Repairing Of Parks Including Jogging Track In E-Crescent Park At Malcha Marg Repair And Maintenance Of Infrastructure Assets In R-Iv Division During 2020-21 . Sub Head-Repairing Of Parks Including Jogging Track In E-Crescent Park At Malcha MargChankya, NDMC AREA-Delhi

New Delhi Municipal Council-NDMC has published Repairing Of Parks Including Jogging Track In E-Crescent Park At Malcha Marg Repair And Maintenance Of Infrastructure Assets In R-Iv Division During 2020-21 . Sub Head-Repairing Of Parks Including Jogging Track In E-Crescent Park At Malcha MargChankya. Submission Date for this Tender is 18-01-2021. Road Work Tenders in NDMC AREA Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

26529467
Repairing Of Parks Including Jogging Track In E-Crescent Park At Malcha Marg Repair And Maintenance Of Infrastructure Assets In R-Iv Division During 2020-21 . Sub Head-Repairing Of Parks Including Jogging Track In E-Crescent Park At Malcha MargChankya
Open Tender
Indian
Delhi
NDMC AREA
18-01-2021

Tender Details

Repairing Of Parks Including Jogging Track In E-Crescent Park At Malcha Marg Repair And Maintenance Of Infrastructure Assets In R-Iv Division During 2020-21 . Sub Head-Repairing Of Parks Including Jogging Track In E-Crescent Park At Malcha MargChankyapuri , New Delhi .

Key Value

Document Fees
Refer document
EMD
INR 7096.0 /-
Tender Value
INR 3.54 Lakhs /-

BOQ Items

Name of work:-Repair and Maintenance of Infrastructure Assets in R-IV Division during 2020-21. Sub Head:-Repairing of parks including Jogging Track in e-Crescent Park at Malcha Marg Chankyapuri, New Delhi.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Providing and laying at or near ground level factory made kerb stone\nof M-25 grade cement concrete in position to the required line, level\nand curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse\nsand), including making joints with or without grooves (thickness of\njoints except at sharp curve shall not to more than 5mm), including\nmaking drainage opening wherever required complete etc. as per\ndirection of Engineer-in-charge (length of finished kerb edging shall\nbe measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). BI01010001010000000000000515BI0100001113 10 m3
2 2 Earth work in surface excavation not exceeding 15 cm in depth but exceeding 1.5metre in width as well as 10 square metre on plan including getting out and disposal of excavated earth lead upto 50 metre and lift upto 1.5m as directed by Engineer-in-charge . 268.8 m2
3 3 Laying water bound macadam sub-base with brick aggregate and\nbinding material, earth etc. including screening, sorting and spreading\nto template and consolidation with light power road-roller etc.\ncomplete.(payment for brick aggregate and moorum etc. to be made\nseparately)\nOver burnt (Jhama) brick aggregate 90 mm to 45 mm 26.9 m3
4 4 Supplying and stacking at site.\nOver burnt (Jhama) brick aggregate 90 mm to 45 mm 26.9 m3
5 5 Supplying, stacking and Spreading 6 mm thick red bajri, watering\nand rolling complete including preparation of the surface and rolling.\nWith road roller/ hand roller 268.8 m2
6 6 Providing and spraying the specialized Organic solution of making the earthen walkway/soil stabilization / embankment preparation etc. to control dust and erosion of soil. The organic solution i.e Bug cement contain natural bacteria and microbial no bacillus pasteuri which is able to solidify soil . The recommended quantity should not be less than 10ml per square metre solution of Bug cement, 3% to maximum upto 5% with water for garden area as per the soil property and 30% moisture content to be maintained for minimum 10 days, optimize by using urea and jiggery as per desired quantity. The complete process taken 10 days including Bug cement spraying mechanically through specialized sparying machine and with continuous manpower to spray and monitor the dosage of water, Bug cement and moisture content. The good earth/ Screened soil shall be laid as per requirement. 268.8 m2
7 7 Brick work with common burnt clay F.P.S. (non modular) bricks of class\ndesignation 7.5 in foundation and plinth in:\nCement mortar 1:4 (1 cement : 4 coarse sand) 10 m3
8 8 Washed stone grit plaster on exterior walls height upto 10 metre\nabove ground level, in two layers, under layer 12 mm cement plaster\n1:4 (1 cement : 4 coarse sand ), furrowing the under layer with\nscratching tool, applying cement slurry on the under layer @ 2 Kg of\ncement per square metre, top layer 15 mm cement plaster 1:1/ 2:2\n(1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size),\nin panels with groove all around as per approved pattern, including\nscrubbing and washing the top layer with brushes and water to expose\nthe stone chippings ,complete as per specification and direction of\nEngineer-in-charge (payment for providing grooves shall be made\nseparately). 100 m2
9 9 Structural steel work in single section, fixed with or without connecting\nplate,including cutting, hoisting, fixing in position and applying a priming\ncoat of approved steel primer all complete. 500 kg
10 10 Welding by gas or electric plant including transportation of plant at\nsite etc. complete.\n\nConditions :-\n2.80 M.T. Cement in bags shall be arranged by the contractor himself and nothing extra shall be paid on this account. 3000 cm