Provision Of Toilet At Airmen Mess At Sub Unit C Of 42 Weu Lunglei Under Age I Af Kumbhirgram 3Rd Call
Tender Overview
Project Description
Provision Of Toilet At Airmen Mess At Sub Unit C Of 42 Weu Lunglei Under Age I Af Kumbhirgram 3Rd Call
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-Jan-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-Feb-2021 |
| 2 | 01-Feb-2021 | Corrigendum to dates | Date | 06-Feb-2021 |
BOQ
| NAME OF WORK : PROVISION OF TOILET AT AIRMEN MESS AT SUB UNIT 'C' OF 42 WEU, LUNGLEI UNDER AGE(I) (AF) KUMBHIRGRAM (3RD CALL) | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 0 | NOTE:-\n(i) Schedule 'A' Part I to VII are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. \n(ii) Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates | |||
| 2 | 1 | Total amount of Sch 'A' Part I (BUILDING WORK) \nConstruction of toilet block single storey building complete all as shown on drawings and as specified. | 1 | Each\nBlock\n | |
| 3 | 2 | Total amount of Sch 'A' Part-II (SITE CLEARANCE AND EARTH WORK). \nNote: Details of prepriced schedule are given in tender documents. | 1 | Lump sum | |
| 4 | 3 | Total amount of Sch 'A' Part-III (INTERNAL ELECTRICATION). \nNote: Details of prepriced schedule are given in tender documents. | 1 | Lump sum | |
| 5 | 4 | Total amount of Sch 'A' Part-IV (INTERNAL WATER SUPPLY). \nNote: Details of prepriced schedule are given in tender documents. | 1 | Lump sum | |
| 6 | 5 | Total amount of Sch 'A' Part-V (EXTERNAL WATER SUPPLY) \nNote: Details of prepriced schedule are given in tender documents. | 1 | Lump sum | |
| 7 | 6 | Total amount of Sch 'A' Part-VI (SEWAGE DISPOSAL) Note: Details of prepriced schedule are given in tender documents. | 1 | Lump sum | |
| 8 | 7 | Total amount of Sch 'A' Part-VII (AREA DRAINAGE ) Note: Details of prepriced schedule are given in tender documents. | 1 | Lump sum | |
| 9 | 8 | Sch 'A' Sec -VIII (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col 5 signifies this fact only. | |||
| 10 | 8.01 | S&F CP angle cock with flange all as specified and as directed.\nMake:Jaquar/Kohler/Grohe/Prayag/Essco\n | 6 | Each | |
| 11 | 8.02 | S&F surface and wall mounted LED 20 watts, batten light fitting including tube extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver with all accessories and including connecting up with twin core copper conductor with suitable size complete all as specified and directed.\nMAKE- Havells Cat Part No. LHEWEBP5IN1W020 or equivalent model of make Wipro/Bajaj/ Surya/ Phillips/Crompton.\n | 5 | Each | |
| 12 | 8.03 | S&F surface and wall mounted LED 9 watts, batten light fitting including tube extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver with all accessories and including connecting up with twin core copper conductor with suitable size complete all as specified and directed.\nMAKE- Havells Cat Part No. LHEXBQP5IN1W009 or equivalent model of make Wipro/Bajaj/ Surya/ Phillips/Crompton.\n | 2 | Each | |
| 13 | 8.04 | S&F high performance metal body exhaust fan 300 mm sweep, 1400 RPM 240 volts AC 50 Hz, heavy duty with suitable size MS sheet louver including connecting up to ceiling rose by three core sheathed copper conductor cable of suitable size including making good the disturbed surface to its original specification from both inner and outer side of wall and four Nos suitable size nuts, bolts and washer with proper grouting in wall complete all as specified and directed.\nMake :- USHA: Model No. Aeroclean LD DBB (Anti dust) or equivalent model of make Bajaj/Havells.\n | 4 | Each | |
| 14 | 8.05 | S&F MCB SPN 6 to 32 Amps, 230 volts, 10 KA breaking capacity complete all as specified and directed. | 2 | Each | |
| 15 | 8.06 | S&F MCB SP 6 to 32 Amps, 230 volts, 10 KA breaking capacity complete all as specified and directed. | 1 | Each | |
| 16 | 8.07 | Construction of Septic tank of 10 users including necessary excavation and earth work in soft/ loose soil, PCC foundation of 1:2:4, brick work in CM 1:4 and RCC cast-in situ slab etc, complete all as specified in drawing and as directed. | 1 | Each | |
| 17 | 8.08 | Construction of Soakage well of size 1.2m dia and 3.0m depth including necessary excavation and earth work in soft/ loose soil complete all as per drawing and as specified | 1 | Each |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender