Petty Repair For Attending Day To Day Em External Water Complaints At Rrrc Area Lorry Road Army Training Area And D K Part I And Allied Area In The Area Of Age U Ws No Ii Under Ge U Water Supply Delhi Cantt 10, GE U WATER SUPPLY DELHI CANTT 10-Delhi

Military Engineer Services-MES has published Petty Repair For Attending Day To Day Em External Water Complaints At Rrrc Area Lorry Road Army Training Area And D K Part I And Allied Area In The Area Of Age U Ws No Ii Under Ge U Water Supply Delhi Cantt 10. Submission Date for this Tender is 03-02-2021. Electromechanical Work Tenders in GE U WATER SUPPLY DELHI CANTT 10 Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

26533821
Corrigendum : Petty Repair For Attending Day To Day Em External Water Complaints At Rrrc Area Lorry Road Army Training Area And D K Part I And Allied Area In The Area Of Age U Ws No Ii Under Ge U Water Supply Delhi Cantt 10
National Competitive Bid
Indian
Delhi
GE U WATER SUPPLY DELHI CANTT 10
03-02-2021

Tender Details

Petty Repair For Attending Day To Day Em External Water Complaints At Rrrc Area Lorry Road Army Training Area And D K Part I And Allied Area In The Area Of Age U Ws No Ii Under Ge U Water Supply Delhi Cantt 10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Jan-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-02-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 32000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: PETTY REPAIR FOR ATTENDING DAY TO DAY E/M EXTERNAL WATER COMPLAINTS AT RRRC AREA, LORRY ROAD, ARMY TRAINING AREA AND D K PART-I AND ALLIED AREA IN THE AREA OF AGE (U) W/S NO II UNDER GE (U) WATER SUPPLY, DELHI CANTT - 10
S.No Description of work Item Code / Make Quantity Units
1 1 Labour only for attending day to day external/treated water supply complaints of all nature i.e leakage in water supply pipe lines , fitting/fixture, over flow of overhead tank, no water supply,taking out water from trenches during repair including noting the complaints in complaint register complete all as specified and as directed. (Any material required for attending complaints shall be measured and paid separately under respective item herein after) Note :- quoted rates include notes mentioned at srl No. 3 (i) to 3 (ix). 2400 Each Job
2 2 Labour only for attending of Electric supply compliants of day to day maintenace of existing LT Panels including connecting electrical accessories / spares of water supply installation and electrical fitting & light, short circuits in Pump house complete all as specified and as directed. (Any material required for attending complaints shall be measured & paid separately under respectvie item hereinafter)\nNote :- Quoted rates include notes mentioned at srl No. 3 (i) to 3 (ix) 70 Each Job
3 3 Notes for item No. 1.00 & 2.00 (i) The complaints shall be attended and the defects shall be rectified by a team of expert and experienced electrician/plumber as applicable assisted with adequate No of helpers complete all as specified and as directed.
4 3.01 (ii) The complaints shall be attended and defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 250/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues.Contractor rep shall be available wef 0800 hrs to 2000 Hrs to receive and notify the complained
5 3.02 (iii) In case, after checking and attending the defect, it is not possible to rectify the defects within 08 hrs the facts shall be brought to the notice of Engineer-in -charge by the contractor /his rep . If Engineer -in-charge is satisfied with contractors view, no recovery will be made.
6 3.03 (iv) while attending the complaint of water supply /Electric supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A' . However no extra payments shall be made for dewatering.\n
7 3.04 (v) Cutting of GI pipe in position and threading is also deemed to be included in the job rate (Fitting and fixtures will be measured and paid separetely under respective item of Sch A.
8 3.05 (vi) All T & P required for attending the complaints shall be provided by the contracor.
9 3.06 (vii) The pipe fitter shall always be in possession of die set complete with cutters , Taps , Pipe wrench, Chain wrench,Caulking tools, Complete set of spanners and ladders etc…, as required at site.
10 3.07 (viii) The elecrician shall always be in possession of all Electrician tools , LT Megger, Earth tester , Multimeter , Crimping tool, insulation tape, Hand gloves etc required at site.
11 4 Supply only GI Socket, heavy duty, ISI Marked complete all as specified and as directed of following sizes.
12 4.01 15 mm bore\n 60 EACH
13 4.02 20 mm bore 120 EACH
14 4.03 25 mm bore 60 EACH
15 4.04 40 mm bore 10 EACH
16 4.05 50 mm bore 30 EACH
17 4.06 80 mm bore 5 EACH
18 5 Supply only GI Elbow, heavy duty, ISI Marked complete all as specified and as directed of following sizes.
19 5.01 15 mm bore\n 60 EACH
20 5.02 20 mm bore 120 EACH
21 5.03 25 mm bore 60 EACH
22 5.04 40mm bore 10 EACH
23 5.05 50mm bore 20 EACH
24 6 Supply only GI Union, medium grade, ISI Marked complete all as specified and as directed of following sizes.
25 6.01 15 mm bore\n 80 EACH
26 6.02 20 mm bore 130 EACH
27 6.03 25 mm bore 60 EACH
28 6.04 40 mm bore 10 EACH
29 6.05 50 mm bore 30 EACH
30 7 Supply only GI Nipple of different length as per requirement, both end screwed Medium Grade, ISI marked of following sizes:-
31 7.01 15 mm bore\n 60 EACH
32 7.02 20 mm bore 120 EACH
33 7.03 25 mm bore 60 EACH
34 7.04 40mm bore 10 EACH
35 7.05 50mm bore 30 EACH
36 8 Supply only PVC 'L' type Holder suitable for Aluminium rod,Float Ball etc complete all as specified and as directed
37 8.01 15 mm bore 10 EACH
38 8.02 20 mm bore 10 EACH
39 8.03 25 mm bore 5 EACH
40 9 Supply only GI reducing socket, medium grade, ISI Marked complete all as specified and as directed of following sizes.
41 9.01 25 mmx15mm bore\n 30 EACH
42 9.02 20mmx15mm bore 40 EACH
43 9.03 25 mm x 20 mm bore 20 EACH
44 9.04 50 mmx 40mm bore 10 EACH
45 9.05 40 mmx 20mm bore 5 EACH
46 9.06 40 mmx 25mm bore 5 EACH
47 9.07 50mmx 25mm bore 10 EACH
48 9.08 80 mm x50/40/25mm bore 10 EACH
49 10 Supply only GI Tee, Medium Grade, complete all as specified and as directed of following sizes
50 10.01 15mm x15mm x15mm\n 40 EACH
51 10.02 20 mm x 20 mm x 15 mm 80 EACH
52 10.03 20 mm x 20 mm x 20 mm 120 EACH
53 10.04 25 mm x 25 mm x 25 mm 30 EACH
54 10.05 25 mm x 25 mm x 15 mm 20 EACH
55 10.06 25 mm x 25 mm x 20 mm 15 EACH
56 10.07 40 mm x 40 mm x 40 mm 5 EACH
57 10.08 40 mm x 40 mm x 20 mm 5 EACH
58 10.09 40 mm x 40 mm x 25 mm 5 EACH
59 10.1 50 mm x 50 mm x 50 mm 10 EACH
60 10.11 50 mm x 50 mm x 25 mm 5 EACH
61 10.12 50 mm x 50 mm x 20 mm 10 EACH
62 11 Supply only GI plug, solid, heavy duty, complete all as specified and as directed of following sizes.
63 11.01 15mm bore \n 15 EACH
64 11.02 20 mm bore 30 EACH
65 11.03 25 mm bore 25 EACH
66 11.04 40 mm bore 10 EACH
67 11.05 50 mm bore 10 EACH
68 12 Supply Only lead pig bar complete all as specified and as directed. 220 KG
69 13 Supply Only Spurn Yarn complete all as specified and as directed. 60 KG
70 14 Supply Only Lead wool complete all as specified and as directed. 30 KG
71 15 Supply Only Gland Packing any size complete all as specified and as directed. 5 KG
72 16 Supply only M-seal in 500 gm pack complete all as specified and as directed. 15 PER PACK
73 17 Supply Only 3 mm thick rubber gasket complete all as specified and as directed.\n 15 EACH
74 18 Supply only 25 to 150 mm long, 6 to 20 mm dia nuts, bolts & washers complete all as specified and as directed.\n 20 KG
75 19 Supply only Gun metal air release valve, 25 mm bore as per IS complete all as specified and as directed. 10 EACH
76 20 Tank nipple suitable for HDPE water tank 20 mm dia 40 EACH
77 21 Supply only PTMT float valve with epoxy coated aluminium rod and high density plastic ball of following sizes complete all as specified and as directed.
78 21.01 15mm bore \n 180 EACH
79 21.02 20 mm bore 350 EACH
80 21.03 25 mm bore 50 EACH
81 21.04 50 mm bore 5 EACH
82 22 Supply only gun metal gate valve with iron wheel head screwed both ends for iron pipe , ISI marked , as per IS : 778 of following sizes complete all as specified and as directed.
83 22.01 15mm bore \n 25 EACH
84 22.02 20 mm bore 40 EACH
85 22.03 25 mm bore 20 EACH
86 22.04 40 mm bore 10 EACH
87 22.05 50 mm bore 15 EACH
88 23 Testing of drining water collected from local source (bore wells /shallow wells in the area of AGE(U) W/S No.II and submission of detailed test report to the office of Engineer-in-Charge. \n(i) Carrying out minimum essential testing of water as per IS 10500-2012 mandatory for chemical colour, odour, taste, turbidity, PH value, TDS total hardness, iron, chloride, fluoride and residual free chlorine and Bacteriological total coliform organisms per 100 ml (MPN) and E Coli in 100 ml) with specific recommendation regarding suitability of water for drinking purposes. \n(ii) Collection of water from[ different sources of water ie. Sump, bore wells & shallow well in a sterilized bottle and testing in NABL Approved laboratory as mentioned in specification \nNote :- Rate Quoted shall also deemed to be included for the followings:- \n (i) Cost of sterilized bottle as required. \n(ii) To and fro transportation charges for collection of samples from source (sump, bore & shallow wells) 10 EACH JOB
89 24 Excvation in trenches not exc. 1.5 mtr wide and not exc 1.5 mtr deep for pipe line in soft/loose soil, getting out and levelling of bottom surface to required complete all as specified and as directed. 220 CUM
90 25 Returning filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed. 198 CUM
91 26 Removing excavated material from site to a distance not exc 50 m away and depositing where directed not exc 1.5 meters above the starting point complete all as specified and as directed. 22 CUM
92 27 Surface dressing of uneven surfaces of the natural ground, rough excavated surfaces and filled area where ordered shall be trimed to an even surface horizontal or slopping, by removing vegetation and by scrapping high patches and filling low patches with the scrapping soil to given an even and neat look to the site. depth of cutting not exceeding 15 cm. complete all as specified and as directed. 100 PER SQM
93 28 Supply only 15 mm bore Bib tap of PTMT, any tint, high pressure screwed for male/ female threaded, for pipe of size 15 mm bore complete all as specified and as directed 210 EACH
94 29 Labour work required for taking out suction pipe 80 mm to 200 mm bore from sump of any capacity, dismantling of foot valve screwed / flanged type, and relowering after refixing in position the same duly cleaned / minor repair if any required such as replacement of rubber gasket/ lifting bolts & nuts including making thread for the suction pipes off sizes etc complete all as required and as directed. 10 EACH JOB
95 30 Supply only 'stem' made out from SS (all as per sample) of sluice valve of size as under : -
96 30.01 80 mm bore 1 EACH
97 30.02 100 mm bore 2 EACH
98 30.03 150 mm bore 2 EACH
99 30.04 200 mm bore 1 EACH
100 31 Supply only 'stem nut' made out from stainless steel suitable to match with existing sluice valve of sizes as under : -
101 31.01 80 mm bore 1 EACH
102 31.02 100 mm bore 2 EACH
103 31.03 150 mm bore 2 EACH
104 31.04 200 mm bore 1 EACH
105 32 Supply only 'gland plate' made out CI, suitable to match with existing sluice valve of sizes as under :
106 32.01 80 mm bore 1 EACH
107 32.02 100 mm bore 2 EACH
108 32.03 150 mm bore 2 EACH
109 32.04 200 mm bore 1 EACH
110 33 Supply & Fixing rotational moulded Poly-ethylene ISI water storage tanks (cylindrical vertical with closed top) of cap 500 Ltrs hoisted and fixed in position at building top. 2 EACH
111 34 Ditto, but cap of 1000 Ltrs PVC water storage tank 2 EACH
112 35 Taking up or down steel tubing with connection including cleaning for removal complete all as specified and as directed of the follwing sizes :-
113 35.01 15 mm dia 200 RM
114 35.02 20 mm dia 370 RM
115 35.03 25 mm dia 220 RM
116 35.04 40 mm dia 100 RM
117 35.05 50 mm dia 150 RM
118 36 Relaying/refixing only jointing and testing of old GI pipes including cleaning completely in trenches complete all as specified and as directed for the following sizes :-
119 36.01 20 mm dia 70 RM
120 36.02 25 mm dia 70 RM
121 36.03 40 mm dia 40 RM
122 36.04 50 mm dia 50 RM
123 37 Supplying and fixing GI pipe medium grade ISI marked including all fittings in old/new position as in walls and ceilling complete all as specified and as directed of following sizes :-
124 37.01 15 mm dia 100 RM
125 37.02 20 mm dia 100 RM
126 37.03 25 mm dia 50 RM
127 37.04 40 mm dia 20 RM
128 38 Supplying and fixing GI pipe medium grade ISI marked including all fittings in old/new position as in trenches complete all as specified and as directed of following sizes :-
129 38.01 15 mm dia\n 100 RM
130 38.02 20 mm dia 200 RM
131 38.03 25 mm dia 100 RM
132 38.04 40 mm dia 40 RM
133 38.05 50 mm dia 100 RM
134 39 Labour for cutting and screwing existing steel tubing for alteration or addition complete all as specified and as directed of the following sizes :-
135 39.01 15mm bore \n 10 EACH
136 39.02 20 mm bore 10 EACH
137 39.03 25 mm bore 10 EACH
138 39.04 40 mm bore 5 EACH
139 39.05 50 mm bore 5 EACH
140 40 Supply only cast iron/ DI fitting for flanged /spigot and socketed pipes such as bends , reducer, tee pieces , tail pieces , collar, cross , caps & plug upto 150mm bore 250 KG
141 41 Taking up or down Cast Iron/Cemented water mains (including all fittings) with spigot & socket ends and lead/tyton joints including burning out lead joints and recovering lead complete all as specified and directed of the following sizes :-
142 41.01 80 mm bore \n 64 RM
143 41.02 100 mm bore 140 RM
144 41.03 150 mm bore 140 RM
145 41.04 200 mm bore 33 RM
146 42 Relaying/ Refixing only in trenches CI/DI pipes with socket and spigot ends, cleaning thoroughly and removal of all blockages if any complete all as specified and as directed for the following size/bore of pipes. \nNote : Joints and CI/DI fittings shall be measured and paid seperately
147 42.01 80 mm bore 20 RM
148 42.02 100 mm bore 40 RM
149 42.03 150 mm bore 40 RM
150 42.04 200 mm bore 11 RM
151 43 Supplying, laying, jointing, testing and commmisioning of DI Pipe as per IS 8329, class K-7 with inside cement mortar lining with spigot and socket ends laid in trenches including tyton joint(Rubber gasket joint) all complete all as specified and as directed by site for the following sizes :-
152 43.01 80 mm bore 44 RM
153 43.02 100 mm bore 100 RM
154 43.03 150 mm bore 100 RM
155 43.04 200 mm bore 22 RM
156 44 Supply, fixing, jointing & testing Cast Iron Sluice Valve of sizes as under, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top including taking out unsv sluice valve complete all as specified and as directed.\nNote:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
157 44.01 100 mm bore 1 EACH
158 44.02 150 mm bore 2 EACH
159 45 Supply, fixing, jointing and testing of Cast iron Non Return valve without by pass arrangement, swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out unsv NRV complete all as specified and as directed. \nNote:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
160 45.01 100 mm bore 2 EACH
161 45.02 150 mm bore 2 EACH
162 46 Supply and fixing CI foot valve flanged ends, swing type opration with rubber sheet, as per IS:4038 including taking out unsv foot valve complete all as specified and as directed. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
163 46.01 100 mm bore 2 EACH
164 46.02 150 mm bore 2 EACH
165 47 Supply, installation and testing of flanged ends water meter ISI marked woltman type, Class 'B' of following sizes and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, including taking out unsv water meter complete all as specified and as directed. \nNote :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item.
166 47.01 100 mm bore 1 EACH
167 47.02 150 mm bore 1 EACH
168 48 Supply and fixing for mild steel work for manhole cover, stair case steps made of MS angle/ flats/channels etc including cutting out top and bottom to shape as directed, drilling holes, notching for wire etc flat iron fillets including all necessary drilling, bolting or rivetting etc and similar works confirming to Fe-290, Gde E-165 and applying two coats of synthetic enamel paint over a coat of red oxide primer including preperation after demolition of existing covers,steps etc complete all as specified and as directed. 240 KG
169 49 Material and labour for painting on steel and iron surfaces with one coat of synthetic enamel paint as per existing colour scheme or pattern after preperation of old painted surface of any description over 10cm in width or girth complete all as specified and as directed. 100 SQM
170 50 Multipurpose Grease lubricant for Motors & Pumps 5 KG
171 51 Supply and fixing in replacement LED batten arrow for multi application suitable for 18 Watts with & including necessary cable connection to make it functional complete all as specified and as directed. 10 NOS
172 52 Supply only the following items :-
173 52.01 Switch Piano flush type 5 amps single pole one way 240 volts 25 EACH
174 52.02 Switch Piano flush type 15 amps, single pole, one way 240 volts. 10 EACH
175 52.03 Switch Socket outlet 3 pin, 5 amps 240 volts 10 EACH
176 52.04 Switch Socket outlet 3 pin, 15 amps 240 volts 10 EACH
177 52.05 MCB SP 6 to 32 Amp, 240 Votls 10 EACH
178 53 An amount of Rs 64080.00 shall be deducted from BOQ on account of schedule of credit