| 1 | 1 | Appendix - A : Building Proper | BI01010001010000000000000515BI0100001113 | | |
|---|
| 2 | 1.01 | od63642/2019_2020 : Providing and fixing Sun control film coatings on glass (Frosted/Black) including all cost of materials and labour charges etc complete and as per the direction of the Engineer in charge. | BI01010001010000000000000515BI0100001114 | 18.27 | sqm |
|---|
| 3 | 1.02 | 15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below | BI01010001010000000000000515BI0100001115 | 7 | each |
|---|
| 4 | 1.03 | 15.23.2 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm | BI01010001010000000000000515BI0100001116 | 220 | sqm |
|---|
| 5 | 1.04 | 15.2.1 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) | BI01010001010000000000000515BI0100001117 | 2.8 | cum |
|---|
| 6 | 1.05 | 13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand) | BI01010001010000000000000515BI0100001118 | 76.32 | sqm |
|---|
| 7 | 1.06 | 22.6 : Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) | BI01010001010000000000000515BI0100001119 | 333.385 | sqm |
|---|
| 8 | 1.07 | od70066/2019_2020 : providing and laying 4mm thick epoxy flooring after cleaning the surface and grinding is carried out if required to make the surface rough in order to enhance the bonding of the primer.Then the surfacewill be allowed to dry till it is borne dry.Undulations, holes if any will be evened out by epoxy putty.The prepared surface will be then coated with one coat of water/epoxy based epoxyprimer Flowprime.Over this will be provided 4mm thick self levelling epoxy screed Florgard SL a three component solvent less epoxy resin composition of base hardening and hardner ,hard wearing quartz fillers and topping.The final finish will be smooth attractive hygenic hard wearing, chemical resistant floor topping and the work done by approved agency | BI01010001010000000000000515BI0100001120 | 169.14 | sqm |
|---|
| 9 | 1.08 | od70068/2019_2020 : prpviding Epoxy coving to 90 degree wall to floor cavings with corrosid EF epoxy morttar (50 cm on walls and 50 cm o floor) | BI01010001010000000000000515BI0100001121 | 300 | metre |
|---|
| 10 | 1.09 | od23833/2020_2021 : Providing and installing Antistatic & Antibacterial Vinyl sheet (Tarkette/Gerflor/Polyflor or equivant ) Flooring including skirting with conductive backing to OT`s ,1.83mtr wide and 16mtr long, having a nominal total thickness of the wear layer would be 2.2mm meeting EN 685 standards. The Slip Resistance should meet the BGR 181 Standards R10 group and should pass the DOP Content test(standard- EN15777). The Flammability tests to meet EN 13501-1 standards. The impact sound reduction should be 3dB(EN ISO 140-8 standards) . The wear resistance should be tested as per EN 649 and and should come under the P Group criteria.The colour fastness should be tested in according to ISO-105 B02 and should be rated >6. The thermal resistance should be according to EN12667 and thermal conductivity according to EN12524 standards. The static electrical charge-System Test should meet EN61340-4-5 standards(<100 Volts) and static electrical charge should meet EN1815(<2.0kV). The electrical insulation to ground should meet VDE0100 >50 kOhm.installation : It is important to ensure the sub floor on which the sheet is being laid is smooth, flat &hard & free from moisture, grease, etc.In case of uneven sub floor the same should be levelled by self levelling compound and coved using pvc cove fillets . The moisture level present in the sub floor should be less than 8% before installation of the floor.The installation shall be undertaken as per the manufacturer’s installation instructions | BI01010001010000000000000515BI0100001122 | 386.255 | sqm |
|---|
| 11 | 1.1 | od28241/2020_2021 : PPGI Panel 50mm thick with 0.8mm GI on the front and 0.5mm on the back side sandwitched with infill puff having density of 40kg/cm3.Designed in such a way to avoid the 90 degree corners as per NABH standard in Hexagonal design. | BI01010001010000000000000515BI0100001123 | 401.275 | sqm |
|---|
| 12 | 1.11 | od63655/2019_2020 : Filling of all joints and cavities with metallic epoxy filler and sanded flush to provide a jointless finish and spraying with anti becterial, self sterilizing paint to a d.f.t. of 300micron with primer | BI01010001010000000000000515BI0100001124 | 200 | sqm |
|---|
| 13 | 1.12 | od63656/2019_2020 : Supply and installation of Puff panels for providing partition in OTs. 50mm thick PUF infilled between two layers of 0.8mm thick PPGI sheet on both side having density of 40Kg/m3 with proper supports. | BI01010001010000000000000515BI0100001125 | 922.8 | sqm |
|---|
| 14 | 1.13 | od66205/2019_2020 : Supplying and fixing double glazed, vacuum sealed UPVC window in two partition using 60x55mm for outer frame and 74 x 60mm for mullion, 34x20mm glazing bead and gaskets of TPV prefixed to the frame before fabrication and the outer frame and mullion are reinforced with GI sheet of 28x20x1.50mm and 23x31x1.50mm respectively and with 5mm plain toughened float glass out side and inside, air gap of 12mm including fixing to the openings in the wall with suitable fastners etc complete | BI01010001010000000000000515BI0100001126 | 33.92 | sqm |
|---|
| 15 | 1.14 | od63660/2019_2020 : Supplying and fixing Hermetically sealed single leaf manual sliding door : (Metaflex brand or equivalent) Product Description : HPL finish PUF infil - Size: 1800mm x 2400mm , with clear opening of 1680mm X 2400mm, with lever handle both side for manual opening, view glass of 300mm X 300mm. Door profile - Heavy duty extruded single length Aluminium Alloy profiles (3.2 Kg / m) in 6063 T6 grade with unique indentations that allow the door to slide “down and in” (6mm down and 6mm in) simultaneously at an angle of 45° utilizing the weight of the door to give a perfect hermetic sea Grade 6063, Temper T6.Natural Anodised 20 μm as per EN ISO 2360. Lever Handle - Solid AISI 304 Grade Stainless Steel, Rubber spring system. Rail - Aluminium Alloy, Grade 6063, Temper T6 Natural ns | BI01010001010000000000000515BI0100001127 | 5 | no |
|---|
| 16 | 1.15 | 15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar | BI01010001010000000000000515BI0100001128 | 16.08 | cum |
|---|
| 17 | 1.16 | od28263/2020_2021 : Two station Foot operated Surgical Scrub Sink made out of 1.2 mm Stainless Steel of SS 304 Grade welded construction to get the seamless finish with 2 Nos Foot Operated Taps and Soap Dispensers. | BI01010001010000000000000515BI0100001129 | 5 | no |
|---|
| 18 | 1.17 | od28267/2020_2021 : Double Glazed View Glass Panel of Size 4ft x 5ft with 25mm Spacer Sandwitched with 4mm Glass. | BI01010001010000000000000515BI0100001130 | 5 | no |
|---|