Science and Technology Statutory Bodies & Commissions/Committees Closing in 0 days TDR #26530956

Design , Development And Supply Of Line Replacement Unit Of Fuel System For Tractor Aircraft With High Wing Mounted Pt6-67A Engine

Issued by Statutory Bodies & Commissions/Committees · CAD,CSIR-NAL,NWTC,BELUR,BLR, Karnataka
Tender Value
Ref. Documents
Estimated cost
Bid Submission
18 Feb 2021
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
CAD,CSIR-NAL,NWTC,BELUR,BLR → Karnataka
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Design , Development And Supply Of Line Replacement Unit Of Fuel System For Tractor Aircraft With High Wing Mounted Pt6-67A Engine , Fuel Booster , Booster Pump Pressure Switch , Jet Transfer Pump , Booster Pump Non Return Valve , Inward/Outward Relief Valve , Refuel/Defuel Valve , Single Refuel/Defuel Valve Connector , Refuel/Defuel Panel , Motorized Main Fuel Shut-Off Ball Valve , Fuel Filter , Filler Cap And Adapter , Collector Tank Flapper Valve , Capacitance Probes- Probe , Fuel Level , Collector +Lls+Es , Capacitance Probes-Probe , Fuel Level , Wing , Inner , Capacitance Probes- Probe , Fuel Level , Wing , Mid , Capacitance Probes- Probe , Fuel Level , Wing , Outer , Hls , Capacitance Probes-Probe , Fuel Level , Aux , Inner , +Hls , Capacitance Probes- Probe , Fuel Level , Aux , Outer + Es , Valve , Fuel , Drain , Magnastick , Wing , Inner , Magnastick , Wing , Outer , Magnastick , Aux , Motorized Cross Feed Shut-Off Valve For Cross Feed ( Line ) , Motive Flow Non-Return Valve , Drain Valves And Collector Dump , Vent Valve , Flame Arrestor , Fuel Flow Transmitter , Vent Tank Flapper Valve , Fuel Control Unit , Protection Boxes , Wet Cables , Mating Connectors , Fittings , Sub-Total:Ex-Works Price , Less: Discount ( If Any ) , Sub-Total: , Less: Buy-Back Price ( If Any ) , Sub-Total:Net Ex-Works Price , Add: Packing & Forwarding Charges ( If Any ) , Add: Transportation Charges ( If Any ) , Add: Insurance Charges ( From Warehouse-To-Warehouse ) ( If Any ) , Total ( A ) : , Installation & Commissioning Charges ( If Any ) , Training Charges ( If Any ) , Total ( B ) : , Bank Charges , If Any , Any Other Charges , If Any , Total ( C ) : , Amc Charges For 1St Year , Amc Charges For 2Nd Year , Amc Charges For 3Rd Year , Total ( D ) :

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 11-Feb-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-Feb-2021

BOQ

Name of Work: as per Tender Specifications & Terms
Sl. No.Item DescriptionItem Code / MakeQuantityUnits
11Fuel Booster24Nos
22Booster Pump pressure Switch12Nos
33Jet transfer Pump6Nos
44Booster Pump Non Return Valve24Nos
55Inward/Outward Relief Valve12Nos
66Refuel/Defuel Valve12Nos
77Single Refuel/Defuel Valve connector3Nos
88Refuel/Defuel Panel3Nos
99Motorized main fuel shut-off ball Valve6Nos
1010Fuel Filter6Nos
1111Filler Cap and Adapter12Nos
1212Collector tank flapper Valve18Nos
1313Capacitance Probes- Probe, Fuel Level, Collector +LLS+ES6Nos
1414Capacitance Probes -Probe, Fuel Level, Wing, Inner6Nos
1515Capacitance Probes- Probe, Fuel Level, Wing, Mid6Nos
1616Capacitance Probes - Probe, Fuel Level, Wing, Outer, HLS6Nos
1717Capacitance Probes -Probe, Fuel Level, Aux, Inner, +HLS6Nos
1818Capacitance Probes- Probe, Fuel Level, Aux, Outer + ES6Nos
1919Valve, Fuel, Drain36Nos
2020Magnastick, Wing, Inner6Nos
2121Magnastick, Wing, Outer6Nos
2222Magnastick, Aux6Nos
2323Motorized Cross Feed Shut-off Valve for cross feed(line)3Nos
2424Motive flow Non-Return Valve6Nos
2525Drain Valves and Collector Dump6Nos
2626Vent Valve6Nos
2727Flame Arrestor6Nos
2828Fuel flow Transmitter6Nos
2929Vent tank flapper valve6Nos
3030Fuel Control Unit6Nos
3131Protection boxes, wet cables, mating connectors, fittings3Set
3232Sub-Total:Ex-Works Price1Nos
3333Less: Discount (if any)1Nos
3434Sub-Total:1Nos
3535Less: Buy-back Price (if any)1Nos
3636Sub-Total:Net Ex-Works Price1Nos
3737Add: Packing & Forwarding charges (if any)1Nos
3838Add: Transportation Charges (if any)1Nos
3939Add: Insurance charges (from warehouse-to-warehouse) (if any)1Nos
4040Total (A):1Nos
4141Installation & Commissioning charges (if any)1Nos
4242Training charges (if any)1Nos
4343Total (B):1Nos
4444Bank Charges, if any1Nos
4545Any other charges, if any1Nos
4646Total (C):1Nos
4747AMC Charges for 1st Year1Nos
4848AMC Charges for 2nd Year1Nos
4949AMC Charges for 3rd Year1Nos
5050Total (D):1Nos

AI Tender Summary

OUR REF NO 26530956
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 18-02-2021
Authority
Authority Name Council Of Scientific And Industrial Research
Work Description Design , Development And Supply Of Line Replacement Unit Of Fuel System For Tractor Aircraft With High Wing Mounted Pt6-67A Engine , Fuel Booster , Booster Pump Pressure Switch , Jet Transfer Pump , Booster Pump Non Return Valve , Inward/Outward Relief Valve , Refuel/Defuel Valve , Single Refuel/Defuel Valve Connector , Refuel/Defuel Panel , Motorized Main Fuel Shut-Off Ball Valve , Fuel Filter , Filler Cap And Adapter , Collector Tank Flapper Valve , Capacitance Probes- Probe , Fuel Level , Collector +Lls+Es , Capacitance Probes-Probe , Fuel Level , Wing , Inner , Capacitance Probes- Probe , Fuel Level , Wing , Mid , Capacitance Probes- Probe , Fuel Level , Wing , Outer , Hls , Capacitance Probes-Probe , Fuel Level , Aux , Inner , +Hls , Capacitance Probes- Probe , Fuel Level , Aux , Outer + Es , Valve , Fuel , Drain , Magnastick , Wing , Inner , Magnastick , Wing , Outer , Magnastick , Aux , Motorized Cross Feed Shut-Off Valve For Cross Feed ( Line ) , Motive Flow Non-Return Valve , Drain Valves And Collector Dump , Vent Valve , Flame Arrestor , Fuel Flow Transmitter , Vent Tank Flapper Valve , Fuel Control Unit , Protection Boxes , Wet Cables , Mating Connectors , Fittings , Sub-Total:Ex-Works Price , Less: Discount ( If Any ) , Sub-Total: , Less: Buy-Back Price ( If Any ) , Sub-Total:Net Ex-Works Price , Add: Packing & Forwarding Charges ( If Any ) , Add: Transportation Charges ( If Any ) , Add: Insurance Charges ( From Warehouse-To-Warehouse ) ( If Any ) , Total ( A ) : , Installation & Commissioning Charges ( If Any ) , Training Charges ( If Any ) , Total ( B ) : , Bank Charges , If Any , Any Other Charges , If Any , Total ( C ) : , Amc Charges For 1St Year , Amc Charges For 2Nd Year , Amc Charges For 3Rd Year , Total ( D ) :
Basic Detail
Tender No NAL/PUR/CAD/321/20-Z
Bidding Type Tender
Location
City CAD,CSIR-NAL,NWTC,BELUR,BLR
State Karnataka
Key Dates
Publish Date 11 Feb 2021
Submission Date 18 Feb 2021
Open Date 19 Feb 2021
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
Tendernotice_1.pdf
Terms-and-Conditions-new.pdf
BOQ_71515.xls
552588FD-0692-491F-B947-BF35CF7FAF90.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 11, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 18, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 18, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 19, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

pdf

Terms-and-Conditions-new.pdf

xls

BOQ_71515.xls