt. 35 Servicing / Overhauling Of Split Type Ac Unit Capacity 1.5 Ton Including Painting To Outer Cover And Components With Two Coats Of Synthetic Enameled Paint Of Approved Colour As Directed Including Following Complete All As Specified And As Directed :-- N ( A ) Cleaning And Descaling Of Condensing Unit And Cooling Coil With Caustic Soda Mixed Water And Air Blower And Taking Out All Dirt / Sludge Etc Complete N ( B ) Greasing / Oiling Of Blower Fan Motor N ( C ) Charging The Gas As Required To Full Fill The Rated Cooling Effect. 36 M&L For Capacitor 4 Mfd Suitable For 1.5 Ton Capacity Split Type / Desert Cooler Including Taking Down Old Capacitor Complete All As Specified And As Directed. 37 M&L For Connector Unit Suitable For Split Type Ac 1.5 Ton Capacity Including Taking Down Old Unit Complete All As Specified And As Directed. 38 M&L For Blade For Condensing Fan Motor Suitable For Split Type Ac 1.5 Ton Capacity Including Taking Down Old Blade Complete All As Specified And As Directed. 39 M&L For Capacitor 6 Mfd Suitable For Split Type Ac Including Taking Down Old Capacitor Complete All As Specified And As Directed. 40 M&L For Foam Type Insulated Flexible Pipe Suitable For Suction / Discharge Copper Tubes Fitted On Split Ac Including Taking Down Old Pipe Complete All As Specified And As Directed. 41 M&L For Submain Wiring With Two Runs Of 6 Sqmm With One Run Of 6 Sqmm Earth Wire Of 1100V Grade Frls Pvc Insulated Multi-Stranded Copper Conductor, Single Core Cable Conforming To Is 694 Drawn Through And Including 20Mm Dia Pvc Conduit With Accessories Fixed On Wall / Ceiling With Pvc Saddles And Cadmium Plated Steel Screws And Connected To Common Earth Dolly Including Taking Down Old Submain Wiring Complete All As Specified And Directed. Nnote :- Three Runs Of 6 Sqmm And One Run Of Pvc Conduit Pipe Shall Be Measured As One Length For The Purpose Of Measurement. 42 M&L For Single Pole And Neutral Enclosure With 2 Pin Earth Industrial Plug And Socket With One Mcb Sp 25 Amps Including Taking Down Old One Complete All As Specified And As Directed. 43 M&L For Harmatically New Uncut Sealed Compressor Suitable For Water Cooler Cooling Capacity 40 Litrs / Hour Including Filling Oil, Gas Charging, Flushing Out System, Checking And Rectification Of Leakage And Testing Including Taking Down Old Compressor Complete All As Specified And As Directed. 44 M&L For Copper Filter And Capillary Tube Of Water Cooler Of Cooling Capacity 40 Ltr / Hr Including Taking Down Old Filter Complete All As Specified And As Directed. 45 M&L For Relay With Over Load Protectors Suitable For 40 Ltr / Hr Cooling Capacity Water Cooler Including Taking Down Old Relay Complete All As Specified And As Directed. 46 M&L For Condensor Fan Motor Hp- 1 / 32, Rpm-1300 With Fan Blade Suitable For Water Cooler Having Cooling Cap 40 Ltr / Hr With Clips And Motor Fixed To Stand Including Taking Down Old Condensor Complete All As Specified And As Directed. 47 M&L For Thermostat Switch With Knob For Water Cooler Having Cooling Capacity 40 Ltrs / Hr Including Taking Down Old Switch Complete All As Specified And As Directed. 48 Patch Repair Work Of Worn Out Ms Body Of Water Cooler Any Capacity Made Out Of 22 Gauge Mild Steel Sheet ( Approximate 0.25 Sqm Area Of Each Patch ) And Making Good With Paint To Match With Existing Complete All As Specified And As Directed. 49 M&L For Pvc Pipe 25Mm Bore, 70Cm In Long Fixed With 2 Nos Ms Clamps With Screws For Water Cooler Including Taking Down Old Pipe Complete All As Specified And As Directed. 50 M&L For Drip Tray Made Out Of 24 Gauge Stainless Steel Sheet 30X12x5 Cm Deep With Necessary Gi And Pvc Connection For Water Cooler Of 40 / 60 Litre Per Hour Including Taking Down Old Tray Complete All As Specified And As Directed. 51 M&L For Rubber Beading Fixed To Top Cover Of Water Cooler Of 40 Litre Per Hour Including Taking Down Old Beading Complete All As Specified And As Directed. 52 M&L For Condensor Fan Motor Mounting Stand Made Out Of Mild Steel Sheet 3Mm Thick Of Suitable Size And Fixed On Existing Base Including Taking Down Old Fan Motor Complete All As Specified And As Directed. 53 M&L For Push Cock, 15Mm Bore Made Of Brass Chromium Plated Self Closing, Vertical Type Including Taking Down Old Cock Complete All As Specified And As Directed. 54 Spray Painting To Water Cooler Of Capacity 40 / 60 Ltrs / Hour With Two Coats Of Synthetic Enamel Paint ( First Quality ) And Preparation Of Surface Including Cleaning And Washing Condenser, Writing Mes No Complete All As Specified And Directed By Engineer-In-Charge. Nnote: Painting To Be Carried Out At Various Location Of Units. 55 M&L For Brass Float Valve 15Mm Bore With Pvc Float Ball ( Isi Marked ) With Check Nut / Socket / Gi Nipple Including Taking Down Old Float Valve Complete All As Specified And As Directed. 56 M&L For Top Cover Of Water Cooler With Rubber Beading, Hinges, Screws Etc Suitable For Water Cooler Having Cooling Capacity 40 Ltrs.Per Hour Including Taking Down Old Top Cover Complete All As Specified And As Directed. 57 Flushing Of System, Testing And Repairs Of Leakages In System, Charging Of Gas, Oil Etc Including Testing And Commissioning Of Water Cooler Having Cooling Capacity 40 Ltrs.Per Hour Complete All As Specified And As Directed. 58 M&L For Fan Blade For Condensing Fan Motor Suitable For Water Cooler Having Cooling Capacity 40 Ltr Per Hour Including Taking Down Old Fan Blade Complete All As Specified And As Directed. 59 M&L For Condenser Unit Complete Suitable For 40 Ltr / Hr Capacity Water Cooler Including Gas Charging, Flushing Out The System, Brazing, Welding And Jointing The Suction Reed And Discharge Reed Including Taking Down Old Condensor Unit Complete All As Specified And As Directed. 60 M&L For Rewinding Desert Cooler Fan Motor 3 Speed, 1400 Rpm Of Capacity 1 / 5 Hp With Super Enameled Copper Wire Of Appropriate Size Including Replacement Of Bush, Shaft And Capacitor 4 Mfd, 240 Volts Complete All As Specified And As Directed. 61 M&L For Front Grill ( Moveable ) Of The Desert Cooler Made Out Of 20 Gauge Pgi Sheet Including Selector Switch With Knob, Indicator Etc Suitable For 4000 / 5000 Cfm Desert Cooler Including Taking Down Old Grill Complete All As Specified And As Directed. 62 M&L For Bottom Water Tank Of Desert Cooler Of Size 750 X 750 X 200Mm Fabricated Out Of 18 Gauge Pgi Sheet Including Nuts Bolts And Washers Etc Including Taking Down Old One Complete All As Specified And As Directed. 63 M&L For Side Supporting Columns Made Out Of 20 Gauges Pgi Sheet Of Size 80 X 80 X 800Mm With Necessary Nut, Bolts Etc Including Painting To Match With The Existing Desert Cooler Including Taking Down Old One Complete All As Specified And As Directed. 64 M&L For Side Panel Made Out Of 22 Gauge Pgi Sheet With Suitable Handles Including Painting To Match With The Existing Desert Cooler Including Taking Down Old Side Panel Complete All As Specified And As Directed. 65 M&L For Top Cover Made Out Of 22 Gauge Pgi Sheet With Suitable Handles Including Painting To Match With The Existing Desert Cooler Including Taking Down Old Top Cover Complete All As Specified And As Directed. 66 Spray Painting To Old Steel Surfaces Of Desert Cooler Up To 5000 Cfm With Two Coats Of Synthetic Enamel Paint Over One Coat Of Red Oxide Primer On External Surface And Two Coats Of Anti-Corrosive Black Paint Over A Coat Of Red Oxide Primer On Inside The Body Tank And Side Grills Including Scraping / Rubbing With Wire Brush On Old Surface Of Desert Cooler And Writing Mes No. Etc Complete All As Specified And Directed. 67 M&L For Desert Cooler Fan Motor Capacity 1 / 5 Hp Three Speed, 1400 Rpm Single Phase With Fan Blade, Stand And Selector Switch Including Taking Down Old Motor Complete All As Specified And As Directed. 68 M&L For Submersible Pump Of Discharge Head 2.5 Mtr 220-240 Volts Ac Supply Single Phase 40 Watt Including Taking Down Old Pump Complete All As Specified And As Directed. 69 M&L For Wood / Wool Chips Pad For Desert Cooler Of Size 600 X 550 X 30Mm ( Set Of Three Pads ) Superior Quality Complete All As Specified And Directed Including Taking Down Old Pads Complete All As Specified And As Directed. 70 M&L For Supporting Jali To Wood / Wool Chips Pad Set Made Out Of Hard Ms Wire And Fitted Inside Louvers ( Set Of Three ) Complete All As Specified And Directed Including Taking Down Old Jali Complete All As Specified And As Directed. 71 M&L For Selector Switch With Knob Three Speed Suitable For Fan Motor Including Taking Down Old Switch Complete All As Specified And As Directed. 72 M&L For Pvc Insulated And Pvc Sheathed Cable Copper Conductor 3 Core 23 / 0.0076 Cross Sectional Area ( Superior Quality ) Including Taking Down Old Cable Complete All As Specified And As Directed. 73 M&L For Pvc Water Distributor Of 3 Out Lets With Ms Nuts & Bolts Including Taking Down Old One Complete All As Specified And As Directed. 74 M&L For Pvc Elbow Suitable For Desert Cooler Including Taking Down Old Elbow Complete All As Specified And As Directed. 75 M&L For Pvc Pipe 15Mm Dia Heavy Duty For Desert Cooler Pump Including Taking Down Old Pipe Complete All As Specified And As Directed. 76 M&L For Plug Top 3 Pin Of Capacity 5 Amp Ac 240 Volts 50 Hz Including Taking Down Old Plug Top Complete All As Specified And As Directed. 77 M&L For Motor Fixing Ring With Eight Screw ( Clip Type ) For Desert Cooler Including Taking Down Old One Complete All As Specified And As Directed. 78 Repairs To 5 Kva Voltage Stabilizer Single Phase Input 180 To 250 Volts, Out Put Voltage Stabilizer 230 V Including Replacement Of Worn Out / Short Circuit / Pointed Circuit Board, Voltmeter, 15 / 5 Amp Socket, Relay Etc, Testing Complete All As Specified And As Directed. Nnote : Cost Of Replacement Parts Shall Include In Quoted Rates. 79 Repairs To 3 Kva Voltage Stabilizer Single Phase Input 180 To 250 Volts, Out Put Voltage Stabilizer 230 V Including Replacement Of Worn Out / Short Circuit / Pointed Circuit Board, Voltmeter, 15 / 5 Amp Socket, Relay Etc, Testing Complete All As Specified And As Directed. Nnote : Cost Of Replacement Parts Shall Include In Quoted Rates. 80 M&L For Hermatic Sealed Compressor Of Deep Freezer 500 Ltr, Capacity With Fresh New Uncut Sealed Compressor With Suitable Relay And Over Load As Per The Company Scheme Supplied By The Manufacture Including Flushing Out System, Checking And Rectification Of Leakage, Gas Charging And Testing After Completion Of Work At Mes Store Yard Including Taking Out Old Compressor Complete All As Specified And As Directed. Nnote: - ( 1 ) The Rate Quoted By The Contractor Shall Be Inclusive Of All Charges Like Transportation, Fitting Etc Complete With Necessary Guarantee Period As Per Company Terms And Conditions N ( Ii ) The New Unit Will Be Purchased From Authorized Dealers Only. 81 M&L For Hermatic Sealed Compressor Of Deep Freezer 320 Ltr, Capacity With Fresh New Uncut Sealed Compressor With Suitable Relay And Over Load As Per The Company Scheme Supplied By The Manufacture Including Flushing Out System, Checking And Rectification Of Leakage, Gas Charging And Testing After Completion Of Work At Mes Store Yard Including Taking Out Old Compressor Complete All As Specified And As Directed. Nnote: - ( 1 ) The Rate Quoted By The Contractor Shall Be Inclusive Of All Charges Like Transportation, Fitting Etc Complete With Necessary Guarantee Period As Per Company Terms And Conditions N ( Ii ) The New Unit Will Be Purchased From Authorized Dealers Only. 82 M&L For Relay Suitable For 200 / 320 Ltrs Capacity Deep Freezer Including Taking Down Old Relay Complete All As Specified And As Directed. 83 M&L For Relay Suitable For 500 Ltrs Capacity Deep Freezer Cat. No. Mla-042 / 033, Including Taking Down Old Relay Complete All As Specified And As Directed. 84 M&L For Thermostat Automatic R Frost With Knob Suitable For 200 / 320 / 500 Liters Capacity Deep Freezer Including Taking Down Old Thermostat Complete All As Specified And Directed . 85 M&L For Door Gasket Of Best Quality Suitable For 200 / 320 Ltrs Capacity Deep Freezer Complete As Per Manufacturers Instruction Including Taking Down Oldgasket Complete All As Specified And Directed . 86 M&L For Door Gasket Of Best Quality Suitable For 500 Ltrs Capacity Deep Freezer Complete As Per Manufacturers Instruction Including Taking Down Oldgasket Complete All As Specified And Directed . 87 M&L For Freezer Door Including Necessary Door Springs, Screws Etc. For 200 / 320 Ltrs. Capacity Deep Freezer Including Taking Down Old Door Complete All As Specified And Directed . 88 M&L For Condensor Unit Of Deep Freezer Capacity 200 / 320 Ltrs Including Jointing Of Tubes And Testing Including Taking Down Old Unit Complete All As Specified And As Directed. Nnote: Gas Charging Will Be Measured And Paid For Separately. 89 M&L For Condensor Unit Of Deep Freezer Capacity 500 Ltrs Including Jointing Of Tubes And Testing Including Taking Down Old Unit Complete All As Specified And As Directed. Nnote: Gas Charging Will Be Measured And Paid For Separately. 90 Flushing Out System, Checking And Rectification Of Leakages If Any And Make It Serviceable Including Gas Charging With Refrigerant R-22, Oil Changing In Compressor Of Deep Freezer Capacity 200 / 320 Ltrs Complete All As Specified And As Directed. 91 M&L For Condensor Fan Motor Of Speed 1300 Rpm With Fan Blades Suitable For Deep Freezer Capacity 320 Ltrs With Clips And Motor Fixed To Stand Including Taking Down Old Condensor Complete All As Specified And As Directed. 92 M&L For Condensor Fan Motor Of Speed 1300 Rpm With Fan Blades Suitable For Deep Freezer Capacity 500 Ltrs With Clips And Motor Fixed To Stand Including Taking Down Old Condensor Complete All As Specified And As Directed.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 01-02-2021 POSTPONEMENT Date 04-02-2021
2 06-02-2021 POSTPONEMENT2 Date 11-02-2021
3 13-01-2021 AMENDMENT Other 22-01-2021
4 22-01-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-01-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail